Loading...
HomeMy WebLinkAboutB13-0553 Lighting Compliance COMcheck Software Vers�on 3.9.2 Interior Lighting Complianc� Certificate 2012 IECC Section 1: Project Information Froject Type:Alteration �roject Title:Bfu Cow Ti Construction Site: OwnerlAgent: DesignerlContractor: 304 Bridge Street Lucas Edwards #6C Architectural Engineering Associates Vail,CO 40809 Hwy 6 5TE 2i4 Avon,CO 81620 (97D)748-6520 lucas@aec-vail.com Section 2: Interior lighting and Power Calculation A B C D Area Category Floor Area A1lowed Allowed Watts {ft2) W�tts!ft2 {B x C? Common 5pace Types:8arlloungelleisure dining �020 1.4 3426 � Total A[lowed Watts= 9428 Section 3: Int�rior Lighting Fixture SchedUle A B C p E Fixture I�:Description 1 Lamp 1 Walfage Per Lamp 1 Sa�[ast Lampsl #of Fixture (C X D) Fixture Fixkures Waft. �Common Space Types:Barlloungelleisure dining(1020 sq,ft.)___ ; ,.��._______.�. � _,..__.._ _...._.... . ....�.. ____�__----� -- —---_ _ _____.._... Linear Fluprescent 1:F1:48"T8 32W:E[ecfronic: 2 3 58 174 [ncandescent 1:Ai:Incandescent 50W: 1 2 50 100 Halogen'[:A2:Halogen MR-16 35W: 1 8 35 280 LED'[:Bi:Ofher: 1 10 1 10 Incandescent 2:Incandescent fiOW: 1 2 60 120 LED 2:Ci:4W 1 FT ROPE RIGHT:Other: 1 20 4 80 Incandescertt 3:�1:Incandescent 100W: 1 4 �00 400 Incandescent 4:D2:Incandescent 150W: 1 1 150 150 Track lighting'[:F1:GALLERIE ART HIGHLIGHTING:Wattage based on 46 feet of track 0 0 0 Exempt Exemption:Dispfay Lighting in Gal]erieslMuseums Total Proposed Watts= 1314 Sectfon 4: Requirements Checklist Lighti�g Wattage: � 1. Total proposed watts musf be less than vr equal to total allowed watts. Aflowed Wattage:1428 Proposed Wat�age:93i4 Complies:YES Mandatory Requirements: �] 2. Dwelling units(compfete incfependent living facilities}within commercial buildings are not required lo comp[y with interior lighting requirernents of this code provided that>=75 percenf oF fhe permanently inslalled fixiures other tha�Iow volfage lighting contain only hign efficacy lamps. 0 3. Manual Contro]s:Each enclosed space has rr�anual lighting control.Remote[y located manual controls are Eabelled for area af service and indicafe on/o�f status. Project Tiile: Blu Cow Ti Report date: 12126l13 Data fifename: Unfitled.cck Page 1 of 3 Exception(s): [] Securitylemergency areas with 24-ho�r operation. ❑ Stairwayslcorridors lf�aE are means of eg�ess. � 4. Light Reduction Controls:Each space required to have a manual control also allows for reducing t�e connected lighting load by at least 5Q percent 6y either cantrolfing all luminaires,dual sw{tching of alternate rows of luminaires,alternate lumineires,or altemate lamps, swifching the middle lamp luminaires independently of other lamps,or switching each luminaire or each lamp. Exceptron(s): � Only one luminaire(famp a 100 W)in space. [] An occupant-sensing device cantrols the area. ❑ The area is a corridor,equipmenflsiore rooms,resirooms,public lobby,eEec.lmech.room, or s[eeping unit. � Areas that use<0.6 Wattslsq.iE. ❑ Daylight spaces having automalic day[ighfing controls. � 5. Automatic time switching contro[s are installed and have an override switching device.The o�erride switching device allows for<=2 hour operation cycle within spaces<=500D sq.EE.,manual operafion,and is readily accessible and[ocated wh�re the operation of the connected ligf�ts are�isib[e or communicated to the switch. Excepfion(s): 0 Sleeping units,pafient care areas;and spaces where aulomafic shufolf would endangsr safely or security or where lighting is intended for 24-hour operation. [] Emergency egress[ighting. � Spaces where lighting is controlled with occupancy sensors. � Malls,arcades,auditoriums,single lenant retail spaces,industrial faciEiiies and arenas that are�=20,000 sq.ft.are perm[tted exceed the 2-hour operation cycle[imit when a captive key device override switch is insfal[ed. a 6. Occupant sensors are installed in the following spaces and automaii�ally lurn lighting off withi�30 minutes of alf occupants leaving the space:Classrooms,conferencelmeeEingltraining rooms,employee lunch and breaEc rooms,private offices,storageljanitorial rooms, resfrooms,and other spaces�=300 sq.ft.Automatic-on sensors set power on <5�percent power. Exception(s): � FuIE power automatic-on contro[s are permitted where manual-on operaEion would endanger the safety or security of the room or 6uilding occupants. � 7. Daylight zones have either individual lighting controls independent from thaf of the general area lighi9ng that are either manual or automatic and se�ve zones�=2,500 sq.ft.Zones under skylights more t�an 15 feet from the perimeEer have lighting controls separate from daylight zones adjacent fo vertica]fenesEration. Exception(s): ❑ Contiguous daylighf zones spanning no more fhan two orienfafions are allowed to 6e controlEed by a singEe controlling de�ice. � Daylight spaces enclosed by wells or ceiling height partitions and containing two or fewer]ight fxtures are not required to have a separate swifch for general area lighting. � 8. Automatic daylight zone confrols are capable of reducing power fo<35 percenf using continuous dimming baflasts and daylight-sensing controls OR,are capable of automatic power red�ction using step-dimming multi-level switching and daylight-sensing controls having at least two controf channels per zone and at least one control step in the 54-70 percent range and another�=35 percenE of design pawer. 0 9. Medical Eask lighting or artlhistory display lighting claimed Eo be exempt from compliance has a control device independent of the control of the nonexempt lighting. � 10.Separafe co�trol devi�e(or displaylaccent lighling,case lighting,task Iighting,nonvisual lighfing,under-shelflcabinent lighling,lighling for safe,and demonstraEion[ighting. � 11. FEatellmotel sleeping unifs and guest suites have control device(s)at the entry door that control al[permanent luminaires and switched recepYacles. � 12, Exit signs 5 Watts or less per sign. � 13.Tandem wired one-lamp and fhree-lamp ballasted luminaires(No single-lamp 6allasts). Excepfion(s): p Electronic high-frequency ballasts. � L�minaires not on same switch. ❑ Recessed luminaires 10 R.apart or surFacelpendant not continuous. � Luminaires on emergency circuits. Section 5: Compliance Statement Compliance Stafement: The proposed lighting alteration projecf represented in this document is consistenf wifh fhe b�ilding plans, specifications and other ca[culations submitted with this permit application.The proposed lighting alteration project has been designed Eo meet the 2012 IECC,Chapte�8,requirements in COMcheck Version 3.9.2 and to comply with the mandafory requirements in the Requirements Checklist. Project Title: Blu Caw Ti Report date: 12I2&113 Dafa filename: Untit[ed.ccEc Page 2 of 3 Lucas Edwards- Electrical Engineer 1212612D73 IVame-Title re Date Project Title: 81u Cvw Ti Report dafe: 'E2I2fi113 Dafa fifename: [Jntilfed.cck Page 3 of 3