Please find accompanying, two (2) stamped sets of document for the Kelton
deck remodei.
Pians do not include any work inside the home. Remodel of the den has been
deleted from the scope of work.
Because of the low clearance for the existing and new deck, the rim is designed
to carry the load. I'm extending a double 2X6 over each pier to support the
outside rim. I've added a continuous 2X6 at the existing double 2X8 for
additional support and hQVe asked the contractor to uncover and verify the
condition of the existing rim.
The 12" diameter concrete foundation pier is governed by bearing. Therefore,
slenderness ratio does not require steel reinforcement.