Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DRB130496 Revised Plans
wireless STRUCTURES CONSULTING, PC ALL BOLTS TO BE TIGHTENED TO A "SNUG-TIGHT" CONDITION AS DEFINED IN AISC 13TH EDITION, PAGE 16.2-46 PARAGRAPH 8.1 THE SNUG TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. GENERAL DESIGN NOTES DESIGN NOTES AND MATERIAL REQUIREMENTS: 1) THE DESIGN CRITERIA FOR THIS STRUCTURE IS AS FOLLOW: A) STANDARDS AND DESIGN CODES: INDUSTRY STANDARDS: ANSI / TIA 222-G & 2009 IBC STEEL MANUAL: AISC 13TH EDITION CONCRETE CODE: ACI 318-08 WELDING CODE: ANSI / AWS D1.1-06 B) DESIGN: WIND: 90 MPH (3-SECOND GUST) PER ANSI/TIA 222-G & 2009 IBC, (SECTION1609.1.1, EXCEPTION 5) CLASSIFICATION OF STRUCTURE: II EXPOSURE CATEGORY: C TOPOGRAPHIC CATEGORY: 1 ICE: NOT REQUIRED FOR THIS STRUCTURE PER ANSI/TIA-222-G(2), ANNEX B SEISMIC: PER 2009 IBC SECTION 1613, ASCE 7-05 SECTIONS 15.1.3 & 12.8 SOIL: PER 2009 IBC, TABLE 1806.2, CLASS 5 MATERIAL C) DESIGN LOADING: (1) - 24 OD X 6' TALL ANTENNA SHRD, BASE @ 29'-0" AGL (2) - RUKUS ANTENNAS FLUSH MNT C.L. @ 27'-6" AGL (1) - 30" TALL X 18" WIDE LUMINAIRE(FLAT), C.L. @ 16.3' AGL (1) - 3" TALL X 3' LONG LUMINAIRE SUPPORT ARM, C.L. @ 15' AGL (5) - ANDREW ION RADIOS (M85P/19HP OR M7P7P EU), INT. MNTD. D) FACTORED BASE REACTIONS OVERTURNING MOMENT = 18.7 foot-kips BASE SHEAR = 0.93 kips VERTICAL = 1.99 kipS2) GENERAL STRUCTURAL NOTES: A) ALL MATERIALS SHALL CONFORM TO THE FOLLOWING STANDARDS: PIPE: ASTM A53/A500 GR. B PLATES: ASTM A36 PORTS: ASTM A500 GR.B WELDS: E70XX ELECTRODES ANCHOR BOLTS: ASTM F1554 GR.55 BOLTS: ASTM A325 REBAR: ASTM A615 GR.60 B) COATINGS: GALVANIZING: ASTM A123 POWDER COAT FINISH: (RAL COLOR BLACK) C) ALL WELDING TO BE PERFORMED BY WELDERS CERTIFIED IN ACCORDANCE WITH AWS D1.1. FIELD WELDING IS PROHIBITED. D) ALL STRUCTURAL BOLT SHALL BE TIGHTENED TO SNUG-TIGHTAS DEFINED BY AISC 13TH ED., PG. 16.2-46 PARAGRAPH 8.1 TIGHTENING NOTES 8" NODE: 10 A HAD THD'D RODS w/ LW 07NOV13 MANUFACTURER 35'-0" ANTENNA CONCEALMENT POLE, 6'-0" SHROUD VAIL NODE NETWORK TITLE REV - DATEDRAWN BY S1 SG SHEET 06NOV1313-0377 AM CHECKED BY 1 ALL DIMENSIONS INCLUDE SALEM, OR 97303FINISHES AND ARE IN INCHES BYDATEUNLESS OTHERWISE SPECIFIED WSC PROJECT NUMBER WWW.WSCENGINEERING.COM ANGLES 13377-INST(C) Ph: 503-587-0101 Fx: 503-316-1864 DESCRIPTIONREV. REVISIONS P.O. BOX 7293 STRUCTURES CONSULTING, P.C. IS PROHIBITED DRAWING NUMBER TOLERENCE: FRACTIONS 1/16"THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WIRELESS STRUCTURES CONSULTING, P.C. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF WIRELESS SG 1394#TOTAL GALV. WEIGHT PER STRUCTURE = PART #DESCRIPTIONQTY.UNIT WT.(#)377-2710 3/4" OD POLE WELDMENT, 28'-7 1/4" LONG11087.7377-52 3/8" O.D. x 6'-0" ANTENNA MAST WELDMENT127.894-324" OD SHROUD SUPPORT144.794-S3-124" O.D. TOP CAP WELDMENT151.4--- 24" O.D. X 6'-0" TALL ENCLOSMENT SHROUD HALF234.07WA-400ANTENNA BRACKET FOR 2 3/8" O.D. PIPE121.3PL-53911 GA A569 FORMED ANTENNA BRACKET120.52WA-463PLATE WELDMENT 13.8WA-5051'-2" x 2'-8" A36, PLATE WELDMENT116.213007-181/4" x 3 1/2" x 6 1/2" A36 FLATBAR11.5PL-7116" x 12" PORT COVER12.5PL-71611 GA X 5 1/4" X 9" X A569 COVER PLATE11.6PL-718BUS BAR 20.8PL-81411 GA x 8 3/8" x 3'-4 3/4" VENTED RADIO PORT COVER59.7260801/4" x 3" G5 FLANGED BOLT, ZINC2-400021/4" FLAT WASHER, ZINC20-410021/4" LOCK WASHER, ZINC20-555001/4"-20 SPEED NUT, ZINC2-555951/4" NUT, ZINC 20-802561/4" x 1 1/2" THRD STUD, ZINC20-152503/8" x 1 1/2" A307 BOLT, NUT, & L.W., GALV.12-152603/8" x 1 3/4" A307 BOLT, NUT, & L.W., GALV.24-262203/8" x 1" G5 FLANGED BOLT, ZINC12-400113/8" FLATWASHER, GALV.24-430103/8" LOCKWASHER, S.S.8-710173/8" x 5/8" BOLT, S.S.8-900603/8" STANDOFF INSULATOR (559640)4-911153/8" x 1" FLAT HD SOCKET CAP SCREW, ZINC4- 911273/8" x 3/4" NYLON SCREW18- 164701/2" x 1 1/2" A307 BOLT, GALV.2- 510101/2" A563 HEX NUT, GALV.4- 650301/2" x 2 1/2" x 4" A36 U-BOLT ASSY., GALV.1- 102905/8" x 3" A325 BOLT, NUT, & L.W., GALV.3- 912203/4" x 8 1/2" EXPANSION ANCHOR ASSEMBLY, ZINC4- & LEVELED AS REQ'D (2 PLCS) (BY OTHERS) ION-M RADIO 1'-2 1/2" (BOTH HIDDEN FOR CLARITY)24" O.D. x 6'-0" TALL w/ DISCONNECT (4 PLCS TOTAL) AGL (2 PLCS) TO ACHEIVE PLUMNESS 35'-0" 0'-0" B.O. STRUCTURE (BY OTHERS) METER LOAD CENTER C.L. ACCESS PORT (6"x12") (E) CONCRETE BASE, SHIM AROUND BASE & POLE (BY OTHERS) IN POLE AGL 29'-0" AGL BASE OF ANTENNA MAST MC0816B1150JLT AGL7'-5 1/2" ELEVATION VIEW C.L. ACCESS PORT (6 1/2"x38") PL-711 AGL C.L. ACCESS PORT (6 1/2"x38") 11'-1 1/2" 14'-9 1/2" AGL C.L. ACCESS PORT (6 1/2"x38") 18'-5 1/2" C.L. ACCESS PORT (6 1/2"x38") AGL AGL C.L. ACCESS PORT (4"x6") C.L. FUTURE ANTENNAS 30'-9" 33'-9" AGL 94-S3-1 22'-7" AGL 3'-9 1/2" AGL C.L. KATHREIN SCALA 840 10510 (x3)94-3377-5 TOP OF STRUCTURE PL-716 PL-814 840 10510ENCLOSURE SHROUD HALF (5 PLCS) 377-27 (BY OTHERS) AGL WA-505 AGL5'-0" BREAKER BOX C.L. ACCESS PORT (6 1/2"x38") KATHREIN SCALA T.O. DISCONNECT BOX WA-463 (2) DRILL 13/16" HOLE IN (E) CONCRETE BASE FOR 3/4" x 8 1/2" EXPANSION ANCHOR BOLTS w/ 6 1/4" EMBED TO MATCH HOLES IN PLATES A A C C (2 PLCS)SECTION C-C 1647094-3-1 PL-711 377-27 (4 PLCS) 51010 PL-718(2 PLCS) SECTION A-A (2) 71017, (2) 43010, & (1) 90060 wireless STRUCTURES CONSULTING, PC (2 PLCS) 55500 (2 PLCS) DETAIL A PL-711 26080 377-27 (4 PLCS) 40002, 41002, & 55595 PL-814 Ion-M Radio DETAIL B (2 PLCS) 26220 80256(4 PLCS) 377-27(3 PLCS)1029094-3 DETAIL C377-27 377-5 PL-718(2 PLCS) SECTION F-F 65030 13007-18 & (1) 90060 (2) 71017, (2) 43010, 94-3 377-5 DETAIL E 377-27 91220 (4 PLCS) HAD THD'D RODS w/ LW 07NOV13 MANUFACTURER 35'-0" ANTENNA CONCEALMENT POLE, 6'-0" SHROUD VAIL NODE NETWORK TITLE REV - DATE CHECKED BY WSC PROJECT NUMBER A SHEET NODE: 10 DRAWN BY 13-0377 SG S2 13377-INST(C) Ph: 503-587-0101 Fx: 503-316-1864 SALEM, OR 97303FINISHES AND ARE IN INCHES BYDATEDESCRIPTIONREV. 1 WWW.WSCENGINEERING.COM ANGLES UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS INCLUDE REVISIONS P.O. BOX 7293 STRUCTURES CONSULTING, P.C. IS PROHIBITED DRAWING NUMBER AM 06NOV13TOLERENCE: FRACTIONS 1/16"THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WIRELESS STRUCTURES CONSULTING, P.C. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF WIRELESS SG (4) DETAIL DDETAIL C (5) DETAIL B DETAIL A DETAIL E (4 PLCS) PL-814 94-S3-1377-5 WA-463 ISOMETRIC VIEW (ONLY 1 SHOWN FOR CLARITY) WA-505 PL-711 24" O.D. x 6'-0" TALL94-3ENCLOSURE SHROUD HALF(9 PLCS)(BOTH SIDES) PL-716 (2 PLCS) 26220 (5 PLCS) 377-27 91127 91115 F F (3 PLCS)15260 WA-400(6 PLCS)(3 PLCS)15250 w/ (2) 40011 DETAIL D (3 PLCS)PL-539377-5 ISSUE DATE: SHEET NUMBER: SHEET TITLE: SEAL: SITE INFORMATION: BY:DESCRIPTION:DATE:NO. PLANS PREPARED BY: CLEAR CREEK CANYON DAS INSTALLATION CLEAR CREEK CANYON ROAD -- CO. HWY 6 AND HWY 119 -- STATE OF COLORADO APR.12.2012 2000 CORPORATE DRIVE CANONSBURG, PA 15317 COPYRIGHT©2012 Studio Z Architecture aZ@ZYmR.co E-0 ELECTRICAL ONE LINE, AND NOTES GENERAL PROJECT NOTES 1.THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A COMPLETE AND FUNCTIONING ELECTRICAL SYSTEM. 2.MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES, LAWS AND ORDINANCES OF FEDERAL, STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. 3.ALL MATERIAL, EQUIPMENT, WIRING DEVICES, ETC. SHALL BE NEW, UNLESS SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. 4.PROVIDE COMPLETE METALLIC RACEWAY SYSTEMS AND ENCLOSURES FOR ALL WIRING THROUGHOUT THE EXTENT OF THE REQUIRED SYSTEM. 5.FLEXIBLE CONDUIT CONNECTIONS TO RECESSED LIGHTING FIXTURES SHALL BE MADE WITH FLEXIBLE STEEL CONDUIT, 3/8 INCH MINIMUM. 6.FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH LIQUID TIGHT FLEXIBLE STEEL CONDUIT, 1/2 INCH MINIMUM. 7.ALL CONDUCTORS INSTALLED IN INTERIOR DRY LOCATIONS SHALL BE TYPE THWN OR THHN THERMOPLASTIC 600V INSULATED COPPER CONDUCTORS.NO WIRE SMALLER THAN NO. 12 SHALL BE USED FOR LIGHTING OR POWER WIRING. WIRE NO. 8 AND LARGER SHALL BE STRANDED. ALL CONDUCTORS INSTALLED IN EXTERIOR OR WET LOCATIONS SHALL BE TYPE THWN 600V INSULATED COPPER CONDUCTORS. 8.ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTING PANELBOARDS SHALL MATCH EXISTING BUILDING PANELBOARD MANUFACTURER AND BREAKER TYPE.THE CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES FOR ALL NEW PANELS CHANGED. 9.EACH SWITCH, LIGHT, RECEPTACLE AND OTHER MISCELLANEOUS DEVICE SHALL BE PROVIDED WITH A GALVANIZED OR SHERARDIZED PRESSED STEEL OUTLET BOX OF THE KNOCKOUT TYPE, OF NOT LESS THAN NO. 14 U.S. GAUGE STEEL.CONDUITS SHALL BE FASTENED WITH LOCKNUTS AND BUSHINGS AND ALL UNUSED KNOCKOUTS MUST BE LEFT SEALED.THERE MUST BE SUFFICIENT ROOM FOR WIRES AND BUSHINGS AND DEEP BOXES SHALL BE INSTALLED WHERE REQUIRED.BOXES SHALL BE SECURELY AND ADEQUATELY SUPPORTED. 10.PROVIDE LOCAL DISCONNECT SWITCHES FOR ALL MOTORS (PLENUM APPROVED AND AS REQUIRED). 11.NUMBERED CIRCUITS ARE FOR CONVENIENCE OF DESIGN ONLY.ACTUAL FIELD CONDITIONS WILL VARY.INDICATE THE CIRCUIT NUMBER USED ON THE "AS-BUILT" DRAWINGS. ELECTRICAL LEGEND NOTE: NOT ALL ITEMS APPEAR ON DRAWINGS. SYMBOLS MAY DIFFER FROM EXISTING AND DEMO WORK OR DEVICES REFERENCED FROM DRAWINGS BY OTHERS. T ABBREVIATIONS E.C. WP GFI TRANSFORMER GROUND FAULT INTERRUPTING ELECTRICAL CONTRACTOR WEATHER PROOF ELECTRICAL PANEL BOARD EQUIPMENT DISCONNECT SWITCH EQUIPMENT FUSED DISCONNECT SWITCH REFERENCE SYMBOLS FEEDER - SEE SCHEDULE XFMR kVA TRANSFORMER WITH GROUNDING AND OVERCURRENT DEVICES SEE TRANSFORMER SCHEDULE #/W XX AHJ AUTHORITY HAVING JURISDICTION 60S/3 100G NG GRADE LEVEL SERVICE RATED NEMA 3R PANELBOARD WITH MAIN BREAKER AND MINIMUM 4-CIRCUIT MOUNTED ON POLE 60S/3 3#4, 1"C 100G #4 Cu Feeder Schedule Conductors shall be sized and installed in accordance with NEC. T CUSTOMER OWNED PAD MOUNTED 15kVA TRANSFORMER 240/120V, 1-PHASE, 3W SECONDARY, VERIFY PRIMARY VOLTAGE WITH OWNER BOND AND GROUND PER NEC 250xGROUND RODSxGROUND RINGxSTEEL REFERENCE SHEETS G-1 AND G-2 20A 20A CABINET #1 CABINET #2 60/2 FAULT CURRENT CALCULATION TABLE NOTES: 1. 2. 3. 4. 5. LOCATION (n) 15 Utility Meter (LOAD CENTER) All Calculations utilize Bussman "Point-To-Point" Method. Variables: The E.C. shall field report any discrepancies to the Engineer. Conductor lengths shall not be less than the values listed. The E.C. shall field verify conductor lengths and contact engineer immediately if conductor lengths are less than the values shown. Conductor Lengths listed in this table are for fault study purposes only and shall not be used for bidding or other calculations. # of RUNS Transformer 1 L=Feeder Length (LF) C=Conductor "C" Value CONDUCTOR 4 V(L-L) 240 240 M(n) =1 ÷ (1+f(n)) F(n)=F(n-1) x M(n) V(L-N) 120 120 1=Steel 2=Non-Mag 2 L(ft) 15 f(n)(L-L) = (2 x L x F(L-L)(n-1))/(C x # of runs x VOLTAGE) in Amperes f(n)(L-N) = (2 x L x F(L-N)(n-1))/(C x # of runs x VOLTAGE) in Amperes C 3,826 f(L-L) 0.10 f(L-N) 0.43 M(L-L) 0.91 April 13, 2012 M(L-N) MINIMUM Z = 2% 0.70 F(L-L) 3,125 2,836 F(L-N) 6,510 4,567 20A CDOT CABINET PANEL 'A' EXISTING CUSTOMER-OWNED PRIMARY DESIGNED BY OTHERS (PRIMARY METERING BY XCEL) ISSUE DATE: SHEET NUMBER: SHEET TITLE: SEAL: SITE INFORMATION: BY:DESCRIPTION:DATE:NO. PLANS PREPARED BY: CLEAR CREEK CANYON DAS INSTALLATION CLEAR CREEK CANYON ROAD -- CO. HWY 6 AND HWY 119 -- STATE OF COLORADO APR.12.2012 2000 CORPORATE DRIVE CANONSBURG, PA 15317 COPYRIGHT©2012 Studio Z Architecture aZ@ZYmR.co E-1 ELECTRICAL PLAN & PANEL SCHEDULE ELECTRIC SERVICE TRANSFORMER (DESIGNED BY OTHERS) INSTALL A SAFE DISTANCE AWAY FROM ROADWAY AND MAINTAIN REQUIRED CLEARANCES REQUIRED BY UTILITY, CDOT, AND NEC ELECTRICAL SERVICE DISCONNECT AND LOAD CENTER BELOW, TYPICAL RADIO EQUIPMENT CABINETS ABOVE ON POLE, TYPICAL. PROVIDE BRANCH CIRCUIT CONNECTIONS TO EACH CABINET PANEL SCHEDULE: BUS RATING: MAIN C.B.: MOUNTING: COMMENTS: CIR NO. 1 3 NOTES: 1. CIRCUIT AMPS 20 20 Not Used. 60A 60A Surface New Panelboard, NEMA 3R, Service Rated BREAKER POLE 1 1 PHASE A (VA): PHASE B (VA): TOTAL LOAD (VA): 1Ø, 3-WIRE or M.L.O: CONNECTED LOAD (VA) 180 680 500 1,180 A NEC DEMAND FACTOR 1.00 DESCRIPTION OF LOAD SERVED CDOT Cabinet Spare PHASE A B VOLTAGE L-L: VOLTAGE L-G: S.C.RMS RATING (AIC): DESCRIPTION OF LOAD SERVED Cabinet #1 Cabinet #2 PHASE A (VA): PHASE B (VA): TOTAL DEMAND LOAD (VA): 240 120 22,000 NEC DEMAND FACTOR 1.00 1.00 680 500 1,180 March 14, 2012 CONNECTED LOAD (VA) 500 500 4.92 CIRCUIT POLE 1 1 A BREAKER AMPS 20 20 CIR NO. 2 4 CDOT CABINET, PROVIDE 1-GANG OUTLET BOX WITH DUPLEX 15A GFCI RECEPTACLE PER CDOT STANDARDS