HomeMy WebLinkAboutB13-050911 -10 -2014 Inspection Request Reporting Page 8 4:11 pm Vail, CO - City Of Requested Inspect Date: Tuesday November 11, 2014 Site Address: 83 WILLbW PL VAIL RIVERHOUSE UNIT 1 A /P /D Information Activity: 613 -0509 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occu ancyy: Use: Insp Area: Owner: KRAMER FAMILY TRUST SETTLEMENT OF TRUST Contractor: COMMERCIAL & RESIDENTIAL Phone: 970 - 688 -1872 CONSTRUCTION LLC Description: REPLACE KITCHEN CABINETS, REPLACE ELECTRICAL PANEL, REPLACE EXISTING CAN TRIMS, ADD UNDERCABINET LIGHTING, SKIM WALLS AND PAINT. Item: ,80 BLDG -Final 688 -1872 JMONDRAGON Insaection Histo Requested Time: 01:30 PM L Phone: 970 - 688 -1872 Time Exp: Entered By: JMONDRAGON K Item: 120 ELEC -Rou h *' Approved *' 12/11/13 Inspector: sgremmer Comment: Item: 220 PLMB - Rough /D.W.V. *" Approved " 12/12/13 Inspector: sgremmer Comment: Item: 230 PLMB- Rough/Water '" Approved *' 12/12/13 Inspector: sgremmer Comment: Item: 60 BLDG - Sheetrock Nail Item: 70 BLDG -Misc. Item: 190 ELEC -Final '* Approved ** 12/26/13 Inspector: sgremmer Comment: Item: 290 PLMB -Final ** Approved'* 12/26/13 Inspector: sgremmer Comment: Item: 90 BLDG -Final 06/27/14 Inspector: Martin Comment: Unable to gain access Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: DN DENIED REPT131 Run Id: 14829 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MA OVO Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B13 -0509 Project #: PRJ13 -0684 Job Address: 83 WILLOW PL VAIL Applied.....: 11/07/2013 Location......: RIVERHOUSE UNIT 1 Issued...: 11/2512013 Parcel No....: 210108216001 OWNER KRAMER FAMILY TRUST SETTLEME 11/07/2013 4912 HARVERWOOD LN APT 311 DALLAS, TX 75287 APPLICANT COMMERCIAL & RESIDENTIAL CON 11/07/2013 Phone: 970 - 688 -1872 MATTHEW BOMER PO BOX 273 VAI L CO 81658 License: C000003222 CONTRACTOR COMMERCIAL & RESIDENTIAL CON 11/07/2013 Phone: 970 - 688 -1872 MATTHEW BOMER PO BOX 273 VAI L CO 81658 License: C000003222 Description: REPLACE KITCHEN CABINETS, REPLACE ELECTRICAL PANEL, REPLACE EXISTING CAN TRIMS, ADD UNDERCABINET LIGHTING, SKIM WALLS AND PAINT. Occupancy: Type Construction: Valuation: $16,700.00 FEE SUMMARY Building Permit ------ - - - - -> $279.25 Bldg Plan Check ----- - - - - -> $181.51 Use Tax Fee------------------ - - - - -> $134.00 Electrical Permit ---- - - - - -> $115.00 Elec Plan Check ------ - - - - -> $74.75 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $15.00 Plmb Plan Check ---- - - - - -> $3.75 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $15.00 TOTAL PERMIT FEES--------- - - - - -> $818.26 Payments ------------------------------- > $818.26 BALANCE DUE ------------------------ > $0.00 DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit_012811 NOViAIL ##### rtfirtxx*###### rtxxx*#* x## rt# rtfixfix***##### rtrtrtxfi*#### xrtfififix*###* rt# fififi* x**## x# rtrtxx**#### rtxxx**#**# rtrtrtrtrtrtx###*# x## rtrt x** xx**## rtrtfi x* xx*#### rt. fi*****## rtrtxfixxxxx #rtrtfixxxfix *x #firtfifixxx #xxrtrtfixxx CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B13 -0509 Address: 83 WILLOW PL VAIL Owner: KRAMER FAMILY TRUST SETTLEMENT OF TRUST Location: RIVERHOUSE UNIT 1 x*#*## rtrtrtxxrtx#*### rtrtxfixxx***#### rtrtfififixfi##*##*# rtrtxfix**#**# rtrt# fifififix###### xfififi*##### rt# fixfifi#*## rtrtfixxx######## rtrtxxfi**##### rtrtrtrtx # # * # # # #rtrtxxx # * # ## #rtrtrtfi *x * # * ## #fifi * # *# # # # ** *fifi * * * * #firt * * * * # # *# combination permit-012811 W N 0.) FP OVAKII L REQUIRED INSPECTIONS AND STATUSES Permit #: B13 -0509 Address: 83 WILLOW PL VAIL Owner: KRAMER FAMILY TRUST SETTLEMENT OF TRUST Location: RIVERHOUSE UNIT 1 Item: 00120 ELEC -Rough Item: 00220 PLMB- Rough /D.W.V. Item: 00230 PLMB- Rough/Water Item: 00060 BLDG - Sheetrock Nail Item: 00070 BLDG -Misc. Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADOCopy Reprinted on 11 -25 -2013 at 10:03:54 11/25/2013 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: 8130002022 Amount: $503.65 11/25/201310:03 AM Payment Method: Check Init: DR Notation: CK# 1510 CRC DESIGN ----------------------------------------------------------------------------- Permit No: B13 -0509 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 082 - 1600 -1 Site Address: 83 WILLOW PL VAIL Location: RIVERHOUSE UNIT 1 Total Fees: $818.26 This Payment: $503.65 Total ALL Pmts: $818.26 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 279.25 EP 00100003111100 ELECTRICAL PERMIT FEES 75.40 UT 11000003106000 USE TAX 4% 134.00 WC 00100003112800 WILL CALL INSPECTION FEE 15.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 11 -07 -2013 at 16:37:35 11/07/2013 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R130001924 Amount: $314.61 11/07/201304:36 PM Payment Method: Check Init: DR Notation: CK# 1495 CRC DESIGN AND REMODEL ----------------------------------------------------------------------------- Permit No: B13 -0509 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 082 - 1600 -1 Site Address: 83 WILLOW PL VAIL Location: RIVERHOUSE UNIT 1 This Payment: ACCOUNT ITEM LIST: Account Code ----------------- EP 00100003111100 PF 00100003112300 PP 00100003111100 Total Fees: $818.26 $314.61 Total ALL Pmts: $314.61 Balance: $503.65 Description Current Pmts - -- ------------------------ - - - - -- ------ - - - - -- ELECTRICAL PERMIT FEES 39.60 PLAN CHECK FEES 260.01 PLUMBING PERMIT FEES 15.00 Department of Community Development 75 South Frontage Road TOWN OF VAIL Vail, CO 81657 Tel: 970 -479 -2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Mdress: (Number) (Street) / (Suite #) Building /Complex Name: T111o°�/� li Contractor Information Business Name: �� e & i a 4' r< Business Add1ress:U City I/, , 1 State: lU Zip: (G O Project #: U" #-�,J I �) DRB #: Building Permit #: I � J D-itA Lot #: a Block #-(.a- Subdivision: U V Work Class: New a Addition 0 Alteration 0 Type of Building: JJ Single- Family Contact Name: 1 CM3 I:T FAG /�, -�nZ Commercial y 1 Contact Phone: 1 ) d -!a &a 1t� Duplex 0 Multi - Family Other Contact E -Mail: N 4 tLJ C r c-v 4ik e t Work Type: Interior* Exterior Q Both O I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivisi n codes, design review ap- proved, IntematipKal Building.,drid Residential Codes and other ordinances of e Town livable thereto. X Owner /Owner's Representative Signature (Required) Applicant Information r Applicant Name: _S e �fAM�iL Applicant Phone: Zo,�-G Applicant E -Mail: -�L' Cck,tnJ Project Information _ Owner Name: ) c CC V r A e, �h Parcel #: .t I U [ /l IF d L GO C-4 J 1 (For Parcel #, contact Eagle County Assessors Office at (970328 -8640 or visit www.eag lecounty. us /patie) For Office Us nly: Fee Paid: 31 q, 61 Received From: _C R•C S 1 C 11100�L Cash Check # / S CC: Visa / MC Last 4 CC # exp date: Auth # Valuation of Work Included Plans Included Work Electrical ®Yes ONO IOYes ®jNo Mechanical OjYes Wo OjYes (DNo Plumbing qW O)No O)Yes O)No Building *Yes ONO Wes 0NNoo� %. Value of all work being performed: $ vCvC, 0 (ot ` r1 D0 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage Detailed Scope and Location of Work: C-e— 1`, kl ,o z_"ab,, , (use additional sheet if necessary) Date Rec : V P F. R W 9 D NOV 0 7 2013 TOWN OF VAIL I15- Mar -2012 LaVenture Engineering Associates, Inc. P. O. Box 11. Avon, CO 81620 tiv @centurytel.net Tel 970 390 -1984 November 3, 2U13 Thomas W. LaVenture CRC Design + Remodel Matt Bomer 970.935.3164 Re: Remodel — Electrical load center replacement 83 Willow Pl. Unit #1 Vail, CO Hi Matt, Attached please find the unit load calculation and 1 -line fault current model for the dwelling unit #1 at the River House condominiums, 83 willow Pl Unit #1. I have confirmed the characteristics of the electrical supply with the serving utility and the documentation requirements for the Town of Vail Department of Community Development. I have reviewed the building electrical service and unit distribution equipment to create the attached fault current model. Specific details of the actual service construction were not obtainable at the time of my site visit so the attached model represents a "worst - case" model for fault current. Actual fault currents will be less than shown in the attached model. The existing Unit #1 feeder conductor characteristics limit the load capacity of the unit so the replacement circuit breaker load center should be of similar characteristics to the existing panel - 100 amp rated with a fault current rating of not less than 10,000 amps. As such, there is little capacity to add additional loads to the unit in the future without further analysis. It is incumbent upon the electrical contractor to verify the temperature ratings of the existing unit feeder conductors are appropriate for the installation and load. The attached analysis is based on the following information: Feeder Voltage: 120/208 VAC Unit Feeder Loads: Electric heating - NO Hot -tub - NO Electric water heater - NO Boiler - NO The building was built in 1972 Laundry - NO Pumps - NO The branch circuits are copper conductors Disposal - YES Air Conditioning - NO The feeders conductors are #1 aluminum Microwave - YES Electric Demand Water Heater - Refrigerator - YES NO Wine Cooler - YES Hydro massage bathtub - NO Electric Range - YES Garage — NO Please call if you require additional information or if I can provide any other assistance. Best regards, Thomas LaVenture P.E. 970.390.1984 •. .PSYJ. Latr�Z•�p�0 :X 26749 M 2013 -11 -03 11:08 -07:00 83 Willow Pl. Unit #1 'W_/ONACE Page 1 of 3 PREPARED FOR: CRC Contractors 83 WILLOW PL. #1 UNIT FEEDER LOAD CALCULATION LAVENTURE ENGINEERING ASSOCIATES, INC. 70.6AMPrRES 83 Willow PI. #1 November 2, 2013 16954.25 VOLT -AMPS 9:39:36 AM LIGHT 4501.5 RANGE 8000 DRYER 0 FIXED ARPLIANCES 4,236.8 RECEPTACLES 0 HEAT 0 70.6 AMPS 240 VAC 1 PHASE SNOW MELT 0 16954.3 216.0 25% LARGEST MOTOR 1 216 16,738.3 SUB -TOTAL - VOLT -AMPS OAD 4501.5 8000 0 4,236.8 0 DIVERSITY 62% 67% 100% 75% 100% 125°/ 7290 12000 0 5649 0 08 W Zt7Z J Z a �0a c�Q ZW :10 Z 3� o Zm uj J 3� 0 ► + z L) J W a CL �" It o Q z J D W 3.1� C z J �� c U W U) 0 930 TOTAL SQUARE FOOTAGE 0 3 LIGHTING WATTS PER SQUARE FOOT 2790 2790 LIGHTING WATTS 0 0 1500 1500 SMALL APPLIANCE BRANCH CIRCUIT #K1 -1 1500 1500 SMALL APPLIANCE BRANCH CIRCUIT #K1 -2 1500 1500 SMALL APPLIANCE BRANCH CIRCUIT #K1 -3 0 0 LAUNDRY BRANCH CIRCUIT 0 12000 12000 COOKING UNITS NOT MORE THAN 12 kVA EACH 0 0 0 0 DRYER CIRCUITS @ 5000 VA EACH (ALLOWANCE) 0 0 0APPLIANCES FIXED IN PLACE 600 600 WINE CHILLER 0 BOILER 0 CIRCULATION PUMP 0 CIRCULATION PUMP 0 HYDROMASSAGE BATHTUB 0 HYDROMASSAGE BATHTUB 1150 1150 FRIDGE - KITCHEN 1110 1110 DISH WASHER 0 DISH WASHER 1800 1800 MICROWAVE 864 864 WASTE DISPOSER 0 OPENER 0 OPENER 0 GARAGE UNIT HEATER 0 water heater / 125 125.0 EXHAUST FANS O •• F ••'. 0 O F 01 IRRIGATION 0 STEAMER 0 EXISTING SPA 0 RECEPTACLES OTHER THAN GENERAL LIGHTING ' 0 • 0 'UNAL 0 ELECTRIC HEAT 0 0 ROOF SNOW MELT UNIT FEEDER LOAD CALCULATION LAVENTURE ENGINEERING ASSOCIATES, INC. SERVICE CONDUCTORS UNKNOWN. *FOR FAULT CURRENT CALCULATION - USE SERVICE CONDUCTORS SIZED FOR SERVICE CAPACITY AND 3% VOLTAGE DROP 2 - PARALLEL RUNS OF 500 KCMIL AL /PVC 150 FEET METER STACK SERVICE DISCONNECT 400 AMP 3 PHASE Pp0 REG /S O. ASP F,G� .FQ i 26749 G fir. 0;0NAU EN UTILITY DISTRIBUTION UTILITY TRANSFORMER HOLY CROSS ELECTRIC 300 KVA 208Y120 2.1% IMPEDANCE 41000 AIC PER HCE 16628LA KA MAX. I(SCA)* HOUSE SERVICE DISCONNECT 200 AMP 3 PHASE UNIT FEEDER #1 AL / EMT 60 FEET 5.6 KA MAX I(SCA)* UNIT LOAD CENTER 100 AMP 10 KAIC RATED MIN. FAULT CURRENT MODEL NOV 1, 2013 83 WILLOW PL. VAIL, CO UNIT #1 LAVENTURE ENGINEERING ASSC. INC. CRC CONTRACTORS THOMAS LAVENTURE P.E.