HomeMy WebLinkAboutB13-0508 plans approvedCOVER
INTERNATIONAL RESIDENTIAL CODE 2012
PROJECT SUMMARY:
Zoning:
SINGLE-FAMILY RESIDENCE
Code:
CROSS RENOVATION PERMIT SET
126 FOREST RD. #W VAIL, CO 81657
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS.
2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY
WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR
DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY.
3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN
APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR
AREAS.
4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR
FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE
TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS
OTHERWISE NOTED.
5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE
BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET
ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS.
6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR
TYPES.
7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR
WINDOW TYPES.
8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR
AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS.
9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR
FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE
ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY
IN THE PROJECT.
10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES
AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE
INTERNATIONAL BUILDING CODE AND THE INTERNATIONAL RESIDENTIAL CODE. COMPLIANCE
IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES
NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN IBC AND ALL LOCAL AND REGIONAL
CODES.
11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND
OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR
DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER
STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE
CONSTRUCTION.
12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE
BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE
WORK.
13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK
SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL
PROBLEMS WITH THESE SURFACES.
14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN
APPROVAL.
15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR
AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES,
EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE
INDUSTRY.
16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE
SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY
DISCREPANCIES.
17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING
UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION
IMPACTS TO THE SITE.
18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE
ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL
AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED
LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND
WITH THE NON-DISTURBED LANDSCAPE.
19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER.
20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE
CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR
LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT.
DRAWING INDEX
Detail Area Reference
Elevation Reference
Section Cut Reference
Large Area Detail Reference
12/31/1999
Material Tag
Revision Symbol
Detail Cut Reference
Grid Bubble
Revision Cloud
Elevation Symbol
SYMBOLS:
TYPE R DIV. 3
Occupancy Classification:
ARCHITECT:
K.H. WEBB ARCHITECTS P.C.
710 W. LIONSHEAD CIRCLE, UNIT A
VAIL, CO 81657
PH. 970.477.2990
CONTACTS:
KYLE H. WEBB
DEBRA MONROE
PROJECT TEAM:
A monitored fire alarm system is
required and must comply with NFPA
72(2002) and VFES standards
TYPE V
Construction Type:
STRUCTURAL ENGINEER:
MONROE & NEWELL ENGINEERS, INC.
PH. 970.949.7768
CONTACT:
HANNES SPAEH
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
GENERAL CONTRACTOR:
TRANSWEST CONSTRUCTION, LLC.
PO BOX 8812
AVON, CO 81620
PH. 970.376.6543
CONTACTS:
MIKE SCRIVENS
KYLE HOILAND
OWNER CONTACT:
RON BYRNE
PH. 970.476.1987
ARCHITECTURAL
A 001 1/8" = 1'0"GRFA CALCULATIONS
A 100 1/8" = 1'0"SITE PLAN - PROPOSED
A 101 1/4" = 1'0"GARAGE LEVEL PLAN - EXISTING/PROPOSED
A 102 1/4" = 1'0"NEW BEDROOM LEVEL PLAN - EXISTING/PROPOSED
A 103 1/4" = 1'0"MASTER LEVEL PLAN - EXISTING/PROPOSED
A 104 1/4" = 1'0"LIVING LEVEL PLAN - EXISTING/PROPOSED
A 105 1/4" = 1'0"LOFT PLAN - EXISTING/PROPOSED
A 106 1/4" = 1'0"ROOF PLAN - EXISTING/PROPOSED
A 107 1/4" = 1'0"GARAGE LEVEL REFLECTED CEILING PLAN
A 108 1/4" = 1'0"GUEST LEVEL REFLECTED CEILING PLAN
A 109 1/4" = 1'0"MASTER LEVEL REFLECTED CEILING PLAN
A 110 1/4" = 1'0"LIVING LEVEL REFLECTED CEILING PLAN
A 111 1/4" = 1'0"LOFT LEVEL REFLECTED CEILING PLAN
A 200 1/4" = 1'0"WEST ELEVATION - EXISTING/PROPOSED
A 201 1/4" = 1'0"NORTH ELEVATION - EXISTING
A 202 1/4" = 1'0"NORTH ELEVATION - PROPOSED
A 203 1/4" = 1'0"SOUTHWEST ELEVATION - EXISTING/PROPOSED
A 500 SCALE VARIES DETAILS
CIVIL
1:10 SURVEY
Received
By Carolyn Godfrey at 9:58 am, Dec 13, 2013
B13-0508 CR1
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
NEW
AREA:
840 SQ.
FT.
NEW GRFA
GARAGE
NEW
AREA:
67 SQ. FT.
BASEMENT DEDUCTION
(see SF-1 in Read Residence Remodel)
881 * .19 = 159 sq. ft.
TOTAL
AREA:
839 SQ.
FT.
MECH.
<5'HT.
EXTG GRFA
NEW GRFA
NEW
AREA:
170 SQ.
FT.
TOTAL
AREA:
984 SQ.
FT.
EXTG GRFA
NEW GRFA
NEW
AREA:
171 SQ.
FT.
TOTAL
AREA:
982 SQ.
FT.
EXTG GRFA
NEW GRFA
TOTAL AREA:
318 SQ. FT.
OPEN TO
BELOW,
<16'H
EXTG GRFA
SEC. (40%) PRIM. ( 60%)
GARAGE LEVEL 839 1016
NEW BEDROOM 792
MASTER 984 812
LIVING 982 1309
LOFT 318 755
NET SF 3,915 3,892
GARAGE CR.: -600 -600
BSMNT DED.: -680 -823
TOTAL GRFA:2,635 sf 2,469 sf (5,104)
GRFA CALCULATION:
( SEE SF-1 READ RESIDENCE SET FOR PRIMARY EXHIBITS)
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
1 scale 1/8"=1'-0"
GARAGE LEVEL GRFA 2 scale 1/8"=1'-0"
NEW BEDROOM GRFA 3 scale 1/8"=1'-0"
MASTER GRFA
4 scale 1/8"=1'-0"
LIVING GRFA5scale 1/8"=1'-0"
LOFT GRFA
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
LOT 6
LOT 4
FOUND PLAIN
#5 REBAR
FOREST ROAD (50' R.O.W.)
SEWER
MANHOLE
2' X 2' ROCK
LIGHT POST
25
.
0
0
'
ACCESS EASMENT
RECORDED BOOK 570, PAGE 202
SEWER
MANHOLE
T.O.W.
ENTRYENTRY
GARAGE
ENTRY
ENTRY
UPPER
ENTRY
LOT 3
FLAGSTONE
PATIO
WINDOW
WELLFLAGSTONE
WALK
FLAGSTONE
PATIO
PATIO/SPA
FACE OF
ROCK OUTCROP
10'UTILITY
EASEMENT
UTILITY EASEM
E
N
T
(NO WIDTH DI
M
E
N
S
I
O
N
O
N
P
L
A
T
)
NEW
GARAGE
WALL
NEW
ENTRY
NEW
SNOWMELTED
DRIVE W/
PAVERS
PARKINGSPOT
PARKING
SPOT
PARKING
SPOT
PARKING
SPOT
TO SLAB
97'-8"
DOG
RUN
9' x 19'
45.3
46.9
TREE TO BE
REPLACED
9'X19'
9' x 19'
OLD
GARAGE
WALL
12
%
1
2
%
NO
CH
A
N
G
E
12
%
DR
I
V
E
TRENCH
DRAIN
LINE OF SITE
DISTURBANCE
T.O.W.
11'
-
0
3
8"
T.O.W.
T.O.W.
NEW 3' BOULDER
RETAINING
WALL
DRIVEWAY
CENTERLINE
8%
8%
DRIVEWAY
PERIMETER
B.O.W.
B.O.W.
B.O.W.
EXISTING
WALL TO
REMAIN
B.O.W.
T.O.W.
T.O.W.T.O.W.
T.O.W.
T.O.W.
20
'
-
0
"
15
'
-
0
"
15'-0"
LINE OF SETBACK
15
'
S
E
T
B
A
C
K
15' SETBACK
20
'
S
E
T
B
A
C
K
LIVING LEVEL
DECK ABOVE
TREE TO BE
REPLACED
T.O.W.
T.O.W.
B.O.W.
7.07" rise - 14 steps
1 scale 1/8"=1'-0"
SITE PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
GARAGE
100
TO SLAB
97'-8" TYP.
@ PERIMETER
TO SLAB
97'-8"
ELEV.
TO LANDING
101'- 4"
MECH.ROOM
101
MUD
102
RISE -
6 @ 7.36"
SKI STORAGE
SKI STORAGE
B
E
N
C
H
/
S
K
I
B
O
O
T
S
B
E
L
O
W
C
U
B
B
I
E
S
A
B
O
V
E
FULL-SIZED
WASHER
AND DRYER
LAUNDRY
103
STAIR
104
EXISTING GARAGE WALL
NEW GARAGE WALL 1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
1
100
1
101
1
103
2
100
1
104
6" PIT
RISE - 9 @ 7.4"
T.O. SLAB
98'-3 1/2"
CEILING
HEIGHT
4'-3 15/16"
3'-0"
1
9
'
-
3
12
"
9'
-
8
"
4'-
1
1
78"
312"
4'-
9
"
5'-8
"
3'-
2
1 2"
3'-
8
12"
10
'
-
8
38"
31
2"
4'
-
9
7
8"
3
12"
3
1 2"
3'-7
1
4
"
3 12
"
5'-8
38"
8"6"
19'-
1
0
1 8"
TILE
CON
C
R
E
T
E
SHELVES
H
A
N
G
I
N
G
TILE
WD
,
2
A
3
0
0
STEP
T.O. SLAB
98'-3 1/2"
NEW GARAGE DOOR W/ WINDOWS
BOTTOM OF 1ST STAIR
98'-9 5/8"
3
12"
HAN
G
I
N
G
8"
512"
7.07" RISE - 14 STEPS
OPEN RAIL
THIN VENEER
4" MAX THIN VENEER
4" MAX
VENEER
6"
FLOOR PLAN NOTES:
E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR
OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A
MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND
OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS.
PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE
FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A
WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO
WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING
CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT
AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER
WHERE IS SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE.
1
1
TYPE X GYP
UNDER
STAIRS, TYP.
EXTG. STAIR
RAILING TO
REMAIN
GARAGE
XXX
TO SLAB
102'-0" TYP.
@ PERIMETER
TO SLAB
102'-6"
TO SLAB
102'-0"
ELEV.
TO LANDING
107'-4 1/2"
CRAWL
SPACE
5'-0"
HEAD
HEIGHT
T.O. GYPCRETE
110'-6"
UP
U
P
1
A201
2
A200
2
A203
1 scale 1/4"=1'-0"
GARAGE LEVEL FLOOR PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
2 scale 1/4"=1'-0"
GARAGE LEVEL FLOOR PLAN - EXISTING
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
JR. MASTER
BEDROOM
205
GUEST
202
T.O. STONE
111'-5 5/8"
T.O. FINISH FLOOR
106'-10 5/8"
U
P
TO SLAB
97-8"
ELEV.
LIVING DECK ABOVE
OPEN RAIL,
NEW DECK
BENCH
GALLERY
206
G. BATH
200 DN
ENTRY
PORCH
RISE - 8@ 6.9"
TV
7.07" rise - 14 steps
B
U
I
L
T
-
I
N
W
A
R
D
R
O
B
E
TV
NOOK
CLOSET
201
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
JR. BATH
203
9
1
200
1
202
1
201
2
206
1
205
1
203
1
204
1
206JR. W.C.
204
RISE - 8@ 6.9"
EXISTING RETAINING
WALL TO REMAIN312"
3'-8
12"
31
2"
12'-8
12
"
5 12
"
2'-
0
1 4"
6'-2
12"
8'-
1
1 8"
2'-1
58"
9'-4
1
4
"
8'-9
5
8"
3'
-
0
"
3'-1"
312"
3 1
2"
7'-11
1
4"
6'-
7
1 4"
3
12"
14
'
-
3
"
1'
-
0
"
2'-
1
0
78"
3 1
2"
4'
-
8
12
"
1'-1
1
58"
5'-1
0
3 4"
3'-0
"31 2"
3'-
0
1 8"
21
'
-
1
1
7 8"
C
P
T
.
W
D
,
CP
T
.
WD
,
CP
T
.
TIL
E
CP
T
.
TIL
E
2A
3
0
0
BOTTOM OF 1ST STAIR
98'-9 5/8"
TIERED PLANTERS
TIERED PLANTERS
TIERED PLANTERS
GARAGE WALL BELOW
THIN VENEER
4" MAX THIN VENEER
4" MAX
VENEER 6"
CLOSET
207
38 SQ. FT.
1
207
1' SILL
FLOOR PLAN NOTES:
E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR
OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A
MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND
OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS.
PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE
FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A
WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO
WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING
CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT
AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER
WHERE IS SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE.
1
E
E
4'-0
3 4"
3'-
8
12"
31 2"
12
'
-
3
5 8"
SLOPING
NEW COL., RE:STRUCT
1
1 scale 1/4"=1'-0"
NEW BEDROOM LEVEL FLOOR PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
MASTER
SUITE
303
MASTER
BATH
304
GUEST
301
T.O. STONE
121'-0"
T.O. GYPCRETE
116'-0"
UP
ELEV.
DECK ABOVE
NEW DECK BELOW
ST
A
C
K
A
B
L
E
W/
D
IN
B
U
I
L
T
-
I
N
C
A
B
I
N
E
T
CLOSET
306
MASTER
W.C.
305
NEW
AREA:
170 SQ.
FT.
VIEWVIEW
DNEXISTING
BATH TO
REMAIN
EXISTING
CLOSET TO
REMAIN
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
F.P.
WARDROBE
TV
CLOSET #2
302
1
307
G.BATH
300
HALLWAY#3
307
1
301
1
303
1
302
1
304
1
305
1
306
EXISTING
BAY WINDOWS
TO REMAIN
RISE - 8@ 7.25"
RISE - 8@ 7.25"
SLAB
ON
GRADE
NEW FRENCH BALCONY, RAILING TO
MATCH EXTG HOUSE RAILINGS
BENCH
SLOT DRAIN
SLOT DRAIN
9'-5"
31
2"
4'-6
14"
31
2"
1
3
'
-
6
14"
5 12"
2'
-
1
0
1
4
"
3'-4
3
8 "
8'-10
1
8
"
2'-
8
58"
4'-
8
1 8"
4'-8
1 8"
11'-
1
18"
6'-
1
3 4"
23'-6"
4'-
2
"
6'-5
1 2"
3'-
9
18"
31 2"
12
'
-
7
18"
512"
312"4'-2
12"
5
12"
6'-
9
1 2"
512"
1
3
'
-
8
7
8"
312"
2'-0"
3'-6"
2'-4
1
8
"
1'
-
2
"
51
2 "
9'-0
1
8
"
8'-
1
1 4"
51 2"
3'-
4
1 4"31 2"
1'-
6
"
5'
-
8
12"
3 1
2
"
51 2"
15'-
1
3 4"
1'-
6
"
312"
11
'
-
5
1 2"
51 2"
TV
W/
HYD.
ARM SOAP NICHE
SOAP NICHE
C
P
T
.
W
D
.
CPT.
TI
L
E
CPT.
TI
L
E
CPT
.
WD.
CP
T
.
TIL
E
2A
3
0
0
1
1
EXTG RAILING TO REMAIN, TYP.
FLOOR PLAN NOTES:
E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR
OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A
MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND
OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS.
PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE
FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A
WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO
WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING
CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT
AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER
WHERE IT SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE.
TYP. EXTERIOR WALL CONSTRUCTION - WOOD:
-1x V-GROOVE CEDAR SIDING, STAINED TO MATCH EXTG.
-WATER REPELLENT BARRIER OR 30# FELT
-1/2" PLYWOOD SHEATHING
-2x FRAMING
-R-21 MIN BATT INSULATION
-VAPOR BARRIER AT INTERIOR
-5/8" GYPSUM BOARD
1
2
2
2
E
L
E
V
.
MASTER
BEDROOM
XXX
MASTER
BATH
XXX
CLOSET
XXX
BEDROOM #2
XXX
BATH #2
XXX
T.O. STONE
121'-0"
T.O. GYPCRETE
116'-0"
UP
TO SLAB
102'-0"
DN
DECK ABOVE
TOTAL
EXISTING
AREA:
814 SQ.
FT.
1
A200
1
A201
2
A203
4'-9
1
2"
3'-
8
1 2"
1 scale 1/4"=1'-0"
MASTER LEVEL FLOOR PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
2 scale 1/4"=1'-0"
MASTER LEVEL FLOOR PLAN - EXISTING
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
ELEV.
LIVING
403
KITCHEN
401
131'-0"
T.O. STONE
TO STONE
125'-11"
T.O. GYPCRETE
126'-0"
UP
TO STONE
125'-11"
DN
DECK
DECK
POWDER
400
NEW TRACK
SLIDING
4 PANEL
POCKET
DOOR
32"X32" "BENTO" FIRE
PIT BY PALOFORM, PROVIDE
NEW NATURAL GAS QUICK
CONNECT AS NECESSARY
WIRED FOR
HOT
TUB
OUTDOOR
LIVING
406
DOG
RUN
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
B
B
Q
9
EXISTING
BAY WINDOWS
TO REMAIN
DINING
402
1
302
HALLWAY#4
405
RISE - 8@ 7.7"
EXPOSED STRUCTURAL BEAM
ABOVE
REFRIGERATOR
9
8"
6'-5
1 2"
4"51 2"
4'-0
"
5
1 2"
134"
4'-1
12"
5'-2
1 2"
5'-
8
34"
14'-
1
"
5'-2
3
8"
7'
-
0
"
3
1 2"
EXISTING
POWDER
ROOM TO
REMAIN
5'-8
1 4"
1"
4'-8
5
8"
1"
5'-3"
18'-4"
5 1
2"
INVISIBLE
SCREEN - SPLIT
FROM MIDDLE
BUILT-IN
COUNTER
BUILT-IN
COUNTER
GRANITE
COUNTERTOPS -
DBL THICK EDGE
NEW WALNUT
FLOORING
THROUGHOUT
W
D
.
W
D
.
2A
3
0
0
PO
P
-
U
P
T
V
NEW AREA OPEN
TO ABOVE
RANGE
DRY
BAR
XXX
FLOOR PLAN NOTES:
E PER IRC SECTION R310: EGRESS WINDOW SHALL HAVE A NET CLEAR
OPENING OF 5.7SF MIN., WITH A SILL HT. OF NOT MORE THAN 44" AFF, A
MIN CLR OPENING HT. OF 24", MIN CLR OPENING WIDTH OF 20", AND
OPERATIONAL FROM THE INSIDE WITHOUT THE USE OF KEYS OR TOOLS.
PER IRC SECTION R311: 36"H HAND/GUARD RAIL AS MEASURED ABOVE
FINISHED FLOOR OR FINISHED STAIR NOSING. WHERE ADJACENT TO A
WALL, RAIL SHALL BE MIN. 1 12" MIN. OFF FIN. WALL AND SHALL RETURN TO
WALL AT TERMINATION POINTS. WHERE GUARD RAILING, RAILIING
CONSTRUCTION SHALL NOT ALLOW THE PASSAGE OF A 4" SPHERE EXCEPT
AT TRIANGULAR OPENINGS CREATED BY THE RAILING, TREAD, AND RISER
WHERE IT SHALL NOT ALLOW THE PASSAGE OF A 6" SPHERE.
TYP. EXTERIOR WALL CONSTRUCTION - WOOD:
-1x V-GROOVE CEDAR SIDING, STAINED TO MATCH EXTG.
-WATER REPELLENT BARRIER OR 30# FELT
-1/2" PLYWOOD SHEATHING
-2x FRAMING
-R-21 MIN BATT INSULATION
-VAPOR BARRIER AT INTERIOR
-5/8" GYPSUM BOARD
1
16
'
-
7
34"
FD
FD
FD
FD
FD
FD
FD
FD
RELOCATE
EXTG FLOOR
DRAIN
RELOCATE
EXTG FLOOR
DRAIN
PROVIDE NEW 24"x4"
OVERFLOW SCUPPER
THROUGH WALL
DIRECT VENT LINEAR
GAS FIRPLACE
NEW RANGE W/
DOWNDRAFT
EXHAUST THROUGH
EXTERIOR WALL
NEW RAILING TO MATCH EXTG,1
EXTG RAILING TO REMAIN
W5
x
1
6
FILL W-FLANGE WEBS W/ RS
RED CEDAR, STAIN
SLIMLINE INFRARED
PATIO HEATERS BY
INFRATECH
8"
3'-7
58"
1
1
1
2"
13'-4"
5'-5
1
2"
W5
x
1
6
W8x18 BEAMS OVHD,
B.O. BEAM +9'-4", AFF
2
2
2
NEW HOOD LESS
THAN 400CFM FLOW
RATE, NO MAKE-UP
AIR
MECHANICAL
FLUE
ELEV.
LIVING
XXX
KITCHEN
XXX
POWDER
XXX
131'-0"
T.O. STONE
TO STONE
125'-11"
T.O. GYPCRETE
126'-0"
UP
D/W
TO STONE
125'-11"
OPEN TO
ENTRY
BELOW
TOTAL
EXISTING
AREA:
821 SQ.
FT.
1
A2001
A201
2
A203
FD
FD
FD
FD
FD
FD
FD
FD
WALL DRAIN
W
A
L
L
D
R
A
I
N
H
O
T
T
U
B
?
REMOVE
EXTG.
WINDOW
RELOCATE
EXTG FLOOR
DRAIN
RELOCATE
EXTG FLOOR
DRAIN
1 scale 1/4"=1'-0"
MAIN LEVEL FLOOR PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
12.06.13
2 scale 1/4"=1'-0"
MAIN LEVEL FLOOR PLAN - EXISTING
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
DN
LOFT
500
T.O. GYPCRETE
136'-0"
T.O. STONE
135'-11"
OPEN TO
BELOW,
<16'H
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
EXISTING
WINDOW
TO REMAIN
EXISTING
WINDOW
TO REMAIN
EXISTING
BAY WINDOWS
TO REMAIN
1
5011
500
LOFT BATH
501
EXISTING
DOOR
TO REMAIN
312"
2'-
7
34"
31 2"5 1
2"
3 12
"
1'
-
6
"
CL
O
S
E
T
EXISTING
LOFT TO
REMAIN
NEW LOFT
BATH
LAYOUT.
VFY.
FIXTURES
W/CLIENT
6'-6
"
8'-6
3 4"
6'-7
1 2"
7'-
7
58"
6'-5"
3'-4"
3'-4"
3'-4"
6'-3
1
2"
TILE
WD.
W
D
.
W
D
.
2
A
3
0
0
NEW RAILING
EXTG RAILING TO REMAIN
DN
LOFT
XXX
T.O. GYPCRETE
136'-0"
T.O. STONE
135'-11"
OPEN TO BELOW
TOTAL
EXISTING
AREA:
377 SQ.
FT.
CL
O
S
E
T
1
A200
1
A201
2
A203
1 scale 1/4"=1'-0"
LOFT LEVEL FLOOR PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
2 scale 1/4"=1'-0"
LOFT LEVEL FLOOR PLAN - EXISTING
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
1
A200
1
A202
1
A203
1'-0
3 4"
2'-
1
1
3 8"
8'-
0
58"
9'-
0
3 8"
1'-
1
1
5 8"
8'-
1
7 8"
22'-10"
11'-9
12"
522)
PITCH
522)
PITCH
NEW CEDAR SHAKE ROOF TO
0$7&+(;,67,1*VI
NEW SNOW RETENTION BARS TO
MATCH EXTG.
TYPICAL ROOF CONSTRUCTION:
-CEDAR SHAKE SHINGLES TO MATCH
EXISTING ROOF
-WATERPROOF MEMBRANE
-58" CDX PLYWOOD
-R-49 MIN BATT INSULATION
-VAPOR BARRIER
-58" GYP. BD.
1
A200
21
A201
2
A203
1 scale 1/4"=1'-0"
ROOF PLAN - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
2 scale 1/4"=1'-0"
ROOF PLAN - EXISTING
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
GARAGE
XXX
TO SLAB
102'-0" TYP.
@ PERIMETER
TO SLAB
102'-6"
TO SLAB
102'-0"
ELEV.
TO LANDING
107'-4 1/2"
CRAWL
SPACE
5'-0"
HEAD
HEIGHT
T.O. GYPCRETE
110'-6"
UP
UP
TOTAL
EXISTING
AREA:
756 SQ.
FT.
1
A201
2
A200
2
A203
S S S
J
J
,
,
GFI
220
GFI220
EFTHUL
I
I I
I
I
I
I
,
S
S
R
R
3
3
6
WATER
COP
HEATER
GARAGE
100
TO SLAB
97'-8" TYP.
@ PERIMETER
TO SLAB
97'-8"
ELEV.
TO LANDING
101'- 4"
MECH.ROOM
101
MUD
102
RISE -
6 @ 7.36"
LAUNDRY
103
STAIR
104
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
1
100
1
101
1
103
2
100
1
104
RISE - 9 @ 7.4"
T.O. SLAB
98'-3 1/2"
3'
-
0
"
19'-3
12"
9'-8"
4'-
1
1
78"
312"
4'-
9
"
5'-8
"
3'-
2
12"
3'-
8
12"
10'-
8
38"
3 1
2"
4'
-
9
7
8"
312"
3
1 2"
3'-7
14"
312"
5'-
8
38"
8"6"
19'-
1
0
1 8"
TILE
CON
C
R
E
T
E
TILE
WD,
2
A
3
0
0
T.O. SLAB
98'-3 1/2"
BOTTOM OF 1ST STAIR
98'-9 5/8"
31 2"
8"
512"
7.07" RISE - 14 STEPS
I
I
I
I
R
R
I
D
D
D
D
D
D
D
J
J
D-
D-
D-
D-
D-
GFI220
GFI220
6
I
D-
RCP/ELECTRICAL KEY:
SMOKE DETECTOR LOCATION
CARBON MONOXIDE DETECTOR
LOCATION; TO BE INSTALLED PER THE
STATE OF COLORADO REGULATIONS
(HARDWIRED)
S
CO
GENERAL ELECTRICAL NOTES:
1. TYPICAL COLOR OF OUTLETS,
SWITCHES, AND COVERS, VFY.
2. POWER AND LIGHTING DISTRIBUTION
TO FOLLOW REQUIREMENTS PER 2012
IRC
3. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
4. VERIFY ALL FLOOR OUTLET LOCATIONS
WITH FINAL FURNITURE LAYOUTS
5. VERIFY HEIGHTS OF RECEPTACLES FOR
TVs WITH FINAL FURNITURE LAYOUTS.
6. VERIFY MANUF. POWER REQUIREMENTS
FOR ALL APPLIANCES.
7. PROVIDE LOCK BOXES FOR FIRE DEPT.
AT EACH UNIT
8. DEMOLITION ELECTRICAL DEPICTED IN
DRAWING WITH DASHED LINES. NEW
ELECTRICAL DEPICTED IN DRAWING
WITH SOLID LINES.
LIGHTING SYMBOLS
C
A
RECESSED LENSED SHOWER LIGHT: MR 16
4" DOWNLIGHT
RECESSED CAN LIGHT: MR 16
B L
4" LENSED DOWNLIGHT
D
UNDER-CABINET LIGHT
F
UCH
J-BOX / DECORATIVE PENDANT LIGHT
J
K
DECORATIVE WALL-MOUNTED SCONCE
LENSED WHERE NOTED; LED WHERE NOTED
LEDCOVE LIGHTING L
M LED PUCK-LIGHT
N CEILING MOUNT
K
I FLUORESCENT LIGHTING
EXTERIOR SCONCER
VANITY MIRROR W/ BUILT-IN LIGHTS
SPEAKERSP
BATHROOM EXHAUST FANEF
EXHAUST FAN/LIGHT COMBO
GROUND FAULT DUPLEX OUTLET @ +42" U.O.N.
U SMOKE DETECTOR
DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N.
GFI 220 OUTLET220
MOTION SWITCHMS
CENTERED IN BASEBD U.O.N.
QUAD. OUTLET, MNT. HORIZ.
CENTERED IN BASEBD U.O.N.
WALL MOUNTED TELEPHONE OUTLET
RECESSED FLOOR OUTLET
6 THERMOSTAT
TV 2 RG6 COAXIAL
LIGHTING CONTROLS KEYPAD LOCATIONKEY
LIGHTING CONTROLS CIRCUIT###
* DENOTES WIRELESS TABLETOP MODEL
E
G L RECESSED LENSED SHOWER LIGHT: MR16
4" LENSED DOWNLIGHT
CEILING FAN WIRING
LUTRON Q (OR SIM.) KEY PAD
LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND-
4" DOWNLIGHT
NEW RECESSED CAN LIGHT: LED
KEY
DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N.
VFY. W/ TILE LAYOUTSRECESSED CAN LIGHT: LIGHT 6"
O 4" ADJUSTABLE
RECESSED CAN LIGHT: LED ART LIGHT
TRACK LIGHTINGT
UPLIGHTU
W RECESSED WALL STEP-LIGHT *
12" A.F.F. - LED
*
*
Y*IN FLOOR LIGHT
*4" ADJUSTABLE
RECESSED CAN LIGHT: LED
S SWITCH
DS SWITCH DIMMER
3S 3 WAY SWITCH
RECESSED LENSED SHOWER LIGHT:
6" LENSED DOWNLIGHT
L
JS JAMB SWITCH
,J BOXS4" LENSED DOWNLIGHT
RECESSED LENSED LIGHT: LED L
2 scale 1/4"=1'-0"
GARAGE LEVEL RCP - EXISTING 1 scale 1/4"=1'-0"
GARAGE LEVEL RCP - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
JR. MASTER
BEDROOM
205
GUEST
202
T.O. STONE
111'-5 5/8"
T.O. FINISH FLOOR
106'-10 5/8"
UP
TO SLAB
97-8"
ELEV.
BENCH
GALLERY
206
G. BATH
200 DN
ENTRY
PORCH
RISE - 8@ 6.9"
CLOSET
201
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
JR. BATH
203
1
200
1
202
1
201
2
206
1
205
1
203
1
204
1
206JR. W.C.
204
RISE - 8@ 6.9"
312"
3'
-
8
12"
3 1
2"
12'-8
12"
51
2"
2'-
0
1 4"
6'-2
12"
8'-
1
1 8"
2'-1
58
"
9'-4
1
4
"
8'-9
5
8 "
3'
-
0
"
3'-1"
3
12"
31
2"
7'
-
1
1
1
4"
6'-
7
1 4"
312"
14
'
-
3
"
1'-0"
2'-1
0
78"
3 12"
4'
-
8
12"
1'-
1
1
58"
5'-
1
0
34"
3'-0
"3
12"
3'-
0
1 8"
21'-
1
1
7 8"
CPT.
W
D
,
CPT
.
W
D
,
CP
T
.
TILE
CP
T
.
TIL
E
2A
3
0
0
BOTTOM OF 1ST STAIR
98'-9 5/8"
CLOSET
207
1
207
4'-0
3 4"
3'-
8
1 2"
3
1 2"
12
'
-
3
5 8"R
W
W
W
W
W
W
O
O
O
C
C
C
C
C
C
O
E
E
D-
C
C
C
C
C
J
J
C
EF
C
C
C
BL
D-
D-
D-
D-
D-
D-
D-C
C
C
C
C
C
C
E
E
J
D-
EF
C
C
C
C
C
R
D-
D-
D-
D-
D-
D-
C
C
D-
D-
T
V
D-
D-
D-
D-
TV
U
U
C
O
C
O
RCP/ELECTRICAL KEY:
SMOKE DETECTOR LOCATION
CARBON MONOXIDE DETECTOR
LOCATION; TO BE INSTALLED PER THE
STATE OF COLORADO REGULATIONS
(HARDWIRED)
S
CO
GENERAL ELECTRICAL NOTES:
1. TYPICAL COLOR OF OUTLETS,
SWITCHES, AND COVERS, VFY.
2. POWER AND LIGHTING DISTRIBUTION
TO FOLLOW REQUIREMENTS PER 2012
IRC
3. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
4. VERIFY ALL FLOOR OUTLET LOCATIONS
WITH FINAL FURNITURE LAYOUTS
5. VERIFY HEIGHTS OF RECEPTACLES FOR
TVs WITH FINAL FURNITURE LAYOUTS.
6. VERIFY MANUF. POWER REQUIREMENTS
FOR ALL APPLIANCES.
7. PROVIDE LOCK BOXES FOR FIRE DEPT.
AT EACH UNIT
8. DEMOLITION ELECTRICAL DEPICTED IN
DRAWING WITH DASHED LINES. NEW
ELECTRICAL DEPICTED IN DRAWING
WITH SOLID LINES.
LIGHTING SYMBOLS
C
A
RECESSED LENSED SHOWER LIGHT: MR 16
4" DOWNLIGHT
RECESSED CAN LIGHT: MR 16
B L
4" LENSED DOWNLIGHT
D
UNDER-CABINET LIGHT
F
UCH
J-BOX / DECORATIVE PENDANT LIGHT
J
K
DECORATIVE WALL-MOUNTED SCONCE
LENSED WHERE NOTED; LED WHERE NOTED
LEDCOVE LIGHTING L
M LED PUCK-LIGHT
N CEILING MOUNT
K
I FLUORESCENT LIGHTING
EXTERIOR SCONCER
VANITY MIRROR W/ BUILT-IN LIGHTS
SPEAKERSP
BATHROOM EXHAUST FANEF
EXHAUST FAN/LIGHT COMBO
GROUND FAULT DUPLEX OUTLET @ +42" U.O.N.
U SMOKE DETECTOR
DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N.
GFI 220 OUTLET220
MOTION SWITCHMS
CENTERED IN BASEBD U.O.N.
QUAD. OUTLET, MNT. HORIZ.
CENTERED IN BASEBD U.O.N.
WALL MOUNTED TELEPHONE OUTLET
RECESSED FLOOR OUTLET
6 THERMOSTAT
TV 2 RG6 COAXIAL
LIGHTING CONTROLS KEYPAD LOCATIONKEY
LIGHTING CONTROLS CIRCUIT###
* DENOTES WIRELESS TABLETOP MODEL
E
G L RECESSED LENSED SHOWER LIGHT: MR16
4" LENSED DOWNLIGHT
CEILING FAN WIRING
LUTRON Q (OR SIM.) KEY PAD
LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND-
4" DOWNLIGHT
NEW RECESSED CAN LIGHT: LED
KEY
DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N.
VFY. W/ TILE LAYOUTS
RECESSED CAN LIGHT: LIGHT 6"
O 4" ADJUSTABLE
RECESSED CAN LIGHT: LED ART LIGHT
TRACK LIGHTINGT
UPLIGHTU
W RECESSED WALL STEP-LIGHT *
12" A.F.F. - LED
*
*
Y*IN FLOOR LIGHT
*4" ADJUSTABLE
RECESSED CAN LIGHT: LED
S SWITCH
DS SWITCH DIMMER
3S 3 WAY SWITCH
RECESSED LENSED SHOWER LIGHT:
6" LENSED DOWNLIGHT
L
JS JAMB SWITCH
,J BOXS4" LENSED DOWNLIGHT
RECESSED LENSED LIGHT: LED L
1 scale 1/4"=1'-0"
NEW BEDROOM LEVEL RCP - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
E
L
E
V
.
MASTER
BEDROOM
XXX
MASTER
BATH
XXX
CLOSET
XXX
BEDROOM #2
XXX
BATH #2
XXX
T.O. STONE
121'-0"
T.O. GYPCRETE
116'-0"
UP
TO SLAB
102'-0"
DN
TOTAL
EXISTING
AREA:
814 SQ.
FT.
1
A200
1
A201
2
A203
4'-9
12"
3'-
8
1 2"
D
D
D
D
3
D
S
3
D
S
S
3
D
S S
S 3D
S
R
FL
J
DSSSEF
DSDS6
TV
TV
D
DD
D
J
J
DS
VOLUME
JS
I
U
S
S
S
S
A
A
A
A
A
A
A
3
D
S3D
S3D
A
A
3
D
D
SP
SP
SP
S DA
6 SDSD
J
J
EF
SDS
D
D
D
FL
FL
D
D
MASTER
SUITE
303
MASTER
BATH
304
GUEST
301
T.O. STONE
121'-0"
T.O. GYPCRETE
116'-0"
UP
ELEV.
CLOSET
306
MASTER
W.C.
305
NEW
AREA:
170 SQ.
FT.
DN
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
CLOSET #2
302
1
307
G.BATH
300
HALLWAY#3
307
1
301
1
303
1
302
1
304
1
305
1
306
RISE - 8@ 7.25"
RISE - 8@ 7.25"
SLAB
ON
GRADE
9'-5"
312"4'-6
1
4"
3 1
2"
13'-6
1
4
"
512"
2'
-
1
0
1
4
"
3'-4
3
8"
8'-10
18"
2'-
8
5 8"
4'-
8
18"
4'-8
18"
11
'
-
1
1 8"
6'-
1
34"
23'-6"
4'-
2
"
6'-5
12"
3'-
9
18"
3
1 2"
12
'
-
7
18"
5
1 2"
3
1 2"4'-
2
1 2"
51 2"
6'-9
12"
5
1 2"
13'-8
78
"
3 1
2"
2'-0"
3'-6"
2'-4
1
8 "
1'-2"
5 12
"
9'-0
1
8 "
8'-
1
1 4"
5
12"
3'-
4
14"31 2"
1'-
6
"
5'-8
1
2"
3 1
2 "
5
1 2"
15
'
-
1
3 4"
1'-
6
"
3
1 2"
11'-
5
12"
5
1 2"
C
P
T
.
WD.
CPT.
TI
L
E
CPT.
TI
L
E
CP
T
.
WD
.
CP
T
.
TILE
2
A
3
0
0
C
EXISTING
SWITCH LEGS
AND WIRING
TO REMAIN.
VFY NEW
FIXTURES
W/ CLIENT.
EXISTING
SWITCH LEGS
AND WIRING
TO REMAIN.
VFY NEW
FIXTURES
W/ CLIENT.
C
C
C
C
C
E
E
D-
D-
D-
D-
C
C
C
C
D-
TV
D-
D-
D-
E
D-
E
C
C
C
C
C
C
C
C
D-
D-
C
D-
C
C
C
C
C
C
C
D-
C
C
C
C
C
J
J
J
C
R
D-
R
C
GFI220
D-
D-
D-
SL
SL
D-
D-
RCP/ELECTRICAL KEY:
SMOKE DETECTOR LOCATION
CARBON MONOXIDE DETECTOR
LOCATION; TO BE INSTALLED PER THE
STATE OF COLORADO REGULATIONS
(HARDWIRED)
S
CO
GENERAL ELECTRICAL NOTES:
1. TYPICAL COLOR OF OUTLETS,
SWITCHES, AND COVERS, VFY.
2. POWER AND LIGHTING DISTRIBUTION
TO FOLLOW REQUIREMENTS PER 2012
IRC
3. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
4. VERIFY ALL FLOOR OUTLET LOCATIONS
WITH FINAL FURNITURE LAYOUTS
5. VERIFY HEIGHTS OF RECEPTACLES FOR
TVs WITH FINAL FURNITURE LAYOUTS.
6. VERIFY MANUF. POWER REQUIREMENTS
FOR ALL APPLIANCES.
7. PROVIDE LOCK BOXES FOR FIRE DEPT.
AT EACH UNIT
8. DEMOLITION ELECTRICAL DEPICTED IN
DRAWING WITH DASHED LINES. NEW
ELECTRICAL DEPICTED IN DRAWING
WITH SOLID LINES.
LIGHTING SYMBOLS
C
A
RECESSED LENSED SHOWER LIGHT: MR 16
4" DOWNLIGHT
RECESSED CAN LIGHT: MR 16
B L
4" LENSED DOWNLIGHT
D
UNDER-CABINET LIGHT
F
UCH
J-BOX / DECORATIVE PENDANT LIGHT
J
K
DECORATIVE WALL-MOUNTED SCONCE
LENSED WHERE NOTED; LED WHERE NOTED
LEDCOVE LIGHTING L
M LED PUCK-LIGHT
N CEILING MOUNT
K
I FLUORESCENT LIGHTING
EXTERIOR SCONCER
VANITY MIRROR W/ BUILT-IN LIGHTS
SPEAKERSP
BATHROOM EXHAUST FANEF
EXHAUST FAN/LIGHT COMBO
GROUND FAULT DUPLEX OUTLET @ +42" U.O.N.
U SMOKE DETECTOR
DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N.
GFI 220 OUTLET220
MOTION SWITCHMS
CENTERED IN BASEBD U.O.N.
QUAD. OUTLET, MNT. HORIZ.
CENTERED IN BASEBD U.O.N.
WALL MOUNTED TELEPHONE OUTLET
RECESSED FLOOR OUTLET
6 THERMOSTAT
TV 2 RG6 COAXIAL
LIGHTING CONTROLS KEYPAD LOCATIONKEY
LIGHTING CONTROLS CIRCUIT###
* DENOTES WIRELESS TABLETOP MODEL
E
G L RECESSED LENSED SHOWER LIGHT: MR16
4" LENSED DOWNLIGHT
CEILING FAN WIRING
LUTRON Q (OR SIM.) KEY PAD
LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND-
4" DOWNLIGHT
NEW RECESSED CAN LIGHT: LED
KEY
DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N.
VFY. W/ TILE LAYOUTS
RECESSED CAN LIGHT: LIGHT 6"
O 4" ADJUSTABLE
RECESSED CAN LIGHT: LED ART LIGHT
TRACK LIGHTINGT
UPLIGHTU
W RECESSED WALL STEP-LIGHT *
12" A.F.F. - LED
*
*
Y*IN FLOOR LIGHT
*4" ADJUSTABLE
RECESSED CAN LIGHT: LED
S SWITCH
DS SWITCH DIMMER
3S 3 WAY SWITCH
RECESSED LENSED SHOWER LIGHT:
6" LENSED DOWNLIGHT
L
JS JAMB SWITCH
,J BOXS4" LENSED DOWNLIGHT
RECESSED LENSED LIGHT: LED L
2 scale 1/4"=1'-0"
MASTER LEVEL RCP - EXISTING 1 scale 1/4"=1'-0"
MASTER LEVEL RCP - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
ELEV.
LIVING
XXX
KITCHEN
XXX
POWDER
XXX
131'-0"
T.O. STONE
TO STONE
125'-11"
T.O. GYPCRETE
126'-0"
UP
D/W
TO STONE
125'-11"
OPEN TO
ENTRY
BELOW
TOTAL
EXISTING
AREA:
821 SQ.
FT.
1
A200
1
A201
2
A203
FD
FD
J
EF DS
S
D
D
D
U
D
S
S
D S
D
D
D
D
D
D
D
SP
D
GFI220
GFI220
SDVOLUME
SS
U
C
H
U
C
H 6J
J
J
DSSSS
K
S
D
VOLUME
R
R
GL
SDF/P
TV
S
S
R
R
E
L
E
V
.
LIVING
403
KITCHEN
401
131'-0"
T.O. STONE
TO STONE
125'-11"
T.O. GYPCRETE
126'-0"
UP
TO STONE
125'-11"
DN
DECK
DECK
POWDER
400
WIRED FOR
HOT
TUB
OUTDOOR
LIVING
406
DOG
RUN
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
B
B
Q
DINING
402
1
302
HALLWAY#4
405
RISE - 8@ 7.7"
8"
6'-5
12"
4"5
1 2"
4'-
0
"
51 2"
134"
4'-
1
1 2"
5'-
2
12"
5'-8
3 4"
14
'
-
1
"
5'-2
3
8"
7'-0"
31 2"
5'-8
1 4"
1"
4'-8
58"
1"
5'-3"
18'-4"
5 1
2
"
W
D
.
W
D
.
2
A
3
0
0
RANGE
DRY
BAR
XXX
16'-
7
3 4"
W5
x
1
6
8
"
3'-7
58"
11 1
2"
13'-4"
5'-5
1
2"
W5
x
1
6
R
R
R
R
K
K
C
C
C
CC
CC
C
C C
C
EXISTING
SWITCH LEGS
AND WIRING
TO REMAIN.
VFY NEW
FIXTURES
W/ CLIENT.
CC
C
K
J
J
J
RR
RR
D-
D-
D-
D-
UC
UC
UC
EXISTING
SWITCH LEGS
AND WIRING
TO REMAIN.
VFY NEW
FIXTURES
W/ CLIENT.
J
J
D-
J
J
D-
D-
D-
6
D-
D-
UC
UC
UC
C
D-
GFI
220
TV
D-
RCP/ELECTRICAL KEY:
SMOKE DETECTOR LOCATION
CARBON MONOXIDE DETECTOR
LOCATION; TO BE INSTALLED PER THE
STATE OF COLORADO REGULATIONS
(HARDWIRED)
S
CO
GENERAL ELECTRICAL NOTES:
1. TYPICAL COLOR OF OUTLETS,
SWITCHES, AND COVERS, VFY.
2. POWER AND LIGHTING DISTRIBUTION
TO FOLLOW REQUIREMENTS PER 2012
IRC
3. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
4. VERIFY ALL FLOOR OUTLET LOCATIONS
WITH FINAL FURNITURE LAYOUTS
5. VERIFY HEIGHTS OF RECEPTACLES FOR
TVs WITH FINAL FURNITURE LAYOUTS.
6. VERIFY MANUF. POWER REQUIREMENTS
FOR ALL APPLIANCES.
7. PROVIDE LOCK BOXES FOR FIRE DEPT.
AT EACH UNIT
8. DEMOLITION ELECTRICAL DEPICTED IN
DRAWING WITH DASHED LINES. NEW
ELECTRICAL DEPICTED IN DRAWING
WITH SOLID LINES.
LIGHTING SYMBOLS
C
A
RECESSED LENSED SHOWER LIGHT: MR 16
4" DOWNLIGHT
RECESSED CAN LIGHT: MR 16
B L
4" LENSED DOWNLIGHT
D
UNDER-CABINET LIGHT
F
UCH
J-BOX / DECORATIVE PENDANT LIGHT
J
K
DECORATIVE WALL-MOUNTED SCONCE
LENSED WHERE NOTED; LED WHERE NOTED
LEDCOVE LIGHTING L
M LED PUCK-LIGHT
N CEILING MOUNT
K
I FLUORESCENT LIGHTING
EXTERIOR SCONCER
VANITY MIRROR W/ BUILT-IN LIGHTS
SPEAKERSP
BATHROOM EXHAUST FANEF
EXHAUST FAN/LIGHT COMBO
GROUND FAULT DUPLEX OUTLET @ +42" U.O.N.
U SMOKE DETECTOR
DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N.
GFI 220 OUTLET220
MOTION SWITCHMS
CENTERED IN BASEBD U.O.N.
QUAD. OUTLET, MNT. HORIZ.
CENTERED IN BASEBD U.O.N.
WALL MOUNTED TELEPHONE OUTLET
RECESSED FLOOR OUTLET
6 THERMOSTAT
TV 2 RG6 COAXIAL
LIGHTING CONTROLS KEYPAD LOCATIONKEY
LIGHTING CONTROLS CIRCUIT###
* DENOTES WIRELESS TABLETOP MODEL
E
G L RECESSED LENSED SHOWER LIGHT: MR16
4" LENSED DOWNLIGHT
CEILING FAN WIRING
LUTRON Q (OR SIM.) KEY PAD
LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND-
4" DOWNLIGHT
NEW RECESSED CAN LIGHT: LED
KEY
DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N.
VFY. W/ TILE LAYOUTS
RECESSED CAN LIGHT: LIGHT 6"
O 4" ADJUSTABLE
RECESSED CAN LIGHT: LED ART LIGHT
TRACK LIGHTINGT
UPLIGHTU
W RECESSED WALL STEP-LIGHT *
12" A.F.F. - LED
*
*
Y*IN FLOOR LIGHT
*4" ADJUSTABLE
RECESSED CAN LIGHT: LED
S SWITCH
DS SWITCH DIMMER
3S 3 WAY SWITCH
RECESSED LENSED SHOWER LIGHT:
6" LENSED DOWNLIGHT
L
JS JAMB SWITCH
,J BOXS4" LENSED DOWNLIGHT
RECESSED LENSED LIGHT: LED L
2 scale 1/4"=1'-0"
LIVING LEVEL RCP - EXISTING 1 scale 1/4"=1'-0"
LIVING LEVEL RCP - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
DN
LOFT
XXX
T.O. GYPCRETE
136'-0"
T.O. STONE
135'-11"
OPEN TO BELOW
TOTAL
EXISTING
AREA:
377 SQ.
FT.
CL
O
S
E
T
1
A200
1
A201
2
A203
U
U
DSVOLUME
SP
S
R
DS
J
J
D
D
SS
6
U
DS S S
J
J
EF
D
FL
TV
SP
JS
DN
LOFT
500
T.O. GYPCRETE
136'-0"
T.O. STONE
135'-11"
OPEN TO
BELOW,
<16'H
1
A200
1
A202
1
A203
EXISTING WALL
NEW WALL
DEMOLISH
WALL TYPE KEY:
1
5011
500
LOFT BATH
501
3
12"
2'-
7
34"
31 2"5 1
2"
31
2
"
1'
-
6
"
CL
O
S
E
T
6'-6
"
8'-
6
34"
6'-
7
1 2"
7'-
7
5 8"
6'-5"
3'-4"
3'
-
4
"
3'-4"
6'-3
1
2"
TILE
WD.
W
D
.
W
D
.
2
A
3
0
0
EXISTING
SWITCH LEGS
AND WIRING
TO REMAIN.
VFY NEW
FIXTURES
W/ CLIENT.FL
DS
S S
J
EF
J
S
C
RCP/ELECTRICAL KEY:
SMOKE DETECTOR LOCATION
CARBON MONOXIDE DETECTOR
LOCATION; TO BE INSTALLED PER THE
STATE OF COLORADO REGULATIONS
(HARDWIRED)
S
CO
GENERAL ELECTRICAL NOTES:
1. TYPICAL COLOR OF OUTLETS,
SWITCHES, AND COVERS, VFY.
2. POWER AND LIGHTING DISTRIBUTION
TO FOLLOW REQUIREMENTS PER 2012
IRC
3. ELECTRICAL WALK-THRU IS REQUIRED
WITH ARCHITECT AT ROUGH-IN
4. VERIFY ALL FLOOR OUTLET LOCATIONS
WITH FINAL FURNITURE LAYOUTS
5. VERIFY HEIGHTS OF RECEPTACLES FOR
TVs WITH FINAL FURNITURE LAYOUTS.
6. VERIFY MANUF. POWER REQUIREMENTS
FOR ALL APPLIANCES.
7. PROVIDE LOCK BOXES FOR FIRE DEPT.
AT EACH UNIT
8. DEMOLITION ELECTRICAL DEPICTED IN
DRAWING WITH DASHED LINES. NEW
ELECTRICAL DEPICTED IN DRAWING
WITH SOLID LINES.
LIGHTING SYMBOLS
C
A
RECESSED LENSED SHOWER LIGHT: MR 16
4" DOWNLIGHT
RECESSED CAN LIGHT: MR 16
B L
4" LENSED DOWNLIGHT
D
UNDER-CABINET LIGHT
F
UCH
J-BOX / DECORATIVE PENDANT LIGHT
J
K
DECORATIVE WALL-MOUNTED SCONCE
LENSED WHERE NOTED; LED WHERE NOTED
LEDCOVE LIGHTING L
M LED PUCK-LIGHT
N CEILING MOUNT
K
I FLUORESCENT LIGHTING
EXTERIOR SCONCER
VANITY MIRROR W/ BUILT-IN LIGHTS
SPEAKERSP
BATHROOM EXHAUST FANEF
EXHAUST FAN/LIGHT COMBO
GROUND FAULT DUPLEX OUTLET @ +42" U.O.N.
U SMOKE DETECTOR
DUPLEX OUTLET, MNT. VERT. @ 18" AFF U.O.N.
GFI 220 OUTLET220
MOTION SWITCHMS
CENTERED IN BASEBD U.O.N.
QUAD. OUTLET, MNT. HORIZ.
CENTERED IN BASEBD U.O.N.
WALL MOUNTED TELEPHONE OUTLET
RECESSED FLOOR OUTLET
6 THERMOSTAT
TV 2 RG6 COAXIAL
LIGHTING CONTROLS KEYPAD LOCATIONKEY
LIGHTING CONTROLS CIRCUIT###
* DENOTES WIRELESS TABLETOP MODEL
E
G L RECESSED LENSED SHOWER LIGHT: MR16
4" LENSED DOWNLIGHT
CEILING FAN WIRING
LUTRON Q (OR SIM.) KEY PAD
LUTRON Q (OR SIM.) CIRCUIT DESIGNATIOND-
4" DOWNLIGHT
NEW RECESSED CAN LIGHT: LED
KEY
DUPLEX OUTLET, MNT. HORIZ. @ 46" AFF U.O.N.
VFY. W/ TILE LAYOUTSRECESSED CAN LIGHT: LIGHT 6"
O 4" ADJUSTABLE
RECESSED CAN LIGHT: LED ART LIGHT
TRACK LIGHTINGT
UPLIGHTU
W RECESSED WALL STEP-LIGHT *
12" A.F.F. - LED
*
*
Y*IN FLOOR LIGHT
*4" ADJUSTABLE
RECESSED CAN LIGHT: LED
S SWITCH
DS SWITCH DIMMER
3S 3 WAY SWITCH
RECESSED LENSED SHOWER LIGHT:
6" LENSED DOWNLIGHT
L
JS JAMB SWITCH
,J BOXS4" LENSED DOWNLIGHT
RECESSED LENSED LIGHT: LED L
2 scale 1/4"=1'-0"
LOFT LEVEL RCP - EXISTING 1 scale 1/4"=1'-0"
LOFT LEVEL RCP - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
TO SLAB
102'-0"
MASTER
116'-0"
LIVING
126'-0"
SPRING POINT
134'-8"
TO STONE CAP
147'-8"
JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE
TO MATCH EXISTING
NEW STEEL FRENCH BALCONY
TO MATCH EXISTING
M01 STONE TO MATCH EXISTING
M02 VERTICAL SIDING
M03
WINDOWS AND
DOORS
M05
M04
ROOF
M06 TO MATCH EXISTING GUTTER SYSTEM
M09
GUTTER
M10
RAILING
FINISHES KEY
FASCIA
M11
TO MATCH EXISTING
RAILING
M12
GARAGE DOOR
M13
TO MATCH EXISTING
M08
M07 SNOW FENCE L82.4 SNOW FENCE BY ROCKY MOUNTAIN SNOW GUARDS INC.
M14
TO MATCH EXISTING
M05
M02
M01
M01
M03
M08
MASTER
116'-0"
LIVING
126'-0"
SPRING POINT
134'-8"
TO SLAB
97'-8"
EXISTING STAIRWELL WALL
NEW MASTER FRENCH BALCONY
NEW
MASTER
SHOWER
WINDOW
NEW
DINING
SLIDER
EXISTING
BAY
WINDOW
EXISTING
BAY
WINDOW
NEW
DINING
WINDOW
NEW
ENTRY
WINDOW
NEW
JR. MASTER
DOOR
NEW
JR. MASTER
WINDOW
TOP OF DORMER
143'-11 3/8"
M05
M02
M01
M03
M08
M08
NEW
MASTER
WINDOW
NEW
MASTER
DOOR
NEW
MASTER
WINDOW
M08
NEW JR. MASTER DECK
EXISTING LIVING BALCONY
NEW LIVING ADDITION WALL
7.07" rise - 14 steps
5'
-
1
1
"
6'
-
1
1
15 16
"
EXISTING LANDING
111'-7 7/16"
NEW BEDROOM
106'-10 5/8"
11
5 8"
NEW ENTRY LANDING
104'-8 5/8"
(TO BE DEMOLISHED)
BOTTOM OF 1ST ENTRY STAIR
98'-9 5/8"
EXISTING RETAINING
WALL TO REMAIN
LOFT
136'-0"
2'
-
0
"
NEW
DINING
WINDOW
5'
-
4
3 16
"
12
NEW RAILING TO MATCH EXTG., NOT TO ALLOW
7+(3$66*(2)$63+(5(7<3
NEW STEEL TRELLIS
ELEVATIONS
A200
2 1/4" = 1'-0"
WEST ELEVATION - EXISTING
1 1/4" = 1'-0"
WEST ELEVATION - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
TO SLAB
99'-6"
BEDROOM
114'-0"
LIVING
124'-0"
LOFT
134'-0"
TO STONE CAP
147'-8"
MASTER
116'-0"
LIVING
126'-0"
SPRING POINT
134'-8"
TO STONE CAP
147'-8"
TO SLAB
102'-0"
JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE
TO MATCH EXISTING
NEW STEEL FRENCH BALCONY
TO MATCH EXISTING
M01 STONE TO MATCH EXISTING
M02 VERTICAL SIDING
M03
WINDOWS AND
DOORS
M05
M04
ROOF
M06 TO MATCH EXISTING GUTTER SYSTEM
M09
GUTTER
M10
RAILING
FINISHES KEY
FASCIA
M11
TO MATCH EXISTING
RAILING
M12
GARAGE DOOR
M13
TO MATCH EXISTING
M08
M07 SNOW FENCE TO MATCH EXISTING
M14
TO MATCH EXISTING
M01
M01
M01
M01
M02
M02
M01
M03
M03
M03
M04
M04
M05
M05
M08
M08
M10
M10
4'
-
5
716
"
EXISTING LANDING
111'-7 7/16"
ELEVATIONS
A201
1 1/4" = 1'-0"
WEST ELEVATION - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
TO SLAB
99'-6"
BEDROOM
114'-0"
LIVING
124'-0"
LOFT
134'-0"
TO STONE CAP
147'-8"
MASTER
116'-0"
LIVING
126'-0"
SPRING POINT
134'-8"
TO STONE CAP
147'-8"
TO SLAB
97-8"
JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE
TO MATCH EXISTING
NEW STEEL FRENCH BALCONY
TO MATCH EXISTING
M01 STONE TO MATCH EXISTING
M02 VERTICAL SIDING
M03
WINDOWS AND
DOORS
M05
M04
ROOF
M06 TO MATCH EXISTING GUTTER SYSTEM
M09
GUTTER
M10
RAILING
FINISHES KEY
FASCIA
M11
TO MATCH EXISTING
RAILING
M12
GARAGE DOOR
M13
TO MATCH EXISTING
M08
M07 SNOW FENCE TO MATCH EXISTING
M14
TO MATCH EXISTING
M01
M01
M01
M01
M02
M02
M01
M03
M03
M04
M04
M05
M05
M08
M08
M10
M10
NEW
JR. MASTER
WINDOW
NEW
JR. MASTER
DOORNEW
JR. MASTER
WINDOW
NEW
GUEST
WINDOW
NEW
MASTER
WINDOW NEW
MASTER
DOOR
NEW
MASTER
SHOWER
WINDOWEXISTINGBAY
WINDOW
EXISTINGBAY
WINDOW
NEWGUEST
WINDOW
NEW
DINING
WINDOW F.P. W/ GLASS
NEW
ENTRY
CORRIDOR
EXISTING
BAY
WINDOW
NEW
JR. MASTER
WINDOW
NEW
JR. MASTER
WINDOW
NEW
MASTER
WINDOW
EXISTING
LOFT
WINDOW
EXISTING
BAY
WINDOW
NEW
KITCHEN
WINDOW
EXISTING
LOFT
WINDOW
NEW
WINDOW
NEW
LIVING
DOOR
NEW
WINDOW
NEW
WINDOW
NEW BEDROOM
106'-10 5/8"
9
99
ELEVATION
A202
1 1/4" = 1'-0"
WEST ELEVATION - PROPOSED
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
147'-8"
MASTER
116'-0"
LIVING
126'-0"
SPRING POINT
134'-8"
TO STONE CAP
TO SLAB
102'-0"
LOFT
136'-0"
MASTER TO GYPCRETE
116'-0"
LIVING TO GYPCRETE
126'-0"
SPRING POINT
134'-8"
TO SLAB
97'-8"
NEW
LIFT AND SLIDE
POCKET DOOR
NEW BEDROOM
106'-10 5/8"
NEW
ENTRY DOOR
EXISTINGWINDOW
TO REMAIN
EXISTING
WINDOW
TO REMAIN
EXISTING
WINDOW
TO REMAIN
EXISTING
WINDOW
TO REMAIN
NEW
ADDITION
WALL
NEW
MASTER
ADDITION
NEW
BEDROOM
LEVEL
ADDITION
NEW
GARAGE
ADDITION
M02
OUTDOOR PATIO
M05
M03
JELDWIN WINDOWS AND DOORS, CHESTNUT BRONZE
M08
TO MATCH EXISTING
TO MATCH EXISTING
NEW IRON RAILING
M01 TO MATCH EXISTINGSTONE
VERTICAL SIDING
M03
M02
M05
WINDOWS AND
DOORSM04
ROOF
M06
M09
TO MATCH EXISTING GUTTER SYSTEM
M10
GUTTER
FINISHES KEY
RAILING
M11
M12
FASCIA
M07
GARAGE DOOR
TO MATCH EXISTING
RAILING
SNOW FENCE
M08
M13
TO MATCH EXISTING
TO MATCH EXISTING
M14
M04
TO MATCH EXISTING
M08
EXISTING STONE
WALL
NEW
JR. BED
DECK
NEW
MASTER
FRENCH
BALCONY
EXISTING
DINING/LIVING
BALCONY
M08
NEW ENTRY IRON HANDRAIL
7'
-
6
"
8'
-
1
15 16
"
28
'
-
1
"
5/8"
DRYWALL
CEILING
FINISH
34" PLYWOOD
912" LVL JOISTS
13/16" WARMBOARD-R
8'
-
3
3 8"
4'
-
3
15 16
"
1" FINISH FLOOR
1"
DRYWALL
CEILING
FINISH
34" PLYWOOD
16" BVC JOISTS
2" GYPCRETE
1" FINISH FLOOR
3'
-
4
"
EXISTING GARAGE
FLOOR
ELEVATION
6"
EXISTING MECHANICAL
ROOM ELEVATION
PROPOSED MECHANICAL
ROOM HEIGHT
PROPOSED HEIGHT
OF GARAGE LOWERING
TO SLAB
102'-6"
212" FLAGSTONE
34" PLYWOOD
712" LVL
1'
-
8
3 8"
NEW 7'6" TALL
GARAGE
DOOR
9'
-
2
58"
NEW
GARAGE
LEVEL
ADDITION
1'
-
4
5 8"
1'
-
0
11 16
"
EXISTING FLOOR ASSEMBLY TO REMAIN
EXISTING FLOOR ASSEMBLY TO REMAIN
NEW FLOOR ASSEMBLY
NEW SLAB
LOFT
136'-0"
ELEVATION
A203
1 1/4" = 1'-0"
SOUTHWEST ELEVATION - PROPOSED21/4" = 1'-0"
SOUTHWEST ELEVATION - EXISTING
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
FINISH ROOFING
COPPER FLASHING
6" HALF-ROUND
COPPER GUTTER
T&G SOFFIT TO
MATCH EXTG.
WOOD FASCIA
BLOWN-IN INSUL.
R-49 (MIN)
ROOF UNDERLAYMENT
/ WATERPR. MEMBR.
7
12
T.O.PLATE
2x6 EXT. WALL W/MIN.
R-21 BLOWN-IN OR
BATT INSUL
58" GYPSUM WALL BOARD
VFY O/HANG W/ EXTG
CLEAN 3/4" FREE DRAINING GRAVEL
GRAVEL THIS AREA REGARDLESS OF
WHETHER DRAIN IS LOCATED AT THIS
LOCATION
MIN. 1" X 1" BUILT-UP CANT OF
FLUID-APPLIED WATERPROOFING AT ALL
INSIDE CORNERS
FILTER FABRIC
CONC. SLAB RE:
STRUCT.
EXPANSION MATERIAL
CONC FTG RE: STRUCT.
DRAIN & DRY BD
5,*,'3(5)25$7('3,3(6/23('#
14" PER FOOT TO A DAYLIGHT OR A SUMP
LOCATION
CONC FDN WALL RE: STRUCT.
SEE STRUCT DWGS
T.O. FTG
2X FURRED WALL W/
BIBBS INSUL., TYP.
58" DRYWALL, TYP.
HOT-APPLIED, MONOLITHIC
WATERPROOFING MEMBRANE-- EXTEND
WATERPROOFING 36" ABOVE GRADE AND
TO BOTTOM OF FOOTING
WATER STOP, TYP.
COPPER FLASHING; SEAL LAPS
12" EXT. PLYWD. SHEATHING
6" STONE VENEER
BUILDING PAPER
DRAIN & DRY BOARD
SEALANT
LINE OF GRADE
METAL FLASHING W/ 3" VERT. LEG UP WALL FACE
LAPPED INTO WATERPROOFING MEMBRANE.
PROVIDE HEMMED OUTER EDGE AND LAP & SEAL
JOINTS
UNCURED NEOPRENE FLASHING--EXTEND 4" ABOVE
AND 4" BELOW VENEER LEDGER
12
"
ON
T
O
P
L
Y
W
D
.
12
"
L
A
P
3"
SHEET BITUTHANE
2' DRAIN AND DRY BOARD
HOT-APPLIED MONOLITHIC WATERPROOFING
MEMBRANE -- EXTEND WATERPROOFING 36" ABOVE
GRADE AND TO BOTTOM OF FOOTING
SHEET BITUTHANE; EXTEND MEMBRANE 12" MIN.
ONTO PRIMED SHEATHING
LIQUID FILLET OF LM3000 BY GRACE
HOT-APPLIED MONOLITHIC WATERPROOFING
MEMBRANE -- EXTEND WATERPROOFING 36" ABOVE
GRADE AND TO BOTTOM OF FOOTING
HOT-APPLIED MONOLITHIC WATERPROOFING
MEMBRANE -- EXTEND WATERPROOFING 12" ABOVE
LEDGER; LAP 8" OVER BITUTHANE
CONCRETE FOUNDATION WALL
LIGHTWEIGHT CONC.
W/ RADIANT HEAT
FINISH FLOOR
10MIL. VAPOR BARRIER
O/ R-10 MIN. RIGID
FOAM INSULATION
4" FREE DRAINING
GRAVEL, NO FINES
VAPOR BARRIER (WARM SIDE), TYP.
BUILDING PAPER
WOOD SIDING TO MATCH EXTG.
BLDG. PAPER
12" EXTERIOR PLYWOOD
1-18" PLYWD. SUBFLOOR
SANDSTONE PAVERS
MORTAR BED w/ SNOW-MELT
TUBING
DRAINAGE MAT
STONE VENEER
BUTYL TAPE LAP SEALANT
COPPER SCUPPER
(FULLY SOLDERED)
SEALANT
COPPER SCUPPER SLEEVE
6125 MEMBRANE W/ HYDROFLEX 30
EXTEND AH6125 INTO SCUPPER OPENING
UNDER HORIZONTAL PORTION OF
SCUPPER AND UP BOTH SIDES OF
SCUPPER OPENING, UNDER METAL
SCUPPER.
FELT PAPER; LAP 8" OVER
HOT-APPLIED W.P.
BITUTHENE LAPPED OVER
WPM 6125 AND BLDG. PAPER
CONTINUOUS 1" FILLET BEAD OF SEALANT AT
TRANSITION FROM HORIZ. TO VERT., TYP.
SLOPE TO DRAIN
18" ASPHALTIC PROTECTION BD
HEAT TRACE ALL SCUPPERS
12"
COPPER FLASHING
12"
1 2"
12"
3"
3"
3'
-
0
"
2x RS CEDAR FASCIA
STONE DECKING
2x RS CEDAR TOP
AND BOTTOM
RAILS
2x RS CEDAR
PICKETTS
6x6 RS CEDAR
NEWELLS
1 2"
FRONT SIDE
1 1-1/2"=1'-0"
TYP. WALL SECTION
2 1"=1'-0"
OVERFLOW SCUPPER DETAIL
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
3/4"=1'-0"
EXTERIOR RAILING DETAIL3
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
GLAZING REMARKSFRAME MAT'L.WINDOW
TYPE
TYPE / MANUF.
MASTER LEVEL
FRAME MAT'L.GLAZING REMARKSWINDOW
TYPE
NEW BEDROOM LEVEL
TYPE / MANUF.
W1
W2
W3
ALUMINUM
ALUMINUM
INTERIOR FRAME
MAT'L.
INTERIOR FRAME
MAT'L.
WINDOW R.O.
WINDOW R.O.WINDOW SIZE
WIDTH X HT.
WINDOW SIZE
WIDTH X HT.
VFY.
5'-0" x 4'-7 3/4"
DBL LOW-E
DBL LOW-E
DBL LOW-E
WOODJELD-WEN
JELD-WEN
2'-8" x 4'-5 5/8"
EXTERIOR FRAME
MAT'L.
GLAZING REMARKSWINDOW
TYPE
W17
WINDOW SCHEDULE -
WINDOW SYSTEMS
TYPE / MANUF.INTERIOR FRAME
MAT'L.
ALUMINUM POCKET LIFT AND SLIDE
WINDOW R.O.SYSTEM SIZE
WIDTH X HT.
VFY.13'-4" x 9'-0"DBL LOW-E; TEMPEREDWOODNANA
JELD-WEN ALUMINUM
T.O. GYPCRETE NEW BEDROOM
CASEMENT WINDOW
WOOD
WOOD
QUANTITY
QUANTITY
QUANTITY
2
1
2
2
W8
W9 ALUMINUM
4'-6 3/4" x VFY."
2'-5 1/4" x 8'-0"
DBL LOW-E
DBL LOW-EJELD-WEN
JELD-WEN ALUMINUM WOOD FRENCH CASEMENT - MATCH HEIGHT W EXISTING MASTER
BAY WINDOW HEIGHTS
WOOD FIXED
1
2
W10
W12
ALUMINUM DBL LOW-EJELD-WEN OUTSWING FRENCH DOOR 1WOOD6'-0" x 8'-0"
R.
O
.
R.O.
T.O. GYPCRETE MASTER
FRENCH DOOR
5'-0" x 5'-018"DBL LOW-E; TEMPEREDALUMINUMJELD-WEN WOOD 1
U-VALUE
.32
.32
.32
.32
.32
.32
.32
.32
GLAZING REMARKSFRAME MAT'L.WINDOW
TYPE
TYPE / MANUF.
LIVING LEVEL
INTERIOR FRAME
MAT'L.
WINDOW R.O.WINDOW SIZE
WIDTH X HT.
QUANTITY
W13
W14 ALUMINUM
VFY.3'-6 1/8" x 2'-0 7/8"
5'-6 5/8" x 3'-0"
DBL LOW-E
DBL LOW-EJELD-WEN
JELD-WEN ALUMINUM WOOD CLERESTORY WINDOW - FIXED
WOOD
FIXED
1
2
W15
W16
W21
ALUMINUM DBL LOW-EJELD-WEN 1WOOD14'-7" x 7'-10"
6'-9 12" x 7'-10"DBL LOW-E; TEMPEREDALUMINUMJELD-WEN WOOD
ALUMINUMJELD-WEN WOOD
1
15'-138" x 2'-10"DBL LOW-E FIXED
.32
.32
.32
.32
.32
GLAZING REMARKSFRAME MAT'L.WINDOW
TYPE
TYPE / MANUF.
LOFT LEVEL
INTERIOR FRAME
MAT'L.
WINDOW R.O.WINDOW SIZE
WIDTH X HT.
QUANTITY
W19
W20 ALUMINUM
8'-0" x 7'-358"DBL LOW-E
DBL LOW-EJELD-WEN
JELD-WEN ALUMINUM WOOD
WOOD
1
1
W18 ALUMINUM DBL LOW-EJELD-WEN 4WOOD3'-4" x 3'-0"
.32
.32
.32
NEW
GUEST
WINDOW
NEW
GUEST
WINDOW
2'-8"
4'
-
5
58"
3'-
0
"
VFY.
VFY.
NEW
JR. MASTER
WINDOW
3'-
0
"
4'
-
5
58"
2'-414"
R.
O
.
R.O.
2'-
1
0
"
4'-
7
34"
5'-0"
R.
O
.
R.O.
2'-4 1/4 " x 4'-5 5/8"
W6 ALUMINUM 6'-2 1/8" x 7'-5 3/4"DBL LOW-EJELD-WEN WOOD 1.32VFY.
6'-218"
7'
-
5
34"
R.
O
.
R.O.
FRENCH SLIDER
1'-
6
58"
5'-
6
34"
4'-1034"
R.O.
R.
O
.
VFY.
NEW
MASTER
WINDOW
FRENCH SLIDER
NEW
GUEST
WINDOW
NEW
MASTER
DOOR
2'-514"
8'-
0
"
R.
O
.
R.O.
6'-0"
8'-
0
"
R.
O
.
R.O.
VFY.
VFY.
2'
-
1
1
78"
5'-
0
18"
5'-0"
R.O.
R.
O
.
FRENCH CASEMENT
FRENCH CASEMENT
T.O. GYPCRETE LIVING
FIXED FRENCH CASEMENT
VFY.
NEW
KITCHENWINDOW
6'-
3
78"
2'
-
0
78"
3'-618"
R.O.
R.
O
.
NEW
DINING
SLIDER
7'-
1
0
"
4'-658"
R.O.
R.
O
.
VFY.
VFY.
NEW
DINING
WINDOW
1'-
0
"
7'-
0
"
2'-4"
R.O.
R.
O
.
NEW
LIVING
DOOR
6'-912"
7'-
1
0
"
R.
O
.
R.O.
VFY.
FIXED
4'-
2
58"
2'-
1
0
"
5'-138"
R.O.
R.
O
.
VFY.
T.O. GYPCRETE LOFT
FIXED
1'-
6
34"
612"
7'-
3
58"
8'-0"
R.O.
R.
O
.
1'-
6
34"
612"
7'-
3
58"
8'-0"
R.O.
R.
O
.
TRAPEZOID
TRAPEZOIDVFY.
VFY.8'-0" x 7'-358"
1'-
3
"
1'-
9
"
3'-4"
3'-
0
"
VFY.MULTI-UNIT ASSEMBLY
NEW
LIFT AND SLIDE
POCKET DOOR
FIXED
9'-
0
"
13'-4"
R.O.
R.
O
.
1 1/4"=1'-0"
WINDOW ELEVATIONS
3 NS
WINDOW SCHEDULE
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)
DOOR
NO.
INTERIOR DOOR SCHEDULE -- GARAGE LEVEL
ROOM
NO.
THICK-
NESS
MAT'LR.O.SIZETYPE
DOORROOM NAME
HANDING
REMARKS
MAT'L
PANELS
2100 2'-8" x 7'-0"D2
HINGE
TYPE*
HARDWARE
LEVER
TYPE*
LOCK
TYPE
DOOR
NO.
ROOM
NO.
THICK-
NESS
MAT'LR.O.SIZETYPE
DOORROOM NAME
HANDING
REMARKS
MAT'L
PANELS HINGE
TYPE*
HARDWARE
LEVER
TYPE*
LOCK
TYPE
INTERIOR DOOR SCHEDULE -- NEW BEDROOM LEVEL
LH
1101MECH. ROOM 2'-6" x 4'-2"D1 VFY.WOOD LH PASSAGE LADDER ACCES NEEDED FOR DOOR.
1103LAUNDRY D3 (2)2'-6" x 7'-0"DBL
1201G. CLOSET
D5
RH
1 RH
1
204 JR. W.C.
D5 LOCK-SET
1206GALLERY LH
17'-0 34" x 7'-6"
RH
LOCK
TYPE
DOOR
NO.
ROOM
NO.
THICK-
NESS
MAT'LR.O.SIZETYPE
DOORROOM NAME
HANDING
REMARKS
MAT'L
PANELS HINGE
TYPE*
HARDWARE
LEVER
TYPE*
INTERIOR DOOR SCHEDULE -- SHOWER DOORS
1
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
1-3/4"
SHOWER203A 1 N/ATEMP. GL.2'-0" x 7'-0"N/AN/A PIVOT EURO STYLE GLASS STEAM SHOWER DOOR; MA. HARDWARE TO BATH FIXTURESN/A
L1
L2
L3H3
L2
H1
H2
H2
PASSAGE
DOOR
NO.
EXTERIOR DOOR SCHEDULE
ROOM
NO.
TH
I
C
K
-
NE
S
S
MAT'L: INTERIOR / EXTERIORR.O.SIZETYPE
DOORROOM NAME REMARKS
100 GARAGE DOOR 1 XD1
HANDING
TRACK
HINGE OR TRACK & ASSOCIATED ACCESSORIES
TYPE
HARDWARE
HANDLE / LEVER TYPE LOCK TYPE
KEY PADWOOD
PANELS
3"
STILE @ RAIL OTHER
STOP STAY ROLLER &
GUIDE STRIP INTERIOR EXTERIOR PRIMARY
N/A N/A N/A
WOOD
PASSAGEL3H3WOOD
202 G. BEDROOM D4 WOOD L3H3 LOCK-SET
200 G. BATH 2'-0" x 7'-0"VFY.LH1-3/4"WOOD LOCK-SETL3H3
LHWOOD L3H3
RHWOOD L3H3
VFY.
WOOD
WOOD L3H3
1 D4
SPEC. TO BE VARIFIED
ELEVATOR VFY.WOOD PASSAGE
VFY.PASSAGE
1104STAIR D4 RH1-3/4"L2H2WOOD PASSAGE2'-6" x 7'-0"VFY.
3'-6" x 7'-0"206 ENTRY DOOR 1 XD2 LHWOOD2"VFY.DEAD-BOLT CUSTOM DESIGN TBD
1
D5 2'-0" x 7'-0"VFY.
VFY.
203 JR. BATH
2'-6" x 7'-0"
2'-0" x 7'-0"VFY.
D5 2'-0" x 7'-0"VFY.LOCK-SET
205 JR. MASTER BED VFY.2'-6" x 7'-0"LOCK-SET
2'-8" x 7'-0"D2 VFY.
DOOR
NO.
INTERIOR DOOR SCHEDULE -- MASTER LEVEL
ROOM
NO.
THICK-
NESS
MAT'LR.O.SIZETYPE
DOORROOM NAME
HANDING
REMARKS
MAT'L
PANELS
2302 2'-6" x 7'-0"D4
HINGE
TYPE*
HARDWARE
LEVER
TYPE*
LOCK
TYPE
LH
1301G. BEDROOM 4'-0" x 7'-0"D6 VFY.WOOD BARN LOCK-SET
1303MASTER BEDROOM D7 2'-912" x 7'-0"RH
1-3/4"
1-3/4"
1-3/4"L3
L3
L3
H4
H3
H3WOOD
CLOSET #2 VFY.WOOD PASSAGE
VFY.
1304MASTER BATH D4 PKT1-3/4"L2H5WOOD PASSAGE3'-312" x 7'-0"VFY.
LOCK-SET
1305MASTER W.C.D4 LH1-3/4"L3H3WOODVFY.
1306CLOSET D4 PKT1-3/4"L3H5WOOD PASSAGEVFY.
1307HALLWAY #3 LH1-3/4"L3H3WOOD PASSAGEVFY.
2'-6" x 7'-0"LOCK-SET
2'-6" x 7'-0"
2'-8" x 7'-0"D2
DOOR
NO.
INTERIOR DOOR SCHEDULE -- LIVING LEVEL
ROOM
NO.
THICK-
NESS
MAT'LR.O.SIZETYPE
DOORROOM NAME
HANDING
REMARKS
MAT'L
PANELS HINGE
TYPE*
HARDWARE
LEVER
TYPE*
LOCK
TYPE
1301HALLWAY #4 VFY.WOOD LH1-3/4"L3H3
DOOR
NO.
INTERIOR DOOR SCHEDULE -- LOFT LEVEL
ROOM
NO.
THICK-
NESS
MAT'LR.O.SIZETYPE
DOORROOM NAME
HANDING
REMARKS
MAT'L
PANELS HINGE
TYPE*
HARDWARE
LEVER
TYPE*
LOCK
TYPE
1501LOFT BATH 2'-0" x 7'-0"D5 VFY.WOOD RH LOCK-SET1-3/4"L3H3
2'-8" x 7'-0"D2 PASSAGE
1500LOFT 2'-0" x 7'-0"D5 VFY.WOOD LH PASSAGE1-3/4"L3H3
1 1/4"=1'-0"
DOOR ELEVATIONS2NS
DOOR SCHEDULE
PROJECT:
71
0
W
E
S
T
L
I
O
N
S
H
E
A
D
C
I
R
C
L
E
-
U
N
I
T
A
V
A
I
L
.
,
C
O
L
O
R
A
D
O
8
1
6
5
7
9
7
0
.
4
7
7
.
2
9
9
0
CR
O
S
S
R
E
S
I
D
E
N
C
E
12
6
F
O
R
E
S
T
R
D
.
VA
I
L
,
C
O
DRAWN BY:
DATE:
REVISIONS:
CROSS
-
12.06.13
Reviewed for Code Compliance
Code: 2012 International Building Code (IBC)