Loading...
HomeMy WebLinkAboutF13-0054 stamped approved ❑ o 0 0 ❑ o ❑ o 0 FIRE SPRINKLER RISER � O � .�., t' ❑ �°� �,��0 ��T F.D.0 � �F �o' � i 2y2X2+z � � HORN7STRaBE 2� / ' . .G. �s / �,� / / NOT LESS THAN 1'/:"UP TO 3'f�'PIPE GATE VA �,� NOT LESS THAN 3"FOR 4&5"PIPE HARDENED HEX HEAD SELF THREADING SCREW � �� �� IS FURNISHED WITH THE HANGER AND IS THE � , � MINIMUM FASTENER SIZEACCEPTABLE � O ,� ♦ / WOOD SAMM ,, TEST SIDEWINDER MIN.2'/i'FROM BOTTOM FOR LINES MIN.3"FROM BOTTOM FOR MAINS � FIRE HYDRANT THIS DOES NOTAPPLY TO 2"NAILER /_AP�� ELEV. 8157 ALL THREAD ROD STRIPS RESTING ON TOP OF BEAMS / ���,�- WOOD I WOOD � '� HYDRANT FLOW TEST ADJUSTABLE BAND Oj P G� TEST DATE: 04/20/2012 HANGER RING � P�� PROVIDED BY: VAI L VALLEY FIRE SPRINKLER CO OR TJI'S,CONSULT TRUSS MANUFACTURE `FOR COPPER&CPVC PIPE• ANTI-FREEZE N�TES � GJ� STATIC PSI: 135 FOR RECOMMENDED INSTALLATION POINT � t,�� RESIDUAL PSI: 125 x x ANTIFREEZE SYSTEM VOLUME IS 57 GAL. OW��D SAMNIY SIDEWINDER OD�UBLE FASTENER STRAP PITOT PSI: 60 FP-1 SCALE:NOTTOSCALE FP-1 SCALE:NOTTOSCALE ANTIFREEZE SYSTEM VOLUME SUBJECT TO � OLJTLET SIZE: 2'/z TEMPERATURE FLUCTUATIONS IS 20 GAL. / FLOW GPM: 1300 38°� PROPYLENE GLYCOL SOLUTION I HYDRANT FLOW TEST PRESSURES REDUCED TARGET LOW TEMPERATURE PROTECTION 0°F BY 1U% PRIOR TO CALCULATIONS FREEZE PR�TECTION BELOW 0°F IS THE � RESPONSIBILITY OF THE GENERAL CONTRACTOR. � pC � MINIMUM DISTANCES FOR RESIDENTIAL SPRINKLERS [13D; TABLE 7.5.5.3] RISER LEGEND a a MINIUMUM MINIMUM 1. 2"WATER SUPPLY FROM CITY MAIN O DISTANCE FROM DISTANCE FROM 2. 2" pRESSURE REDUCER U 2 S ITE PLAN EDGE OF SOURCE EDGE OF SOURCE = TO ORDINARY TO INTERMEDIATE 3. PRESSURE GAUGE � TEMPERATURE TEMPERATURE 4. 2�� FEBCO 860 RP BACKFLaW W/TAMPERS 13 N FP1 NO SCALE HEAT SOURCE SPRINKLER{IN.) SPRINKLER{IN.} 5. WATER FLOW DETECTOR SIDE OF OPEN OR RECESSED FIREPLACE 36 12 6. 1�� TEST AND DRAIN FRONT aF RECESSED FIREPLACE 60 36 7. 1'/z" CHECK VALVE COAL OR WOOD-BURNING STOVE 42 12 8. 6.4 GALLON A/F EXPANSION CHAMBER W/PRV - KITCHEN RANGE 18 9 9. 1" GLOBE VALVE FOR SYSTEM FILL/DRAIN � WALLOVEN 18 9 10. AIR GAP DRAIN HOTAIR FLUES 18 9 11. 1" CHECK VALVE HYDRANT FLOW TEST PRESSURES REDUCED UNINSULATED HEAT DUCTS 18 9 12. 1" MAIN DRAIN/TEST DISCHARGE BY 10% PRIDR TO CALCULATIONS UNINSULATED HOT WATER PIPES 12 6 13. SPARE HEAD BOX(6} SIDE OF CEILING OR WALL-MOUNT HOTAIR DIFFUSERS 24 12 14. 2" BUTTERBALL VALVE Hydraulic Information FRONT OF WALL-MOUNT HOTAIR REGISTERS 36 18 3 Remote Area 1 HOT WATER HEATER OR FURNACE 6 3 4 t, �� OCCUPANCY CLASSIFICATION Residential LIGHT FIXTURE{0-250 WATT) 6 3 DENSITY 0.100 m/ft for 356.12f�{Actual 356.12ftr} LIGHT FIXTURE{250-499 WATT) 12 6 2'-0" A.F.F. __�- ` � 1'/z' COPPER � 4r--- , �.--,? , TOTAL HOSE STREAMS 100.00 TOTAL HEADS FL�WING 2 { -� W i1 3 �. a 14 � K-FACTOR 4.9 � � 1p _ 7 � g TOTAL WATER REQUIRED 165.41 c� _. b � -o TOTAL PRESSURE REQUIRED 95.899 ' BASE of RISER { m} 65.41 N � �� 6 BASE of RISER { si 73.316 12 SAFETY MARGIN ( si) +25.403 (20.9°�} ELEV. 8135' � o � , n . _ ' Z Q CALC #1 � m � '$ � a �� � � � � � .� o ET ¢� 3 SYSTEM RISER 8-6 8-5 3-�0 ¢11 211 � � F P� Na SCALE BEDR � OM 4 1 9'-6°c��. �o� � ��7 B E D R � O M 6 ��N � � 9'-6"CLG. � �' 1 � s �� _��1 � � � �.�f�JV � � � r�� � ��1 � �' � � T � � � � a� � r MEDIA / SITTING RD � M � 9'6"CLG. ] � � � Ij z °f 2 r ' 'j � m � - • � 0 6-10 FP1 �. � � �_� �� ;,�; <i 0 .�O � � � r.r ° � � � � � 3 GENERAL N�TES � • � �prl.�`l 11 8 • � � • 6 �`� �� THIS WET PIPE SPRINKLER SYSTEM DESIGNED TO COMPLY WITH NFPA 13R,AND OTHER APPLICABLE STANDARDS,AND TO BE APPROVED � ,� r O � ,� ' ,�O� a JQ BY THE LOCALAUTHORITIES HAVING JURISDICTION PRIOR TO COMMENCEMENT OF FABRICATION AND INSTALLATION. � 4-3 1=2 � E � �. �o- � � � � � � � M r'�p � � 4 FREEZE PROTECTION BELOW O�F IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR/OWNER. � �' �f=i I Fa9 O'7 � ' � � r . � , ��°� �1 �, , ;, r,� >> I'� r � O T _ � � r SEEATTACHED'EQUIPMENT DATASUBMITTAL'FORALLAPPLICABLE MATERIALSAND EQUIPMENT USED ON THIS PROJECT. � � 9-6"CLG.� � �� �ya —, r , O � � � � � � �j . ALL PIPING TO BY COPPER TYPE'M'UNLESS OTHERWISE NOTED. ��Ia 8'-B"CLG. r U �`' N � � �Is 1'/a 1'/s 1�� r / � � 1'/s � 1� � 1'/s 1'/� 1'/� 0-5 1'/s 1'/s 1'/� 1'/� 15-0 2-6 4-4 0 ,�1-���� 10-0 I 2-0 12-8 2-6 7-6 �� 4-10 2-0 � � 4-11 10 ALL PIPE DIMENSIONSARE CENTER TO CENTER. � � 0 � <;, 'I U IN � � � 7 �� � PIPE HANGERS SHALL COMPLY WITH NFPA 13R STANDARDS.SEE PLAN FOR DETAILS AND LOCATIONS. � � � ;_8°° g�_g�� � r � �,`�, T �d G°; � f� � SPRINKLERS TO BE INSTALLED IN ACCORDANCE WITH NFPA 13R,THEIR LISTINGS,AND PER THE LOCALAHJ. � �� i LE SHOWER �. . \ � LG. � CLG. ' EXERCI � � � �'�f! �J � 9'-n" PROJECT SPECIFICATIONS WERE NOT PROVIDED TO THE INSTALLING CONTRACTOR FOR REVIEW. THEREFORE THE PRODUCT IS � � � `_-"�-�� I I pp I I 'I CONSIDERED DESIGN BUILD. THE INSTALLING CONTRACTOR HAS UTILIZED SYSTEM MATERIALSAND STANDARDS THATARE � ' CONSIDERED INDUSTRY STANDARD AND APPROPRIATE FOR THE TYPE OF BUILDING AND EXISTING CONDITIONS. � ������ - � , ti BENCH 'I O-7 'I �2 1�/ � TILE SHOVI r � T' � I ��` '' � /� "' � " � 6•4 �-�� THE OWNER SHALL MAINTAIN A CLEAR 1 B"BETWEEN THE CEILING AND THE TOP OF ANY STORAGE OR OTHER OBSTRUCTIONS. � � � � a r � 79 �'�� 2��� � 7-9 � � H A L L 7 6 � ANYACCESS PANELS FOR VALVEAND DEVICEACCESSIBILITY IS TO BE BY OTHERS. +� � � — c�'b � � � g�_6� � � �I j THE OWNER IS RESPONSIBLE FOR ANNUAL INSPECTIONS,TESTING,AND MAINTENANCE PERFORMED BYA LICENSED CONTRACTOR AS �� � � REQUIREDBYNFPA25. � 6�� 8�_8�� ,�\'� � • �� _ 3-5 � � 2-1 � 0-9 � �= LG. CLG. JQ g,_6„ 8,_s„ 15-10 a_a � � - IF FIELD CONDITIONS RESULT INACHANGE TO THE SHOP DRAWING INSTALLATION INANY WAY,CONTACT THE PROJECT DESIGNER TO C LC. CLG. � � � � 8-8 9-6 VERIFY PROPOSED CHANGES ARE COMPLIANT WITH NFPA 13R REQUIREMENTS AND PER HYDRAULIC DESIGN. 7 11 � � � � � CLG. CLG. � �`''� � ``' � � � ALL BATHROOMS TO HAVE NON-COMBUSTIBLE FIXTURES,WALLS,AND CEILINGS. ALL BATHROOMS UNDER 55 SQ FT DO NOT REQUIRE 7_$ � � 4�8 � � r � SPRINKLERS.NFPA DEFINES BATHROOMS AS ANY ROOM OR COMPARTMENT WITHIN A DWELLING UNIT CONTAINING A LAVATORY 9'-6"CLG. � � i_,� i � DEDICATED TO PERSONAL HYGIENE,OR A WATER CLOSET,OR BATHING CAPABILITY SUCH AS A SHOWER OR TUB,OR ANY COMBINATION � I � r�� OF FACILITIES THEREOF. 7� P � W � E � • ~ MASSAGE � ��� O T O ALL CLOSETS UNDER 24 SQ FT WITH THE LEAST DIMENSION UNDER 36"DO NOT REQUIRE SPRINKLERS. UTILITYAND LAUNDRY CLOSETS ' � _ � � 9'-6"CLG. 1 . Oftz M SHALL HAVE SPRINKLERS INSTALLED. ELEV. �LAUNDRY � � � � ALL PIPE TO BE RUN CONCEALEDABOVE CEILINGS IN FINISHEDAREAS. ' 9'-6"CLG. �� 1h� 3-�1 PENDENT SPRWKLERS IN CEILINGSARE TO BEALIGNED WITH CEILING FIXTURES WHERE POSSIBLEAND REASONABLE. •�� � � '—' 1-2 � � ,r� �, Q�r��..�-�i 1 3-5 $_9 �a i � r"-,e�iV '-O ENSUREALL PIPING ISADEQUATELY DRAINABLE EVEN IFALL DRAINSARE NOT SHOWN ON THIS PLAN. 1-0 B � '� �; � 88 �. 8�-8��CLG� TILE SHOWER B A T�H 7 � � HYDRAULIC DESIGN NOTES � = THE ENTIRE SYSTEM IS SIZED BASED ON HYDRAULIC CALCULATIONS.ADEQUATE CALCULATIONS HAVE BEEN CONDUCTED TO MAKE Z BENCH ASSUMPTIONS FOR ENTIRE PROJECT. w 9'-6"CLG. m DESIGN OF RESIDENTIALAREAS IS IN ACCORDANCE WITH RESIDENTIAL CRITERIAOF NFPA 13R AND VAIL FIRE DEPARTMENT REQUIREMENTS. THE DESIGN AREA CONSISTS OF THE 4 MOST HYDRAULICALLY DEMANDING SPRINKLERS WITHIN A SINGLE COMPARTMENT AS SPECIFIED BY THE AHJ.MINIMUM DISCHARGE AT EACH SPRINKLER IS 0.10 GPM.THE AREA PER SPRINKLER CALCULATED FOR THIS PROJECT IS 196 SQ FT FOR COMPARTMENTS WITH 4 OR MORE SPRINKLER HEADSAND 256 SQ FT FOR COMPARTMENTS WITH 3 SPRINKLER HEADS AND 324 SQ FT FOR COMPARTMENTS WITH 2 OR LESS SPRINKLER HEADS.THE EXCEPTION IS CALCULATION#2 WHICH PROVES 256 SQ FT SPACING FOR THE SECOND FLOOR.NO SPRINKLER MAY BE MORE THAN 9'FROM AN ADJAGENT WALL OR 18'FROMANADJACENT SPRINKLER INANY COMPARTMENT CONTAINING MORE THAN 1 SPRINKLER.100 GPM HOSE ALLOWANCE HAS BEENADDED FOR DOMESTIC WATER FIXTURES. � F I RS T F L��R F I R E S P R I N KL E R P LAN A DETAILED HYDRAULIC INFORMATION BOX HAS BEEN PLACED BY EACH CALCULATION ON THE DRAWINGS. WATER FLOW TEST RESULTS WERE REDUCED BY 10°�PRIOR TO HYDRAULIC CALCULATIONS. N FP� 1/4"= 1 '-0" SQ.FT.= 2,807 1 3 5 7 9 2 4 6 8 10 PROJECT: SYMBOL LEGEND COPPER TUBE HANGER SPACING OVER 100 PSI SPRINKLER LEGEND ���� ������ 625 FOREST R�AD S.R.R. =SMALL ROOM RULE O =HY�RAULIC NODE TAG SIZE BETWEEN HANGERS TO END OF LINE ARM-OVER LENGTH MAX. SYMOBOL M Co S2N# Q 9Y K P nP Et R�ESP SIZE FVNISH T 6�F CONCEALED NorE ^ fi25 FOREST RDAD O.T.S. =OPEN TO STRUCTURE =TYPE M COPPER PIPE 3/4" 8'-0" (SSP)0'-6" (SSU)1'-0" (SSP)0'-6" (SSU)1'-0" TYCO TY2234 1 4.9 Pendent Quick '/�" White 175°F RECessE� F P � FIRE PROTECTION DESIGN, �NC. ���� ��������� VAIL, COLORADD 81 fi57 Up =PIPE DIRECTION UP =THREADED STEEL PIPE ��� 8�-0" (SSP)0'-6" (SSU)1'-6" (SSP)0'-6" (SSU)1'-0" Total=30 13147 BIRCH wAY,THORNTON,Co 80241 (303)920-0941 � =PIPE HANGER GORPORATION FIRE SPRINKLER PLAN � -WEL�ED STEEL PIPE ��4� 10'-0° (SSP)0'-6° (SSU)2'-0° (SSP)0'-6° (SSU)1'-0" PAUL D.HUBBARD� NICET III�#108221 � Dn =PIPE DIRECTION DOWN � ��. F 1%i' 10'-0" (SSP)0'-6" (SSU)2'-6" (SSP)0'-6" (SSU)1'-0" �`� �-�" FI RST FLOOR ,Q BL1 =BRANCH LINE#1 ��� 1,� ,��,; _• Rn =PIPE RISER NIPPLE g� =CENTER LINE PIPE ELEVATION �� =MAIN#1 2" 12'-0° (SSP)0'-6° (SSU)2'-6" (SSP)0'-6° (SSU)1'-0" DRAWN BY: SCALE: A.H.J. * PAUL D. HUBBARD AS NOTED VAIL FIRE OH1 =ORDINARY GROUP 1 HAZAR� ABOVE FINISHED FLOOR A =GROOVED PIPE SEGMENT 2%z' 12'-0° (SSP)0'-6° (SSU)2'-6° (SSP)0'-6° (SSU)1'-0" 57 HEREFORD LANE EDWARDS GOLORADO S i 632 CONTRACT#: �ATE: DRAWING NUMBER: 3" 12'-0" (SSP)0'-6" (SSU)2'-6" (SSP)0'-6" (SSU)1'-0" 1311�2 121�3113 FPi OF 3 MINIMUM DISTANCES FOR RESIDENTIAL SPRINKLERS [13D; TABLE 7.5.5.3] MINIUMUM MINIMUM DISTANCE FROM DISTANCE FROM EDGE OF SOURCE EDGE OF SOURCE TO ORDINARY TO INTERMEDIATE TEMPERATURE TEMPERATURE HEAT SOURCE SPRINKLER{IN.} SPRINKLER{IN.) EL:8175'-3" SIDE OF OPEN OR RECESSED FIREPLACE 36 12 FRONT OF RECESSED FIREPLACE 60 36 CDAL OR WOOD-BURNING STOVE 42 12 KITCHEN RANGE 18 9 WALL OVEN 18 9 HOTAIR FLUES 18 9 UNINSULATED HEAT DUCTS 18 9 UNINSULATED HOT WATER PIPES 12 6 SIDE OF CEILING OR WALL-MOUNT HOTAIR DIFFUSERS 24 12 FRONT OF WALL-MOUNT HOTAIR REGISTERS 36 18 HOT WATER HEATER OR FURNACE 6 3 LIGHT FIXTURE{0-250 WATT} 6 3 LIGHT FIXTURE{25D-499 WATT} 12 6 I PANTRY GREAT ROOM �� NOT LESS THAN 1'/z'UP TO 3Yz'PIPE D I N I N G R � O M NOT LESS THAN 3"FOR 4&5"PIPE HARDENED HEX HEAD SELF THREADING SCREW ♦� IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE WOOD SAMM MIN.2'/z'FROM BOTTOM FOR LINES EL: 8158�-0�� SIDEWINDER MIN.3"FROM BOTTOM FOR MAINS THIS DOES NOTAPPLY TO 2"NAILER ALL THREAD ROD STRIPS RESTING ON TOP OF BEAMS WOOD WOOD _ O ADJUSTABLE BAND � HANGER RING OR TJI'S,CONSULT TRUSS MANUFACTURE 'FOR COPPER&CPVC PIPE` FOR RECOMMENDED INSTALLATION POINT eWO�D SAMMY SIDEWINDER e D�UBLE FASTENER STRAP FP-1 SCALE:NOT TO SCALE FP-1 SCALE:NOT TO SCALE SKI J MUD ROOM FAMILY RODM GAME EL: 8146'-6" HYDRANT FLOW TEST PRESSURES REDUCED BY 1 U% PRI�R TD CALCULATIONS Hydraulic Information Remote Area 2 �CCUPANCY CLASSIFICATION Residential ��` DENSITY 0.100 m/ft for 640.33ftz Actual 640.33ftZ) I L A U N D R Y B A T H 6 B E D R O O IVl 6 TOTAL HOSE STREAMS 100.00 i TOTAL HEADS FLOWING 4 B U N K R O O M K-FACTOR 4.9 TOTAL WATER REQUIRED 203.31 D E C K TOTAL PRESSURE REQUIRED 108.867 BASE of RISER { m) 103.31 BASE of RISER { si 76.633 D E C K SAFETY MARGIN { si} +12.343 (10.2°� EL: 8135'-6" � HOT TUB � Z DECK ° � �ROSS sECTiaN > FP2 1/4"= 1 '-0" 1 1 �� 3 I I � � � � � I 9 I I � 2 1 4 6 � 10 ,,,,;,v,-,;,�,; ) r , � � � � CALC #2 FA Y ROOM ' "' ,� 9-1 -- -� � � �5 � � 0 � wmi:_ �"8-0 � ,v � � U1 2-10 � n ;_r��c�G � 13 °° �� 5-'! ll �� 7-11 �j 8-0 8-0 8-0 B A R c.� � S�O _� 9'-0"CLG. � � � BEDROOM 2 � � � � � � 0 1 �� 9�_6��c��. �� S I T T I N G N N Da .1 0 9-3 � � �'� r iJ��.l � � � � OG BEti�i�.�0 Q � p w G I / � m LOG BEAM � � ° M E 14 '��� i/ 03 � � � 04 � �+,� / � � � �� � � � 2 U �7 ° � O0 ,�� 'j \ 00 + � � � �� � � '����'� GENERAL N�TES s-s , �. � M <[�1 °' ,�± � �A T H 2 � N � � � THIS WET PIPE SPRINKLER SYSTEM DESIGNED TO COMPLY WITH NFPA 13R,AND OTHER APPLICABLE STANDARDS,AND TO BE APPROVED � I� �\� 'I��s 'I��s �� �p 7 'I��a � 1'/a �a � � ���a I�I � 1'/a � 'I��a � 'I��a Q� BY THE LOCALAUTHORITIES HAVING JURISDICTION PRIOR TO COMMENCEMENT OF FABRICATION AND INSTALLATION. � � T� � � 3- �% 3-$ �'2 � �� N 9'�LINEN � � g�� �-� �6-O �-� 5�5 ���� FREEZE PROTECTION BELOW O�F IS THE RESPONSIBILITY OF THE GENERAL CONTRACTORIOWNER. 9'-6"CLG r O �<� pp � r � . ❑ �� °•,G N � ' 2� I� �9 I ,�g �6 SEE ATTACHED'EQUIPMENT DATA SUBMITTAL'FOR ALLAPPLICABLE MATERIALS AND EQUIPMENT USED ON THIS PROJECT. � � _, � � � � rj — ALL PIPING TO BY COPPER TYPE'M'UNLESS OTHERWISE NOTED. . . ��". r �, �G�� I[� r,� � ALL PIPE DIMENSIONSARE CENTER TO CENTER. ���� � � 4- `-_' � � � � � ¢�,� � PIPE HANGERS SHALL COMPLY WITH NFPA 13R STANDARDS.SEE PLAN FOR DETAILS AND LOCATIONS. � � 8'-8"CLG. � $"1� � �� ' � C'� SPRINKLERS TO 8E INSTALLED INACCORDANCE WITH NFPA 13R,THEIR LISTINGS,AND PER THE LOCALAHJ. �� � �� � r — �+�' ; - r �� � � 'I 'I ,� PROJECT SPECIFICATIONS WERE NOT PROVIDED TO THE INSTALLING CONTRACTOR FOR REVIEW. THEREFORE THE PRODUCT IS DN �I R � � CONSIDERED DESIGN BUILD. THE INSTALLING CONTRACTOR HAS UTILIZED SYSTEM MATERIALSAND STANDARDS THATARE � ♦ � � r'� ,� , ���.I :�r� 5'9 1�'8 �`> �/ 22 \ r � � �� � CONSIDERED INDUSTRY STANDARD AND APPROPRIATE FOR THE TYPE OF BUILDING AND EXISTING CONDITIONS. � � rN , m � � 0�1 Q� ���s I ���� � �` � r _ � _, � - s.Q THE OWNER SHALL MAINTAIN A CLEAR 1 B"BETWEEN THE CEILING AND THE TOP OF ANY STORAGE OR OTHER OBSTRUCTIONS. ��1 � � u z . . . .�. �:rl�� �� .,_ � �� � = I .. � �" _ a� ° � :i� �"�.;�, e � � 2-�Q —$� 'I-2S II - � � �� " � V `� `°I ` L° v ��� O O O O E . ANYACCESS PANELS FOR VALVEAND DEVICEACCESSIBILITY IS TO BE BY OTHERS. � �$ ���,•� �° U�' �-6 CLt, ?�-E _"_ 4i �i ���� 24 ' � � �I�y °' U �j n � THE OWNER IS RESPONSIBLE FOR ANNUAL INSPECTIONS,TESTING,AND MAINTENANCE PERFORMED BYA LICENSED CONTRACTOR AS � \ �� � 1 6-�I �� � � �, 1 REQUIRED BYNFPA25. �'4 I��� 6-O � � � � �� �� IF FIELD CONDITIONS RESULT INACHANGE TO THE SHOP DRAWING INSTALLATION INANY WAY,CONTACT THE PROJECT DESIGNER TO ��� 3 �� ��7 � ��� '� ��8 � VERIFY PROPOSED CHANGES ARE COMPLIANT WITH NFPA 13R REQUIREMENTS AND PER HYDRAULIC DESIGN. �� ���� � � � � N � � ALL BATHROOMS TO HAVE NON-COMBUSTIBLE FIXTURES,WALLS,AND CEILINGS. ALL BATHROOMS UNDER 55 SQ FT DO NOT REQUIRE 9'-6"CLG. +� 23 o O fY�l P � W D R • SPRINKLERS.NFPA DEFINES BATHROOMS AS ANY ROOM OR COMPARTMENT WITHIN A DWELLING UNIT CONTAINING A LAVATORY �`> � � � � � } ��� E L E V. � � � DEDICATED TO PERSONAL HYGIENE,OR A WATER CLOSET,OR BATHING CAPABILITY SUCH AS A SHOWER OR TUB,OR ANY COMBINATION 5-11 � z � OF FACILITIES THEREOF. J4 o T RAS H ALL CLOSETS UNDER 24 SQ FT WITH THE LEAST DIMENSION UNDER 36"DO NOT REQUIRE SPRINKLERS. UTILITYAND LAUNDRY CLOSETS � 1 1 a°� C A R G A G SHALL HAVE SPRINKLERS INSTALLED. rJ-9 � 13-H � ALL PIPE TO BE RUN CONCEALEDABOVE CEILINGS IN FINISHEDAREAS. B E D R Q C} ''�" �� � PENDENT SPRWKLERS IN CEILINGSARE TO BEALIGNED WITH CEILING FIXTURES WHERE POSSIBLEAND REASONABLE. 9'-6"CLG. \ � ENSUREALL PIPING ISADEQUATELY DRAINABLE EVEN IFALL DRAINSARE NOT SHOWN ON THIS PLAN. � � CHECK VALVE � I 1 e� � a �,, '` ��y, '� HYDRAULIC DESIGN NOTES � �O�d.� THE ENTIRE SYSTEM IS SIZED BASED ON HYDRAULIC CALCULATIONS.ADEQUATE CALCULATIONS HAVE BEEN CONDUCTED TO MAKE �• � t0 ASSUMPTIONS FOR ENTIRE PROJECT. �`± � I� - DESIGN OF RESIDENTIALAREAS IS IN ACCORDANCE WITH RESIDENTIAL CRITERIAOF NFPA 13R AND VAIL FIRE DEPARTMENT F.D.C. - ■ REQUIREMENTS. THE DESIGN AREA CONSISTS OF THE 4 MOST HYDRAULICALLY DEMANDING SPRINKLERS WITHIN A SINGLE O� 2��zX2��Z COMPARTMENT AS SPECIFIED BY THE AHJ.MINIMUM DISCHARGE AT EACH SPRINKLER IS 0.10 GPM.THE AREA PER SPRINKLER CALCULATED FOR THIS PROJECT IS 196 SQ FT FOR COMPARTMENTS WITH 4 OR MORE SPRINKLER HEADSAND 256 SQ FT FOR 3�-O°A.F.G. COMPARTMENTS WITH 3 SPRINKLER HEADS AND 324 SQ FT FOR COMPARTMENTS WITH 2 OR LESS SPRINKLER HEADS.THE EXCEPTION IS CALCULATION#2 WHICH PROVES 256 SQ FT SPACING FOR THE SECOND FLOOR.NO SPRINKLER MAY BE MORE THAN 9'FROM AN ADJAGENT WALL OR 18'FROMANADJACENT SPRINKLER INANY COMPARTMENT CONTAINING MORE THAN 1 SPRINKLER.100 GPM HOSE ALLOWANCE HAS BEENADDED FOR DOMESTIC WATER FIXTURES. � S E��N D F L�a R F I R E S P R I N KL E R P LAN A DETAILED HYDRAULIC INFORMATION BOX HAS BEEN PLACED BY EACH CALCULATION ON THE DRAWINGS. N F P2 WATER FLOW TEST RESULTS WERE REDUCED BY 10°�PRIOR TO HYDRAULIC CALCULATIONS. 'I/4��= 'I �-0�� 1 3 5 7 s SQ.FT.= 2,807 2 4 6 8 10 PROJECT: SYMBOL LEGEND COPPER TUBE HANGER SPACING OVER 100 PSI SPRINKLER LEGEND ���� ������ 625 FOREST R�AD S.R.R. =SMALL ROOM RULE O =HY�RAULIC NODE TAG SIZE BETWEEN HANGERS TO END OF LINE ARM-OVER LENGTH MAX. SYMOBOL M Co S2N# Q/Y K P nP Et R�ESP SIZE FVNISH T 6�F CONCEALED NOTE fi25 FOREST RDAD O.T.S. =OPEN TO STRUCTURE =TYPE M COPPER PIPE 3/4" 8'-0" (SSP)0'-6" (SSU)1'-0" (SSP)0'-6" (SSU)1'-0" TYCO TY2234 4 4.9 Pendent Quick '/�" Brass 155°F ExPOSeo F P � FIRE PROTECTION DESIGN, �NC. ���� ��������� VAIL, COLORADD 81 fi57 Up =PIPE DIRECTION UP � =THREADED STEEL PIPE ��� 8�-0" (SSP)0'-6" (SSU)1'-6" (SSP)0'-6" (SSU)1'-0" TYCO TY2334 1 4.4 Sidewall Quick '/z" White 175°F RECESSED 13147 BIRCH wAY,THORNTON,Co 80241 (303)920-0941 GORPORATION =PIPE HANGER �y;� 10'-0° (SSP)0'-6° (SSU)2'-0° (SSP)0'-6° (SSU)1'-0" Total=26 PAUL D.HUBBARD� NICET III�#108221 FI RE SPRI N KLER PLAN � =WEL�ED STEEL PIPE ` Dn =PIPE DIRECTION DOWN � ��. F 1%i' 10'-0" (SSP)0'-6" (SSU)2'-6" (SSP)0'-6" (SSU)1'-0" �"� �-�" SECOND FLOOR ,Q BL1 =BRANCH LINE#1 ��, 1, ,��„ _• Rn =PIPE RISER NIPPLE g� =CENTER LINE PIPE ELEVATION �� =MAIN#1 2" 12'-0° (SSP)0'-6° (SSU)2'-6° (SSP)0'-6° (SSU)1'-0" DRAWN BY: SCALE: A.H.J. * PAUL D. HUBBARD AS NOTED VAIL FIRE OH1 =ORDINARY GROUP 1 HAZAR� ABOVE FINISHED FLOOR A =GROOVED PIPE SEGMENT 2%z' 12'-0° (SSP)0'-6° (SSU)2'-6° (SSP)0'-6° (SSU)1'-0" 57 HEREFORD LANE EDWARDS GOLORADO S i 632 CONTRACT#: �ATE: DRAWING NUMBER: 3" 12'-0" (SSP)0'-6" (SSU)2'-6" (SSP)0'-6" (SSU)1'-0" 1311�2 121�3113 FP2 OF 3