HomeMy WebLinkAboutF14-0006 resubmit required113 heads for this project
41 heads for lower level
37 heads for main level
35 heads for upper level
51
5
1
B
a
n
n
o
c
k
S
t
.
De
n
v
e
r
,
C
O
8
0
2
1
6
30
3
-
2
9
1
-
1
0
1
2
30
3
-
3
8
3
-
5
0
2
3
F
A
X
fi
r
e
s
p
r
i
n
k
l
e
r
@
a
f
s
s
c
o
.
c
o
m
A
F
I
R
E
S
P
R
I
N
K
L
E
R
DE
S
I
G
N
C
O
M
P
A
N
Y
MI
L
E
H
I
G
H
DE
S
I
G
N
G
R
O
U
P
MIS-REPRESENT THE EXACT LAYOUT OF THE
LAYOUT & CALCULATIONS.
AID THE AUTHORITY HAVING JURISDICTION WITH
SPRINKLER SCHEMATIC MAY IN SOME CASES
SPRINKLER SYSTEM. IT IS INTENDED TO HELP
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -
THIS SET OF FIRE SPRINKLER SHOP
DRAWINGS HAVE BEEN REVIEWED
AND FOUND TO BE ACCEPTABLE BY
TIMOTHY N. TROSTEL, JR - N.I.C.E.T.
IV # 102055. SR. ENGINEERING
TECHNICIAN - FIRE PROTECTION
NATIONAL INSTITUTE FOR CERTIFICATION IN
ENGINNERING TECHNOLOGIES
____________________________________/____/____
RE
S
N
I
C
K
R
E
S
I
D
E
N
C
E
Va
i
l
V
i
l
l
a
g
e
S
u
b
d
i
v
i
s
i
o
n
,
F
i
l
i
n
g
N
o
.
7
,
B
l
o
c
k
5
,
L
o
t
2
10
2
7
P
t
a
r
m
i
g
a
n
R
o
a
d
,
V
a
i
l
,
C
O
8
1
6
5
7
GARAGE
Flush
21
2" Single
FDC
Horn &
Strobe
Check
Valve
2" COPPER PIPE
pendent head
in ceiling
SCALE:
FDC Detail
not to scale
sidewall head
under garage door
SECTION VIEW A
1/8"=1'-0"
2" COPPER PIPE
WITH 3 SPACERS
WITH NO SPACERS
(127.0 mm)
5" DIA.
UP TO
#1752
THREE
SPACERS
(2)
(1)
1.70" (43.2 mm) MAX.
1.48" (37.6 mm) MIN.(1)
(2)
DIAMETER DETERMINED
BY CLEARANCE FOR
REDUCING COUPLING
1-3/16"
(30.2 mm)
1.11" (28.2 mm) MIN.
1.33" (33.8 mm) MAX.
(2)
(1)
SPORT COURT
001
STORAGE
002
STORAGE
003
ELEVATOR MECH.
004
EXERCISE ROOM
005
EXERCISE
BATHROOM
006
W.C.
007
STEAM ROOM
008
REC ROOM
009
PASS THROUGH
BAR
010
BATHROOM
011
GUEST ROOM #2
012
GUEST CLST
013
GUEST
BATHROOM #2
014
GUEST ROOM #1
016
GUEST BATH #1
017
W.C.
018
GUEST CLOSET
019
MECHANICAL
020
A/V CLOSET
021
OPEN AREA
023
LAUNDRY /
CHANGING
024
ELEVATOR
025
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
T.O. DECKING A.F.F. 9' - 7 7/8"
B.O. GWB A.F.F. 9' - 9"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 10' - 10 7/8"
B.O. GWB A.F.F. 9' - 9"
B.O. GWB A.F.F. 9' - 4 7/8"
B.O. GWB A.F.F. 10' - 6 3/8"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 9' - 10 7/8"
B.O. DECKING A.F.F. 10' - 1 7/8"
B.O. GWB A.F.F. 10' - 4 3/8"
B.O. GWB A.F.F. 9' - 10 7/8"
T.O. DECKING A.F.F. 10' - 2 3/4"
4" underground- by others
DA Name: 2
DA Area: 625.47
90.00 0.00
21.03 851.50
113 heads for this project
41 heads for lower level
37 heads for main level
35 heads for upper level
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
JSPIWð/PLQPðRIIORRUDUHDRYHU
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at at the base of the riser.
Hose stream allowance of is included in the above.
2 GYM
Phoenix Automatic
Resnick Res 1027 Ptarmigan Rd
0.1
IWð 93 gpm 42.2 psi
DWELLING 4
Wet
11.63 ft/s
0 gpm
93 gpm
0 gpm
0 gpm
0 gpm
93 gpm
0 gpm
93 gpm
42.2 psi
88.9 psi
46.6 psi
MI
L
E
H
I
G
H
DE
S
I
G
N
G
R
O
U
P
51
5
1
B
a
n
n
o
c
k
S
t
.
De
n
v
e
r
,
C
O
8
0
2
1
6
30
3
-
2
9
1
-
1
0
1
2
30
3
-
3
8
3
-
5
0
2
3
F
A
X
fi
r
e
s
p
r
i
n
k
l
e
r
@
a
f
s
s
c
o
.
c
o
m
A
F
I
R
E
S
P
R
I
N
K
L
E
R
DE
S
I
G
N
C
O
M
P
A
N
Y
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -
THIS SET OF FIRE SPRINKLER SHOP
DRAWINGS HAVE BEEN REVIEWED
AND FOUND TO BE ACCEPTABLE BY
TIMOTHY N. TROSTEL, JR - N.I.C.E.T.
IV # 102055. SR. ENGINEERING
TECHNICIAN - FIRE PROTECTION
NATIONAL INSTITUTE FOR CERTIFICATION IN
ENGINNERING TECHNOLOGIES
____________________________________/____/____
RE
S
N
I
C
K
R
E
S
I
D
E
N
C
E
Va
i
l
V
i
l
l
a
g
e
S
u
b
d
i
v
i
s
i
o
n
,
F
i
l
i
n
g
N
o
.
7
,
B
l
o
c
k
5
,
L
o
t
2
10
2
7
P
t
a
r
m
i
g
a
n
R
o
a
d
,
V
a
i
l
,
C
O
8
1
6
5
7
1/8" = 1'-0"
LOWER LEVEL FIRE SPRINKLER PLAN
3 heads
T/S T/S
Riser Detail
not to scale
1
1
/
2
"
/
1
2
"
T.O. DECKING A.F.F. 10' - 6 1/4"
T.O. GWB A.F.F. 12' - 11 7/8"
T.O. GWB A.F.F. 15' - 11 3/8"
GARAGE
101
MUDROOM
102
LAUNDRY ROOM
103
FAMILY OFFICE
108
PANTRY
105
SECONDARY
KITCHEN
104
POWDER
107
KITCHEN
106
HEARTH ROOM
109
BREAKFAST
NOOK
110
ENTRY
111 ENTRY CLST.
112
DINING ROOM
113
BAR
114
LIVING ROOM
115
ELECTRICAL
CLOSET
118
POWDER
116
ELEVATOR
117
B.O. GWB A.F.F. 9' - 8 1/8"
B.O. DECKING A.F.F. 10' - 2 3/4"
B.O. DECKING A.F.F. 9' - 11 3/4"
B.O. GWB A.F.F. 8' - 6"
B.O. DECKING A.F.F. 10' - 2 3/4"
STOR.
117
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 10' - 0 7/8"
B.O. GWB A.F.F. 10' - 6 3/8"
open to
above
open to
above
fire department
connection. See FP0
for details.
B.O. GWB A.F.F. 7' - 5 1/8"
2" / 12"
1
1
/
2
"
/
1
2
"
1 1/2"
/
1
2
"
1
1
/
2
"
/
1
2
"
1 1/2" / 12"
2" / 12"
1 1/2"
/
1
2
"
MASTER
BEDROOM
201
MASTER
BATHROOM
202
W.C.
203
ERIC'S CLOSET
205
SARA'S CLOSET
206
EMMA'S ROOM
207
ERIC'S OFFICE
210
MICHAEL'S ROOM
212
MICHAEL'S BATH
213
MICHAEL'S CLST.
214
ALLIE'S ROOM
215
ALLIE'S BATH
216
ALLIE'S CLST.
217EMMA'S BATH
208
EMMA'S CLST
209
STORAGE
218
ELEVATOR
219
1 1/2"
/
1
2
"
B.O. GWB A.F.F. 9' - 9 5/8"B.O. GWB A.F.F. 11' - 8 1/2"
1 1/2" / 12"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 10' - 0"
B.O. DECKING A.F.F. 8' - 10 5/8"
B.O. DECKING A.F.F. 7' - 3 1/4"
B.O. GWB A.F.F. 8' - 6"
B.O. DECKING A.F.F. 8' - 10 1/8"
B.O. DECKING A.F.F. 11' - 3"
1 1/2"
/
1
2
"
[No Slope]
B.O. GWB A.F.F. 7' - 6"
B.O. GWB A.F.F. 8' - 5 1/2"
B.O. GWB A.F.F. 8' - 6"
8' - 6"
B.O. GWB A.F.F. 9' - 0"
B.O. GWB A.F.F. 12' - 1 3/8"
2" / 12"
B.O. GWB A.F.F. 9' - 0"
B.O. GWB A.F.F. 10' - 3 7/8"
B.O. GWB A.F.F. 13' - 1 7/8"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
B.O. GWB A.F.F. 8' - 6"
8' - 0"
2" / 12"
SHOWER
DA Name: 1
DA Area: 390.39
113 heads for this project
41 heads for lower level
37 heads for main level
35 heads for upper level
This system as shown on company print no dated
for at
contract no is designed to discharge at a rate of
a maximum area of when supplied with water at a rate of
Occupancy classification:
Commodity classification:
Maximum storage height:
Storage arrangement:
Number of heads flowing:
System Type:
Maximum velocity:
Flow from In-Rack sprinklers:
Flow from Overhead sprinklers:
Flow from Inside Hoses:
Flow from Outside Hoses:
Other fixed flows:
Total flow in system piping:
Additional flow at/beyond source:
Total of all flows:
Calculation results for Design Area
JSPIWð/PLQPðRIIORRUDUHDRYHU
-
Surplus Pressure at Source:
Pressure Required at Source:
Pressure Available at Source:
at at the base of the riser.
Hose stream allowance of is included in the above.
1 Allie's Rm
Phoenix Automatic
Resnick Res 1027 Ptarmigan Rd
0.05
IWð 56.4 gpm 77.2 psi
Res 4
Wet
20.7 ft/s
0 gpm
56.4 gpm
0 gpm
0 gpm
0 gpm
56.4 gpm
0 gpm
56.4 gpm
77.2 psi
89.5 psi
12.3 psi
MI
L
E
H
I
G
H
DE
S
I
G
N
G
R
O
U
P
51
5
1
B
a
n
n
o
c
k
S
t
.
De
n
v
e
r
,
C
O
8
0
2
1
6
30
3
-
2
9
1
-
1
0
1
2
30
3
-
3
8
3
-
5
0
2
3
F
A
X
fi
r
e
s
p
r
i
n
k
l
e
r
@
a
f
s
s
c
o
.
c
o
m
A
F
I
R
E
S
P
R
I
N
K
L
E
R
DE
S
I
G
N
C
O
M
P
A
N
Y
ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS,
INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION
CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE
UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL
IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR
EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR
AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY
TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION
CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR
INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE
COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND
STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN
GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH
ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED
THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED
BY MILE HIGH DESIGN GROUP, LLC
THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT
FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -
THIS SET OF FIRE SPRINKLER SHOP
DRAWINGS HAVE BEEN REVIEWED
AND FOUND TO BE ACCEPTABLE BY
TIMOTHY N. TROSTEL, JR - N.I.C.E.T.
IV # 102055. SR. ENGINEERING
TECHNICIAN - FIRE PROTECTION
NATIONAL INSTITUTE FOR CERTIFICATION IN
ENGINNERING TECHNOLOGIES
____________________________________/____/____
RE
S
N
I
C
K
R
E
S
I
D
E
N
C
E
Va
i
l
V
i
l
l
a
g
e
S
u
b
d
i
v
i
s
i
o
n
,
F
i
l
i
n
g
N
o
.
7
,
B
l
o
c
k
5
,
L
o
t
2
10
2
7
P
t
a
r
m
i
g
a
n
R
o
a
d
,
V
a
i
l
,
C
O
8
1
6
5
7
1/8" = 1'-0"
MAIN LEVEL FIRE SPRINKLER PLAN
1/8" = 1'-0"
UPPER LEVEL FIRE SPRINKLER PLAN