HomeMy WebLinkAboutB13-0490 REV1 letter � merican
���� Request for Information
onstructors
American Civil Constructors, Inc.
4901 S.W indermere Littleton CO 80120 Phone:303-795-2582 FAX 303-797-0798
Project Name: Ford Park Phase 1 B
Project Location: 530 S. Frontage Rd. East
Date: November 25, 2013
Project Number:
ACC Project Number: 2033901
RFI #: 4
Inquiring Company: AMERICAN CIVIL CONSTRUCTORS, INC.
4901 S. Windermere
Littleton, CO 80120
Inquiry By: Galle os
Subject: Bus Shelter Foundation Walls
Cost Impact:
Schedule Impact: NO
Answer Company: Martin 8� Martin
Attention: Justin Yarnell
CC: Company Name:
Contact Name:
The foundation wall on the north side of the bus shelter that the column
posts rest on was poured 4" north of where it should have been located.
Gallegos has proposed adding 4" of concrete with anchors to the adjacent
Question: corners so the posts will line up. Is this an acceptable solution?
Answer Required: Yes
Answer: It is our understanding that this wall is already poured, as such
4" of additional concrete is not acceptable as the structural engineer
is concerned it will fail due to frost. See attached sketch SK-1 for
structural solution to provide steel support to move the posts such
that they align, fill in between the stone and concrete with 4" add'I grout.
Date Answered: January 13, 2014
1 r�erican
i�uil
anstructors
�tt�-o�T��t�i
Projec#Name: Ford Park Improverr�ents
Project A�ddress: 530 S Frontage Rd East,Vail CO
Ca'itracta's Name and A�ddress:Arrierican G1vil Constructors:4901 S.Windermere St. Littleton,Co.80120
Issue: Bus Shelter Foundation Walls
Drawing or Spec:ification Section Number: 30 3000 Cast in Place Cor�crete
Revised Foundation PIan: 1/12l2014
FrarY Martin/Martin Inc.
PllOrle: 970.926.6007
Fax: 970.765.8198
Number of Submittals: �
Reviev�d By:
John RamSey, PM