HomeMy WebLinkAboutB14-0006 08-11-2014 Inspection Request Reporting Page 5
4:08 pm -- Vail, CO - City Of Reporting k'4 0o lg
Requested Inspect Date: Tuesday August 12,2014
Site Address: 75 S FRONTAGE RD W VAIL
Police Department Training and Briefing
A/P/D Information
Activity B14-0006 Type: COMBO Sub Type: ACOM Status: ISSUED
Const Type Occupancy: Use: B Insp Area:
Owner VAIL COLORADO MUNICIPAL BLDG
AUTHORITY
Contractor: TOWN OF VAIL Phone: 970-479-2170
Description: Install 10 new floor receptacle and 5 surface mounts.Add 5 new circuits from panel L-6 to new outlets through
garage to electrical room. Pipe a 3/4"conduit to floor boxes for communication from IT room on main floor in
Police briefing and training room.
Comment: Corrections Received. Routed to D3-Value revised to$15000 electrical-SBELLM
Comment: paper submittal scanned to laserfiche and routed to D-3-CGODFREY
Requested Inspection(s)
Item. 90 BLDG-Final Requested Time: 09:00 AM
Requestor TOWN OF VAIL Phone: 970-479-2170
Comments 9-1•43
Assigned To v,"la RAGON Entered By: JMONDRAGON K
Action '0
CA Time Exp:
Item •0 ELEC-Final Requested Time: 04:30 PM
Requestor ,P W N OF VAIL Phone: 970-479-2170
Comments 389-16;3
Assigned To. S 1 f ER Entered By: JMONDRAGON K
All I A Time Exp:
i '
1
Inspection History P
I V(
Item 120 ELEC-Rough ei
Item 130 ELEC-Conduit
Item 190 ELEC-Final
Item 90 BLDG-Final
REPT131 Run Id: 14851
NOTE: TH/S PERMIT MUST BE POSTED ON JOBS/TE AT ALL T/MES
. ,.
7C}WNOF VA�I„''
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B14-0006
Project #: PRJ14-0018
Job Address: 75 S FRONTAGE RD W VAIL Applied.....: 01/24/2014
Location......: Police Department Training and Briefing Issued. . . : 06/18/2014
Parcel No....: 210106400003
OWNER VAIL COLORADO MUNICIPAL BLDG 01/24/2014
75 S FRONTAGE RD
VAIL, CO
81657
CONTRACTOR TOWN OF VAIL 01/24/2014 Phone: 970-479-2170
JOHN KING
75 SOUTH FRONTAGE ROAD
� VAIL
CO 81657 :��::
License: C000003502
Description:
Install 10 new floor receptacle and 5 surface mounts. Add 5
new circuits from panel L-6 to new outlets through garage
to electrical room. Pipe a 3/4"conduit to floor boxes for
communication from IT room on main floor in Police briefing
and training room.
Occupancy: B Type Construction: Valuation: $15,000.00
......................................................�..«....,,,..,_............. FEE SUMMARY .,,x.........,...>,.........................,,...,,.....,.,..,.......».......,,,,,..
Building Permit-----------> $251.25 Bldg Plan Check----------> $163.31 Use Tax Fee-----------------------> $100.00
Electrical Permit---------> $546.25 Elec Plan Check-----------> $355.06 Restuarant Plan Review-------->
$0.00
Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees-------------------->
Plumbing Permit--------> $0.00 Plmb Plan Check---------> ($874.62)
$0.00 Recreation Fee--------------------> $0.00
Investigation-----------------------> $0.00
Will Call------------------------------> $5.00
� TOTAL PERMIT FEES--------------> $546.25
Payments-------------------------------> $546.25
BALANCE DUE------------------------> $0.00
,...,,...,........................,,..,..,....,..__,........x...............,.,...«...»..,....,,............,.............,............,..,.,.,........,.........................,......
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM -4:00 PM.
combination permit_012811
�
. �
��V��� i
''A�t?
•x•x.x+�x xw,r.rr,rr..,r.vrvr..�,r��xx���xx�....es+w w w...x•xx,r+,r,r,r����x..•x•+•xwvrwe++v�a•,.,rwwv.v.+v.���+�aws,xxr:..e.w+•w..ww��:�r.xxx�,rf+r.xa w+.+x.�.r,r,rvrr.xx+.+•r+••.w,r.rw+,.vr,.w,r�e+t++rtrwv.��s.�*f�s.xr��t
;'�
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
�
Permit#: 614-0006 Address: 75 S FRONTAGE RD W VAIL
Owner: VAIL COLORADO MUNICIPAL BLDG AUTHORITY Location: Police
Department Training and Briefing
...........................................................................................»,,..........................,....,..,........,..,,,...,,...,....,..,.,...................
. ,�
;-
�;:;
�,>.
combination permit_012811
.
#
�
iV�"�I11 V� Ti.1AJJ �
*,t*,r**,r r*****,t**,r,r**,r******t***,t*,r,r**,r,t*w w*r w w w,r,r r*r,t******t t*,r w w,r,r,r r,t,t***,t,t*****,r,r,r r r r,t**r*+r**,t,t***r,r*�t*x*,r,t*tr*tr*t t***r r w,r,r*,r,r r r r r w r,t*r r***+r****,t*,r
REQUIRED INSPECTIONS AND STATUSES
�
Permit#: B14-0006 Address: 75 S FRONTAGE RD W VAIL
Owner: VAIL COLORADO MUNICIPAL BLDG AUTHORITY Location:
Police Department Training and Briefing
***«*„«..*.*�**.*****«*«**.***«*******.**.*.,,,,*,,,,*,,.,.,,,******,,,,****„*�*««**,,,,*.,�***„***.,********,«*««**************.*.,,.***�***.,*****««**.,**�*********
Item: 00120 ELEC-Rough
Item: 00130 ELEC-Conduit
Item: 00190 ELEC-Final
Item: 00090 BLDG-Final
.�,.,.
� �i,
combination permit_012811
1
*****+********�*****+*+***+**************************�***********************+**************
TOWN OF VAIL, COLORADO Statement
***************++*************+*+*****++*********+*+****************************************
Statement Number: R140000837 Amount: $546.25 06/18/201402:59 PM
Payment Method:Credit Crd Init: CG
Notation: mc adam
johnson
-----------------------------------------------------------------------------
Permit No: B14-0006 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-064-0000-3
Site Address: 75 S FRONTAGE RD W VAIL
Location: Police Department Training and Briefing
Total Fees: $546.25
This Payment: $546.25 Total ALL Pmts: $546.25
Balance: $0.00
***************************+*************************�***********+**************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
EP 00100003111100 ELECTRICAL PERMIT FEES 546.25
-----------------------------------------------------------------------------
'
Department of Community Development
75 South Frontage Road
TQWN OF VAIL� va�i, co s�ss7
Tel: 970-479-2128
www.vailgov.com
sm(�� Development Review Coordinator
BU ING PERMIT APPLICATION /�
eparate applications are required for alarm & sprinkler) CK.�- •
Project Street Address: Project#: � ` '
a�7r _ vT lf�5e
(Number) (Street) (Suite#) DRB#:
Building/Complex Name: �c� l �
Building Permit#: �1 �`�O c.�..� ,
Contractor Information �� �� /�'� Lot#: Block# Subdivision:
� Business Name: �v,c/ �c- ��/.�-r�
Business Address: 7f��,+1 ��v,�o �Q Work Class: New( ) Addition( ) Alteration (��
C�tY l//¢"-� State: � Zip: 8!(oS7 TYPe of Building:
Single-Family( ) Duplex( ) Multi-Family( )
Contact Name: D����.cC
Commercial (�Other( )
Contact Phone:_ 9 r� - �7�'7'-�/7�
Contact E-Mail: J/lz',ad �s `,,¢�,G��, � Work Type: Interior(� Exterior O Both O
_
_ . . _
I hereby acknowledge that I have read this application,filled out Valuation of
in full the information required,completed an accurate plot plan, Work Included Plans Included Work
and state that all the information as required is co�rect. I agree to ---- - - - - -- - -� , -- _
Electrical � � ( � Yes �(V )No
comply with the information and plot plan, to comply with all Town ( es ONo /.SOl,►�.``fi`
ordinances and state laws, and to build this structure according to Mechanical ( )Yes ( )No ( )Yes ( )No
the town's zoning and subdivision codes, design review ap-
proved, Intemational Building and Residential Codes and other Plumbing ( )Yes ( )No ( )Yes ( )No
ordinances of the plica to.
Building ( )Yes ( )No ( )Yes ( )No
X ��- Value of all work being perFormed: $
Own�r/Owner's Repre tative Signature(Required) ;(value based on IBC Section 109.3&IRC Section 108.3�
Electrical Square Footage
... �._.._.._ ..,.__. .. ._ .,,. .. __.,._.. ..� .._ �. _.....__ .. _.. .'
Applicant Information , Detailed Scope and Location of Work: 1,vsTl�t� /�/�/�J
Applicant Name: � �pc-F,�.1C6�J �LG}�� �QP��l7�GL1�' L�icP� �.t//� SU,eFiS�
Applicant Phone: �i� ' ���'1 ^((v�`� �'IDi.�J�9 pdZBle Oi�i�Y .PP/� T7��G.et'
Applicant E-Mail: /-�'�'OT-M>SO�tI� U,f��.� C�� �e� �T s ��L�� l�lm�� ,� �,ZsT,�
Project Infortnatiory /� e,/ ��J�'���� ��Gay��jo� ��i �
Owner Name: �//�T-y (�� �v/���p �D6 � �
�T�i_��s .¢�� �/�3,� 7,4./l
Parcel#: �101'D�i Y DrD' 3
(For Parcel#,contact Eagle County Assessors Office at(970-328-8640 or visit
www.eaglecou nty.uslpatle)
(use additional sheet'rf necessary)
For Omce Use Only: � � � � � �
Fee Paid: Date Received:
Received From: D
c�5n Check# JUN 12 2014
CC: Visa/ MC Last 4 CC# exp date:
Auth # •
TOWN OF VAIL �
2013-Feb Ol
_.
:;,
Entries for Item:5100 - BUILDING DEPARTMENT 09:56 06/13/2014
Action Comments B Date
CR ELECTRICAL ENGINEER STAMPED JRM 02/04/2014
PLANS REQUIRED.
Total Rows: 1
Page 1
PANEL EM-1
PROJECT: VAIL POLICE STATION ENGINEER: SOH
PROJECT#: 14020 VOLTAGE: 120/208V, 3P,4W
MOUNTING: SURFACE MAINS: 400A MLO
TYPE: EXISTING AIC: 10K
PHASE PHASE
DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION
COMMAND CENTER REC 5 900 20 1 1 2 3 0 SURGE PROTECTOR
COMMAND CENTER REC 5 900 20 1 3 4 0 "
COMMAND CENTER REC(5) 900 20 1 5 6 � "
COMMAND CENTER REC 5 900 20 1 7 8 3 0 ECP-UPS
COMMAND CENTER REC 5 900 20 1 9 10 0 "
COMMAND CENTER REC(5) 900 20 1 11 12 0
UPSTAIRS COMPUTER ROO 0 2 13 14 4 0 ELEVATOR
0 15 16 0
30 AMP PHONE BOARD REC 0 1 17 18 0
PANEL EM-2 0 150 3 19 20 0
0 21 22 3 100 0 PANEL L-5B
0 23 24 0
0 25 26 0
0 27 28 1 20 0 PHONE ROOM LIGHTS
�' 0 29 30 1 20 0 PHONE BOARD
PANEL L-1 0 150 3 31 32 3 100 0 PANEL L-4
0 33 34 0
0 35 36 0
0 37 38 3 100 0 PANEL L-2
0 39 40 0 "
0 41 42 0
LOAD CALCULATION SUMMARY HIGHEST DEMAND DETERMINED BY METERING FROM 5/5/14 TO 6/5/14.
NEW LOADS ARE ADDED AT CIRCUITS 1,3,5,7,9,11,
CALCULATED POWER FACTOR: REST OF THE LOADS ARE INCLUDED IN HIGHEST DEMAND
1.00 DIESEL GENERATOR NAMEPLATE IS 169 KVA
CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS
HIGHEST DEMAND 93000 258 116250 322 � � `
LIGHTING/CONTINUOUS 0 0 0 0 ;�, ""; � � ,
RECEPTACLES 5400 15 5400 15 --
MECHANICAL 0 0 0 0 '
KITCHEN 0 0 0 0
TOTAL 98400 273 121650 337 - "'
� � � �
6/6/2014
.
�tG4 Multi-Servioe Pok�Thru Device� by Legrand Page 1 of 4
t�k�g�ran��
designed to be better.
_ _ __.
�:Search
RC4 Multi-Service Poke-Thru Device
RC4
The Walke�RC4 Series is a flush poke-thru device ideal for providing audioNideo services lo the woAcstation in an open space,above-grade floor environment.It accepts up to our
ports of connectivily devices to provide a seamiess and aesthedcally pleasing interface for voice,data,and fiber oplic applicatlons at the point of use.All Walker flush poke-thru
devices come with built-in TopGuerd^"Drotedion,an industry-leading design that meets and exceeds UL scrub water exclusion requirements for tile and carpet floors.All Walker flush
poke-thru devices can be installed on tile,carpet,or wood floors•
Submit QuerY
Where to buy . �: . .. Submit c2uery �
I
i
Li�..; �. Tweet �' . . �.._....
x�
�y��
4�<'
��.�.
.. � � � � � � O V �
D
JAN 2 � 2014
�
. TOW�f OF VAIL
�
� u
• _1
htt ://www.legrand.us/wiremold/poke-thru-devioeslsurfaoe-pok�thru-deviceslmulti-servic... 1/22/2014
P
� . � �� ...�.
� RC4 Multi-Service Pok�Thru Devioe� by Legrand Page2 of 4
product gallery
Representative images shown.
AVAILABLE OPTIONS
�
�
�
,�
• SPECIFICATIONS
• RESOURCES
• COMPONENTS
features 8�benefits
• An iMegral design which kesps out water,diR,and delxis from the power and communication compartments.Whenever you see the TopGuard protection icon applied
to any Wiremold product,you will know that the produd meets and excseds the new UL scrub water exGusion requirement.
• Power receptacles wired fw two circuib.Four 20A power receptaGes are wired with a 6wire system with individual neutral and ground wires.The 20A receptaGes can be
wired as standard receplaGes or for isolated ground.The receptaGes are UL Listed to U.S.and Canadian safely standards.
• UL Listed and UL Fire Classifled to U.S.and Canadian safety standards fw tlle,terrouo,and the future UL requirements under UL514A and UL514C for the scrub
water exelusfon test tor carpet and wood floon.This future requirement takes eftect June,2003.
• New brushed aluminum flange option.Provides additional color op6ons for better aesthetics.
• Communication connectors can be mounted both flush and recessed.Flexibility to maunt fiber optic,coaxial,video,and audio connectors below the finished floor surface
tor protectlon when not in use.Onty flush poke-thru device in Me industry that s�ppoRS fiber optic connectors and quad power.
• "Stepon-iC'installatlon.Allows quick and simple installation wilhout additional fasteners.Labor savings provided by eliminating the need for a second installer.All wiring can
be completed at floor level.
• Individual slide covers and"Dead-iront"protection.Slide covers protect power and communication devices.Power slide covers snap back in place when pawer receptacles
are not in use to ptevent water,diA,and debris from entering device.Flexibility to ac[ivate either power w communication services simultaneousy or individually.
• Suitable for uae in air handling spaces in aeco►danee with Sec 300-22(C)of the National ElecVical Code.
• Datacom connecUvity options.Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthedcally pleasing
interface for voice,data,audio,and video applica6ons at the point-of-use.A wide selection of data and bezel opGons available for use with Ortronics�,TracJack�,and
Series II devices.
• Meets ADA Aceessibility Guidelines.Even though ADA does not specifically cover floor boxes or pdce-thru devices,the wide Vim flange on the produd is designed to meet
lhe ADA Accessibility Guidelines as it peRains to ADA Sta�dard 4.5 which addresses changes in ground and floor surface levels.The poke-thru trim flanges are beveled so the
.;
slope is no grealer than a 1:2 reGo.
Top 5 Resources
RC4 Series Poke-Thru Devices(Installation Instructio�s)
RC4 Series MuIU-Service Poke-Thru Device Abandonment Fittings-ABPLUG3,ABPLUG4(Installation InsVUCtions)
RC4 Series Replacement Scrub Water Kit pnstallaGon Instructions)
RC4 Series Multl-Service Poke-Thru Device Adapters-COM50,COM75(Installafion Instrudions)
RC3,RC4&RC7 Series MuW-Service Poke-Thru Device Replacement ReceptaGe-RC37REC,RC4REC2,RC37REC-25,RC4REC2-25(Installation Instructions)
> specifications
x Generallnfo
• Product Series:RC4
• Type:Multi-Service
• Component Type:Full Assemblies
" Dimensions
• Hole Size:4"
,,� . . ..... -- 1 -:,.,.< „�; a g�, ,�,r�F+,,,,.,, .
�. ec � . .. � .
� . � Y � d '� ��� ��d ��� � � � .
, � � rd}���°d � ��.� �� t� €� �'3" .
.�;,ra a�rt#�';.. .. ... � . .. . .�3»' . ����;�`���3 ; . ..
Buy American Act Compliance
• Country of Origin:MEXICO
• Buy American Ad Status:Trade P�greement Ad Compliant
�
: �,��
d. �:� .
,a�
resources
http://www.legrand.us/wi remold/pok�thru-devioeslsurfaoe�poke�thru-devioes/multi-servic... 1/22/2014
. .._. �WdPdW ++a?4ir:-:.%
' RC4 Multi-Servioe Pok�Thru Devioe� by Legrand Page 3 of 4
BROCHURE
Poke-ThruPDF(8mb)
Wiremold Open Space BrochurePDF(1.21mb)
CUTSHEET
Flush Style Poke-Thru Devices PDF(2.1mb)
Chicago Approved Poke-Thru DevicesPDF(953.12kb)
CAD DRAWINGS
• RC7 Series Communication Adapter-COM50DXF(90.56kb)
�RC4 Series Abandonment Plate-RC4APTCDXF(147.28kb)
• RC4 Series Assembled Poke-Thru Device-RC4A(RT)TCDXF(1.68mb)
• RC4 Series Poke-Thru Device-RC4ARTTC-WBDXF(1.46mb)
�Suriace Style Poke-Thru-RC4ATCDXF(1.68mb)
� RC4 Series Surface Syle Poke-Thru-RC4ATC(LJB)DXF(1.47mb)
• RC4 Series Finish Flange 8 Slide Holder Assembly-RC4CRTTCDXF(1.03mb)
� RC4 Series Poke-Thru Device Finish Flange&Slide Hdder Assemby-RC4CTCDXF(1.03mb)
• RC4 Series Poke-Thru Device ReVOfit Kit-RC4KTCDXF(1.16mb)
• RC4 Series Poke-Thru Devic Slide Holder-RC4SHTCDXF(985.62kb)
• RC4 Series Recessed Floor Box-RC4SRTTCDXF(948.41 kb)
� RC4 Series Insert Assembly with Disposable Plate-RC4STCDXF(948.41 kb)
INSTALLATION INSTRUCTIONS
RC4 Series Poke-Thru DevicesPDF(773.22kb)
RC4 Series Mu16-Service Poke-Thru Device Abandonment Fittings-ABPLUG3,ABPLUG4PDF(262.94kb)
RC4 Series Replacement Scrub Water KitPDF(554.16kb)
RC4 Series Mutti-Service Poke-Thru Device Adapters-COM50,COM75PDF(114.13kb)
RC3,RC4&RC7 Series Multi-Service Poke-Thru Device Replacement Receptacle-RC37REC,RC4REC2,RC37REC-25,RC4REC2-25PDF(1010.83kb)
BIM MODELS
RC4 SeriesZlP(3.83mb)
GUIDE FORM SPECIFICATIONS
Flush Poke-Thru DeWces-RC7,RC9,RC9AMD,RC3,RC4,AMDB,AV3DOC(131.5kb)
Flush Poke-Thru Devices-RC7,RC9,RC9AMD,RC3,RC4,AMDB,AV300C(131.5kb)
SUPPORTING DOCUMENT
cULus Fire ClassificationPDF(173.69kb)
RC4 Series Part Lisl-COOXLS(96kb)
ULC Fire Classfica6onPDF(162.97kb)
ONLINE RESOURCES
' NAremold Spec Wfzard-16130
�
components
�,
RC4CTCBK,RC4CTCGY,RC4CTCW,RC4CTCAL,RC4CTCBS,RC4CTCAB,RC4CTCAA
RC4 Multi-Service Poke-Thru Finish Flanpe 6 Slide Holder Assembly
�
�
RC4SHTCBK,RC4SHTCGY,RC4SHTCW,RC4SHTCBS,RC4SHTCAI.
RC4 Multl-Service Poke-Thru Device Slide Holder Assemby
:_ .
�
RC4APTCBK,RC4APTCGY,RC4APTCW,RC4APTCBS
RC4 Multi-Service Assembled Poke-Thru Device AbandonmeM Plate
�:l
�;�,�s
COM75
RC7 Multi-Service Assembled Poke-Thru Device Communica6on Adapter
�
RC4KTCBK,RC4KTCGY,RC4KTCW,RC4KTCAL,RC4KTCBS
RC4 Multi-Service Assembled Poke-Thru Device Retr�t Kit
http://www.legrand.uslwi remold/pok�thru-devioeslsurface-pok�thru-devioes/multi-se�vic... 1l22/2014
.�
�
_ __ ��_.�.F,�.�.�.t.� �����
- ' RC4 Multi-Service Pok�Thru Devioe� by Legrand Page4 of 4
�
RC4REC2
RC4 Multi-Service Assembled Poke-Thru Device Replacement Receptacle
��
RC4REC2-25
RC4 Multi-Service Assembled Poke-Thru Device Replacement ReceptaGe
�
ABPLUG4
AMDB CommunicaGons Poke-Thru Device Aba�donment Plup Assembly
4
;.
http://www.legrand.uslwi ranold/poke�thru-devioeslsurfao�poke-thru-devioes/multi-servi c... 1/2?J2014
;_ ��. ._�
:'€
Adam Johnson
From: Stanton O Humphries <stan@aec-vail.com>
Sent: Friday,June 06, 201411:29 AM
To: Adam Johnson
:', Subject: RE: Complete month of Vail PD/Muni panel load
� Attachments: TOV POLICE DEPARTMENT PANEL EM-l.pdf
Hi Adart�.
�
Here's our panel schec�ule ft�r EM-l. Ttae t�ig��est derr�ar�c1 frc�r�� tt��c�er��ar�d recc�rc��r( I�ave taken fror�� c�(ur���� D�. �?c}��r
810,93 kva ar 258 arnps. Per NEC we adc� 25%or� tt�tt7at and wouici have a hi�t�est c�err7and of 322 ar��ps. Acic� 3C
rece�tacles tlirough f circuits arid we�;et a derr�aric� a�r�ps caf 337 nr� tl7e�iClO arnp �ariel. Sor��e spar�capac€ty r�c��
much. 1t is gt�r�d to be on solid groun�.
Kir�dly review ar�t� see if I've gat it ail correct. Please call with ariy disci�ssion or hit reply with cc�rn�nents. The attac�ecl
panel schedule should be everything tl�at the buiidin de artrnent r
e i
� u res,
p
�
Thank you,
5tan
Stanton 0. Humphries, P.E.
Principal
��C
Architectural Engineering Consultants,Inc.
Mechanical, Electrical,&Lighting Design Services
p 970-748-8520 c 970-390-7793
Click on the link logo to view my profile and let's connect!
�..It1�E+E'�t'� �
please consicler environmenfial i���acts be�ore �arin�ir�g t�is �m�ii
From: Adam Johnson [mailto:AJohnsonCa�vailgov com]
Sent: Thursday, June 05, 2014 2:38 PM
To: Stanton O Humphries
Subject: Complete month of Vail PD/Muni panel load
Nere is the infc��ar�t��e tataJ mc�nth of r�adings. Let rne lcnc�w if everytl�in�stidl looks�c�s�d ar�d we ar�abfe te� r�1�ve
forward with a stamped drawing for that par�el.
If sorr�et��in� is different and we nc�ed tn iaak at ��c�rc� c�ptians Ic�t me� kr�c��,v ASAP. Thanks
Adam
From: Eric Olson _ _ _ °.
Sent: Thursday, June 05, 2014 1:49 PM
To: Adam)ohnson
Subject: Excel file
' �
������� � .
��.,;
�'� Department of Community Development
75 South Frontage Road
TOWN OF VAI� � �i �' va�i, co s�ss�
Tel: 970-479-2128
www.vailgov.com
Development Review Coordinator
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm & sprinkler)
Project Street Address: Project#: ���I��-O C� � �
C�n[� 7.S' S !=2�N r�u>e 'LZ s� in1
' DRB#:
(Number) (Street) (Suite#) � r,
{� Building Permit#: �� � `I — ��(:�� .
Building/Complex Name: �u�tet►'r�J_ ��G'E• "�10L�L(��
Contractor Information �,���(��;� Lot#: Block# Subdivision:
Business Name: _ O�v fl� f��� '
Work Class: New( ) Addition ( ) Alteration (�
Business Address: 7,5 c�c��Ty ��p�E �(j
City �/�t'',;L-2� State:�Zip:�ib�� Type of Building:
-�- Single-Family( ) Duplex( ) Multi-Family( )
Contact Name: Ja N�v l�L,c�l.• Commercial (�) Other( )
Contact Phone: Q"7(`l •� �7`�-�! 7�
Contact E-Mail: �1�2��� ��L(_Goo'; C:UM
Work Type: Interior(X) Exterior( ) Both( )
I hereby acknowledge that I have read this application,filled out Valuation of
in full the information required,completed an accurate plot plan, Work Included Plans Included Work
and state that all the information as required is correct. I agree to Electrical (X)Yes ONo (3C)Yes ONo .0 Gb��"r''
comply with the information and plot plan,to comply with all Town
ordinances and state laws, and to build this structure according to Mechanical ( )Yes ( )No ( )Yes ( )No
the town's zoning and subdivision codes, design review ap-
proved, Intemational Building, d Residential Codes and other Plumbing OYes ONo OYes ONo
ordinances of o�rn applica le ereto.
%" r" Building ( )Yes ( )No ( )Yes ( )No
x � -� -� Value of all work being performed: $ /p�G�f�ia. GY�' ;
ner/Owner's Rep 'entative Signature(Required) (value based on IBC Section 109.3&IRC Sectio�108.3� 1
� !Electrical Square Footage
_ . „ _.. .._ _. _. �_ �.. __
Applicant Information `�M '
Detailed Scope and Location of Work:�..�:-��i 5�-� /(�
Applicant Name: �lJ�ia-r , �c��fv�rcri�' N��v FLo��' �'-L'C-�P z.�tc�,�_S ��"f� �iUd'�*�'
Applicant Phone: ��7lJ- 3�`�'•- 1(��/,� ��,e�l�C�= /vlv,�v'T avct�Lt' 7JVr"e.�':� �.�'CCf'PXK�'.GF'�8
Applicant E-Mail: A.�'a6-fws�'vL� �,4.1't G��'� ��^ �-f>D r/L!°��' �'-Z��.�r�<'11rr✓1 PA�cI� L-�ra
Project Information /�<`P�' Td /✓� t�TL�TS 7FfP.�ovGi� L�f��
Owner Name: �/I�.rL �lo,eliC�1�i�,9�TLZP�e ,1���v�y��t-y 3 tl
"f� ��.R..c'cr�cAc.. �r.1.�s.P� P� �`f f.ro����
Parcel#: �lG�`-(�da�i%--dC/--ca0�
(For Parcel#,contact Eagle County Assessors O�ce at(970328-8640 or visit � �CJJ� 13U XP� � �nC.�.'ZC�-r�aV
www.ea g I ec o u nty.us/pati e) —�;—
(use additional sheet if necessary)�Q7u'L �.-� �-��- ��
For Office Use Only: µ��� ��''"'ee 1"'Y '�'"r�"�"�� r �'?�F"z"r;� ""'"-`
Date Received:
Fee Paid:
Received From:
Cash Check#
CC: Visa/ MC Last 4 CC # exp date:
Auth # .
2013-Feb O1
, . RC4 Multi-Service Poke-Thru Device� by Legr�d Page 1 of 4
ra � �����
designed to be better.
'`' Search
RC4 Multi-Service Poke-Thru Device
RC4
The WalkerC�J RC4 Series is a flush poke-thru device ideal for providing audio/video services to the workstation in an open space,above-grade floor environment.It accepts up to four
ports of connectiviry devices to provide a seamless and aesthetically pleasing interface for voice,data,and fiber optic applications at the point of use.All Walker flush poke-thru
devices come with built-in TopGuardT""protection,an industry-leading design that meets and exceeds UL scrub water exclusion requirements for tile and carpet Floors.All Walker flush
poke-thru devices can be installed on tile,carpet,or wood floors.
' Submit Query ',
Where to buy submit Query ?.
'i��., . 7wee2 :� � .
..�.i..�, .. . .
ra«,�
e� ,� ��,�
"5` 4
a�
� .. ..� n a � �
�1 �m_ . .°'� � '�.
f,_
�:t� � j�a..�.;�,.yr..,«:� �ar.r��.� �.
,�, � � � ..�..�� ..
W6 � � � ��
�z�
��5'fiec�.`��l �F.' Y ��,
�� �.` �✓3 4z�.
':.vH.t' �/'%+'n9.��A'� S�
��`
http://www.l egrand.us/wi remol d/pok�thru-devi ces/surface�poke-thru-devi ces✓mul ti-servi c... 1/22/2014
; RC4 M ulti-Service Pok�Thru Device� by Legrand Page 2 of 4
product gallery
Representative images shown.
AVAILABLE OPTIONS
��
�
�
�:
��
�
u
�
• SPECIFICATIONS
• RESOURCES
• COMPONENTS
features 8� benefits
• An integral design which keeps out water,dirt,and debris from the power and communication compartments.Whenever you see the TopGuard protection icon applied
to any Wiremold product,you will know that the product meets and exceeds the new UL scrub water exclusion requirement.
• Power receptacles wired for two circuits.Four 20A power receptacles are wired with a 6-wire system with individual neutral and ground wires.The 20A receptacles can be
wired as standard receptacles or for isolated ground.The receptacles are UL Listed to U.S.and Canadian safety standards.
• UL Listed and UL Fire Classified to U.S.and Canadian safety standards for tile,terreuo,and the future UL requirements under UL514A and UL514C for the scrub
water exclusion test for carpet and wood floors.This future requirement takes effect June,2003.
• New brushed aluminum flange option.Provides additional color options for better aesthetics.
• Communication connectors can be mounted both flush and recessed.Flexibility to mount fiber optic,coaxial,video,and audio connectors below the finished floor surface
for protection when not in use.Only flush poke-thru device in the industry that supports fiber optic connectors and quad power.
• "Step-on-iY'installation.Allows quick and simple installation without additional fasteners.Labor savings provided by eliminating the need for a second installer.All wiring can
be completed at floor level.
• Individual slide covers and"Dead-front"protection.Slide covers protect power and communication devices.Power slide covers snap back in place when power receptacles
are not in use to prevent water,dirt,and debris from entering device.Flexibility to activate either power or communication services simultaneously or individually.
• Suitable for use in air hand�ing spaces in accordance with Sec 300-22(C)of the National Electrical Code.
• Datacom connectivity options.Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing
interface for voice,data,audio,and video applications at the point-of-use.A wide selection of data and bezel options available for use with Ortronics OO ,TracJack�,and
Series II devices.
• Meets ADA Accessibility Guidelines.Even though ADA does not specifically cover floor boxes or poke-thru devices,the wide trim flange on the product is designed to meet
the ADA Accessibiliry Guidelines as it pertains to ADA Standard 4.5 which addresses changes in ground and floor surface levels.The poke-thru trim flanges are beveled so the
slope is no greater than a 1:2 ratio.
Top 5 Resources
RC4 Series Poke-Thru Devices Qnstallation Instructions)
RC4 Series Multi-Service Poke-Thru Device Abandonment Fittings-ABPLUG3,ABPLUG4(Installation Instructions)
RC4 Series Replacement Scrub Water Kit pnstallation Instructions)
RC4 Series Multi-Service Poke-Thru Device Adapters-COM50,COM75(Installation Instructions)
RC3,RC4&RC7 Series Multi-Service Poke-Thru Device Replacement Receptacle-RC37REC,RC4REC2,RC37REG25,RC4REC2-25(Installation Instructions)
specifications
General Info
• Product Series:RC4
• Type:Multi-Service
• Component Type:Full Assemblies
Dimensions
• Hole Size:4"
� i ✓� �� ��� �.'��� 5� ,�.�����v
� �� r�" � � v, �
� ' _� ��
e � �
������...?_ii� _, � __
Buy American Act Compliance
• Cauntry of Origin:MEXICO
• Buy American Act Status:Trade Agreement Act Compliant
f�XJ
�4ll
r
� � �
'�,f
`�..����
resources
http://www.l egrand.us/wi remol d/pok�thru-devi ceslsurfac�pok�thru-devi ces/mul ti-servi c... 1/22/2014
, RC4 M ulti-Service Pok�Thru Device� by Legrand Page 3 of 4
BROCHURE
Poke-ThruPDF(8mb)
Wiremold Open Space BrochurePDF(1.21mb)
CUTSHEET
Flush Style Poke-Thru Devices PDF(2.1 mb)
Chicago Approved Poke-Thru DevicesPDF(953.12kb)
CAD DRAWINGS
> RC7 Series Communication Adapter-COM50DXF(90.56kb)
-'! RC4 Series Abandonment Plate-RC4APTCDXF(147.28kb)
? RC4 Series Assembled Poke-Thru Device-RC4A(RT)TCDXF(1.68mb)
!� RC4 Series Poke-Thru Device-RC4ARTTGLJBDXF(1.46mb)
!� Surface Style Poke-Thru-RC4ATCDXF(1.68mb)
� RC4 Series Surface Style Poke-Thru-RC4ATC(LJB)DXF(1.47mb)
� RC4 Series Finish Flange 8 Slide Holder Assembly-RC4CRTTCDXF(1.03mb)
� RC4 Series Poke-Thru Device Finish Flange&Slide Holder Assembly-RC4CTCDXF(1.03mb)
� RC4 Series Poke-Thru Device Retrofit Kit-RC4KTCDXF(1.16mb)
� RC4 Series Poke-Thru Devic Slide Holder-RC4SHTCDXF(985.62kb)
'� RC4 Series Recessed Floor Box-RC4SRTTCDXF(948.41 kb)
'> RC4 Series Insert Assembly with Disposable Plate-RC4STCDXF(948.41 kb)
INSTALLATION INSTRUCTIONS
RC4 Series Poke-Thru DevicesPDF(773.22kb)
RC4 Series Multi-Service Poke-Thru Device Abandonment Fittings-ABPLUG3,ABPLUG4PDF(262.94kb)
RC4 Series Replacement Scrub Water KitPDF(554.16kb)
RC4 Series Multi-Service Poke-Thru Device Adapters-COM50,COM75PDF(114.13kb)
RC3,RC4&RC7 Series Multi-Service Poke-Thru Device Replacement Receptacle-RC37REC,RC4REC2,RC37REC-25,RC4REC2-25PDF(1010.83kb)
BIM MODELS
RC4 SeriesZlP(3.83mb)
GUIDE FORM SPECIFICATIONS
Flush Poke-Thru Devices-RC7,RC9,RC9AMD,RC3,RC4,AMD8,AV3DOC(131.5kb)
Flush Poke-Thru Devices-RC7,RC9,RC9AMD,RC3,RC4,AMD8,AV3DOC(131.5kb)
SUPPORTING DOCUMENT
cULus Fire ClassificationPDF(173.69kb)
' RC4 Series PaA List-COOXLS(96kb)
ULC Fire ClassifcationPDF(162.97kb)
ONLINE RESOURCES
" Wiremold Spec Wizard-16130
components
�
RC4CTCBK,RC4CTCGY,RC4CTCW,RC4CTCAL,RC4CTCBS,RC4CTCAB,RC4CTCAA
RC4 Multi-Service Poke-Thru Finish Flange&Slide Holder Assembly
�
�
RC4SHTCBK,RC4SHTCGY,RC4SHTCVY,RC4SHTCBS,RC4SHTCAL
RC4 Multi-Service Poke-Thru Device Slide Holder Assembly
�
RC4APTCBK,RC4APTCGY,RC4APTCVY,RC4APTCBS
RC4 Multi-Service Assembled Poke-Thru Device Abandonment Plate
''�,:
�vs
COM75
RC7 Multi-Service Assembied Poke-Thru Device Communication Adapter
�'
1
RC4KTCBK,RC4KTCGY,RC4KTCVY,RC4KTCAL,RC4KTCBS
RC4 Multi-Service Assembled Poke-Thru Device Retrofit Kit
http://www.l egrand.us/wi remol d/pok�thru-devi ces/surfac�pok�thru-devi ces/mul ti-servi c... 1/22/2014
w . . RC4 Multi-Service Pok�Thru Device� by Legrand Page4 of 4
�`4
RC4REC2
RC4 Multi-Service Assembled Poke-Thru Device Replacement Receptacle
'I I�'
RC4REC2-25
RC4 Multi-Service Assembled Poke-Thru Device Replacement Receptacle
�'
ABPLUG4
AMD8 Communications Poke-Thru Device Abandonment Plug Assembly
http://www.l egrand.us/wi remol d/pok�thru-devi ces/surFao�pok�thru-devi ces/mul ti-servi c... 1/22/2014