Loading...
HomeMy WebLinkAboutB13-0508 plans approvedCOVER INTERNATIONAL RESIDENTIAL CODE 2012 PROJECT SUMMARY: Zoning: SINGLE-FAMILY RESIDENCE Code: CROSS RENOVATION PERMIT SET 126 FOREST RD. #W VAIL, CO 81657 GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN IBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. DRAWING INDEX Detail Area Reference Elevation Reference Section Cut Reference Large Area Detail Reference 12/31/1999 Material Tag Revision Symbol Detail Cut Reference Grid Bubble Revision Cloud Elevation Symbol SYMBOLS: TYPE R DIV. 3 Occupancy Classification: ARCHITECT: K.H. WEBB ARCHITECTS P.C. 710 W. LIONSHEAD CIRCLE, UNIT A VAIL, CO 81657 PH. 970.477.2990 CONTACTS: KYLE H. WEBB DEBRA MONROE PROJECT TEAM: A monitored fire alarm system is required and must comply with NFPA 72(2002) and VFES standards TYPE V Construction Type: STRUCTURAL ENGINEER: MONROE & NEWELL ENGINEERS, INC. PH. 970.949.7768 CONTACT: HANNES SPAEH PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 GENERAL CONTRACTOR: TRANSWEST CONSTRUCTION, LLC. PO BOX 8812 AVON, CO 81620 PH. 970.376.6543 CONTACTS: MIKE SCRIVENS KYLE HOILAND OWNER CONTACT: RON BYRNE PH. 970.476.1987 ARCHITECTURAL A 001 1/8" = 1'0"GRFA CALCULATIONS A 100 1/8" = 1'0"SITE PLAN - PROPOSED A 101 1/4" = 1'0"GARAGE LEVEL PLAN - EXISTING/PROPOSED A 102 1/4" = 1'0"NEW BEDROOM LEVEL PLAN - EXISTING/PROPOSED A 103 1/4" = 1'0"MASTER LEVEL PLAN - EXISTING/PROPOSED A 104 1/4" = 1'0"LIVING LEVEL PLAN - EXISTING/PROPOSED A 105 1/4" = 1'0"LOFT PLAN - EXISTING/PROPOSED A 106 1/4" = 1'0"ROOF PLAN - EXISTING/PROPOSED A 107 1/4" = 1'0"GARAGE LEVEL REFLECTED CEILING PLAN A 108 1/4" = 1'0"GUEST LEVEL REFLECTED CEILING PLAN A 109 1/4" = 1'0"MASTER LEVEL REFLECTED CEILING PLAN A 110 1/4" = 1'0"LIVING LEVEL REFLECTED CEILING PLAN A 111 1/4" = 1'0"LOFT LEVEL REFLECTED CEILING PLAN A 200 1/4" = 1'0"WEST ELEVATION - EXISTING/PROPOSED A 201 1/4" = 1'0"NORTH ELEVATION - EXISTING A 202 1/4" = 1'0"NORTH ELEVATION - PROPOSED A 203 1/4" = 1'0"SOUTHWEST ELEVATION - EXISTING/PROPOSED A 500 SCALE VARIES DETAILS CIVIL 1:10 SURVEY Received By Carolyn Godfrey at 9:58 am, Dec 13, 2013 B13-0508 CR1 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) Reviewed for Code Compliance Code: 2012 International Building Code (IBC) NEW AREA: 840 SQ. FT. NEW GRFA GARAGE NEW AREA: 67 SQ. FT. BASEMENT DEDUCTION (see SF-1 in Read Residence Remodel) 881 * .19 = 159 sq. ft. TOTAL AREA: 839 SQ. FT. MECH. <5'HT. EXTG GRFA NEW GRFA NEW AREA: 170 SQ. FT. TOTAL AREA: 984 SQ. FT. EXTG GRFA NEW GRFA NEW AREA: 171 SQ. FT. TOTAL AREA: 982 SQ. FT. EXTG GRFA NEW GRFA TOTAL AREA: 318 SQ. FT. OPEN TO BELOW, <16'H EXTG GRFA SEC. (40%) PRIM. ( 60%) GARAGE LEVEL 839 1016 NEW BEDROOM 792 MASTER 984 812 LIVING 982 1309 LOFT 318 755 NET SF 3,915 3,892 GARAGE CR.: -600 -600 BSMNT DED.: -680 -823 TOTAL GRFA:2,635 sf 2,469 sf (5,104) GRFA CALCULATION: ( SEE SF-1 READ RESIDENCE SET FOR PRIMARY EXHIBITS) PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 1 scale 1/8"=1'-0" GARAGE LEVEL GRFA 2 scale 1/8"=1'-0" NEW BEDROOM GRFA 3 scale 1/8"=1'-0" MASTER GRFA 4 scale 1/8"=1'-0" LIVING GRFA5scale 1/8"=1'-0" LOFT GRFA Reviewed for Code Compliance Code: 2012 International Building Code (IBC) LOT 6 LOT 4 FOUND PLAIN #5 REBAR FOREST ROAD (50' R.O.W.) SEWER MANHOLE 2' X 2' ROCK LIGHT POST 25 . 0 0 ' ACCESS EASMENT RECORDED BOOK 570, PAGE 202 SEWER MANHOLE T.O.W. ENTRYENTRY GARAGE ENTRY ENTRY UPPER ENTRY LOT 3 FLAGSTONE PATIO WINDOW WELLFLAGSTONE WALK FLAGSTONE PATIO PATIO/SPA FACE OF ROCK OUTCROP 10'UTILITY EASEMENT UTILITY EASEM E N T (NO WIDTH DI M E N S I O N O N P L A T ) NEW GARAGE WALL NEW ENTRY NEW SNOWMELTED DRIVE W/ PAVERS PARKINGSPOT PARKING SPOT PARKING SPOT PARKING SPOT TO SLAB 97'-8" DOG RUN 9' x 19' 45.3 46.9 TREE TO BE REPLACED 9'X19' 9' x 19' OLD GARAGE WALL 12 % 1 2 % NO CH A N G E 12 % DR I V E TRENCH DRAIN LINE OF SITE DISTURBANCE T.O.W. 11' - 0 3 8" T.O.W. T.O.W. NEW 3' BOULDER RETAINING WALL DRIVEWAY CENTERLINE 8% 8% DRIVEWAY PERIMETER B.O.W. B.O.W. B.O.W. EXISTING WALL TO REMAIN B.O.W. T.O.W. T.O.W.T.O.W. T.O.W. T.O.W. 20 ' - 0 " 15 ' - 0 " 15'-0" LINE OF SETBACK 15 ' S E T B A C K 15' SETBACK 20 ' S E T B A C K LIVING LEVEL DECK ABOVE TREE TO BE REPLACED T.O.W. T.O.W. B.O.W. 7.07" rise - 14 steps 1 scale 1/8"=1'-0" SITE PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) GARAGE 100 TO SLAB 97'-8" TYP. @ PERIMETER TO SLAB 97'-8" ELEV. TO LANDING 101'- 4" MECH.ROOM 101 MUD 102 RISE - 6 @ 7.36" SKI STORAGE SKI STORAGE B E N C H / S K I B O O T S B E L O W C U B B I E S A B O V E FULL-SIZED WASHER AND DRYER LAUNDRY 103 STAIR 104 EXISTING GARAGE WALL NEW GARAGE WALL 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: 1 100 1 101 1 103 2 100 1 104 6" PIT RISE - 9 @ 7.4" T.O. SLAB 98'-3 1/2" CEILING HEIGHT 4'-3 15/16" 3'-0" 1 9 ' - 3 12 " 9' - 8 " 4'- 1 1 78" 312" 4'- 9 " 5'-8 " 3'- 2 1 2" 3'- 8 12" 10 ' - 8 38" 31 2" 4' - 9 7 8" 3 12" 3 1 2" 3'-7 1 4 " 3 12 " 5'-8 38" 8"6" 19'- 1 0 1 8" TILE CON C R E T E SHELVES H A N G I N G TILE WD , 2 A 3 0 0 STEP T.O. SLAB 98'-3 1/2" NEW GARAGE DOOR W/ WINDOWS BOTTOM OF 1ST STAIR 98'-9 5/8" 3 12" HAN G I N G 8" 512" 7.07" RISE - 14 STEPS OPEN RAIL THIN VENEER 4" MAX THIN VENEER 4" MAX VENEER 6" FLOOR PLAN NOTES: E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS. PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER WHERE IS SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE. 1 1 TYPE X GYP UNDER STAIRS, TYP. EXTG. STAIR RAILING TO REMAIN GARAGE XXX TO SLAB 102'-0" TYP. @ PERIMETER TO SLAB 102'-6" TO SLAB 102'-0" ELEV. TO LANDING 107'-4 1/2" CRAWL SPACE 5'-0" HEAD HEIGHT T.O. GYPCRETE 110'-6" UP U P 1 A201 2 A200 2 A203 1 scale 1/4"=1'-0" GARAGE LEVEL FLOOR PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 2 scale 1/4"=1'-0" GARAGE LEVEL FLOOR PLAN - EXISTING Reviewed for Code Compliance Code: 2012 International Building Code (IBC) JR. MASTER BEDROOM 205 GUEST 202 T.O. STONE 111'-5 5/8" T.O. FINISH FLOOR 106'-10 5/8" U P TO SLAB 97-8" ELEV. LIVING DECK ABOVE OPEN RAIL, NEW DECK BENCH GALLERY 206 G. BATH 200 DN ENTRY PORCH RISE - 8@ 6.9" TV 7.07" rise - 14 steps B U I L T - I N W A R D R O B E TV NOOK CLOSET 201 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: JR. BATH 203 9 1 200 1 202 1 201 2 206 1 205 1 203 1 204 1 206JR. W.C. 204 RISE - 8@ 6.9" EXISTING RETAINING WALL TO REMAIN312" 3'-8 12" 31 2" 12'-8 12 " 5 12 " 2'- 0 1 4" 6'-2 12" 8'- 1 1 8" 2'-1 58" 9'-4 1 4 " 8'-9 5 8" 3' - 0 " 3'-1" 312" 3 1 2" 7'-11 1 4" 6'- 7 1 4" 3 12" 14 ' - 3 " 1' - 0 " 2'- 1 0 78" 3 1 2" 4' - 8 12 " 1'-1 1 58" 5'-1 0 3 4" 3'-0 "31 2" 3'- 0 1 8" 21 ' - 1 1 7 8" C P T . W D , CP T . WD , CP T . TIL E CP T . TIL E 2A 3 0 0 BOTTOM OF 1ST STAIR 98'-9 5/8" TIERED PLANTERS TIERED PLANTERS TIERED PLANTERS GARAGE WALL BELOW THIN VENEER 4" MAX THIN VENEER 4" MAX VENEER 6" CLOSET 207 38 SQ. FT. 1 207 1' SILL FLOOR PLAN NOTES: E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS. PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER WHERE IS SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE. 1 E E 4'-0 3 4" 3'- 8 12" 31 2" 12 ' - 3 5 8" SLOPING NEW COL., RE:STRUCT 1 1 scale 1/4"=1'-0" NEW BEDROOM LEVEL FLOOR PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) MASTER SUITE 303 MASTER BATH 304 GUEST 301 T.O. STONE 121'-0" T.O. GYPCRETE 116'-0" UP ELEV. DECK ABOVE NEW DECK BELOW ST A C K A B L E W/ D IN B U I L T - I N C A B I N E T CLOSET 306 MASTER W.C. 305 NEW AREA: 170 SQ. FT. VIEWVIEW DNEXISTING BATH TO REMAIN EXISTING CLOSET TO REMAIN 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: F.P. WARDROBE TV CLOSET #2 302 1 307 G.BATH 300 HALLWAY#3 307 1 301 1 303 1 302 1 304 1 305 1 306 EXISTING BAY WINDOWS TO REMAIN RISE - 8@ 7.25" RISE - 8@ 7.25" SLAB ON GRADE NEW FRENCH BALCONY, RAILING TO MATCH EXTG HOUSE RAILINGS BENCH SLOT DRAIN SLOT DRAIN 9'-5" 31 2" 4'-6 14" 31 2" 1 3 ' - 6 14" 5 12" 2' - 1 0 1 4 " 3'-4 3 8 " 8'-10 1 8 " 2'- 8 58" 4'- 8 1 8" 4'-8 1 8" 11'- 1 18" 6'- 1 3 4" 23'-6" 4'- 2 " 6'-5 1 2" 3'- 9 18" 31 2" 12 ' - 7 18" 512" 312"4'-2 12" 5 12" 6'- 9 1 2" 512" 1 3 ' - 8 7 8" 312" 2'-0" 3'-6" 2'-4 1 8 " 1' - 2 " 51 2 " 9'-0 1 8 " 8'- 1 1 4" 51 2" 3'- 4 1 4"31 2" 1'- 6 " 5' - 8 12" 3 1 2 " 51 2" 15'- 1 3 4" 1'- 6 " 312" 11 ' - 5 1 2" 51 2" TV W/ HYD. ARM SOAP NICHE SOAP NICHE C P T . W D . CPT. TI L E CPT. TI L E CPT . WD. CP T . TIL E 2A 3 0 0 1 1 EXTG RAILING TO REMAIN, TYP. FLOOR PLAN NOTES: E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS. PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER WHERE IT SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE. TYP. EXTERIOR WALL CONSTRUCTION - WOOD: -1x V-GROOVE CEDAR SIDING, STAINED TO MATCH EXTG. -WATER REPELLENT BARRIER OR 30# FELT -1/2" PLYWOOD SHEATHING -2x FRAMING -R-21 MIN BATT INSULATION -VAPOR BARRIER AT INTERIOR -5/8" GYPSUM BOARD 1 2 2 2 E L E V . MASTER BEDROOM XXX MASTER BATH XXX CLOSET XXX BEDROOM #2 XXX BATH #2 XXX T.O. STONE 121'-0" T.O. GYPCRETE 116'-0" UP TO SLAB 102'-0" DN DECK ABOVE TOTAL EXISTING AREA: 814 SQ. FT. 1 A200 1 A201 2 A203 4'-9 1 2" 3'- 8 1 2" 1 scale 1/4"=1'-0" MASTER LEVEL FLOOR PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 2 scale 1/4"=1'-0" MASTER LEVEL FLOOR PLAN - EXISTING Reviewed for Code Compliance Code: 2012 International Building Code (IBC) ELEV. LIVING 403 KITCHEN 401 131'-0" T.O. STONE TO STONE 125'-11" T.O. GYPCRETE 126'-0" UP TO STONE 125'-11" DN DECK DECK POWDER 400 NEW TRACK SLIDING 4 PANEL POCKET DOOR 32"X32" "BENTO" FIRE PIT BY PALOFORM, PROVIDE NEW NATURAL GAS QUICK CONNECT AS NECESSARY WIRED FOR HOT TUB OUTDOOR LIVING 406 DOG RUN 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: B B Q 9 EXISTING BAY WINDOWS TO REMAIN DINING 402 1 302 HALLWAY#4 405 RISE - 8@ 7.7" EXPOSED STRUCTURAL BEAM ABOVE REFRIGERATOR 9 8" 6'-5 1 2" 4"51 2" 4'-0 " 5 1 2" 134" 4'-1 12" 5'-2 1 2" 5'- 8 34" 14'- 1 " 5'-2 3 8" 7' - 0 " 3 1 2" EXISTING POWDER ROOM TO REMAIN 5'-8 1 4" 1" 4'-8 5 8" 1" 5'-3" 18'-4" 5 1 2" INVISIBLE SCREEN - SPLIT FROM MIDDLE BUILT-IN COUNTER BUILT-IN COUNTER GRANITE COUNTERTOPS - DBL THICK EDGE NEW WALNUT FLOORING THROUGHOUT W D . W D . 2A 3 0 0 PO P - U P T V NEW AREA OPEN TO ABOVE RANGE DRY BAR XXX FLOOR PLAN NOTES: E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS. PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER WHERE IT SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE. TYP. EXTERIOR WALL CONSTRUCTION - WOOD: -1x V-GROOVE CEDAR SIDING, STAINED TO MATCH EXTG. -WATER REPELLENT BARRIER OR 30# FELT -1/2" PLYWOOD SHEATHING -2x FRAMING -R-21 MIN BATT INSULATION -VAPOR BARRIER AT INTERIOR -5/8" GYPSUM BOARD 1 16 ' - 7 34" FD FD FD FD FD FD FD FD RELOCATE EXTG FLOOR DRAIN RELOCATE EXTG FLOOR DRAIN PROVIDE NEW 24"x4" OVERFLOW SCUPPER THROUGH WALL DIRECT VENT LINEAR GAS FIRPLACE NEW RANGE W/ DOWNDRAFT EXHAUST THROUGH EXTERIOR WALL NEW RAILING TO MATCH EXTG,1 EXTG RAILING TO REMAIN W5 x 1 6 FILL W-FLANGE WEBS W/ RS RED CEDAR, STAIN SLIMLINE INFRARED PATIO HEATERS BY INFRATECH 8" 3'-7 58" 1 1 1 2" 13'-4" 5'-5 1 2" W5 x 1 6 W8x18 BEAMS OVHD, B.O. BEAM +9'-4", AFF 2 2 2 NEW HOOD LESS THAN 400CFM FLOW RATE, NO MAKE-UP AIR MECHANICAL FLUE ELEV. LIVING XXX KITCHEN XXX POWDER XXX 131'-0" T.O. STONE TO STONE 125'-11" T.O. GYPCRETE 126'-0" UP D/W TO STONE 125'-11" OPEN TO ENTRY BELOW TOTAL EXISTING AREA: 821 SQ. FT. 1 A2001 A201 2 A203 FD FD FD FD FD FD FD FD WALL DRAIN W A L L D R A I N H O T T U B ? REMOVE EXTG. WINDOW RELOCATE EXTG FLOOR DRAIN RELOCATE EXTG FLOOR DRAIN 1 scale 1/4"=1'-0" MAIN LEVEL FLOOR PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS 12.06.13 2 scale 1/4"=1'-0" MAIN LEVEL FLOOR PLAN - EXISTING Reviewed for Code Compliance Code: 2012 International Building Code (IBC) DN LOFT 500 T.O. GYPCRETE 136'-0" T.O. STONE 135'-11" OPEN TO BELOW, <16'H 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING BAY WINDOWS TO REMAIN 1 5011 500 LOFT BATH 501 EXISTING DOOR TO REMAIN 312" 2'- 7 34" 31 2"5 1 2" 3 12 " 1' - 6 " CL O S E T EXISTING LOFT TO REMAIN NEW LOFT BATH LAYOUT. VFY. FIXTURES W/CLIENT 6'-6 " 8'-6 3 4" 6'-7 1 2" 7'- 7 58" 6'-5" 3'-4" 3'-4" 3'-4" 6'-3 1 2" TILE WD. W D . W D . 2 A 3 0 0 NEW RAILING EXTG RAILING TO REMAIN DN LOFT XXX T.O. GYPCRETE 136'-0" T.O. STONE 135'-11" OPEN TO BELOW TOTAL EXISTING AREA: 377 SQ. FT. CL O S E T 1 A200 1 A201 2 A203 1 scale 1/4"=1'-0" LOFT LEVEL FLOOR PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 2 scale 1/4"=1'-0" LOFT LEVEL FLOOR PLAN - EXISTING Reviewed for Code Compliance Code: 2012 International Building Code (IBC) 1 A200 1 A202 1 A203 1'-0 3 4" 2'- 1 1 3 8" 8'- 0 58" 9'- 0 3 8" 1'- 1 1 5 8" 8'- 1 7 8" 22'-10" 11'-9 12" “522) PITCH “522) PITCH NEW CEDAR SHAKE ROOF TO 0$7&+(;,67,1*“VI NEW SNOW RETENTION BARS TO MATCH EXTG. TYPICAL ROOF CONSTRUCTION: -CEDAR SHAKE SHINGLES TO MATCH EXISTING ROOF -WATERPROOF MEMBRANE -58" CDX PLYWOOD -R-49 MIN BATT INSULATION -VAPOR BARRIER -58" GYP. BD. 1 A200 21 A201 2 A203 1 scale 1/4"=1'-0" ROOF PLAN - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 2 scale 1/4"=1'-0" ROOF PLAN - EXISTING Reviewed for Code Compliance Code: 2012 International Building Code (IBC) GARAGE XXX TO SLAB 102'-0" TYP. @ PERIMETER TO SLAB 102'-6" TO SLAB 102'-0" ELEV. TO LANDING 107'-4 1/2" CRAWL SPACE 5'-0" HEAD HEIGHT T.O. GYPCRETE 110'-6" UP UP TOTAL EXISTING AREA: 756 SQ. FT. 1 A201 2 A200 2 A203 S S S J J , , GFI 220 GFI220 EFTHUL I I I I I I I , S S R R 3 3 6 WATER COP HEATER GARAGE 100 TO SLAB 97'-8" TYP. @ PERIMETER TO SLAB 97'-8" ELEV. TO LANDING 101'- 4" MECH.ROOM 101 MUD 102 RISE - 6 @ 7.36" LAUNDRY 103 STAIR 104 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: 1 100 1 101 1 103 2 100 1 104 RISE - 9 @ 7.4" T.O. SLAB 98'-3 1/2" 3' - 0 " 19'-3 12" 9'-8" 4'- 1 1 78" 312" 4'- 9 " 5'-8 " 3'- 2 12" 3'- 8 12" 10'- 8 38" 3 1 2" 4' - 9 7 8" 312" 3 1 2" 3'-7 14" 312" 5'- 8 38" 8"6" 19'- 1 0 1 8" TILE CON C R E T E TILE WD, 2 A 3 0 0 T.O. SLAB 98'-3 1/2" BOTTOM OF 1ST STAIR 98'-9 5/8" 31 2" 8" 512" 7.07" RISE - 14 STEPS I I I I R R I D D D D D D D J J D- D- D- D- D- GFI220 GFI220 6 I D- RCP/ELECTRICAL KEY: SMOKE DETECTOR LOCATION CARBON MONOXIDE DETECTOR LOCATION; TO BE INSTALLED PER THE STATE OF COLORADO REGULATIONS (HARDWIRED) S CO GENERAL ELECTRICAL NOTES: 1. TYPICAL COLOR OF OUTLETS, SWITCHES, AND COVERS, VFY. 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2012 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH FINAL FURNITURE LAYOUTS. 6. VERIFY MANUF. POWER REQUIREMENTS FOR ALL APPLIANCES. 7. PROVIDE LOCK BOXES FOR FIRE DEPT. AT EACH UNIT 8. DEMOLITION ELECTRICAL DEPICTED IN DRAWING WITH DASHED LINES. NEW ELECTRICAL DEPICTED IN DRAWING WITH SOLID LINES. LIGHTING SYMBOLS C A RECESSED LENSED SHOWER LIGHT: MR 16 4" DOWNLIGHT RECESSED CAN LIGHT: MR 16 B L 4" LENSED DOWNLIGHT D UNDER-CABINET LIGHT F UCH J-BOX / DECORATIVE PENDANT LIGHT J K DECORATIVE WALL-MOUNTED SCONCE LENSED WHERE NOTED; LED WHERE NOTED LEDCOVE LIGHTING L M LED PUCK-LIGHT N CEILING MOUNT K I FLUORESCENT LIGHTING EXTERIOR SCONCER VANITY MIRROR W/ BUILT-IN LIGHTS SPEAKERSP BATHROOM EXHAUST FANEF EXHAUST FAN/LIGHT COMBO GROUND FAULT DUPLEX OUTLET @ +42" U.O.N. U SMOKE DETECTOR DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N. GFI 220 OUTLET220 MOTION SWITCHMS CENTERED IN BASEBD U.O.N. QUAD. OUTLET, MNT. HORIZ. CENTERED IN BASEBD U.O.N. WALL MOUNTED TELEPHONE OUTLET RECESSED FLOOR OUTLET 6 THERMOSTAT TV 2 RG6 COAXIAL LIGHTING CONTROLS KEYPAD LOCATIONKEY LIGHTING CONTROLS CIRCUIT### * DENOTES WIRELESS TABLETOP MODEL E G L RECESSED LENSED SHOWER LIGHT: MR16 4" LENSED DOWNLIGHT CEILING FAN WIRING LUTRON Q (OR SIM.) KEY PAD LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND- 4" DOWNLIGHT NEW RECESSED CAN LIGHT: LED KEY DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N. VFY. W/ TILE LAYOUTSRECESSED CAN LIGHT: LIGHT 6" O 4" ADJUSTABLE RECESSED CAN LIGHT: LED ART LIGHT TRACK LIGHTINGT UPLIGHTU W RECESSED WALL STEP-LIGHT * 12" A.F.F. - LED * * Y*IN FLOOR LIGHT *4" ADJUSTABLE RECESSED CAN LIGHT: LED S SWITCH DS SWITCH DIMMER 3S 3 WAY SWITCH RECESSED LENSED SHOWER LIGHT: 6" LENSED DOWNLIGHT L JS JAMB SWITCH ,J BOXS4" LENSED DOWNLIGHT RECESSED LENSED LIGHT: LED L 2 scale 1/4"=1'-0" GARAGE LEVEL RCP - EXISTING 1 scale 1/4"=1'-0" GARAGE LEVEL RCP - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) JR. MASTER BEDROOM 205 GUEST 202 T.O. STONE 111'-5 5/8" T.O. FINISH FLOOR 106'-10 5/8" UP TO SLAB 97-8" ELEV. BENCH GALLERY 206 G. BATH 200 DN ENTRY PORCH RISE - 8@ 6.9" CLOSET 201 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: JR. BATH 203 1 200 1 202 1 201 2 206 1 205 1 203 1 204 1 206JR. W.C. 204 RISE - 8@ 6.9" 312" 3' - 8 12" 3 1 2" 12'-8 12" 51 2" 2'- 0 1 4" 6'-2 12" 8'- 1 1 8" 2'-1 58 " 9'-4 1 4 " 8'-9 5 8 " 3' - 0 " 3'-1" 3 12" 31 2" 7' - 1 1 1 4" 6'- 7 1 4" 312" 14 ' - 3 " 1'-0" 2'-1 0 78" 3 12" 4' - 8 12" 1'- 1 1 58" 5'- 1 0 34" 3'-0 "3 12" 3'- 0 1 8" 21'- 1 1 7 8" CPT. W D , CPT . W D , CP T . TILE CP T . TIL E 2A 3 0 0 BOTTOM OF 1ST STAIR 98'-9 5/8" CLOSET 207 1 207 4'-0 3 4" 3'- 8 1 2" 3 1 2" 12 ' - 3 5 8"R W W W W W W O O O C C C C C C O E E D- C C C C C J J C EF C C C BL D- D- D- D- D- D- D-C C C C C C C E E J D- EF C C C C C R D- D- D- D- D- D- C C D- D- T V D- D- D- D- TV U U C O C O RCP/ELECTRICAL KEY: SMOKE DETECTOR LOCATION CARBON MONOXIDE DETECTOR LOCATION; TO BE INSTALLED PER THE STATE OF COLORADO REGULATIONS (HARDWIRED) S CO GENERAL ELECTRICAL NOTES: 1. TYPICAL COLOR OF OUTLETS, SWITCHES, AND COVERS, VFY. 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2012 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH FINAL FURNITURE LAYOUTS. 6. VERIFY MANUF. POWER REQUIREMENTS FOR ALL APPLIANCES. 7. PROVIDE LOCK BOXES FOR FIRE DEPT. AT EACH UNIT 8. DEMOLITION ELECTRICAL DEPICTED IN DRAWING WITH DASHED LINES. NEW ELECTRICAL DEPICTED IN DRAWING WITH SOLID LINES. LIGHTING SYMBOLS C A RECESSED LENSED SHOWER LIGHT: MR 16 4" DOWNLIGHT RECESSED CAN LIGHT: MR 16 B L 4" LENSED DOWNLIGHT D UNDER-CABINET LIGHT F UCH J-BOX / DECORATIVE PENDANT LIGHT J K DECORATIVE WALL-MOUNTED SCONCE LENSED WHERE NOTED; LED WHERE NOTED LEDCOVE LIGHTING L M LED PUCK-LIGHT N CEILING MOUNT K I FLUORESCENT LIGHTING EXTERIOR SCONCER VANITY MIRROR W/ BUILT-IN LIGHTS SPEAKERSP BATHROOM EXHAUST FANEF EXHAUST FAN/LIGHT COMBO GROUND FAULT DUPLEX OUTLET @ +42" U.O.N. U SMOKE DETECTOR DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N. GFI 220 OUTLET220 MOTION SWITCHMS CENTERED IN BASEBD U.O.N. QUAD. OUTLET, MNT. HORIZ. CENTERED IN BASEBD U.O.N. WALL MOUNTED TELEPHONE OUTLET RECESSED FLOOR OUTLET 6 THERMOSTAT TV 2 RG6 COAXIAL LIGHTING CONTROLS KEYPAD LOCATIONKEY LIGHTING CONTROLS CIRCUIT### * DENOTES WIRELESS TABLETOP MODEL E G L RECESSED LENSED SHOWER LIGHT: MR16 4" LENSED DOWNLIGHT CEILING FAN WIRING LUTRON Q (OR SIM.) KEY PAD LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND- 4" DOWNLIGHT NEW RECESSED CAN LIGHT: LED KEY DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N. VFY. W/ TILE LAYOUTS RECESSED CAN LIGHT: LIGHT 6" O 4" ADJUSTABLE RECESSED CAN LIGHT: LED ART LIGHT TRACK LIGHTINGT UPLIGHTU W RECESSED WALL STEP-LIGHT * 12" A.F.F. - LED * * Y*IN FLOOR LIGHT *4" ADJUSTABLE RECESSED CAN LIGHT: LED S SWITCH DS SWITCH DIMMER 3S 3 WAY SWITCH RECESSED LENSED SHOWER LIGHT: 6" LENSED DOWNLIGHT L JS JAMB SWITCH ,J BOXS4" LENSED DOWNLIGHT RECESSED LENSED LIGHT: LED L 1 scale 1/4"=1'-0" NEW BEDROOM LEVEL RCP - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) E L E V . MASTER BEDROOM XXX MASTER BATH XXX CLOSET XXX BEDROOM #2 XXX BATH #2 XXX T.O. STONE 121'-0" T.O. GYPCRETE 116'-0" UP TO SLAB 102'-0" DN TOTAL EXISTING AREA: 814 SQ. FT. 1 A200 1 A201 2 A203 4'-9 12" 3'- 8 1 2" D D D D 3 D S 3 D S S 3 D S S S 3D S R FL J DSSSEF DSDS6 TV TV D DD D J J DS VOLUME JS I U S S S S A A A A A A A 3 D S3D S3D A A 3 D D SP SP SP S DA 6 SDSD J J EF SDS D D D FL FL D D MASTER SUITE 303 MASTER BATH 304 GUEST 301 T.O. STONE 121'-0" T.O. GYPCRETE 116'-0" UP ELEV. CLOSET 306 MASTER W.C. 305 NEW AREA: 170 SQ. FT. DN 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: CLOSET #2 302 1 307 G.BATH 300 HALLWAY#3 307 1 301 1 303 1 302 1 304 1 305 1 306 RISE - 8@ 7.25" RISE - 8@ 7.25" SLAB ON GRADE 9'-5" 312"4'-6 1 4" 3 1 2" 13'-6 1 4 " 512" 2' - 1 0 1 4 " 3'-4 3 8" 8'-10 18" 2'- 8 5 8" 4'- 8 18" 4'-8 18" 11 ' - 1 1 8" 6'- 1 34" 23'-6" 4'- 2 " 6'-5 12" 3'- 9 18" 3 1 2" 12 ' - 7 18" 5 1 2" 3 1 2"4'- 2 1 2" 51 2" 6'-9 12" 5 1 2" 13'-8 78 " 3 1 2" 2'-0" 3'-6" 2'-4 1 8 " 1'-2" 5 12 " 9'-0 1 8 " 8'- 1 1 4" 5 12" 3'- 4 14"31 2" 1'- 6 " 5'-8 1 2" 3 1 2 " 5 1 2" 15 ' - 1 3 4" 1'- 6 " 3 1 2" 11'- 5 12" 5 1 2" C P T . WD. CPT. TI L E CPT. TI L E CP T . WD . CP T . TILE 2 A 3 0 0 C EXISTING SWITCH LEGS AND WIRING TO REMAIN. VFY NEW FIXTURES W/ CLIENT. EXISTING SWITCH LEGS AND WIRING TO REMAIN. VFY NEW FIXTURES W/ CLIENT. C C C C C E E D- D- D- D- C C C C D- TV D- D- D- E D- E C C C C C C C C D- D- C D- C C C C C C C D- C C C C C J J J C R D- R C GFI220 D- D- D- SL SL D- D- RCP/ELECTRICAL KEY: SMOKE DETECTOR LOCATION CARBON MONOXIDE DETECTOR LOCATION; TO BE INSTALLED PER THE STATE OF COLORADO REGULATIONS (HARDWIRED) S CO GENERAL ELECTRICAL NOTES: 1. TYPICAL COLOR OF OUTLETS, SWITCHES, AND COVERS, VFY. 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2012 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH FINAL FURNITURE LAYOUTS. 6. VERIFY MANUF. POWER REQUIREMENTS FOR ALL APPLIANCES. 7. PROVIDE LOCK BOXES FOR FIRE DEPT. AT EACH UNIT 8. DEMOLITION ELECTRICAL DEPICTED IN DRAWING WITH DASHED LINES. NEW ELECTRICAL DEPICTED IN DRAWING WITH SOLID LINES. LIGHTING SYMBOLS C A RECESSED LENSED SHOWER LIGHT: MR 16 4" DOWNLIGHT RECESSED CAN LIGHT: MR 16 B L 4" LENSED DOWNLIGHT D UNDER-CABINET LIGHT F UCH J-BOX / DECORATIVE PENDANT LIGHT J K DECORATIVE WALL-MOUNTED SCONCE LENSED WHERE NOTED; LED WHERE NOTED LEDCOVE LIGHTING L M LED PUCK-LIGHT N CEILING MOUNT K I FLUORESCENT LIGHTING EXTERIOR SCONCER VANITY MIRROR W/ BUILT-IN LIGHTS SPEAKERSP BATHROOM EXHAUST FANEF EXHAUST FAN/LIGHT COMBO GROUND FAULT DUPLEX OUTLET @ +42" U.O.N. U SMOKE DETECTOR DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N. GFI 220 OUTLET220 MOTION SWITCHMS CENTERED IN BASEBD U.O.N. QUAD. OUTLET, MNT. HORIZ. CENTERED IN BASEBD U.O.N. WALL MOUNTED TELEPHONE OUTLET RECESSED FLOOR OUTLET 6 THERMOSTAT TV 2 RG6 COAXIAL LIGHTING CONTROLS KEYPAD LOCATIONKEY LIGHTING CONTROLS CIRCUIT### * DENOTES WIRELESS TABLETOP MODEL E G L RECESSED LENSED SHOWER LIGHT: MR16 4" LENSED DOWNLIGHT CEILING FAN WIRING LUTRON Q (OR SIM.) KEY PAD LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND- 4" DOWNLIGHT NEW RECESSED CAN LIGHT: LED KEY DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N. VFY. W/ TILE LAYOUTS RECESSED CAN LIGHT: LIGHT 6" O 4" ADJUSTABLE RECESSED CAN LIGHT: LED ART LIGHT TRACK LIGHTINGT UPLIGHTU W RECESSED WALL STEP-LIGHT * 12" A.F.F. - LED * * Y*IN FLOOR LIGHT *4" ADJUSTABLE RECESSED CAN LIGHT: LED S SWITCH DS SWITCH DIMMER 3S 3 WAY SWITCH RECESSED LENSED SHOWER LIGHT: 6" LENSED DOWNLIGHT L JS JAMB SWITCH ,J BOXS4" LENSED DOWNLIGHT RECESSED LENSED LIGHT: LED L 2 scale 1/4"=1'-0" MASTER LEVEL RCP - EXISTING 1 scale 1/4"=1'-0" MASTER LEVEL RCP - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) ELEV. LIVING XXX KITCHEN XXX POWDER XXX 131'-0" T.O. STONE TO STONE 125'-11" T.O. GYPCRETE 126'-0" UP D/W TO STONE 125'-11" OPEN TO ENTRY BELOW TOTAL EXISTING AREA: 821 SQ. FT. 1 A200 1 A201 2 A203 FD FD J EF DS S D D D U D S S D S D D D D D D D SP D GFI220 GFI220 SDVOLUME SS U C H U C H 6J J J DSSSS K S D VOLUME R R GL SDF/P TV S S R R E L E V . LIVING 403 KITCHEN 401 131'-0" T.O. STONE TO STONE 125'-11" T.O. GYPCRETE 126'-0" UP TO STONE 125'-11" DN DECK DECK POWDER 400 WIRED FOR HOT TUB OUTDOOR LIVING 406 DOG RUN 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: B B Q DINING 402 1 302 HALLWAY#4 405 RISE - 8@ 7.7" 8" 6'-5 12" 4"5 1 2" 4'- 0 " 51 2" 134" 4'- 1 1 2" 5'- 2 12" 5'-8 3 4" 14 ' - 1 " 5'-2 3 8" 7'-0" 31 2" 5'-8 1 4" 1" 4'-8 58" 1" 5'-3" 18'-4" 5 1 2 " W D . W D . 2 A 3 0 0 RANGE DRY BAR XXX 16'- 7 3 4" W5 x 1 6 8 " 3'-7 58" 11 1 2" 13'-4" 5'-5 1 2" W5 x 1 6 R R R R K K C C C CC CC C C C C EXISTING SWITCH LEGS AND WIRING TO REMAIN. VFY NEW FIXTURES W/ CLIENT. CC C K J J J RR RR D- D- D- D- UC UC UC EXISTING SWITCH LEGS AND WIRING TO REMAIN. VFY NEW FIXTURES W/ CLIENT. J J D- J J D- D- D- 6 D- D- UC UC UC C D- GFI 220 TV D- RCP/ELECTRICAL KEY: SMOKE DETECTOR LOCATION CARBON MONOXIDE DETECTOR LOCATION; TO BE INSTALLED PER THE STATE OF COLORADO REGULATIONS (HARDWIRED) S CO GENERAL ELECTRICAL NOTES: 1. TYPICAL COLOR OF OUTLETS, SWITCHES, AND COVERS, VFY. 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2012 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH FINAL FURNITURE LAYOUTS. 6. VERIFY MANUF. POWER REQUIREMENTS FOR ALL APPLIANCES. 7. PROVIDE LOCK BOXES FOR FIRE DEPT. AT EACH UNIT 8. DEMOLITION ELECTRICAL DEPICTED IN DRAWING WITH DASHED LINES. NEW ELECTRICAL DEPICTED IN DRAWING WITH SOLID LINES. LIGHTING SYMBOLS C A RECESSED LENSED SHOWER LIGHT: MR 16 4" DOWNLIGHT RECESSED CAN LIGHT: MR 16 B L 4" LENSED DOWNLIGHT D UNDER-CABINET LIGHT F UCH J-BOX / DECORATIVE PENDANT LIGHT J K DECORATIVE WALL-MOUNTED SCONCE LENSED WHERE NOTED; LED WHERE NOTED LEDCOVE LIGHTING L M LED PUCK-LIGHT N CEILING MOUNT K I FLUORESCENT LIGHTING EXTERIOR SCONCER VANITY MIRROR W/ BUILT-IN LIGHTS SPEAKERSP BATHROOM EXHAUST FANEF EXHAUST FAN/LIGHT COMBO GROUND FAULT DUPLEX OUTLET @ +42" U.O.N. U SMOKE DETECTOR DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N. GFI 220 OUTLET220 MOTION SWITCHMS CENTERED IN BASEBD U.O.N. QUAD. OUTLET, MNT. HORIZ. CENTERED IN BASEBD U.O.N. WALL MOUNTED TELEPHONE OUTLET RECESSED FLOOR OUTLET 6 THERMOSTAT TV 2 RG6 COAXIAL LIGHTING CONTROLS KEYPAD LOCATIONKEY LIGHTING CONTROLS CIRCUIT### * DENOTES WIRELESS TABLETOP MODEL E G L RECESSED LENSED SHOWER LIGHT: MR16 4" LENSED DOWNLIGHT CEILING FAN WIRING LUTRON Q (OR SIM.) KEY PAD LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND- 4" DOWNLIGHT NEW RECESSED CAN LIGHT: LED KEY DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N. VFY. W/ TILE LAYOUTS RECESSED CAN LIGHT: LIGHT 6" O 4" ADJUSTABLE RECESSED CAN LIGHT: LED ART LIGHT TRACK LIGHTINGT UPLIGHTU W RECESSED WALL STEP-LIGHT * 12" A.F.F. - LED * * Y*IN FLOOR LIGHT *4" ADJUSTABLE RECESSED CAN LIGHT: LED S SWITCH DS SWITCH DIMMER 3S 3 WAY SWITCH RECESSED LENSED SHOWER LIGHT: 6" LENSED DOWNLIGHT L JS JAMB SWITCH ,J BOXS4" LENSED DOWNLIGHT RECESSED LENSED LIGHT: LED L 2 scale 1/4"=1'-0" LIVING LEVEL RCP - EXISTING 1 scale 1/4"=1'-0" LIVING LEVEL RCP - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) DN LOFT XXX T.O. GYPCRETE 136'-0" T.O. STONE 135'-11" OPEN TO BELOW TOTAL EXISTING AREA: 377 SQ. FT. CL O S E T 1 A200 1 A201 2 A203 U U DSVOLUME SP S R DS J J D D SS 6 U DS S S J J EF D FL TV SP JS DN LOFT 500 T.O. GYPCRETE 136'-0" T.O. STONE 135'-11" OPEN TO BELOW, <16'H 1 A200 1 A202 1 A203 EXISTING WALL NEW WALL DEMOLISH WALL TYPE KEY: 1 5011 500 LOFT BATH 501 3 12" 2'- 7 34" 31 2"5 1 2" 31 2 " 1' - 6 " CL O S E T 6'-6 " 8'- 6 34" 6'- 7 1 2" 7'- 7 5 8" 6'-5" 3'-4" 3' - 4 " 3'-4" 6'-3 1 2" TILE WD. W D . W D . 2 A 3 0 0 EXISTING SWITCH LEGS AND WIRING TO REMAIN. VFY NEW FIXTURES W/ CLIENT.FL DS S S J EF J S C RCP/ELECTRICAL KEY: SMOKE DETECTOR LOCATION CARBON MONOXIDE DETECTOR LOCATION; TO BE INSTALLED PER THE STATE OF COLORADO REGULATIONS (HARDWIRED) S CO GENERAL ELECTRICAL NOTES: 1. TYPICAL COLOR OF OUTLETS, SWITCHES, AND COVERS, VFY. 2. POWER AND LIGHTING DISTRIBUTION TO FOLLOW REQUIREMENTS PER 2012 IRC 3. ELECTRICAL WALK-THRU IS REQUIRED WITH ARCHITECT AT ROUGH-IN 4. VERIFY ALL FLOOR OUTLET LOCATIONS WITH FINAL FURNITURE LAYOUTS 5. VERIFY HEIGHTS OF RECEPTACLES FOR TVs WITH FINAL FURNITURE LAYOUTS. 6. VERIFY MANUF. POWER REQUIREMENTS FOR ALL APPLIANCES. 7. PROVIDE LOCK BOXES FOR FIRE DEPT. AT EACH UNIT 8. DEMOLITION ELECTRICAL DEPICTED IN DRAWING WITH DASHED LINES. NEW ELECTRICAL DEPICTED IN DRAWING WITH SOLID LINES. LIGHTING SYMBOLS C A RECESSED LENSED SHOWER LIGHT: MR 16 4" DOWNLIGHT RECESSED CAN LIGHT: MR 16 B L 4" LENSED DOWNLIGHT D UNDER-CABINET LIGHT F UCH J-BOX / DECORATIVE PENDANT LIGHT J K DECORATIVE WALL-MOUNTED SCONCE LENSED WHERE NOTED; LED WHERE NOTED LEDCOVE LIGHTING L M LED PUCK-LIGHT N CEILING MOUNT K I FLUORESCENT LIGHTING EXTERIOR SCONCER VANITY MIRROR W/ BUILT-IN LIGHTS SPEAKERSP BATHROOM EXHAUST FANEF EXHAUST FAN/LIGHT COMBO GROUND FAULT DUPLEX OUTLET @ +42" U.O.N. U SMOKE DETECTOR DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N. GFI 220 OUTLET220 MOTION SWITCHMS CENTERED IN BASEBD U.O.N. QUAD. OUTLET, MNT. HORIZ. CENTERED IN BASEBD U.O.N. WALL MOUNTED TELEPHONE OUTLET RECESSED FLOOR OUTLET 6 THERMOSTAT TV 2 RG6 COAXIAL LIGHTING CONTROLS KEYPAD LOCATIONKEY LIGHTING CONTROLS CIRCUIT### * DENOTES WIRELESS TABLETOP MODEL E G L RECESSED LENSED SHOWER LIGHT: MR16 4" LENSED DOWNLIGHT CEILING FAN WIRING LUTRON Q (OR SIM.) KEY PAD LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND- 4" DOWNLIGHT NEW RECESSED CAN LIGHT: LED KEY DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N. VFY. W/ TILE LAYOUTSRECESSED CAN LIGHT: LIGHT 6" O 4" ADJUSTABLE RECESSED CAN LIGHT: LED ART LIGHT TRACK LIGHTINGT UPLIGHTU W RECESSED WALL STEP-LIGHT * 12" A.F.F. - LED * * Y*IN FLOOR LIGHT *4" ADJUSTABLE RECESSED CAN LIGHT: LED S SWITCH DS SWITCH DIMMER 3S 3 WAY SWITCH RECESSED LENSED SHOWER LIGHT: 6" LENSED DOWNLIGHT L JS JAMB SWITCH ,J BOXS4" LENSED DOWNLIGHT RECESSED LENSED LIGHT: LED L 2 scale 1/4"=1'-0" LOFT LEVEL RCP - EXISTING 1 scale 1/4"=1'-0" LOFT LEVEL RCP - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) TO SLAB 102'-0" MASTER 116'-0" LIVING 126'-0" SPRING POINT 134'-8" TO STONE CAP 147'-8" JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE TO MATCH EXISTING NEW STEEL FRENCH BALCONY TO MATCH EXISTING M01 STONE TO MATCH EXISTING M02 VERTICAL SIDING M03 WINDOWS AND DOORS M05 M04 ROOF M06 TO MATCH EXISTING GUTTER SYSTEM M09 GUTTER M10 RAILING FINISHES KEY FASCIA M11 TO MATCH EXISTING RAILING M12 GARAGE DOOR M13 TO MATCH EXISTING M08 M07 SNOW FENCE L82.4 SNOW FENCE BY ROCKY MOUNTAIN SNOW GUARDS INC. M14 TO MATCH EXISTING M05 M02 M01 M01 M03 M08 MASTER 116'-0" LIVING 126'-0" SPRING POINT 134'-8" TO SLAB 97'-8" EXISTING STAIRWELL WALL NEW MASTER FRENCH BALCONY NEW MASTER SHOWER WINDOW NEW DINING SLIDER EXISTING BAY WINDOW EXISTING BAY WINDOW NEW DINING WINDOW NEW ENTRY WINDOW NEW JR. MASTER DOOR NEW JR. MASTER WINDOW TOP OF DORMER 143'-11 3/8" M05 M02 M01 M03 M08 M08 NEW MASTER WINDOW NEW MASTER DOOR NEW MASTER WINDOW M08 NEW JR. MASTER DECK EXISTING LIVING BALCONY NEW LIVING ADDITION WALL 7.07" rise - 14 steps 5' - 1 1 " 6' - 1 1 15 16 " EXISTING LANDING 111'-7 7/16" NEW BEDROOM 106'-10 5/8" 11 5 8" NEW ENTRY LANDING 104'-8 5/8" (TO BE DEMOLISHED) BOTTOM OF 1ST ENTRY STAIR 98'-9 5/8" EXISTING RETAINING WALL TO REMAIN LOFT 136'-0" 2' - 0 " NEW DINING WINDOW 5' - 4 3 16 " 12 “ NEW RAILING TO MATCH EXTG., NOT TO ALLOW 7+(3$66*(2)$‘63+(5(7<3 NEW STEEL TRELLIS ELEVATIONS A200 2 1/4" = 1'-0" WEST ELEVATION - EXISTING 1 1/4" = 1'-0" WEST ELEVATION - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) TO SLAB 99'-6" BEDROOM 114'-0" LIVING 124'-0" LOFT 134'-0" TO STONE CAP 147'-8" MASTER 116'-0" LIVING 126'-0" SPRING POINT 134'-8" TO STONE CAP 147'-8" TO SLAB 102'-0" JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE TO MATCH EXISTING NEW STEEL FRENCH BALCONY TO MATCH EXISTING M01 STONE TO MATCH EXISTING M02 VERTICAL SIDING M03 WINDOWS AND DOORS M05 M04 ROOF M06 TO MATCH EXISTING GUTTER SYSTEM M09 GUTTER M10 RAILING FINISHES KEY FASCIA M11 TO MATCH EXISTING RAILING M12 GARAGE DOOR M13 TO MATCH EXISTING M08 M07 SNOW FENCE TO MATCH EXISTING M14 TO MATCH EXISTING M01 M01 M01 M01 M02 M02 M01 M03 M03 M03 M04 M04 M05 M05 M08 M08 M10 M10 4' - 5 716 " EXISTING LANDING 111'-7 7/16" ELEVATIONS A201 1 1/4" = 1'-0" WEST ELEVATION - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) TO SLAB 99'-6" BEDROOM 114'-0" LIVING 124'-0" LOFT 134'-0" TO STONE CAP 147'-8" MASTER 116'-0" LIVING 126'-0" SPRING POINT 134'-8" TO STONE CAP 147'-8" TO SLAB 97-8" JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE TO MATCH EXISTING NEW STEEL FRENCH BALCONY TO MATCH EXISTING M01 STONE TO MATCH EXISTING M02 VERTICAL SIDING M03 WINDOWS AND DOORS M05 M04 ROOF M06 TO MATCH EXISTING GUTTER SYSTEM M09 GUTTER M10 RAILING FINISHES KEY FASCIA M11 TO MATCH EXISTING RAILING M12 GARAGE DOOR M13 TO MATCH EXISTING M08 M07 SNOW FENCE TO MATCH EXISTING M14 TO MATCH EXISTING M01 M01 M01 M01 M02 M02 M01 M03 M03 M04 M04 M05 M05 M08 M08 M10 M10 NEW JR. MASTER WINDOW NEW JR. MASTER DOORNEW JR. MASTER WINDOW NEW GUEST WINDOW NEW MASTER WINDOW NEW MASTER DOOR NEW MASTER SHOWER WINDOWEXISTINGBAY WINDOW EXISTINGBAY WINDOW NEWGUEST WINDOW NEW DINING WINDOW F.P. W/ GLASS NEW ENTRY CORRIDOR EXISTING BAY WINDOW NEW JR. MASTER WINDOW NEW JR. MASTER WINDOW NEW MASTER WINDOW EXISTING LOFT WINDOW EXISTING BAY WINDOW NEW KITCHEN WINDOW EXISTING LOFT WINDOW NEW WINDOW NEW LIVING DOOR NEW WINDOW NEW WINDOW NEW BEDROOM 106'-10 5/8" 9 99 ELEVATION A202 1 1/4" = 1'-0" WEST ELEVATION - PROPOSED PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) 147'-8" MASTER 116'-0" LIVING 126'-0" SPRING POINT 134'-8" TO STONE CAP TO SLAB 102'-0" LOFT 136'-0" MASTER TO GYPCRETE 116'-0" LIVING TO GYPCRETE 126'-0" SPRING POINT 134'-8" TO SLAB 97'-8" NEW LIFT AND SLIDE POCKET DOOR NEW BEDROOM 106'-10 5/8" NEW ENTRY DOOR EXISTINGWINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN EXISTING WINDOW TO REMAIN NEW ADDITION WALL NEW MASTER ADDITION NEW BEDROOM LEVEL ADDITION NEW GARAGE ADDITION M02 OUTDOOR PATIO M05 M03 JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE M08 TO MATCH EXISTING TO MATCH EXISTING NEW IRON RAILING M01 TO MATCH EXISTINGSTONE VERTICAL SIDING M03 M02 M05 WINDOWS AND DOORSM04 ROOF M06 M09 TO MATCH EXISTING GUTTER SYSTEM M10 GUTTER FINISHES KEY RAILING M11 M12 FASCIA M07 GARAGE DOOR TO MATCH EXISTING RAILING SNOW FENCE M08 M13 TO MATCH EXISTING TO MATCH EXISTING M14 M04 TO MATCH EXISTING M08 EXISTING STONE WALL NEW JR. BED DECK NEW MASTER FRENCH BALCONY EXISTING DINING/LIVING BALCONY M08 NEW ENTRY IRON HANDRAIL 7' - 6 " 8' - 1 15 16 " 28 ' - 1 " 5/8" DRYWALL CEILING FINISH 34" PLYWOOD 912" LVL JOISTS 13/16" WARMBOARD-R 8' - 3 3 8" 4' - 3 15 16 " 1" FINISH FLOOR 1" DRYWALL CEILING FINISH 34" PLYWOOD 16" BVC JOISTS 2" GYPCRETE 1" FINISH FLOOR 3' - 4 " EXISTING GARAGE FLOOR ELEVATION 6" EXISTING MECHANICAL ROOM ELEVATION PROPOSED MECHANICAL ROOM HEIGHT PROPOSED HEIGHT OF GARAGE LOWERING TO SLAB 102'-6" 212" FLAGSTONE 34" PLYWOOD 712" LVL 1' - 8 3 8" NEW 7'6" TALL GARAGE DOOR 9' - 2 58" NEW GARAGE LEVEL ADDITION 1' - 4 5 8" 1' - 0 11 16 " EXISTING FLOOR ASSEMBLY TO REMAIN EXISTING FLOOR ASSEMBLY TO REMAIN NEW FLOOR ASSEMBLY NEW SLAB LOFT 136'-0" ELEVATION A203 1 1/4" = 1'-0" SOUTHWEST ELEVATION - PROPOSED21/4" = 1'-0" SOUTHWEST ELEVATION - EXISTING PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) FINISH ROOFING COPPER FLASHING 6" HALF-ROUND COPPER GUTTER T&G SOFFIT TO MATCH EXTG. WOOD FASCIA BLOWN-IN INSUL. R-49 (MIN) ROOF UNDERLAYMENT / WATERPR. MEMBR. 7 12 T.O.PLATE 2x6 EXT. WALL W/MIN. R-21 BLOWN-IN OR BATT INSUL 58" GYPSUM WALL BOARD VFY O/HANG W/ EXTG CLEAN 3/4" FREE DRAINING GRAVEL GRAVEL THIS AREA REGARDLESS OF WHETHER DRAIN IS LOCATED AT THIS LOCATION MIN. 1" X 1" BUILT-UP CANT OF FLUID-APPLIED WATERPROOFING AT ALL INSIDE CORNERS FILTER FABRIC CONC. SLAB RE: STRUCT. EXPANSION MATERIAL CONC FTG RE: STRUCT. DRAIN & DRY BD ‘5,*,'3(5)25$7('3,3(6/23('# 14" PER FOOT TO A DAYLIGHT OR A SUMP LOCATION CONC FDN WALL RE: STRUCT. SEE STRUCT DWGS T.O. FTG 2X FURRED WALL W/ BIBBS INSUL., TYP. 58" DRYWALL, TYP. HOT-APPLIED, MONOLITHIC WATERPROOFING MEMBRANE-- EXTEND WATERPROOFING 36" ABOVE GRADE AND TO BOTTOM OF FOOTING WATER STOP, TYP. COPPER FLASHING; SEAL LAPS 12" EXT. PLYWD. SHEATHING 6" STONE VENEER BUILDING PAPER DRAIN & DRY BOARD SEALANT LINE OF GRADE METAL FLASHING W/ 3" VERT. LEG UP WALL FACE LAPPED INTO WATERPROOFING MEMBRANE. PROVIDE HEMMED OUTER EDGE AND LAP & SEAL JOINTS UNCURED NEOPRENE FLASHING--EXTEND 4" ABOVE AND 4" BELOW VENEER LEDGER 12 " ON T O P L Y W D . 12 " L A P 3" SHEET BITUTHANE 2' DRAIN AND DRY BOARD HOT-APPLIED MONOLITHIC WATERPROOFING MEMBRANE -- EXTEND WATERPROOFING 36" ABOVE GRADE AND TO BOTTOM OF FOOTING SHEET BITUTHANE; EXTEND MEMBRANE 12" MIN. ONTO PRIMED SHEATHING LIQUID FILLET OF LM3000 BY GRACE HOT-APPLIED MONOLITHIC WATERPROOFING MEMBRANE -- EXTEND WATERPROOFING 36" ABOVE GRADE AND TO BOTTOM OF FOOTING HOT-APPLIED MONOLITHIC WATERPROOFING MEMBRANE -- EXTEND WATERPROOFING 12" ABOVE LEDGER; LAP 8" OVER BITUTHANE CONCRETE FOUNDATION WALL LIGHTWEIGHT CONC. W/ RADIANT HEAT FINISH FLOOR 10MIL. VAPOR BARRIER O/ R-10 MIN. RIGID FOAM INSULATION 4" FREE DRAINING GRAVEL, NO FINES VAPOR BARRIER (WARM SIDE), TYP. BUILDING PAPER WOOD SIDING TO MATCH EXTG. BLDG. PAPER 12" EXTERIOR PLYWOOD 1-18" PLYWD. SUBFLOOR SANDSTONE PAVERS MORTAR BED w/ SNOW-MELT TUBING DRAINAGE MAT STONE VENEER BUTYL TAPE LAP SEALANT COPPER SCUPPER (FULLY SOLDERED) SEALANT COPPER SCUPPER SLEEVE 6125 MEMBRANE W/ HYDROFLEX 30 EXTEND AH6125 INTO SCUPPER OPENING UNDER HORIZONTAL PORTION OF SCUPPER AND UP BOTH SIDES OF SCUPPER OPENING, UNDER METAL SCUPPER. FELT PAPER; LAP 8" OVER HOT-APPLIED W.P. BITUTHENE LAPPED OVER WPM 6125 AND BLDG. PAPER CONTINUOUS 1" FILLET BEAD OF SEALANT AT TRANSITION FROM HORIZ. TO VERT., TYP. SLOPE TO DRAIN 18" ASPHALTIC PROTECTION BD HEAT TRACE ALL SCUPPERS “ 12" COPPER FLASHING “ 12" “ 1 2" “   12" 3" 3" 3' - 0 " 2x RS CEDAR FASCIA STONE DECKING 2x RS CEDAR TOP AND BOTTOM RAILS 2x RS CEDAR PICKETTS ‘ 6x6 RS CEDAR NEWELLS “ 1 2" FRONT SIDE 1 1-1/2"=1'-0" TYP. WALL SECTION 2 1"=1'-0" OVERFLOW SCUPPER DETAIL PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 3/4"=1'-0" EXTERIOR RAILING DETAIL3 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) GLAZING REMARKSFRAME MAT'L.WINDOW TYPE TYPE / MANUF. MASTER LEVEL FRAME MAT'L.GLAZING REMARKSWINDOW TYPE NEW BEDROOM LEVEL TYPE / MANUF. W1 W2 W3 ALUMINUM ALUMINUM INTERIOR FRAME MAT'L. INTERIOR FRAME MAT'L. WINDOW R.O. WINDOW R.O.WINDOW SIZE WIDTH X HT. WINDOW SIZE WIDTH X HT. VFY. 5'-0" x 4'-7 3/4" DBL LOW-E DBL LOW-E DBL LOW-E WOODJELD-WEN JELD-WEN 2'-8" x 4'-5 5/8" EXTERIOR FRAME MAT'L. GLAZING REMARKSWINDOW TYPE W17 WINDOW SCHEDULE - WINDOW SYSTEMS TYPE / MANUF.INTERIOR FRAME MAT'L. ALUMINUM POCKET LIFT AND SLIDE WINDOW R.O.SYSTEM SIZE WIDTH X HT. VFY.13'-4" x 9'-0"DBL LOW-E; TEMPEREDWOODNANA JELD-WEN ALUMINUM T.O. GYPCRETE NEW BEDROOM CASEMENT WINDOW WOOD WOOD QUANTITY QUANTITY QUANTITY 2 1 2 2 W8 W9 ALUMINUM 4'-6 3/4" x VFY." 2'-5 1/4" x 8'-0" DBL LOW-E DBL LOW-EJELD-WEN JELD-WEN ALUMINUM WOOD FRENCH CASEMENT - MATCH HEIGHT W EXISTING MASTER BAY WINDOW HEIGHTS WOOD FIXED 1 2 W10 W12 ALUMINUM DBL LOW-EJELD-WEN OUTSWING FRENCH DOOR 1WOOD6'-0" x 8'-0" R. O . R.O. T.O. GYPCRETE MASTER FRENCH DOOR 5'-0" x 5'-018"DBL LOW-E; TEMPEREDALUMINUMJELD-WEN WOOD 1 U-VALUE .32 .32 .32 .32 .32 .32 .32 .32 GLAZING REMARKSFRAME MAT'L.WINDOW TYPE TYPE / MANUF. LIVING LEVEL INTERIOR FRAME MAT'L. WINDOW R.O.WINDOW SIZE WIDTH X HT. QUANTITY W13 W14 ALUMINUM VFY.3'-6 1/8" x 2'-0 7/8" 5'-6 5/8" x 3'-0" DBL LOW-E DBL LOW-EJELD-WEN JELD-WEN ALUMINUM WOOD CLERESTORY WINDOW - FIXED WOOD FIXED 1 2 W15 W16 W21 ALUMINUM DBL LOW-EJELD-WEN 1WOOD14'-7" x 7'-10" 6'-9 12" x 7'-10"DBL LOW-E; TEMPEREDALUMINUMJELD-WEN WOOD ALUMINUMJELD-WEN WOOD 1 15'-138" x 2'-10"DBL LOW-E FIXED .32 .32 .32 .32 .32 GLAZING REMARKSFRAME MAT'L.WINDOW TYPE TYPE / MANUF. LOFT LEVEL INTERIOR FRAME MAT'L. WINDOW R.O.WINDOW SIZE WIDTH X HT. QUANTITY W19 W20 ALUMINUM 8'-0" x 7'-358"DBL LOW-E DBL LOW-EJELD-WEN JELD-WEN ALUMINUM WOOD WOOD 1 1 W18 ALUMINUM DBL LOW-EJELD-WEN 4WOOD3'-4" x 3'-0" .32 .32 .32 NEW GUEST WINDOW NEW GUEST WINDOW 2'-8" 4' - 5 58" 3'- 0 " VFY. VFY. NEW JR. MASTER WINDOW 3'- 0 " 4' - 5 58" 2'-414" R. O . R.O. 2'- 1 0 " 4'- 7 34" 5'-0" R. O . R.O. 2'-4 1/4 " x 4'-5 5/8" W6 ALUMINUM 6'-2 1/8" x 7'-5 3/4"DBL LOW-EJELD-WEN WOOD 1.32VFY. 6'-218" 7' - 5 34" R. O . R.O. FRENCH SLIDER 1'- 6 58" 5'- 6 34" 4'-1034" R.O. R. O . VFY. NEW MASTER WINDOW FRENCH SLIDER NEW GUEST WINDOW NEW MASTER DOOR 2'-514" 8'- 0 " R. O . R.O. 6'-0" 8'- 0 " R. O . R.O. VFY. VFY. 2' - 1 1 78" 5'- 0 18" 5'-0" R.O. R. O . FRENCH CASEMENT FRENCH CASEMENT T.O. GYPCRETE LIVING FIXED FRENCH CASEMENT VFY. NEW KITCHENWINDOW 6'- 3 78" 2' - 0 78" 3'-618" R.O. R. O . NEW DINING SLIDER 7'- 1 0 " 4'-658" R.O. R. O . VFY. VFY. NEW DINING WINDOW 1'- 0 " 7'- 0 " 2'-4" R.O. R. O . NEW LIVING DOOR 6'-912" 7'- 1 0 " R. O . R.O. VFY. FIXED 4'- 2 58" 2'- 1 0 " 5'-138" R.O. R. O . VFY. T.O. GYPCRETE LOFT FIXED 1'- 6 34" 612" 7'- 3 58" 8'-0" R.O. R. O . 1'- 6 34" 612" 7'- 3 58" 8'-0" R.O. R. O . TRAPEZOID TRAPEZOIDVFY. VFY.8'-0" x 7'-358" 1'- 3 " 1'- 9 " 3'-4" 3'- 0 " VFY.MULTI-UNIT ASSEMBLY NEW LIFT AND SLIDE POCKET DOOR FIXED 9'- 0 " 13'-4" R.O. R. O . 1 1/4"=1'-0" WINDOW ELEVATIONS 3 NS WINDOW SCHEDULE PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) DOOR NO. INTERIOR DOOR SCHEDULE -- GARAGE LEVEL ROOM NO. THICK- NESS MAT'LR.O.SIZETYPE DOORROOM NAME HANDING REMARKS MAT'L PANELS 2100 2'-8" x 7'-0"D2 HINGE TYPE* HARDWARE LEVER TYPE* LOCK TYPE DOOR NO. ROOM NO. THICK- NESS MAT'LR.O.SIZETYPE DOORROOM NAME HANDING REMARKS MAT'L PANELS HINGE TYPE* HARDWARE LEVER TYPE* LOCK TYPE INTERIOR DOOR SCHEDULE -- NEW BEDROOM LEVEL LH 1101MECH. ROOM 2'-6" x 4'-2"D1 VFY.WOOD LH PASSAGE LADDER ACCES NEEDED FOR DOOR. 1103LAUNDRY D3 (2)2'-6" x 7'-0"DBL 1201G. CLOSET D5 RH 1 RH 1 204 JR. W.C. D5 LOCK-SET 1206GALLERY LH 17'-0 34" x 7'-6" RH LOCK TYPE DOOR NO. ROOM NO. THICK- NESS MAT'LR.O.SIZETYPE DOORROOM NAME HANDING REMARKS MAT'L PANELS HINGE TYPE* HARDWARE LEVER TYPE* INTERIOR DOOR SCHEDULE -- SHOWER DOORS 1 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" 1-3/4" SHOWER203A 1 N/ATEMP. GL.2'-0" x 7'-0"N/AN/A PIVOT EURO STYLE GLASS STEAM SHOWER DOOR; MA. HARDWARE TO BATH FIXTURESN/A L1 L2 L3H3 L2 H1 H2 H2 PASSAGE DOOR NO. EXTERIOR DOOR SCHEDULE ROOM NO. TH I C K - NE S S MAT'L: INTERIOR / EXTERIORR.O.SIZETYPE DOORROOM NAME REMARKS 100 GARAGE DOOR 1 XD1 HANDING TRACK HINGE OR TRACK & ASSOCIATED ACCESSORIES TYPE HARDWARE HANDLE / LEVER TYPE LOCK TYPE KEY PADWOOD PANELS 3" STILE @ RAIL OTHER STOP STAY ROLLER & GUIDE STRIP INTERIOR EXTERIOR PRIMARY N/A N/A N/A WOOD PASSAGEL3H3WOOD 202 G. BEDROOM D4 WOOD L3H3 LOCK-SET 200 G. BATH 2'-0" x 7'-0"VFY.LH1-3/4"WOOD LOCK-SETL3H3 LHWOOD L3H3 RHWOOD L3H3 VFY. WOOD WOOD L3H3 1 D4 SPEC. TO BE VARIFIED ELEVATOR VFY.WOOD PASSAGE VFY.PASSAGE 1104STAIR D4 RH1-3/4"L2H2WOOD PASSAGE2'-6" x 7'-0"VFY. 3'-6" x 7'-0"206 ENTRY DOOR 1 XD2 LHWOOD2"VFY.DEAD-BOLT CUSTOM DESIGN TBD 1 D5 2'-0" x 7'-0"VFY. VFY. 203 JR. BATH 2'-6" x 7'-0" 2'-0" x 7'-0"VFY. D5 2'-0" x 7'-0"VFY.LOCK-SET 205 JR. MASTER BED VFY.2'-6" x 7'-0"LOCK-SET 2'-8" x 7'-0"D2 VFY. DOOR NO. INTERIOR DOOR SCHEDULE -- MASTER LEVEL ROOM NO. THICK- NESS MAT'LR.O.SIZETYPE DOORROOM NAME HANDING REMARKS MAT'L PANELS 2302 2'-6" x 7'-0"D4 HINGE TYPE* HARDWARE LEVER TYPE* LOCK TYPE LH 1301G. BEDROOM 4'-0" x 7'-0"D6 VFY.WOOD BARN LOCK-SET 1303MASTER BEDROOM D7 2'-912" x 7'-0"RH 1-3/4" 1-3/4" 1-3/4"L3 L3 L3 H4 H3 H3WOOD CLOSET #2 VFY.WOOD PASSAGE VFY. 1304MASTER BATH D4 PKT1-3/4"L2H5WOOD PASSAGE3'-312" x 7'-0"VFY. LOCK-SET 1305MASTER W.C.D4 LH1-3/4"L3H3WOODVFY. 1306CLOSET D4 PKT1-3/4"L3H5WOOD PASSAGEVFY. 1307HALLWAY #3 LH1-3/4"L3H3WOOD PASSAGEVFY. 2'-6" x 7'-0"LOCK-SET 2'-6" x 7'-0" 2'-8" x 7'-0"D2 DOOR NO. INTERIOR DOOR SCHEDULE -- LIVING LEVEL ROOM NO. THICK- NESS MAT'LR.O.SIZETYPE DOORROOM NAME HANDING REMARKS MAT'L PANELS HINGE TYPE* HARDWARE LEVER TYPE* LOCK TYPE 1301HALLWAY #4 VFY.WOOD LH1-3/4"L3H3 DOOR NO. INTERIOR DOOR SCHEDULE -- LOFT LEVEL ROOM NO. THICK- NESS MAT'LR.O.SIZETYPE DOORROOM NAME HANDING REMARKS MAT'L PANELS HINGE TYPE* HARDWARE LEVER TYPE* LOCK TYPE 1501LOFT BATH 2'-0" x 7'-0"D5 VFY.WOOD RH LOCK-SET1-3/4"L3H3 2'-8" x 7'-0"D2 PASSAGE 1500LOFT 2'-0" x 7'-0"D5 VFY.WOOD LH PASSAGE1-3/4"L3H3 1 1/4"=1'-0" DOOR ELEVATIONS2NS DOOR SCHEDULE PROJECT: 71 0 W E S T L I O N S H E A D C I R C L E - U N I T A V A I L . , C O L O R A D O 8 1 6 5 7 9 7 0 . 4 7 7 . 2 9 9 0 CR O S S R E S I D E N C E 12 6 F O R E S T R D . VA I L , C O DRAWN BY: DATE: REVISIONS: CROSS - 12.06.13 Reviewed for Code Compliance Code: 2012 International Building Code (IBC)