Loading...
HomeMy WebLinkAboutF10-0080 (2) ' I � �-�����' - ` Department of Community Development � ` ��� ��;,,,r , ��I 75 South Frontage Road �.�;, r. � �.e� � � ,_ :,, �*,,..� ' �'. � _�_: . ' � r� `� � Vail, Colorado 81657 � �� �Tel: 970-479-2128; �; `. �� � ��` ► , r��`"�� Fax: 970-479-2452 t� . , �� 7 +�� ,., �y . e, , i, . ����� � - Web: www.vailgov.com . ` �Deyelopment Review Coordinator . �t � � ; ,�IP�'i . ,iw4u , � ��� �_ � . � � � � ul��u� � ��.� ,,` i `' sx. ..y.��� _ . r.�.�.vid��"�c�Y�� FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: Office Use: 174 S. Gore Creek Drive Eng/Office ;� Project#: ?'Q��� �(���p (Number) (Street) (Suite#) ` Lod e at Vail Building Permit#: ������[� Building/Complex Name: 9 Sprinkler Permit#: }'��� �Q�� Contractor Information: Lot#:_Block# Subdivision: Company: Western States Fire Protection Company Address: �026 S.Tuscan Way Detailed Description of Work: Relocate Sprinkler Ciry: Centennial State: CO Z;p;80112 pipe and heads (7), add (2)to accommodate Contact Name: Joe Hayden remodel of engineering offices Contact Phone: 303-549-8979 (use additional sheet if necessary) E-Mail Joe.hayden@wsfp.us Detailed Location of Work: Work will be preformed in Town of Vail Contractor Registration No.: 338-S old storage-new Eng/Offices X Does a Monitored Fire Alarm Exist? Yes(�) No( ) Contractor Signature(required) �«� -� ��/�� Does a Sprinkler System Exist? Yes(�) No( ) Property Information Work Class: Parcel#: 2�0108281001 (For parcel#,contact Eagle County Assessors O�ce at 970-328-8640 or New( ) Addition( ) Remodel(�) Repair( ) visitwww.eaglecounty.us/patie) Retro-Fit( ) Other( ) Tenant Name: S.R.E. Builders, Inc. Type of Building: Owner Name: Lodge Properties Inc. Single-Family( ) Duplex( ) Multi-Family( ) Commercial(�) Restaurant( ) Other( ) Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler$: $4,678.00 Date Received: (� � (� � n/7 � n �'_-� �5 1J U OCt o 4 2010 ��,mAi� TOWN OF VAIL Ol-Feb-10 Western States Fire Protection Co. � ' ,�iue� a�d ��c�i�n� Material Submittal FOR Lod e at Vail-En /Offices g g 174 E. Gore Creek Drive Vail CO 81658 Tenant Remodel Prepared by: Jeff Hagan Project Manager Western States Fire Protection Co. 7026 S.Tucson Way Centennial,CO 80112 Phone(303)792-0022 Fax(303)792-9049 Cell(303-549-9553 Email jeff.hagan@wsfp.us WSFP#CS0956 September 30,2010 MATERIAL INDEX Description Model Manufacturer I. Sprinkler Heads A.Standard Spray Quick Response Semi-Recessed Sprinkler F1FR Reliable B.Sprinkler Head Guards Model D-1 Reliable II. Pipe—Copper A. Copper Type M ASTM B 75 Varies** III. Copper Fittings Varies Varies** IV. Pipe Hangers(Per NFPA 13) A. Standard Pipe Clamps 33942 Oatey B. Suspension Pipe Clamp 33937 Oatey C. All Thread Rod Fig. 100 Tolco D. Adjustable Copper Ring Hanger Fig.202 Tolco **Because of the current escalation occurring with steel,WSFP reserves the right to substitute pipe as required to meet project schedules. Bulletin 136 Re�.M � o Model F1 FR W o e ecesse �� Quick Response � S rinklers � - - - - � Model F1 FR Sprinkier Types Standard Upright � Standard Pendent � � Conventional � �" Vertical Sidewall Horizontal Sidewall ,,,,,, : - HSW 1 Deflector ` -- Model F1 FR Recessed prinkler Types � del F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Insta tion Wrench: Model D Sprinkler Wrench Installati Data: --- - --- __ _.._..._ _.-- Sp er Type K Factor 5 nkler ldentiflcatlon Standard-Upright(S and Pendent(SSP) ' � Sprinkler Approval Number(SIN� I Deflectors Marked to � te Position US Metric Height Organlzation SSU SSP - __------ --__ —..__ �" 15mm Standard Orifice with!"N '� Thread 5.6 80 2.2"(56mm�__ 1,2,3, , ,7 R3625 R3615 " " 20mm Lar e Orrfice with a"'NPT R3/a Th d 8.0 115 2.3" 58mm ,3,4,7,8 R3622 R3612 ? " 17mm Small Orifice with�"NPT R,`z)Thread 42 60 2.2" 56mm 1,2,8 R3623 R3613 ?'" 10mm)Small Orifice with 7z"NPT Ry2 Thread 2.8 40 2.2" 56 1,2,8 R3621 R3611 10mm Orifice XLH with R3B"Thread 60 5 4,6,7 R3624 R3614 Converttional-Install in U ri ht or Pendent Position 10mm Orifice XLH with R�B Thread 4.2 0 , 56mm — R3674 � 15mm Standard Orifice with,i2'NPT(R,2)Thread 5.6 56mm 4,6,7 R3675 i 20mm Lar e Orifice with 3/;'NPT(R3/+Thread 8.0 I 115 ' S8mm 4,7 R3672 I I:M ' � � � �: ' I � .� � �..�.r(� � � = pright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler I Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: — _ _ --_ _......._ . ___— -- ----- Nominal Thread K Factor Sprinkler Approval�'� Sprinkler ldentificatlon Orifice Size US Metrlc Height Organizations Number(SIN) �" (15mm �"NPT RYz 5.6 80 2.2"(56mm 1,2,3,4,5,7,8 R3615 "32'(20mm) � ?,"NPT(R3/<) 8.0 115 2.3"(58mm) 1,2,3,8 R3612 --...—..—._.._._..-- - ------- ?;s' (11mm) -Z'NPT(R'/z) 4.2 60 2.2"(56mm) 1,2,8 R3613 ?e" (10mm) }2�NPT(RYz) 2.8 40 22"(56mm) 1,2,8 R3611 10mm 1 R?e 4.2 60 56mm _ 4,7 R3614 ���Refer to escutcheon data table for approvals and dimensions. . ��E�_t a I '� - ':'L �''1. (W.7r•.���! r.. ' - ::<kL iN CC�.'�: �;5'..m., , " i f3i�ri''w i i� � ' .�'!�D.F. (yJ>._..r: � �— (a9;mT,' ', �U? , }s� �.� � I--'-.�,�,'����-� — . � .. :F.E�:��rs � I I I I . ! r�� i,(n ' ` . . � __� ___�_J ^'� ' • ..,. a,N.�/,^���`.`'�\ � I � � ' \ I I I y.��- � _� � I I � J �-_; �- '' �1� � ti � �' .,-- �-� - - - ,- � .m : 4!'./S7YF�N, I J� Vb . -•--.-. ,...;� :�.;��; �� � � � �� � ' � � 0 S�VtI � . , - - - - � , , ���+.•. ' . ,_ ..�_ i i? . . � -� , '.� � -; , �� �--m- - r r=--- �� � -�� <<� �� � , , � . ,;,�; .-_._ -:� _ � �.,� I �, •,-, , 1 ;zTi�:',:u v". ���- •- ..)I.+rJ _._ ._,:�7r � �.... _ � IN�.r.I � �:lr� ' ii 6 -/f:.".� . ...1.. 'n!.MF .. . .�4.- t�. �1�..�i l_, .�� r� �rl.�it�:. �l�'f .,.� ._,��1. -f'�.Ai: . _�,1.��::_'M:� 2. Installation Quick response sprinklers are intended for installation as cleaning fluids. Remove dust by using a soft brush or gen- specified in NFPA 13. Quick response sprinklers and stan- tle vacuuming. Remove any sprinkler which has been dard response sprinklers should not be intermixed. painted (other than factory applied) or damaged in any The Model F1 FR Recessed Quick Response Sprinklers are to way. A stock of spare sprinklers should be maintained to be installed as shown. The Model F1 or F2 Escutcheons illus- allow quick replacement of damaged or operated sprin- trated are the only recessed escutcheons to be used with the kiers. Prior to installation, sprinklers should be maintained Model F1 FR Sprinklers. The use of any other recessed escutch- in the original cartons and packaging until used to mini- eon will void all approvals and negate all warranties. mize the potential for damage to sprinklers that would When installing Model F1 FR Sprinklers,use the Model D Sprin- cause improper operation or non-operation. kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers,use the Model GFR1 Sprinkler Wrench. Any Sprinkler Types other type of wrench may darnage these sprinklers. Standard Upright Glass bulb sprinklers have orange bulb protectors to minimize Standard Pendent bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER Conventional SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION.R� Sidewall(Vertical, Horizontal HSW1) moval of the protectors before this time may leave the bulb vul- Recessed Pendent nerable to damage. RASCO wrenches are designed to install Recessed Horizontal Sidewall HSW1 sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Finishes"'`�' TO REMOVE THE PROTECTORS. Standard F�nishes _ S rip nkler__ Escutcheon Temperature Ratings _—__-__ � _..�_..._._..__.___—_ Bronze Brass i Sprinkler � Chrome Plated Chrome Plated�3� Classiflcatlon Temperature , Max.Ambient ' Bulb -- Temp. Color White Polyester Coated White Painted -- — --�°_. -. -- I Ordinar C oF�- ' �S ecial Applicatfon Fnishes Ordinary 68 155 100°F 38'C I Red S rinkler Escutcheon ( ) Bright Brass Bright Brass n erme ia e 7g 175 150'F 66'C Yellow Intermediate 93 200 150°F(6G'C) Green High��� 141 286 225°F(107°C) Blue �I Black Plated Black Plated ��� I Black Paint Black Paint Not available for recessed spri�klers. Off White Off White ESCUtCh@OIl D8t8 Satin Chrome Satin Chrome '- ��F� — (�1 Other finishes and colors are available on special order. ,� ng � qd��� p� � ���i�a Consult the factory for details. � ' __.._WaIlDirnension �2) FM Approvals is limited to bronze and brass,chrome or black - - _.,._------ � ' �j�^ plated finishes only. Max Recess (38.1mm) �;,°-'�6° �3� FP Push-on/Thread-ott escutcheon F1 1,2,4,8 Min Recess 3;" (5mm-24mm) i9.imm Ordering Information y Specify: F2 1,2,3,4,5,7,8 Max Recess (38.1mm) �;6"-'y,fi" Min Recess 'S,6° (5mm-17mm) 1. Sprinkler Model 24mm 2. Sprinkler Type Fp i,2 MaxRecessed �s� iy°(38.1mm) , 3. Orifice Size P�Sn� 11mm 4. Deflector Type j Thread-o8 �,p MinRecessed �'s� 1"(254mm) _._zamm ____ _ _ 5. Temperature Rating No Dimensional Figure for FP 6. Sprinkler Finish 7. Escutcheon Type Maintenance 8. Escutcheon Finish (where applicable) The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system Note: When Model F1 FR Recessed sprinklers are maintained in accordance with NFPA 25. Do not clean ordered, the sprinklers and escutcheons are packaged sprinklers with soap and water, ammonia or any other separately. The equipment presented in this bulletin is to be installed in accortlance with the latest pertinern Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with Ihe provisions of governmental codes or ordinances whenever applicable. Products manutac[ured and distributed by Reliable have been protec[ing Ifte and property tor over 80 years,antl are installetl and servicetl by the most highly qualifietl and repu[a- ble sprinkler contractors locatetl throughout the United States,Canada and toreign countries. Manufactureci by � 0 The Reliable Automatic Sprinkler Co.,Inc. � R P��d ��''��' (S00)431-1588 SalesOftices � (800)84�6051 SaleS Fax Revision lines indicate updated or new tlata (914)668-3470 Corporate Offices www.refiablespiinkler.com Internet Address EG.Prin�ed in U.S.A 7/05 P�N9999970027 Bulletin 208 Re�.F � o Sprinkler Guards W �� N O � • Model D � � �''`,�;;;�,'�i��ir i Model C Sprinkler Guards , odel C Series sprinkler guards are designed t e � ..� � as mbled onto installed sprinklers. They are � ''� con ucted of heavy gauge wire welded t steel . ='�`��"*f mount g plates and finished with zinc plati . Other ,V��- ,`; � finishes are available. Guards protect utomatic . � sprinklers in locations where they are subject to �� �- ' ; -� -� � physical d age. Refer to guard sele ion table for '�' 4� � � listing and a proval information reg ding specific „�. sprinkler and ard combinations. , .k r � All Model C gu rds are certifie y FM Approvals. � l �i, Models C-2 and C- also have c Lus Listings. . � �._,��.�'t�''" • Model C-1 ��-j�fs._,:_ Model C-1 guards ar us d with pendent, upright, ~� horizontal sidewall and v ical sidewall sprinklers. • Model C-2 Model D1 Sprinkler Guard Model C-2 guard are u d with pendent dry sprinklers. • Model D-1 • Model C-3 Model D-1 guards can be assembled to pendent, upright and horizontal sidewall sprinklers. Model C-3 g rds have a water hield attached. When asse led to an upright prinkler, the • Model D-3 and D-6 combination is for upright intermedi te sprinkler odel D-3 and D-6 guards have a water shi d applicatio . att hed and are assembled to upright spri ers. • Mode C-5 The rinkler guard assembly is for pright interme ' te level sprinkler applicatio . Mo I C-5 guards are supplied with a wate hield and -Ring which are assembled to the spr kler • Model D-4 d D-5 bef re the sprinkler is installed. The guard is t en Model D-4 an -5 guards are 1 guards supplied i talled to the sprinkler after it is installed in t with an original wate hield w ' is threaded on('h") tting. or passed over (3/a") t rinkler inlet thread. The combination forms a dent intermediate level Model D Sprinkler Guards sprinkler. The Model D Series sprinkler guards are Guards and er shields are inished with zinc supplied as kits to be assembled to the sprinkler at plating. Othe nishes are available on request. the job site before sprinkler installation. The kit consists of the guard, Y2" and 3�4�� locknuts and a All Mo D Guards are cULus List . Refer to water shield when being used as an intermediate guard election table for listing and proval level sprinkler. The pendent intermediate has an info ation regarding specific sprinkler and ard 0-Ring supplied. binations. Each guard type is fabricated of heavy gauge Patents: wire welded to steel mounting plates and complies USA Patent Number 5,893,418 with the latest UL standards. Guards protect Applies to Model D Series Guards automatic sprinklers in locations where physical damage can occur. Listings &Approvals Model D Series guards are also available factory �. Listed by Underwriters Laboratories, Inc. and assembled on the sprinkler ready for immediate UL certified for Canada(cULus) sprinkler/guard installation. Consult factory for 2. Certified by FM Approvals availability. 3. NYC MEA 258-93-E 4. Scientific Services Laboratories (SSL, Australia)* * For Models C1, C2, C3 guards. The Reliable Automatic Sprinlder Ca,Inc. • 525 Nath Mac�uesten Parkway • Mount Vemon • New York � 10552 Model D-3 Guards � � Model D-5 Guard i sHOww roon c�/s' rrr SrRw+uu sxown roori v� �/2' Nrr sPJfNK�r rreerwr..nwreurc ��p ya Model D-4 Guards � -� Model D-6 Guards ,m.� I ,">!, -..-:- -r:r- '��r.-i-y'"r�� �, � 145:31 L�Y Nfi.cmwr�ea YO�L_L_�tLG2:: :.'1' hP ^,_____.�_irr;.�'�3�w_e _—_ __�m��— 3. Guards are approved to be used with sprinklers listed below. Approvals with SIN Number Guard Model� Sprinkler Model S rinkler T Application p YPe Orifice Sizes MEAn�,SSLm cULus FM� R3611, R3613,R3615, R3612, R3621,R3623, R3625, R3622, R3111, R3113, R3115,R3117, R3121, R3123,R3125, R3127, R3635, R3131, Pendent, Upright, 3/8",7/16",�/z", R3133, R3135,R3137, D-1 G,GFR,F1,F1FR HSW ���32„ R1711, R1713,R1715, R1712, R1721,R1723, R 1725,R 1722,R 1735, R1011,R1013, R1015, R1016, R1017, R1021, R1023, R1025, R1026, R 1027, R 1231,R 1233, R1235, R1236,R1237 R3625,R3622,R3125, D-3 G,GFR,F1,F1FR Upright Intermediate Yz", 17/32" R3127,R1725,R1722, R1025, R1026, R1027 D-4 G,GFR,F1,F1FR Pendent Intermediate yz^, 17/32 R3115,R3117 (Large Shield) Pendent Intermediate R3615, R36 , 1715, D-5 G, F1, R Y2", 17/32 R1712, 15, R1016, (Small Shield) R10 D-6 G XLO ' ht Intermediate 0.64 R2921 R1011,R1015,R1016, R1017, R1021,R1025, Pendent,Upright, R1026, R1027,R1235, C-1 G, F1, F1FR HSW,Vertical 3�8„ Y2� ���32„ R1285,R1712,R1715, Sidewall, Upri R1721,R1725,R1735, Pendent R1785, R3612,R3615, R3622,R3625,R3635, R3685 C-2 F3,F3QR Pendent ��Z� R , R5314, R5314,R5714 R5714, 4216 R3625,R3622, �25, R3625, R1725, C-3 ,GFR, F1,F1FR Upright Intermediate /z", 17/32" R3127, R1725,R1 1025, R1027 R 1025, R 1026,R 1027 R1015, 17, -5 G, F1,F1FR Pendent Intermediate '/z", 17/32" R3615,R17 R1712,R3612 (�1 MEA approval on D-1,D-3,D-4,D-5,C-2,and C-3 «�SSL approval on C-1,G2,and C-3 �3�Model GFR does not have FM Approval. �41 Sprinkler guards are listed and approved only for use with specific sprinklers. The use of any other guards on these sprinklers may impede their operation or distribution and negate all approvals and warranties. 4. Overall Cage Size: • Model D Guards Before a sprinkler is installed into a fitting,assemble MQdels C-1. C-2. C-5 the guard on the sprinkler using the same technique 2%" (73mm) High X 2�;" (70mm) Diameter described above for the Model C Guards. Then install a Y2" or 3/0" locking nut on to the NPT threads Models C-3. D-3. D-6 until the nut is tight against the guard. Each guard is �2/" (70mm) High X 4y" (114mm) Diameter supplied with both size of locking nuts. The assembly of sprinkler and guard is then wrenched into place using an adjustable wrench maximum Models D-1 D-5 size 8" and a jaw opening of iY"(for D-1, D-3, D-4 2/" (67mm) High X 3" (76mm) Diameter or D-5)or an adjustable wrench maximum size 10" and a jaw opening of 1%e' (for D-6). Model C-4 Wrench must be placed over the guard. Do not 2/s" High X 4Y" Diameter use the wrench directly on the sprinkler wrench boss. The sprinkler wrench boss requires a stallation Instructions special wrench. • el C Guards With b cups unhooked, slightly sprea pen the Finish guard. Ins steel plate into the inst d sprinkler Standard Finish—Zinc with chromate dip. between the th ds and the wrenc ats. The steel Other finishes, quoted on request. plate tabs should i the sprinkler ench flats and four contact points engage e sprin r neck. For Model C-2, the stee ate fits into the groove in Ordering Information each wrench flat and the ar ' located by the notch in • Guard Type (D-1,D-2 etc.) both steel plates. • Finish (Standard or other) Snap the farth ocking clip into pla , then close the near clip. The ard is now securely insta d in place. If • Sprinkler Inlet Thread Size, locking cli equires too much force to sna losed or D-4& D-5 Guards Only. open, � tly flex the wires on both sides of the � and • Optional: Consult Factory for assembly on eith close or open the clip. sprinkler. Specify Sprinkler: –Type. –Temperature Rating. – Finish. • Wrench: Not supplied by Reliable 5. _ ... • • . � � • • - � i � � � � � � � ii Maximum O D. • 1 12G5 inches(28 613 mm) Nominal O.D - 1.1250 inches(28 575 mm) Minimum O D, = 1.1235 inchtts(28 537 mm) Nominal I.D. = 1 0558 inches(26.791 mmi Nominal Wall Thir.kness = 0.0350 inches(0 8a9 mm) Flow Area = 0.8742 sq inches(Sb3.98 s�mm) Haren Williams Pormula C Factor = 150 FLOW.Q Pressure Loss Head Loss Velocity FLOW,Q Pressure Loss Head Loss Velociry (GPM) (psi/1D0 ft) (fV100 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 2.50 0.18 0.41 0.92 158 0.04 0.41 0.28 ----- - __.. _ 5.00 0.64 1.49 1.84 315 0.14 1.49 0.56 7.50 136 3.75 2.75 473 0.31 3.15 0.84 10.00 2.31 5.37 3.61 631 0.52 5.31 1.12 12.50 3.49 8.11 4.59 789 0.79 8.11 1.40 15.00 4.90 11.36 5.51 946 1.11 11.36 1.68 1Z50 6.52 15.11 6.42 1104 1.47 15.11 1.96 20.00 8.34 19.35 7.34 1262 1.89 19.35 224 22.50 10.38 24.06 8.26 1479 2.35 24.06 2.52 25.00 12.61 29.24 9.18 1577 2.85 29.24 2.80 27.50 15.05 34.88 10.09 1735 3.40 34.68 3.08 30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36 32.50 20.51 47.51 11.93 2050 4.64 41.51 3.64 35.00 23.52 54.49 12.85 2208 5.32 54.49 3.92 _-- 31.50 26.73 61.91 13.76 2366 6.05 61.91 4.19 40.00 30.12 69.16 14.68 2523 6.81 69.76 4.4J 42.50 33.10 78.04 15.60 2681 7.62 78.04 4.15 45.00 37.47 86.14 1fi.52 2839 8.47 86.74 5.03 47.50 41.41 95.81 17.43 2997 9.37 95.87 5.31 50.00 45.54 105.41 18.35 3154 10.30 105.41 5.59 52.50 49.84 115.31 19.27 3312 11.28 115.31 5.87 55.00 54 33 12574 20.19 3470 1219 125]4 6.15 1 ' 1 1 1 1 II •., .. . ,.,�-, _ -.�..,�,.r _: .: . . , ?,. r�,lilD ' ]S[,,i, • �.: _.., P.1i i . ��I'i - i ';r�;.i� .�.. PLnun�l I.U. 'ca:i0 in� i i (Ic3 n,-�.�� Normnal Wall Tnirkn�°,; = U.Dti5U mrhes�1.651�mm)� Flow Area � 12U4 sq.inches Q85-41 sG mm) Hazen Williams(ormula C Factor - 150 FLOW.Q Pressure Loss Head Loss Velociry FLOW.Q Pressure Loss Head Loss Velacity (GPM) (psi/100 ft) ((t/700 ft) (ft./sec.) (cu.cm/sec.) (kPa/100 m) (m/100 m) (m/sec.) 5.00 0.29 0.67 1.32 315 0.06 0.67 0.40 10.00 1.03 2.40 2.64 631 0.23 2.40 0.80 15.00 2.19 5.08 3.95 946 0.49 5.08 1.20 20.00 3.73 8.65 5.27 1262 0.84 8.65 1.61 25.00 5.64 13.06 fi.59 1577 1.27 13.06 2.01 30.00 7.90 18.30 7.91 1893 1.19 18.30 2.41 35.00 10.51 24.34 9.22 2208 2.38 24.34 Z.81 40.00 13.46 31,17 70.54 2523 3.04 31.17 3.21 45.00 16.74 38.15 11.86 2839 3.79 38.75 3.61 50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02 55.00 24.27 56.18 14.49 3470 5.49 56.18 4.42 60.00 28.52 65.99 15.81 3785 6.45 65.99 4.82 65.00 33.07 76.52 17.13 4101 7.48 76.52 5.22 70.00 37.94 87.76 18.45 4416 8.58 87.76 5.62 7500 43.71 99Jt 19.77 4732 9J5 9971 G02 - - --------- - --- -- 80.00 4D.58 112.35 21.08 5047 10.99 112.35 6 43 U.S.customary units in this document are the s[andard;the metric units are provided for reference only.The vaiues stated in each system are not exact equivalents. NIBGO INC.WORLD HEAD�UARTERS•1516 MIDDLEBURY ST.•EIKHART.IN 4G516-4740•USA•PH:1.800.234.0227 m TECH SERVICES PH�1.888-446.4226•FAX:1.800.234,0551•WTERNATIONAL SERVICE PH:«1.574.295.3221 •FAX:+1.574.295.3455 � www.nibco.tom _ . . . • � • • ,, TEES continued i !� ' ♦ :� � G - � C �--►�--F 611 NOTE:T ���zes.zr��r�,ad R � ;�on x� ���=� TeeCxCxC - Wrot �. �� � •� � � , ' �;e o,�� , � __ 3/16=,r, 0.01 '/3z /�z '/3z 5/8 x 5/8 x 3/4 0.15 ��hz "/s2 '/z ---- - __. __ i 1/8 0.02 '/a i/a '/3z 5/8 x 5/8 x 1/2 0.11 'hs '/te 13I32 1/8 x 1/S x 1/4 0.02 13/sz 13I32 'la 5/8 x 5/8 x 3/8 0.09 �hs �he 5/e 1/8 x 1/8 x 3/1600 0.01 '/a �/a 5/is 5/8 x 5/8 x 1/4 0.09 1/ie '/is 3/a 1/8 x 3/160.o x 1/8 0.01 '/a '�/3t �/3Z 5/8 x 1/2 x 5/8 0.10 �he 5/e '/ie 5/160.0. 0.02 �/s 3/a 5/is 5/8 x 1/2 x U2 0.09 1hc 19/sz 13I32 5/16n.o.x 5/16o,n x 1/4 0.02 3/a 3!a '/a 5/S x 3/8 x 5/8 OJO �hs 3/< �he 5/160.o x 5/160o x 1/8 OA2 3�8 3�B 13I32 5/8 x 3/8 x 3/8 �.�9 ��16 3�4 5�8 5/l600.x1/8x5/16ou 0.02 3/a t3/3z SIl6 3/4 0.15 '/z '/z '/z 5/160o x 1/8 x 1/8 �.�2 3�8 13I32 13�32 3/4 x 3/4 x 1 �.22 23I32 z3I32 ��2 1/4 OA2 5/,s 5/is '/a 3/4 x 3/4 x 5/8 0.16 "/3Z "/az "/,s 1/4 x 1/4 x 1/2 0.06 '°/3z 19I32 3/e 3/4 x 3/4 x 1/2 0.12 '/�s '/ie "/3z 1/4 x 1/4 x 3/8 0.04 "/3z ��/sz "/sz 3/4 x 3/4 x 3/8 0.12 �hs �hc 21/sz 1/4 x 1/4 x 5/1600 0.02 SIl6 5�16 S�tfi 3/4 x 3/4 x 1!4 �.�2 13I32 13I32 23�32 1/4 x 1/4 x 1/8 0.02 5/is 5I16 13�32 3/4 x 3/4 x 1/8 0.12 �/ie �he 13I16 1/4 x 1/4 x 3/l60.0 0.02 SI76 SIt6 �/is 3/4 x 5/8 x 3/4 0.15 ��/3z '�hs �/Z 1/4 x 5/160o x 1/4 0.02 5/ie 3/e �/a 3/4 x 5/8 x 5/8 0.15 ��/3z 23I32 ��/ts 1/4 x 1/S x 1/4 0.02 5/is 73/sz '/a 3/4 x 1/2 x 3/4 0.15 "/az 2S/3z �/z 1/4 x 1/8 x 1/8 OA2 5/is 13/az 3/e 3/4 x 1/2 x 1/2 0.12 13/3z 19/3z �/z 3/8 0.04 "/3z "/sz "/3z 3/4 x 1/2 x 3/8 0.12 'hs 21/sz z1/3z 3/8 x 3/8 x 1/2 0.07 "/3z '�/3z 3/e 3/4 x 3/8 x 3/4 0.15 '�/3z '�/az �/z 3/8 x 3/8 x 1/4 0.04 "/az "/3z 'S/3z 3/4 x 3/8 x 1/2 0.12 '/�e 23I32 "/az 3/8 x 3/8 x 5/l60 0. 0.04 "/3z ��/sz "/sz 3/4 x 3/8 x 3/8 0.12 �hs 23I32 Z'/3z 3/8 x 3/8 x 1/8 0.04 ��/3z '�/3z ��/az 7�g 0.31 23I32 23/32 23/sz 3/8 x 1/4 x 3/8 0.04 "/3z "/3z "/3z ii n z, 318 x 1/4 x 1/4 0.04 "/sz '�/3z 15/sz 1 x 1 x 1 1/2 0.60 ���I32���I32 3'/3z 3/8 x 1/4 x 1/8 0.04 '�/3z ��/3z 9I16 1 x 1 x 1 1/4 0.42 1 1 �/sz 3/8 x 1/8 x 3/8 0.04 "/sz 79/sz "/3z 1 x 1 x 3/4 0.27 9�16 9/�e 11/sz 3/8 x 1/8 x 1/8 0.04 "/3z 19I32 19/3z 1 x 1 x 5/8 0.26 9II6 9/ie 7/e 1/2 0.06 �Vsz "/3z �V3z 1 x 1 x 1/2 0.23 �SI32 15/3z �3I32 1/2 x 1/2 x 1 0.29 1 1 21/sz 1 x 1 x 3/8 0.23 15�32 15/sz Z9I32 1/2 x 1/2 x 3/4 0.12 "/3z "/3z "/3z 1 x 1 x 1/4 0.23 �S/az �SI32 1 1/2 x 1/2 x 5/8 0.11 5/s 5/a '/is 1 x 3/4 x 1 0.29 "/�s '/a Z'/3z ��2 X��Z X 3�8 �.Q� 5�16 5�16 13I32 1 x 3/4 x 3/4 �.26 9�16 23�32 3�4 ��2 X��2 X��4 �.�6 5/16 5�16 9�16 �X 3�4 X��2 �.22 15�32 z��32 23I32 1/2 x 3/8 x 1/2 0.07 'hs '�/az 3/e Continues... 1/2 x 3/8 x 3/8 �.�6 SI16 ���32 73I32 1/2 x 3/8 x 1/4 0.06 5/ie "/3z "/sz 1/2 x 1/4 x 3/8 �.�6 SII6 5�8 9I16 Continues... Consul[price sheet for Made to Order items and for minimum order quantities. NIBCO INC.WORLD HEADQUARTERS•1516 MIDDLEBURY ST.•ELKHART,IN 46516-4740•USA•PH 1.800.234.0227 m TECH SERVICES PH:1.868.446.4226•FAX:1.800.234.0557•INTERNATIONAL SERVICE PH:.1.574.295.3221 •FAX:t7.574.295.3455 www.nibco.com _ ... . . • � • � - � ELBOWS continued �.� , � � � �� � � � '� b.� -_.� - �- -- � I-- I- _I 1�-D-'1 707 607-LT 90° Elbow - Close Rough 90° Elbow - Long Radius CxC - Cast CxC �- V',1rot •� � � � �� � �� � � � 11/4x1 G-�� 1� ; 3,�1�UL` � __- _ ______ _ __ 1 1/4 x 3/4 0.34 `'/�6 "he I 1/8 0.01 ''/3� � 13/3: � 1 1/4 x 1/2 �.ZB 15�32 Z��32 5/16 O.D. 0.02 9I16 9I16 � 1 1/2 x 1 0.54 ��/is 1 1/4 0.02 '�/az ��/az � 1 1/2 x 3/4 �.42 19I32 3�I32 ��Q X��8 �.�� �9�32 ��2 1 1/2 x 1/2 0.40 5/a Z9/sz 3/8 0.04 Z�/az z3/32 I 2 x 1 1/4 0.86 '/a 1'/4 1/2 0.08 '/a '/a o t-- 2 x 1 OJ8 3/a 1�/a 1/2 x 3/8 0.06 13I16 13hc 2 x 3/4 0.69 5�8 ���4 ��21(��Q �.�3 ZSI32 Z��32 6�� 21/2 x 2 2.16 �3�16 19/az 5/8 0.10 13/3z 13/sz 9�° Elbow- CloseRough 3x21/2 2.26 1'�/ie 1�/z 5/8x1/2 0.09 1'/ie 1'/i6 C X C - WfOt 3 x 2 2.68 13/s �yll6 3/4 0.16 1'/s 1'/a 4 x 3 5.18 �29�32 215/3z 3/4 x 5/8 0.13 1'/a 13/3z � � � � � 3/4 x 1/2 0.10 1'/e 1'he 1/8 0 01 "/, ''L�� � � 7/8 0.28 119/3z 119/3i ��4.__. _- _---�.�2___-_--9�32 -..._9�32 � �.28 ���i6 ���16 3/8 0.03 'h '/z � 1 x 3/4 0.20 1'/a 1�/e ��Z �.�4 3�8 3�8 .������ r- - � �X 5�8 �.�5 �13I32 �3I32 1/2 x 3/8 0.04 9I16 Z�/3z � � �- 1 1/4 0.42 1'/e 1�/e 3/4 0.10 ��hz 17/az �p 1 1/4 x 1 0.33 �ZSI32 1'/z 3/4 x 5/S 0.12 29I32 �/e 1 1/2 0.66 2�/a 2'/s 3/4 x 1/2 0.10 ��/3z 3/n 2 1.23 Z�SIl6 215/ie � 0.21 23�32 Z3/32 6Q7'I 2��Z 1.96 3���16 3���16 1 x 3/4 0.16 23I32 5/e 9�° Elbow - s 2.93 4'/3z 4'/3z 11/4 0.31 1'/3z 1'/3z Intermediate Radius C x C - Wrot ! 4 5.95 5'/d 5'/4 1 1/4 x 1 0.31 15/e 115/az ��� � � � 1 1/2 0.46 1�/sz 1�/sz � I 1 1/2 x 1 1/4 0.35 15/sz 13/az 1/2 ____ 0.06 14/��_ '�/sz i 2 0.84 1'/z 1'h 5/8 0.09 '/e '/a � 2 x 1 1/2 0.58 1'/ic 1'/a 3/4 0.14 13/,e ''/ie 21/2 1.41 127/3z 127lsz 1 0.24 1'hs 1'hs 3 2.�� Z3I32 Z3I32 3��2 2.94 Z3I8 23�8 4 4.23 ZZ5�32 225�32 5 7.J4 2'IB Z'IB 6 10.95 3'hs 3'/,e S 29.50 423I32 4z3/3z Consult price sheet for Made to Order items and for minimum order quantities. m NIBCO INC.WORLD HEADQUARTFRS•1516 MIDDLEBURY ST.•ELKHART.IN 46516-4140•USA•PH:1.800.234.0227 TECH$ERVICE$PH:1.888.446.4226•FAX:1.800.234.0557•INTERNATIONAL SERVICE PH:-1.574.295.3221 •FAX:r1.574.295.3455 www.nibco.com �' 4700 W.1601h St. � a e Cleveland, OH 44135 PN:800-321-9532 STANDARD PIPE CLAMPS �$��1� FX:800-321-9535 --� www.oatey.com TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION: Oatey Standard Pipe Clamps provide fast and easy installation of all types of copper tube sized and drain,waste and vent sized piping. Standard Pipe Clamps are designed to permit quick pipe cooling and reduce water noise. The design allows the piping to be flush mounted to the wall and joists. Standard Pipe Clamps can be used with hydronic heating systems. ° , APPROVALS AND LISTINGS � , ��.+ ��� i,'� �� �', .. � �,• IAPMO Listed �:���;. .,�;����.;��� .�r,.�lr�� ��-.. PHYSICAL/CHEMICAL PROPERTIES Material Polypropylene Color Gray DIRECTIONS FOR USE Open clamp and snap over pipe or tube. Slide into position and secure with barbed nail or screw. Check with local codes to ensure proper spacing requirements for piping support. NOTE: When using with DWV or Galvanized piping, use the next larger clamp size than the pipe. PRECAUTIONS Read cautions and directions on packaging carefully before using this product. KEEP OUT OF REACH OF CHILDREN. COMMON APPLICATIONS Standard Pipe Clamps provide fast and easy installation and support for all types of piping. Consult Oatey Technical Department for applications not specifically referenced above. PRODUCT NUMBER DESCRIPTION PACK CARTON WEIGHT 33916 '/z"Standard Pi e Clam 6 er ba 6 ba s 2 Ibs. 33940 '/z"Standard Pi e Clam 100 er ba 500 5 Ibs. 33917 3/a"Standard Pi e Clam 6 er ba 6 ba s 2 Ibs. 33941 3/a"Standard Pi e Clam 100 er ba 500 6 Ibs. 33877 1"Standard Pi e Clam 6 er ba 6 ba s 4 Ibs. an ar i e am er a s. 33943 1-Ya' Standard Pi e C am 25 er ba 250 4 s. 33944 1-�/z"Standard Pi Clam 25 er ba 250 10 Ibs. 33946 2"Standard Pi e Clam 25 er ba 250 13 Ibs. F-16 Visit www.oatey.com for updates 10/2005 � 4700 W.1601h St. . , � a e Cleveland, OH 44135 SUSPENSION PIPE CLAMPS PH:800-321-9532 �SQ 9��7� FX:800-321•9535 —�,R'w!1}7'r www.oatey.com \�'�% TFCHNICILL SPECIFICATION `�� TECHNICAL SPECIFICATION:Oatey Suspension Pipe Clamps provide fast and easy installation and support and can be used as an insulator when running water distribution lines through wooden framing. Suspension Pipe Clamps can be used with hydronic heating systems. APPROVALS AND LISTINGS , : i>:' • I +, IAPMO Listed r' K ` �` - � �`° � � L J , � � � 1 PHYSICAL/CHEMICAL PROPERTIES Material Polypropylene Plastic Color Gray DIRECTIONS FOR USE Open clamp and snap over pipe or tube. Slide into position and secure with barbed nail or screw. Check with local codes to ensure proper spacing requirements for piping support. PRECAUTIONS Read cautions and directions on packaging carefully before using this product. KEEP OUT OF REACH OF CHILDREN. COMMON APPLICATIONS Oatey Suspension Pipe Clamps provide fast and easy installation and support for all types of copper tube sized piping. Consult Oatey Technical Department for applications not specifically referenced above. PRODUCT NUMBER DESCRIPTION PACK CARTON WEIGHT 33914 '/z"Sus ension Clam 6 er ba 6 ba s 4 Ibs. 33935 '/2"Sus ension Clam 100 er ba 500 5 Ibs. 33915 3/a"Sus ension Clam 6 er ba 6 ba s 4 Ibs. 33936 3/a"Sus ension Clam 100 er ba 500 7 Ibs. 33937 1"Sus ension Clam 50 er ba 250 4 Ibs. 33956 1-�/a"Sus ension Clam Z5 er ba 250 4 Ibs. 33957 1-�/z"Sus ension Clam 25 er ba 250 4 Ibs. 33958 2"Sus ension Clam 25 er ba 250 5 Ibs. F-18 Visit www.oatev.com for updates 10/2005 �� • ■ . . . _ � Fig. 100 - All Thread Rod Full Lengths Size Range Material � � '"'!,�;. Maximum Temperature ,,,;, Finish ��;;. Note l����;��%� �. �,�;,: Order y ��% ��/ ,,. � >' '"�((((/��j., ,4�� Dimensions •Weights ,, � Max Rec.Load Lbs. Rod For Servlce Temps Approx. Slze 650 F 50 F Wt. 100 OFfICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX� 951.737.0330 � CUSTOMER SERVICE•800.186.5266 www.tolco.com V V � � — - � . ��. Fig. 202 - Adjustable Epoxy Copper TecT"" Tubing Ring Hanger Size Range— 112" thru 6" copper tubing ::__� Material—Carbon Steel i Function— Recommended for the suspension of non- insulated stationary copper tubing. �� Approvals—Conforms to Federal Specification C WW-H-171 E,Type 10, 1/2" thru 4", and Manufacturers �-�— Standardization Society SP-69,Type 10 � Finish— Epoxy Copper TecT"" Plated i� Order By— Figure number and nominal tubing size �� ; �. , B �,. � A Dimensions •Weights Pipe Rod Size Max.Rec. Approx. Size Rod Size A B C Load Lbs. Wt./100 1/2 3/8 3�/e 2�a 1 Vz 400 11 3/4 3/8 3�/a 25/s 1�/a 400 11 1 3/8 3�/a 2�/2 1 400 12 1 Va 3/8 3�/a 2�/z 1 400 13 2 e a 2 3/8 4�/x 3�'e 1�/z 400 15 2�/z 3/8' 5Yz 4�'a 2 600 40 3 1/2 63�8 4�a 2 600 45 3�/z 1/2 F)3�8 4�/z 1 Yz 600 52 4 1/2' 73/s 5'/a 2 1250 59 5 5/8 83/e 5�a 2 1250 97 6 5/8 9�/z 6�'s 1�/e 1250 139 ' 2'/z"CT filled with water weighs less than 2"IP filled with water,4"CT less than 3'h"IP with water. 2'h"CT available with 1/2"thread and 4"CT available with 5/8"thread tor Government Specs. OFFICElMANUFACTURING FACILfTY•1375 SAMPSON AVE.•CORONA,CA 92679•PH 951 J37 5599•FAX 951 J37.0330 m CUSTOMER SERVICE•800 786 5266 � www.tolco.com