02-17-2014 Inspection Request Reporting Page 12
4:10 pm Vail, CO - City O (? 0 dog CP
Requested Inspect Date: Tuesday,February 18,2014
Site Address: 241 E MEADOW DR VAIL
A/P/D Information
Activity B13-0512 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type Occupancy: Use: Insp Area:
Owner TOWN OF VAIL
Contractor: A.K.ELECTRIC Phone: 970-376-8165
Description: Colorado Ski Museum-Install Lighting
Requested Inspection(s)
Item 90 BLDG-Final Requested Time: 10:00 AM
Requestor Phone:
Comments follow up
Assigned To JMONDRAGON Entered By: JMONDRAGON K
Action Time Exp:
Inspection History
Item 120 ELEC-Rough
Item 190 ELEC-Final
Item 90 BLDG-Final
REPT131 Run Id: 14741
�+.r•
NOTE:' THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
,.
TOWN OF YAQ,''•
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B13-0512
Project #: PRJ13-0686
Job Address: 241 E MEADOW DR VAIL Applied.....: 11/08/2013
Location......: Issued. . . : 11/19/2013
Parcel No....: 210108227002
OWNER TOWN OF VAIL 11/08/2013
75 S FRONTAGE RD
VAIL, CO
81657
CONTRACTOR A.K. ELECTRIC 11/08/2013 Phone: 970-376-8165
JOHN TOWNSEND
PO BOX 6241
AVON
CO 81620
License: C000003151
Description:
Colorado Ski Museum - Install Lighting
Occupancy: Type Construction: Valuation: $39,500.00
.....,,.................>.....,.,........,...,....,,........,,,�.................... FEE SUMMARY .....,_.............,..................,...................,........,.,,.....,...
Building Permit-----------> $542.75 Bldg Plan Check----------> $352.79 Use Tax Fee-----------------------> $590.00
Electrical Permit---------> $1,265.00 Elec Plan Check-----------> $822.25 Restuarant Plan Review--------> $0.00
Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $1,490.54)
Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $5.00
TOTAL PERMIT FEES--------------> $2,087.25
Payments-------------------------------> $2,087.25
BALANCE DUE------------------------> 50.00
.....................................x,,...............,.........,....,.,«.,...�..�.....,.........._,............+,..._..................................._..........._,...,.,..,..,....
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM -4:00 PM.
combination permit_012811
�
• �
�t��F�'A� i ;.
..�................................................,.x.........�............,......,...,............,............,x...,...,.....,,,.....,,�,..........,.............,...,..,.,.....::,�
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: 613-0512 Address: 241 E MEADOW DR VAIL ,
� Owner: TOWN OF VAIL Location:
............�..............�.x�,.....,.....,....,..........,...,.........,,....,..................,.....,...............,�....x.,..........,........,..,.....,.....................t...
�,:,i
combination permit_012811
Y
�
�17N V��lLl1.r �
**�**«...*****,�«********�*****�.**.**.**..****************.**�*****************************.************.,*«««*******«*«*«*.*******�*****�*******«*.,*„
REQUIRED INSPECTIONS AND STATUSES
Permit#: 613-0512 Address: 241 E MEADOW DR VAIL
Owner: TOWN OF VAIL Location:
«„**.,.,*«***********.,*„*******************«**********�*****************************«******.*******�,***�**,.******.******««*******«***«***�««**„*«««**.,.
Item: 00120 ELEC-Rough
Item: 00190 ELEC-Final
Item: 00090 BLDG-Final
combination permit_012811
�
,�.. __ _R.r.,..._..... ,.._ �w�.r.��.,.�..�: ,�� � .,�_ M�... ...,�� .? _ _ ._n..�..,,._
_
� A
Department of Community Development
� 75 South Frontage Road
TOWN OF VA(L � �� vai�, CO 81657
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address: �i
� � Project#:
n � ` �c� ,
(Number) (Street) (Suite#) DRB#:_. _
� Building Permit#: 1�� � '�����
Building/Complex Name: �S �ti�,\.s�z'U�''�'�
Contractor Information Lot#: Block# Subdivision:
Business Name: ����� /'jl'�
Business Address: �12�p;�(v��� Work Class: New( ) Addition ( ) Alteration�, ,`
City � �� �,^ State:�Zip: — Type of Building:
� Single-Family( ) Duplex( ) Multi-Family( )
Contact Name: Commercial �Other( )
Contact Phone: ~ O
Contact E-Mail:_��f"j��j�iivrl�N� a `�Work Type: Interior O Exterior O Both O
I hereby acknowledge that I have read this application,filled out Valuation of
in full the information required,completed an accurate plot plan, Work Included Plans Included Work
and state that all the information as required is correct. I agree to � °- - - --
comply with the information and plot plan, to comply with all Town Elecfrical es ONo OYes ONo
ordinances and state laws, and to build this structure according to Mechanical ( )Yes ( )No ( )Yes ( )No
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other Plumbing ( )Yes ( )No ( )Yes ( )No
ordinances of the Town applicable ther,eto.
X � � ,
Building ( )Yes ( )No ( )Yes ( )No
���r.
� Value of all work being pertormed: $ ;
Owner/Owfier's Representative Signature(Required) ;;(value based on IBC Section 109.3&IRC Section 108.3� !
%� "Electrical Square Footage
�_, . . _ . . . . . . _. :
Applicant Information � `
. . .
Detailed Scope and Location of Work: / �l S�� � �
Applicant Name: y���W (`��� ��U,��_���r� ��'.K'.�—�•
Applicant Phone: �1�
Q vt �S r�� ���' ✓r f, i°:0 r�c�rn�r�
Applicant E-Mail: m � �_ -_. ,� c
��
Project Information
Owner Name:
Parcel#: ��� � U1�� ����r
�For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit
www.ea g lecou nty.uslpatie)
(use additional sheet if,_necessa )
For Office�Use Only: �� �� `��' ��.., I j M �
Date Received: �
Fee Paid: I �� DQ
Received From: NOV Q� 2��3
Cash Check# IJ ,2�YO Pm
CC: Visa/ MC Last 4 CC # exp date: �� .
Auth # TOWN OF VAfL. :
2013-Feb O1
COMcheck Software Version 3.9.2
Interior Lighting Complia�ce
Certificate
2012 IECC
Section 1: Project Information
Project Type:Alteration
Project Title:VAIL VILLAGE PARKING SKI MUSEUM
Construction Site: OwnedAgent: Designer/Contractor:
VAIL,CO STANTON HUMPHRIES
AEC
9707488520
STAN@J1EC-VAIL.COM
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
MUSEUM(Museum:General exhibition) 1350 1 1350
Total Allowed Watts= 1350
Section 3: Interior Lighting Fixture Schedule
A B C D E
Fixture ID:Description/Lamp 1 Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
� ,,g ��-�; '� �=: ��z
�✓ .�._..__�*i �,�,_ . .,� ���..�._�y,__,,. . .. _ �� �.__ .___�. fl -.._._ ., ,fa_,
� £�:�: �
LED 1:LED PAR 13W: 1 41 14 574
Track lighting 1:Wattage based on current limiting device ppaaty 0 0 0 775
Total Proposed Watts= 1349
Section 4: Requirements Checklist
Lighting Wattage:
� 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage:1350 Proposed Wattage:1349
Complies:YES
Mandatory Requirements:
� 2. Dwelling units(complete independent living faalities)within commercial buildings are not required to comply with interior lighting
requirements of this code provided tliat>=75 percent of the permanently installed fixtures other than low voltage lighting contain only
high efficacy lamps.
� 3. Manual Controls:Each endosed space has manual lighting control.Remotely located manual controls are labelled for area of service
and indicate on/off status.
Exception(s):
� Security/emergency areas with 24-hour operation.
� Stairvvays/corridors that are means of egress.
� 4. Light Reduction Controls:Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either controlling all luminaires,dual switching of altemate rows of luminaires,altemate luminaires,or alternate lamps,
switching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp.
Exception(s):
� Only one luminaire(lamp<100 V1�in space.
� An occupant-sensing device controls the area.
❑ The area is a corridor,equipmenUstore rooms,restrooms,public lobby,elec./mech.room, or sleeping unit.
0 Areas that use<0.6 Watts/sq.ft.
� Daylight spaces having automatic daylighting controls.
� 5. Automatic dme switching controls are installed and have an override switching device.The override switching device allows for<=2
hour operation cyGe within spaces<=5000 sq.ft.,manual operation,and is readily accessible and located where the operation of the
connected lights are visible or communicated to the switch.
Exception(s):
� Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security or where ligh6ng is
intended for 24-hour operation.
� Emergency egress lighting.
❑ Spaces where lighting is controlled with occupancy sensors.
� Malls,arcades,auditoriums,single tenant retaii spaces,industrial facilities and arenas that are<=20,000 sq.ft.are permitted
exceed the 2-hour opera6on cycle limit when a captive key device override switch is installed.
� 6. Occupant sensors are instalied in the foliowing spaces and automatically tum lighting off within 30 minutes of all occupants leaving the
space:Classrooms,conference/meeGng/training rooms,employee lunch and break rooms,private offices,storagefjanitorial rooms,
restrooms,and other spaces<=300 sq.ft.Automatic-on sensors set power on <50 percent power.
Exception(s):
� Full power automaticron controls are permitted where manual-on operation would endanger the safety or security of the room or
building occupants.
� 7. Daylight zones have either individual lighting controls independent from that of the generai area lighting that are either manual or
automatic and serve zones<=2,500 sq.ft.Zones under skylights more than 15 feet from the perimeter have lighting controls separate
from daylight zones adjacent to vertical fenestration.
Exception(s):
� Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.
� Daylight spaces endosed by walis or ceiling height parqtions and containing lwo or fewer light fixtures are not required to have a
separate switch for general area ligh6ng.
� 8. AutomaGc daylight zone controls are capable of reduang power to<35 percent using continuous dimming bailasts and
daylight-sensing controls OR,are capabie of automatic power reduction using step-dimming multi-level switching and daylight-sensing
controls having at least two control channels per zone and at least one control step in the 50-70 percent range and another<=35
percent of design power.
� 9. Mediql task lighting or artlhistory display lighting daimed to be exempt from compliance has a control device independent of the
control of the nonexempt lighting.
� 10.Separate control device for display/accent lighting,case lighting,task lighting,nonvisual ligh6ng,under-shelf/cabinent lighting,lighting
for sale,and demonstration lighting.
� 11. Hotel/motel sleeping units and guest suites have control device(s)at the entry door that control all permanent luminaires and switched
receptades.
� 12. Exit signs 5 Watts or less per sign.
� 13.Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts).
Exception(s):
� Electronic high-frequency ballasts.
� Luminaires not on same switch.
� Recessed luminaires 10 ft.apaR or surface/pendant not continuous.
❑ Luminaires on emergency cirouits.
. . . •
Section 5: Compliance Statement
Compliance Sfatement: The proposed lighting alteration project represented in this document is consistent with the building plans,
specifications and other calculaGons submitted with this permit application.The proposed lighting alteration project has been designed to meet
the 2012 IECC,Chapter 8,requirements in COMcheck Version 3.9.2 and mply with the mandatory requirements in the Requirements
check�ist. 11/8/13
Stanton Humphries, P.E.
Name-TiUe ignature Date
Project TiUe:VAIL VILLAGE PARKING SKI MUSEUM Report date: 11/08/13
I�ata filanama• llntitlari rr.k Paae 2 of 2
COMcheck Software Version 3.9.2
interior Lighting Compliance
Certificate
2012 IECC
Section 1: Project Information
Project Type:Alteration
Project Title:VAIL VILLAGE PARKING SKI MUSEUM
Construction Site: Owner/Agent: Designer/Contractor:
VAIL,CO STANTON HUMPHRIES
AEC
9707488520
STAN�EC-VAIL.COM
Section 2: Interior Lighting and Power Calculation
A B C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
MUSEUM(Museum:General exhibition) 1350 1 1350
Total Allowed Watts= 1350
Section 3: Interior Lighting Fixture Schedule
a B c � E
Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
�l�$�1 `��' � r , � = _ ��
. .:n
, h
�. ..��.�.a,� �� � � . �_ _.�.,�:;� __ FA�. ,
LED 1:LED PAR 13W: 1 41 14 574
Track lighting 1:Wattage based on current fimiting device capacity 0 0 0 775
Total Proposed Watts= 1349
Section 4: Requirements Checklist
Lighting Wattage:
� 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage:1350 Proposed Wattage:1349
Complies:YES
Mandatory Requirements:
� 2. Dwelling units(complete independent living facilities)within commeraal buildings are not required to comply with interior lighting
requirements of this code provided that>=75 percent of the permanently installed fixtures other than low voltage lighting contain only
high efficacy lamps.
� 3. Manual Controls:Each endosed space has manual lighting control.Remotely located manual controls are labelled for area of service
and indicate oNoff status.
F�cception(s):
p Securiry/emergency areas with 24-hour operation.
� Stairways/corridors that are means of egress.
� 4. Light Reduction Controls:Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either controlling all luminaires,dual switching of altemate rows of luminaires,altemate luminaires,or altemate lamps,
switching the middle lamp luminaires independenUy of other lamps,or switching each luminaire or each lamp.
Exception(s):
❑ Only one luminaire(lamp<10011�in space.
❑ An occupant-sensing device controls the area.
Project Title:VAIL VILLAGE PARKING SKI MUSEUM Report date: 11/OS/13
Ilof� filcn�mc• I Inhitln(i rrL Done 4 nf 9
p The area is a corcidor,equipmenUstore rooms,resVooms,public lobby,elec./mech.room, or sieeping unit.
p Areas that use<0.6 Watts/sq.ft.
� Daylight spaces having automatic daylighUng controls.
� 5. Automatic time switching controls are installed and have an override switching device.The override switching device allows for<=2
hour operation cyGe within spaces<=5000 sq.ft.,manual operation,and is readily accessible and located where the operation of the
connected lights are visible or communicated to the switch.
Exception(s):
� Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safety or security or where lighting is
intended for 24-hour operation.
� Emergency egress lighting.
❑ Spaces where ligh6ng is controlled with occupancy sensors.
� Mails,arcades,auditoriums,si�gle tenant retail spaces,industrial facilities and arenas that are<=20,000 sq.ft.are permitted
exceed the 2-hour operation cycle limit when a capGve key device ovemde switch is installed.
� 6. Occupant sensors are installed in the foliowing spaces and automatically tum lighting off within 30 minutes of ail occupants leaving the
space:Classrooms,conference/meeting/training rooms,employee lunch and break rooms,private offices,storage�anitor'�al rooms,
restrooms,and other spaces<=300 sq.ft.Automatic-on sensors set power on <50 percent power.
Exception(s):
p Fuli power automaticron conVois are permitted where manual-on operation would endanger the safety or security of the room or
' building occupants.
� 7. Daylight zones have either individual lighting controls independent from that of the general a�ea lighting that are either manual or
automatic and serve zones<=2,500 sq.ft.Zones under skylights more than 15 feet from the perimeter have lighting controls separate
from daylight zones adjacent to vertical fenestration.
Exception(s):
� Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.
� Daylight spaces endosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a
separate switch for general area tighGng.
� 8. AutomaGc daylight zone controls are capable of reducing power to<35 percent using continuous dimming ballasts and
daylight-sensing controls OR,are capable of automatic power reduction using step-dimming multi-level switching and daylight-sensing
controls having at least two control channels per zone and at least one control step in the 50-70 percent range and another<=35
percent of design power.
� 9. Medical task lighting or artlhistory display lighting daimed to be exempt from compliance has a control device independent of the
control of the nonexempt lighting.
� 10. Separate control device for display/accent lighting,case lighting,task lighting,nonvisual lighting,under-shelf/cabinent lighting,ligh6ng
for sale,and demonstration lighting.
� 11.Hotel/motel sleeping units and guest suites have control device(s)at the entry door that control all permanent luminaires and switched
receptades.
� 12. Exit signs 5 Watts or less per sign.
� 13.Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts).
Exception(s):
❑ Electronic high-frequency ballasts.
� Luminaires not on same switch.
� Recessed luminaires 10 ft.apart or surfacelpendant not continuous.
❑ Luminaires on emergency ciraiits.
. . . �
Section 5: Compliance Statement
Compliance Statement: The proposed lighting alteraGon project represented in Uiis document is consistent with the building plans,
specifications and other calculations submitted with this permit application.The proposed lighting alteration project has been designed to meet
the 2012 IECC,Chapter 8,requirements in COMcheck Version 3.92 and mply with the mandatory requirements in tl�e Requirements
chec�c�ist. 11/8113
Stan#on Humphries, P.E. -�
Name-TiUe ignature Date
Project Title:VAI�VILLAGE PARKING SKI MUSEUM Report date: 11/08(13
_ . ... .. .... . � Done 9 nf 9
���
C�Mcheck Software Version 3.9.2
� Interior Lighting Gompfiance
Certificate
2012 IECC
Section 1: Project information
Project Type:Alteration
Project Titie :VAIL VILLAGE PARKING SKI MUSEUM
Construction Site: Owner/Agent: Designer/Contractor:
VAIL,CO STANTON HUMPHRIES
AEC
9707488520
STAN a�EC-VAIL.COM
Section 2: Interior Lighting and Power Calculation
q g C D
Area Category Floor Area Allowed Allowed Watts
(ft2) Watts/ft2 (B x C)
MUSEUM(Museum:General exhibition) 1350 1 1350
Total Allowed Watts= 1350
Section 3: Interior Lighting Fixture Schedule
p B C D E
Fixture ID:Desc�iption!Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D)
Fixture Fixtures Watt.
MUSEUM(Museum:General exhibition'1350 sq.ft.)
LED 1:LED PAR 13W: 1 41 14 574
Track lighting 1:Wattage based on current limiting device capacity 0 0 0 775
Total Proposed Watts= 1349
Section 4: Requirements Checklist
Lighting Wattage:
� 1. Total proposed watts must be less than or equal to total allowed watts.
Allowed Wattage:1350 Proposed Wattage:1349
Complies:YES
Mandatory Requirements:
� 2. Dwelling units(complete independent living facilities)within commercial buildings are not required to comply with interior lighting
requirements of this code provided that>=75 percent of the permanently installed fixtures other than low voltage lighting contain only
high efficacy lamps.
� 3. Manual Controls:Each enclosed space has manual lighting control.Remotely located manual controls are labelled for area of service
and indicate on/off status.
Exception(s):
� Security(emergency areas with 24-hour operation.
� Stairwayslcorridors that are means of egress.
� 4. Light Reduction Controls:Each space required to have a manual control also allows for reducing the connected lighting load by at least
50 percent by either controlling all luminaires,dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps,
switching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp.
Exception(s):
� Only one luminaire(lamp<100 W)in space.
� An occupant-sensing device controls the area.
Project Title:VAIL VILLAGE PARKING SKI MUSEUM Report date: 11/08/13
Data filename: Untitled.cck Page 1 of 2
� The area is a corridor,equipmenUstore rooms,restrooms,public lobby,elec./mech.room, or sleeping unit.
� Areas that use<0.6 Watts/sq.ft.
� Daylight spaces having automatic daylighting controls.
� 5. Automatic time switching controls are installed and have an override switching device.The override switching device aliows for<=2
hour operation cycle within spaces<=5000 sq.ft.,manual operation,and is readily accessible and located where the operation of the
connected lights are visible or communicated to the switch.
Exception(s):
� Sleeping units,patient care areas;and spaces where automatic shutoff would endanger safery or security or where lighting is
intended for 24-hour operation.
� Emergency egress lighting.
� Spaces where lighting is controlled with occupancy sensors.
� Malls,arcades,auditoriums,single tenant retail spaces,industrial facilities and arenas that are<=20,000 sq.ft.are permitted
exceed the 2-hour operation cycle limit when a captive key device override switch is installed.
r� 6. Occupant sensors are installed in the following spaces and automatically turn lighting off within 30 minutes of all occupants leaving the
space:Classrooms,conference/meeting(training rooms,employee lunch and break rooms,private o�ces,storagefjanitorial rooms,
restrooms,and other spaces<=300 sq.ft.Automatic-on sensors set power on <50 percent power.
Exception(s):
� Full power automatic-on controls are permitted where manual-on operation would endanger the safety or security of the room or
building occupants.
� 7. Daytight zones have either individual lighting controls independent from that of the general area lighting that are either manual or
automatic and serve zones<=2,500 sq.ft.Zones under skylights more than 15 feet from the perimeter have lighting controls separate
from daylight zones adjacent to vertical fenestration.
Exception(s):
� Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device.
� Daylight spaces enclosed by walls or ceiling height partitions and containing two or fewer light fixtures are not required to have a
separate switch for general area lighting.
� 8. Automatic daylight zone controls are capable of reducing power to<35 percent using continuous dimming ballasts and
daylight-sensing controis OR,are capable of automatic power reduction using step-dimming multi-level switching and daylight-sensing
controls having at least two control channels per zone and at least one control step in the 50-70 percent range and another<=35
percent of design power.
� 9. Medical task lighting or artlhistory display lighting Gaimed to be exempt from compliance has a control device independent of the
control of the nonexempt lighting.
� 10. Separate control device for display/accent lighting,case lighting,task lighting,nonvisual lighting,under-shelflcabinent lighting,lighting
for sale,and demonstration lighting.
� 11. Hotel/motel sleeping units and guest suites have control device(s)at the entry door that control all permanent luminaires and switched
receptacles.
� 12. Exit signs 5 Watts or less per sign.
� 13.Tandem wired one-lamp and three-lamp bailasted luminaires(No single-lamp ballasts).
Exception(s):
� Electronic high-frequency ballasts.
� Luminaires not on same switch.
� Recessed luminaires 10 ft.apart or surface/pendant not continuous.
� Luminaires on emergency circuits.
. . .
Section 5: Compliance Statement
Compliance Statement: The proposed lighting alteration project represented in this document is consistent with the building plans,
specifications and other calculations submitted with this permit application.The proposed lighting alteration project has been designed to meet
the 2012 IECC,Chapter 8,requirements in COMcheck Version 3.9.2 and mply with the mandatory requirements in the Requirements
cneck�ist. ___._____.� 1118113
Stanton Humphries, P.E.
Name-TiUe � ignature Date
Project Title:VAIL VILLAGE PARKING SKI MUSEUM Report date: 11I08/13
Data filename: Untitled.cck Page 2 of 2