Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A13-0073 plans approved.pdf
a m ® m 0 y d o N d w Lo Cc 1\ 00 0 M M m M M LODGE TOWER 0� m Z H C3 Q �, U)E � e� o FIRE ALARM SYSTEM m a Lo fa�i o `V 07 0�L a o VDU n Q� CDZ> ° N NWW o O cfl O Cn a, E 0 U ^O d 3 No LIc ° o�• p Av• � a • Fo 44967 xi • s 3 �'•� 9/23/13 •.•'�Q Fss/ NN- O SITE ENGINEER OF RECORD DRAWING INDEX m Sheet Number Sheet Title a FA-001 COVER SHEET LODGE TOWER SIMPLEXGRINNELL FA-002 GENERAL INFORMATION n 200 VAIL ROAD MARCEL D . PROULX FA-101 BASEMENT DEVICE PLACEMENT PLAN FA-102 GROUND FLOOR DEVICE PLACEMENT PLAN VAIL COLORADO 81657 6240 SMITH ROAD FA-103 FIRST FLOOR DEVICE PLACEMENT PLAN ■ a I N FA-104 SECOND FLOOR DEVICE PLACEMENT PLAN DENVER, COLORADO 80216 FA-105 THIRD FLOOR DEVICE PLACEMENT PLAN FA-106 FOURTH FLOOR DEVICE PLACEMENT PLAN M 303-355-0500 N FA-107 FIFTH FLOOR DEVICE PLACEMENT PLAN 0 FA-108 SIXTH FLOOR DEVICE PLACEMENT PLAN 0 INSTALLER FA-109 SEVENTH FLOOR DEVICE PLACEMENT PLAN m FA-201 BASEMENT - 3RD FLR RISER DIAGRAM y L FA-202 4TH FLR - ATTIC RISER DIAGRAM � A K ELECTRIC w FA-501 FACP PANEL DETAIL P . O . BOX 6241 FA-502 TRANSPONDER PANEL DETAIL O o FA-601 UPGRADED 4100ES FACP CALCULATIONS AND SCHEDULES FA-602 NEW 4100ES TRANSPONDER CALCULATIONS AND SCHEDULES L U � o 0 AVON COLORADO 81620 Ow J FA-701 WIRING TYPICALS O ~ J O PHONE : 970-376-8165 FA-702 WIRING TYPICALS o O O o° Q J � N > a E� E .m L_ N N T f0 � C � o c 5 m 3 ° c c ?n w U) y @ v J c ° o � CD Mn C N O Z a o m N m D a E W m o Q rn o c — (n Z m c ° E C U o W E > 0 o m `c E Y c o Nn U d � a, E m t Q � o C7 x co m 6240 SMITH ROAD o co DENVER, CO 80216 co w CD N N ^o c O S LU m m PHONE: 303-355-0500 DRAWN BY: SERVICE: 303-355-0500 CHECKED BY: SSW n ell FAX: 303-355-0615 ISSUE DATE: 9/19/13 JOB#: PROJECT#: 419:972539701 o t SIMPLEXGRINNELL© 2013 >° rM FIRE DEPT./BLDG DEPT. PLAN REVIEW #. N ■ SYSTEM: w Safer. Smarter. CO, FIRE ALARM SYSTEM Y SHEET: y VA L ERE & EMERGENCY SERVICES L3 ; PROJECT MANAGER 42 WEST MEADOW DRIVE COVER SHEET 3 Ol N C ERIC NAVARRO VAIL, COLORADO 81 657 m m N 303-358-5017 (970> 479-2250 0 ENAVARRO SIMPLEXGRINNELL. COM z C.0 FA-001 z x d T d N w M N — w GENERAL NOTES SYSTEM DESCRIPTION SCOPE OF WORK SYMBOL KEY c ° 1. THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES °O SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. FIRE ALARM SYMBOLS LEGEND M M 2. SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJOR OCCUPANCY TYPE: R-2 RESIDENTIAL GROUP MM DEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT SIMPLEXGRINNELL IN A TIMELY MANNER SO AS NOT TO IMPAIR THE CONSTRUCTION SCHEDULE. SPRINKLER PROTECTION: BUILDING IS FULLY SPRINKLED SYMBOL DESCRIPTION M O D E L# BAC K B O X o .. 3. CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING _'� AS REQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY UPGRADED SUPPLIED BY SIMPLEXGRINNELL a_" AUTHORIZED CHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. MODIFY EXISTING FIRE ALARM SYSTEM: PROVIDE NEW SPEAKER/STROBES, RELOCATE SMOKE 4100ES FIRE ALARM CONTROL PANEL SIMPLEX 4100-9111 (REFER TO MOUNTING DETAIL FOR SPECIFIC DIMENSIONS) C3 4. A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR DETECTORS AS SHOWN ON DRAWINGS. UPGRADE EXISTING 41000 FIRE ALARM PANEL TO NEW 4100ES FACP W / MULTIPLE BATTERY SETS REFER TO BATTERY CHARTS ��' co INSTALLATION. FIRE ALARM PANEL. ADD NEW 4100ES VOICE TRANSPONDER IN GARAGE. DEMO EXISTING 2120 5. THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A TRANSPONDERS AND EXTEND WIRES TO NEW 4100ES TRANSPONDER. NEW SUPPLIED BY SIMPLEXGRINNELL �� i C BRANCH CIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS FIRE TPR FIRE ALARM TRANSPONDER PANEL SIMPLEX 4100-9600 (REFER TO MOUNTING DETAIL FOR SPECIFIC DIMENSIONS) % � °N°_tj ALL NEW WIRING TO BE CLASS B. FACP W EXTERNAL BATTERY SET REFER TO BATTERY CHARTS _� <0 ALARM CIRCUIT CONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE / PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. =° o s THE EXISTING FIRE ALARM SYSTEM SHALL NOT BE DISCONNECTED OR TAKEN OUT OF SERVICE EXISTING NAC EXTENDER PANEL 6. UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO cv M032 SIMPLEXGRINNELL NO LATER THAN 7 DAYS AFTER FINAL TEST. WITHOUT WRITTEN PERMISSION FROM THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO # DESIGNATES THE NAC PANEL NUMBER SIMPLEX 4009-9201 SUPPLIED BY SIMPLEXGRINNELL co> £ 7. THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMAN LIKE MANNER. COORDINATE WITH THE OWNER THE TIMING OF ANY EXISTING FIRE ALARM SYSTEM DEMOLITION WORK. 1 W / 1 OAH BATTERY SET SIMPLEX 2081-9274 y CN NAC o to 8. DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED SIMPLEXGRINNELL TECHNICAL REPRESENTATIVE. to ° °U) 9. ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO LLHC j FIRE ALARM TERMINAL CABINET SUPPLIED BY OTHERS SUPPLIED BY OTHERS PROTECT FROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARM INSTALLER. 10. THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF EXISTING �p,P40•L/C�c� ASSEMBLIES ANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED. MANUAL PULL STATION SIMPLEX 4099-9001 SINGLE GANG BOX 2 1/2" DEEP O::•• ro•.•:s 11. INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED AND •�� 9 a NON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITH EXISTING SIMPLEX 4098-9714 ;¢ 44967 MANUFACTURERS INSTRUCTIONS AND NEC. 12. ALL WIRING SHALL BE INSTALLED ACCORDING TO NFPA 70 (NEC). O SMOKE SENSOR / BASE SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP o�� � w 13. FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPROPRIATE SECTION OF NEC 760. MARK ALL FIRE S S = SOUNDER BASE SIMPLEX 4098-9794 BASE 4 OCTAGONAL BOX 1 1/2 DEEP �'p'.• 9/23/13 ALARM WIRES IN ACCORDANCE WITH NEC 760 SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE. EXISTING SIMPLEX 4098-9733 ��ss/••••••����\� ° FPLP. FIRE ALARM APPLICABLE CODES & STANDARDS o 14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE 1 HEAT SENSOR / BASE SIMPLEX 4098-9792 BASE 4" OCTAGONAL BOX 1 1/2" DEEP 0 15. FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATE MORE THAN ONE FLOOR OR CABLES INSTALLED IN VERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR. EXISTING y 16. FIRE ALARM CABLE INSTALLED IN UNDERGROUND CONDUIT OR OTHER WET LOCATIONS SHALL BE UL LISTED FOR WET DUCT SMOKE SENSOR SIMPLEX 4098-9756 MOUNT TO DUCTWORK o LOCATIONS. X 2 17. FIRE ALARM CIRCUITS EXTENDING BEYOND ONE BUILDING AND RUN OUTDOOR SHALL BE INSTALLED IN ACCORDANCE WITH INTERNATIONAL FIRE CODE (IFC), 2012 EDITION REMOTE TEST STATION W/ LED AND KEY SWITCH SIMPLEX 2098-9806 SINGLE GANG BOX 2 1/2" DEEP o NFPA 70 ARTICLES 760, 770, 725 AND 800 WHERE APPLICABLE. EXISTING ° 18. ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS. INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION AIM INDIVIDUAL ADDRESSABLE MODULE SIMPLEX 4090-9001 SINGLE GANG BOX 2 1/2" DEEP WITH COVER 19. ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE. 20. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. NATIONAL ELECTRIC CODE (NFPA 70), 2011 EDITION EXISTING E 21. 120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING. 22. MAINTAIN 40 PERCENT CONDUIT FILL RATIO AS PER NEC REQUIREMENTS. o RELAY IAM SIMPLEX 4090-9002 4" SQUARE BOX 2 1/8" DEEP W/TWO GANG COVER o 23. EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY, HOWEVER, ANY EXISTING NATIONAL FIRE PROTECTION CODE (NFPA 72), 2010 EDITION CONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. SIMPLEXGRINNELL MAKES NO EXISTING STATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS. O ENCAPSULATED RELAY PAM-1, SPDT W/ LED SIMPLEX 2088-9021 SINGLE GANG BOX 2 1/8" DEEP W\COVER 0 (APC PAM-1) $ JURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. o CHECK WITH THE LOCAL JURISDICTION AUTHORITY FOR MORE DETAILS. EXISTING (� DOOR HOLDER EXISTING SUPPLIED BY OTHERS WIRE SCHEDULE ABBREVIATIONS LEGEND EXISTING N F WF WATERFLOW SWITCH SUPPLIED BY OTHERS INSTALLED BY MECHANICAL CONTRACTOR AC = ABOVE CEILING HT = HEIGHT C = CEILING MOUNTED HVAC = HEATING, VENTILATION, & AIR CONDITIONING EXISTING y E = EXISTING TO REMAIN IMS = INFORMATION MANAGEMENT SYSTEM TAMPER SWITCH SUPPLIED BY OTHERS INSTALLED BY MECHANICAL CONTRACTOR RC = EXISTING TO REMOVE AND COVER MAX = MAXIMUM VS RD = EXISTING DEVICE TO BE RELOCATED MIN = MINIMUM FIRE ALARM WIRE LIST RL = RELOCATED DEVICE N/A = NOT APPLICABLE EXISTING RR = REMOVE EXISTING AND REPLACE W/NEW NAC = NOTIFICATION APPLIANCE CIRCUIT EXTENDER LT LOW TEMP SENSOR SUPPLIED BY OTHERS INSTALLED BY MECHANICAL CONTRACTOR B RUI/N2 COMMUNICATION - 1 PAIR 18 AWG TWISTED OVERALL SHIELD WP = WEATHERPROOF NDU = NETWORK DISPLAY UNIT NON-PLENUM RATED: FPL NON-PLENUM RATED: FPLR PLENUM RATED: FPLP XP = EXPLOSION PROOF NEC = NATIONAL ELECTRICAL CODE EXISTING BELDEN 5320FJ BELDEN 5320FL BELDEN 6320FK NFPA = NATIONAL FIRE PROTECTION ASSOCIATION AREA=0.0350 SQ. INCH AREA=0.0189 SQ. INCH AREA=0.0269 SQ. INCH AFF - ABOVE FINISHED FLOOR NIC - NOT IN CONTRACT WP WEATHERPROOF MULTI-TONE HORN STROBE, WHITE WHEELOCK MTWP-2475W-FW IOB-R WEATHER RESISTANT BOX w I` 8 AHJ = AUTHORITY HAVING JURISDICTION NPU = NETWORK PROCESSING UNIT ro 15 C CITY CONNECT CIRCUIT - 2 CONDUCTOR 18 AWG SOLID ALM = ALARM NTS = NOT TO SCALE EXISTING NON-PLENUM RATED: FPLR PLENUM RATED: FPLP ANN = ANNUNCIATOR PAP = PRE-ACTION PANEL # WALL MOUNT MULTI-CANDELA V 0 RED SIMPLEX 4906-9101 4" SQUARE BOX 1 1/2" DEEP BELDEN 5320UL BELDEN 6320UL / /BMS = BUILDING MANAGEMENT SYSTEM SCC = STATUS COMMAND CENTER O O ° AREA=0.0179 SQ. INCH AREA=0.0179 SQ. INCH CANDELA RATING c CBC = CALIFORNIA BUILDING CODE SLC = SIGNALING LINE CIRCUIT # - CD = (eg. 15CD) CANDELA SMK = SMOKE W Q o D DOOR HOLDER CIRCUIT - 2 CONDUCTOR O AWG SOLID CSFM = CALIFORNIA STATE FIRE MARSHALL SUPV = SUPERVISORY #W� # WALL MOUNT MULTI-CANDELA S V WHITE SIMPLEX 4906-9153 4" SQUARE BOX 1 1/2" DEEP W/ 1 1/2" EXTENSION RING N 9 ON-PLENUM RATED: FPLR CONDUIT ONLY: THHN PLENUM RATED: FPLP / �..�..� � O � BELDEN 512OUL (2) #14 AWG (YELLOW/BLUE) BELDEN 612OUL DET = DETECTOR TAC = TRUEALERT ADDRESSABLE CONTROLLER # -CANDELA RATING, #W - SPEAKER TAP W/4905-9947 ADAPTER SKIRT WHEN SURFACE MOUNTED O 0 J AREA=0.0356 SQ. INCH AREA=0.0097 SQ. INCH (EACH) AREA=0.0330 SQ. INCH DGP = DATA GATHERING PANEL TRBL = TROUBLE 0 J 0 'E EOL = END OF LINE TS = TAMPER SWITCH Q LJJ Q V H AUDIBLE CIRCUIT - 2 CONDUCTOR 14 AWG SOLID EPO = EMERGENCY POWER OFF TYP = TYPICAL Jg JUNCTION/PULL BOX SUPPLIED BY OTHERS SUPPLIED BY OTHERS Ur > ° NON-PLENUM RATED: FPLR CONDUIT ONLY: THHN PLENUM RATED: FPLP FACP = FIRE ALARM CONTROL PANEL UON = UNLESS OTHERWISE NOTED O O J BELDEN 512OUL (2) #14 AWG (RED/BLACK) BELDEN 612OUL FATC = FIRE ALARM TERMINAL CABINET VCC = VOICE COMMAND CENTER END-OF-LINE RESISTOR 3.3K (EOL) SIMPLEX 4081-9002 0 O Q AREA=0.0356 SQ. INCH AAREA=0.0097 SQ. INCH (EACH) AREA=0.0330 SQ. INCH FBO = FURNISHED BY OTHERS VT = VALVE TAMPER J J 04 ********** REFER TO SIGNAL CIRCUIT DISTANCE CHART ********** END-OF-LINE RESISTOR 6.8K (EOL) SIMPLEX 4081-9004 ¢ E= FCC = FIRE COMMAND CENTER WF = WATER FLOW 6.8K SUPPLIED BY OTHERS o K REMOTE TEST SWITCH/LED CIRCUIT - (2) 2 CONDUCTOR 18 AWG SOLID FAA = FIRE ALARM ANNUNCIATOR W = (eg. 1/2W) WATT END-OF-LINE RESISTOR 10K (EOL) SIMPLEX 4081-9008 UT E M - NON-PLENUM RATED: FPLR COND I ONLY: TFFN PLENUM RATED: FPLP FTR = FIRE ALARM TRANSPONDER W/ = WITH N BELDEN 5320UL (2) #18 AWG �WRINITE//BoROWN) BELDEN 6320UL FSD = FIRE SMOKE DAMPER W/0 - WITH OUT AREA=0.0179 SQ. INCH 2 18 AWG RANGE) AREA=0.0179 SQ. INCH - w AREA=0.0055 SQ. INCH EACH ° - 3 c o M NON-PLENUM/IDNET CIRCUIT - 1 PAIR 16 AWG TWISTED OVERALL SHIELD DEVICE ADDRESS N G LEGEND SEQUENCE O F OPERATION c T J NON-PLENUM RATED: FPL NON-PLENUM RATED: FPLR PLENUM RATED: FPLP L ° ° v c a � BELDEN 5220FJ BELDEN 5220FL BELDEN 6220FL z AREA=0.0434 SQ. INCH AREA=0.0249 SQ. INCH AREA=0.0257 SQ. INCH (D o o P MAPNET/IDNET POWER CIRCUIT - 2 CONDUCTOR 14 AWG SOLID Vail Lodge Tower - Sequence of Operations NON-PLENUM RATED: FPLR CONDUIT ONLY: THHN PLENUM RATED: FPLP ADDRESSABLE CARD (IDNET OR MAPNET) SYSTEM OUTPUTS N BELDEN 512OUL (2) #14 AWG (YELLOW/BLUE) BELDEN 612OUL DEVICE ADDRESS FACP Annunciation Notification Required Supplementary °, g AREA=0.0356 SQ. INCH AREA=0.0097 Q. INCH (EACH) AREA=0.0330 SQ. INCH F Controls Z co LD R RELAY CIRCUIT - 2 CONDUCTOR 14 AWG SOLID M2- 1 L U NON-PLENUM RATED: FPLR CONDUIT ONLY: THHN PLENUM RATED: FPLP U) BELDEN 512OUL (2) #14 AWG (YELLOW/BLUE) BELDEN 612OUL ADDRESSABLE DEVICES NUMBERING w AREA=0.0356 SQ. INCH AREA=0.0097 SQ. INCH (EACH) AREA=0.0330 SQ. INCH � E c = oy S AUDIO CIRCUIT - 1 PAIR 16 AWG TWISTED OVERALL SHIELD Y NON-PLENUM RATED: FPL NON-PLENUM RATED: FPLR PLENUM RATED: FPLP `� N o ° L BELDEN 5220FJ BELDEN 5220FL BELDEN 6220FL SPEAKER CIRCUIT r DEVICE DESIGNATOR � o o o g N y 2 AREA=0.0434 SQ. INCH AREA=0.0249 SQ. INCH AREA=0.0257 SQ. INCH I z - `` C-4 a ********** REFER TO PANEL INSTALLATION MANUAL ********** S2- 1 c `� z s I N "' ° V VISUAL/SIGNAL CIRCUIT - 2 CONDUCTOR 14 AWG SOLID a s `� 21 o N S = o I o N N ° a NON-PLENUM RATED: FPLR CONDUIT ONLY:(RED/BLACK)THHN PLENUM RATED: FPLP in N - t " I ° �' � ) # S f E SPEAKER DEVICE E °z' 2 ° s` o _ " " v N BELDEN 5120UL 2 14 AWG BELDEN 612OUL a z s N N g ° > ° a J ° ° CYJ ° E ° o. o E ° N N Z` °' >. a � o = d3 = I $ c o E W AREA=0.0356 SQ. INCH REA=0.0097 Q. NCH ACH) AREA=0.0330 SQ. INCH E ° 3 3 a _ ° ° 3 o ********** REFER TO SIGNAL CIRCUIT DISTANCE CHART ********** a `� _ " _ N N U w ° ° _ `" a ° e E a E � E ° o a c o o c Z F- E ID ° Z ZONE CIRCUIT - 2 CONDUCTOR 16 AWG SOLID CIRCUIT DESIGNATOR E E E _ ° o W ,, ° ; o o - a N U Q U Q U Q Q > U 1.� N H N iU W 03 N 2 "' ° O .°.. N rn NON-PLENUM RATED: FPLR CONDUIT ONLY: TFFN PLENUM RATED: FPLP 4009 NAC PANEL V=VISUAL OR A/V, H=AUDIBLE ONLY) ;� ;� ° E - E N o 2 °' c 3 a BELDEN 5220UL (2) #16 AWG (YELLOW/BLUE) BELDEN 6220UL (WHEN APPLICABLE) DEVICE DESIGNATOR ° ° ° ° ° ° ° N ° ti ° ° a ° ° E r ;, a 6 U U U U U U U = N N N N U L O p O O p 2 L O j c N w AREA=0.0238 SQ. INCH AREA=0.0072 SQ. INCH (EACH) AREA=0.0238 SQ. INCH SYSTEM INPUTS a a Q Q a < Q o a ti o 0 � ri i ti - Q w ° Z A B C D E F G H I J K L M N 0 P Q T U V W X Y Z DRAWN BY: NSW t Of CONDUIT SIZE CONDUCTOR AREA CONDUIT SIZE CONDUCTOR AREA 1 N:V2- 1 1 Manual Pull Station - All Locations x X x x x X X 1 CHECKED BY: SS s 1/2" 0.12 SQ INCH * 1-1/4" 0.60 SQ INCH * 2 Smoke Sensors - All Locations X X X X x x X X X 2 ISSUE DATE: 9/19/13 :5 t N * 1-1/2" 0.82 SQ INCH * 3 Smoke Sensor - Elevator Machine Room X x X X x X x X X X 3 3/4 0.21 SQ INCH VISUAL. AUDIBLE OR A/V DEVICE 1" 0.34 SQ INCH * 2" 1.34 SQ INCH * 4 Smoke Sensor - Elevator Shaft x x x x x x x x x x x 4 JOB#: 5 Smoke Sensor - Elevator Lobby Ground Flr X X x X x x X X x x 5 8 * 40% FILL PER N.E.C. Smoke Sensor - Elevator Lobby Flr 1 - 7 PROJECT#: 419:972539701 0 s y x x x x x x x x x x s THE CABLES SPECIFIED HERE ARE FOR REFERENCE OF REQUIRED 7 Duct Smoke Sensor x x x x x 7 SIMPLEXGRINNELL© 2013 8 Thermal Sensors - All Locations X X X X x X X X X 8 SYSTEM: y ELECTRICAL CHARACTERISTICS AS WELL AS CODE REQUIREMENTS. IDC (ZONE) DESIGNATION DEVICE DESIGNATOR 9 Thermal Sensor - Elevator Machine Room x x x x x x x x x x x s FIRE ALARM SYSTEM " ALTERNATE SUPPLIERS MAY BE SUBSTITUTED PROVIDING EQUIVALENT -1 F 10 Thermal Sensors - Elevator Shaft x x x x x x x x x x x 10 x 11 Thermal Sensors CHARACTERISTICS ARE MAINTAINED. ITEMS SUCH AS CAPACITANCE Z3- 1 - Storage Lockers x x x x x x x x x 11 12 Waterflow - Main X X X X X X X X X X 12 SHEET: y BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL 13 Sprinkler Control Valve - x x x x 13 y TO THE CIRCUIT DESIGN OF THIS SYSTEM INSTALLATION. ZONED INITIATING DEVICE 14 VFD Fault Status Module - M1-125 x 14 15 Internal Current Sensor Fan Belt Broke - M1-126 X 15 16 FACP AC Power Failure x x x x 16 GENERAL INFORMAT 17 FACP Low Battery X x x X 17 18 Open Circuit x x X X1 18 y 19 Ground Fault X X x X 19 a) PO Notification Appliance Circuit Short X x x X 20 N 21 Alarm Signal Silence X x 21 n o ° A B C D E F G H I J K L M N 90Q T U V W X Y Z DRAWING NOTES: '0 s NOTE: Audible Evacuation Signal shall be Temporal Pattern per NFPA 2-2010. w Q * Disconnect power after a time delay equal to the time it takes for the car to travel from the highest to the lowest level plus 10 seconds. o THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. /�-oo� Z M THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. A � � � X NO= N .c a ° DRAWING NOTES: RUN NEW DEDICATED FLOOR VISUAL AND SPEAKER CIRCUIT UP TO 1 NEW FIRE ALARM CONTROL PANEL CABINET LOCATED IN GARAGE. Itw RELOCATE EXISTING SMOKE DETECTOR FROM GROUND FLOOR LOUNGE MM M M -° M 2 TO ELECTRICAL ROOM. E LLI 'm O �� N 'v O FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND aU REPLACE IF REQUIRED. (TYPICAL) Q� co DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES O CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE y oN° a DRAWINGS. PLEASE VERIFY ALL DEVICE LOCATIONS. o°M = M ° U 0 'S V ��U w U nc = N CD W W o D cflDtA E 0 U —0 a m N00 L IOF ° • 3 44967 k U L • • 3 ••; 9/23/13 •:��� ONk- �'`F•'••.....•••'��� 0 6. K 6. K 6. K 6. K 6. K 6. K 6. K 6. K 6. K 6. K 6. K 0 a m VS WF VS VS VS VS WF VS WF VS WF VS N AIM AIM AIM AIM AIM AIM AIM AIM AIM AIM AIM 0 M1-108 M1-119 M1-121 M1-25 1-26 1-39 1-40 M1-41 M1-4 M1-43 M1-48 L O C O a m ELEVATOR #1 M-T ELEV SHUNT EQUIPMENT a 15 2W R ROOM ELECTRICAL M1-1160 M 0 ° ROOM 2 RL S13-2 M1-27 2 V1-2 s 10K S�3-41W S,V M1-5 RL � R13M1-34 S,V a 10K 30 2S,2V 1W O 1. V1-1 JB S13-1 °le ZN153 E S,V 2 0 O 3.3K c 2S,2V BOILER ROOM 0 Y N 3. K 302W d BOILER RELIEF S13-3 VALVE O V1-3 AIM ZN149 ° W ° I� $ u') A2 C�4 0 c w 0 0 ° c w ° Q Q W °� c 0 0 0 J0 E p wQv C� > J O o J 0O > N < E� <O � C � o a c m 3 W c - > VJ N a J C CO O O — 'N C � Z WE �. C a `o m y O) E L a A W m a E N Q � O N z N w Q a N Q ~ 6 0 c U m o a U m PLAN o 0 NORTHc E Y c o BASEMENT DEVICE PLACEMENT PLAN OE Q L Q ~ d U SCALE: 1/8" = 1.0' c O K 0 4 8 16 w of (IN FEET) c° o t o -0 w Y ( ) of E N 0 U w Ulm d . Y O o c N -- m c y v 3 W z DRAWN BY: NSW L CHECKED BY: SS N ISSUE DATE: 9/19/13 J x JOB PROJECT#: 419:972539701 o t SIMPLEXGRINNELL© 2013 E o SYSTEM: N w � FIRE ALARM SYSTEM SHEET: N a` t N N BASEMENT DEVICE `0 3 PLACEMENT PLAN a U U U y 16 a m m N K N Cn c n 0 DRAWING NOTES: w Q U m M THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. FA-101 cx THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. T r 04 O a a � w a m m DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER CIRCUIT TO NEW FIRE ALARM N 1 CONTROL PANEL CABINET LOCATED IN GARAGE. °U") w °\ DISCONNECT HARD-WIRED NAC TRIGGERS FROM EXISTING NAC PANEL M co MM 6 M M m < 2> AND RECONNECT TO IDNET #2 AS SHOWN TO PROVIDE FLOOR SYNCHRONIZATION. ADDRESS NAC PANEL AS SHOWN. O� RUN DEDICATED FLOOR VISUAL CIRCUIT TO EXISTING NAC PANEL Q OO LOCATED IN MACHINE ROOM ADJACENT TO ELEVATOR #3. REUSE ` EXISTING VISUAL CIRCUIT WIRING WHEREVER POSSIBLE. o o � Qom REMOVE AND RELOCATE EXISTING SMOKE DETECTOR FROM LOUNGE moo OO AND INSTALL IN BASEMENT ELECTRICAL ROOM. �w �» - CD REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE o to oco 0 AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER U CIRCUIT. N O REMOVE EXISTING HORN/STROBE AND REPLACE WITH NEW o�o�Pfl0 LIB oA�..... 0 O SPEAKER/STROBE. RECONNECT VISUAL TO EXISTING CIRCUIT FROM ;• % 3 EXISTING NAC PANEL. CONNECT SPEAKER CIRCUIT TO NEW FIRE ALARM CONTROL PANEL LOCATED IN GARAGE. .� 44967 xz .3 •: 9/23/13 .'�`�CC EXISTING FIRE ALARM CONTROL PANEL WILL BE UPGRADED TO A NEW s **06000 o r 0 4100ES. ADDITIONAL BACKBOXES REQUIRED AND WILL BE LOCATED IN \ GARAGE. m 0 DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES E TI u E O CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE \ oc1 ` DRAWINGS. PLEASE VERIFY ALL DEVICE LOCATIONS. N VALET/ 1-7$ :. : 2 M1-107 2 3 CONCIERGE 112-3 . .. . . .. . . .. . . WP 021 2 4 --------------- ------------------ --------------- m 0 M1-81; w 10K SIG3 . :.. . 7 F 4 . . .. . . .. . . . Z 1 . . � � - - - - - - - - - - - - - - - - - - M1 83 .. . .. . .S2 4. 0. :. :M1 117: :. : .. . M1-72 o ELEV PRIMARY JB p� 2 M1-73 p ELEV ALTERNATE ELECTRICAL M2-102 M2-103 M2 g8�K�� 2-105 M2-106 M2-109 M2-110 N�f1 .5 2S,V L B Y 4 O -- o 018 0 6.8 Q 6.8 �""r Ov*6.SK � "•ISAK `+J��r6.8K 1 " 6.8K •2 0 a M1-74 o R ELEV SHUNT TRIP /� V m �/M1-n EI M1-29 AIM POWER MON ', 6.8K � ❑ 25 0 Ml-75 p \ 75 1W \ 1�y / ee=e'a° �. �. LOUNGE. . o o S ELEV CAB LIGHT �---------� � � Jg . .. . . ..`. i i �.. . , .. . , .N1:2-5 € S2 -17 _ 3 5 5 S22 18 O FOOp . .. . _ .N M1 .86 - 75 1W - - ERQNT. pESK :. PREP. : :. : 5 O.: 3 i 6 K 751W. ... . . .. . . ..]U.OMt�ER. . . o OFFICE o --- ,V'. o AIM _ AIM _ AIM _ - O ��� R135 F 1 .8K 1 K 1 6.8 LUGGAG w l� 5 .T :. . ELEVATOR M1282 _ M1.-12Z M1170 \ M1=t20. 1 04 _ S ORAGE. .. M1 87 4 - 024 . 1 - -- 68 \ MECH - 1 ELE ER FATC �. : .. I- - - M1-3; 6 STORAGE 3 M1- 1 79 \. . O - -- 1 I.W . F _- 3 AIM AIM AIM 1OOES N1:2-6 016 6.8 Z s a 11-49 AIM VS VS VS FACP FACP � � $,V. . o III M1-3 2 _ aM NM S22 FACP FACP OL M1-60 �' 6.8K 6.SK TP TPR OHO S22-1 5 t 2 Z M1- p 2 WF 6.8K i i 5 S22-19 S'V _N1'.< . . .. , .. , .. 2 0 SPRINKLER V 2=7. \�\ K JB LOBBY 52-1. 2=107. \\ 2V S,2V1W E EV CON ROL 19 022 Lu Q \\\ 30 N1:5- SPACE AIM 5W Q o \\\ LT 522-14 VS 15: S,Y O 0 TRASH CHUTE aM M2-8 AIM M2-82 AIM -87 AIM 142-88 AIM 2_ 3 M2-94 Im 1"1 0 O S,v 3 1 1 1 1 1 6 1 ,s s2:-8 .: : v w - v .25.W . 1:2. 8.. / ..M1 ..90. .. Q Q o 5 TOILET S2 -13 J y NM 1- GAR GE o S,V 2V:. . :. 15 1..2_9. 008 O p 1W CH 9'-0" # 89 . JB 5� . 0 O Q S22-2:75. J J " a N 1:5=8 2 � j 10K m N 5 1W. : . 1 15 M1- 6 ' . .. . N1:2 10. N T S22-15 S,V: TOILET o N 1:5-2 $ w 4 F 3 3 U 0 0 U) M2-96 L N � m - - -- o 6. K j o y 0 3 z FATC JANITOR CD o 1 19 M21 .V 010 AIM AIM AIM AIM AIM AIM 6.8K m Lu E N can 1 .8K 1 6.8K 1 6.8 1 6.8K FATC 1 •8K 1 M2 j-9S 2 M �94 � o m H U) 6.8K = m J 4 15 2 CL M3-13 N6E8 8 M3-23 M3-,32 M3-33 M2-99 o 1 1 s. 1 - 5 j Oj , N1:2-1 s2- w �� a 5 S22 12 S S2 -9 OFFICE M1-95 MANAGER'S 5 M2-100 2 OFFICE = o y 1 S,V JB V 1 JB JB S 1W O O 1W JB 0� \ 011 L ;. °Q M3-8 : 2S,2V. M3-6 M3-9 M3-1 3-14 M3-16 M3-19 M3-21 M3-24 M3-25 O M3-28 M3-29 M3-31 M3-33 M3-35 - a M3�2 C�13-27. ° x j . . 1 1 1 1 r j 1 �: j T6.8 j j j . . j j 2S.V 0 30 �, s 1- w s 6.8 II �------------------- K 6.8K 8K 6.8K 8K 6: 6.8K 6.8K N.1:4-10 Z 10 Q = co 6.8K o m o M3-1 M3-2 M3-3 M3-4 M3-5 S22-11 J 6.8K .22-5 6.8 6.8K M3-36 1:N o t ri N1:4-3 S 2V 2S 2V S,2V 15 2S,2V O J j 1 1 1 1 �. M3-7 M3-10 3-15 . _ 3-20 j L 5W „- M3-34 6.8K w Y 6.8K 1 1- 6 = N1: -4 M -12 3 17 M -22 -------------------------------- o f CD 1 1 S22 10. 1 1 S _ 1 1 S2 ^� 1 M3-30 1 NS22-3 M3-37 w 0 6.8K 6.8K 6.8K 6.8K 8K 6.8K 6.8 5W .8K 5W 6.8K 5W 6.8K 5W O� w N 5. 6.8K . : 5. 6.8K . : 15. 6.8K 6.8K 15 6.8K ° rn 0 � m w 1:N4 z DRAWN BY: NSW CONFERENCE s a 012 CHECKED BY: SS QISSUE DATE: 9/19/13 t J m JOB#: 2 g PLAN PROJECT#: 419:972539701 o t NORTH SIMPLEXGRINNELL© 2013 E GROUND FLOOR DEVICE P LAC E M E N T PLAN O SYSTEM: ALARM SYSTEM SCALE: 1/8" = 1.0' SHEET: 3 0 4 8 16 at (IN FEET) rn m GROUND FLOOR DEVICE 0 3 PLACEMENT PLAN a U U U y m m _ m N K N_ a 0 - O Q DRAWING NOTES: w co THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. FA-102 THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. r - N d w - w DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE 4 IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL t PANEL CABINET LOCATED IN GARAGE. '� �U M M :o O O go RUN DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM O IDNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE � o .. UPGRADES. aU d REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'� co O SPEAKER/STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND IN o VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. oN° O D-M a _00 M REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE 0 AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER A» CIRCUIT. o co ot E FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND REPLACE IF REQUIRED. UNDO LIEF DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES r'of°AVr O CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE • `' 3 DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT 44967 ; 3 PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. '0% 91/23/13 IFS•••.....•••o� NNA4�� Ll N O V l0 O O d d L O O a o UNIT \ UNIT \ / UNIT / UNIT UNIT 94 192 86 178 E w ° UNIT UNIT / UNIT UNIT 190 188 184 182 STORAGE X ELEVATOR 1-99.2 M1�Tpp ZN142 ZN135 ZN128 ZN121 ZN114 ZN107 ,m ZN15 ZNS ZN1 M1-9 Ts 2 2 2 Ts Ts Ts 2 e LT AIM S S S O . S t M2-5 .. r O N L 3.3K 3.3K (TYPICAL) 3.3K 6.8K .1.88 ❑ 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K ELEVATOR o ZI Mir-.�: C: �❑ 2 ` s;v 1.55 . .:` . .. � V4-1 OK. 515=5: M,P�S V d VV44 L M1-8 S15-1 M2-8 O.K . _ 1�1-5 F .15. 4 . LT AIM Ml WF O 15 6.8K t AIM VS 6.8K M,P,S,V . . . 6.8K M1-6 L i V4�54 4. _ - - _ -3 _ V4-2. �. . M2.1 M2 2 M2' 3 M2=4 M2-6 .. M2 7 .. S15-3 KPAV. . 2 30 M,F,S,V M,P,S;V 2 M2 0'\. . ti s 0 O O O O O. W JB:.. JB JB F 00 O O woo W � o O ono o � a � a I o 0 wa0 ZN64 ZN71 ZN79 ZN86 ZN93 ZN100 ZN57 ZN50 ZN43 ZN36 ZN29 ZN22 () Ts Ts Ts IS Ts Ts Ts Ts Ts Ts Ts Ts O 0o J 2 O O Q 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K o a @ t E m c d o :o UNIT UNIT UNIT UNIT W 193 191 185 183 .� s � y � a = Of o y � UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT a Z 199 197 95 89 87 81 79 177 s E 16 Q a W �v CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. N INFORMATION BASED UPON PANEL PROGRAMMING. o U o N m PLAN o NORTH _ E Y 'c FIRST FLOOR DEVICE PLACEMENT PLAN O U Q L 'C a ~ � SCALE: 1/8" = 1.0' U X a 0 4 8 16 W (IN FEET) o co CD O a co J ?� m co W Y c_ r � Q 3 E 0 � O m d N a 0 � 3 N z DRAWN BY: NSW a CHECKED BY: SS d co ISSUE DATE: 9/19/13 t d JOB#: PROJECT#: 419:972539701 o t SIMPLEXGRINNELL© 2013 L SYSTEM: y FIRE ALARM SYSTEM C N t0 ._ SHEET: y a i Vl N arJ � O) FIRST FLOOR DEVICE 0 3 PLACEMENT PLAN L U U y t0 m N N Cn tWi n 0 M v O 'c Q DRAWING NOTES: W U m FA 103 ° _y - THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. z THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. ¢ t 0 T N a w � m DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE s N 1 IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL PANEL CABINET LOCATED IN GARAGE. '� M M O O m RUN DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM Ta O2 DNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE N o .. H UPGRADES. aU o REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'� cn O SPEAKER/STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND o CD VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. °N° OMM a r^ �, M 00 m REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE 0 AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER CO» CIRCUIT. o cooco E O FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND 5 REPLACE IF REQUIRED. y �N00 Lr�c �R}'' DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES s� ° 9 CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE O• O DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT 44967 ZO PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. moo•;• 9/23/13 ,:��� ss/ONAL E� N O V f6 O d Q d d L O O N _ UNIT \ UNIT \ / UNIT / UNIT / UNIT 294 292 286 280 [ 278 t T C f6 O ❑ ❑ O d UNIT UNIT / UNIT STORAGE UNIT 290 288 284 0 282 0 0 0 ELEVATOR M2-1.4 O E o u o ZN143 ZN136 ZN129 ZN122 ZN115 ZN108 /. 2 ZN16 ZN9 ZN2 E AT TS 2 2 2 TS TS TS 2 TS 3 S S S S t M1 T�.. . . L ❑ 3.3K 3.3K 3.3K �� 3.3K 3.3K 3.3K 3.3K 3.3K (TYPICAL) 3.3K ❑ j ELEVATOR o 00 2 y OO M P,S V V5-1 �� S16-1 M2-17 £ jOK 106 4 ❑ M1-11 1 Q . O AIM WF 6.8K 15 S16-5 AIM VS M,P,S,V 15x5-5 S,V M1-10 6.8K M4=52 M2-1.0. . .. M2�11 : M2-.12 M2-13 V5-3 M2-1'S M2-1.6. V5-2 F F 2 t s1 s-2 V5-4 M,P.S,vO M.P,SV M.P�S.V M,P�S�V M,P�S.V M2-71 w r` 8 2 �/ O 30 15 S16-4 O JB JB JB F V'N Q. 1 3 O3 O O 0 W 0 g �..u..� N a O w O o U ZN65 ZN72 ZN80 ZN87 ZN94 ZN101 ZN58 ZN51 ZN44 ZN37 ZN30 ZN23 cl Q is ? s Zs is 2s ? s 2s is 2s is is 2s O O o Q y _I J cv > 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K o o N D N N T C d V UNIT UNIT UNIT UNIT rWr 293 291 285 283 3 = V! N C O C 2 O `j UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT o z pip ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ y of D a E W �v Q m o N H Z 3 E � U CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. o INFORMATION BASED UPON PANEL PROGRAMMING. o E O O PLAN = y NORTH SECOND FLOOR DEVICE PLACEMENT PLANO 00 SCALE: 1/8" = 1.0' co 0 4 8 16 °o ° � T co (IN FEET) -i M W Y c C) N Q 3 E 0 ON �N ° m Q � 3 m z DRAWN BY: NSW CHECKED BY: SS U) ISSUE DATE: 9/19/13 r JOB#: PROJECT#: 419:972539701 o t SIMPLEXGRINNELL© 2013 SYSTEM: y L FIRE ALARM SYSTEM C H t0 .0 SHEET: ti H V � N N W � SECOND FLOOR DEVICE `O 3 PLACEMENT PLAN L U U y t0 m N N_ K Cn c n Q DRAWING NOTES: W U m FA M -104 THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. M x THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. M . r -- N y DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE 0 N IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL PANEL CABINET LOCATED IN GARAGE. '� mve z O O m RUN DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM Ta O2 IDNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE N o .. H UPGRADES. au o REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'� cn O SPEAKER/STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND o CD VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. N° ° OMM a r^ 00 M m REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE 0 AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER CO» CIRCUIT. o cooco E FIELD VERIFY VALUE OF EXISTING END—OR—LINE RESISTORS AND REPLACE IF REQUIRED. ADO Lrc �p Avr`•'F�s�` DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES • ��� \ 9:° O CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE \ 3 DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT 44967 's ZO PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. :,.9/23/13 ;•' � 0 0 Q n L O O N ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ UNIT V UNIT \ / UNIT / UNIT / UNIT a 394 392 386 380 378 t T C f6 O UNIT UNIT / UNIT STORAGE UNIT 390 388 384 0 382 0 0 MAID. . 0 ELEVATOR 0 o L J M2-24 O Z144 Z137 Z130 Z123 Z116 Z109 /. 0 Z17 Z10 Z3 E A o 3 2 2s 2s 2s 2s is 2s 2s is��(TYPICAL) 2s t Mt-O \3.3K 3.3K 3.3K 3.3K 3.3K —�I 3.3K 3.3K 3.3K ❑ ❑ ❑ ❑ : . u. ELEVATOR Y 2 I7ZL \ M,P,S,V M.1-64. �� O V6-1 M1-13 S17-1 M2-27 0 10K SO 0K AIM WF 6.8K 15 S17-5 AIM VS M,P,S,V ..V6-5. 6.8K 15. M1-12 t d M4=53 2 28 M2-20 : M2-21 M2-22 M2 23 V6-3 M2-25 - M2-26 V6-2.: F F S17 3 1 2 V6-4 - M�P�SV.. M,P,S,V M�P�S.V KRS,V M.P�S,V f` 8 15 S17-4 O O �... JB - F 2 ® 30 Q` Z 1. TL Lf) r 00 O O o Lu W N a O cr O o ❑ IU ❑ ❑ L❑� ❑ � J 0 U Z66 Z73 Z81 Z88 Z95 Z102 Z59 Z52 Z45 Z38 Z31 Z24 () 2s is is 2s 2s 2s ? s is is is 2s 2s O O o Q y _I J cv > 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K o o � R L_ E N N T C d UNIT UNIT UNIT UNIT rWr 393 391 385 383 3 Z5 2 V! N t0 C O C 0 N �j UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT o z 399 / 397 / 395 389 / 387 / 381 / 379 / 377 1u o pip ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ y o D a a° W �v Q rn o N H Z 3 w d U CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. o INFORMATION BASED UPON PANEL PROGRAMMING. � W I= c � E Y 2 .9 = O N PLAN NORTH °a V THIRD FLOOR DEVICE PLACEMENT PLAN O o co SCALE: 1/8" = 1.0' o ° co 0 4 8 16 = � co W Y c (IN FEET) N a o C) oN Q � 3 m o z DRAWN BY: NSW CHECKED BY: SS U) ISSUE DATE: 9/19/13 r JOB#: PROJECT#: 419:972539701 o 0 SIMPLEXGRINNELL© 2013 SYSTEM: y L FIRE ALARM SYSTEM C H t0 .0 SHEET: ti H V � N N W � THIRD FLOOR DEVICE `0 3 PLACEMENT PLAN L U U y t0 m N N_ K Cn c n ° Q DRAWING NOTES: W U m to THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. FA-105 x THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. r -- N y DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE s N IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL �� t PANEL CABINET LOCATED IN GARAGE. '� LOU MM a Ch C, O RUN DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM R O2 IDNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE � o .. y UPGRADES. a C3 O X N REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'► co O SPEAKER/STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND '\ ° to CD a VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. 5<1 O OEM a REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE t= AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER rx Cn» CIRCUIT. o �o� E FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND <s> REPLACE IF REQUIRED. Q,ND 0 L C ° .••oA�i•'•••ysF DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES r��� 9•: s CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE O DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT ;< 44967 PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. ; 9/23/13 •;���� ONAL� a w 0 H C r V R O 2 d d L O O N UNIT \ UNIT \ / UNIT / UNIT / UNIT 494 498 486 480 478 L T c t0 UNIT UNIT / UNIT STORAGE UNIT w 490 488 484 0 482 S MAID.`. D ELEVATOR a 0 c � 2145 2138 2131 2124 2117 2110 Z18 Z11 Z4 € E VA R Ts Z Z 2 2 Z 2 2 3 S s S S S S S s y MT-•103 . . . O \ ❑ 3.3K 3.3K 3.3K ❑� 3.3K 3.3K 3.3K 3.3K 3.3K (TYPICAL) 3.3K ❑ u0 \ //ELEVATOR y M1-65. DO M,P,S'V V10-1 y o S18-1 V10 S18 .4 M1-15 M -37 O1 . . 10K 10K AIM WF 6.8K ® 15 51.8-0 AIM VS M,P,S,V V10-5 S,V \ 6.8K 15. M1-14 F M4=54 2-38 M2-30 .. .. M2-31 M2-32 M2-33 V10-3 M2-35 M2- .. . -. . : V10-2 - F s 1 - c V10-4 M,P,S,V..2 IIARSY ..... M.P:S.V 18-3 - M�P�S,V M.P�S,V S. 8.2 8 (j� 15 S18-4 O ... O :: 30 b LO JB JB JB - F 0 W � woo W g 0 Q c Z67 Z74 Z82 Z89 Z96 Z103 Z60 Z53 Z46 Z39 Z32 Z25 (� Q Lu U Ts Ts Ts Ts Ts Ts Ts Ts Ts Ts Ts O o s oo Q 3 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K o o E N L N � U C d O UNIT UNIT UNIT UNIT W 493 491 485 483 0 0 v � o c UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT o z 497 / 495 489 / 487 / 481 / 479 / 477 s m ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ H rn Ea � W �v Q rn o N H g Z F- CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. w U o � INFORMATION BASED UPON PANEL PROGRAMMING. o 15 � E PLAN Y 1 NORTH F5 0 � L FOURTH FLOOR DEVICE PLACEMENT PLAN Q 6 c 0 ° SCALE: 1/8" = 1.0' O a 0 4 8 16 o tir co (IN FEET) ° co Rd E 0 O cli ti a Q m 3 m z DRAWN BY: NSW t a CHECKED BY: SS U) ISSUE DATE: 9/19/13 t JOB#: PROJECT#: 419:972539701 $ t SIMPLEXGRINNELL© 2013 SYSTEM: y L FIRE ALARM SYSTEM C � t0 .0 m SHEET: ti N FOURTH FLOOR DEVICE `0 3 PLACEMENT PLAN uj N U U � R N m R N Cn CO n M v O Q DRAWING NOTES: w FA-106 z co THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. = THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. CV 0 w DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE s N IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL �� t PANEL CABINET LOCATED IN GARAGE. '� LOU MM a Ch C, O RUN DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM R O2 IDNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE � o .. y UPGRADES. a C3 - O X N REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'► co O SPEAKER/STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND '\ ° to CD a VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. oN6 O OEM a REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE t= AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER rx Cn» CIRCUIT. o �o� E FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND REPLACE IF REQUIRED. �PD0 L/c ° ono•,,.see •. �s DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES ;• �° 00 y O CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE `� 9 ' 3 s �¢ 44967 DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT ;--1 k; PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. �o:•• 9/23/13 s�DNA �� o � ° 0 Q a L O O N UNIT \ UNIT \ / UNIT / UNIT / UNIT 594 592 586 580 578 t T C t0 UNIT UNIT / UNIT STORAGE UNIT w 590 588 584 0 588 s 0 ELEVATOR w MAIII . . . o O o �J M2-44 0 Z146 Z139 Z132 Z125 Z118 Z111 % 2 Z19 Z12 Z5 € E VA R O 3 2 . 2S 2S 2S 2S 2S 2S 2S Ts��(TYPICAL) is M1-104 . F \3.3K 3.3K 3.3K 3.3K 3.3K n 3.3K 3.3K 3.3K �. ELEVATOR o °0 z y M,P,S,V Ml-66 Do V11-1 y S19-1 M2-47 0 M1-17 1 Sig Sig 1 O a O AIM W 15 0K 110K 6.8K 1 IM\ A VS ,P,S,V V - 6.8K SV N 15. M1-16 / M1-55 - F M2-40 M2-41 M2 42 M2-43 M2-45 M2-46 .48 n F 15 uS1933 15 h -48 V11-4 M,p,S,y 2 M�P,S,V M,P,S,V M,P; V M,P,S,V V11-2 M2 7 f` $ J� ❑ JB , JB - JB - F LO I L� O 3 0 � \ 0 0 t WN W Q s 0 � 0 C� _j o Z68 Z75 Z83 Z90 Z97 Z104 Z61 Z54 Z47 Z40 Z33 Z26 Q TS 0 o 2 TS 2 Ts 2 TS 2 TS 2 TS 2 s 06 Q 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K o E N L N � U C d O UNIT UNIT UNIT UNIT W 593 591 585 583 0 0 v o c 2 ?3 UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT o z 597 / 595 589 / 587 / 581 / 579 / 577 m ]7 ❑ 11❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ H � a � W �v Q rn o N H g Z � E CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. o INFORMATION BASED UPON PANEL PROGRAMMING. o o � E N U � d � m r PLAN y NORTH o ; x (. FIFTH FLOOR DEVICE PLACEMENT PLAN ! o V L V O C co SCALE: 1/8" = 1.0' ; Y 0 0 4 8 16 U) N (IN FEET) � - o cli ti a Q m 3 m z DRAWN BY: NSW t a CHECKED BY: SS U) ISSUE DATE: 9/19/13 t JOB#: PROJECT#: 419:972539701 $ t SIMPLEXGRINNELL© 2013 SYSTEM: y L FIRE ALARM SYSTEM C � t0 .0 m SHEET: ti N 2 N FIFTH FLOOR DEVICE `0 3 PLACEMENT PLAN uj N U U � R N m R N Cn CO n � v O Q DRAWING NOTES: w FA z co —107 THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. = THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. E CV w DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE s N 1 IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL �� t PANEL CABINET LOCATED IN GARAGE. '� LoU MM a Ch C, go DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM R O2 IDNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE � o .. y UPGRADES. a C3 O X N REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'► co O SPEAKER/STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND '\ ° to CD a VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. ~C 5<1 O OEM a REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE t= AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER rx Cn» CIRCUIT. o �o� E FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND 5 REPLACE IF REQUIRED. 0 �•• 6600.lD•A•sF d DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES �� 9• 3 CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE 6 DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT 44967 ,� t PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. -5• 9/23/13,;����0-.600020606 N, 2 �ss�ONAL I J o 0 Q a L O O N UNIT \ UNIT \ / UNIT / UNIT / UNIT 694 692 686 680 678 ° w T C t0 O ❑ ❑ O UNIT UNIT / UNIT STORAGE UNIT w 690 C7-1 684 0 688 s NAID:. 0 ELEVATOR 0 o �J M2-54 O o Z147 Z140 Z133 Z126 Z119 Z112 / O Z20 Z13 Z6 € E 3A R Z 2S 2S ? S is 2S ZS 2S 2S 2S t M1--.105 . ❑ 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K (TYPICAL) 3.3K ELEVATOR o t o� \ Y 8 M1-67,.. : Uo V12-1 0000 . . . o S20-1 .M2-57 M1-19 1 11 K 100 O O AIM WF 6.8K 15. S20-5 AIM VS V12-5 \ 6.8K 5. M1-18 , F M1=56 F -58 M2-50 .. .. M2-51 M2-52 M2-53 V12-3 M2-55 M2-56.. . .. 2' V12-4 2 — � V12-2 8 2 O 2 Z :. Z :... 0 330 Z Z S20-2 15 ti JB 0 JB 0 . . S 0 L 2 O O O o � N W Q O C r n OOf 0 J ❑ ❑❑ �❑� 1 ❑ � ❑ Q W Q O s Z69 Z76 Z84 Z91 Z98 Z105 Z62 Z55 Z48 Z41 Z34 Z27 (� Ts Ts Ts Ts Ts Ts Ts Ts Ts Ts Ts O O Ts O O Q 3 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K o � L E N N O U C d O UNIT UNIT UNIT UNIT W 693 691 685 683 0 0 v � o c 2 ?3 UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT o z 699 / 697 / 695 689 / 687 / 681 / 679 / 677 s m ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ H � a°a � W �v Q m o N H g Z � E o CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. w o INFORMATION BASED UPON PANEL PROGRAMMING. <n W € E N PLAN ° NORTH L F5 0 a U N SIXTH FLOOR DEVICE PLACEMENT PLAN O m32 SCALE: 1/8" = 1.0' °o ° I' 0 4 8 16 = � co W Y c "' (IN FEET) ° o r N Q O cd . c O ti cli c ` a Q m 3 m z DRAWN BY: NSW t o a CHECKED BY: SS U) ISSUE DATE: 9/19/13 t JOB#: PROJECT#: 419:972539701 $ t SIMPLEXGRINNELL© 2013 SYSTEM: y L FIRE ALARM SYSTEM C � t0 .0 m SHEET: ti N 2 N SIXTH FLOOR DEVICE `O 3 PLACEMENT PLAN LU N U U � R N m R N Cn co n = v O Q DRAWING NOTES: w FA z co -108 THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. = THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. CV 0 w d DRAWING NOTES: RUN NEW DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS, FUTURE 1 IDNET AND CO DETECTOR POWER TO NEW FIRE ALARM CONTROL � � L PANEL CABINET LOCATED IN GARAGE. '� LOU M CD C7 M -° RUN DEDICATED FLOOR SPEAKER AND VISUAL CIRCUITS AND FUTURE MM O IDNET AND CO DETECTOR POWER IN CORRIDOR FOR FUTURE Z .. Ll- UPGRADES. ri X REMOVE EXISTING CORRIDOR SPEAKER AND INSTALL NEW �'� cn O 3SPEAKER STROBE. CONNECT TO NEW FLOOR DEDICATED SPEAKER AND '� o / \ u VISUAL CIRCUIT. INSTALL NEW SPEAKER/STROBES AS SHOWN. co CD °N� � D co M a REMOVE EXISTING AUDIBLE AND VISUAL CIRCUIT FROM EXISTING DEVICE =&M � � 2 AND RECONNECT TO NEW DEDICATED FLOOR VISUAL AND SPEAKER a c>» CIRCUIT. o too G� S 5 FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND REPLACE IF REQUIRED. �,PpO LICE o ono., DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE 44967 t OO DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT PROGRAM INFORMATION. PLEASE VERIFY ALL DEVICE LOCATIONS. �o .,.9/23/13 �FSS/DNAL n L_ O N C O r V N O O d d L O AIM WF 101-46 &8K M1-45 AIM VS &8K ❑ ❑ AIM LT UNIT \ UNIT \ / UNIT / UNIT / UNIT M1-22 AIM WF 6.8K 794 792 786 780 778 P M1-21 6.8K T M1-20 AIM VS 6.8K UNIT UNIT / UNIT STORAGE UNIT 790 788 784 0 782 0 2 1 mA D ® ELEVATOR 101-28 o R ELEV SHUNT TRIP -59 M1-7 ZN1 101- 1-23 101-24�� o L J 102-64 0 TO AIM AIM VS 6.8K a ZN148 ZN141 ZN134 ZN127 ZN120 ZN113 /.. 2. 2 DAMPER ZN21 ZN14 ZN7 LT ELEV CAB LIGHT € O V3 2 2s 2s 2s 2s 2s 2S 8 1-32 2s !K<�>(TYPICAL) 2s 101--.106 VS 6.SK❑ 3.3K 3.3K 3.3K 3.3K 3.3K 0 3.3K 101.-�31 AIM 3.3K 3.3K ❑ ELEVATOR � u, a N OO2 M,P'S,V 16-1 101-68. . �0 S21-1 M1-38 S21 1 1-37 O TO DAMPER 0 10K 10K O 15 1-36 S21-5 S V \ M,P'S'V V16-5 \ g / / \ / \ / \ / \ / 1 R135 15. F 101=57 - 102-60 .. . 102-61 102-52 _ 102 63: . 102-65 102-fib. \ F S21-3 _ V16-4 P Y. 2 P V . P V- P V V ❑ 2 M. 5, M, .S, M. .S, 2 30 M, A 2 M.P'% Z S211 2 \ ELEVATOR 15 S21-4 O 0 0 0 Q O ' JB..... JB jg .F'. 2 2 76' � Lf� CO . . - ... 101-30 � M2-111 0 ❑ 2 HALL / o 0 3 O 15 Op t O$ 005 KITCHEN 2 O 0 g FOIL 002 0 BATH 3 LAUNDRY L1J Q a a 015 M2-115 O 009 O �� O Of ❑❑ O$ WR BATH 1 ❑ �+ ~ J O T ZN70 ZN77 ZN85 ZN92 ZN99 ZN106 ZN63 ZN56 25W S9 C 0 6 3 012 MO 14 007 25W > J $ 2S 2S 2S 2S 2S 2S 2S 2S O o y .25W S CLO. CLO. 1 liw S S 013 008 S9 $9 O CV > a 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K 3.3K UNIT 777 e a BED 3 BED 2 BED 1 LIVING a a` 014 011 006 003 N � 1; d 'v UNIT UNIT UNIT 793 791 785 .3 o `o 102-113 M2-112 ILI Z UNIT UNIT UNIT UNIT UNIT OS OS � c 799 / 797 / 795 789 m ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑Ll ❑ w m cl) W �v N Q O O Z 3 -E O � � CURRENT INTERNAL UNIT CONFIGURATION NOT KNOWN AT THIS TIME. o INFORMATION BASED UPON PANEL PROGRAMMING. � w € T ° .Q N C E U O 101-112E H&V UNIT SHUTDOWN 101-113 o SHAFT FAN VFD OVERRIDE ° 101-114 AIM 6.8KSHAFT FAN FAULT y d M1-115 AIM CURRENT SENSOR M Q uj a 2n ZN78 2 IN ATTIC o ° ;= co 3.3K J �,.� w Y N PLAN C) NORTH w - N = w W SEVENTH FLOOR DEVICE PLACEMENT PLAN O a z DRAWN BY: NSW SCALE: 1/8" = 1.0' CHECKED BY: SS 0 4 8 16 ISSUE DATE: 9/19/13 (IN FEET) JOB#: PROJECT#: 419:972539701 a t SIMPLEXGRINNELL© 2013 E SYSTEM: ` y L FIRE ALARM SYSTEM C N t0 .0 SHEET: H N N Of � SEVENTH FLOOR DEVICE `O 3 PLACEMENT PLAN LUa U U U y t0 9 m N c O t Q DRAWING NOTES: w FA-109 M THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. Z THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. N d m � w 3rd FLOOR ZD, ZN66 ZN3Aw Z I DRAWING NOTES: N Z ZN73 0 ZN1G�Z ;c Z FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND 3.3K 3.3K 1 0� Z ZN81 ZN17Aw Z REPLACE IF REQUIRED. (TYPICAL) w 3.3K 3.3K o o Z ZN88 O ZN24im- Z M M vvy 3.3K 3.3K Z ZN95 ZN31 Z I M M R 3.3K 3.3K Z ZN102 ZN38 Z 9 3.3K 3.3K z S _ _ _ _ ZN45 4cz 0 ..CL LL - - - - - - - - - - � - - - - JS10 O ZN52 Z ` CD 3.3K O d Z ZN109 ZN59 Z U 9 x ri Z ��33K 3.3K S �]'+ W73 31K S6 _ - - - _ _ - - - - 1 0 co Z A3.31K 10K JWV- M I \ ° AAA ZN123 �' vvv 3.3K IDNET M2 I 0 N° T Z ZN130 M vvv 3.3K IDNET M1 N as O co M a Z ZN137 Ol S17 rS m co Z 3.3K 10Kr - - - - -U- - - - - - - - - 2S,18Z v g�w V � 3 3K 4 10K P I 3S,26Z N a,Z CO POWER 2M N N w w a D cflDtA 5S a R,2S,3OZ V� IDNET M I 5V R U 2P w M 2 0 ,N90 LIEF 2nd FLOOR I ..•••••.A s y Z ZN65 ZN2 Z I O�.•'pAV�6j '•. F 3.3K 3.3K V �J • Z ZN72 ZN9 Aw 3.3K 3.3K Z 80 O ZN16 kZ 3 Z 3.3K 3.3K Z :¢ 44967 �: Z 3 3K7 O Z3.3K Z O •. .• •G< 'VV� �' 9/23/13 Z 3.3K 3.3K Z I �FSS�DNAL ZN101 ZN37 y 3.3K 3.3K - - - - - - - -- - = =S� - - - - JS10 O Z3.ZN51 3K Z - - - 3.3K Z ZN108 ZN58 Z ° A3.3K 3.3K r t ZDA Z W\h331K5 10K � - - - M -- - - - - I o ��3 3K 2 IDNET M2 Z "ZN129 IDNET M1 �M 3.3K O1 ZhZN136 Sib AA- - - - -(�5- - - - - - - - Z:), ZN143 V5 10K V 2S,21Z ��3.3K 10K I 4S,32Z V CO POWER - b�P - 2M 2S,37Z y M 6S R,2S,36Z IDNET 6V s 2P M c C>61 1st FLOOR Z ZN64 ZN1 4cz .0 Z 3.3K 1 3.3K Z I ZN71 ZN8 E 3.3K 3.3K .y Z ZN79 ZN15 4CZ 3.3K 3.3K v N Z ZN86 ZN22 Z t 3.3K O 3.3K Z ZN93 ZN29 4Z Y 3.3K 3.3K N ZDA O ZN36 Z N 3.3K S 3.3K 3.3K Z I ZN43 -- - - - - - - - - � - - - - 510 3.3K Z I - - - - - - - - - - - - - - J ZN50 3.3K N ZDA ZN107 ZN57 Z h3.3K 3.3K t Z ZN114 M IDNET Ml "Z3.3K of Z "ZN1 1 IDNET M1 c ui g ZD. 10K 8 O r - - - - -U-S- - - - - - - -S15 L0 2 ZDA ��3N3K5 V4 y 2S,24Z _� € 10K I 4S,38Z r "3.3K 2 CO POWER - b�P - I 2M O 0 c 7S o V IDNET M N p R,2S,42Z P M O o 0 0w O E 0 GROUND FLOOR - ,,u LS8 M I p w Q ° 1OK V N1:2 M M I 0 0 > J 10K V N 1:4 CONNECT EXISTING NAC PANEL 314 _ _ _ _ _ S_ _ _ _ _ _ __ _ 101 TO EXISTING IDNET M2 1 O�V� J O N rr V Nl: 10KA%- - - - - -6C5 - - - - - - - - I o V4 4cV o 10K I N a CO POWER -6( - W 4100ES 4100ES 4100ES M IDNET c REMOVE EXISTING HARD-WIRE o s co NAC PANEL TRIGGERS I r J 2S,2B I I o o z A2 A2 5 O z 2M I 2Mi D WE m 3V I y Jt N a m a 4009 I E E 16 N EXISTING y UPGRADE UPGRADE UPGRADE I c Q # EXISTING FACP EXISTING FACP EXISTING FACP I .E ~ V NAC PANEL O y J 120 VOLT AC I 120 VOLT AC 120 VOLT AC 120 VOLT AC CAT5 CABLE ETHERNET DROP I w I TERMINATE W/RJ-45 FEMALE JACK EXISTING CIRCUIT N1:1 0 UP BUILDING AT ELEVATOR #3 I I c RJ-31X JACK I e SUPPLIED BY EC 2 PAIR TELCO I v E LINE 2 NTNG TELEPHONE TO MO BOARD I I U c 2R------F I CD M 14' RJ45 CABLE (2080-9047) SUPPLIED WITH PANEL M 2P RJ-31X JACK 9S 12S---.b I 9V LINE 1 SUPPLIED BY EC 2 PAIR TELCO 8y w N N I 10S TO TELEPHONE 2P 0 I 14' RJ45 CABLE (2080-9047) MOUNTING BOARD M o ° t cr) J p 0 v I SUPPLIED WITH PANEL I m w Y c Z cn CD c Q 3 E NL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - M wa CD R,3S,42Z I c Y N w z 2S,43Z 2S,44Z I I 2S,24Z DRAWN BY: NSW ' TERMINAL TERMINAL TERMINAL TERMINAL /-R,3S,25Z I L CABINET CABINET I CABINET CABINET CHECKED BY: SS ~ I ISSUE DATE: 9/19/13 Q (OLD TPR 103) (OLD TPR 104) (OLD TPR 102) (OLD TPR 101) I �° JOB#: 40--2-16/2 TPS (2S) C�--3-16/2 TPS (3S) I C�-4-16/2 TPS (4S) +---3-16/2 TPS (3S) I PROJECT#: 419:972539701 o t 88#16 (44Z) 86#16 (43Z) r76#16 (38Z) 7r_25#2#14 1 6 TH(2H5N Z)(R) 9 SIMPLEXGRINNELL© 2013 - 2#14 THHN (X) SYSTEM: t 2 S FIRE ALARM SYSTEM ` Z V R Z SHEET: N M N N BASEMENT I BASEMENT-3RD FLR RISER o 3 0 10,AM- - - - - -O5- - - - - - - DIAGRAM a= ZDA ZN149 M R Zh IDNET M1 3.3K O1 Z N "ZN155 ZN153 00 ° N 3.3K O 3.3K R I L a o RELAY 101-104 o Q il3 vvv- -- - _ 5- - - - - - - - DRAWING NOTES: F o M i1oK V THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. FA-201 Z N M THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. ¢ r IDNET it T N d y - w a DRAWING NOTES: FIELD VERIFY VALUE OF EXISTING END-OR-LINE RESISTORS AND CD REPLACE IF REQUIRED. (TYPICAL) u) w �\ oo M M a ATTIC 5 MM ZN150A� 6i N E 3.3K N z Z ZN78 ZN151 O � R 3.3K 3.3K RELAY 104-103 ZN152 ` � CL LL x Z 3.3K � U O R 3Z E ri ��, �n F� o 7th FLOOR Z ZN70 y _ QoL L QN Lo a 3.3K as O-M M Z ZN77 =Ov ce s 3.3K Z ZN85 v w v A2 ZDA ZN92 1 N d w w a Z 3.3K O C Zo 0cn ZN99 E 3.3K Z ZN106 ZN7jvw Z w 3.3K 3.3K - -- - - - - - - - - -5� �`SOK O 3N3K�� Z Q,�DOLI�F s - - - - - - - - - - - -5 S10 ZN21 Z �O••...... �10K 3.3K � �• ppV! ••C�� ZDA A ZN113 ZN56 Z Z �N120 O1 N63Aw Z 'Q 44967 G• 3 33K 3.3K ;� k; ZDA ZN127 S5 S L - - - t Z "ZN134 O IDNET M2 M O,c ••• •� �`3.3K 10K�1r - - - --- - - - - - �'•. 9/23/13 .�k,� Z ZN141 IDNEIF M1 M FSS�0fVA1.E��\ "3.3K o ZDA wZN148 S21 - - - - - -d-S - - - - - - - -- - 6Z 3.3K 10K 1 - - - - - - -- - - - - � wo,1 110K rV 1 2MZ 2S,7Z - - - - - - - - - 1OK CO POWER R,2S,6Z V IDNET M S V a P 0 M = 6th FLOOR 1 Z ZN69 3.3K Z A A A ZN76 Z 3.3K ZN84 Z 3.3K O ZN91 I 3.3K o Z ZN98 ZN6�� Z N 3.3K 3.3K 1 Z ZN105 O ZN13 � Z 0 3.3K 3.3K 1 = - - - - - - - - - -5� - - - - -I 3.3K�� Z E S S9 rS .0 - - -- - - - - - - - - - --I 110Kivw- - - - - - - - - - - Z6 - - -- - - - - - -5� - ZN27 Z S - - - �S10 UK Z A2 - - -- - - - - - - - - J O ZN34 ZDA 3.3K w" Z 1 N ZN112 ZN41 1 t 3.3K 3.3K - Z ZN119 ZN48 Z Y W0 3.3K 3.3K = ZDA wZN126 O ZN55 Z N 3.3K 3.3K ZDA ZN62 4CZ 3.3K 3.3K Z ZN140 rS - - - - - r Z W/�3.3K S5 r - - - - �Jr-- N S -wZN1 7 L - - - M- - - - - - - 1 1 - - -- - - -- - - - - - IDNETM2 1 S M - - -- - - -- - - - IDNET Ml w I� - - - - - - - - - -5� - - - - -I S20KAMr - - - - 5- - - - - - - - C.0 g S12 V S,9Z i�: - - - - - - - - - - - - - - J 110K 1 S,8Z w V CO POWER - GAP - I 2M O O c 2S,13Z V N1:1 IDNET M 2V p o R,2S,12Z I P wQ < M W 0 r � O w 1 O 0 5thFLOOR z N68 ZN5 Z 1 V ~ T Z ZN75 O ZN12 Z 6 3.3K 3.3K�M O 0 J Z ZN83 ZN19 Z O 3.3K 3.3K�� � O Q J CV Z ZN90 O S2 S IN 10K AAAr Z ZN97 ZN26 Z 1 0 0 3.3K 3.3K 1 E s Z ZN104 O ZN33 Z N � a 3.3K 3.3K S _ _ ZN40 Z 0 - - - - - - - - - - - - - g S10 33K Z 3 ` W - - -- - - -- - - � � - J ZN47 = Z UK Z o 0 -i ��3.3K 11 Z3.3K Z W07N118 ZN61 Z N z Z 3.3K 3.3K M 1 WE ZN125 3.3K O IDNET M2- 1 0 o Z "ZN132 1 IDNET M1 M y w UK rr o Q Z "Z3.31 K9 19 AAA- - - - - -!-S- - - - - - - - 2S,12Z E ° ZDA -wZN146 V1 1 V I S,14Z Z R Q V 3.3K 10K rrP 2M O L CO POWER - 6 - 1 y N1:1 M 3S 2S,19Z IDNET 3V o 0 R,2S,18Z I P c E M Y o O N 4th FLOOR 1 Z ZN67 ZN4 Z Q ~ d UK O 3.3K AAAr U Z Z ZN74 ZN11�� 9 3.3K 3.3K o N Z ZN82 ZN18�� Z N Z UK O 3.3K Z o ZN89 Z N 2 5 O 3.3K UK��r OJ co Z ZN96 ZN32 4cz i ? � 3 UK UK Z ZN103 ZN39 Z o E w CD N 3.3K O 3.3K Z L - - - -- - - - - - -S f ,_ ZN46 ° G) S10 UK qD - - -- - - -- - - ZN53 Z w 3.3K ZDA 10 Z .0 201 3.3K 3 3K DRAWN BY: NSW Z - ZN117 S7 S E Z WV`3.3K 10K 'M- - - - M� - - - - - - 1 CHECKED BY: SS ai 15 J Z "ZN1 4 IDNEIF M2 1 ISSUE DATE: 9/19/13 O L 9 -wZN131 IDNFf MlM JOB#: Z ZN138 S18 S PROJECT#: 419:972539701 $ O L 4`3.3K 10K�� - - - - - - - - - - - - - 2S,15Z SIMPLEXGRINNELL© 2013 Z `3.3K 5 110K V I 2S,20Z SYSTEM: t V CO POWER - l5c - I 2M FIRE ALARM SYSTEM 2S,25Z 4S � Y V IDNET M 4V 2S,R,24Z I P SHEET: 3 M a w N N 4TH FLR-ATTIC RISER `0 3 DIAGRAM a U U U y 16 a m m N K N Cn c n 0 =) -2 DRAWING NOTES: w Q U m M THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. FA-202 THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. < T r - 0 a 04 a a � w a m SYSTEM CONDUIT \ o 3/4" MINIMUM DRAWING NOTES: (2" CONDUIT SHOWN) EXISTING 41000 FIRE ALARM PANEL WILL BE UPGRADED TO A N OO 4100ES VOICE PANEL. EXISTING CABINET WILL BECOME 2ND °U") CABINET TO FIRE ALARM PANEL. '� co Ch Ch a DO NOT LOCATE POWER-LIMITED WIRING IN THE SHADED AREAS M° OF THE BACKBOX, THIS AREA IS RESERVED FOR NON-POWER z N LIMITED CIRCUITRY SUCH AS AC POWER, BATTERIES AND CITY TO TELEPHONE DEMARCATION POINT I I CONNECTION. O a_" 44 Q C3- x TO NEW TRANSPONDER IN GARAGE ' �o s FROM NEW TRANSPONDER IN GARAGE <N U') T �V Q o ® V O(] ..•.(•�. u') 14 TZ4 M FUTURE U t J"FERRITE BEAD W sse sea " .5.{ R , z > as I p� to 0-6038 1 0DUAL 1 0 RS-232-C -7 0 O c)S(y) OTHER BD. z � s "1112 E 0 � ° CPU MOTHERBOARD m Nx ` �DO LICs 4100-6052 A°O- °O EVENT 2 Cn z o a w>n N O O f1N„ REPORTING a A• 00- DACT 1 3, O• 3 00 O MouNrs ON Pt 32 N ® SYSTEM POWER SUPPLY - 00 BRACKET N 120VAC 60Hz :Q 44967 1 s�am s�x. ue,n, j PJ,J���IIIT������TT���T�-��������I •� �[• O Oz suOry O O O 1 g O °OO O O O O O O P3 Z IIIY����mmm-1111 •.•9/23/13 •;`��c, SN4 4 C S Y OPB Ylttrl0ls m er 1-I. 6 I�xX� .s,Exw S ONAI_ a awulxSS O 6f xl x N Net . MNlxxx.N Y b I x x.r.r I l x.i l x lN l n I.N I x l l x Y.x I r.InI.x1IlI..I r x 1.E INx lixxb.lIxr gM •iOadt n He.Ab!NN eNed Sll..,! n NN !1..Yllx. 00 New to 31—.� Pr AYx` m i CO � 0 .... oao aE� AAk U AUX1 rss.+a B.�P3 impl©c 4100® �� d �� an ® Q 666 996 O �' O O O t 0 N �T L OS Q 9 FROM NEW TRANSPONDER IN GARAGE- TO NEW TRANSPONDER IN GARAGE TB 0 N 0.4-t@ IIX IIIFI6NE f0 1 2 3 4 5 8 7 8 9 10 ®mmo < ammoa <® ® ® tat ° -O RISER 1 RISER 2 0 ............. 0 m m 9 m m 9 m m o NAC 1^ NAC NAC 0 4100-9620/-1210 1 2 3 s O © O O ® ANALOG AUDIO ' m CONTROLLER e Ps•• c O ® 0 ® O ® o P I C O ]@ O label O loyal INPUT OPTION CARD Pt. :- Label Loyd n PORT 1 :: 0 0 O O ® O L. ® O Loyd L. F Iabd Label �PS na 4100-6079 O�® O L. O ® FIRE PANEL INPUT OPTION CARD :: INTERNET INTERFACE O SP°` a O O L, PORT z f 0 P © 0 Law m lard Wbd Label Pa n IayN 0 label �acAi sPEANEa/IYC o 4100-1326 O �� ® ® REMOTE MICROPHONE LJR o FLEX 50 a ® label p p LI < C m � WATT AMP � y 25V RIMS t 5 4 3 2 1 c TB2 A c O!IP6 YIY IM ® ® uj 1_ U O � O w C 0 d w 0 Q O W Cl 0 Lu 3: 0 0 c 0 0 0 1 � ®2 Ml J O rn Ll ®3 GROUND (1 Q w v > ( , 8 ®4 ausr U !n PANEL MOUNTED PRINTER O 0 J 4100-1293 0 y �N J JJ N > o T _A T �P4 N N iICLPJ C d O C C W 3 > NOT USED � O sanrs :NoT usm N � v 5o COAtlA N c J_ - R4 VDC p C O ,c �j N C 6 z CD ° a) .O (n) (n) a M 0 > Fire Control y a mo U) N CONNECT TO z 120VAC 60HZ MOUNTS TO BACKBOX d t v co r000 0 r000 0 W Z 0 0 E 0 0 o+ - + O O o 0 w Q � U) F V V O I —o Lu m 50 Ah BATTERY 50 Ah BATTERY N ¢ o 2081-9296 2081-9296 N w N m c 5 O o c . m a° v m ; m m W y z DRAWN BY: NSW ® CHECKED BY: SS a ® ISSUE DATE: 9/19/13 t JOB#: PROJECT#: 419:972539701 $ O L SIMPLEXGRINNELL© 2013 w SYSTEM: N w � FIRE ALARM SYSTEM SHEET: y v z N N C O) N � FACP PANEL DETAIL 0 3 m m a t U j R N m m IY N U) l7 FIRE ALARM CONTROL PANEL 0 = a CABINET # 1 (EXISTING CABINET WILL BECOME #2) DRAWING NOTES: m ° M GROUND FLOOR OFFICE THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. FA-501 Z v SCALE: NTS THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. CV O a � � w a m N FROM FACP IN OFFICE ® N TO FACP IN OFFICE 0 OO L TO EXISTING ZONES TO EXISTING ZONES �� �� FERRITE eEAOS TO 1ST FLR VISUALS - V4 TO 4TH FLR VISUALS - V10 co TO 2ND FLR VISUALS - "V5" TO 5TH FLR VISUALS - "V11" MM TO 3RD FLR VISUALS - "V6" TO 6TH FLR VISUALS - "V12" 6i iBl nl 181 NN 19, 181 181 o a ® o o a o o o ® ® g +1 1-1 3 4 8 101111 12 17 181119 20 ® 73 74 75 78 81 82 83 84 90 91 92 97 98 99 100 a105 1 107 108 B+8-A+A-B+B-A+A-B+8-A+ B+B-A+A-B au 4100-5005 4100-5005 4100-5005 NAC4 NAC5 NAC6 4100-5005 4100-5005 4100-5005 4100-5005 4100-5005 NAC15 NAC" KC12 O x m 8 ZONE 8 ZONE 8 ZONE nn 8 ZONE 8 ZONE 8 ZONE 8 ZONE 8 ZONE V 4100-0620 CLASS B CLASS B CLASS B V CLASS B CLASS B CLASS B CLASS B CLASS B �+ im MOTHER BD. MOTHER BD. MOTHER BD. ® MOTHER BD. MOTHER BD. MOTHER BD. MOTHER BD. MOTHER BD. ~ BASIC TIC Ff A 1 1 A 1 1 A ® 1 A 1 1 A 1 A 1 A 1 A - 1 1 I I I © e ^` �O �_2 P2 P2 P2 P2 P2 0 1 1 2 3 4Z 8 0 11 12 : 12 3 4 5 6 7 8 9 10 11 112 N m m a a m m a c m I + ° : m m a t D 00° W.C7 NACB .IT ° NAC13 .11 14 5 M Pz 24�O°°°0 0 O /9801a um 1 ,J1 1 1 J1 11P1 J1 J1 , JI 1 J1 , J, , J1 O�P] 24C =°°°° w P1 PI J J °mpJ 1p, P1 J Pt J 11 J P1 ~ LLf n Lu .QP5 ,,0, 4100-5115 acPS o 0P4 1UP4 _ 0^......O 1 1 I XPS 1 1 1 1 1 410XPS115 o Z> P2 VJ U P3 P3 P3 ® IT7;I P3 P3 P3 P3 P3 ® Nm ® EXPANSION NA ® eCe ® EXPANSION NA ® y � o �ovwi z z m z z m m m E 4100-0621 4100-5101 m 4100-5101 m w ANALOG AUDIO XPS POWER SUPPLY XPS POWER SUPPLY RISER CARD 120VAC 60Hz 120VAC 60Hz �NDO LICF�d' 's CN2AR AR AU% AV% ••••••• -p pA�r ///••. Fa tB nn ,8��i PONFR POMER !.°✓ / 'j' •. d 6 A A 5_6_7_8 13 14 15 16 21 22 23 24t,)�@ w+{ 77 78 79 80_ 85 88 87 88_ 93 94 95 96_ 101 1_ 103 104 109 11_ 111 112 ® + U5{]21 ]4S ) 1 3 f2+{+ 12]433) i ee+ a O o O ' O O O O + O�.`:� 0 - 0 :Q 44967 G; r FROM FACP IN OFFICE TO EXISTING ZONES �'` ••••••3/13 ' � TO FACP IN OFFICE p 9 •. 9/23/13 `� w TO EXISTING ZONES TO EXISTING ZONES FSS�ONAI_ L TO EXISTING ZONES TO EXISTING SPEAKER CKTS - "S1-S6" TO 7TH FLR VISUALS - "V16" 0 m (!v 0 O® 0 25 28 27 28 +33 341135 36 041 421143+44 TB 1 a113 11 115 118 a121 1 1-23 124 128 1 131 132 a137 1 139 140 a146 1 147 148 �L,6 7 8 91, o. B+B-A+A-B+B-A+A-B+B-A+ y n 4100-5005 4100-5005 4100-5005 m m 9 m m m m g m m m m g m m nn 4100-5005 4100-5005 4100-5005 4100-5005 4100-5005 NAC1s NAC17 NACU 0 v CLASOSN B CLASOSN B CLASOSN B rSI m W S3 S` S5 V CLASOSN B CLASOSN B CLASOSN B CLASOSN B CLASOSN B MOTHER BD. MOTHER BD. MOTHER BD. TO EXISTING SPEAKER CKTS - S7-S9' MOTHER BD. MOTHER BD. MOTHER BD. MOTHER BD. MOTHER BD. TO EXISTING SPEAKER CKTS - S10-S12 . 1 A 1 A 1 A 1 A 1 1 A 1 1 A 1 A 1 A n ,[]:I : P2 P2 P2 r 12 P2 P2 P2 P2 + I + + I t l + • J1 • J1 ° J1 NA7C m NAC rn NAC NAC m NAC m NAC 1®, • J1 ° J1 • J1 • J1 • J1 NAC19 W20 1 P2 1 , 1 1 lip, , S SB SB 1 11 312 PZ 1 , 1 , 1 , 1 1 j1pI , d P] P1 P1 P] P1 P1 P1 °m J 4100-1246 J J w P4 100 WATT NA APB EXPA SIGN MODULE am 410XPS115 gal 1 , 566-031) � 1 , I 1 P3 P3 P3 P3 P3 P3 P3 P3 ® sn a EXPANSION NA ° z z z z z z z z z z m d m a 4100-1315 XPS POWER SUPPLY o ANALOG 100 WATT AMPLIFIER 120VAC 60Hz E 70V RMS 120VAC 60Hz s sr9 �oB POYER 29 3D 31 32 37 38 39 40 45 K 47 48 117 11 119 120 125 12 127 128 133 1 175 138 141+14',+143144 149 15( 151 152 ® .N enacuP AU69 _ II LII IW,LWLITF,]LII� +; 1 +4+ 7 1- 11 - 1 +�a ; 1 a,+ 1 7 1- - 7 1 +,a ; r O O O rez - BWY(+)P5 O O O O O 162 ® B111Y(-) P4 NO d O TO EXISTING ZONES TO EXISTING ZONES FERRITE BEAD TO RISER UP BUILDING (FUTURE) N TO BSMT FLR VISUALS - "V1" TO EXISTING ZONES TO NEW SPEAKER CKTS - "S13-S18" TO EXISTING ZONE N C 0 41, 0 lose 0 0 0 49 50 51 52 57 58 59 80 85 88 87 88 - - _ _ _ _ _ _ _ _ _ _ _ 181 1a2 7 I TB1 HNIf H HM HH HN NH m9 m m < < 2 3 4 5 5 / N 4 1011,21.51415. m y m < m m < 4100-5005 4100-5005 4100-5005 m m m m m 9 m m m m m 4100-5005 4100-5005 4100-5005 NACI mNAC26 +„AL,` ui ONM 9� n 8 ZONE 8 ZONE 8 ZONE NAC ^ NAC NAC NAC NAC ^ NAC nn 8 ZONE 8 ZONE 8 ZONE v CLASS B CLASS B CLASS B S13 TO NEW SPEAKER CKTS - "S19-S21” V CLASS B CLASS B CLASS B V MOTHER BD. MOTHER BD. MOTHER BD. TO NEW SPEAKER CKT - "S22" MOTHER BD. MOTHER BD. MOTHER BD. 2 4100-5111 OO `_ A P12 1 , A SYSTEM POWER SUPPLY P2 P2 P2 120VAC 60Hz O O P]° + I + I I + t l + + I NAC NAC 1^ NAC NAC NAC NAC ,[� �•)'•Ipz 1 , J1 lip, 1 J1 lip, ,JI 519 520 521 S22 S23 S24 °m.pp 1 J1 , JI 1 J1 P1 J 4100-1248 �S] P1 P1 J P1 J: Q Q VIII O C 100 WATT NAC II� s LS EXPA SIGN MODULE N O 91 VP3 [NP3 566-031) a , 1 FP3 O 1..1� `�� C� J PS � P3 13 � E 2 Z 2 Z Z 2 Z Z Z POA"ME11R AVlO OV+24 NO C NC B16Nj+P{ Q r 1'' 0 � Q V d 4100-1315 B'"'Y••t-PS v ai ANALOG 100 WATT AMPLIFIER • aTM OO OO ® O Q 70V RMS 120VAC 60Hz O O Q d ® TO RISER UP BLDG (FUTURE) J J N T 53 54 55 56 81 82 63 64 89 70 71 72 c BACKUP AUDIO H O C E` O O O M - My(+)P5 O sees sees O Goes sees=(I 998)O E ® BAY`-' °` ® CONNECT TO e,CONNECT TO H o 120VAC 60HZ — — — — 120VAC 60HZ Ll_I MOUNTS TO BACKBOX MOUNTS TO BACKBOX .c TO EXISTING ZONES o s ~ o 0 0 0 5 0 0 0 0 J Z 0 0 0 0 & Z 0 0 0 0 o 11E Z O O o 0 0 0 0 0 0 0 0 0 � < O O O O ¢ O O O O - 0 m a a a a I a a a a I y rn CD 0. LIJ J J E m m Q rn o c — U) Z m 0 ° E J C U o Cn - LLI E > 0 o m `c E Y c O Nn ® ® U � E U o 15 a" C7 ® ® W $ E Q c �p co ® ® U 0 E IS v J m W Y c Z co N Q 3 E 0 N C D Dppi� TD D N 2 .^o c C) IRE ALARV RANSPONDER FUSE ° o CABINET2 IN � m Lu GARAGE RED Z SCALE: NTS DRAWN BY: NSW s O CHECKED BY: SS U) - + - + ® ® ISSUE DATE: 9/19/13 t J BLACK JOB#: ® ® PROJECT#: 419:972539701 CC o t FIRE ALARM TRANSPONDER SIMPLEXGRINNELL© 2013 CABINET #1 SYSTEM: ` t w � GARAGE 110 Ah BATTERY SET 2081-9279 FIRE ALARM SYSTEM c `° SCALE: NTS ,= rn SHEET: N v z N N L_ 3 TRANSPONDER PANEL 0 3 DETAIL a U U CO y CO , Lb C Q7 N_ U a 0 O Q DRAWING NOTES: w 2081 —9280 CABINET W/2081 —9279 110Ah BATTERIES ACCESS PANEL LOCATED THE INFORMATION&SYMBOLS SHOWN IN BOLD LINETYPE ARE NEW. I[ /�/`1'5O2 Co m ON SIDE OF CABINET F x SCALE: NTS THE INFORMATION & SYMBOLS SHOWN IN LIGHT LINETYPE ARE EXISTING. d' T N d w — v= a MAPNET CHANNEL M1 SWITCH SETTINGS IDNET CHANNEL M2 SWITCH SETTINGS MAPNET CHANNEL M3 SWITCH SETTINGS Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 LODGE TOWER 4100ES UPGRADE 4100u FACP GLNIAV WAILIF 11-1 GROUND rLH GAIRAGL uVAILK LOW x x x x x x x x ON x x x x x x x x ON LivIAM _AI M3 !1TH GARAGE STur-AGE CLuJL_T 535 Y Total Alarm Total MIKE -1 1ST FLR W RESIDENTIAL CORRIDOR x x x x x x x x °N Standby -2 GENIAM SO M1-2 GROUND FLR GARAGE SPRINKLER TAMPER x x x x x x x x °N VSMOKE 2 1ST FLR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON d' 7�FNIAM HEAT M3 - _uUTH GARAGE STORAGE CLOSET #534 x x x x x x x x °N Module Oty Description Current Standby Current Alarm C:>LO t ,:1-3 GENIAM SO M1-3 GRND FLR ENTRANCE/CONCIERGE TAMPER x x x x x x x x °N - --�._,�r) VSMOKE -3 'IST FLR MID W RESIDENTIAL CORRIDOR x x oN M3-3 ,_ENIAM HEAT M3 3 SOUTH GARAGE STORAGE CLOSET #533 x x x x x x x x °N 00 0 x x x x X x Panel Equipm Equipment L M1-4 GENIAM SO M1-4 GRND FLR ELEV 3 EQUIP ROOM TAMPER x X x X X x x x ON M" ,l PHOTO VSMOKE 1ST FLR MID RESIDENTIAL CORRIDOR X X x X x x X X ON M3-4 GENIAM HEAT M3-4 SOUTH GARAGE STORAGE CLOSET #532 x X x x X x x x ON C?C? M1_5 GENIAM GENIAM SO M1-5 GRND FLR ELEV PIT TAMPER x x ON x x °N M3-5 �CENIAM HEAT M3-5 SOUTH GARAGE STORAGE CLOSET 531 x x ON 4i�-!r;-i v_,'� MASTER CONTROLLER POWER '�,iiPLY v.Ij�;uu O.rluu0 O.0 iu�._, ��;o�� Mco S2 X X X x X X M- PHOTO VSMOKE IST FLR MID ELEVATOR LOBBY x x x x x x # X x x x x x MM m M1-6 GENIAM SO M1-6 1ST FLR SPRINKLER CONTROL VALVE x x ON x x ON M3- GENIAM HEAT M3-6 SOUTH GARAGE STORAGE CLOSET 530 x x oN 4100-01 10 MAPNET II ADDRESSABLE MODULE 0.2700 0.5400 0.2900 0.5800 x x x x x x M,' PHOTO VSMOKE -b 1ST FLR MID RESIDENTIAL CORRIDOR x x x x x x # x x x x x x M1-7 GENIAM WATER M1-7 1ST FLR SPRINKLER WATERFLOW SWITCH x x x oN c x x x ON M3- ENIAM HEAT M3-7 SOUTH GARAGE STORAGE CLOSET 529 x x x ON 4100-3107 1 IDNET+ MODULE, UP TO 250 POINTS 0.0750 0.0750 0.1150 0.1150 w _y X X x X X M[ PHOTO VSMOKE 7 1ST FLR EAST RESIDENTIAL CORRIDOR x x x x x # x x x x x Z M1-8 GENIAM UTILITY M1-8 1ST FLR WEST STAIR LOW TEMP SENSOR x ON X ON M3 JENIAM HEAT M3-8 SOUTH GARAGE STORAGE CLOSET W x ON A� O i5 x x x x x x x PHOTO VSMOKE -8 IST FLR E ELEVATOR LOBBY x x x X, X x x x x x x x x 4100-432' 6 CIRCUIT CLASS B (STYLE Y) 0.0250 0.0750 0.0700 0.2100 c M1-9 GENIAM UTILITY M1-9 1ST FLR EAST STAIR LOW TEMP SENSOR x X x x x x x x °N ADRPUL °l�l -9 1ST FLR WEST x x ON M3 GENIAM HEAT M3-9 SOUTH GARAGE STORAGE CLOSET #527 x x x x x x x x °N ?4 POINT 0 INTERFACE MODULE n D n�p,� X X x x x x 4 00-740' - / ° 0.0780 0.0780 n x M1-10 GENIAM SO M1-10 2ND FLR SPRINKLER CONTROL VALVE x x x x x x x x ON PHOTO -10 2ND FLR W RESIDENTIAL CORRIDOR x x ON M3-10 IENIAM HEAT M3-10 SOUTH GARAGE STORAGE CLOSET #528 x x x x x x x x °N O 0 x x x x x x 4100-5125 1 REMOTE POWER SUPPLY W/CHARGER - 120VAC 0.1500 0.1500 0.1850 0.1850 U M1_11 GENIAM WATER MI-11 2ND FLR SPRINKLER WATERFLOW SWITCH x x x x x x x x ON 42 PHOTO VSwlu;, E -11 2ND FLR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON M3-11 GENIAM HEAT M3-11 SOUTH GARAGE STORAGE CLOSET #526 x x x x x x x x °N 4100-9620 1 BASIC AUDIO WITH MICROPHONE - ANALOG 0.2250 0.2250 0.2250 0.2250 �� U) M1-12 GENIAM SO M1-12 3RD FLR SPRINKLER CONTROL VALVE x xxx x x x x °N M2-12 PHOTO VSMOKE 12 2ND FLR MID W RESIDENTIAL CORRIDOR x xxx x x x x ON M3-12 GENIAM HEAT M3-12 SOUTH GARAGE STORAGE CLOSET #525 x xxx x x x x ON 0� C:) m MI-13 GENIAM WATER M1-13 3RD FLR SPRINKLER WATERFLOW SWITCH x x x x x x x x ION - � F x x x ON M3-13 GENIAM HEAT M3-13 SOUTH GARAGE STORAGE CLST CORR CTR x x x ON 4100-6052 1 EVENT REPORTING DACT 0.0300 0.0300 0.0400 0.0400 - PHOTO VS -13 2ND FLR MID RESIDENTIAL CORRIDOR x x x x x x x x x x coo ° M1-14 GENIAM SO M1-14 4TH FLR SPRINKLER CONTROL VAVLE x x x ON x x x oN M3-14 GENIAM HEAT M3-14 SOUTH GARAGE STORAGE CLOSET ?1 x x x ON 4100-6038 1 DUAL RS-232 IF CARD 0.1320 0.1320 0.1320 0.1320 p�,ir, x x x x x PHOTO _ -14 2ND FLR MID ELEVATOR LOBBY X x x x x #c- x x x x x L m M1-15 GENIAM WATER M1-15 4TH FLR SPRINKLER WATERFLOW SWITCH X X X X ON c X x x x ON M3-15 GENIAM HEAT M3-15 SOUTH GARAGE STORAGE CLOSET 522 x X X X ON 4100-1326 1 DIGITAL FLEX 50W AMP W/3 NACS - 25V 0.0850 0.0850 2.2700 2.2700 �_ 000 c? x x x x PHOTO VSM_ 1� 2ND FLR MID RESIDENTIAL CORRIDOR x x x x # x x x x � ch M1-16 GENIAM SO M1-16 5TH FLR SPRRNKLER CONTROL VALVE x x x x x x x x °N PHOTO VSMU:<L 1 16 2ND FLR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON M3-16 GENIAM HEAT M3-16 SOUTH GARAGE STORAGE CLOSET #524 x x x x x x x x °N 4100-1294 1 LED/SWITCH SLIDE-IN LABEL KIT 0.0000 0.0000 0.0000 0.0000 C� ��`,' s M1-17 GENIAM WATER M1-17 5TH FLR SPRINKLER WATERFLOW SWITCH x x x x x x x x ON V2-17 PHOTO VSMOKE M2-17 2ND FLR E ELEVATOR LOBBY x x ON M3-17 GENIAM HEAT M3-17 SOUTH GARAGE STORAGE CLOSET #523 x x x x x x x x °N �EDcw.> y x x x x x x 4100-6079 1 BAFFLING INTERNET INTRFACE 0.1450 0.1450 0.1450 0.1450 U w_ - MI-18 GENIAM SO M1-18 6TH FLR SPRINKLER CONTROL VALVE x x x x x x x x ON V12-I` ADRPUL PULL M2-18 2ND FLR WEST x x x x x x x x ON M3-18 GENIAM HEAT M3-18 SOUTH LARGE STORAGE CLST CORR CTR x x x x x x x x °N N w °z> 4100-7153 1 INFOALARM 41000 UPGRADE 0.0820 0.0820 0.1270 0.1270 v� v M1-19 GENIAM WATER M1-19 6TH FLR SPRINKLER WATERFLOW SWITCH x x x ON x x x °N M3-19 GENIAM HEAT M3-19 SOUTH GARAGE STORAGE CLOSET 519 x x x ON 04 (0 o x x x x x M;' SPARE x x x x x # x x x x x 4100-1293 1 PANEL MOUNTED PRINTER 0.1250 0.1250 0.8000 0.8000 (� �o� x x ON x x ON M3-20 GENIAM HEAT M3-20 SOUTH GARAGE STORAGE CLOSET #520 x x x x x x x x °N 64 64 LED SWITCH CONTROLLER M1-20 GENIAM SO M1-20 7TH FLR SPRINKLER CONTROL VALVE x x x x x x M2 PHOTO VSMOKE M2-20 3RD FLR W RESIDENTIAL CORRIDOR x x x x x x M1-21 GENIAM WATER M1-21 7TH FLR SPRINKLER WATERFLOW SWITCH x x x x x x x x ON M PHOTO VSMOKE M2-21 3RD FLR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON M3-21 GENIAM HEAT M3-21 SOUTH GARAGE STORAGE CLOSET #518 x x x x x x x x ON 4100-1288 1 / / 0.0200 0.0200 0.0200 0.0200 w M1-22 GENIAM UTILITY M1-22 7TH FLR WEST STAIR LOW TEMP SENSOR x x x X x x x x °N ME PHOTO VSMOKE M2-22 3RD FLR MID W RESIDENTIAL CORRIDOR x x x x x x X X ON M3-22 GENIAM HEAT M3-22 SOUTH GARAGE STORAGE CLOSET #517 x x x x x x x x ON 4100-1280 2 8 SWITCH, 8 RED LED MODULE 0.0000 0.0000 0.0240 0.0480 y M1-23 GENIAM UTILITY M1-23 7TH FLR EAST STAIR LOW TEMP SENSOR x x x x x x x x ON M2 PHOTO VSMOKE M2-23 3RD FLR MID RESIDENTIAL CORRIDOR x x x x x x x x ON M3-23 GENIAM HEAT M3-23 SOUTH GARAGE STORAGE CLST CORR CTR x X x x x x x x °N 4100-1252 1 1 CHANNEL AUDIO OPERATOR INTERFACE 0.0000 0.0000 0.0240 0.0240 NDQ L/� M1-24 GENIAM UTILITY M1-24 7TH FLR ELEV MACH RM CONTROL VALVE X X ON x x ON M3-?4 GENIAM HEAT M3-24 SOUTH GARAGE STORAGE CLOSET 516 x x ON OQ'•..•••.. x x x x x x M2-2=- PHOTO VSMOKE M2-24 3RD FLR MID ELEVATOR LOBBY x x x x x x - # x x x x x x 4100-1241 1 MESSAGE EXPANSION BOARD - 8 MINUTES 0.0020 0.0020 0.0170 0.0170 • M1-25 GENIAM SO M1-25 BSMT ELEV 1 MACHINE RM CNTRL VLVE x x x ON x x x ON M3-25 GENIAM HEAT M3-25 SOUTH GARAGE STORAGE CLOSET 515 x x x ON 0•�pAV! Fa # x x x x x M2-25 PHOTO VSMOKE M2-25 3RD FLR MID RESIDENTIAL CORRIDOR x x x x x # x x x x x 4100-9600 1 REMOTE ANNUNCIATORS & MINIPLEX TRANSPONDERS * RUI CURRENT DRAWS INCLUDED BELOW • qtr (\p,) • M1-26 GENIAM SO M1-26 BSMT BACKFLOW PREVENTER CNTRL ONE x x x x x x x x ON M?-2( PHOTO VSMOKE M2-26 3RD FLR EAST RESIDENTIAL CORRIDOR x x x ON M3-26 GENIAM HEAT M3-26 SOUTH GARAGE STORAGE CLST CORR CTR x x x x x x x x ON ` 3 x x x x x Panel Totals 1.7640 5.0160 M1-27 REAM RELAY M1-27 ELEVATOR 1 SHUNT TRIP X X X X ON X X x x ON M3-27 GENIAM HEAT M3-27 SOUTH GARAGE STORAGE CLST CORR E x X x X ON 'Q 44967 �• r # x x x x G PHOTO VSMOKE M2-27 3RD FLR E ELEVATOR LOBBY x x x x x x x x IDNet Addressable Devices SLC .� >c. M1-28 RZAM RELAY M1-28 ELEVATOR #2 SHUNT TRIP x x x x x x x x ON Mn ADRPUL PULL M2-28 3RD FLR WEST x x x x x x x x ON M3-28 GENIAM HEAT M3-28 SOUTH GARAGE STORAGE CLOSET #514 x x x x x x x x °N p.� �: o M1-29 GENIAM SO M1-29 ELEVATOR #3 POWER MONITOR X x x X X x x x ON M2-el_ x x x x ON M3-2I) GENIAM HEAT M3-29 SOUTH GARAGE STORAGE CLOSET 513 X x x x ON 4 - -COG IDNET SINGLE ACTION PULL STATION 0.00(; 0.0000 0.0000 0.0000 •� 9/23/13 �c, x x x x ON SPARE x x x x G # x x x x x x x ON 4090-9001 29 IDNET SUPERVISED IAM 0.0000 0.0000 0.0000 0.0000 �'�F�'••.....••'••\�� a M1-30 PHOTO VSMOKE M1-30 ATTIC ELEVATOR MACHINE ROOM X x X X M2-:,0 PHOTO VSMOKE M2-30 4TH FLR W RESIDENTIAL CORRIDOR x x x x x x X x ON M3-��(-! GENIAM HEAT M3-30 SOUTH GARAGE STORAGE CLOSET #512 x X X X M1-31 GENIAM SO M1-31 ATTIC ELEV LOS SPRINK CONTROL VLVE x X x x x x x x ON M2-31 PHOTO VSMOKE M2-31 4TH FLR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON M3-3I GENIAM HEAT M3-31 SOUTH GARAGE STORAGE CLOSET #511 x x x x x x x x ON 4090-9116 4 INTELLIGENT IDNET ISOLATOR MODULE 0.0000 0.0000 0.0000 0.0000 Ss��NALE o M1-32 HEAT HEAT M1-32 ELEVATOR #1 TOP OF SHAFT x X x X X x X X ON M2-32 PHOTO VSMOKE M2-32 4TH FLR MID W RESIDENTIAL CORRIDOR X X X X X x X x ON M3-32 GENIAM HEAT M3-32 SOUTH GARAGE STORAGE CLST CORR E x X X X x x x X ON 4098-97'14 61 TRUEALARM PHOTO SMOKE SENSOR 0.0000 0.0000 0.0000 0 M1-33 GENIAM SO M1-33 GARAGE WEST LOW TEMPERATURE SENSOR x X x X X x X X ON M2-33 PHOTO VSMOKE M2-33 4TH FLR MID RESIDENTIAL CORRIDOR x x x x x x x X ON M3-T GENIAM HEAT M3-33 SOUTH GARAGE STORAGE CLOSET #59 x X x x x x X X ON 4009-920` 4009 IDNET NAG EXTENDER, 120 VAC 0.0000 0.0000 0.0000 1).0000 m M1-34 HEAT HEAT M1-34 BSMT ELEVATOR #1 MACHINE ROOM X x x X X x X X ON M2-34 PHOTO VSMOKE M2-34 4TH FLR MID ELEVATOR LOBBY x x x x x x x x ON M3-3 GENIAM HEAT M3-34 SOUTH GARAGE STORAGE CLOSET #510 x x x x X x x X °N 4098-9792 6 TRUEALARM SENSOR BASE 0.0000 0.0000 0.0000 0.0000 M1-35 HEAT HEAT M1-35 ELEVATOR , MACHINE ROOM x X x ON c X X X ON M3-35 GENIAM HEAT M3-35 SOUTH GARAGE STORAGE CLOSET 58 x X x ON # x x x x x M2-35 PHOTO VSMOKE M2-3. 4TH FLR MID RESIDENTIAL CORRIDOR x x x X x # x x x x x 4098-9794 5 TRUEALARM SENSOR SOUNDER BASE 0.0000 0.0000 0.0000 0.0000 ff M1-36 HEAT HEAT M1-36 ELEVATOR #2 TOP OF SHAFT X x x x x x x x ON M2-36 PHOTO VSMOKE M2-36 4TH FLR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON M3-36 GENIAM HEAT M3-36 SOUTH GARAGE STORAGE CLOSET #57 x x x x x x x x ON M1-37 RZAM RELAY M1-37 ELEVATOR 2 TOP OF SHAFT DAMPER x x x ON M3-37 GENIAM HEAT M3-37 SOUTH GARAGE STORAGE CLOSET 56 Ma net Addressable Devices SLC X X X ON # x X x X X x X X °N # x x x x x M2-37 PHOTO VSMOKE M2- 7 4TH FLR E ELEVATOR LOBBY x x x x x 2190-9163 13 MAPNET UNSUPERVISED CONTROL ZAM 0.0000 0.0000 0.0000 O.Lu - 0 M1-38 PHOTO VSMOKE M1-38 7TH FLR ELEVATOR LOBBY x x x x x x x x ON M2-38 ADRPUL PULL M2-38 4TH FLR WEST x x x x x x x x ON M3-38 GENIAM HEAT M3-38 SOUTH GARAGE STORAGE CLST CORR E x x x x x x x x ON X X X x ON x x x x ON M3-39 SPARE x X x X X x X X ON 2190-9172 83 MAPNET SUPERVISED IAM 0.0000 0.0000 0.0000 0.0000 M1-39 GENIAM WATER M1-39 BSMT SPRNKLR ANTIFREEZE FLOW SWTCH X X X X M2-39 SPARE x x x x 2099-9795 10 MAPNET SINGLE ACTION PULL STATION 0.0000 0.0000 0.0000 0.0000 0. M1-40 GENIAM SO M1-40 BSMT SPRINKLER CONTROL VAVLE x x x x x x x x ON M2-40 PHOTO VSMOKE M2-40 5TH FLR W RESIDENTIAL CORRIDOR x x x x x x x x ON THROUGH M1-41 GENIAM WATER M1-41 TRASH CHUTE SPRINKLER FLOW SWITCHE x X x x x x x x °N M2-41 PHOTO VSMOKE M2-41 5TH FLR MID W RESIDENTIAL CORRIDOR x X X x X x x x ON M3-127 SPARE x X x x x x x x ON 4098-9714 40 TRUEALARM PHOTO SMOKE SENSOR 0.0000 0.0000 0.0000 0.0000 a M1-42 GENIAM SO M1-42 TRASH CHUTE SPRINKLER CONTROL VLVE X x x x x x X X ON PHOTO VSMOKE M2-42 5TH FLR MID W RESIDENTIAL CORRIDOR x x x x x x x x ON 4098-9733 3 TRUEALARM HEAT SENSOF' 0.0000 0.0000 O.000J' 0.0 m 0 M1-43 GENIAM WATER M1-43 BSMT MAIN SPRINKLER FLOW SWITCH x x x x x x x x ON --- °HOTO VSMOKE M2-43 5TH FLR MID RESIDENTIAL CORRIDOR x x x x x x x x ON 4098-9756 1 TRUEALARM DUCT SMOKE R❑_ ! nL-P 0.0000 0.0000 0.0000 0.0( : M1-44 RZAM RELAY M1-44 ELEVATOR #1 TOP OF SHAFT DAMPER x x x x x x x x ON M2 'LOTO VSMOKE M2-44 5TH FLR MID ELEVATOR LOBBY x x x ON 4098-9792 53 EALARM SENSOR O.000C 0 0.0000 w X X X X X SCI i � �u"i MI-45 GENIAM SO MI-45 ATTIC SPRINKLER VALVE x x x x x x x x ON M2 0T0 VSMOKE M2-45 5TH FLR MID RESIDENTIAL CORRIDOR x x x x x x x x ON Miscellaneous Peripheral Devices That May Require System Power o M1-46 GENIAM WATER M1-46 ATTIC SPRINKLER FLOW SWITCH x X x X x x x x ON M2-46 PHOTO VSMOKE M2-46 5TH FLR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON 4098-9843 FLAY PA.- D 0.0000 0.0150 H M1-47 GENIAM SO M1-47 GROUND FLR LAUNDRY CHUTE VALVE X X X X x x x x ON M2-47 PHOTO VSMOKE M2-47 5TH FLR E ELEVATOR LOBBY X x x x x x x x ON 4098-9756 SMOKE SENSOR WE RELAY OUTPUT 0.0030 0.0150 2 M1-48 GENIAM SO M1-48 BSMT BACKFLOW PREVENTER CNTRL TWO x x x x x x x x °N M2-48 ADRPUL PULL M2-48 5TH FLR WEST x x x x x x x x °N a M1-49 GENIAM PULL M1-49 GRND FLR NW EXIT WP PULL x x x xxx x xi M2-49 SPARE x x x xxx x x °N LODGE TOWER NAC PANEL 1 EXISTING 4009 NAC SOUNDER BASE O.000U 0.0200 0.1000 X x X ON BASE 0.0000 0.000_ 0 0`_YI s MI-50 GENIAM PULL MI-50 GROUND FLR LOADING 015 x x x x x M2-50 PHOTO VSMOKE M2-50 6TH FLR W RESIDENTIAL CORRIDOR x x x x x x X x ON Standby Total Alarm Total 16 M1-51 ADRPUL PULL M1-51 1ST FLR WEST x x x x x x x x ON M2-51 PHOTO VSMOKE M2-51 6TH FLR MID W RESIDENTIAL CORRIDOR x x x x ON 0t Descri tion Standb ! UN'-- -C =CNTROL ZAM 0.0100 1 0.040,_ x x x x Module Y P Current Y Current Alarm M1-5 ADRPIJL PULL M1-52 2ND FLR WEST x x x ON x x x ON Notification Appliances :N x x x x x M2-52 PHOTO VSMOKE M2-52 6TH FLR MID W RESIDENTIAL CORRIDOR x x x x x Panel Equipment IE M1-53 ADRPIJL PULL M 1-53 3RD FLR WEST x X x x x x X X °N M2-53 PHOTO VSMOKE M2-53 6TH FLR MID RESIDENTIAL CORRIDOR x x x x x x x x ON MTWP'-24 71,W- R MI_!1 _)NE, BELL SETTING BEG 0.0000 0.0000 U M1-54 ADRPUL PULL M1-54 4TH FLR WEST x x x x x x x x ON M2-54 PHOTO VSMOKE M2-54 6TH FLR MID ELEVATOR LOBBY x x x x x x x x ON 109-9201 4009 IDNET NAC EXTENDER, 1 VAC 0.0850 0.1850 u.l�u0 Peripheral Totals 0.1330 0.7030 x x x x x ON AC CAFL =PT, IDNET RUI Totals 1 0.0035 0.0035 6 M1-55 ADRPUL PULL M1-55 5TH FLR WEST x x x x x xxx ON M2-55 PHOTO VSMOKE M2-55 6TH FLR MID RESIDENTIAL CORRIDOR x X x M1-56 ADRPUL PULL M1-56 6TH FLR WEST x x x x x x x x ON M2-5G PHOTO VSMOKE M2-56 6TH FLR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON Panel Totals 0.1250 0.2250 Address Totals 310.5 Addresses 0.2761 0.2833 M1-57 ADRPIJL PULL M1-57 7TH FLR WEST x x x x x x x x ON M2-57 PHOTO VSMOKE M2-57 6TH FLR E ELEVATOR LOBBY x x x x x x x x ON Miscellaneous Peripheral Devices That May Require System Power * Current draw included under "Device Addresses Used" (See "Additional Current Draws:") Total Standby 2,1766 Total Alarm 6.0058 H M1-58 PHOTO VSMOKE M1-58 BSMT STAIR LOBBY x x x x x x x x ON M2-58 ADRPUL PULL M2-58 6TH FLR WEST x x x x x x x x ON Notification Appliances 1. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit. M1-59 PHOTO VSMOKE M1-59 ELEVATOR #3 TOP OF SHAFT x X x x x x x x ON M2-59 SPARE x x x x x x x x ON 4906-9101 2 V/O MC NON-ADDRESS, 1 15 0.0000 0.0000 0.0600 0.1200 2• Backup Amplifier assumes Main Amplifier alarm current on failure. M1-60 PHOTO VSMOKE M1-60 ELEVATOR #3 MACHINE ROOM 016 x x x x x x x x ON M2-60 PHOTO VSMOKE M2-60 7TH FLR W RESIDENTIAL CORRIDOR x x x x ON Standby Standby Alarm Alarm y x x x x 4906-9101 1 V/0 MC NON-ADDRESS, RED, WALL 30 0.0000 0.0000 0.0940 0.0940 M1-61 PHOTO VSMOKE M1-61 GRND FLR ELEV #3 LOBBY x x x x x x x x ON M2-61 PHOTO VSMOKE M2-61 7TH FLR MID W RESIDENTIAL CORRIDOR x x x x x ON Battery Set 1 (Cabinet/Charger 1 Current Total Current Total x x x 4906-9153 13 S/V M-C NON-ADDRESS, WHT, WALL 15 0.0000 0.0000 0.0600 0.7800 t MI-62 PHOTO VSMOKE MI-62 1ST FLR ELEV 3 LOBBY x x x x x ON x x x x x ON Select ALL Power Supplies on this battery set: # x x x M2-62 PHOTO VSMOKE M2-62 7TH FLR MID W RESIDENTIAL CORRIDOR x x x d 4906-9153 2 S/V M-C NON-ADDRESS, WHT, WALL 30 0.0000 0.0000 0.0940 0.1880 =_ M1-E3 PHOTO VSMOKE M1-63 2ND FLR ELEV #3 LOBBY x x x x x x x x ON M2-63 ='HOTO VSMOKE M2-63 7TH FLR MID RESIDENTIAL CORRIDOR x x x x x x x x'ON XPS-1 1.8970 3.4490 � x ON 4906-9153 13 S/V M-C NON-ADDRESS, WHT, WALL 75 0.0000 0.0000 0.1860 2.4180 Am p-1 M1-64 PHOTO VSMOKE M1-64 3RD FLR ELEV #3 LOBBY X X x X X x X M2-64 =HOTO VSMOKE M2-64 7TH FLR MID ELEVATOR LOBBY X X X X x x x x ON P- 0.0850 2.2700 ti Total Standby 0.1250 Total Alarm 3.82.5 ° M1-65 PHOTO VSMOKE M1-65 4TH FLR ELEV #3 LOBBY x X x x x x x x ON M2-65 PHOTO VSMOKE M2-65 7TH FLR MID RESIDENTIAL CORRIDOR x x x x x x x x ON Sub Total 1.9820 5.7190 M1-66 PHOTO VSMOKE M1-66 5TH FLR ELEV #3 LOBBY x x x x x x x x ON M2-66 PHOTO VSMOKE M2-66 7TH FLR EAST RESIDENTIAL CORRIDOR x x x x x x x x ON Additional Current Draws: MI-67 PHOTO VSMOKE MI-67 6TH FLR ELEV 3 LOBBY x x x ON S x x x x x x x x °N RUI Connected Peripheral Devices 1 x 0.0035 = 0.0035 x 0.0035 = 0.0035 O 0 # x x x x x M2-67 PARE Standby Standby MI-68 PHOTO VSMOKE M 1-68 7TH FLR ELEV 3 LOBBY x x ON X x x x x x x x ON Y Y Alarm Alarm MAPNET/IDNet Device Addresses ordered used 311 x 0.000889 = 0.2761 x 0.000912 = 0.2833 0 # X X X X x X M2-G8 ADRPUL PULL M2-68 7TH FLR WEST x x x ON Battery Set #1 Cabinet/Charger 1 Current Total Current Total m M1-69 HEAT HEAT M1-69 ELEVATOR #3 MACHINE ROOM FOR SHUNT X X X X X M2-69 SPARE x X x X x x x x ON Sub Total 2.2616 6.0058 0 x x x ON 4009 0.1250 3.8250 Uj Q Of o M1-70 HEAT HEAT M1-70 ELEVATOR #3 PIT x x x x x x x x °N M2-70 ADRPUL PULL M2-70 IST FLR EAST x x x x x p P P Y 20% 63 x 0.000889 = 0.0560 x 0.000912 = 0.0575 # x x x x M2-71 ADRPUL FULL M2-71 2ND FLR EAST Total 0.1250 3.8250 S are addressable oint ca acit Q M1-71 HEAT HEAT M1-71 ELEVATOR 3 TOP OF SHAFT x x x x ON X x x xxxxx °N W 0 ° M1-72 REAM RELAY M1-72 ELEVATOR 3 PRIMARY RECALL x x ON x x ON Total 2.3176 6.0633 O # x x x x x x M2 i2 ADRPUL PULL M2-72 3RD FLR EAST x x x x x x Standby ime = Standby Ah r � 0 W Y 24 Hrs x 0.1250 = 3.0000 Y V J o M1-73 REAM RELAY M1-73 ELEVATOR #3 ALTERNATE RECALL x x x x x x x x ON M2-73 ADRPIJL FULL M2-73 4TH FLR EAST x x x x x x x x ON v J_ E M1-74 REAM RELAY M1-74 ELEVATOR #3 SHUNT TRIP x x x x x x x x ON M2-74 ADRPIJL PULL M2-74 5TH FLR EAST x x x x x x x x ON Alarm Time = 15 Min 0.25 x 3.825 = 0.9563 Alarm Ah Standby ime = Standby Ah w 0 MI-75 RZAM RELAY MI-75 ELEVATOR 3 CAB LIGHT x x x x ON Y 24 Hrs x 2.3176 = 55.6229 Y # x x x x M2-75 ADRPUL PULL M2-75 6TH FLR EAST x x x x ON 3.9563 Alarm Time = 15 Min 0.25 x 6.0633 = 1.5158 Alarm Ah C) Q U x x x x Additional Spare Capacity = 20% + 0.7913 O x x x ON 57.1387 J M1-76 HEAT HEAT M1-76 GRND FLR LOADING 015 x x x x x M2-76 ADRPIJL PULL M2-76 7TH FLR EAST x x x ON 0 x x x x x 4.7475 Additional Spare Capacity = 20% + 11.4277 O M1-77 PHOTO VSMOKE M1-77 GRND FLR ELECTRICAL ROOM 018 x x x x x x x x ON M2-77 SPARE x x x x x x x x ON Battery Discharge Factor = 20% + 0.9495 68.5664 OO Q M1-78 PHOTO VSMOKE M1-78 GRND FLR VALET 021 x x x x x x x x ON M2-78 SPARE x x x x oN ry q 2081-9272 6.2AH (2x) 5.6970 Battery Discharge Factor = 20% + 13.7133 = � x x x x Minimum Battery Required J N > a M1-79 PHOTO VSMOKE M1-79 GRND FLR SPRINKLER ROOM 019 x x x x x x x x ON M2-79 NACSPT SIGNAL M2-81 GARAGE NAC PANEL 1 x x x x x ON = ° # x x x Ba ry '"!�I-1 i 7081 7274 '.OAII (2x) Minimum Battery Required 2081-9279 110AH (2x) 82.2797 M1-80 RZAM RELAY M1-80 DOOR HOLDERS x x x x x x x x ON M2-8O HEAT M2-80 GARAGE x x x x x x x x °N Battery Supplied 2081-9296 50AH (4) H e T M'1-81 PHOTO VSMOKE M1-81 GRND FLR MAIN LOBBY x x x x x x x x °N M2- IAM HEAT M2-81 GARAGE x x x x x x x x °N MI-82 PHOTO VSMOKE M1-82 GRND FLR OFFICE 004 x x x x x x x x ON M2-82 AM HEAT M2-82 GARAGE x x x x x x x x ON w M1-83 PHOTO VSMOKE M1-83 GRND FLR MAIN LOBBY x x x x x x x x ON IAM HEAT M2-83 GARAGE x x x x x x x x oN 3 a M1-84 PHOTO VSMOKE M1-84 GRND FLR OFFICE 005 x x x x x x x x °N AM HEAT M2-84 GARAGE x x x ON o 0 x x x x x LODGE TOWER 4100ES UPGRADE 4100u FACP Speaker Db Loss Calculations L M1-85 HEAT HEAT M1-85 GRND FLR FOOD PREP 006 x x x x x x x x ON M2 AM HEAT M2-85 GARAGE x x x x x x x X ON *Circuit Voltage = 25vrms [Et] MAXIMUM -3 dB DROP M1-86 PHOTO VSMOKE M1-86 GRND FLR LOUNGE 007 x x x x x x x x ON M2-86 AM HEAT M2-86 GARAGE X X x X ON N x x x x Total Wire Est. Ckt.Wire Res. Circuit Speaker Speaker Voltage Watts Actual Max Allowable z. z M1-87 HEAT HEAT M1-87 GRND FLR LOUNGE 007 x x x x x x x x ON M2-87 IAM HEAT M2-87 GARAGE x x x x x x x x ON Plan Speaker Speaker Speaker Speaker Watts Gauge Length Per Foot Resistance Current Resistance At End At End dB Loss Ckt. Length or o m MI-88 RZAM RELAY MI-88 WEST ELEV LOBBY DAMPERS x x x x x x x x ON M2-88 IAM HEAT M2-88 GARAGE x x x x x x x x ON SPEAKER CIRCUIT DESCRIPTION Circuit Tap Tap Tap Tap [P] [D] in [Rw] [RI=2D*Rw] [I=P/Et] [Rs=Et/1] [Es=(Et*Rs) [Pe=(Es)[dB=Log10 [ML=(0.414*Rs) N o p M1-89 PHOTO VSMOKE M1-89 GRND FLR HALLWAY 023 x x x x x x x x ON M2-89 IAM HEAT M2-89 GARAGE x x x x x x x x ON Am Number .25 Watt .5 Watt 1. Watt 2. Watt Feet Rs+RI *2 Rs] Pe P *10 2*Rw M1-90 HEAT HEAT M1-90 GRND FLR BATHROOM 008 x x x x ON x x x x x x x x ON SPARE Amp-1 Sl uoic O.ouu U.u00 J: 0 Ft. x x x x M 90 AM HEAT M2-90 GARAGE SPARE Amp-1 S2 0.0078 0.000 0.000 0 Ft. m o M1-91 HEAT HEAT M1-91 GRND FLR BATHROOM 009 x x x x x x x x ON M2 91 AM HEAT M2-91 GARAGE x x x x x x x x oN SPARK Amp-1 S3 18ga 0.0078 0.000 O.000i 0 0.000 0 Ft. ° E cn M1-92 PHOTO VSMOKE M1-92 GRND FLR CONFERENCE ROOM x x x x x x x x ON M2-92 AM HEAT M2-92 GARAGE x x x x x x x x ON U M1-93 PHOTO VSMOKE M1-93 GRND FLR OFFICE 013 x x x x x x x x ON M2-93 AM HEAT M2-93 GARAGE x x x x x x x x ON M1-94 PHOTO VSMOKE M1-94 GRND FLR HALLWAY 023 x x x x x ON x x x x x ON LODGE TOWER 4100ES UPGRADE 4100u FACP VOLTAGE DROPS PID MTWP-2475W-FR MTWP-2475W-FR MTWP-2475W-FR 4009-9201 4009-9201 U =s x X X M2-94 IAM HEAT M2-94 GARAGE M1-95 PHOTO VSMOKE M1-95 GRND FLR OFFICE 011 x x x x x x x x ON M2-95 AM HEAT M2-95 GARAGE x x x x x x x x ON Candela BELL HORN 75cd HORN VISUAL o o m M1-96 PHOTO VSMOKE M1-96 GRND FLR CONFERENCE ROOM 012 x x x x x x x x ON M2-96 AM HEAT M2-9G GARAGE x x oN WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) ® 75 Celsius Device Type WP A/V WP A/V WP A/V Minimum Device � E M2-97 AM HEAT M2-97 SOUTH GARAGE STORAGE CLOSET 07 x x x x x x Supv. Current 0.0000 0.0000 0.0000 0.0000 0.0000 Voltage Spare Quantity = o y MI-97 ADRPIJL PULL M1-97 GRND FLR LOBBY 002 x x x x x x x x ON #` x x x x x x x x ON O M1-98 ADRPUL PULL M1-98 GRND ELK LOUNGE 007 x x x ON x x x oN Alarm Current 0.0530 0.1080 0.1380 0.0700 0.07OC Circuit NAC Circuit / Per € X X X X x M2-98 IAM HEAT M2-98 SOUTH GARAGE STORAGE CLOSET #537 x x x x x t x x x x ON Power Plan Dist. D Wire Wire Res. Total V. Drop Volt % Volt Min Device Max Capacity Output Branch Circuit/ o M1-99 RPHOTO SDUCT M1-99 1ST FLR AHU x x x x M2-99 IAM HEAT M2-99 SOUTH GARAGE STORAGE CLOSET #538 x x x x x x x x ON O Q M 1-100 PHOTO VSMOKE M 1-100 1ST FLR MAIDS CLOSET x x x ON x x x oN NOTIFICATION CIRCUIT DESCRIPTION Supply Ckt. Feet Gauge Ft. R Alarm A A*2D*R ® End Drop Voltage Distance Amps Terminals Capacity Branch U x x x x x M2-100 IAM HEAT M2-100 SOUTH GARAGE STORAGE CLOSET #539 x x x x x ti 0 d c X X x X ON OUTSIDE WATERFLOW HORN S-1 149a C 0.053 0.040 19.460 0.20% 16vdc 10755 Ft. 1 15 0 M1-101 PHOTO VSMOKE M1-101 2ND FLR MAIDS CLOSET x x x x M2-101 SPARE x x x x ON = a x x x x SPARE °S-1 49a 0.0031 0.000 0.000 9.500 0.00% 6vdc 0 Ft. A O M1-102 PHOTO VSMOKE M1-102 3RD FLR MAIDS CLOSET x X X x x X X x ON M2-102 IAM HEAT M2-102 GARAGE x x X x x x X x ON SPARE XPS-1 49a 0.0031 0.000 0.000 9.500 0.00% 6vdr_ 0 Ft. o m t M1-103 PHOTO VSMOKE M1-103 4TH ELK MAIDS CLOSET x x x x x x x x ON x x x x x ON M2-103 IAM HEAT M2-103 GARAGE X x X SPARE XPS-1 14 go 9 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft ,P O co M1-104 PHOTO VSMOKE M1-104 5TH FLR MAIDS CLOSET x x x x x x x x ON M2-104 IAM HEAT M2-104 GARAGE x x x x x x x x ON SPARE XPS-1 4 a 0 Ft. A � co 9 0.0031 0.000 0.000 19.500 0.00% 16� ,- U.T t� T w Y = M1-105 PHOTO VSMOKE M1-105 6TH FLR MAIDS CLOSET X X x x ON X x X X ON M � 3 x x x x M2-105 IAM HEAT M2-105 GARAGE x x x x SPARE XPS-1 4 a cn ¢ o f O 9 0.0031 0.000 19.500 0.00% 16v x 0 Ft. SA J 5 I i� J"r� w a CV M1-106 PHOTO VSMOKE M1-106 7TH FLR MAIDS CLOSET x x x x x x x x ON M2-106 AM HEAT M2-106 GARAGE x x x x x x x x ON r O M1-107 PHOTO VSMOKE M1-107 GRND FLR LOBBY 002 x x x x x x x x ON M2-107 PHOTO VSMOKE M2-107 EAST ELEVATOR LOBBY x x x x x x x x ON s M1-108 GENIAM SO M1-108 BSMT MAIN TAMPER x x x x x x x x ON M2-108 IAM HEAT M2-108 SOUTH PARKING GARAGE x x x x Ix Ix x x ON LODGE TOWER NAC PANEL #1 (EXISTING) 4009 NAC VOLTAGE DROPS PID 4906-9153 4906-9153 4906-9153 4906-9101 4906-9101 m o M1-109 PHOTO VSMOKE M1-109 GRND FLR TOP OF BSMT STAIRS x x x x x x x x ON M2-109 AM HEAT M2-109 SOUTH GARAGE STORAGE CLOSET 506 X x x x X ON y -0 w # x x x Candela 15cd 30cd 75cd 15cd 30cd z M1-110 SPARE x x x x x x x x ON M2-110 IAM HEAT M2-110 SOUTH GARAGE STORAGE CLOSET #207 x x x x x x x x ON WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) 75 Celsius Device Type S/V S/V S/V V/0 V/0 Minimum Device DRAWN BY: NSW s M1-111 SPARE x x x x x x x x ON M2-111 SPHOTO LATSUPV M2-111 UNIT 777 HALLWAY x x x x x x x x ON Supv. Current 0.0000 0.0000 0.0000 0.0000 0.0000 Voltage ® Spare Quantity CHECKED BY: SS M1-112 RZAM RELAY M1-112 ATTIC H&V UNIT SHUTDOWN x x x x x x x x ON M2-112 SPHOTO LATSUPV M2-112 UNIT 777 LIVING ROOM x x x x x x x x ON Alarm Current 0.0600 0.0940 0.1860 0.0600 0.0940 Circuit NAC Circuit / Per ISSUE DATE: 9/19/13 J M1-113 RZAM RELAY M1-113 ATTIC CTR SHAFT FAN VFD OVERRIDE x X x x x x x x ON M2-113 SPHOTO LATSUPV M2-113 UNIT 777 BED ROOM 1 x x x x x x x x ON Power Panel Plan Dist. (D) Wire Wire Res. Total V. Drop Volt % Volt Min Device Max Capacity Output Branch Circuit/ M1-114 GENIAM UTILITY M1-114 ATTIC CTR SHAFT FAN FAULT N C) x x x x x x x x ON M2-114 SPHOTO LATSUPV M2-114 UNIT 777 BED ROOM 2 x x x x x x x x ON NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Ckt. Feet Gauge Ft. R Alarm A A*2D*R ® End Drop Voltage Distance (Amps) Terminals Capacity Branch JOB#: M1-115 GENIAM UTILITY M1-115 ATTIC CTR SHAFT FAN CURRENT SENSR x x x x x x x x ON M2-115 SPHOTO LATSUPV M2-115 UNIT 777 BED ROOM 3 x x x x x x x x ON SPARE 4009 SIG1 N1:1 14go 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 2.A 19.5 100.0% 0 PROJECT#: 419:972539701 o t M1-116 PHOTO VSMOKE M1-116 BSMT ELECTRICAL ROOM X X x x x x x x ON M2-116 SPARE x x x x x x x x ON GROUND FLOOR VISUALS 4009 SIG2 N1:2 382 14ga 0.0031 1.006 2.360 17.140 12.10% 16vdc 567 Ft. 7 2 ? 1 2.A 19.5 32.6% 12 SIMPLEXGRINNELL© 2013 0 ° MI-117 PHOTO VSMOKE M I-117 GRND FLR N LOUNGE x x x x x x x x ON THROUGH ON SPARE 4009 SIG3 N1:3 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 2.A 19.5 100.0% 0 SYSTEM: N M1-118 ADRPUL PULL MI-118 GRND FLR VALET EXIT x x x x x x x x ON x x x x x x oN GARAGE SOUTH 4009 SIG4 N1:4 379 14ga 0.0031 1.324 3.081 16.419 15.80% 16vdc 431 Ft. 5 1 5 2.A 19.5 12.0% 11 w y M2-246 SPARE X x FIRE ALARM SYSTEM $ � Y c x x x x x x ON GARAGE NORTH 4009 SIG5 N1:5 283 9a 0.0031 1.270 2.207 17.293 11.32% 16vdc 449 Ft. 1 1 6 2.A 19.5 36.5% y M1-11J GENIAM WATER M1-119 GRND FLR BOILER CHASE WATER FLOW x x M2-247 IDNETISO SO IDNET+ ISOLATOR - CIRCUIT A x x x x x x x x ON X x x X X X X X ON SPARE 4009 S G6 N1:6 149a 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 2.A 19.5 100.0% 0 SHEET: 3 y M1-120 PHOTO VSMOKE M1-120 GRND FLR ELEVATOR LOBBY X X X X X x X x ON M2-248 IDNETISO ISO IDNET+ ISOLATOR - CIRCUIT B 9 0.0031 0.000 0.000 9.500 0.00% 16vdc 0 Ft. A 9.5 00.0% 0 a t M1-121 GENIAM SO M1-121 GRND FLR BOILER CHASE TAMPER x x x x x ON x x x x x x ON SPARE N1:7 14 a 2 X x X M2-249 IDNETISO SO IDNET+ ISOLATOR - CIRCUIT C X X y ° SPARE N1:8 149a 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 2_A 19.5 100.0% 0 A MI-122 SPARE x x x x x x x x ON M2-250 1DNETISO ISO IDNET+ ISOLATOR - CIRCUIT D x x x x x x 71716N°N UPGRADED 4100ES FACP M1-123 SPARE x X x X x x x x ON MI-124 SPARE x x x x x x x x ON CALCULATIONS AND M1-125 RZAM RELAY M1-125 ELEVATOR LOBBYS SMOKE DAMPERS x x x x x x x x ON SCHEDULES M1-126 PHOTO VSMOKE M1-126 GRND FLR LOBBY BY FIREPLACE x x x x x x x x ON m m N M1-127 HEAT HEAT M1-127 GRND FLR LOBBY BY FIREPLACE x x x x x x x x oN DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES LU o CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE s DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT PROGRAM INFORMATION AND ASSUMPTIONS OF SPEAKERS IN UNITS. PLEASE VERIFY ALL DEVICE LOCATIONS. M FA-601 y O Z � z � X d' T N d w - w a m ZONE SCHEDULE ZONE SCHEDULE LODGE TOWER - NEW TRANSPONDER 4100es XPDR Speaker Db Loss Calculations ZONE # POINT TYPE CUSTOM LABEL ZONE # POINT TYPE CUSTOM LABEL LODGE TOWER - NEW TRANSPONDER 4100es XPDR *Circuit Voltage = 70vrms [Et] MAXIMUM -3 dB DROP T FLR U . Z1 128 FIRE FLF 04-501 Standby Total Alarm Total Total Wire Est. Ckt.Wire Res. Circuit Speaker Speaker Voltage Watts Actual Max Allowable IRL 2ND FLR UN1 I-2U2) 72 129 FIRE FLR UNIT 290 (104-502) Z1 ,-; Module Qty Description Current Standby Current Alarm Plan Speaker Speaker Speaker Speaker Watts Gauge Length Per Foot Resistance Current Resistance At End At End dB Loss Ckt. Length °o- FIRE 3RD FLR UNIT :-: ; 0 Z3 130 FIRE FLR UNIT 390 (104-503) 2130 Panel Equipment SPEAKER CIRCUIT DESCRIPTION Circuit Tap Tap Tap Tap [P] [D] in [Rw] [RI=2D*Rw] [I=P/Et] [Rs=Et/1] [Es=(Et*Rs) [Pe=(Es)[dB=Log10 [ML=(0.414*Rs) N� 99 w IRE 4TH FLR UNIT 478 (101-204) Z4 131 FIRE IT R UNIT 490 (104-504) Z131 Amp # Number .25 Watt .5 Watt 1. Watt 2. Watt Feet Rs+RI *2/Rs] Pe P *10 2*Rw MM 4100-9600 1 BASIC TRANSPONDER * 0.0870 0.0870 0.0870 0.0870 F�F' S=EA LEIS a 1-1 a Ar=P-1 19 4.75 Watts 9a 320 0.0078 4.973 0.068 1031.579 69.664 4.705 -.04 db 27482 Ft. M M m FIRE 5TH FLR UNIT 578 (101-205) Z5 132 FIRE r UNIT 590 (104-505) Z132 CD - RE 6TH FLR UNIT 678 (101-206) Z6 133 FIRE FIFE UNIT 690 (104-506) 2133 4100-0621 1 ANALOG AUDIO RISER MODULE 0.0150 0.0150 0.0150 0.0150 - FLR SPEAKERS 101-102 Amp-1 - 23 5.75 Watts 1 gal 312 0.0078 4.848 0.082 852.174 69.604 5.685 -.05 db 22703 Ft. McM 7 FIRE 7TH FLR UNIT 778 (101-207) Z7 134 FIRE FLR UNIT 790 (104-507) Z134 4100-0634 2 POWER DISTRIBUTION MODULE 120V 0.0000 0.0000 0.0000 0.0000 T 1ST FLR SPEAKERS 101-103 Amp-1 Watts 9a 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. H FLR SPEAKERS 02-101 Amp-I ;1 23 5.75 Watts 9a 280 0.0078 4.351 0.082 852.174 69.644 5.692 -.04 db 22703 Ft. Z 8 FIRE 1ST FLR UNIT 180 (101-208) Z8 135 FIRE FLR UNIT 192 (104-508) Z135 O - 4100-0636 1 BOX TO BOX HARNESS KIT 0.0000 0.0000 0.0000 0.0000 /7TH FLR SPEAKERS 102-102 Amp-1 S5 Watts ga 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. _ FIRE 2ND FLR UNIT 280 (101-301) Z9 136 FIRE _'a UNIT 292 (104-601) 7136 CL LL 4100-0637 1 AUDIO BOX TO BOX HARNESS KIT 0.0000 0.0000 0.0000 0.0000 FLR SPEAKERS 102-103 Amp-1 S6 23 5.75 Watts 1 9a 288 0.0078 4.476 0.082 852.174 69.634 5.690 -.05 db 22703 Ft. x F RE 3RD FLR UNIT 380 (101-302) 710 137 FIRE FL LR UNIT 392 (104-602) 2137 4TH FLR SPEAKERS 102-104 Amp-1 S7 23 5.75 Watts 9a 296 0.0078 4.600 0.082 852.174 69.624 5.688 -.05 db 22703 Ft. O FIRE 4TH FLR UNIT 480 (101-303) Z11 138 FIRE 4T1-I FLR UNIT 492 (104-603) 7138 4100-0638 6 ADDITIONAL 24V HARNESS 0.0000 0.0000 0.0000 0.0000 Amp-1 S8 Watts 189a 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. j e 99 SERIES SPEAKERS 103-101 U, FIRE 5TH FLR UNIT 580 (101-304) Z12 139 FIRE FLR UNIT 592 (104-604) 2139 4100-1248 2 100 WATT EXPANSION NAC BOARD 0.0168 0.0336 0.0600 0.1200 791,793691 693 SPEAKERS 103-102 Amp-1 S9 8 2. Watts 18ga 320 0.0078 4.973 0.029 2450.000 69.858 1.992 -.02 db 65270 Ft. FIRE 6TH FLR UNIT 680 (101-305) Z13 140 FIRE FLR UNIT 692 (104-605) Z140 Amp-1 S10 Watts 1 ga 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. 4100-1315 2 ANALOG 100W AMP W/6 B NACS 120VAC 70V 0.0850 0.1700 3.8000 7.6000 ELEVATOR 3 LOBBY SPEAKERS 03-iO3 \ C)CD =IRE 7TH FLR UNIT 780 (101-306) Z14 41 FIRE FLR UNIT 792 (104-606) 2141 TI 7TH FLR SPEAKERS 104-101 Amp-1 S11 Watts go 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. aj cflo FIRE 1ST FLR UNIT 182 101-307 Z15 142 FIRE UNIT 194 104-607 Z142 4100-2300 5 EXPANSION BAY PHASE 10 ONLY 0.0000 0.0000 0.0000 0.0000 Am I S12 19 4.75 Watts 18ga 320 0.0078 4.973 0.068 1031.579 69.664 4.705 -.04 db 27482 Ft. °N LO ( ) ( ) I,�7TH FLR SPEAKERS 104-102 Amp- � a o� a FIRE 2ND FLR UNIT 282 (101-308) Z16 143 FIRE AND FLR UNIT 294 (104-608) 2143 4100-2320 2 AUDIO EXPANSION BAY KIT 0.0000 0.0000 0.0000 0.0000 BSMT FLR SPEAKERS Amp-2 S13 2 2 6. Watts ga 272 0.0078 4.227 0.086 816.667 69.640 5.938 -.04 db 21757 Ft. rn �°Or, FIRE 3RD FLR UNIT 382 (101-401) Z17 144 FIRE 3RD FLR UNIT 394 (104-701) Z144 4100-5005 22 ZONE MODULE, 8 IDC, CLASS B 0.0750 1.6500 0.1950 4.2900 GRND FLR SPEAKERS Amp-2 S14 2 2 5 6.5 Watts 189a 244 0.0078 3.792 0.093 753.846 69.650 6.435 -.04 db 20083 Ft. s Ic FIRE 4TH FLR UNIT 482 (101-402) Z18 145 FIRE 4TH FLR UNIT 494 (104-702) 7145 1ST FLR SPEAKERS Amp-2 S15 5 2.5 Watts l8ga 272 0.0078 4.227 0.036 1960.000 69.849 2.489 -.02 db 52216 Ft. w y FIRE 5TH FLR UNIT 582 (101-403) 719 146 FIRE F FLR UNIT 594 (104-703) 7146 4100-5101 3 EXPANSION PWR SUPPLY XPS - 120VAC 60HZ 0.0500 0.1500 0.0500 0.1500 2ND FLR SPEAKERS Amp-2 S16 5 2.5 Watts 9a 280 0.0078 4.351 0.036 1960.000 69.845 2.489 -.02 db 52216 Ft. �> _ FIRE 6TH FLR UNIT 682 (101-404) Z20 147 FIRE - FLR UNIT 694 (104-704) 2147 4100-5111 1 SYSTEM POWER SUPPLY SPS - 120VAC 60HZ 0.1750 0.1750 0.1850 0.1850 3RD FLR SPEAKERS Amp-2 S17 5 2.5 Watts 1 9a 288 0.0078 4.476 0.036 1960.000 69.841 2.489 -.02 db 52216 Ft. y N w w o FIRE 7TH FLR UNIT 782 (101-405) Z21 148 FIRE I FLR UNIT 794 (104-705) 2148 4100-5115 3 EXPANSION NAC MODULE - 3 NACS 0.0250 0.0750 0.0250 0.0750 4TH FLR SPEAKERS Amp-2 S18 5 2.5 Watts 189a 296 0.0078 4.600 0.036 1960.000 69.836 2.488 -.02 db 52216 Ft. 5TH FLR SPEAKERS Amp-2 S19 5 2.5 Watts 1 9a 304 0.0078 4.724 0.036 1960.000 69.832 2.488 -.02 db 52216 Ft. FIRE 1ST FLR UNIT 177 (102-301) Z22 49 FIRE BOILER RELIEF VALVE (104-706) 2149 4100-3002 1 4DPDT 24VDC RELAY 10 AMP 0.0150 0.0150 0.1750 0.1750 FIRE 2ND FLR UNIT 277 (102-302) Z23 150 FIRE ATTIC DETECTION (101-603) Z150 6TH FLR SPEAKERS Amp-2 S20 5 2.5 Watts 8ga 312 0.0078 4.848 0.036 1960.000 69.827 2.488 -.02 db 52216 Ft. w FIRE 3RD FLR UNIT 377 (102-303) Z24 51 FIRE LT ELEVATOR SHAF W (101-604) 2151 Panel Totals 2.3706 12.6970 7TH FLR SPEAKERS Amp-2 S21 5 2.5 Watts 1 ga 320 0.0078 4.973 0.036 1960.000 69.823 2.487 -.02 db 52216 Ft. y Notification Appliances GARAGE SPEAKERS Amp-2 S22 6 13 16. Watts 1 ga 659 0.0078 10.241 0.229 306.250 67.735 14.981 -.29 db 8159 Ft. o FIRE 4TH FLR UNIT 477 (102-304) Z25 152 FIRE ATTIC ELEV TOO SD (101-605) Z152 ���Q LICF S V M-C NON-ADDRESS, WHT, WALL SPARE Arnp-2 S23 Watts 9a 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. O FIRE 5TH FLR UNIT 577 (102-305) Z26 153 FIRE LT El EV MACHINE ROOM E (10 1-606) 2153 4906-9153 29 / 15 0.0000 0.0000 0.0600 1.7400 �. .••'•••`• W SPARE Amp-2 S24 Watts 9a 0.0078 0.000 0.000 0.000 0.000 0.000 db 0 Ft. pp.VI •. f�� - IF 6TH FLR UNIT 677 (102-306) 727 154 SPARE 7154 4906-9153 10 S/V M-C NON-ADDRESS, WHT, WALL 30 0.0000 0.0000 0.0940 0.9400 0 SPARE Z28 155 FIRE LT SOUTH WEST (103-208) 7155 Peripheral Totals 0.0000 2.6800 ;� �• 3 29 FIRE 1ST FLR UNIT 179 (102-308) Z29 156 =1E Z156 * Current draw included under "Device Addresses Used" (See "Additional Current Draws:") Total Standby 2.3706 Total Alarm 15.3770 LODGE TOWER - NEW TRANSPONDER 4100es XPDR VOLTAGE DROPS PID 4906-9153 4906-9153 4906-9153 4906-9101 4906-9101 3� 44967 30 FIRE 2ND FLR UNIT 279 (102-401) Z30 157 =1E 2157 1. 2-wire detector alarm current is included in the alarm current of the Initiating Device Circuit. Candela 15cd 30cd 75cd 15cd 30cd o•, g 31 FIRE 3RD FLR UNIT 379 (102-402) Z31 158 =F Z158 2. Backup Amplifier assumes Main Amplifier alarm current on failure. Device Type S S V S V V 0 V 0 •. 9/23/13 � P P P WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) © 75 Celsius yP /V / / / / Minimum Device p • 32 FIRE 4TH FLR UNIT 479 (102-403) Z32 159 Z159 � ••. .•• o •000060 Standby Standby Alarm Alarm Supv. Current 0.0000 0.0000 0.0000 0.0000 0.0000 Voltage ® Spare Quantity d' O� a 33 FIRE 5TH FLR UNIT 579 (102-404) Z33 160 L 2160 FIRE 6TH FLR UNIT 679 (102-405) Z34 161 -.FE Z161 Battery Set #1 (Cabinet/Charger 1 Current Total Current Total Alarm Current 0.0600 0.0940 0.1860 0.0600 0.0940 Circuit NAC Circuit / Per SPARE Z35 162 SPARE 2162 Select ALL Power Supplies on this battery set: Power Panel Plan Dist. (D) Wire Wire Res. Total V. Drop Volt % Volt Min Device Max Capacity Output Branch Circuit/ o 3e FIRE 1ST FLR UNIT 181 (102-501) Z36 163 SPARE 2163 SPS-1 2.0170 5.1690 NOTIFICATION CIRCUIT DESCRIPTION Supply Circuit Ckt. Feet Gauge Ft. R Alarm A A*2D*R ® End Drop Voltage Distance (Amps) Terminals Capacity Branch FIRE 2ND FLR UNIT 281 (102-502) Z37 164 SPARE Z164 XPS-2 0.0668 1.1120 BSMT FLR VISUALS SPS-1 SIG3 V1 272 149a 0.0031 0.342 0.571 18.929 2.93% 16vdc 1667 Ft. 1 3 3.A 19.5 83.7% 4 0 FIRE 3RD FLR UNIT 381 (102-503) Z38 165 SPARE 2165 XPS-3 0.0668 1.1120 SPARE SPS-1 SIG4 V2 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 FIRE 4TH FLR UNIT 481 (102-504) Z39 166 SPARE 7166 XPS-4 0.0500 0.3840 SPARE SPS-1 SIG5 V3 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 a -T FIRE 5TH FLR UNIT 581 (102-505) Z40 167 SPARE 2167 Amp-1 0.0850 3.8000 1ST FLR VISUALS XPS-2 SIG6 V4 272 14ga 0.0031 0.334 0.558 18.942 2.86% 16vdc 1707 Ft. 4 1 3.A 19.5 84.1% 5 t 0 41 FIRE 6TH FLR UNIT 681 (102-506) Z41 168 SPARE Z168 Amp-2 0.0850 3.8000 2ND FLR VISUALS XPS-2 SIG7 V5 280 14ga 0.0031 0.334 0.574 18.926 2.94% 16vdc 1707 Ft. 4 1 3.A 19.5 83.6% 5 0 42 SPARE Z42 169 SPARE 2169 Sub Total 2.3706 15.3770 3RD FLR VISUALS XPS-2 SIG8 V6 288 14ga 0.0031 0.334 0.591 18.909 3.03% 16vdc 1707 Ft.1 4 1 3.A 19.5 83.1% 5 4 FIRE 1ST FLR UNIT 183 (102-508) Z43 170 SPARE 2170 Additional Current Draws: SPARE XPS-2 SIG9 V7 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 n 44 FIRE 2ND FLR UNIT 283 (102-601) Z44 171 SPARE 2171 RUI Connected Peripheral Devices 0 x 0.0035 0.0000 x 0.0035 0.0000 SPARE XPS-2 SIG10 V8 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 45 FIRE 3RD FLR UNIT 383 (102-602) Z45 172 SPARE Z172 SPARE XPS-2 SIG11 V9 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 MAPNET/IDNet Device Addresses ordered / used 0 x 0.000000 = 0.0000 x 0.000000 = 0.0000 4! FIRE 4TH FLR UNIT 483 (102-603) Z46 173 SPARE Z173 4TH FLR VISUALS XPS-3 SIG12 V10 296 14ga 0.0031 0.334 0.607 18.893 3.11% 16vdc 1707 Ft. 4 1 3.A 19.5 82.7% 5 s 41, IRE 5TH FLR UNIT 583 (102-604) 747 174 SPARE Z174 Sub Total 2.3706 15.3770 5TH FLR VISUALS XPS-3 SIG13 V11 304 14 gal 5 9 0.0031 0.334 0.623 18.877 3.20% 16vdc 1707 Ft. 4 1 3.A 19.5 82.2% ,11 IRE 6TH FLR UNIT 683 (102-605) Z48 175 SPARE 7175 6TH FLR VISUALS XPS-3 ISIG14 V12 312 14ga 0.0031 0.334 0.640 18.860 3.28% 16vdc 1707 Ft.1 4 1 3.A 19.5 81.7% 5 w SPARE Z49 176 PARE 2176 Spare addressable point capacity 20% 0 x 0 0.0000 x 0 0.0000 SPARE XPS-3 SIG15 V13 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 FL 1ST FLR UNIT 185 (102-701) Z50 Total 2.3706 15.3770 SPARE XPS-3 SIG16 V14 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 0 FIRE 2ND FLR UNIT 285 (102-702) Z51 SPARE XPS-3 SIG17 V15 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 FIRE 3RD FLR UNIT 385 (102-703) Z52 Standby Time = 24 Hrs x 2.3706 56.8944 Standby Ah 7TH FLR VISUALS XPS-4 SIG18 V16 320 14ga 0.0031 0.334 0.656 18.844 3.37% 16vdc 1707 Ft. 4 1 3.A 19.5 81.3% 5 5 IRE 4TH FLR UNIT 485 (102-704) Z53 Alarm Time = 15 Min 0.25 x 15.377 3.8443 Alarm Ah SPARE XPS-4 SIG19 V17 14ga a FIRE 5TH FLR UNIT 585 (102-705) Z54 60.7387 9 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 E FIRE 6TH FLR UNIT 685 (102-706) Z55 Additional Spare Capacity = 20% + 12.1477 SPARE XPS-4 SIG20 V18 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 SPARE XPS-4 ISIG21 V19 14ga € I-IRE 7TH FLR UNIT 785 (102-707) Z56 728864 9 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 w FIRE 1ST FLR UNIT 187 (102-708) Z57 Battery Discharge Factor = 20%, SPARE XPS-4 SIG22 V20 149a 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 :N + 14.5773 SPARE XPS-4 SIG23 V21 14ga 0.0031 0.000 0.000 19.500 0.00% 16vdc 0 Ft. 3.A 19.5 100.0% 0 ~ FIRE 2ND FLR UNIT 287 (102-801) Z58 5=! FIRE 3RD FLR UNIT 387 (102-802) Z59 Minimum Battery Required 2081-9279 110AH (2x) 87.4637 FIRE 4TH FLR UNIT 487 (102-803) Z60 Battery Supplied 2081-9279 110AH 2x N 0 FIRE 5TH FLR UNIT 587 (102-804) Z61 6 FIRE 6TH FLR UNIT 687 (102-805) Z62 0 FIRE 7TH FLR UNIT 787 (102-806) Z63 DEVICES SHOWN ARE FROM RECORD DRAWINGS. ANY DEVICES FIRE 1ST FLR UNIT 199 (103-201) 764 CHANGES MADE IN THE FIELD WILL NOT BE REFLECTED ON THESE m 0 FIRE 2ND FLR UNIT 299 (103-202) 765 DRAWINGS. DEVICES IN INDIVIDUAL UNITS BASED UPON CURRENT m 66 FIRE 3RD FLR UNIT 399 (103-203) Z66 PROGRAM INFORMATION AND ASSUMPTIONS OF SPEAKERS IN UNITS. y 67 IFIRE 4TH FLR UNIT 499 (103-204) Z67 PLEASE VERIFY ALL DEVICE LOCATIONS. 68 FIRE 51H FLR UNIT 599 (103-205) Z68 69 FIRE 6TH FLR UNIT 699 (103-206) Z69 70 FIRE 7TH FLR UNIT 799 (103-207) Z70 w I� 8 71 FIRE 1ST FLR UNIT 197 (103-301) Z71 LO FIRE 2ND FLR UNIT 297 (103-302) Z72 o FIRE 3RD FLR UNIT 397 (103-303) Z73 OO 7�1 FIRE 4TH FLR UNIT 497 (103-304) 774 0 O o 75 FIRE 5TH FLR UNIT 597 (103-305) Z75 Q s 76 FIRE 6TH FLR UNIT 697 (103-306) Z76 0 _ 77 FIRE 7TH FLR UNIT 797 (103-307) Z77 w Q Q 78 DUCT ATTIC AHU DUCT DET (103-501) Z78 79 FIRE 1ST FLR UNIT 195 (103-505) Z79 O W O 0 8C� FIRE 2ND FLR UNIT 295 (103-506) Z80 s FIRE 3RD FLR UNIT 395 (103-507) Z81 Uj _ FIRE 4TH FLR UNIT 495 (103-508) Z82 Q V FIRE 5TH FLR UNIT 595 (103-601) Z83 Q J 84 FIRE 6TH FLR UNIT 695 (103-602) Z84 0 O 85 FIRE 7TH FLR UNIT 795 (103-603) Z85 T J CV > 86 FIRE 1ST FLR UNIT 193 (103-604) Z86 a E� 87 FIRE 2ND FLR UNIT 293 (103-605) Z87 0 ` 0 s a 88 FIRE 3RD FLR UNIT 393 (103-606) Z88 E w 8L1 FIRE 4TH FLR UNIT 493 (103-607) Z89 m FIRE 5TH FLR UNIT 593 (103-608) Z90 FIRE 6TH FLR UNIT 693 (103-701) 791 .3 W FIRE 7TH FLR UNIT 793 (103-702) 792 o g FIRE 1ST FLR UNIT 191 (103-703) Z93 N a FIRE 2ND FLR (UNIT 29 1 (103-704) Z94 N Z FIRE 3RD FLR UNIT 391 (103-705) Z95 CD or FIRE 4TH FLR UNIT 491 (103-706) Z96 s o m FIRE 5TH FLR UNIT 591 (103-707) Z97 w FIRE 6TH FLR UNIT 691 (103-708) Z98 Q I1 y RE 7TH FLR UNIT 791 (103-801) Z99 � o 00 FIRE 1ST FLR UNIT 189 (103-802) 7100 Q101 FIRE 2ND FLR UNIT 289 (103-803) Z101 z 3 0 102 FIRE 3RD FLR UNIT 389 (103-804) Z102 a <°> 103 FIRE 4TH FLR UNIT 489 (103-805) Z103 U o C0 16 104 FIRE 5TH FLR UNIT 589 (103-806) Z104 0 o m 105 FIRE 6TH FLR UNIT 689 (103-807) Z105 10i FIRE 7TH FLR UNIT 789 (103-808) Z106 Y y 107 FIRE 1ST FLR UNIT 184 (104-201) Z107 U 108 FIRE 2ND FLR UNIT 284 (104-202) 7108 109 FIRE 3RD FLR UNIT 384 (104-203) 7109 U 110 FIRE 4TH FLR UNIT 484 (104-204) Z110 o � 111 FIRE 5TH FLR UNIT 584 (104-205) 2111 0 0 0 112 FIRE 6TH FLR UNIT 684 (104-206) Z112 Q U) 113 FIRE 7TH FLR UNIT 784 (104-207) Z113 J ° m (-i 114 FIRE 1ST FLR UNIT 186 (104-208) Z114 co 115 FIRE 2ND FLR UNIT 286 (104-301) Z115 LU � 3 O 116 FIRE 3RD FLR (UNIT 386 (104-302) Z116 W < w CD FIRE 4TH FLR UNIT 486 (104-303) Z117 N FIRE 5TH FLR UNIT 586 (104-304) Z118 ° 1 19 FIRE 6TH FLR UNIT 686 (104-305) Z119 w 120 FIRE 7TH FLR UNIT 786 (104-306) 121 FIRE 1ST FLR UNIT 188 (104-307) s 122 FIRE 2ND FLR UNIT 288 (104-308) DRAWN BY: NSW = 123 FIRE 3RD FLR UNIT 388 (104-401) I2 CHECKED BY: SS ZT. t Q = FIRE 4TH FLR UNIT 488 (104-402) 1,= ISSUE DATE: 9/19/13 J = FIRE 5TH FLR UNIT 588 (104-403) JOB#: FIRE 6TH FLR UNIT 688 (104-404) PROJECT#: 419:972539701 o t 7TH FLR UNIT 788 (1c= SIMPLEXGRINNELL© 2013 s ; IDNET CHANNEL M1 SWITCH SETTINGS SYSTEM: .G t Address Device Type Point Type Location Description 1 2 3 4 5 6 7 8 FIRE ALARM SYSTEM M1-1 ISPARE x I x I x I x I x x x x ON THROUGH ON SHEET: m y a z M1-250 SPARE x x x x x x x x ON t 3 NEW 4100ES TRANSPONDER N � CALCULATIONS AND J 0 3 C N SCHEDULES U � f0 N T C N m N_ K 65 U a 0 o s F- w T Q U m M FA-602 O Z � X 5 � d' T N a y - w N d O N 1\ CR 09 DEVICE MOUNTING HEIGHT REFERENCE (PER NFPA 72) USE ONLY UL LISTED FIRE ALARM SIGNALING LINE (ADDRESSABLE) CIRCUITS SHIELDING EXAMPLE 9.A � MM 1O TWISTED SHIELDED PAIR CABLE UL LISTED FIRE PROTECTIVE SIGNALING CABLES MAY BE SELECTED FROM THE SIMPLEXGRINNELL WIRE & CABLE TABLE, #WIRE TABLE CLASS 'A' MM (TSP) FOR IDNETS, DATA COMM. + + - - A/C SUPPLY LINES, AUDIO, PHONE & SPEAKER z N VISUAL APPLIANCE MOUNTING HEIGHT CONSIDERATIONS IN SLEEPING ROOMS WIRING IN A FIRE ALARM SYSTEM. ° OR RETURN MIN. slzE Is 18-2 Awc SOLID sTP. PRODUCT INFORMATION 1 . MIN DISTANCE IN SLEEPING ROOMS IS 24 (610mm) FROM CEILING TO DIFFUSER THE 4 REQUIREMENT FOR SMOKE DETECTORS HAS cur WIRING TECHNIQUES FOR SHIELDED CABLE: d TOP OF LENS FOR 11OCD STROBES WITHIN 16' OF THE PILLOW BEEN REMOVED FROM THE 2010 EDITION OF NFPA 72 EXAMPLE: 2 #18-2 AWG SHIELDED • SHIELDS AND DRAINS MUST NEVER TOUCH GROUND. 2. 177CD STROBES, USED IN SLEEPING ROOMS, CAN BE WITHIN THE 24 0 TWISTED-PAIR CABLE • MOST GROUNDS ARE DUE TO SHIELDING ISSUES. ~ � 4 NOTE: MEASUREMENTS o (610mm) MINIMUM DISTANCE FROM THE CEILING. THE HIGHER 3' MIN • MOST SHORTS ARE SHIELD TO CONDUCTOR. i ( ) (102mm) SHOWN ARE TO THE y a� CD INTENSITY IS TO COMPENSATE FOR A POSSIBLE SMOKE LAYER. • BY CREATING A PROPER PROCEDURE FOR WIRE °ao� (914mm MIN) CEILING CLOSEST EDGE OF THE TRIM AWAY ONLY HANDLING WITH ADDRESSABLE CIRCUITS 'm . o°O`' DETECTOR. KEEP STHE DRAIN O MOST GROUNDS AND SHORTS CAN BE ELIMINATED. w WIRE UNDAMAGED. • ALL UNSHIELDED WIRE MUST BE ENTIRELY IN GROUND CONDUIT. m�w y CEILING MOUNTED , • CONDUIT SYSTEM MUST HAVE A GOOD REFERENCE TO EARTH GROUND N cower FOR CEILING HEIGHTS LESS THAN 86 (2180mm), NFPA 72 AUDIBLE APPLIANCE 4 • PIGTAILS, (T-TAP) WIRING IS PERMITTED TO ADDRESSABLE DEVICES C C14 FOR SMOKE/HEAT SHIELD FOR CLASS B CIRCUIT WIRING. THE VISUAL LENS MOUNTING HEIGHT SHALL BE 6 MIN (152.4mm MIN) DETECTOR (102mm) 12 (MAX) WITHIN 6 (150mm) OF THE CEILING. AUDIBLE ONLY BELOW FINISHED CEILING ( MAX) DRAIN WIRE y 305mm MAX PREPARE THE CABLE BY EXAMPLE FOR HEAT DETECTORS REMOVING 2" TO 4 OF 4 WIRING LABELING OO L/CF 90 MIN (2286mm MIN) ACCEPTED HERE NEVER HERE JACKET AS NEEDED. •� ••�s o •...... O ; ppVlp •.•F ABOVE FINISHED FLOOR WIRE A •o /OTHER MOUNTING HEIGHTS SHALL BE GENERAL WIRING GUIDELINES DISCARD TAG O:v� 9 RRE RRE L \ REUSE INSULATION p; r PERMITTED BY THE AHJ PROVIDING IT SHIELD N1.Mti 44967 ks 3 AUDIBLE VISUAL 1. ALL WIRING IS TO BE COPPER CONDUCTOR. ALL EQUIPMENT MUST / MEETS THE SOUND LEVEL OUTPUT REQUIRED. CLASS 'B' o:• BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS _ _ •. 9/23/13 & VISUAL ONLY WALL MOUNTED RECOMMENDATIONS AND THE SPECIFICATIONS AND STANDARDS + + per.•••• •'•�' APPLIANCES TO EXIT DOOR SMOKE/HEAT OF THE AUTHORITY HAVING JURISDICTION. THE INSTALLATION OF DRAIN WIRE TO PREVENT CONFUSION AND POSSIBLE F`rs�ONAL � ' ALL WIRING, CABLE AND EQUIPMENT MUST BE IN ACCORDANCE ERRORS, ALL WIRES MUST BE TAGGED. 5 (MAX.) DETECTOR WITH NFPA 70, NATIONAL ELECTRICAL CODE NEC), AND SPECIFICALLY SEE WIRE LEGEND FOR TYPES. 1524mm WITH ARTICLE 760, FIRE ALARM PROTECTIVE SIGNALING SYSTEMS; SYNCHRONIZE MORE THAN ( ) DOOR ARTICLE 800, COMMUNICATION CIRCUITS, WHERE APPLICABLE. 5 WIRES MUST BE CONNECTED WIDTH � SEPARATELY UNDER TERMINALS. 19 TWO APPLIANCES IN ANY 2. IF SHIELDED WIRE IS USED, THE FOLLOWING MUST BE OBSERVED: WIRE A CONTINUOUS WIRE LOOP o LESS 3 A. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND tFOR IS NOT ALLOWED. FIELD OF VIEW. 76mm INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE. STRIP OFF APPROX. ( ) B. SHIELDS SHALL ONLY BE CONNECTED AT THE CONTROL UNIT. 1-2 INCHES OF USH REUSED INSULATION SHIELD MUST NOT BE CONNECTED TO, OR TOUCH CONDUIT, ELECTRICAL BLACK INSULATION TO AREFULLY DOWN INTO ONLY CLASS B IDNET, MAPNET OR BOXES, OR ASSOCIATED HARDWARE AT ANY POINT. SLIDE ONTO DRAIN WIRE. ACKET. SECURE WITH DATA COMM. CABLE MAY BE 96" MAX (NFPA) 5" SIDE WALL C. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER LECTRICAL TAPE. T-TAPPED. IT MUST BE DONE (2440mm MAX) (127mm THAN 1 MEGOHM TO EARTH. IN A JUNCTION BOX WITH D. ALL CONDUCTORS ARE TO BE FREE OF SHORTS AND GROUNDS. CABLE STRAIN RELIEF I.EABOVE FINISHED FLOOR 3. UNDERGROUND WIRING MUST BE LISTED FOR APPLICATION AND FREE OF ALL WATER. CORD CLAMP/BUSHING, AND REF. 80" MIN (IBC) MANUAL 4. WIRING OTHER THAN THAT CONNECTED TO ELEVATOR CABS MUST NOT BE RUN TAPE WRAPPED AS SHOWN HERE. TO TOP OF LENS REDUCE EXPOSED 6(2032mm MIN) PULL IN ELEVATOR SHAFTS (REF.NFPA 70, ARTICLE 620). ABOUT 5 16" TO O 5. WIRING IN DUCTS, PLENUMS AND OTHER AIR HANDLING SPACES MUST BE LISTED / DRAIN WIRE STATION INSERTION INTO BREF. 96 MAX (IBC) FOR PLENUM USE AND INSTALLED IN ACCORDANCE WITH NFPA 70, ARTICLE 300. STRIP THE INSULATED WIRES 80 (ADA) (2032mm) FIRE 6. SPLICING IS PERMITTED IN ACCORDANCE WITH NFPA 70. ALL JUNCTIONS MUST OR SCREW-CLAMP ABOUT 5/16" TO 3/8" FOR (2440mm MAX) " PHONE MAGNETIC BE INSULATED AS SOUNDLY AS THE ORIGINAL JACKET. CONTINUITY OF ANY SHIELD INSERTION INTO BOX-TYPE OR 80 MIN (NFPA) (2032mm MIN) (WHERE USED) MUST BE MAINTAINED. ELECTRICAL TAPE. SCREW-CLAMP TERMINALS ON ABOVE FINISHED FLOOR TO BOTTOM OF LENS JACK DOOR 7. ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT. 0 THE ADDRESSABLE DEVICE. • HOLDER 8. THE COMMUNICATION CIRCUIT MEETS THE OPERATIONAL CHARACTERISTICS DEFINED FOR A STYLE 4 "" f € `b°i"" ' ® AND STYLE 6 SIGNALING LINE CIRCUIT. MAXIMUM WIRE RUN NOT TO EXCEED 2500 FT. ° FINISHED 9. ALL CIRCUITS ARE SUPERVISED AND POWER-LIMITED UNLESS OTHERWISE INDICATED. SHIELD WIRES ARE NOT SUPERVISED. SECURELY TWIST t • ® WALL 10. OPERATING POWER, FOR IDNet DEVICES, MUST ORIGINATE FROM A POWER-LIMITED POWER SUPPLY LISTED FOR FIRE DRAIN WIRES NOTE: REFER TO THE PROPER DEVICE PROTECTIVE SIGNALING USE OR, FROM THE F.A. CONTROL PANEL POWER SUPPLIES INDICATED IN THE APPROPRIATE -- THE SHIELD/DRAIN IS NEVER TOGETHER INTO DIAGRAM. MAXIMUM WIRE NOT TO EXCEED 1 KM (3270 FT). CONNECTED TO THE DEVICE. WIRE NUT. INSTALLATION INSTRUCTIONS 48 MAX (ADA) (1219mm) Y 11. WHEN COMMUNICATION WIRING OR OPERATING WIRING LEAVES THE BUILDING, OVERVOLTAGE PROTECTORS ARE WIRES MUST BE FOR BACKBOX MOUNTING HEIGHT. REQUIRED; USE 2081-9044 INSTALL ONE WHERE IT LEAVES THE BUILDING AND ONE WHERE IT ENTERS THE NEXT BUILDING. TIGHT ENOUGH 48 MAX (NFPA) (1219mm MAX) 12. TO PREVENT CONFUSION AND POSSIBLE ERRORS, TAG ALL CONDUCTORS, CODE AT INSTALLATION, TO IDENTIFY TO HOLD SECURELY FINISHED CIRCUIT ASSIGNMENT, POLARITY AND IN OR OUT DIRECTION OF THE WIRING. LOG ON AS-BUILTS. AND NOT SLIP OUT 42 MIN (NFPA) (1067mm MIN) TWIST THE BARE DRAIN FLOOR 13. LEAVE ADEQUATE SLACK IN THE WIRING TO ALLOW FOR TROUBLE SHOOTING. WIRES TOGETHER AND TRIM OF WIRE NUT. MEASUREMENTS SHOWN ARE SIMPLEXGRINNELL IS NOT RESPONSIBLE FOR ELECTRICAL CONTRACTOR'S WIRE CONDITIONS. TO ABOUT 1-1/2". JOIN TO TOP OF PULL HANDLE 14. IDNet COMMUNICATION LINE SPECS.: THEM WITH ELECTRICAL WIRE MAX. 36 VDC @ .5A 15. IDNET MAXIMUM NUMBER OF DEVICES: NUT. 3333 BAUD NON-CODED 250 3352 MAX. LINE RESISTANCE CODED PIEZO BASES 43 MAX. w `s 217 ADDRESSES STILL AVAILABLE FOR OTHER DEVICES. END— OF—LINE RESISTOR CODES 4100ES BACKBOX INSTALLATION 0 t INSTRUCTIONS 0 1. REMOVE ELECTRONIC CARD CAGE (IF PRESENT) W NOTE: REFER TO PANEL/MODULE AND DEVICE INSTALLATION AND STORE IT IN A SAFE DRY AREA. Q ° INSTRUCTIONS FOR PROPER TERMINATIONS. w 0 Q 2. NO KNOCKOUTS PROVIDED. CUT CONDUIT/SERVICE ENTRANCE OPENINGS. REFER TO FIG.1 FOR PROPER LOCATIONS. SYSTEM CONDUIT (D O � 0 * USE WITH RETROFIT OR HIGH CURRENT MODULE CONDUIT PROTRUSION INTO BOX 1/2' MAX. 3/4" MINIMUM Q Lu — 3. MOUNT BOX TO WALL: BOX MUST BE LEVEL AND PLUMB. 11 11/16" (2" CONDUIT SHOWN) (9 V $ REFERENCE FOR SURFACE MOUNT USE TEAR DROP AND CLEARANCE HOLES O J MODEL OHMS 1ST BAND 2ND BAND 3RD BAND 4TH BAND 5TH BAND WATTS CIRCUIT TYPE FIRE ALARM PANEL MODULE 6 29/32" 24„ O NUMBER PANEL/MODULE BACK SURFACE. 1 7/16" 0 O > Q 4081 -9001 733-892 2.2K RED RED RED GOLD N/A 1/2 ANNUNCIATOR (4300) 4004, 4010 (TROUBLE) FOR SEMI-FLUSH MOUNT: USE WALL STUD GUIDES FOR MAXIMUM J J CV ALLOWABLE BOX DEPTH TO PROVIDE OPEN DOOR CLEARANCE. 4 3/4" o N.O. INITIATING 4004*, 4004R, 4005*, 4006, USE KNOCKOUTS ON SIDE WALL, SCREW OR NAIL BOX TO WALL STUDS. 16" PULL, t KNOCKOUT a T PULL, SMOKE, HEAT, 4100, 4120, 41000, ZAM S 4. MINIMUM DISTANCE BETWEEN ANY TWO BOXES IS 3 1/4" (6" MAXIMUM). SCREW/NAIL y o 4081 -9002 733-893 3.3K ORANGE ORANGE RED GOLD N/A 1 WATERFLOW, TAMPER, ETC. 5. IF PRESENT, USE WIRE MANAGEMENT BRACKETS ON BOX SIDES HOLES FOR ` w 24 PT. I/O SWITCH SUPV. 4605-7401 , 4100 SERIES TO SECURE WIRE RUNS. SEMI-FLUSH 3 D 3 MOUNT ` CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM (EOLR) 6. NEMA RATING: NEMA 1 - GENERAL PURPOSE. (SEE NOTE 3.) 4081 -9003 733-896 4.7K YELLOW VIOLET RED GOLD N/A 1/2 3: / / NOTIFICATION (DACT) 2080-9024 7. DO NOT LOCATE POWER-LIMITED WIRING IN THE SHADED AREAS z OF THE BACKBOX, THIS AREA IS RESERVED FOR NON-POWER WALL STUD GUIDES s N.O. INITIATING 4004, 4005, LIMITED CIRCUITRY SUCH AS AC POWER, BATTERIES AND CITY (SEE NOTE 3.) y 0 4081 -9004 733-886 6.8K BLUE GREY RED GOLD N/A 1/2 PULL, SMOKE, HEAT, 4090-9001 IDNET IAM CONNECTION. a > WATERFLOW, TAMPER, ETC. 2190-9173 MAPNETII 2 PT 1/0 8. REFER TO SIMPLEX BACKBOX INSTALLATION DOCUMENT E y 4-20MA ZAM TROUBLE 579-117 FOR DETAILED INSTRUCTIONS. ° z � ° `n CURRENT LIMITED N.O. INITIATING ° 4081 -9005 733-984 1 .8K BROWN GREY RED GOLD N/A 1/2 (IN LINE) 4090-9001 IDNET IAM NOTE: ADA REQUIREMENTS LIMIT THE ALLOWABLE PROTRUSION OF OBJECTS N o MOUNTED IN PUBLIC ACCESSIBLE WALKS, HALLS, CORRIDORS, w € 4081 -9006 733-890 560 n GREEN BLUE BROWN GOLD N/A 1 N.C. INITIATING (EOLR) 4005*, 4090-9001 IDNET IAM PASSAGEWAYS OR AISLES. THE 4 INCH (100mm) RESTRICTION SEE FOR SURFACE MOUNT 1 .0 4100, 41000 APPLIES TO ANY ITEM IN WHICH THE MEASUREMENT FROM THE CHART USE 4 HOLES TO SECURE = .29 FLOOR TO THE BOTTOM OF THE UNIT IS MORE THAN 27 INCHES. BACKBOX TO WALL v z 4081 -9007 733-891 1 .2K BROWN RED RED GOLD N/A 1 N.C. INITIATING (EOLR) 4005 ° L f 2 4081 -9008 733-894 10K BROWN BLACK ORANGE GOLD N/A 1/2 NOTIFICATION 4004, 4005, 4006, 4008, y a 4009, 4010, 4100, 41000 PKG. SIZE PID NUMBER BOX HEIGHT s 66" = a 1 BAY 2975-9407 22 w 9 4081 -9009 733-912 20,'2 RED BLACK BLACK GOLD N/A 1 TO MR-101 RELAY COIL 4005 8 POINT 1/0 (TYPICAL, FOR a co r� 2 BAY 2975-9408 40 5 FOOT HEIGHT i� ° y t M N.C. INITIATING (ACROSS CONTACTS) 4005*, 4090-9001 IDNET IAM 3 BAY 2975-9409 56" TO LCD DISPLAY co 0 4081 -9010 733-973 1 K BROWN BLACK RED GOLD N/A 1 24 PT. I/O (ACROSS CONTACTS) 4605-7401, 4100 SERIES 1 BAY 2975-9410 22" CENTERLINE) 5 17 32" �' Q a E N CURRENT LIMITED N.O. INITIATING 2 BAY 2975-9411 40" / Lu � CD IN SERIES WITH CONTACT 4090-9001 IDNET IAM 3 BAY 2975-9412 56" 3 17 32" EXTERNAL a / BATTERY AREA BATTERY CABINET --- 0 4081 -9011 733-974 100n BROWN BLACK BROWN GOLD N/A 1/2 ANNUNCIATOR (N2) 4006 4008 4010 1 BAY 2975-9438 22" u (IF APPLICABLE) (IF APPLICABLE) ' ' 2 BAY 2975-9439 40" NO CONDUIT ENTRY OR (FOR USE WITH y z 4081 -9012 733-985 22K RED RED ORANGE GOLD N/A 1/2 SPEAKER CIRCUIT 4003 WIRING IN THIS AREA 110 AH BATTERIES) DRAWN BY: NSW 4081 -9013 734-086 4.99K YELLOW WHITE WHITE BROWN BROWN 1/2 3 BAY 2975-9440 56" CHECKED BY: SS / TYPICAL CONDUIT ISSUE DATE: 9/19/13 t N.C. INITIATING LOCATION PID NUMBER BOX HEIGHT BOX LENGTH BOX DEPTH JOB#: 4081 -9014 734-092 2.4K RED YELLOW RED GOLD N/A 1/2 SECURITY MONITORING EOLR) 4090-9001 IDNET IAM ( 2081-9280 12" 26 1/2" 12" PROJECT#: 419:972539701 o t CURRENT LIMITED N.O. INITIATING 4090-9001 IDNET IAM 00000 4081-9306 13 1/2" 27 7/8" 14 5/8" SIMPLEXGRINNELL© 2013 4081 -9015 734-093 1 .5K BROWN GREEN RED GOLD N/A 1/2/ / (SECURITY MONITORING EOLR) WALL 4081-9308 13 1/2" 27 7/8" 14 5/8" SYSTEM: FIRE ALARM SYSTEM 4081 -9016 734-149 150K BROWN GREEN YELLOW GOLD N/A 1/2 4081 -9017 734-171 3.9K ORANGE WHITE RED GOLD N/A 1 FIG. 1 FLOOR SHEET: L 4081 -9018 734-168 10K BROWN BLACK ORANGE GOLD N/A 1 70VRMS CONSTANT SUPV. NACS 4100-1260 378-090 8.2K GRAY RED RED GOLD N/A 1/2 SECURITY MONITORING (EOLR) 4100, 41000 WIRING TYPICALS 378-046 5.6K GREEN BLUE RED GOLD N/A 1/2 N.O. SECURITY MON. (SERIES) 4100, 41000 y U N 378-069 12K BROWN RED ORANGE GOLD N/A 1/2 N.C. SECURITY MON. (SHUNT) 4100, 41000 m LU N Cn M n ° � v t 11J T Q U m FA-701 O Z M `m Z X F mG � T N d w E m d N_ w TrueAlert TM NON—ADDRESSABLE MULTI— CANDELA SPEAKER/VISIBLE NOTIFICATION APPLIANCE PRODUCT INFORMATION 4098 - 9792 STANDARD SENSOR BASE MM PRODUCT INFORMATION FEATURES: MM is FEATURES: (WALL M 0 U N T) • UL LISTED, FM APPROVED z • TRUEALARM ANALOG SENSING PROVIDES DIGITAL TRANSMISSION OF ANALOG 4" X 1 1/2"R DEEP OCTAGONAL _� • UL LISTED TO STANDARD 1971 & 1480 SENSOR VALUES VIA MAPNETII, OR IDNet TWO WIRE COMMUNICATIONS O \ il." STANDARD ELECTRICAL BOX MOUNTING • FIRE ALARM CONTROL PANEL PROVIDES: X •ADA COMPATIBLE STANDARD ELECTRICAL BOX MOUNTING 4" SQUARE BOX, 1-1/2" DEEP, 4" SQUARE X 1 1/2" DEEP WHICH REQUIRES p -INDIVIDUAL SENSITIVITY SELECTION FOR EACH SENSOR V E • OPTIONS FOR WALL MOUNT SPEAKER VISUALS: 4" SQUARE BOX, 1-1/2" DEEP, WITH A 4" SQUARE BOX EXTENSION, -PEAK VALUE LOGGING ALLOWING ACCURATE ANALYSIS FOR SENSITIVITY SELECTION A 4098X SUPPLIED ADAPTER PLATE (6-3/8' X 1/4") cn - SKIRTS FOR SURFACE MOUNT ELECTRICAL BOXES WITH A 4" SQUARE BOX EXTENSION, 1-1/2" DEEP, SUPPLIED BY OTHERS �� pip -AUTOMATIC ENVIRONMENTAL COMPENSATION BOX SUPPLIED BY CONTRACTOR 1� o RED 4905-9946, WHITE 4905-9947 1-1/2" DEEP, SUPPLIED BY OTHERS p p -DISPLAY OF SENSITIVITY IN PERCENT PER FOOT o - 4905-9998 WIRE GUARD �O SURFACE MOUNT ADAPTER SKIRT p -MULTISTAGE ALARM OPERATION al oo TRANSPARENT HOUSING p �— 0 -ABILITY TO DISPLAY AND PRINT DETAILED SENSOR INFORMATION IN PLAIN ENGLISH LANGUAGE MAPNETII/IDNet ADDRESS DIP SWITCHES AND LENS ASSEMBLY �p 3 3/16" (81mm) DEEP. 0 0 0 SEE BASE INSTALLATION INSTRUCTIONS �ooM a SYNCHRONIZATION FLASH RATE MODE FOR USE WITH: CONDUIT CUTOUTS ARE PROVIDED • PHOTOELECTRIC SMOKE SENSOR 4098-9714: ° 0 SEVEN LEVELS OF SENSITIVITY FROM 0.2% TO 3.7% 574-709 FOR SETTINGS o • SEPARATE STROBE SYNCHRONIZATION MODULES THAT ARE AVAILABLE 0 °0 ON ALL FOUR SIDES. °0 O U o 0 ° • IONIZATION SMOKE SENSOR 4098-9717: �w� FOR CLASS B OR CLASS A OPERATION O °0 ° FOUR LEVELS OF SENSITIVITY FROM 0.5% TO 1.7%. i �> 0 0 • HEAT SENSOR 4098-9733: � c o N REMOVABLE COVER WIRING INPUT TERMINALS AND -RATE-OF-RISE TEMPERATURE DETECTION IS SELECTABLE AT THE CONTROL PANEL FOR EITHER 151F 4098-9714 PHOTOELECTRIC SMOKE SENSOR (TOOL REQUIRED) ° OR 20'F PER MINUTE e SPECIFICATIONS: ° SPEAKER TAP SELECTION ARE 4098-9717 IONIZATION SMOKE SENSOR ° B ACCESSIBLE FROM REAR -FIXED TEMPERATURE SENSING IS INDEPENDENT OF RATE-OF-RISE AND PROGRAMMABLE TO OPERATE ° ® w AT 135'F OR 155'F • HOUSING DIMENSIONS: 7-1/4" H X 5" W X 2-5/8" D (184mm X 127mm X 67mm) SPEAKER ASSEMBLY ° 1) -TRUEALARM HEAT SENSORS CAN BE PROGRAMMED AS A UTILITY DEVICE TO MONITOR ° FOR TEMPERATURE EXTREMES IN THE RANGE FROM 32' F TO 120' F. 4098-9733 HEAT SENSOR •TEMPERATURE RANGE: 32'F TO 122'F (0 TO 50'C) STROBE ASSEMBLY �Q,�DO Ll��cy • UL STANDARD SPACING: • HUMIDITY RANGE: 10% TO 93% NON-CONDENSING AT 100'F (38'C) I INTENSITY SELECTION -60 FT SPACING FOR 135° F •�pAo:sFO •TERMINAL BLOCKS FOR 18AWG TO 12AWG; TWO WIRES PER INTENSITY SELECTION PLUG, ACCESSIBLE ONLY -40 FT SPACING FOR 155' F 9 TERMINAL FOR IN/OUT WIRING. 15° PLUG, ACCESSIBLE ONLY I FROM REAR OF HOUSING; • INTEGRAL RED LED FOR POWER-ON (PULSING), OR ALARM OR TROUBLE (STEADY ON) G. STROBE INTENSITY 5 FROM REAR OF HOUSING; �° FACTORY SETTING IS 15cd :Q 44967 VIEWING SLOT FACTORY SETTING IS 15cd 75 • BASE MOUNTED ADDRESS SELECTION: 44 WIRING NOTES: STROBE INTENSITY 15 -ACCESSIBLE FROM FRONT (DIP SWITCH UNDER SENSOR) FLUSH MOUNTING �•6• 9/23/13 -ADDRESS REMAINS WITH ITS PROGRAMMED LOCATION p 1. NOTIFICATION APPLIANCES ARE RATED PER INDIVIDUAL NAMEPLATE LABEL. VIEWING SLOT • FOR USE WITH SIMPLEX 4010, 4100, 4020, AND 4120 SERIES CONTROL PANELS. ®® (BOX TO BE FLUSH OR RECESSED 1/4" MAXIMUM) #.6000206069 �FSS6 �C'\� 2. MAINTAIN CORRECT POLARITY ON TERMINAL CONNECTIONS. DO NOT LOOP SEMI-FLUSH MOUNT • MAXIMUM QUANTITY OF DEVICES: ONAL� w WIRES UNDER TERMINALS. IMPORTANT! -127 FOR 4020, 4100, 4120 3. ALL NAC WIRING CONNECTIONS ARE SUPERVISED AND POWER-LIMITED. WALL MOUNT INSTALLATION SURFACE MOUNT OPTION —25o FOR 4010, 4100 • MOUNTING: CEILING OR WALL 4. SEE INSTALLATION INSTRUCTIONS (579-548) FOR ADDITIONAL INFORMATION. HEIGHT REFERENCE • COLOR : FROST WHITE y 2975-9145 4" SQUARE BOX OUTLINE • BASE DIMENSIONS: 15/16" X 4-7/8" BOX OUTLINE STROBE: 4" SPECIFICATIONS: r • RATED VOLTAGE RANGE: UL LISTED: 16 VDC TO 33 VDC PER UL 1971 • UL LISTED TEMPERATURE RANGE: 32°F TO 100°F g ULC LISTED: 20 VDC TO 30 VDC PER ULC S526-M878 OPERATING TEMPERATURE RANGE: 32'F TO 120'F • FLASH RATE: 1 Hz HUMIDITY RANGE: 10% TO 95% RH • SYNCHRONIZED MODE NAC LOADING: MAXIMUM OF 35 SYNCHRONIZED STROBES PER NAC CIRCUIT. 1-1/2" PHOTOELECTRIC SENSOR AIR VELOCITY RANGE: 0-2000 FT/MIN TrueAlert SPEAKER IONIZATION SENSOR AIR VELOCITY RANGE: 0-300 FT/MIN WPM =ssis. t *CURRENT DRAWS REFLECT STROBE FLASHING JUMPER SETTINGS 78-1/2" NFPA 72 REQUIRES THAT • WIRING CONNECTIONS: SCREW TERMINALS FOR IN/OUT WIRING #18 TO #14 AWG MIN. THE ENTIRE LENS BE NOT � ""� atR °_ HOUSING LETTERING STROBE RMS CURRENT ® • COMMUNICATIONS MAPNETII/IDNet: 1 ADDRESS PER BASE JUMPER WATTAGE LESS THAN 80" AND NOT VOLTAGE •R— t MODEL NUMBER COLOR COLOR RATING 16 VDC 18 VDC 24 VDC POSITION VOLTAGE 82" (MAPNETII/IDNet): 24-40VDC ams amn 4906-9151 RED WHITE 15cd 60 mA 53 mA 40 mA SETTING MIN. GREATER THAN 96" ABOVE CURRENT: 400uA TYPICAL + 30cd 94 mA 84 mA 63 mA A TO TAP A 1 4 THE FINISHED FLOOR. J1 75cd 186 mA 165 mA 124 mA TO TAP B 70.7VRMS 1/2 DESCRIPTION: 1 TRUEALARM SENSOR BASES CONTAIN INTEGRAL ADDRESSABLE ELECTRONICS 110cd 252 mA 224 mA 168 mA 2 THAT CONSTANTLY MONITOR THE STATUS OF THE DETACHABLE PHOTOELECTRIC, 4906-9153 WHITE RED 15cd 60 mA 53 mA 40 mA J1 A 1 4 IONIZATION, OR HEAT SENSORS. EACH SENSOR'S OUTPUT IS DIGITIZED AND v v T 30cd 94 mA 84 mA 63 mA A TO TAPE 25VRMS 1/2 TRANSMITTED TO THE SYSTEM FIRE ALARM CONTROL PANEL EVERY FOUR SECONDS. E 75cd 186 mA 165 mA 124 mA A TO TAP F 1 SPKR - SPKR - SINCE TRUEALARM SENSORS USE THE SAME BASE, DIFFERENT SENSOR TYPES m 110cd 252 mA 224 mA 168 mA J1 TO TAP G 2 CAN BE EASILY INTERCHANGED TO MEET SPECIFIC LOCATION REQUIREMENTS. THIS I I I I I € SPKR + SPKR + FEATURE ALLOWS INTENTIONAL SENSOR SUBSTITUTION DURING BUILDING CONSTRUCTION. Ae SPEAKER: 4906 s 4906 s 4906 s END-OF-LINE WHEN CONDITIONS ARE TEMPORARILY DUSTY, INSTEAD OF COVERING THE SMOKE SENSORS. I I I I = FREQUENCY RESPONSE: FIRE ALARM: 400 TO 4000Hz RESISTOR (VALUE HEAT SENSORS MAY BE INSTALLED WITHOUT REPROGRAMMING THE CONTROL PANEL, GENERAL SIGNALING: 125 TO 12kHz - SPKR + SPKR + SPKR DEPENDANT ON FACP) ALTHOUGH THE CONTROL PANEL WILL INDICATE AN INCORRECT SENSOR TYPE, THE HEAT I I I •, FROM AUDIO NAC CHANNEL f SPKR + SENSOR WILL OPERATE AS A DEFAULT SENSITIVITY PROVIDING HEAT DETECTION FOR SPEAKER OUTPUT RATINGS ® 10 FT. (3m) (4100/4003) (SEE WIRING NOTES) l SPKR SPKR - SPKR - SPKR - BUILDING PROTECTION AT THAT LOCATION. ti 1/4W 1/2W 1W 2W FROM STANDARD NAC OR ll NAC + WIRING: + _ _ _ I _ _ _ _ _ _ I _ _ _ + COMPATIBLE SIMPLEX SMARTSYNC _ STROBE + STROBE + STROBE + 1. ALL WIRING TO COMPLY WITH LOCAL CODE. REVERBERATE CHAMBER 76 dBA 79 dBA 82 dBA 85 dBA NAC OR FROM SMARTSYNC CONTROL NAC FROM PREVIOUS UL 464 TEST STROBE - STROBE - STROBE - 2. CONDUCTORS MUST TEST FREE OF ALL GROUNDS. SHIELD _SHIELD SHIELD TO ADDITIONAL MAPNETII/IDNet DEVICES MODULE (SEE WIRING NOTES) 3. MAINTAIN CORRECT POLARITY MAPNETII/IDNet DEVICE —Z OR RETURN TO FIRE ALARM CONTROL t ANECHOIC CHAMBER 87 dBA 90 dBA 93 dBA 96 dBA 4. MAPNETII/IDNet WIRING TO BE #18 AWG TWISTED SHIELDED PAIR OR FIRE ALARM _ PANEL FOR A STYLE 6 APPLICATION y NAC - w,c - 5. IF SHIELD IS USED, TWIST SHIELD WIRES TOGETHER AND CAP WITH CONTROL PANEL =2 WIRE NUT. SHIELD SHOULD BE INSULATED FROM ELECTRICAL BOX. NAC + NAC±j 6. REFER TO INSTALLATION INSTRUCTIONS (574-707) V V 7. REFER TO APPLICATION MANUAL (574-709) w � o OO 0 woo0 Lu N O w O a o � J0 Lu Q V a � E R L N N T C d 0� V C C 3 � c C V! N C O C p C .0 A2 • N Z C N O G m N @ 0 0 E W �v E N Q m O Z 3 w C R U o W m 0 € c m c � Y c •� O N a � m r Q � o C7 'v d c p W $ E co y _j p J w N M W Y c C) O N Q 3 E 0 N U(V ° m o N � � 3 z DRAWN BY: NSW CHECKED BY: SS € U) ISSUE DATE: 9/19/13 r JOB#: PROJECT#: 419:972539701 o 0 SIMPLEXGRINNELL© 2013 SYSTEM: y L FIRE ALARM SYSTEM C t0 H .0 SHEET: ti H V � N N W � C y 'N a WIRING TYPICALS `0 3 OI N O = U U y t0 m N N_ K Cn c n O LLI T Q U m M FA-702 F Z � x F w Q„' T 04 y