HomeMy WebLinkAboutB13-0501 Carolyn Godfrey From: Martin Haeberle Sent: Monday, January 06, 2014 8:37 AM To: Carolyn Godfrey Subject: FW:Vail International Building 008 Attachments: Permit release letter.doc From: Patrick Hoeft fmailto:patrickCc�hoeftbuilderswest.co� Sent: Monday, December 30, 2013 7:42 AM To: Martin Haeberle; JR Mondragon Subject: Vail International Building 008 Dear Martin and 1R, I have attached the following letter for a request to transfer a submitted permit. I am no longer going to be the General Contractor representing the owner. He will be submitting under his name. Please call me or email me once received. Thanks PATRICK J. HOEFT PRESIDENT 970-904-1959 CELL ' BUILDERS WEST INC. , � i� ��«.�����a � ��-. ATTN: Martin Haeberle Chief Building Official Community Development Department 75 South Frontage Road Vail. Colorado 81657 Dear Mr. Haeberle, This letter is for the request of transferring the permit submitted under Hoeft Builders West (license # ) to Mr. Ricardo Tabet. This permit was submitted back in November of 2013 for the Vail International Building, (300 East Lionshead Circle unit 008). The owner wishes to submit under his name, Ricardo Tabet, and Hoeft Builders West is no longer the acting General Contractor. Respectfully Submitted, Patrick Hoeft President/Owner PO Box6332 Avon, CO 81620 970-904-1959 patrick@hoeftbuilderswest.com _ Carolyn Godfrey From: Carolyn Godfrey Sent: Monday, January 06, 2014 8:51 AM To: patrick@hoeftbuilderswest.com Subject: B13-0501 Dear Mr. Hoeft, Regarding your below email: From: Patrick Hoeft jmailto:patrickCc�hoeftbuilderswest.com] Sent: Monday, December 30, 2013 7:42 AM To: Martin Haeberle; JR Mondragon Subject: Vail International Building 008 Dear Martin and JR, I have attached the following letter for a request to transfer a submitted permit. I am no longer going to be the General Contractor representing the owner. He will be submitting under his name. Please call me or email me once received. Thanks PATRICK J. HOEFT PRESIDENT 970-904-1959 CELL II BUILDERS WEST INC. Please have Mr. Ricardo Tabet contact the Town of Vail Community Development Department regarding his permit (613-0501). This permit was approved on November 11,2013. Mr.Tabet has 180 days from November 11,2013 in which to assign another Registered General Contractor and pay the remaining balance of$3,040.00 before this permit expires. He may also contact Mr. Martin Haeberle(mhaeberle@vail�ov.com or tel: 970-479-2142) before the 180 days has elapsed and request an extension for this permit. Otherwise,the permit will expire and the fees already paid ($746.94)will be forfeited and he will have to re-apply for a new permit. Please have Mr. Ricardo Tabet contact us as soon as possible. Thank you. 1 Department of Community Development 75 South Frontage Road Vait, CO 81657 TOWN OF VAlL � �� Tel: 970-479-2128 www.vaiigov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project#: ��J f "> ���� �_ E L►oNh �M .i/� I1 � DRB#: ._. - (Number) (Street) (Suite#) C Ir Building Permit#: �` 3��J� ( Building/Complex Name: V�,� �v��1/NMf�a���+ � � ��� Contractor Information Lot#: � Block# � Subdivision: Business Name: ��t D����1.��?W�`�� ,�� �---- P �����2� Work Class: New( ) Addition ( ) Alteration �) Business Address: e 7 /� Type of Building: City tt(jQ�.. State:�_Zip: /� Single-Family( ) Duplex( ) Multi-Family(�() Contact Name: Yh�v«�NI���' Commercial ( ) Other( ) Contact Phone: q��' ��`��� L/� . k ��n} �N�'�,�. �{� ��� Work Type: Interior(� Exterior( ) Both( ) Contact E-Mail:Pafiv►� t . Valuation of I hereby acknowledge that I have read this application,filled out �I�/ork Included Plans Included Work in full the information required,completed an accurate plot plan, _ __ and state that all the information as required is correct. I agree to Elecfncal (�Yes ONo OYes ( �No comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to Mechanical ( )Yes (�No ( )Yes (�()No the town's zoning and subdivision codes, design review ap- �— proved, International Building and Residential Codes and other Plumbing (�()Yes ( )No ( )Yes (x)No ordinances of own applicable thereto. guilding (�)Yes ONo �jYes ONo ���� _ � X _ Value of all work being performed: $ IOO���� i Owner/Owner s Representative Signature(Required) ,( value based on IBC Section 109.3&IRC Section 108.3) � Electrical Square Footage __.. _ _..._. Applicant Information Detailed Scope and Location of Work: ApplicantName: Cr,.�y�� � � � �N���iy.l Ktuu•��('� r��'�f^"'" Applicant Phone: '7�u� ���� r� [�� � �� �t`N I�� Applicant E-Mail:�nir '..L� � w`t ����{�i �kt• �Olnn ` ` J Project Information I L Q�� bd���/1 tM �1,'� � �� )N tdnd / OwnerName: '(�N�[��� �a1P17 �u��,� �1D�N11 IAMVI'� Parcel#:� D O�� (For Parcel#,contac Eagle County Assessors Office at(970-328-8640 or visit www.ea g I eco u nty.us/pati e) (use additional sheet if necessary) For Office Use Only: �1 t,y Date Received: � � � � � � � Fee Paid: � I �� R 1 � Received From: Cash Check# � NOV � �� 2��3 CC: Visa/ MC Last 4 CC# exp date: 1 - A"tn # a T�WIV �F �Pel� �r�=_s— ---- — .�. K2013-Feb 01 ******************************************************************************************** TOWN OF VAIL, COLORADO Statement *******+***********************«***�********************++****************************+***** Statement Number: R130001886 Amount: $746. 94 11/04/201311:44 AM Payment Method:Credit Crd Init: CG Notation: visa patrick j hoeft ----------------------------------------------------- Permit No: B13-0501 Type: COMBINATION BLDG PERMIT Parcel No: 2101-064-0200-8 Site Address: 300 E LIONSHEAD CR VAIL Location: Unit 8 Total Fees: $3, 775. 69 This Payment: $746. 94 Total ALL Pmts: $746. 99 Balance: $3, 028 .75 ********************************+******************+*****************+********************** ACCOUNT ITEM LIST: Account Code Description Current Pmts ------------------------ PF 00100003112300 PLAN CHECK FEES 746. 94 ------------------------------------------------------ J �' ' . Project Name: Vail International Bulding-Unit 008-Electrical Service Size B : L le Pro'ect Solutions Date: 10/31/2013 NEC 2011 -Article 220-Part IV-Optioni Feeder and Service Code Reference: Load Calculations Service Voita e: 240 Phase: 1 Area SF : 915 Electrical Service Sizing General Loads Area VA 1 ft' Percent Load(VA) Commenta Generai Li hting and Receptacles 915 3 100% 2,745 NEC 220-82(B)(1 Appliances VAl Percent Load A) Comments Small Appliance Branch Circuit 2 1500 100°k 3,000 NEC 220-82(B)(2 Laund Branch Circuit 1 1500 100% 1,500 Other-Namplate Ratin s Qty VAIA p Percent Load(VA► Comments Washin Machine 1 1440 100°k 1,440 NEC 220-82(B)(3} Clothes D er 1 5760 100% 5,760 Dishwasher 1 1440 100% 1,440 Electric Cooktop 1 7680 100% 7,680 Downdraft Recirc Hood 1 1440 100% 1,440 Convection Oven 1 5760 100% 5,760 Speed Oven 1 3840 100% 3,840 Warmin Drawer 1 1440 100% 1,440 Warmin Drawer 1 1440 100% 1,440 Whole Bean Coffee Maker 1 1440 100°k 1,440 Refti eratorandFreezer 1 1920 100% 1,920 Garbage Disposai 1 1000 100% 1,000 Domestic Water Heater 1 4500 100°� 4,500 Motors VAIApp Percent load(VA) Comments N/A 0 0 100% - NEC 220-82(B)(4) Sub-totai All General Loads 46,345 10000 100°� 10,000 First 10kVa at 100�0 36345 40% 14,538 Remainder at 40°l0 Total General Loads 24,538 HVAC Loads VAIApp Porcent Load(VA) Comments Electric Baseboard 1 8000 40°/a 3,200 NEC 220-82(C)(5) otal H A oads 3, 0 ervice ze Total Loads 27,738 Amps 115.6 xisting ervice ize 150.0 J. ' � Appliance List Make Model Description v A W �B Meile W3037 Washing Machine 120 12 1440 15 Meile T8003 Clothes Dryer 240 24 5760 30 Meile G5615 sci Dishwasher 120 12 1440 15 Meile KM5840 3(Electric Cooktop 240 32 7680 40 Meile DA6480 Downdraft Recirc Hood 120 12 1440 15 Meile H4886 BP Convection Oven 240 24 5760 30 Meile H4086 BMI Speed Oven 240 16 3840 2� Meile ESW4086-Warming Drawer 120 12 1440 15 Meile ESW4086-Warming Drawer 120 12 1440 15 Meile CVA 4062\Whole Bean Coffee Maker 120 12 1440 15 GE Monogram ZIC30GRD Refrigerator and Freezer 120 16 1920 20 Garbage Disposal 120 Electric Baseboard Lighting Water Heater