Loading...
HomeMy WebLinkAboutA13-0085 Silent Knight � � ' • '• '� SILENT IntelliKnight° Model 5820XL KNIGHT Addressable Fire �" Alarm Control System by Hon�ywell The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description � 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding � � modules such as 5860 remote annunciator, 5815XL signalling ���-��-� line circuit expander, 5824 serial/parallel printer interface _ �� module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring ;�� location. i Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using � System Sensor protocol � �'t.����i�'R... • Built in support for 127 SD devices, expandable to 508 SD , .�- . devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator Model 5820XL • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECOO, • 6 amp power supply and maximum Gentex0, Faraday, System Sensor, and Wheelock0 charging capacity of 35 amp hours (An additional cabinet enclosure is required for • FlexputT"" I/O circuits batteries in excess of 18 amp hours) • Supports Class B (Style 4) and Class A(Style 6) configuration • Programmable date setting for Daylight for SLC, SBUS, and Flexput circuits Saving Time • 13 pre-programmed output cadences (including ANSI-3.41) and 4 programmable outputs Installation • Built-in annunciator with 80-character LCD display The 5820XL can be surface or flush • RS-485 bus provides communication to system accessories mounted • Built-in RS-232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC Compatibility • Improvements in SKSS software deliver five times faster The 5820XL signal line circuit (SLC) uploads/downloads supports multiple device types of the same • Two built-in Form C programmable relays rated at 2.5 amps protocol: at 27.4 VDC • SK (System Sensor) • Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing • SD single button operation of the reset and silence functions You cannot mix SD and SK SLC devices on a FACP. � � � • '• '� IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights 5820XL features a 6 amp power supply required to start a new system. The General Alarm (Red): Flashes when in and maximum battery charging built-in keypad and 5860 remote alarm; solid when alarm silenced capacity of 35 amp hours.An additional annunciator give on-site access to all cabinet enclosure (PN RBB) is required programming. You can also program Supervisory(Yellow): Flashes when a for batteries in excess of 18 amp hours. remotely using the 5660 Silent Knight supervisory condition exists; solid when Flexput circuits on 5820XL control can Software Suite, which is Windows°- supervisory silenced be individually programmed to function based software. System Troubles (Yellow): Flashes as notification circuits, auxiliary power when a trouble condition exists; solid outputs, or initiation circuits that guilt-In Digital CommuniCator when trouble silenced support both 2-and 4-wire smoke detectors. 5820XL features a built-in UL listed System Silenced (Yellow): On when an The 5820XL system operates on non- digital communicator for remote alarm, trouble or supervisory condition reporting of system activity and system twisted, unshielded cable when wired has been silenced but not yet cleared in compliance with standard wiring programming.The communicator has System Power(Green): Flashes for AC practices as called out in the National the ability to seize two telephone lines failure; solid when power systems are Electric Code 760-51 specifications for to report alarms and troubles to a normal power-limited fire protective signalling monitoring facility. The communicator cables. No special wiring is required. supervises two phone lines and will 5820XL rovides 13 reset notification activate a trouble signal if a line failure System Application p p is sustained for more than 45 seconds. 5820XL has one built-in signalling line cadence patterns (including ANSI 3.41) Other communication features include: circuit(SLC)which supports multiple and four user programmable selections retry if communication fails, two phone devices dependent on protocol being for fire alarm notification. number capability, download phone used. Three additional loops can be Two programmable general purpose number capability and Touch-Tone or added using the 5815XL SLC Form C relay outputs are provided on rotary dialing. The communicator is expanders to increase overall capacity. 5820XL. compatible with SIA and Ademco Additionally, the IntelliKnight system Contact ID. The format is selectable by The 5820XL SLC loops support features a built-in walk test and auto- multiple device types, including: account number. programming. Its innovative, dead-front • Addressable photoelectric smoke cabinet design allows for flush or — _ detector surface mounting. System maintenance • Addressable ionization smoke is easy to perform. detector User Interface • Addressable heat sensor The 5820XL built-in annunciator with • Addressable duct smoke detector 80 character LCD display and large • Contact module easy-to-use tactile touchpad can be .,;� • Relay output module used for system operation, programming and maintenance. It has � • Addressable notification module five LEDs for alarm, supervisory, • Addressable beam detector(SK system trouble, system silenced and _ � protocol only) system power. System operations • Addressable multi-criteria smoke include silencing alarms and troubles, AppYOVals detector(SK protocol only) resetting alarms and the display of NFPA 13, NFPA 15, NFPA 16, alarm troubles and memory.The NFPA 72: Central Station; Remote • Addressable multi modules (SK system's non-volatile event history protocol only) buffer stores 1000 events for viewing Signalling; Local Protective Signalling from the built-in or remote annunciator. Systems;Auxiliary Protected Premises The following advanced sensor Unit; &Water Deluge Releasing capabilities are available with 5820XL: System operation can be initiated with Service. Suitable for automatic, a mechanical firefighter's key or a valid manual, waterflow, sprinkler • Automatic drift compensation 4-to 7-digit operator's code. supervisory(DACT non-coded) • Maintenance alert programming signalling services. • Built-in sensor test to comply with The IntelliKnight system offers several Other Approvals: UL Listed; NFPA 72 calibration testing options to simplify and speed up CSFM 7170-0559: 135; requirements ro rammin The Jum Start�feature MEA 429-92-E Vol. VI; FM A p g g. p pproved minimizes programming I ' . � • �• .� IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Ir�telliKnight 5�20�CL �n�Facil"rtyased Addr�ssable Fire Alarm System ManagemenESoftwsre �j'��'�'Yc����-j� �'�n$AI"� PfptUGQ� Q�VIG�S Nfindows Based l[plDo�nnload Software � � ���� �_ � Compatiqle 95 � Receiver --- -°�- - � Automa[lon � Soflvuare � I�-t�► 582U7CL SK-2/2UD Connection VisorAlarm � IR Communicator 5895XL ir.r�, .--r✓„���� ' �edia��s ` � � �_ �,��� -R.� � � � �r��P�����r� � 1 ,. -�.� �-, � n � � Fzr31= ..- 5815XL S ���„��� �=_ �� —� � a'LCtso rdo� � 5860 582d � � � .tomo�e.nnuoaater I'rr�rGet rallfodule � _ �� ?i i us�1� »s nm) ��0. r 6 Flexput`"' �'��. Il0 Circuits '��a`'� 5815XL �= =i r F,,..�ndN_ can be fnputs - or outputs � 6 FlexputT" IJO Gircuits .F-- cart be inputs � _ �,' A or outputs _ ` +� E � oers,sonne�_no�n�.and N.ocs � O - - � � .��1 ���1 . _ F I S�Al;u�i15 ��n�l LYi��I'iPfl S�n�k=I'i�ta[�rcs �r- � � � �; ,s�'; � � '� SK-lon SK•Manitor SK-Iso SK-Control-6 SK•CoPorol B200SR SFC-Acclimate SK�2one-6 I��g;�.'"8'�. R.ddress��I Ad��e�seGle�ault.aolet�r l�dr�able 'aporns�y 3aun�er Mulfcr[era Zerte izki IJonito� Mo�]ule PI a0,a c�ra����, E�=;y s�i=��k? Inwiare 5860 eteci IJOdGk¢ ma7ul�3 MedulE do[eCror NI07alo �EmGtr.Arnun�:'�alof \/ "j.. �� � � � ... �# ...- `��� � 4 SK-Photo SK-NlanROr•2 SK-Relaymom2 SK-Heat 6224RB 622461 6210LP 5880 6KPI10[0-T =ualN�onzor �d7rassarla �-Mea[-gpR Relap �� --!-� FJ 1. ��pF Mccule Clua�'N nitar �{H��,ry; _ase e sa e=e LE 'va,R FllotcoladrlG ��'M'RYa'�s ."�,�-�'gsfabl6 I ptM�eduL GeiPCi:A' H�al ilefv�.�51�. � I ID � � I —__� i 0 � ssa3 Re'�v Incarf�r.e R1rx�i.ila 5K-Beam SK-Nbn-10 SK-PUII-17A 8di-C711[t SK-i�i�nlm6n SK-Itelay-6 SK-Zone SK-Relap � SK-Beam-T hdl- �able SK PUIF6R a�`��`-z�l_ Mcrhor F iay�=on r I qa7 �.�ati. qdrra,,.:tla � A:.cr�rablo M1��r r,� P 11res.ncGa Du�� Mocule McaWc erfa:z Rnlay 5e� f�tr,r,tor ��odule PuiIS`.3tlon D�eC..of IJar7�i.e IJ�otlli'�.e I � � � ___________� � � 5965-4 or5865-3 � Use th e 5880 to control u� to 4 � I _ED����cnci�ta� P {�hsasir:�r�n� � 5883 Relay Intertace Madules i � � � � �� .. IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications S-BUS Accessories _ Miscellaneous Accessories EleCtriCal 5860/R Remote Fire Annunciator 5660 Silent Knight Software Suite Primary AC: Features the same 80 character backlit (SKSS) 120 VRMS at 50/60 Hz, 2.5A or LCD display keypad and firefighter's User-friendly Windows software for 240 VRMS at 50/60 Hz, 1.4A keyswitch as the 5820XL. 5860 is gray remote programming of 5820XLs using Total Accessory Load: 6A @ 27.4 VDC, and 5860R is red. a PC. Upload and view panel account power-limited 5815XL Signal Line Circuit Expander information, event history, and detector Standby Current: 215 mA The SLC expander is used to add more status. Alarm Current: 385 mA addressable devices to the IntelliKnight 5670 Silent Knight Software Suite system. 5820XL supports three (SKSS) Flexput Circuits: 5815XL's. Each 5815XL can support 99 Powerful end-user facility management Six programmable circuits which can be SK detectors and 99 SK modules or software allows viewing of detector programmed individually as: 127 SD devices. status and event history via modem or Notification circuits: 3A @ 27.4 VDC 5895XL Intelligent Power Module direct connection. per circuit, power-limited Adds 6 amps of power, 6 Flexput I/O Plex-1 Auxiliary power circuits: 3A @ 27.4VDC circuits and 2 Form C relay circuits to a Dead front cabinet door with clear per circuit, power-limited 5820XL system. window to limit access to the FACP. Initiation Circuits: 100 mA @ 27.4VDC 5496 Intelligent Power Module RBB per circuit, power limited A 6 amp notification power expander Remote battery box accessory cabinet. that provides four power-limited notifi- Use if backup batteries are too large to PhysiCal cation appliance circuit outputs. fit into FACP cabinet. Dimensions: Flush Mount Dimensions: 5880 LED/10 Module 16"W x 10" H x 6" D 14.5"W x 24.75"H x 3.9"D Features 40 LED outputs, 8 normally (406 mm W x 254 mm H x 152 mm D) (36.8 W x 62.9 H x 9.8 D cm ) open dry contact inputs, and one piezo SD505-DTS-K output. Remote test switch. Used with Overall Dimensions: 5865-3 and 5865-4 SD505-DUCTR. Provides remote key 16.2"W x 26.4"H x 4.2"D Remote LED Annunciator operated test function and annunciation (40.6 W x 67 H x 11.8 D cm) Features 30 programmable LED (15 of detector alarm. red and 15 yellow)outputs, and a piezo SD and SK DeviCes Weight: 28 Ibs. (12.8 kg) sounder. The 5865-4 adds a silence See the specification sheets listed Color: Red and reset switch to the package. below for a complete listing of the SD Battery Charging Capacity: 7.0-35 AH 5883 Relay Board and SK devices. Features 10 general purpose Form C 53624 SD Devices Data Sheet Battery Size: 18 AH max allowed in relays. Used with 5880 module. 53623 SK Devices Data Sheet control panel cabinet. Larger capacity 5824 Serial/Parallel Printer batteries can be housed in RBB Interface Module accessory cabinet. Provides one parallel and one RS-232 serial port for connecting a printer to Telephone Requirements: the 5820XL. Use to print a real-time log FCC Part 15 and Part 68 approved of system events, detector status Type of Jack: RJ31X (two required) reports, and event history. Interfaces with building control system. This document is not intended to be used for installation purposes.We try to keep our SILENT product information up-to-date and accurate.We cannot cover all specific applications Made in Ame1'iCa KNIGHT or anticipate all requirements All specifications are subject to change without notice. For more information,contact Silent Knight 12 Clintonville Road,Northford,CT 06472 PN 350210 Rev H2 by Honeywell Phone:(203)484-7161,Fax:(203)484-7118.www.silentknight.com. O 2012 Honeywell International Inc. IntelliKnight&JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight , �. SILE�TT B200S KI�TIGHT � Sounder Base by Hor�eywell with CO Support The B200S sounder base sets a new standard for performance, installation ease, and aesthetics. It offers maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. BZ��S - _ The B200S sounder base series is designed for new and existing commercial dwelling unit applications. It offers �-�� maximum flexibility in installation, configuration, and ,, �,�, , � operation to meet or exceed UL 268 and UL 464 *� � ' requirements. � " "� �3 r The sounder base "listens in" to the communication � between the attached sensor head and the fire alarm 1, � w control panel (FACP) to adopt the same address as the � i - detector, but as a unique device type on the loop. The FACP can then use that address to command an individual -.�y� sounder—or a group of sounders—to activate. -`-�� �� When programmed for multi-station with a monitored -�_ conventional CO detector, the B200S can generate either a B200S SOUnder BaSe Temporal 3 pattern for fire or a Temporal 4 pattern for CO alarm indication. COrYlpatlfJl�lt�/ With its attractive aesthetics, the B200S is ideal to use for applications where the appearance is critical. For example, The B200S is compatible with the following SK- to eliminate unsightly surface-mount boxes, the sounder series detectors: base employs a separate mounting plate that can be • SK-Photo Photoelectric Smoke Detector and installed on various junction box sizes. In addition, the SK-Photo-T Photoelectric Smoke Detector with mounting plate enables pre-wiring of all connections to Thermal simplify the installation. The housing is installed with the • SK-Acclimate Multicriteria Photoelectric Smoke mounting plate and is locked in position with two retaining Detector screws. The retaining screws are covered by the installed . SK-lon lonization Smoke Detector sensor head for added tamper resistance. • SK-Heat Fixed Temperature Thermal Detector, Features SK -Heat-ROR Rate-of-Rise Detector with •Addressability for maximum configuration flexibility Thermal, and SK-Heat-HT Fixed High • Complies with UL� Standard 268 and UL�Standard 464 Temperature Thermal Detector • Offers a programming option to control and activate the sounder base independently The B200S is compatible with the following • Supports Continuous,ANSI Temporal 3, ANSI Temporal 4, IntelliKnight FACP's programmed for System and March Time tones • Employs multiple event-driven tone outputs Sensor protocol: (Firmware version of 13.0 or higher) • Uses a mechanical locking feature that prevents the 5700 removal of the attached sensor head • Capable of synchronizing with all notification appliance 5808 circuits on the same control panel on a general fire alarm 5820XL condition 5820XL-EVS , �. Model B200S Sounder Base � �W �— — — — — —9PTIONAL REMOTE 0.NNlJNiCIA70RMODEL RA400Zl�OOZ r _ ' �g I��LC � f �o � w� � � �o ! ;U (+J SLC. f ! � � / li ��i� �r !i r,�,1� 'I�'fi i��� � ii 'il ',-_ il ����,1 i� �i ���� �i ' �I i� II ik �' '�I f 1� �� i� �I I� ' lf _i. �I 1, I ,I, J j' J J ' . „ � � � Y � � � � � . �'' ■ �$ � . Bau 'a �� (+PSounderBase Pawer (-)S�ounder Base Pom�r �('1�IAC + (+ > u�usrEo Q EOL (-)NAC - L RESESTOR 4.7K Wiring B200S Installation Sound Output The B200S can be mounted directly to 4" (10.16 cm) High Volume Greater than 85 dBA minimum - square, 4" (10.16 cm) octagon, 3 1/2" (8.9 cm) octagon, measured in a UL reverberant single-gang or double-gang junction boxes. room at 10 feet, 24 Volts (in SpecifiCations continuous tone). Physical Ordering Information Height: 2.0" (5.08 cm) less B200S Intelligent Sensor Sounder Base sensor M02-04-01 Detector Test Magnet Width: 6.875" (17.46 cm) M02-09-01 Telescoping Test Magnet Shipping Weight: 0.50 Ib. (227 gm) Electrical External Supply Voltage 16 to 33 VDC (VFWR) External Supply Standby Current 500 �A maximum Alarm Current 35 mA maximum SLC Operating Voltage 15 to 32 VDC SLC Standby Current 300 NA maximum Environmental Operating Temperature: 32°F— 120°F (0°C — 49°C) Humidity: 10% —93% non- condensing SIL�NT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all K���',��' specific applications or anticipate all requirements.All specifications are FORM#351183 Rev B subject to change without notice. For more information, contact Silent Knight O 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com , �. SILENT Model 5815XL KNIGHT Signaling Line Circuit Expander ��� Add flexibility to IntelliKnight� applications by Haraeywell with the 5815XL SLC Expander The Model 5815XL SLC Expander is a signaling line circuit controller for Silent Knight's IntelliKnight 5820XL FACP or 5820XL-EVS FACP with Emergency Voice System. It allows you to add 99 SK modules and 99 SK devices or 127 SD addressable devices to the IntelliKnight system. Add up to three 5815XLs to a system to achieve the maximum number of devices on the system. 5815XL signaling circuits have the same functionality as the SLC that is built into the IntelliKnight panel and support the same addressable devices as the main panel. The 5815XL connects to the panel via the RS 485 bus. Model 5815XL Signaling Line Circuit Expander � ,},� ' .�� E ,�';' P°. The 5815XL expands the capabilities of the IntelliKnight fire ! control panel by allowing an additional 99 SK modules and �� ;���', �� �+� 99 SK detectors or 127 SD addressable devices to be � ���'"P,"; attached to the system. .'�' . .� ,q'����� �� All functionality of the built-in SLC is provided with the � i � � ' �'`�,�'��� �' A � � � 5815XL. Three 5815XLs can be added to an 5820XL or � �� �'��, � �f � � 5820XL-EVS IntelliKnight system for a total of 396 SK �'�� - - detectors and 396 SK modules or 508 SD addressable �.'-" r 4 devices per system. �� ` �'� � ��T �:�`,� �� � Operation �' The 5815XL communicates with the IntelliKnight FACP via 5815XL an RS 485 system bus.A green LED on the 5815XL board blinks to indicate good communication. If an addressable Specifications device on a 5815XL fails, the loop communicates the failure to the panel and continues to operate normally. System Capacity 5820XL FACP supports Features three 5815XL SLC Expanders. Each • Adds 99 SK modules and 99 SK detectors or 127 SD expander supports 99 SK addressable devices to an 5820XL/EVS IntelliKnight detectors and 99 SK system modules or 127 SD • Three 5815XLs per system addressable devices. • 5815XL SLCs have same functionality as the Operating Voltage 24 VDC 5820XL/EVS, including Style 6 (Class A) configuration Current Draw 55 mA minimum - • Communicates with the IntelliKnight panel via RS 485 125mA max. system bus Ambient Temp. 32°F to 120°F • LED indicates good communication (0°C to 49°C) • UL 864 listed, complies with NFPA 72 and 101 Mounting Inside 5820XL, • Communicates on most standard wiring systems (ideal 5895XL cabinet, or for retrofits) 5815RMK cabinet • FM approved; CSFM approved; MEA � •- Model 5815XL SLC Expander Engineering Specifications The contractor shall provide a signaling circuit expander compatible with the IntelliKnight 5820XL fire control panel that allows 99 SK Modules and 99 SK Detectors or 127 SD addressable devices to be added to the system. The IntelliKnight panel shall support three expanders per system. The expanders shall provide signaling line circuits that have the same installation and functionality as built-in SLCs and shall communicate to the main panel via an RS 485 system bus. A green LED on the expander board shall blink to indicate communication with the main panel. FACP 5815XL 23 22 21 20 19 18 17 1 fi SG S+SC-S+ ' II� + A B + p S + A B IN OUT � 'i � , ' <_% � n �� � � _ � � � � +!;II�I Us d in ro s�c usEd ror _ Loop Sryle 6 SLC 0 � C,�255.4 � Configuration � configuretions ,,,. I� . _ T {r"��.. ia r , ,�'� ,�� � , 3 �'�,9'r. � ��^.�F �.�.. ��.r NIiM .m,.+akp5�.�. Mode15815XL Mode�:3315XL� SLC Loop t SLC Loop 2 SLC Loop 3 FACP Cabinet 5815XL Block Diagram SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA KNIGHT to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350098 Rev G , subject to change without notice. For more information, contact Silent b Hone Well Knight 12 Clintonville Road, Northford, CT 06472-1610 O 2013 Honeywell International Inc. y Y Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com � •- SILENT 5860 Remote Annunciator KNIGHT �, by Honeywell Bring the power to control an IntelliKnight fire alarm control panel to every area within your facility. Now you can operate and program your IntelliKnight system from up to eight locations throughout your facility. The 5860 remote annunciator provides the same advanced, easy-to-use interface found on the IntelliKnight panel's built-in annunciator. The 80-character display and ergonomically designed keypad allow for simple and error-free system operation.All operations—including reset, silence, detector status checking, fire drill, and programming—are identical. Access to the system is through a firefighter's key or an access code. For security, a special installation code is needed for programming functions. The 5860 connects to the IntelliKnight panel via the RS-485 system bus. Wire runs can be up to 6000 feet from the panel. For more information about the IntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description multiple 5860s Features include an 80-character • RS-485 interface to panel backlit LCD providing easy-to- • Operation and appearance is understand system messages. The identical to 5860 built-in annunciator is ergonomically annunciator - designed with over-sized buttons • On-board piezo sounder audibly �� for the most frequently used indicates alarms, troubles, and features, like Reset and Silence. supervisories In addition to status messages ' Five status LEDs for alarm, ,-- supervisory, trouble, silence and displayed on the LCD, there are AC power conditions � five LEDs for alarm, supervisory, . Wiring lengths up to 6000 ft. from trouble, silence, and AC power the FACP (depending on wire status. gauge and number of devices on 5860 The annunciator is available in gray SBUS) Environmental to match virtually any decor and ' UL listed, complies with NFPA 72 Operating Temperature: 32°F – red for applications where the • CSFM approved 120°F (0°C –49°C) annunciator must stand out. The Electrical Specifications Humidity: 10% –93% non- annunciator enclosure can be Operating Voltage: 24 VDC condensing surface or flush mounted.A trim Standby Current: 20 mA max Compatibility ring kit is available for surface The 5860 is com atible with the mounting. Alarm Current: 25 mA p Wiring Distance: 6,000 max. from following FACP's: Features FACP (depending on wire gauge • 5820XL Addressable Fire Control • 80-character backlit LCD display and number of devices on the Panel (4 lines with 20 characters on SBUS) • 5820XL-EVS FACP with each line) Emergency Voice System • Tactile and audible feedback Max Per System: 8 • 5808 Addressable Fire Control • Accepts user codes or fire Mechanical Specifications Panel fighter's key Physical 9.1" W x 7.4" H x 1.5" D • Larger keypad buttons for system (23.1 W x 18.8 H x 3.8 D cm) • Pa�elAddressable Fire Control reset and silence Shipping Weight: 2.8 Ibs (1.3 kg) Listings • Install up to eight 5860s per FACP Color NFPA 72; UL Listed; • Available in red or light gray 5860R: Red CSFM 7170-0559: 135; • Support for simultaneous use of 5860: Gray MEA 429-92-E Vol. IX; FM Approved � •� 5860 Remote Annunciator Engineering Specifications The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote annunciators shall have the same control and display layout so as to match the appearance of the built-in annunciator. Remote annunciators shall be available in two colors, red or light gray. Remote annunciators shall have identical functionality and operation as the built-in annunciator.All annunciators must have an 80-character LCD display and must feature five LEDs for: General Alarm, Supervisory, System Trouble, System Silence, and System Power. All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a travel of .040 inches. No membrane style buttons will be permissible. The annunciator must be able to silence and reset alarms through the use of a code entered on the annunciator keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the operating system programming to authorized individuals. The control panel must allow all annunciators to accommodate multiple user input simultaneously. ` � - 'i'4�Ir�r�.uae�4�y l��1�P'r�-! I?ufii F�41C:P �— � � � � � 9�11� i;�'...�,. 'i;.:� ,�. -�a�+• �� � �� � �� � ��� ��! `��4 ��!4�����4���`4�Gf�l � — �,+JLdI.�l6"�.e�'i�t ICI:-�E'.-.��il'il�l'il�.p.�� Ordering Information 5860R Remote Annunicator four line LCD annunciator with 20 characters per line. Red. 5860 Remote Annunciator.Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring for surface mounting. 5860TG Gray Trim Ring for surface mounting. S��,E�'�" This document is not intended to be used for installation purposes.We try to MADE IN AMERICA I<NIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350224 Rev F subject to change without notice. For more information, contact Silent Knight O 2013 Honeywell International Inc. by HOneyw211 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com , �. SILEl�TT SK-FIRE-CO KI�TIGHT � by Hor�eywell Advanced Multi-Criteria Fire/CO Detector SK-FIRE-CO offers world-class fire and carbon monoxide (CO) detection combined in a single addressable device to provide a practical and cost-effective solution for today's market. For more information about the SK-FIRE-CO, or to locate you nearest source, please call 800-328-0103. SK-FIRE-CO � The SK-FIRE-CO is a plug-in, addressable device that J�-,�� provides both fire and carbon monoxide (CO) detection. For � � fire, the detector combines four separate sensing elements � � in one unit (smoke, CO, light/flame, and heat) to sense �� multiple components of a fire. This approach enables ti�1 enhanced sensitivity to real fire with heightened immunity to � `d nuisance particulate. For CO, the detector's electrochemical sensing cell creates a separate signal for life safety CO � detection. ;��� o _ Released through the incomplete burning of various fuels, �',_� CO is a colorless, odorless and deadly gas that is virtually �� impossible to detect with the human senses. Because the '�„ �.� potential exists for dangerous levels of CO to accumulate in �'— almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The SK-FIRE-CO is listed to SK-FIRE-CO installed in a the UL 2075 standard for system-connected life safety B200S Sounder Base (sold separately) carbon monoxide monitoring. • RealTestO CO testing capability The SK-FIRE-CO should be used in conjunction with the • UL 268 and UL 2075 listed B200S intelligent sounder base (sold separately), which can • Separates audible signal for fire or CO alarm generate either a Temp 3 pattern for fire or a Temp 4 when used with the B200S base pattern for CO alarm indication. With each sounder base • CO cell end-of-life warning and fault learning the address of the detector connected, the FACP can then command an individual sounder, or a group of Compatibility sounders, to activate. The command set from the panel can The SK-FIRE-CO is compatible with the be tailored to the specific event, allowing selection of tone, following IntelliKnight FACP's programmed for and group. For more information on the B200S refer to Data System Sensor protocol: (Firmware version 13.0 Sheet P/N 351183. or higher). SK-FIRE-CO can also be used with the B210LP 6" standard • 5700 base, the B200SR sounder base or the B224RB relay base. • 5808 Features • 582oXL • 5820XL-EVS • Unique ability to detect all four major elements of a fire: - Smoke - Carbon Monoxide (CO) - Light/flame - Heat • Separate CO detection signal • Highest nuisance alarm immunity •Automatic drift compensation of smoke sensor and CO cell • Uses only one address on the SLC Model SK-FIRE-CO Multi-Criteria CO Detector Specifications Ordering Information Physical SK-FIRE-CO Multi-Criteria CO Detector (base Diameter: 6.875" (17.46 cm) installed in a not included) B200S base Height: 3.46" (8.79 cm) installed in Optional Accessories B200S base B200S Intelligent sounder base Shipping Weight: 4.6 oz B210LP 6" mounting base B200SR Sounderbase Color: Ivory B224RB Relay base Operating M02-04-01 Detector test magnet Temperature Range: 32° F to 100° F (0° C to 38° C) M02-09-01 Telescoping test magnet Humidity: 15 to 90°/o relative humidity (non-condensing) Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Operating Voltage: 15 to 32 VDC Maximum Standby: 300�A at 24 VDC (no communication every 5 seconds with LED blink enabled) Maximum Alarm Current (LED on): 7.2 mA at 24 VDC CO Monitoring UL Standard Reference -Alarm Thresholds are as follows: arts er i ion etector esponse ime 70 ± 5 ppm 6 - 40 min. ± ppm - min. ± ppm - 5 min. Note: Per UL Standard 2075, the SK-FIRE-CO has been tested to the sensitivity limits defined in UL Standard 2034. SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject to change without notice. For more information, contact Silent Knight FORM#351181 Rev C by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800)328-0103, OO 2013 Honeywell International Inc. Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com � •- SILENT SK-Heat, SK-Heat-HT KNI�T�T and by H�o�eyweii SK-Heat-ROR Addressable Thermal Heat and Rate-of-Rise Detectors The SK-Heat, SK-Heat-HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description ��S�b�i�ty ���� SK-Heat, SK-Heat-HT and SK- • Detector transmits signal to Heat-ROR are intelligent sensors indicate maintenance is required _ that utilize a state-of-the art • Plug-in mounting provides ease thermistor sensing circuit for fast of installation response. Sensitivity is • Optional remote LED annunciator continuously monitored and (System Sensor-0 PN RA100Z) �� reported to the FACP. Point ID capability allows each detector's • Tamper-proof feature available on address to be set with rotary mounting bases address switches, providing exact • Rotary address switches for fast SK-Heat (base included) detector locations for selective installation SK-Heat-HT: High temperature heat maintenance when chamber • UL Listed sensor 135°F - 190°F (57°C - 88°C) contamination reaches unacceptable levels. SpeCIflCatIO11S SK-Heat-ROR: Rate-of-rise SK-Heat is a fixed temperature Physical detection 15°F/min (8.3°C/min) sensor that uses a thermistor Height: 2.0" (51 mm) Compatibility sensing circuit to produce 135°F Diameter: 6.1" (155 mm) installed (57°C)fixed temperature alarm. in B210LP base The SK-Heat-HT and SK-Heat- Shipping Weight: 4.8 oz (137 g) ROR are compatible with the SK-Heat-HT is a variable high following IntelliKnight FACP's: temperature detector that provides Electrical high temperature detection at Operating Voltage: 5820XL 135°F - 190°F. (57°C - 88°C) 15 to 32 Volts DC Peak 5808 SK-Heat-ROR is a rate-of-rise Standby Current: 5700 temperature sensor with 135°F 300�A @ 24 VDC The SK-Heat is compatible with the (57°C)fixed temperature alarm. LED Current: 6.5 mA@ 24 VDC following IntelliKnight FACP's: Features Environmental 5820XL 5808 • Reliable analog communications Operating Temperature 5700 for trouble-free operation SK-Heat & SK-Heat-ROR: 5600 (Rev 2.0 or higher) -4°— 100°F (-20°C— 38°C) • Age resistant polymer housing The SK-Heat, SK-Heat-HT and SK- • Innovative thermistor sensing SK-Heat-HT: -4°— 150°F Heat-ROR are compatible with the circuit (-20°C —66°C) following detector bases: • Superior EMI resistance for Humidity: 10% — 93% B210LP 6" base (included) reliability noncondensing B501 2 wire base • Variety of mounting options to Thermal Ratings B224B1 Isolator base meet any application SK-Heat: Fixed temperature alarm B224RB Relay base • Dual LED indicators for 360° 135°F (57°C) B200SR Sounder base � •- Model SK-Heat, SK-Heat-HT, SK-Heat ROR Addressable Thermal and Rate-of-Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK-Heat, SK-Heat-HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. `�� � ���s�c' � � IN OUT -�,� • Compat�ble FACP � E+ .— + — RA100Z(Optional) + — � ........................ 3 2 3 Z 3 z 1 1 :'� 1 � EE................................................................................................................................................................................. � .................................6 E E Class A Optioraal Wiring ' :` :....................................................................................................................................................................................... ...................................................................., Wiring SK-Series Detector Mounting Bases Accessories M02-09-00-Test Magnet with Telescoping Handle. RA100Z-Remote LED Annunciator. XP-4-Extension Pole for XR2B. Extends from 5—15 ft. RMK400-Recessed Mounting Kit. Provides low profile for use with T55-127-000-Detector Removal Head. B501. XR2B-Detector Removal Tool.A removal and re-placement tool BCK-200B-Black Detector Kit. For SK-series detectors. for SK plug-in detectors. Includes the T55-127-000. 'Unless otherwise noted, specifications apply to all SK thermal M02-04-01 -Replacement Test Magnet. detectors. S����.,I, This document is not intended to be used for installation purposes.We try to MADE IN AMERICA keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are subject FORM#350120 Rev. D1 to change without notice. For more information, contact Silent Knight 12 O 2013 Honeywell International Inc. by Honeywell Clintonville Road Northford, CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support call 800-446-6444. www.silentknight.com � •- SILENT SK-Minimon KN�GHT by Haneywe�� Intelligent Mini Monitor Module The SK-Minimon addressable mini monitor modules for use with Silent Knight IntelliKnight fire alarm control panels (FACP). The SK-Minimon is designed to be used with pull stations, water flow switches, and other applications requiring dry contact alarm initiation devices. For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description The SK-Minimon is an addressable monitor modules for use with the IntelliKnight fire alarm control panels (FACPs). The SK-Minimon acts as an interface to contact devices, such as waterflow � switches and pull stations. �,.� �r,�� The SK-Minimon supports Class B �.- �� � supervised wiring to the load �, � device. Conventional 4-wire smoke —� - detectors can be monitored for alarm and trouble conditions The SK-Minimon can be mounted in a single gang junction box directly behind the monitored device. Its small size and light SK-Minimon weight allow it to be installed without rigid mounting Specifications Compatibility requirements. The SK-Minimon is compatible with Electrical the followin IntelliKni ht S stems: Features Standby Current: 400 uA max @ g g y • Single contact monitor 24 VDC with comm. 5820XL • SK-Minimon support for Class B Voltage Range: 15 - 32 VDC 5820XL-EVS (Style B) contact monitor wiring End of Line Resistance: 47 k Ohms 5808 5700 • Small and lightweight size allows physical 5600 (Rev 2.0 or higher) for flexible mounting options Dimensions: SK-FFT • Rotary address switches for fast 2.75" W x 1.3" H x 0.5" D installation Weight: 1.2 oz (37 g) • UL listed Environmental Listings Operating Temperature: UL 32°F– 120°F (0°C –49°C) CSFM Humidity: FM 10% –93% non-condensing � •� SK-Minimon Intelligent Monitor Module Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable monitor modules Silent Knight SK-Minimon. The modules shall be UL listed and compatible with Silent Knight's IntelliKnight FACPs. The SK-Minimon shall be installed inside a single gang junction box directly behind the monitored unit. � I '�'11 + IN �i.,;] — QUT C�.;] + r^ _ i5a 7 ADDRESS � � '13 � 3 � ,2 - 12 '�3 � ,I'',3 Compatible FACP �� ��� �� '�'4 ��� �.':';�4 �9 s 7�'�� LooP � $��'�5 `�`��� � QNES - + t - � [�p Q t�D Y9 Q- R � r� � t)ther Devices Wiring the SK-Minimon SILENT This document is not intended to be used for installation purposes.We try MADE IN AMERICA to keep our product information up-to-date and accurate.We cannot cover KNIGHT all specific applications or anticipate all requirements.All specifications are FORM#350133 Rev E subject to change without notice. For more information, contact Silent O 2013 Honeywell International Inc by Honeywell Knight 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please Call 800-446-6444. www.silentknight.COm •- SILENT SK-Photo, SK-Photo-T K1tiTIGH'I' and n SK-PhotoR by Honeyr�ell Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description • Optional remote LED annunciator (System Sensor0 PN RA100Z) SK-Photo and SK-Photo-T are plug-in . Plug-in mounting provides ease of type smoke sensors that combine a installation � photoelectric sensing chamber with . Tamper-proof feature available on addressable analog communications. mounting bases ' Point ID capability allows each detector's address to be set with rotary ' Listed for use in duct applications � � address switches, providing exact • Rotary address switches for fast detector locations for selective installation maintenance when chamber • UL Listed contamination reaches unacceptable • FM A roved � pp � levels. SK-Photo and SK-Photo-T have a Specifications � unique optical sensing chamber that is Physical engineered to sense smoke produced Height: 2.0" (5.0 cm) SK-Photo (Base included) by a wide range of combustion Diameter: 4.1" (10.4 cm) installed in sources. In the SK-Photo-T, dual B501 base electronic thermistors add 135°F (57°C) Installation thermal technology to maximize Electrical detection. Operating Voltage: 15-32 VDC The SK-Photo and SK-Photo-T plug Standby Current: into a compatible IntelliKnight-series The SK-PhotoR is a remote test detector base. The SK-PhotoR is a capable detector for use with the 300 �A @ 24 VDC Maximum remote test capable detector head DNR/DNRW duct smoke detector. (not Alarm Current: 6.5 mA @ 24 VDC max included within the DNR (W)duct included) (with LED on) smoke detector. Environmental Operating Temperature Compatibility Featu res SK-Photo: 32°— 120°F (0°C—49°C) SK-Photo, and SK-Photo-T are • Sleek, low-profile design SK-Photo-T: 32°— 100°F (0°C—38°C) compatible with the following detector • Base included Humidity: 10%—93% non-condensing bases: • Reliable analo communications for Other Ratings B210LP 6" base (included) g B501 2 wire base trouble-free operation SK-Photo-T Thermal: Fixed g224RB Rela base • Age resistant polymer housing temperature set point 135°F (57°C) g224B1 Isola or base • Dual electronic thermistor design on Velocity: 0—4000 fpm (0—20 m/sec) g200SR Sounder base the SK-Photo-T The SK-Photo, SK-Photo-T, and SK- • Superior EMI resistance for reliability PhotoR are compatible with the • Simple field cleaning for code following IntelliKnight FACPs: compliance 5820XL • Variety of mounting options to meet 5820XL-EVS any application 5808 • Dual LED indicators for 360°visibility 5700 5600 (Rev 2.0 or higher) • Detector transmits signal to indicate maintenance is required � •- Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent KnighYs IntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B210LP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. / -'� / s�c � IN OUT r -r�-_`�rq gompatible FACR � ;+ s_.+ - RA100Z(pptional) + - f ........................ 3 2 3 Z 3 z 1 1 ;� 1 � ; E.......................................................................................................................................................................................... f .................................c E ` .................................................................Class A Optional Wiring I E :............... .......................................................................................... ....................................................................., Wiring SK-Series Detector Mounting Bases SILENT This document is not intended to be used for installation purposes.We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are FORM#350118 Rev E subject to change without notice. For more information,contact Silent Knight O 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford,CT 06472-1610 Phone: (800)328-0103, Fax: (203)484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com �� SYSTEM _ _ _. ��� SENSOR° � � � �� +� - '� � - � _ - ---,,, �- - - Mini-Horns =���� � , �,� .� , -_°��-� � ' �,:.� =� ��� �� The SpectrAlert�Advance series of mini-horn sounders � � � -� _ are designed to simplify installations to provide ;, _ _�__=-�. � � ° ,;. r+; primaryand secondarysignaling forfire and security �� ____ _ � ,. applications. SPECTR�Iert A � V A N C E Features The MHR and MHW mini-horns operate at 12 and Z4 volts and are •12 and 24V operation ideal for hotel,motel or residential fire system applications,where a smaller notification device is desired.The mini-horns offer high •High and low volume settings and low volume settings,and temporal or non-temporal tones. The •Temporal and non-temporal tones horns can be mounted to single gang back boxes for aesthetically •Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. •Compatible with MDL sync module •Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-Alert'°sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. Agency Listings �` �� ° F M MEA � �;C� LISTED APPROVED approved �v, 5401i 3028007 MEA7�07-E 7�3;-1653:79fi SpectrAlert�Advance Mini-Horn Specifications Mini horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.When used with the Syno-Circuit°°Module,12-volt rated notification appliance circuit outputs shall operate between nine and 175 volts;24 volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.6`L x 2.9"1N x.45""D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single gang back box(23/4""deep) Flush:Standard 4"x 4"back box InputTerminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data . Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16-33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-tempora) High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 _ � 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 Z Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 ZS 4 Non-temporal Low 17 13 21 19 Ordering Information .- MHR Mini Horn,Red MHW Mini Horn,White �� SYSTEM ezoo�system sen=o�. 3825�h10 f�V2YlUe•St.�{ldY�eS,��6�174 'roductspe6�ca�onssubjecttorn gewithout otre.uis�sysremsensor.comfor ��� �����R Ph0112:8��-SENS�RZ•FdX:63�-3��-6495 cwrenrprod c[nfoimation�dud-ng�helai s[versionofthlsda[asheet. Aos-04ta oo •i�io9 nz26s �� SYSTEM ��� SENSOR� � �'� � �. � � ���� . �� � _ .��' . �� Selectable-Output � �'�..� Horns, Strobes, and � � Horn Strobes -_,i� � SpectrAlert°Advanceselectable-outputhorns,strobes, ' ` "���' and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTf��C� A � V A N E Features The SpectrAlert Advance series offers the most versatile and •Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. •Tamper-resistant construction With white and red plastic housings,wall and ceiling mounting options,and plain and FIRE-printed devices,SpectrAlert Advance can •Automatic selection of 12-or 24-volt operation at 15 and 15/75 meet virtually any application requirement. candela •Field-selectable candela settings on wall and ceiling units:15, 15/75, Like the entire SpectrAlert Advance product line,horns,strobes, 30,75,95,1 10,1 15,135,150,177,and 185 and horn strobes include a variety of features that increase their •Horn rated at 88+dBA at 16 volts application versatility while simplifying installation.All devices •Rotary switch for hom tone and three volume selections feature plug-in designs with minimal intrusion into the back box,which make installations fast and foolproof while virtually •Universal mounting plate for wall and ceiling units eliminating costly and time-consuming ground faults.Furthermore, •Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed,protecting devices •Electrically compatible with existing SpectrAlert products from damage. •Compatible with MDL sync module In addition,field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings '-=��;;�..�,� SIGNALING I(��,��1 O �� � o� F M MEA `'� a roved �,zs-�bsa�8e���,�oo�s«o�es� LISTED aarAOVeo PP �izs-ies3:�aamo�nsc����s, 540'l(chimes,ho:nstrobes,horn) 3023577 MEA452-OS-E chlrnesvobes) SSSl7(sttobes) 7135-1653:189(homs,chirnes) SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 1�/z-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1'/s-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the SynoCircuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynaCircult Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts,24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings induding 15,15/75,30, 75,95,1 10,115,135,150,177,and 185. Strobe The strobe shall be a System Sensar SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective serviceThe strobe shall be wired as a primary signaling noiification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4"/,e x 4"/,6 x 2'/a-inch back box.The module shall also control two Style Y(dass B)circuits or one Style Z (dass A)circuitThe module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F(0°C to 49°q Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 175V(12V nominaq or 16 to 33 V(24V nominaD InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(induding lens) 6.8""diameter x 2.S"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(induding lens) 5.6""L x 4.7""W x 2.5`D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"'L x 4.7""W x 13`D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9""L x 5.0"W x Z2`D(151 mm L x 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions(BBSG2,BBSCW-2) 7.1""diameter x 2.2`high(180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW-HS) 5.7"'L x 4.8""W x 035"D(145 mm L x 122 mm W x 9 mm D) Ceiling-MountTrim Ring Dimensions(sold as a 5 pack)(TRGHS,TRCW-HS) 6.9""diameter x 03S"high(175 mm diameter x 9 mm high) Notes: L Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-007 UL Current Draw Data � � 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d6 DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 U6 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 - � - 8-17.5 Volts 16-33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 . 16-33 Volts 16-33 Volts DClnput 135 150 177 185 FWRlnput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data . 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern d6 DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 �Settings 7,8,and 9 are not available on 2 wire horn strobe. A05-0395-007 SpectrAlert Advance Dimensions �4.7" 25" _ 6.8" Dia. ��,e... � 5 ,� , � __ � ��a _.,� /; � � � a� � �� � 0 ' � / _s---�___1- ' , I 2.5' 5.6` 7.`' �� �'�,.`.....,�� — a ' � Wall-mount horn strobes Ceiling-mount horn strobes 7.1" I'-2.25� 5.05'� �«223�I Dia. � I I OOo� a OOo�C� 5.95" 0 0 0 � o � � � ° � � Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information •- �- Wall Horn Strobes Ceiling Strobes P2R*' 2-Wire Horn Strobe,Standard cd$,Red SCR Strobe,Standard cd,Red P2RH* 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red P2Wx 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White P2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White P4R* 4-Wire Horn Strobe,Standard cd,Red Horns P4RH 4-Wire Horn Strobe,High cd,Red HR Horn,Red P4W 4Wire Horn Strobe,Standard cd,White HW Horn,White Wall Strobes Accessories SR*' Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red SRH*' Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White SW�` Strobe,Standard cd,White BBSC-2 Back Box Skirt,Ceiling,Red SWH' Strobe,High cd,White BBSCW-2 Back Box Skirt,Ceiling,White Ceiling Horn Strobes TR-HS Trim Ring,Wall,Red PQR� 2-Wire Horn Strobe,Standard cd,Red TRW-HS Trim Ring,Wall White PQRH 2-Wire Horn Strobe,High cd,Red TRC-HS Trim Ring,Ceiling,Red PCZW*' 2-Wire Horn Strobe,Standard cd,White TRCW HS Trim Ring,Ceiling,White PC2WH* 2-Wire Horn Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red PC4RH 4Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standard cd,White Notes: *Add"-P"to model numberfor plain housing(no°FIRE°marking on cover),e.g.,P2R-P. t Add"-SP"to model number for°FUEGO"marking on cover,e.g.,P2R-SP. #"Standard cd"refers to strobes that indude 15,15/75,30,75,95,110,and 115 candela settings."High cd°refers to strobes that indude 135,150,177,and 185 candela settings. �� SYSTEM ozoo�s,,em sen=o�. 3825�h10 f�V2YlUe•St.�{ldY�eS,��6�174 ?roductspe6�ca�onssub�rcttorn gcwithoutnotrce.uis�sysremsensor.comfor ��� �����R Ph0112:8��-SENS�RZ•FdX:63�-3��-6495 curcen[produc[Inforrna[ion,�mduding[helarestversionotthlsdatasheet A05-0395-007•4/09•II2132