HomeMy WebLinkAboutB13-0553 Lighting Compliance COMcheck Software Vers�on 3.9.2
Interior Lighting Complianc�
Certificate
2012 IECC
Section 1: Project Information
Froject Type:Alteration
�roject Title:Bfu Cow Ti
Construction Site: OwnerlAgent: DesignerlContractor:
304 Bridge Street Lucas Edwards
#6C Architectural Engineering Associates
Vail,CO 40809 Hwy 6
5TE 2i4
Avon,CO 81620
(97D)748-6520
lucas@aec-vail.com
Section 2: Interior lighting and Power Calculation
A B C D
Area Category Floor Area A1lowed Allowed Watts
{ft2) W�tts!ft2 {B x C?
Common 5pace Types:8arlloungelleisure dining �020 1.4 3426
� Total A[lowed Watts= 9428
Section 3: Int�rior Lighting Fixture SchedUle
A B C p E
Fixture I�:Description 1 Lamp 1 Walfage Per Lamp 1 Sa�[ast Lampsl #of Fixture (C X D)
Fixture Fixkures Waft.
�Common Space Types:Barlloungelleisure dining(1020 sq,ft.)___ ;
,.��._______.�. � _,..__.._ _...._.... . ....�.. ____�__----� -- —---_ _ _____.._...
Linear Fluprescent 1:F1:48"T8 32W:E[ecfronic: 2 3 58 174
[ncandescent 1:Ai:Incandescent 50W: 1 2 50 100
Halogen'[:A2:Halogen MR-16 35W: 1 8 35 280
LED'[:Bi:Ofher: 1 10 1 10
Incandescent 2:Incandescent fiOW: 1 2 60 120
LED 2:Ci:4W 1 FT ROPE RIGHT:Other: 1 20 4 80
Incandescertt 3:�1:Incandescent 100W: 1 4 �00 400
Incandescent 4:D2:Incandescent 150W: 1 1 150 150
Track lighting'[:F1:GALLERIE ART HIGHLIGHTING:Wattage based on 46 feet of track 0 0 0 Exempt
Exemption:Dispfay Lighting in Gal]erieslMuseums
Total Proposed Watts= 1314
Sectfon 4: Requirements Checklist
Lighti�g Wattage:
� 1. Total proposed watts musf be less than vr equal to total allowed watts.
Aflowed Wattage:1428 Proposed Wat�age:93i4
Complies:YES
Mandatory Requirements:
�] 2. Dwelling units(compfete incfependent living facilities}within commercial buildings are not required lo comp[y with interior lighting
requirernents of this code provided that>=75 percenf oF fhe permanently inslalled fixiures other tha�Iow volfage lighting contain only
hign efficacy lamps.
0 3. Manual Contro]s:Each enclosed space has rr�anual lighting control.Remote[y located manual controls are Eabelled for area af service
and indicafe on/o�f status.
Project Tiile: Blu Cow Ti Report date: 12126l13
Data fifename: Unfitled.cck Page 1 of 3
Exception(s):
[] Securitylemergency areas with 24-ho�r operation.
❑ Stairwayslcorridors lf�aE are means of eg�ess.
� 4. Light Reduction Controls:Each space required to have a manual control also allows for reducing t�e connected lighting load by at least
5Q percent 6y either cantrolfing all luminaires,dual sw{tching of alternate rows of luminaires,alternate lumineires,or altemate lamps,
swifching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp.
Exceptron(s):
� Only one luminaire(famp a 100 W)in space.
[] An occupant-sensing device cantrols the area.
❑ The area is a corridor,equipmenflsiore rooms,resirooms,public lobby,eEec.lmech.room, or s[eeping unit.
� Areas that use<0.6 Wattslsq.iE.
❑ Daylight spaces having automalic day[ighfing controls.
� 5. Automatic time switching contro[s are installed and have an override switching device.The o�erride switching device allows for<=2
hour operation cycle within spaces<=500D sq.EE.,manual operafion,and is readily accessible and[ocated wh�re the operation of the
connected ligf�ts are�isib[e or communicated to the switch.
Excepfion(s):
0 Sleeping units,pafient care areas;and spaces where aulomafic shufolf would endangsr safely or security or where lighting is
intended for 24-hour operation.
[] Emergency egress[ighting.
� Spaces where lighting is controlled with occupancy sensors.
� Malls,arcades,auditoriums,single lenant retail spaces,industrial faciEiiies and arenas that are�=20,000 sq.ft.are perm[tted
exceed the 2-hour operation cycle[imit when a captive key device override switch is insfal[ed.
a 6. Occupant sensors are installed in the following spaces and automaii�ally lurn lighting off withi�30 minutes of alf occupants leaving the
space:Classrooms,conferencelmeeEingltraining rooms,employee lunch and breaEc rooms,private offices,storageljanitorial rooms,
resfrooms,and other spaces�=300 sq.ft.Automatic-on sensors set power on <5�percent power.
Exception(s):
� FuIE power automatic-on contro[s are permitted where manual-on operaEion would endanger the safety or security of the room or
6uilding occupants.
� 7. Daylight zones have either individual lighting controls independent from thaf of the general area lighi9ng that are either manual or
automatic and se�ve zones�=2,500 sq.ft.Zones under skylights more t�an 15 feet from the perimeEer have lighting controls separate
from daylight zones adjacent fo vertica]fenesEration.
Exception(s):
❑ Contiguous daylighf zones spanning no more fhan two orienfafions are allowed to 6e controlEed by a singEe controlling de�ice.
� Daylight spaces enclosed by wells or ceiling height partitions and containing two or fewer]ight fxtures are not required to have a
separate swifch for general area lighting.
� 8. Automatic daylight zone confrols are capable of reducing power fo<35 percenf using continuous dimming baflasts and
daylight-sensing controls OR,are capable of automatic power red�ction using step-dimming multi-level switching and daylight-sensing
controls having at least two controf channels per zone and at least one control step in the 54-70 percent range and another�=35
percenE of design pawer.
0 9. Medical Eask lighting or artlhistory display lighting claimed Eo be exempt from compliance has a control device independent of the
control of the nonexempt lighting.
� 10.Separafe co�trol devi�e(or displaylaccent lighling,case lighting,task Iighting,nonvisual lighfing,under-shelflcabinent lighling,lighling
for safe,and demonstraEion[ighting.
� 11. FEatellmotel sleeping unifs and guest suites have control device(s)at the entry door that control al[permanent luminaires and switched
recepYacles.
� 12, Exit signs 5 Watts or less per sign.
� 13.Tandem wired one-lamp and fhree-lamp ballasted luminaires(No single-lamp 6allasts).
Excepfion(s):
p Electronic high-frequency ballasts.
� L�minaires not on same switch.
❑ Recessed luminaires 10 R.apart or surFacelpendant not continuous.
� Luminaires on emergency circuits.
Section 5: Compliance Statement
Compliance Stafement: The proposed lighting alteration projecf represented in this document is consistenf wifh fhe b�ilding plans,
specifications and other ca[culations submitted with this permit application.The proposed lighting alteration project has been designed Eo meet
the 2012 IECC,Chapte�8,requirements in COMcheck Version 3.9.2 and to comply with the mandafory requirements in the Requirements
Checklist.
Project Title: Blu Caw Ti Report date: 12I2&113
Dafa filename: Untit[ed.ccEc Page 2 of 3
Lucas Edwards- Electrical Engineer 1212612D73
IVame-Title re Date
Project Title: 81u Cvw Ti Report dafe: 'E2I2fi113
Dafa fifename: [Jntilfed.cck Page 3 of 3