Loading...
HomeMy WebLinkAboutB13-0528 HEAT LOADS.PDF v�,;;,�;.;;;_ Load Short Form Job: 11152013JF Date: Nov 15,2013 `� Entire House 8,,: All American Heatin 9 400 North Park Ave�10-B,Breckenridge,Co 80424 Phone:970-453-6640 Fvc:970-453-2829 Email:Johnfulling@yahoo.com Web:www.AllAmericanHeatinglnc.com Li... • • ' ! • For: Ginsburg 3891 Bighorn Rd, Vail, Co 80111 � ° • o • Htg Clg infiltration Outside db (°F) -14 81 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 84 6 Fireplaces 1 (Average) Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 77 -61 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 120 ft Actual air flow 922 cfm High output baseboard 700 Btuh/ft Air flow factor 0.062 cfm/Btuh Total high baseboard 85 ft Static pressure 0 in H20 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Cig load Baseboard (ft) CIg AVF (ftz) (Btuh) (Btuh) Low High (cfm) Basement 308 3860 1178 8 6 73 Main Level 406 13111 2760 26 19 170 Living Area 322 13830 3142 28 20 194 Top Floor 740 29030 7873 58 41 486 Entire House 1776 59831 14952 120 85 922 Other equip loads 0 0 Equip. @ 0.86 RSM 12859 Latent cooling � TOTALS 1776 59831 12859 120 85 922 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �� -�d- wrightsoft� Right-SuiteO Universal 2012 12.1.08 RSU19569 2013-Nov-18 09:44:54 Page 1 ...ng\Desktop\Load Calcs 2013\Ginsburg 11 2013.rup Calc=MJ8 Front Door faces: N RECEI VED By David Rhoades at 10:51 am, Nov 19, 2013 B13-0528 �"°� Project Summary Job: 11152013JF Date: Nov 15,2013 Entire House By: All American Heating 400 North Park Ave#10-B, Breckenridge,Co 80424 Phone:970-453-6640 Fax:970-453-2829 Email:Johnfulling@yahoo.com Web:www.AllAmericanHeatinglnc.com Li... ' • � . For: Ginsburg 3891 Bighorn Rd, Vail, Co 80111 Notes: i - s • e Weather: Leadville, CO, US Winter Design Conditions Summer Design Conditions Outside db -14 °F Outside db 81 °F Inside db 70 °F �nside db 75 �F Design TD 84 °F Design TD g °F Daily range H Relative fiumidity 50 % Moisture difference -61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 51743 Btuh Structure 10433 Btuh Ducts 8088 Btuh Ducts 4519 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Pi in Equipment load 5983� Btuh Use manufacturer's data n Rate/swing multiplier 0.86 Infiltration Equipment sensible load 12859 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure -1736 Btuh Ducts -215 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2 1776 1776 Equipment latent load 0 Btuh Volume �ft3) 18116 18116 Air changes/hour 0.45 0.20 Equipment totai load 12859 Btuh Equiv.AVF (cfm) 135 60 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 120 ft Actual air flow 922 cfm High output baseboard 700 Btuh/ft Air flow factor 0.062 cfm/Btuh Tofal high baseboard 85 ft Static pressure 0 in H20 Space thermostat Load sensible heat ratio 1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^� WI'1 htsoft" 2013-Nov-18 09:44:54 �� 9 Right-SuiteOO Universal 2012 12.1.08 RSU19569 Page 1 ...ng\Desktop\Load Calcs 2013\Ginsburg 11 2013.rup Calc=MJ8 Front Door faces: N