Loading...
HomeMy WebLinkAboutA10-0064 plans LEGEND : S EQ U E N C E O I � J SYMBOL DEVICE MANUFACTURER/PART# MOUNTING 0 P E RAT 0 N S > � Q � FACP Caddx (NetworkX) NX-8E Battery Calculations � Q � � Fire Alarm Control Panel w/NX-2192 Addressable Card Mount on wall in manufacturer backbox Caddx NX-8E � �? ° `� ° o � KP Standby o � � � � J Q cn Q LCD Keypad/Annunciator Caddx (NetworkX) NX-148E Mount on wall in manufacturer backbox Number of Current Total Current � � � g cn m cn > cn Device T e Devices Am s Am s Q W O � � w O ESL 449CST (w/integral sounder o Yp � p ) � p ) o c� O c� c.� Main FACP CPU 1 X 0.075 = 0.075 � z = g z � z a- z Photoelectric Smoke Detector w/SI—ID Addressable Module 4" square box � NX 148E LCD Keypad 1 X 0.075 = 0.075 Q p � a � ~ � N � � � � O � O O U NX2192 Addressable Interface Card (max draw) 1 X 0.17 = 0.17 �` � � � � � � i-=- � System Sensor 5601 W SUM COLUMN FOR STANDBY LOAD 0.32 = AMPS W W = g z g z g z O Heat Detector � � � � � O � O � O w/SI—ID Addressable Module 4" square box DESCRIPTION > > � Q Q Q � z Alarm Load Q Q � z � z � z � 0 Number of Current Total Current � � � � O � O � O Device Type Devices (Amps) (Amps) Q Q � ~ ~ ~ ~ ~ ~ H❑ Sounder Gentex GX93W Single gang box � Main FACP CPU 1 X 0.14 = 0.14 NX 148E LCD Keypad 1 X 0.11 = 0.11 SMOKE DETECTOR �( �( �( NX2192 Addressable Interface Card (max draw) 1 X 0.17 = 0.17 KB Knox Box Sounder 1 X 0.015 = 0.015 SUM COLUMN FOR ALARM LOAD 0.435 = AMPS HEAT DETECTOR X X X Standby Load Required Standby Time in Hours Current (Amps) 0.32 X 24 = 7.68 AC POWER LOSS, GROUND FAULT, X X Alarm Load Required Alarm Time in Hours OPEN CIRCUIT Current (Amps) (15 MINUTES) � 0.435 X 0.25 = 0.11 Q Add Standby and Alarm Load for Required � Ampere Hour Battery 7.79 Multiply by the Derating Factor of 1.2 0 Total Ampere Hours Required = 9.35 Z Minimum Battery Size Provided: 10AH GENERAL NOTES: °(2A#sjP TDEVICET N SI—ID SI—ID o0 ADDRESSABLE ADDRESSABLE � 00 Note: The maximum draw for the NX 2192 Addressable InterFace Card was used. This accounts for all � � MODULE MODULE � initiating devices (smokes and heats) attaGhed to the system. Therefore, each device is not individually 1 . ALL EQ U I P M ENT I S TO B E I N STALLED AN D TESTED I N � accounted tor. ACCO R DAN C E W ITH MAN U FACTU R ER STAN DAR DS, FI R E ZONE WIRING ZONE WIRING � � D EPARTM ENT R EQ U I R EM ENTS AN D N FPA 72. POWER CKT 4—WIRE 2—WIRE ro NEXT � ° °' 2. R E F E R T O M A N U F A C T U R E R S D A T A S H E E T S A N D (2—#16) DETE�CTOR DETECTOR DEVICE � � � o INSTALLATION INSTRU CTIONS FOR FURTHER INFORMATION °' � Address Type of Device �eve� �escription REGARDING PRODUCT INSTALLATION WIRING DIAGRAMS, � � � 001 SMOKE DETECTOR LOWER CLOSETATFACP � 002 HEAT DETECTOR LOWER GARAGE NORTH PROGRAMMING AND DEVICE OPERATION. DATA/P OW E R LO O P D ETA � �� � 003 HEAT DETECTOR LOWER GARAGE SOUTH � � 004 HEAT DETECTOR UPPER LAUNDRY ROOM 005 HEAT DETECTOR UPPER KITCHEN 006 SMOKE DETECTOR UPPER LIVING ROOM � • 007 SMOKE DETECTOR UPPER GUEST BEDROOM 008 SMOKE DETECTOR UPPER HALL OUTSIDE BEDROOMS ^\ 009 SMOKE DETECTOR UPPER MASTER BEDROOM W 010 SPARE 1 Q— EOLR L� 011 SPARE (4 typ) (5 typ) �� 012 SPARE � 013 SPARE 0�4 SPARE 120VAC DEDICATED POWER CADDX BELL H EOLR 015 SPARE NX8E OUTPUT (1 typ� � 016 SPARE CONTROL PANEL � 0�7 SPARE TELEPHONE LINE - FIRE n, TELEPHONE LINE - SECURITY W 018 SPARE � � � w 019 SPARE � z 020 SPARE CADDX � o�o c~/� 021 SPARE DAOU P�M NX 148 U 022 SPARE KEYPAD � � o 023 SPARE � � o � 025 SPARE R S E R D AG RAM Cn ° � � X � 026 SPARE m � z 028 SPARE KEYPAD CIRCUITING, 4—#18AWG � � � 029 SPARE RISER NOTES: 4 WIRE DATA/POWER, 4–#16AWG (2 PAIR) 030 SPARE 1 . REFER TO CADDX NX-8E INSTALLATION MANUAL FOR MORE 031 SPARE INFORMATION. — - - 2 WIRE SOUNDER CIRCUIT, 2—#18AWG 032 SPARE 2. WIRE SIZE MAY BE VARIED, PROVIDED IT MEETS MANUFACTURERS 033 SPARE SPECIFICATIONS. 034 SPARE 035 SPARE 036 SPARE 037 SPARE O 039 sPARE P R 0 J E C T I �l �0 R M AT I 0 �l o � 040 SPARE � MUE � � ER RES DENCE ' ti NOTE: LEVEL WILL BE INCLUDED IN DEVICE ADDRESS DESCRIPTION. N VA � , C0 �0RAD0 o w ti � � R E A AR M SYSTE M �' � � w AHJ: VAIL FIRE DEPARTMENT U Q APPLICABLE CODES: 2007 NFPA 72, 2009 IFC, 2009 IBC � _ OCCUPANCY: GROUP R � � USE: SINGLE FAMILY HOME �— J FIRE ALARM SYSTEM FOR SINGLE FAMILY RESIDENCE. SYSTEM INCLUDES W = SMOKE DETECTORS IN SLEEPING ROOMS, AREAS OUTSIDE OF SLEEPING J � ROOMS AND STAIRWELL LANDINGS. HEAT DETECTORS ARE PROVIDED IN w W � THE KITCHEN, GARAGE AND LAUNDRY ROOM. THE SMOKE DETECTORS V J m HAVE INTEGRAL SOUNDERS. A HORN IS ALSO PROVIDED IN THE GARAGE. w � j W A KEYPAD IS PROVIDED AT THE ENTRY FOR SYSTEM CONTROL. � 0 � � � � � � w O m � � U � J Q � Z �� r r�����; ., � �„"• " „�.�,��, J � H `��,��'°-�1��'A�.,�'`�t` ��,�r� ;=�s r'f� �--�--� 0 z Cn FIRE PROTECTION ENGINEER: �p� ����a� �' .� � � O � �K a ��� i �:s ;' 'q.' S HAN E R LI FE SAFETY 'F � ��;:r�� PO BOX 1073 �' :�, „ . '�[y�� DRAWN BY: DATE: ..t1,'•. �s�`�c�r��i�� FRISCO, CO 80443 DLS $/20I10 PHONE: 970-409-9082 FAX: 9 70—79 7- 189 8 SHEET DESCRIPTION: COVER SHEET LEGEND SHEET#: FA-00 Z O � d � U � w � Z O � > w � — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � � � � � � � i i � - - - - - - - - - - - - - - - � CLOSET � I O O /� H2O W � I CLOSET I ----- ------------- / W � �- , LAUNDRY � � MECHANICAL O O // I z �- — I I � YLIGHT � I � a o I I DINING I � J 004 / I BOILER / � , I I �-----1-----, I I � I I � KITCHEN I z I I � SKYL�IGHT � // I EOLR �-----I-----� 1 � RO M B EL W I o�o � BEDROOM 2 I I 005 /� I � � I � 9 I I � o0 r----- --------- ---� � � � I I I I � YLIGH ' � � � � � / � � � � � �------ ------ ------' � � � � O � � � � // I / � � � � � // I W O x I I L I V I N G � �� I TO ABOVE 1 n- � � � ROOM � 006 // I 003 `�— � � �-----�-----, 2 / UPPER 1 1 � � I ; I I � ENTRY I II � SKYI�IGHT i / - - - - - - - - - - - - - - - - - - - - - - - - - J OOZ � � � � I � � I MASTE R I �-----I-----� \ I \ W I � � I I � � I GARAGE GARAGE � I O � �� 0 I � � 0 0 Q � 0 0 8 � � I � • I I I � I 4 I I � � CLOSET \\ — � � I I I � i I I �-- -t-----; OFFICE \� � I H W � � I I � SKYI�IGHT ! \� I I U O � � � � i I i I � � z I I �_____+_____, I ' � � I ? SITTING I � Q � 007 � � I 1 ° � � BEDROOM I I � � � � p � � I CLOSET I ENTRY � � .- U � � � - - - - - - - - - - - - - - - - - � � � — � � � � � � I m O Q � � � � � � � I � I IKB I � - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - L - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � L — - - - - - � - - - - - - - J RECESS DOORWAY � N � � ti ONO ' � W O � ti � � C� W EH LEVEL PLAN GARAGE LEVEL PLAN � z U z � o = � � NORTH NORTH � J U = � Q w w � v J O z z� Q w 0 0 > ° � � � � � w O m � � U � J Q � Z �� r r�����; ., � �„"• " „�.�,��, J � H `��,��'°-�1��'A�.,�'`�t` ��,�r� ;=�s r'f� �--�--� 0 z Cn C�:� ����a� �;� �.a � � � L1.� � °� � � U � �:� i ' ;' •..��j: R' ry f � ' I ,•"�y� DRAWN BY: DATE: �s�,������.�, DLS 8/20I10 SHEET DESCRIPTION: FLOOR PLANS LAYOUT SHEET#: FA-01