Loading...
HomeMy WebLinkAboutB10-0089 plans ` - - _" ` �'�,41�1 1�10��S `''�////// ' �.�. � � � PUBL I C j v�-' o 0 CORRIUOR 0� DO NOt SGALE DRAWINCxS. ALL pIMENSIONS NOtED tAKE PREGEDENG� � _ 01/ER SGALED DIStANGES. � � � � 0 �����cJ 02 THE AIA DOGUMENt 201, "GENER4L CONDITIONS OF TNE GONtR4Gt FOR GON57i�l.ICTION", � � ±� ±� ARE HEREBY MADE A PARt OP tHESE CONtRACt DOGUMENtS. COPIES ARE ON FILE N N � � CLOS. AND ARE AVAILABLE FOR INSPEG710N A7 tHE OFFIGES OF THE ARCNITEGt. 00 � � � 103 0000 03 AREAS OF GON�LIGTS OR DISGREP,4NGIES MUSt BE FULL1' � � � � RE�OLI/ED WItN WRIttEN APPROVAL FROM tNE ,4RCNftEGt BEFORE � � � GONSTRUGTION GONtINUES IN tNOSE AREAS. � � 10�4 �� ii Q 0� PL,4N DIMENSIONS ARE TO �,4CE OF STUD OR F�4CE OF CONCRETE, � � �` UNLESS OtHERWISE NOTED. SEGtION AND ELEVATION DIMENSIONS ARE t0 tOP OF �p � CLOS. II 10g GONGREtE, tOP OF PLYWOOD, OR tOP OP WALL PL�4tES OR BEAMS UNL�SS � � � ,�2 II � O OtNERWISE NOtED. •— �IXED WfNpOUJ � m5 IN tHE EYENT 7NA7 ADDITION�4L DFTAILS OR CsUID,4NGE IS NEEDED BY tHE GONtR4CTOR �OR CONSTRUGtION OF ,4NY ASPECTS OF 7HIS PROJECt, tHE B�DROOM ° GONtRAGtOR SNALL IMMEDIAtELY NOtIFY tHE ARCNItEGt. �AILURE t0 CxIYE AMPLE � 10� NALL NOtIG� SN,4LL REI.IEVE ARCNItEGt OF RESPONSIBILItY. � 104 � % 06 THE CONtRAGtOR SHALL BE RESPONSIBLE �OR SATISFYINCx ALL APPLIGABLE CODES �/ OPER4BLE AND OBTAININCx ALL PERMITS AND REG2UIRED APPROY,4LS. THIS PROJEGT IS CASEMENt IUiNDOUJ �05 B.�TI-� CxOYERNED BY tNE INtERNAtION�4L SUILDINCs GODE, 20rd9 EDItION. CODE � A 10�j GOMPLIANGE IS MANDAtOR1'. tNE GONSti�I.ICTION DOCUMENt6 SNALL NOt PERMIt % WORK THAT DOES NOt CON�ORI'1 TO ,4LL REL�VANt GODES INGLUDINCs IBG �ND ALL j/ LOCAL AND RECxIONAL GODES. ����/ 07 7HE GONtRACTOR SNALL �IELD GOORDIN,4tE AND OBtAIN �,PPROYAL �ROM THE ����� - - _ _ _ = ARGHItEGt t ENCxINEER B��ORE ANY GUttINCx, NOtGNINC� OR DRILLINCx OP ANY ELEG. PANEL GASt-IN-PLACE CONGREtF, StEEI. �R4MINCs, OR ANY OtHER StRUCtUR4L ELEMENtS IUHIGH MAY A�FEGT 7HE StRIJGtUR4L INTECsRIT1' OF THE BUILDINCs. � ELEV,4T�D BUILt-INS CLOS. � �\` 0g IT IS T�4E INtENt '4ND MEANINCx OF THESE DOGUMEN7S THAT 7HE GONTR.4C70R AND U � P�4T10 ��2 O EAGN SUBCONtRAGtOR PROYIDE ALL L,4BOR, M,4TERIALS, TRANSPORTATION, I o SUPPLIES, EQIJIPMENt, EtG. t0 OBtAIN ,4 GOMPLEtE JOB WItNIN tN� REGOCxNIZED � � StANDARDS OF tH� fNDUStRY. � � 0 m9 V E R I F Y A L L D I M E N S IO N S, GO ND I t IO N S ,4 ND U t I L I tY LOG A t IO N S O N t N E JOB S I t E PR IOR U I t0 BECiINNINC� ANY WORK OR ORDERINCz ANY M�47ERIAL.B. NOTIFY ARGHITECT OF �4N1' X •� .. � CONFLIGtS OR DISGREPANGIES IN tNE DOGUMENtS IMMEDIAtELY. � p�p � � � � � 10 tHESE DOCUM�NtS ARE INtENpEp t0 INC�UDE ALI. �ABOR, MAtERI,4LS, EQUIPM�Nt AND � +' � SERvfCES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE � N •� � LIVINC-� KITCHEN I RESPONSIBILITY OF THE CONtR4CtOR t0 SRINCs t0 tHE AttENtION OF tHE ,4RCHItEGt � � � 00 EXISTING C�sAS LINE RI.JN 10� ° 106 I ANY CONDItIONS WHIGH WILL NOt PERMIt GONStRUGtION AGGORDINCx t0 tNE INtENtIONS ,4LONCx OUtSIDE SUI�AGE OF , � O� tHESF DOGUMENtS. It IS t�-IE RESPONSIBILItY OP tNE ARGHItEGt t0 PROVIpE StONE 1/FNEER _ . � DETAILS AND/OR DIREGtIONS REC�ARDINGs DESICsN INTENt WHERE It IS ALtERED 8Y ,%/,/�////,,—/ ,,,—,; /_/, _ _ — , I EXIStINC� GONDITIONS OR UJNERE NEC�LEGtED IN tHE DOGUMENtS. ' �''8`S � � 11 ANY MATERIA,LS PROPOSED �'OR SUBStItUtION OF tHOSE SPEGIFIED OR G,4LLED OUT BY ; �IREPLAGE � I tR4DE NAME IN tNESE DOGUMENtS SNALL BE PRESENtED t0 tNF ARGNIt�Gt �OR � , �, , �� ���, � REvIEW. THE CON7RAGtoR SHALL SUBMit SAMPLES WHEN REQLIIRED SY THE ARCHITEGT, W AND ALL SUCH SAMPLES SHALL BE REVIEUJED BY THE ARCHITECT BEFORE THE U10RK IS � PERFORMED. WORK MUSt CON�ORM TO THE APPROVED S,4MPLES. U10RK WHIGH DOES Q NOt CONFORM SI-EAL� BE REMOYED AND REPLAGED At tHE GONtRAGtOR'S EXPENSE. W 12 7NE BUILDINCs INSPEGTOR SHALL BE NOtIFIED SY THE CONtR4CTOR UJHEN � � N � TI-4ERE IS NEED OF INSPEGTION ,4S REQUIRED BY tHE fNtERNAtfONAL � CI' � BUILDINCx GODE OR ANY L.00AL CODE OR ORDINANGE. � � � � � � f �� f � �� �1� � 13 tNE CONtRACTOR SHALL BE RESPONSIBL� FOR tHE SA�EtI' AND C�4RE OF ,4DJACENt W } F" � �� �/��� = I�-��� PROPFRtIES DURINC� CONSTRlJC710N, FOR COMPLIANCE WItH FEDERAL AND STATE O.S.H�4. Q/ J Z O RECxULAtION9, AND FOR tNE PROTEGtION OF ALL U10RK UNtIL It IS DELIvERED PUBLIC PL�4N NOizTN GOMPLETED TO THF OWNER J � Q Q " Q RUN DUCtIUORK FOR CORRIpOR 14 t�4E CONtR4CtOR SHALL 1/ERIF1' ,4ND COORDIN,4tE ALL OPENINCxS tNROUCxH �LOORS, � � J � UJASHER/DRYER EXNAUSt tNROUCsH GEILINCsS, AND WALLS Witl-� A�� ARGHItEGtUR4L, 5tRUGTURAL, MECH�4NIGAL, PLUMBINCs, � I HR R4tED GEI�.INGrt t DEGK SOPFit 0 AND ELEGTRICAL DRAWINCsS � J ; ❑ �4801/E. FIRE-STOP PER COD�. OWN�R'S ' , 15 GONTR4GTOR t0 EMPLOY A SPEGIALIZED PIPE AND GONDUI7 PENETRATION � ' � � CLOS. SUSCONtRAGtOR t0 �IRE-StOP ALL PIPES ,4ND GONDUItS PER �IRE RESIStIVE a � 03 ASSEMBLIES PER (BC �12 O . � C��1�1�i��4� 1�10�"�S W Q J - - - - - - - - —f,. N a O10'1 II � I� 1. EXIStINCs SEPAR4tION WALLS, PARTY IUALLS, L0,4D BE�RING IUALLS � � � � II �A�s �� ,4ND GOLUI"INS, AND FLOOR/CLC�. ASSEMBLfES AS SHOUJN t0 BE 1 HR N CLOS. I �A �" �� RAtED ASSEMSLIES. ,4LL WALL t1'PES ARE t0 BE RE�ERENGED WItN t+�E � ��2 II �O g��� �p P.� RAtED ASSEMBLY SGNEDU�E I. NON-RAtED WALLS INTERSEGtINCs R4tED L— � I W� � W A LL S S H O U L D N 0 7 C O M P R O M I S E C O N T I N U O U S R,4 T E D ,4 S S E M B L I E S. Q PROYIDE 220V OUtLET t � FIXED WINDOW � WAtER HOOK-UPS �OR �ti"�V�'��'�S �r� 2. ,4LL GONStRUGtION t0 COMPLI' W/ tNE INtERNAtIONAL BUILDINCs GOD� SED�ROOM ° ���� W,4 S H E R/D R Y E R ��t�� ����—` 2 0 0 9 E D I t I O N, F O R �4 t Y P E Y-,4 R 4 t E D B L I I L D I N C� W/ F I R E S F P A R A t I O N 0 o PER REFERENCED DETAILS ON ,42. tNE EXIStINC: ,4utOMAtIG SPRINKLER 10�4 SYStEM IS TO BE MODIFIED ONLY fN ACGORDANCE U1/ SECTION 903.1.1.1 OF OPER4BLE O tHE 2009 IBC. tHE EXIStINCs EMERCsENGY VOICE/COMMUNIG,4tIONS CASEMENT WfNDOW 1m5 $,4TH DEtECtORS AND 51CsNAL DEYICES t0 BE GOORpINAtED WItN EXIStINCs A 105 FIRE PROtEGtION SYSTEM AND COORDINAtED SY FIRE PROTEGTION GONtR4GtOR FIRE ALARM DEvIGE AND SPRINKI..ER SYSTEM DR4WINCxS ISSUED FOR DATE t0 BE PROVIDED AS REQUIRED Bl' GODE OFFIGIAL FOR PERMIt. PERMIT SUBMITTAL 41410 3. ALL MODIFIGAtIONS TO EXISTINCx ELEGtRIGAL AND MECHANIGAL _ _ _ _ _ = SYStEMS TO BE IN COMPLIANGE Wlt�-1 2009 IBG MECHANfC,4L, PLUMBINC�, ELEG. PANEL ,4ND 2fd08 N,4tiON,4L ELECtRIGAL CODES. MECH,4NICAL RECxIStERS, LICxNt � FIX7LlRES, SPEAKERS, AND FIRE 51C�NAL/ALARM/pEtEGtION DEVIGES t0 BE e"-� � SURROUNDED WItH 1 HOUR PROTEC710N ASSEMBLIES PER UL C:264 �.�,�'''� ELEV.4r�p BLI11.7-INS CLOS.O \ FLOOR/CFfLINC� ASSEMBLY FOR i HOUR R4TFD CONSTRUGtION. �����;� � � � ��� P�4T10 102 B 4. PER SEGtION 3403.1 OF THE 2009 IBG, PORTIONS OF TNE StRUGTLJRE � � N07 ALtERED ARE NOT REQUIRED TO MEEt 7NE CODE REG�UIREMFNtS OF - �� .�` ��� NEW GONSTRLICTION. ANY MODIFICATIONS MADE TO THE EXISTINCx SPAGE `� id�,� ,4t ,4RE,45 IN vloLAtloN OP tNE AMERfCANS Wlt�-{ DISABILItIES ,4Gt " �' ����°�� � SHDULD BE DONE SO t0 COMPLY WItH 'ADA'. ANSI A11�.1 1998 AND tNE '���' � �'�� I AGCESSIBfLITY PORTION OF tHE 2009 IBG. �,� � �0372 LIVINC� KItCNEN � . �m-� � �m� � i��4�"�1� �SS�1„r�L�' SC��DI��� 1 � 4.�4.�0 � c� � CONStRUGtION tYPE: CORICxINALLY NOt R4tED) G %i ;/;, i ii;� i� �ii� - - - - - � � PER CURRENT RENOY,4TION GUIDELINES: Tl'PE v-,4 RATED Ci HR SEPARAtION) FIREPLAGE � i AUtOM,4TIG SPRINKI...ER SYStFM: YES , ,'i ,i•�/i///,% � � SHEET SCALE 1/4"=1'-0" DRAWN BY CHECKED BY KB OCOPYRIGHT2008 BLUELINE ARCHITECTS P C PROJECT# 1004 NOtE: CONtR4CTOR t0 �IRE-StOP ALL SHEET TITLE• FLOOR PLAN PIPES � CONDUIt WHIGH P�N�TR4TE RA7ED PARt1' WALL ASSEMBLI=B � 2 ��O�O�� � �� �1�1 /'� � c� � o � � A1 ` ,�> >��.�� = ,�-��� D - APR 28 2010 F'L�4N NORt�-I - TOWN OF VAIL _ r � / �� � � j �--v o 0 U U ' � � U U � � N N E)Ct. � � � � N N � � . �INI�I F1.00R MAtERIAL STUD o0 00 L � I/4" MIN.ACOIJStIC UNDERLAYMENt � O � � � TG B� PLAGED BENEAtN NEW WOOD, ��N ,z�� � � .c .c S70N�,OR tILE FLOORING � � � ����CxYPGRE?� OR GELLIJLAR .� � CONC�TE TOPPINrs SLAB � � i,- - At DEMO LOGAtIONS,PLAC�NEW 5/8" �p � TYPE 'X' R4T�D GYP.BOARD � � - - - -` — - - - - �- -a- - -- 1x41U00DS1UDS16" O.C. t9/32" PLl'1U00D FLOOR SNEAtHING ' ' ��� StAGGE�D 8" O.G.ON 2x6 BASE -; �NIERIOR IADJAG�TIt 11Nlt p�A7� � _ WOOD AND STEEL�LOOR TRUSSES �� j ��� OF UNIT 2�6 ' OR COMMON i � NALLIUAY) 5/8"Csl'P.BD. � EXIStINCs CsYP.BOARD � ��� - �� 1 5/S°CsYP.BD. � EXIStINCx PLLIMBINCx PENE7RAtI0NS � t0 BE �A1.�D WItN RAt�p�I� j � � `i CAULK AT RATED ,4S�MBLIES 50lJND A7'I�NUAtION BA??S At I SOIJND At7�NUAtION BAttS j/ � - - - _; �rr�� �////O//// I/2"GALv.S7�EL �SILIEN1' - BEDROOMBATHROOM IUALLS � — — —n � GNANN�LS At 16" O.G. � �X ' _ 5/8" 7YPE 'X' RATED CsYP.BOARD t0 ����� F-- _ R�M GONtINU0l1S A7 IN?ERSECtING (2)L,4YERS 1/2" ?YP� 'X'Gl'P.BD� � - - - NON-RATED INtERIOR WALLS t �(A?SNOIUER AND TUB LOCAtIONS � U o IUITNIN R�h10DELED UNIt,FACE � I p LAYER 0�Gl'P.BD.t0 BE I NR � RAtED GONC�'I� W�780ARD) L j � o U fNOTE: ALL RA'I'�D IUALLS,FLOOR AND GEILING ASS�MBLI�S t0 B� GONS7RIJG7ED I'ER UL�N� 'NOt�: ALL RA?�D IUALLS,�LOOR,AND G�ILING ASSEMBLI�S t0 BE GONStRIJGl'ED i'�R IJL FIRE x .� • oa � RESISTANGE MANI,AL REQUIREMENt9 RE9ISTANCE MANUAI. REQUI�MENt9 m � � � � � � ON c � 3 T�'i�_ 1 �fi�. �'�T�D ��i�'./C�C�. �SS�1����' � T��. NON i��4T�� f�l�"�i�f Oi� UJ�4L� , T�'�. 1 -��' fi��4T�I� i=�fi�T�' UJ��� �- � � °° ' A2 1 I/2" = i'-0" UL L518 A2 1 1/2" = 1'-0" AZ I 1/Z" = 1'-0" UL U305/CsA FILE NO.WP3380 - STG RAtINCs OF 44 J W 0 w 0 � NN � � � �° o ^ � W �. � oo � Jzo J � � J � � a _ _ � Q � � a > > � � � . o � Wz � 0 '� � a Z � ' � Q � ISSUED FOR DATE PERMIT SUBMITTAL 41410 � � �� • .� , ���i� si,��'� � w �ia � SHEET SCALE AS NOTED DRAWN BY - CHECKED BY KB G. COPYRIGHT2008 BLUELINE ARCHITECTS P C PROJECT# 1004 SHEET TITLE WALUFLOOR DETAILS A2 � _ _ � � '