Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B13-0481 REV 2 TRANSMITTAL & DOCUMENTS
TOWN OF VAtL Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of $110 will be charged upon reissuance of the permit. Application /Permit #(s) information applies to: Attention: () Revisions 3.13 oLtsl (%A"K t64ba lA. 5 �X&-YA- 1, q P_ ( ) Response to Correction Letter _attached copy of correction letter ( ) Deferred Submittal (� Other Project Street Address: 3� W 66yr ways �y��-e- . l.G v ►�.d WY (Number) (Street) (Suite #) Building /Complex Name: CASCa.00 Description of Transmittal/ List of Changes, Items Attached: Applicant. Information (architect, contractor, owner /owner's rep) Contact Name: r ��- `�h�xC ►� Address: dZ Z.lo City NJ Ov/1 State: Lo Zip:st (P 10 W a.t1 -%b-P 5b"- u L L -%.%+l Contact Name: (use additional sheet if necessary) Contact Phone: COO 35,o 19 8 N' Building Permits: Revised ADDITIONAL Valuations (Labor & Materials) Contact E -Mail: `J �+�� OD ®� -tuC. C O�"�. (DO NOT include original valuation) I hereby acknowledge that I have read this application, filled out Building: in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to Plumbing: comply with the information and plot plan, to comply with all Town ordina s d s ate laws, and to build this structure according Electrical: to th t n' zoning and subdivision codes, design review ap- pro Inte ational Building and Residential Codes and other Mechanical: ord' nces o the Town applicable thereto. X Total: Owner /Owner's RL"sentative Signature (Required) For Office Use Only: Fee Paid: Received From: Cash CC: Visa / MC Last 4 CC # Authorization # Check # exp. date: Date Received: S'b01 00 $ 51S"�6• o0 D w�C i i 2013 TOWN OF VAIL 0 w o�mmr 'coop O 0 IV-0 -0 D� CO) DDD = _0 r _ _� _ =0 = 'D m � �0MM �C00 wr D y 0 0 0 1 0 0 DDD0000 00022 x000 v m m r r" C) m 0 m C- C- .(�.1 —mm r- mDm-f c 0 Z ZZDO r, mmmmmzmmm _m�= O ; ak 0 —Z-1-1 DMn m c Z Z cnG)�.. rm0 v CO) DD -4 f �" w M 2Cl) ZOCcao, Z 0 M M A D A m 0 Z m m (n m C 0 Q. D Z J � O C" o ca A ca A D W o_Ny cn m O o o V V V A O OD V O o C)- w S w w S aoS x — a � 0 i m > 0 m ms ) c AW o oo S n — m o V V V 1`0 ` Z O n x m Z I 0 I=atyf� 0 0 0 0 0 0 NC— ommW0 Z I I I Cal t m V co W -+ CO V OI CO __ m V Cn W m V VA W r m icm� 00• v Z czoa AA NOOD0) W WW co NC)W0)AN0W0)ANO W NNNNN - -- co0)AN () W o m °i= w w yor�yCal w w w ci a 0 r- ; 0 0 0 t7 O$q� � W CD O Ln W O fop o #W D N CD Z y 0 A N N W O D i Z On O) 0) V # V c 4 CID K) z ;t III i to NAa D ;ySy (') o W 0 cn 0 p Q o ao'oD�pZ O �O +s °' u�i p► DnZ�G? 5! )b cc � m ca y�m� Rte W o po w ao 0 Z t)Z,r"a I"IC) ao w S W t~)1 A� �� O S y = =_ _ __ _ _ _ = s a s s a a CO) m a y a a m A (Nn V 0 30 r" w D i m i m i m 2 �Kox '"mOZ c 0 a y r o< ?' • `D`�F oar �� v m N w o Z 2 0 -� O o S y a A 2 T rA nl _ H • � FN •r«u 4'�� r N \ � w m E 90 r ©r- > =•@ > _= m 43 •_ 2 O m -U C00 O00m3 »MmM �0 o r 0 m2C- C- �2k> > k 'U xk -4� Dr-0 m 0) 0 -j- -0 rm0 O E �� m Z 2CG■ 0 d -n2g 2 0 r -n c k CL Q � 0 0 0 o k » Al o� lo @ 2 P CD 0 mokwo 0 0 0 o k o CD 7 lo> co CD ® ( m 0 0 0 0 o 0 CD v @ 101 > M 0 0 0 -41 otwom w w w > C" C" C" mc" a # #a 0 WwC" w — CO wmw m ■1" owm# C" c" �c" o4" ■# D. 0 To co � � � o o ° 3 m N 0 0 0 o k o �, 2 Cl w " ■ # w . C"o -4 COo Co 0 0 0 . � % m�00 > I .. r Q m m �km 0 0 0 o k o n 0 OD @ v $o &oo> _ _ 0 _ _ > _ = I O # -4 0 m 0 >�� m 90 , d Q < ~\ ^0 0 co zƒ » ��'\a� SS 1P U C NW us Classified by Underwriters Laboratories, Inc. to UL 2079 and CANNLC -5115 System No. HW -D -0045 Assembly Rating —1 and 2 Hr (See Item 2) Nominal Joint Width — 314 In. Class II Movement Capabilities — 33% Compression or Extension SECTION A -A 1. Floor Assembly — The fire -rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described in the individual Floor - Ceiling Design in the Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Form Units* — Max 3 in. (76 mm) deep galv steel fluted floor units. B. Concrete — Min 2 -112 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units. 1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof - Ceiling Design in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof assembly shall include the following construction features: A. Steel Roof Deck — Max 3 in. (76 mm) deep gaiv steel fluted roof deck. B. Roof Insulation — Min 2 -1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the floor units. 2. Wall Assembly — The 1 or 2 hr fire -rated gypsum board /stud wall assembly shall be constructed of the materials and in the manner specified in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Steel Floor and Ceiling Runners — Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of gaiv steel channels sized to accommodate steel studs (Item 213). Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width.. Ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel fasteners or by welds spaced max 24 in. (610 mm) OC. Al. Light Gauge Framing * - Slotted Ceiling Runner — As an alternate to the ceiling runner in Item 2A, slotted ceiling runner to consist of gaiv steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Slotted ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel fasteners or welds spaced max 24 in. (610 mm) OC. BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP -TRK CALIFORNIA EXPANDED METAL PRODUCTS CO — CST CLARKDIETRICH BUILDING SYSTEMS —Type SLT, SLT -H MARINO/WARE, DIV OF WARE INDUSTRIES INC — Type SLT METAL -LITE INC — The System SCAFCO STEEL STUD MANUFACTURING CO TELLING INDUSTRIES L L C — True- Action Deflection Track Ln O O 0 3 x Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. Hilt! Firesto Systems January 11, 2013 P Y Page:1 of 2 A2. Light Gauge Framing * - Vertical Deflection Ceiling Runner — As an alternate to the ceiling runners in Item 2A and 2A1, vertical deflection ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened within runner. Slotted clips provided with step bushings for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 213). Vertical deflection ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel fasteners or welds spaced max 24 in. (610 mm) OC. THE STEEL NETWORK INC — VertiTrack VTD250, VTD362, VTD400, VTD600 and VTD800 A3. Light Gauge Framing * - Notched Ceiling Runner —As an alternate to the ceiling runners in Items 2A through 2A3, notched ceiling runners to consist of C- shaped galy steel channel with notched return flanges sized to accommodate steel studs (Item 2B). Notched ceiling runner installed perpendicular to direction of fluted steel deck and secured to valleys with steel fasteners or welds spaced max 24 in. (610 mm) OC. OLMAR SUPPLY INC — Type SCR B. Studs — Steel studs to be min 2 -1/2 in. (64 mm) wide. Studs cut 112 to 3/4 in. (13 to 19 mm) less in length than assembly height with bottom nesting in and resting on floor runner and with top nesting in ceiling runner without attachment. When slotted ceiling runner (Item 2A1) is used, steel studs secured to slotted ceiling runner with No. 8 by 112 in. (13 mm) long wafer head steel screws at midheight of slot on each side of wall. When vertical deflection ceiling runner (Item 2A2) is used, steel studs secured to slotted vertical deflection clips, through the bushings, with steel screws at midheight of each slot. Stud spacing not to exceed 24 in. (610 mm) OC. C. Gypsum Board* — For 1 hr assembly, one layer of 5/8 in. (16 mm) thick gypsum board is required in the individual Wall and Partition Design. For 2 hr assembly, two layers of 518 in. (16 mm) thick gypsum board is required in the individual Wall and Partition Design. For both hourly ratings, a nominal 3/4 in. (19 mm) gap shall be maintained between the top of the gypsum board and the bottom surface of the steel floor units and the top row of screws shall be installed into the studs 3 in. (76 mm) below the valleys of the steel floor units. The hourly rating of the joint system is dependent on the hourly fire rating of the wall. 3. Joint System — Max separation between bottom of floor or roof and top of wall is 314 in. (19 mm). The joint system is designed to accommodate a max 33 percent compression or extension from its installed width. The joint system consists of a packing material and a fill material between the top of the gypsum board and the bottom of the floor or roof, as follows: A. Forming Material* — Nom 4 pcf (64 kg /m3) mineral wool batt insulation, cut to the shape of the fluted deck, approx 20 percent larger than the area of the flutes and compressed into the flutes of the steel deck flutes above the ceiling runner. The mineral wool insulation is to project beyond each side of the ceiling runner, recessed 112 in. (13 mm) from both wall surfaces . For 2 hr assembly, an additional 1 -112 in. (38 mm) thick by 3/4 in. (19 mm) wide sections of mineral wool batt insulation compressed 50 percent and installed cut edge first to fill the 314 in. (19 mm) gap between the top of gypsum board and bottom of the steel deck. The forming material shall be recessed 1/2 in. (13 mm) from each side of the wall. ROCK WOOL MANUFACTURING CO — Delta Board ROXUL INC — SAFE THERMAFIBER INC — Type SAF Al. Forming Material* —Plugs — (Optional, Not Shown) - Preformed mineral wool plugs, formed to the shape of the fluted floor units, friction fit to completely fill the flutes above the ceiling channel. The plugs shall project beyond each side of the ceiling runner and shall be recessed 112 in. (13 mm) from both wall surfaces. Additional forming material, described in Item 3A, to be used in conjunction with the plugs to fill the gap between the top of gypsum board and bottom of steel deck. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP777 Speed Plugs B. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material installed on each side of the wall in the flutes of the steel deck and between the top of the gypsum board and the bottom of the steel deck, flush with each surface of the wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP606 Flexible Firestop Sealant *Bearing the UL Classification Mark r '71 ="n HIM Firestop Systems Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 11, 2013 0 2 of 2 *TENMAT Technical Product Specifications MODEL FF130 -2x2 ZT MODEL FF130 -2x4 �T 4' 2' - 5l t - - - -- - - - - - - - - - - - - - - - - - - - - - r + 1 N•IS Model Inside Outside Outside Number Height Width Length FF130 -2x2 5" 27° 29° FF130 -2x4 5" 28" 52" Performance For Use: • UL Classified to maintain the fire rating (1 hour) for the following fire -rated assemblies: A2O2, D2O3, D216, D219, G2O5, G2O8, G218, G252, G255, G256, 13262,13264,3201, 3202, LOO6, L2O1, L2O2, L2O6, L2O9, L21O, P2O2, P2O4, P2O6, P2O7, P21O, P211, P213, P214,P216, P225, P227, P228, P229, us P23O, P231, P235, P238, L= P242, P246, P25O, P251, UK P254, P255, P259, P26O, P261, P264, P265, P267, CLASSIFIED FOR FIRE RESISTANCE P268, P269 FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY General Information Benefits: • 60 minute protection. • Fits most popular fluorescent fixtures. • Suitable for lay -in tile ceilings. • Lightweight (approx. 5 and 10 lbs). • Easy Installation - can be fitted in seconds - no screws, drilling or additional sealant required. • Enhances the acoustic protection of the ceiling. • Reduces heat loss through the fixture. • Maintenance free. • Cable entry points can be made anywhere on the top and sides for ease of wiring of the fixture. Manufactured By Tenmat Inc 23 Copper Drive Newport, DE 19804 Phone: (302) 633 -6600 Fax: (302) 633 -6838 Email: info @tenmatusa.com www.tenmatusa.com 2661 17th Street 2270 Hancock Expressway Denver, CO 80211 Colorado Springs, CO 80910 P 303.455.1012 P 719.227.9997 www.thelighfingagency.com Submittal Package VAIL CASCADE LAUNDRY REMODEL NOVEMBER 20, 2013 WHEN PRINTING THE ATTACHED PDF FILE YOU WILL NEED TO CHANGE ONE OPTION ON YOUR PRINT WINDOW, AFTER SELECTING PRINT, ON THE BOTTOM LEFT IN THE FIRST SCREEN THERE SHOULD BE A "PRINT WHAT" PULL -DOWN MENU. BE SURE THAT THE SELECTION YOU HAVE IN THAT PULL -DOWN MENU READS "DOCUMENT\ AND COMMENTS /EDITS" THIS WILL ALLOW YOU TO PRINT AND VIEW THE EDITS TLA HAS MADE TO THE FOLLOWING DOCUMENT TRANSMITTAL TO ALL PHASE - GLENWOOD SPRINGS DATE NOVEMBER 20, 2013 ATTN AARON ELAM RE VAIL CASCADE LAUNDRY REMODEL WE ARE SENDING YOU: Attached Change of Order Copy of Letter x Cutsheets Plans Prints Samples Shop Drawings Specifications Under Separate Cover COPIES DATE DESCRIPTION 1PDF 11.20.13 Submittals SWITCHING OPTIONS: CEILING TYPE: SUSPENSION LENGTHS: THESE ARE TRANSMITTED: (AS CHECKED BELOW) x For Approval Approved as submitted Resubmit For your use Approved as noted Submit _ Record Only Return corrected prints For review and comment Other FOR BIDS DUE 20 REMARKS: copies for approval copies for distribution IF SUBMITTALS ARE "FOR APPROVAL" AND MATERIAL IS RELEASED WITHOUT THE RETURN OF ONE COMPLETE SET OF APPROVED DRAWINGS, THIS WILL BE DEEMED YOUR WAIVER OF APPROVAL. * * *VnNTRA(TnR Tn VFRIFV - * ** COPY TO FILE BY: LEXI MAZZILLO IF ENCLOSURES ARE NOT AS NOTED, PLEASE NOTIFY US AT ONCE 0 THE LIGHTING AGENCY VOLTAGE: ROW INFORMATION: COLORS/FINISHES: SWITCHING OPTIONS: CEILING TYPE: SUSPENSION LENGTHS: SPECIFIC DIMMING BALLASTS if required) OTHER: COPY TO FILE BY: LEXI MAZZILLO IF ENCLOSURES ARE NOT AS NOTED, PLEASE NOTIFY US AT ONCE 0 THE LIGHTING AGENCY Submitting Agency: 2SP8 G 2 32 FW Al2 MVOLT GEB101S "1"11 �t� Agency Description: PWS1836 LP835 """ o- 7:a.= aaoo Pro I ect VAIL CASCADE LAUNDRY REMODEL Notes: fA LIMMVIA L /GHT /NG"` FEATURES & SPECIFICATIONS INTENDED USE — Specification premium, highperformance , staticTBluminaires provide general illumina- tionforrecessedapplications, ideal forrestrictedplenum spaces.Certain airbomecontaminantscandiminish integrity of acrylic. Click here for Acrylic Environmental Compatibility table for suitable uses ATTRIBUTES — Designed exclusively for use with T8 lamps, electronic ballasts and sockets. CONSTRUCTION — Smooth hemmed sides and smooth, inward formed end flanges for safe handling. Lighter weight fixture allows safe, easy installation. Standard steel doorframe has superior structural integrity with premium extruded appearance and precision flush mitered corners. Steel door allows easy lens replacement without frame disassembly (for lenses up to . 156" thick). Powder - painted, steel latches provide easy, secure door closure. Superior mechanical light seal requires nofoam gasketing.lmegral T -bar dips securefixturetoT- barsystem. Housing forted from cold -rolled steel. Acrylic shielding material 100% UV stabilized. No asbestos is used in this product US PATENTS: 6,210,025; 6,231,213; 6,213,625; 2,288,471. FINISH — Five -stage Iron- phosphate pretreatment ensures superior paint adhesion and rust resistance. Painted parts finished with highly reflective matte white enamel. OPTICAL— Al2 lens features reverse apex technology for superior lamp obscuration and improved visual comfort. ELECTRICAL — Standard ballast is electronic, thermally protected, resetting, Class P, HPF, non -PC8, UL Listed, CSA certified ballast universal voltage and sound rated A. Luminaire is suitable for damp locations. AWM, TIN or THHN wire used throughout, rated for required temperatures. LISTING — Standard: UL Optional: Canada — CSA or cUL; Mexico — NOM. WARRANTY —1 -year limited warranty. Complete warranty terms located at www. acui( yhrands .com /CustomerResources/Terms and conditions asox Note: Specifications subject to change without notice. Type: A CONTRACTOR TO VERIFY: Voltage: Row Information: Colors/ Finishes: Switching Options: Ceiling Type: Suspension Lengths: Specific Dimming Ballasts if required): Other specification Premium T8 Troffer SP8 2'X4' 2, 3,4or6Lamps T8 ® o jpeciArodons Length: 48 (1218) D Width: 24 (609) Depth: 3- 11116 (94) L Weight: 22lbs (9.9 kg) All dimensionsare inches (millimeters). s • s ' 'f For shortest lead times, configure products using bolded options. Example: 2SP8G332Al2MVOLTI/3GE61OIS 2SP8 G 2 32 Pot Al2 NVOLT GEBIOIS PNS1836 LP835 2SP8 2'wide G Gdd 32 32WT8(48 ") omwim (blank) Flush steel, i12 item 120 MEN= 1/4 One 4-lamp ballast Al2 I F Overlapping 3 white a uc 277 1/3 One 3-lamp ballast flanged 4 FN Flush aluminum, natural A12125 912 item a is 125" 347' GEB101S Electronic ballast <10%THD, instant 6 thick MvOLP start Not FM Flush aluminum, matte black RA125 1'12 pattern others GEB10PS Electronic ballast <10%THD, included FW Flush aluminum, acrylic.125" available programmed start white thick, reverse GEBIORS Electronic ballast <10%THO, rapid apex start RN Regressed aluminum, A19 il9ppaattern EL Emergency battery pack (nominal 300 natural acrylic .i56" thick lumens) RM R ressed A15 /15pattem EL14 Emergency battery pack (nominal 1400 lumens) aluminum, matte blade acr ylic, �" thick GLR Internal fast-blow fuse' RW Regressed KIS 1/2"x 1/2"x GMF Intemalslow- blowfuse' awhitenum, 1/2 "elastic LST Tandem -wired fixture pairs (shared cube ouver, ballasts silver PC2S 1 -i/2" x 1.1/2" PWS1836 6' ewire, 3/8" dia.,18-gauge, t circuit z 1" plastic cube PWS1846 6' prewire, 3/8" dia.,18- gauge, 2 circuit louver, silverw/ flange LP735 Lamped, 700- series, 3500K K35 3/4"x3/4"x LP_ Lamped, specify lamp type and color 112" clastic JP Palletized and stretch- wrapped with - c ouver, silver out individualcartorus;96 trim only CSA (SA Certified NOM NOM Certified CP Chicago Plenum NOTE: 1. Not available withGEBiOPS. 2. MVOU standard for 120- 277V applications, 50. hzoperat Ion. Some options require voltage specified. 3. Mug Wecify voltage 120or277V. FLUORESCENT: SP8 -2x: Submitting Agency: Tho LWMng Agency r > io.ay.taoos F -not > ootao SP8 2'x4' Static T8 Troffer Description: 2SP8 G 2 32 FW Al2 MVOLT GEB101S Type' PWS1836 LP835 Project VAIL CASCADE LAUNDRY REMODEL Notes: MOUNTING DATA Campwous row mounting dexged units requires CRE and CRM trim options (see Options). G Lay -in Grid (exposed or concealed grid) F Overlapping Flanged Trim with swing -gate hangers DIMENSIONS 4-778 L �- 124 -� 0 31/H8 (94) 24 (eos) 24 (608) T18 (84) 1Z8 NOTE: O O I O O 311118 1 Aecanmended rouglrindimerdalsf af- trim fiaturet 24"x48'. (Tdetante is +l /4' -0".J Swing -gate rage l- 3/16" (>K) to 3- 15116 ". Swing-gate span 23 -3/8" to 26 lg-ga 11/16". Fixture swhte points require additional 9/16" over nominal & re height 24 PHOTOMETRICS Calculated usingthennal CHO method in accordaoce with IESNA LM41 procedure. Roo re8ett8nces are 20%. Lamp con6gwadons shown we typical. Fur photometric data on these and other configurations awdaMe upon request. 2SP8 2 32 Al2• Report LTL 7525 Lumens per lamp - 2850- Lum. eff.- 85.5% Will (along) 1.3 (across) 1.4 Coefficient of Utilization Ceiling 8096 70% SO% 0 102 102 101 99 99 99 95 95 95 1 94 90 87 92 88 85 85 82 80 2 86 80 74 84 78 73 75 71 68 3 79 71 64 77 70 64 67 62 58 4 73 63 56 71 62 56 60 55 50 5 67 57 50 66 56 49 54 48 44 6 61 52 44 61 51 44 49 43 39 7 58 47 40 57 46 40 45 39 34 8 54 43 36 53 42 36 41 35 31 9 51 39 33 49 39 33 38 32 28 10 47 36 30 46 36 30 35 29 25 Zonal Lumens Summary 7- Inman W %Rvh.. 10 47 36 30 46 0 -30 1541 27.0 31.6 25 Zonal Lumens Summary 7- h- %I amp 96pma 0-40 2571 45.1 52.7 0-30 2319 27.1 0.60 4192 73.5 86.0 86.3 0-40 3833 44.8 0 -90 4874 85.5 100.0 100.0 0.60 6164 90 -180 0 0 0 0 0 -90 0- 180 4874 85.5 100.0 100.0 2SP83 3I All 2* Report LTL 7492 Lumens per lamp -2850 - Lum. eff. -83.6% S/MH (along) 1.3 (across) 1.4 Coefficient of Utilization Wig 30% 70% 5096 0 100 100 100 97 97 97 93 93 93 1 92 88 85 90 86 83 83 80 78 2 84 78 73 82 77 72 74 70 66 3 78 70 63 76 68 62 66 61 57 4 72 62 55 70 61 55 59 54 49 5 66 56 49 64 55 49 53 48 43 6 61 51 44 60 50 43 49 43 38 7 57 46 39 56 46 39 44 38 34 8 53 42 36 52 42 35 41 35 31 9 50 39 32 49 38 32 38 32 28 10 47 36 30 46 36 29 35 29 25 Zonal Lumens Summary 7- h- %I amp 96pma 0 -40 4999 43.8 0-30 2319 27.1 32.4 0.60 8017 70.3 86.3 0-40 3833 44.8 53.6 9292 81.5 100.0 0.60 6164 72.1 90 -180 86.2 0 0 0 -90 7147 83.6 9292 100.0 100.0 90 -180 0 0 0 0.180 7147 83.6 100.0 fA L/THON /A L /dGHT/ MO' An I;4caityE3rarOs Corry"iy 2SP8 432 Al2" Report LT17526 Lumens per lamp -2850 - Lum. off.- 81.5% Will (along) 1.2 (actress) 1.4 Coefficient of Utilization Ceiling 80% 70% 5096 0 97 97 97 95 95 95 91 91 91 1 90 86 83 87 84 81 81 78 76 2 82 76 71 80 75 70 72 68 65 3 76 68 62 74 67 61 64 59 55 4 70 61 54 68 60 53 58 52 48 5 64 55 48 63 54 47 52 46 42 6 60 50 43 58 49 42 47 42 37 7 56 45 38 54 44 38 43 37 33 8 52 41 35 51 41 34 40 34 30 9 48 38 32 47 38 31 37 31 27 10 46 35 29 44 35 29 34 28 25 Zonal Lumens Summary Inro Iim 961 wop %nrnm 0 -30 3029 26.6 32.6 0 -40 4999 43.8 53.8 0.60 8017 70.3 86.3 0 -90 9292 81.5 100.0 90 -180 0 0 0 0 -180 9292 81.5 100.0 • With reverse apex lens SP8 -2 %4 FLUORESCENT: One llthonia Way Conyers, GA 30012 Phone: 800315 -0963 Far.: 770 -981 -8191 www.litho.iia.com 0999.2012 Acuity Brands Lighting, Inc. All rights reserved. Rev. 05/16/12 Submitting Agency: The L% tin9 Agency P'929.339.!i94T F- 9i4.239..l�900 Description: LB 2 32 MVOLT GE1310IS LP835 Project: VAIL CASCADE LAUNDRY REMODEL Notes: f, LIMMMIA LIMMMM" FEATURES & SPECIFICATIONS INTENDED USE — For applications that require the clean appearance of a low- profile, brightness - controlled wraparound. Provides broad distribution of light for offices, schools and corridors. Certain airborne contaminants an diminish integrityofacrylic.Click hereforAcrjcEnvironmental Compatibility table forsuitable uses Attributes: Curved prismatic diffuser with linear side prisms minimize lamp Image and provides high angle brightness control. Luminous end plates soften appearance for improved aesthetics. CONSTRUCTION —Metal parts are dieformed from code -gauge steel. Prismatic diffuser is 100% acrylic with sonically welded luminous ends. Continuous side flanges on fixture body provide light trap and continuous diffuser support to prevent accidental opening and simplify maintenance. Finish: Five stage iron - phosphate pretreatment assure superior paint adhesion and rust resistance. Painted parts finished with high- gloss, high - reflectivity baked white polyester enamel (law YOq. ELECTRICAL— Thermally - protected, resetting, Class P, HPF, non -PCB, UL Listed, CSA Certified ballast is standard. Luminaire is suitable for damp locations. AWM, TFN or THHN wire used throughout, rated for required temperatures. UL /CSA listed ballast disconnect w /strain relief and leads provided standard. LISTINGS — UL Listed (standard). Optional: Canada CSA or C -UL. Mexico NOM. WARRANTY —1 -year limited warranty. Complete warranty terms located at www.acuitybr,inds,(oml(uitomerResources/Terms and condition< asox Note: Specifications subject to change without notice. Saecffications T8 Length: 48 (121.9) T5 Length: 46 -1/2 (118.1) Width: 15 -1/2 (39.4) Height: 2 -15/16 (7.5) All dimensions are Inches (centimeters) unless otherwise indicated. Type: B CONTRACTOR TO VERIFY: Voltage: Row Information: Colors/ Finishes: Switching Options: Ceiling Type: Suspension Lengths: Specific Dimming Ballasts Par required): Other: 17 17W T8 (14 ") 32 32WT8(48 ") 120 277 *!f34.0) 3 -3/8 1a 1s 2(7518 3.7 217518 3 -5/8 19.21 15 -1n 139.4) Low-Profile Wraparound �J T5 and T8 WIDE BODY 4' length 2 or 4lamps 13 -3/8 134.61 7 1 . 2 -15/16 ?1 (7.5) 3 -5/8 3 19.21 19.21 15 -1R (39.4) 13 -3/8 13 -3/8 (34.0) 134.0) _ T __.._........._- --- ..._.... — - t• is 2.15/16 _ L2�L 1361 2 -15/16 4.0 17.51 t 11.51 --'- 2 -1/2 -1 __ -- 4.3/4 ............ .__. 4.3/4....... 16.41 16.4) z -1n_ 2.1n 18.41 16.41 4 -314 4.314_; (121) 021) ! (121) 15 -1/2 (121) 15 -1n (39.4) (39.4) ' ' s ' I s ' A For shortest lead times, configure product using standard options (shown in bold). Example: LB 4 32 MVOLT GEB101S LB 2 32 MVOLT GEB101S LP835 :2J 4 17 17W T8 (14 ") 32 32WT8(48 ") 120 277 1/4 One, four -lamp ballast FGEBIOIS Electronic ballast,: 510%THD,instants[art LB 41am s, 15 -1/2 "wide All 2 lamps, l5 -1/2 "wide For tandem double - length unit, add Not 14T5 14WT5(22- 1/2 ")' GEBIOPS Electronic ballast, sl 0% THD, programmed start prefix T. Example: Tl6 included. 28T5 28W TS (46-1/2") MYOLT EL Emergency battery pack (nominal 300 lumens, see Life Safety Section) 54T5HO 54WT5HO(46- 1/2 ")2 Others GLR Internal fast -blow fuse' available. GMF Internal slow -blow fuse' CSA Listed and labeled to comply with Canadian Standards mss - SQ_ Swivel -stem hanger (specify in 2" increments). 16 Ceiling spacer ( adjusts from 1 -112" to 2 -1/2" from ceiling). Notes 1 Not available in4lamp. 2 T5HOonlyavailablein two- lampconfiguration. 3 Must specifyvoltage. FLUORESCENT LEIV Submitting Agency: Description: LB 2 32 MVOLT GEB101S LP835 The it-ilghtUrlig Agency Project VAIL CASCADE LAUNDRY REMODEL ....-.... Notes: P- 710.227.0007 F— T10.2ZT -0900 LB Low - Profile Wraparound, Wide Body MOUNTING DATA For unit or row installation, surface or stem mounting. Stem mounting not available on TLB units. Individual installation —Two single -stem hangers required. Row Installation —One hanger per fixture plus one per row required. See ACCESSORIES below for hanging devices. A =1/4 x 112 (.635 x 1.27) Oval Hole B = 7/8 (2.22) Dia. K.O. C =11/16 (1.74) Dia. K.O. Type: B DIMENSIONS All dimensions are inches (centimeters) unless otherwise indicated. Specifications subject to change without notice. PNOTOMETRICS Calculated using the zonal cavity method in accordance with IESNA LM41 procedure. Floor reflectances are 20 %. Lamp configurations shown are typical. Full photometric data on these and other configurations available upon request. LR 4 32 Report In 5614 - Lumens per lamp = 2900 S/MH (along) 1.2 (aaoss)1.3 Coeffident of Utilization cea:g Lumens 80% %Fixture 0.30 70% 20s 17.0 s0% 3914 0% W41170% 50% 30% 70% 50% 30% 50% 30% 10%i0% 6499 56.0 0 89 89 89 86 86 86 80 80 80 68 1 81 78 75 78 75 73 71 69 67 58 2 75 69 64 72 67 63 63 59 56 50 3 69 62 56 66 60 55 57 52 49 43 4 63 55 49 61 54 48 51 46 42 38 5 58 49 43 56 48 42 45 40 36 33 6 54 44 38 52 43 37 41 36 32 29 7 50 40 34 48 39 33 37 32 28 25 8 46 36 30 44 35 29 33 28 24 12 9 42 32 26 41 31 26 30 25 21 19 10 39 29 23 38 29 23 27 22 19 16 Zonal Lumens Summary Zone Lumens %Lamp %Fixture 0.30 2376 20s 17.0 0.40 3914 33.7 44.1 0.60 6499 56.0 73.7 0.90 7883 68.0 89.4 90.180 931 8.0 10.6 0- 180 8815 76.0 100.0 fA LIrmamA L/GHT /NG- LB -W An"Wulfyf lrand, Company FLUORESCENT: One LRlwnia Way, Conyers, GA 30012 Phone: 800 -858 -7763 Fax: 770 - 929 -8789 www.hfllonia,com c; 1999 -2013 Acuity Brands Lighting, Inc. All rights reserved. Rev. 02/06/13