HomeMy WebLinkAboutF14-0007 cut sheets Bulletin 006 Rev. H Model RFC30 (SIN RA0611) 07 � Q Model RFC43 (SIN RA0612) �. Model RFC49 (SIN RA0616) o Residential Flat Concealed � � Sprinklers = A Residential Flat Concealed Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. ' , Features 1. Very low water flow requirements. 2. Cover plate attachment (Plain or Perforated) with '/2" (13mm) Total adjustment. 3. Thread-On/Thread-Off or Push-On/Thread - Off cover attachment option. `"� 4. Smooth aesthetic ceiling profile. ` ...... . .... :..:. ,.,--- 5. Available in brass, chrome and black plated or painted finishes. P�ain Cover P�ate Listings & Approval 1. Listed by Underwriters Laboratories, and � '�� certified by UL for Canada (cULus) �* _�„�„ ��"�� � .� � --- -_� UL Listing Categories Residential Automatic Sprinklers ==- =' '- =- - UL Guide Number = = " ="-=--=- Application and Installation The RFC30, RFC43 and RFC49, for residential instal- �/�/hen inserting or removing the wrench from the sprin- lations, use a 165°F (74°C) fusible solder link in a tun- kler/cup assembly, care should be taken to prevent dam- ing fork style sprinkler frame with a drop-down deflector. age to the sprinkler. DO NOT WRENCH ON ANY OTHER This assembly is recessed into the ceiling and concealed PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL by a flat cover plate. The cover plate is attached to the RFC30, RFC43 AND RFC49 CONCEALED SPRINKLERS skirt, using 135°F(57°C) ordinary temperature classifica- MUST BE INSTALLED ONLY WITH 135°F RATED COV- tion solder.When the ceiling temperature rises, the solder ERS. holding the cover plate releases the cover allowing the Note:A leak tight'/z" NPT(R1/2) sprinkler joint can be ob- deflector to drop into position and exposing the sprinkler tained with a torque of 8-18 ft-Ibs (10,8- 24,4 N-m). Do not inside to ceiling temperature. The subsequent operation tighten sprinklers over maximum recommended torque. It of the solder link opens the waterway and causes the de- may cause leakage or impairment of the sprinklers. flector to drop into position to distribute the discharging Cover assemblies provide up to '/2" (13mm) of adjust- water in a hemispherical pattern below the sprinkler de- ment. Turn the cover clockwise until the flange is in con- flector. Any adjustment of thread engagement between tact with the ceiling. For the push-on/thread-off option, the cover plate and cup will assure that the drop-down the cover assembly is pushed onto the cup and final ad- deflector is properly located below the ceiling. The resi- justment is made by turning the cover clockwise until the dential distribution pattern contains a finer droplet size skirt flange makes full contact with the ceiling. Cover re- than a standard sprinkler, and the pattern produces sig- moval requires turning in the counter-clockwise direction. nificantly higher wall wetting. In ceilings that have a plenum space above the sprin- After a 25/S inch diameter hole is cut in the ceiling, the kler, the plenum space may have neutral or negative sprinkler is to be installed with the Model FC Wrench. pressurization but must not be positively pressurized. When installing a sprinkler, the wrench is first positioned Inspect all sprinklers after installation to ensure that the into the sprinkler/cup assembly and around the hexago- gap between the cover plate and ceiling and the 4 slots nal body of the sprinkler frame. The Wrench must bottom in the cup are all open and free from any air flow impedi- out against the cup in order to ensure proper, safe instal- ment. lation. The sprinkler is then tightened into the pipe fitting. S rinkler CCP Assembl Max. Thread Nominal p � Y Max. Model Tem Ratin Tem Ratin Ambient K (SIN) Size Orifice p g p� g Temp. Factor Pressure Inch(mm) Inch (mm) psi (bar) �"F wC �'F wC �F wC RFC 30 y?„�15� 21/s4(8,2) 165 74 135 57 100 38 3.0 175(12) (RA0611) RFC 43 i�2„(15) 3/s(10) 165 74 135 57 100 38 4.3 175(12) (RA0612) RFC 49 (RA0616) �2 �15� '/,6(11) 165 74 135 57 100 38 4.9 175(12) Note: 1 bar= 100 Kpa RFC 30 Ordinary Temp. Rating Max.Coverage Max. Spacing (165�'F/74'�"C) Top of Deflector Installation Minimum area to Ceiling Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Inch(mm) Type Ft(m) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 9(34,1) 9.0(0,62) Smooth Ceilings Yz to 1(13 to 25.4) Beamed Cei�ings per NFPA 13D, 13R or Concealed 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11.0(0,76) 13 installed in beams Yz to 1(13 to 25.4) For Ceiling types refer to NFPA 13, 13R or 13D 2. RFC 43 Ordinary Temp. Rating Max.Coverage Max. Spacing (165�'F/74'�C) Top of Deflector Installation Minimum area to Ceiling Spacing Ft x Ft(m x m) Ft(m) Flow Pressure Inch (mm) Type Ft(m) GPM (Umin) PSI(bar) 12 x 12(3,6 x 3,6) 12(3,6) 12(4,5) 7.8(0,54) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 9.1 (0,63) Smooth Ceilings Y2 to 1(13 to 25.4) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 9.1 (0,63) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) 13 installed in beams Y2 to 1(13 to 25.4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68) 17.5(1,21) 20 x 20(6,1 x 6,1) 20(6,1) 21 (79) 23.8(1,64) For Ceiling types refer to NFPA 13, 13R or 13D RFC 49 Ordinary Temp. Rating Max. Coverage Top of Deflector Minimum Max. Spacing 165�'F/74'NC) Installation area Ft(m) Flow Pressure to Ceiling Type Spacing Ft x Ft(m x m) GPM (Umin) PSI(bar) �nch (mm) Ft(m) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0(0,48) 14 x 14(4,3 x 4,3) 14(4,3) 13(49) 7.0(0,48) Smooth Ceilings Yz to 1(13 to 25.4) 16 x 16(4,9 x 4,9) 16(4,9) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 13R or Concealed 8(2,4) 13 installed in beams Yz to 1(13 to 25.4) 18 x 18(5,5 x 5,5) 18(5,5) 17(69,3) 12.0(0,83) 20 x 20(6,1 x 6,1) 20(6,1) 20(75,73) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model RFC30, RFC43 and RFC49 Concealed Sprin- symmetric lever mechanism, maintaining a Teflon-coated klers should be inspected and the sprinkler system Belleville spring washer and machined brass cap water maintained in accordance with NFPA 25. Do not clean seal assembly containing no plastic parts. Sprinkler sprinklers with soap and water, ammonia or any other K-factor shall be nominal 3.0 (44), 4.3 (62.4), and 4.91 cleaning fluids. Remove dust by using a soft brush or (70) having a 5/,6°, 3/8" and '/,6" orifice. Temperature rating gentle vacuuming. Remove any sprinkler cover plate as- shall be Ordinary 165°F(74°C); cover plate temperature sembly which has been painted (other than factory ap- rating to be 135°F(57°C). Cover plate assembly shall plied) or damaged in any way. A stock of spare sprin- consist of a brass cover plate and copper alloy retainer klers should be maintained to allow quick replacement flange allowing a'/2" cover plate adjustment. Any secure of damaged or operated sprinklers. Prior to installation, engagement between the cover plate and the cup will sprinklers should be maintained in the original cartons assure that the drop-down deflector is properly located and packaging until used to minimize the potential for below the ceiling. A plastic protective cap shall be damage to sprinklers that would cause improper opera- provided and factory installed inside the sprinkler cup tion or non-operation. to protect the drop-down sprinkler deflector from dam- Model RFC30, RFC43 and RFC49 Residential age, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] Concealed Sprinkler Specification [White] [Specialty—specify]. Residential concealed sprinklers shall be Reliable Model RFC30, SIN RA0611 Sprinklers shall be cULus Listed low flow residential con- (gulletin 006), Model RFC43, SIN RA0612 (Bulletin 006) cealed sprinklers with drop-down deflector and adjust- or Model RFC49, SIN RA0616 (Bulletin 006). able flat cover plate engineered for a minimum design density of 0.05 gpm/ft2. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with 3. Ordering Information Cover Plate Finishes�'> Specify: Standard Finishes - 1. Sprinkler Model Chrome �. _— _ 2. Cover Plate Finish White Paint 3. Thread-On or Special Application - Push-On Feature Finishes�2� �i _ _ 1 - Bright Brass ,� �* � Finished Bronze - i :' Black Plating I i � Black Paint AI; � Off White "�" Satin Chrome �'� Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is �� semi-gloss, unless specified ����� otherwise. �2� For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. 7" x 7/2" REDUCING T_FF Ol7 ELBOW �� ( --��-----��__� ���� ���� ���� ���� � ��� �� '� �" �66.SSmm] 25" [5�.42mm] plA I I NOLE /N CE/L/NG '7� � � � �_ �rJF_`_ . i—==__ l 2" [50.8mm� MAX. FACE OF FITTING ,���� _��� � 'i TO FACE OF CEIUNG i �„ . -. � �������� I�I � DIMENSION �������� �._ =-r I i� �i: :i� iiiiiii�� CEILING� �---- � i i i i i i � �` �72.70mrn] MAX. � �� - � � � 3° 4 96mm CO�ER ADJUS7MEN7 76 � � � FLAT COl/ER PLA7E 5�- ASSEMBLY �316 �84.27mm� DIA. SPkINKLER aoeFCO�e COV_FR PLA7-_F.� ��2" ��2. 7mm ] A�,JUS�MFN� The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and properry for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,Inc. � Recycled � � (800)431-1588 Sales Offices Paper � '� � (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in u s A. 10/13 P/N 9999970261 Bulletin 176 Rev. C � c � Q Model F1 � � Residential Sprinklers for � Design Density of .10 gpm/ft2 � � Model F1 Res Sprinklers Listed to meet the minimum design density as required by UL1626. `��� � Types: � � '�,�° 1. F1 Res 30 Pendent '�" -��r `r'� _ u-? �� � � � 2. F1 Res 30 Recessed/F2 ° - �=�- 3. F1 Res 30 Recessed/FP '' 4. F1 Res 30 CCP Pendent F1 Res 30, 49, 58 & 76 F1 Res 30, 49, 58 & 76 5. F1 Res 49 Pendent Recessed Pendent/F1 Recessed Pendent/FP 6. F1 Res 49 Recessed Pendent/F1 7. F1 Res 49 Recessed Pendent/FP . sx'' 8. F1 Res 49 CCP Pendent � ,�� 9. F1 Res 58 Pendent � ''" ,p � • 10.F1 Res 58 Recessed Pendent/F1 Nr �� 11.F1 Res 58 Recessed Pendent/FP ..__ -;�.=, 12.F1 Res 58 CCP Pendent ' 13.F1 Res 44 & 58 HSW F1 Res 30, 49, 58 & 76 F1 Res 58 HSWX 14.F1 Res 44 & 58 HSW Recessed HSW/F2 CCP Pendent 15.F1 Res 58 HSWX 16. KRes58 HSWX 17.F1 Res 44 SWC ' � � � ��� �-� � ��.� 18.F1 Res 76 Pendent "� � j � 19.F1 Res 76 Recessed Pendent/F1 � � 20.F1 Res 76 Recessed Pendent/FP 21.F1 Res 76 CCP Pendent F1 Res 44 & 58 F1 Res 44 SWC Listings & Approvals Recessed HSW/F2 1. Listed by Underwriters Laboratories Inc. and The 3mm glass-bulb pendent sprinklers permit the ef- UL Certified for Canada (cULus) ficient use of residential water supplies for sprinkler cover- 2. NYC MEA 258-93-E age in residential fire protection design. UL Listing Category Upon fire conditions, rising heat causes a sprinkler's heat-sensitive glass-bulb to shatter, releasing the water- Residential Automatic Sprinkler way for water flow onto the deflector, evenly distributing UL Guide Number the discharged water to control a fire. VKKW Technical Data: Patents • Thermal Sensor: Nominal 3mm glass-bulb US Patent No. 6,516,893 applies to the Model F1 Res 49 . Sprinkler Frame : Brass Casting & 58 Pendent Sprinklers • Sprinklers' Pressure Rating : 175 psi US Patent No. 7,353,882 applies to Model F1 Res 44 & Factory Hydrostatically Tested to 500 psi 58 HSW Sprinklers • Thread Size: 'h° NPT (R'/z) US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinkler • K-Factor: 3.0(Actual)-F1 Res 30 Pendent Sprinkler Patent Pending - Model F1 Res 76 Pendent Sprinkler 4.9(Actual)-F1 Res 49 Pendent Sprinkler 5.8(Actual) - F1 Res 58 Pendent&HSW/HSWX Product Description Sprinkler Model F1 Res Pendent sprinklers (Figs. 1, 2, 3 & 4) 7.6(Actual)-F1 Res 76 Pendent Sprinkler combine excellent durability, high sensitivity glass-bulb 4.4(Actual)-F1 Res 44 HSW Sprinkler and low profile decorative design. • Density: Minimum 0.10 gpm/ftz The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res Sprinklers are used for Residential Fire Pro- K=7.6) that will provide lower pressure demands for tection according to UL 1626 Standard. Be sure that orifice 0.1 gpm/ftz densities in NFPA 13 residential applica- size, temperature rating, deflector style and sprinkler type tions. are in accordance with the latest published standards of Example No. 1 The National Fire Protection Association or the approving Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) authority having jurisdiction. Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) When using F1 Residential Sprinklers for systems designed Flow C� 0.10 gpm/ftz density= 240 x 0.10 = 24 gpm to NFPA 13D or NFPA 13R, use listed area of coverage and Using an F1 Res 49 Pendent Sprinkler, K=4.9 minimum flow and pressure requirements shown in Bulletin Pressure= (24/4.9)z = 24 psi (1.65 bar) 135. The baseline flow for a 20 ft x 20 ft(6.1 m x 6.1 m) cover- For systems designed to NFPA 13, use information in this age area using the baseline density of 0.05 gpm/ft2 will bulletin. The number of design sprinklers shall be the most be 20 gpm C 16.7 psi (75.7 L/min @ 1.14 bar). There- hydraulically demanding sprinklers as required by NFPA fore, the minimum flow required is 24 gpm @ 24 psi (90.8 13. Flows and pressures can not be below the baseline L/min C 1.65 bar). flows and pressures. NFPA 13 Example No. 2 For residential sprinkler systems designed to NFPA 13, a Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) minimum density of 0.1 gpm/ftz must be provided over the Coverage Area= 8 x 20 = 160 ft (14.9 m2) "design area" that includes the four (4) hydraulically most Flow C� 0.10 gpm/ft density= 160 x 0.10 = 16 gpm demanding sprinklers for the actual coverage areas being Using an F1 Res 49 Pendent Sprinkler, K=4.9 protected by the 4 sprinklers. The minimum required dis- Pressure= (16/4.9) - 10.7 psi (0.74 bar) charge from each of the four most hydraulically demanding The baseline flow for a 20 ft x 20 ft(6.1 m x 6.1 m) cover- sprinklers shall be the greater of the following: age area using the baseline density of 0.05 gpm/ft will 1. The flow rates given in the Reliable Residential be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, Sprinkler Technical Bulletins referenced in Table A the minimum flow required is 20 gpm C� 16.7 psi (75.7 for NFPA 13D and 13R as a function of temperature L/min C� 1.14 bar). rating and maximum allowable coverage area (for actual coverage areas less than or between those Example No. 3 indicated in the respective technical bulletin, it is re- Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) z quired to use the minimum required flow for the next Coverage Area= 10 x 16 = 160 ft2 (14.9 m ) largest coverage area); or Flow C� 0.10 gpm/ft density= 160 x 0.10 = 16 gpm 2. A minimum discharge density of 0.1 gpm/ft2 applied Using an F1 Res 76 Pendent Sprinkler, K=7.6 over the"design area"consisting of the four most hy- The baseline flow for a 16 ft x 16 ft coverage area is 21 draulically demanding sprinklers for the actual cov- gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the erage areas being protected by the four sprinklers. minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 The maximum dimension of the actual coverage area L/min C� 0.52 bar). cannot be any greater than the maximum coverage Example No. 4 area indicated in the technical bulletins referenced Room Size- 14 ft x 18 ft (4.3 m x 5.5 m) in Table A. Coverage Area= 14 x 18 = 252 ftz (23.6 m2) Design Note: Using the As = S x L method to de- Flow @ 0.10 gpm/ftz density- 252 x 0.10 - 25.2 gpm termine the sprinkler protection area of coverage in �g4.6 L/min) accordance with NFPA 13,apply the 0.1 gpm/ft2den- Using an F1 Res 76 Pendent Sprinkler, K-7.6 sity to this area to determine the minimum required Pressure- (252/7.6)2 - 11 psi (0.76 bar) flow. Compare this flow to the minimum 0.05 gpm/ft2 The baseline flow and pressure of an 18 ft x 18 ft cover- cULus Listed flow for the appropriate coverage area age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). in the technical bulletin for the specific residential Therefore, the minimum flow and pressure is 25.2 gpm @ sprinkler. If the flow stated in the technical bulletin 11 si 94.6 L/min @ 0.76 bar is less than the calculated 0.1 gpm/ft2 density flow p � �� required,the .1 density flow must then be used in the �n general residential sprinklers require flows and equation Q=K�1P, solving for P, to establish the mini- pressures as listed for 0.05 densities to achieve the mum required pressure using the sprinkler K-factor. proper spray pattern so the flows and pressures at Note: In many cases the listed flow of individual resi- 0.05 density are the baseline flows and pressures. dential sprinklers may exceed the required minimum Flows and pressures below the listed 0.05 density 0.05 gpm/ft density. Reliable has available resi- shall not be used. dential sprinklers with larger K-factors (K=5.8 and 2. Installation Models F1 Res sprinklers are to be installed as shown. Use of wrenches other than those specified may dam- Model F1, F2 and FP Escutcheons, illustrated herewith, age these sprinklers. are the only recessed escutcheons to be used with Mod- Note: A `leak tighY' sprinkler joint can be obtained with el F1 Res sprinklers. Use of any other recessed escutch- the following torque: eon will void all approvals and warranties. For installing . 3/4" NPT (R3/4)— 14-20 ft-Ibs (19 - 27.1 N-m) Model F1 Res Pendent sprinklers use only the Model D • �/2" NPT (R'/2)—8-18 ft-Ibs (10.8—24.4 N-m) sprinkler Wrench; for installing Models F1 Res Recessed Do not tighten sprinklers over maximum recom- Pendent, CCP sprinklers use only the Model GFR2 sprin- mended torque. It may cause leakage or impairment kler wrench; for installing Model F1 Res recessed HSW of the sprinklers. sprinklers use only the Model GFR2 Sprinkler wrench. • Model F1 Res 30, 49, 58 & • Model F1 Res 30, 49, 58 & 76 76 Pendent Recessed Pendent/ F1/F2 � � � � ,��`.--.�.�.�- '�:. �.� , � . . �..,; --- ��`''� l , � , ,�"""��,��, �� , ��' � �,�.� A:� � � ,,��� - �- . - -,� ,� ��x: �� ���� ����w � . ,�, . i- F1 escutcheon, 3/4" (19mm) adjustment Note: See escutcheon table for dimensions. 2 I/A"HOLE DIA. / \ [5].2mm] I II _ ' I 1 S�i6"OW. _ _ _ [49.2mm� — _ — � —��—. .— � �� � T ITURN COLLlR UNTIL �� � X 1/1""REOUCEF \ IIGHi AGAINST SPRINKLER � I WRENCN BO55. o B II I II FACE OF F/TTMG TO CE/LING D/MEnISION� s/ie—rs/re(vr escurcHEOm) ��� 3/�6—tt/)6(F2 FSLUTCNEON) `� AOJUSTMENT �`�I'�'tl� � / 0���� � - „8. �3_�mm,. I i 135FCC2A 2 2;/32"OIA. [�2 2mmJ I �JJFG�J Fig. 1 Fig. 2 3. Technical Data: F1 Res 30 Pendent and Recessed Pendent(SIN R3511) Thread NominalOrifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Tem . Ratin Ambient Tem . K Length si bar �F wC �'F �C Factor Inch mm Yz" NPT z1�6,"(8.2) 175(12) I 155 68 100 38 3.0 225(57) R'/z 175 79 **Baseline flows and pressures for 0.05 density Ordinary Temp. Rating Intermediate Temp. Rat- Max.Coverage area Max. Spao- (155�'F/68pC) ing (175PF/79pC) Top of Deflector Minimum Flow I to Ceiling Spacing Ft x Ft(m x m) ing Ft(m) Flow Pressure GPM (V Pressure Inch (mm) Ft(m) GPM(Umin) PSI (bar) m�n� PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 8(30,3) 7.0(0,48) 1 to 4(25 to 100); '/z recessed using 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11 (0,76) 10(37,8) 11 (0,76) F2 escutcheon For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1 Res 49 Pendent and Recessed Pendent Nominal Sprinkler Mau. Max. Sprinkler EsCUtCheon*, F1 or F2, Data: Actual Thread Orifice Temp. Pressure Ambient K Length Face of fitting to Size Inch Ratin si Tem . Inch Adjustment "A" (mm) ;°F �'C (bar) r�F N� Factor �mm� Ty� Inch(mm) Inch(mm) Inch(m '/z"NPT ,��s° 11 155 68 175 12 100 38 4.9 2.25 57 3 Min.=3/4(19.1) 3/�s-'s/,s (R'/z) � � 175 79 � � 150 66 � � F1 /4"(19.0) Max.=1'/z(38.1) (4.7-24.0) **Baseline flows and pressures for OA5 density F2 '/2'(12.7) Min.='S�,e(23.8) 3/,s-"hs M�.=1 /z(38.1) (47-17.4) *Note:Escutcheons F1 or F2 may be used with Deflector-to-ceiling Model F1 Res 49&58 Recessed Pendent Sprinkler Maximum 1" (25mm)to 4" (100mm) *Deflector-to- ceiling Mau.Sprinkler Flow Pressure Sprinkler Maximum 4" (100mm)to 8" (203mm) Spacing Identification Max.Sprinkler Sprinkler gpm(Lpm) psi(bar) Flow Pressure ft m Number SIN Spacing Identification 12 x 12(3.6x3.6) 13(49) 7.0(0.48) ft m Jpm(Lpm) psi(bar) Number SIN 14 x 14(4.3x4.3) 13(49) 7.0(0.48) 12 x 12(3.6x3.6) 15(57) 9.4 (0.65) 16 x 16(4.9x4.9) 13(49) 7.0(0.48) R3516 14 x 14(4,3x4,3) 16(60.5) 10.6(0.73) 18 x 18(5.5x5.5) 17(64.3) 12.0(0.83) 16 x 16(4.9x4.9) 17(64.3) 12.0(0.83) R3516 20 x 20(6.1 x6.1) 20(75.7) 167(1.14) 18 x 18(5.5x5.5) 19(72) 15.0(1.0) 20x20(6.1x6.1) 22(832) 20.2(1,4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth=7"(178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m)on center, Technical Data: F1 Res 58 Pendent and Recessed Pendent Sprinkler Temp. Max. Thread Size Nominal Orifice Rating Max. Pressure qmbient Temp. K Sprinkler Length Inch (mm) i°F �C psi(bar) �F �C Factor Inch (mm) '/z" NPT(RYz) '/z"(13) 175 �79 175(12) 160 66 5.8 2.25(57) **Baseline flows and pressures for 0.05 density Max. Sprinkler Spacing Flow Pressure Ceiling-to-Deflector Sprinkler ldentification ft(m) gpm (Lpm) psi (bar) Inch (mm) Number(SIN) 12 x 12(3.6x3.6) 16(61) 7.6(0.53) 14 x 14(4.3x4.3) 16(61) 7.6(0.53) 16 x 16(4.9x4.9) 16(61) 7.6(0.53) (25-00) R3513 18 x 18(5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1 x6.1) 22(83.3) 14.4(1.0) **Calculate for a .10 density but in no case go below the baseline flows & pressures 4. Technical Data: Fi Res 76 Pendent and Recessed Pendent Sprinkler Max. Escutcheon*, F1 or F2, Data: Nominal Max. Sprinkler Thread Temp. Ambient K Face of fitting Orifice Pressure Length Adjustment "A" Size Inch(mm) Ratin psi(bar) Tem . Factor Inch(mm) Ty� Inch(mm) Inch(mm) to ceiling wF i"C �'F wC Inch(mm) �/�"NPT ,��3z(13.5) 155 68 175(12) 100 38 7.6 225(57) F1 3/a(19.0) Min.=3/n(19.1) 3/16-'S/�s(4.7-24.0) (R3/�) 175 79 150 66 Mvc.=1'/z(38.1) F2 '/z(12.7) Min.=,'/,s(23.8) 3�,s-„/,�(4.7-17.4) '`Baseline flows and pressures for 0.05 density M�.=1'/�(38.1) Max.Sprinkler Sprinkler Flow Pressure Spacing Identification *Calculate for a .10 density but in no case go ft m 9pm(Lpm) psi(bar) Number SIN below the baseline flows & pressures 12 x 12(3.6x3.6) 21 7.6(0.53) 14 x 14(4.3x4.3) 21 7.6(0.53) 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 18 x 18(5.5x5.5) 21 7.6(0.53) 20 x 20(6.1 x6.1) 23 92(0.63) • Model F1 Res 30, 49, 58 & • Model F1 Res 30, 49, 58 & 76 CCP Pendent 76 Recessed Pendent/FP - � . � � _ � � - _ � � � �� — �-.,� $ FP push-on/thread-off escutcheon 2 5/B"0/A[66_]mm] 2 5�8'�[o"6Jmm� DIA. Ho�E inr cE�uNc 2 5�16" DIA. HOLE lN CEILING z s�6"o. [SSJmm] �sa_�mm] CUP —�.-� cua � �� -- � � -----� �' L=== Technical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) CCP Assembly Max. Thread Nominal Orifice Max. Pressure K Sprinkler Length Temp. Rating Ambient Temp. Size Inch(mm) psi (bar) ,F �°C wF ,�C Factor Inch (mm) Y2" NPT(R'h) 21/ea"(8.2) i 175(12) 135 57 100 38 3.0 I 2.25(57) *Baseline flows and pressures for 0.05 density Ordinary Temp. Rating Max. Coverage area Max. Spacing (155wF/68�°C) Top of Deflector Minimum Ft x Ft(m x m) Ft(m) Flow Pressure to Ceiling Spacing GPM (Vmin) PSI (bar) �nch (mm) Ft(m) I 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0(0,48) 1 to 4(25 to 100); '/a(13mm)recessed ' 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 11 (37,8) 13.4(0,92) using FP escutcheon For Ceiling types refer to NFPA 13, 13R or 13D "Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP CCP Options Data: Nominal CCP Max. Max. Sprinkler A "B" Sprinkler Ambi- Cover Thread Orifice Assembly Pres- K Length CCP Height Temp. Rating ent Adjustment Size Inch Temp. Rating sure Tem Factor Inch Inch mm Inch (mm) �mm� �F �'C �F PC psi (bar) ;�F C (mm) � ) 'h(127) ,shs(24) '/z"NPT ��,s" 11 155 68 135 57 175 12 100 38 4.9 2.25 57 s 3 �R,�z� � ) � ) � ) hs(4.7) /4 (19) *Baseline flows and pressures for 0.05 density FP Data "A": Max. Sprinkler Sprinkler °°q°° Flow Pressure FP Position Spacing Identification Inch (mm) ft(m) 9pm(Lpm) psi (bar) Number(SIN) Max. Recessed '/,6(11) 12 x 12(3.6x3.6) 13(49) 7.0(0.48) 14 x 14(4.3x4.3) 13(49) 7.0(0.48) Min. Recessed 15/,s(24) 16 x 16(4.9x4.9) 14(53) 8.2(0.56) R3516 Note:Sprinklers shown in Fig.3 and Fig. 4 are not suitable for in- 18 x 18(5.5x5.5) 18(68.1) 13.5(0.93) stallation in ceilings which 20 x 20(6.1x6.1) 20(75.7) 16.7(1.14) have positive pressure in the space above. Technical Data: Fi Res 58 CCP Pendent and Recessed Pendent/FP Sprinkler CCP Assembly Max.Ambient Sprinkler Nominal Orifice Max. Pressure K Thread Size Temp. Rating Temp. Rating Temp. Length Inch Inch (mm) ;tiF wC rF �� psi (bar) �F yC Factor �mm) Yz" NPT(RY2) 'h(13) 155 68 135 57 175(12) 100 38 5.8 2.25(57) `Baseline flows and pressures for 0.05 density Max. Sprinkler Spacing Flow Pressure Sprinkler ldentification ft(m) gpm (Lpm) psi (bar) Number(SIN) 12 x 12(3.6x3.6) 16(61) 7.6(0.53) 14 x 14(4.3x4.3) 16(61) 7.6(0.53) 16 x 16(4.9x4.9) 16(61) 7.6(0.53) R3513 18 x 18(5.5x5.5) 19(72) 10.8(0.75) 20 x 20(6.1 x6.1) 22(83.3) 14.4(1.0) *Calculate for a .10 density but in no case go below the baseline flows & pressures 6. Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Sprinkler Temp. CCP Assembly Max. Ambient Sprinkler Thread Size Nominal Orifice Ratin Temp. Ratin Max. Pressure Temp. K Length Inch (mm) psi (bar) Factor °F °C °F °C °F °C Inch(mm) 3/a" NPT(R3/a) "/s2"(13.5) 155 68 135 57 175(12) 100 38 �6 2.25(57) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max. Sprinkler Spacing Flow Pressure Sprinkler ldentification ft(m) m (L m) si (bar) Number(SIN) 12 x 12(3.6x3.6) 21 7.6(0.53) 14 x 14(4.3x4.3) 21 7.6(0.53) *Calculate for a .10 density but Ill 16 x 16(4.9x4.9) 21 7.6(0.53) R7618 no case go below the baseline flows 18 x 18(5.5x5.5) 22 8.4(0.58) 20 x 20(6.1x6.1) 25 10.8(0.74) & pressures • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 r�� '_ .��... ��� f ..-R` s"�j:. � � � � , � . � y��� � { �� ..��� �'� ... . _' ;� i�� `�-�'� ,r� ,. ,I _, , �� �. F1 Res 44& 58 Recessed HSW/F2 Technical Data: F1 Res 44 HSW& HSW/F2 Escutcheon, F2, Data: Sprinkler Max. Face of Fitting to Nominal Max. Sprinkler Adjustment Thread Temp. Ambient K Type wall Size Orifice Ratin Pressure Tem . Factor Length Inch(mm) Inch mm Inch (mm) �,F �C psi (bar) �F �C Inch (mm) F2 1/2(13) 3/,6-"/,6(4.7- 17.4) 'h"NPT 3�8�10� 155 68 1�5�12� 100 38 4.4 2.45(62) (RYz) 175 79 150 66 *Baseline flows and pressures for 0.05 density Max. Sprinkler A Sprinkler Sprinkler Ceiling-to- Flow Pressure Spacing Temp. Rating Identification ft(m) Deflector i,F��,C� gpm (Lpm) psi (bar) Number(SIN) Inch mm 12 x 12(3.6x3.6) 155(68) 175(79) 12(45.4) 7,5(0.52) 14 x 14(4.3x4.3) 155(68) 175(79) 14(53.0) 10.2(0.71) 16 x 16(4.9x4.9) 4-6 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 18(4.9x5.5) (101-152) 155(68) 175(79) 18(68.1) 16.8(1.16) 18 x 18(5.5x5.5) 155(68) 175(79) 19(72.0) 18.7(1.29) 16 x 20(4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(1.89) R3531 12 x 12(3.6x3.6) 155(68) 175(79) 14(53.0) 10.2(0.71) 14 x 14(4.3x4.3) 155(68) 175(79) 16(60.6) 13.3(0.92) 16 x 16(4.9x4.9) 6- 12 155(68) 175(79) 17(64.4) 15.0(1.04) (152-305) 16 x 18(4.9x5.5) 155(68) 175(79) 20(75.7) 20J(1.43) 16 x 20(4.9x6.1) 155(68) 175(79) 23(87.1) 27.4(1.89) *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. • Model F1 Res 44 SWC � '� r++.,�. 4"to 12' �� [701-60mm To � � �"` � 304.80mm] -.�,� � 1 7�4"[37 75rr�mJ Maximum W.- 7!► �1 � � � Fo�e or Frr,�g �usr+ oN couER, rHErv °��.-�_ � ;� ro woii o�me�s�o� ruRN ra no✓usr uNnt ' `"'��'- � � ncNr Aca�NSr wau- ��.�t�s' i"x i/2°Red��e� � 1� � � _ �� -___ _ � - - l2ecommended 'V" ' ., ' �., . � �`--�� i � "', �� Woll Hole 2 5/16 � i ' I �^ s/e° [sa_�4..�m]�-w;, �--- - — — —H-- 3 s/rs' [66.68mmJ Dla. 'i D�o. i [84.74mm] �J --_ ' � nlb. �I rurzN co«aR uNn� ncHr acaiNSr sPR�NK�ER wRENCr+ eoss " � ���32� [42.o�mm] rssFCO� � 7/2°[izJOmmJ nd��stme�t F1 RES 44 SWC Fig. 5 Technical Data: F1 Res 44 SWC Sprinkler Cover Max. Thread Nominal Temp. Temp. Max. qmbient K Sprinkler Size Orifice Rating Rating Pressure Temp. Factor Length Inch (mm) psi (bar) Inch (mm) �°F wC ;"F ,C wF ;°C Yz" NPT 3/8(10) 155 68 135 57 175(12) 100 38 4.4 2.45(62) �R'�2) *Baseline flows and pressures for 0.05 density Max. "A" Ceiling-to- Flow Pressure Sprinkler Sprinkler Spacing Deflector gpm (Lpm) psi (bar) Identification ft(m) Inch (mm) Number(SIN) 12 x 12(3.6x3.6) 13(49.2) 87(0.60) 14 x 14(4.3x4.3) 14(53.0) 10.2(0.71) 16 x 16(4.9x4.9) (101-52) 1��64.3) 15.0(1.1) 16 x 18(4.9x5.5) 19(71.8) 18.7(1.13) 16 x 20(4.9x6.1) 23(87.1) 27.4(1.89) R3531 12 x 12(3.6x3.6) 14(52.9) 10.2(0.71) 14 x 14(4.3x4.3) 6- 12 15(56.7) 11.7(0.81) 16 x 16(4.9x4.9) (152-305) 18(68.1) 16.8(1.16) 16 x 18(4.9x5.5) 20(75.6) 20.7(1.43) *Calculate for a .10 density but in no case go below the baseline flows & pressures 8. Technical Data: F1 Res 58 HSW& HSW/F2 Sprinkler Max. Escutcheon, F2, Data: Nominal Max. Sprinkler Thread Temp. Ambient K Face of Fitting to Size Orifice Rating Pressure Temp. Factor Length Adjustment Inch (mm) �F oC psi (bar) �F �C Inch(mm) Type Inch(mm) �nch(mm) '/z"NPT 155 68 100 38 F2 Yz(13) 3/,s-"/,s(4.7- 17.4) ��,�2� Yz(13) 175 79 175(12) 150 66 5.8 2.45(62) `Baseline flows and pressures for 0.05 density Max. A Sprinkler Sprinkler Ceiling-to- Flow Pressure Sprinkler Spacing Temp. Rating Identification ft(m) Deflector �F��,C� gpm (Lpm) psi (bar) Number(SIN) Inch(mm) 12 x 12(3.6x3.6) 155(68) 175(79) 16(60.6) 7.6(0.53) 14 x 14(4.3x4.3) 155(68) 175(79) 18(68.2) 9.7(0.67) 16 x 16(4.9x4.9) (101-16 2) 155(68) 175(79) 21 (79.5) 13.2(0.91) 16 x 18(4.9x5.5) 155(68) 175(79) 25(94.7) 18.6(1.28) 16 x 20(4.9x6.1) 155(68) 175(79) 29(109.8) 25(1.73) R3533 12 x 12(3.6x3.6) 155(68) 175(79) 22(83.3) 14.4(1.0) 14 x 14(4.3x4.3) 6_12 155(68) 175(79) 22(83.3) 14.4(1.0) 16 x 16(4.9x4.9) (152-305) 155(68) 175(79) 26(98.4) 20.1 (1.39) 16 x 18(4.9x5.5) 155(68) 175(79) 31 (117.4) 28.6(1.97) *Calculate for a .10 density but in no case go below the baseline flows & pressure 9. Technical Data: F1 Res 58 HSWX (SIN RA3533) Max. Sprinkler Nominal Max. Sprinkler Sprinkler Thread Ambient K Length Orifice Pressure Temp. Rating Identification Size Inch(mm) psi (bar) Temp. Factor Inch Number(SIN) �'F wC �'F �"C (mm) Bulb '����NPT ��z���13) 175(12) 155 68 100 38 5.8 2.45(62) RA3533 (R'/z) 175 79 150 66 *Baseline flows and pressures for 0.05 density Ordinary Temp. Rating Intermediate Temp. (155i°F/68wC) Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (175NF/79�'C) Ft x Ft(m x m) Ft(m) Flow to Ceiling Spacing Flow Pressure GPM (V Pressure Inch (mm) Ft(m) GPM(Vmin) PSI (bar) m�n� PSI (bar) 18 x 20(5,5 x 6,1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) 33(125) 32.4(2,23) 1/z(13)recessed � using F2 escutcheon 16 x 24(4,9 x 7,3) i 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) 35(133) 36.4(2,5) 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 38(144) 42.9(2,96) 6 to 12(152 to 305); � Yz(13)recessed 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) � 14(4,3) 46(174) 62.9(4,34) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model F1 Res 58 HSWX (Bulb) � ' .r R, FacE oF FirnNC ro �� WALL DIMENSION ' � -� 7 7 J�76'" MIN. � ,� - _����,r,�� � [31.Smm] ._ L' 1�4" HOLE D1,4. � ��„ q° - - (57.2mm] CE/LING TO (32mm) DEFLECTOR 7'"X 1�2° REDUCER DIMENSION 4��� � a - � ,„. � - �� - f i�iiiiiii 'i ��� � i � i ii 7 75�16° DIA. /�iii��' I . 49.2mrn �i�iii ( .� � �� 2 27�32" D/A. I � In�i� 'i 71mm,7 �'-i' - �'-�"� • Model KRes58 HSWX (Link) ; �_,'— �' � �-- -- ��� rukN co�ca� uNn� nc,vr aca�NSr sPR�NK�ER � iNRENCH BOSS. � 7�2°(13mm) � i35FGO8 ADJU�TMEM� F1 RES 58 HSWX � � Fi 6 �, � _. g� _:,� - ,,�� 10. Technical Data: KRes58 HSWX (RA3593) Nominal Max. Max. Sprinkler Sprinkler Thread Orifice Pressure Ambient K Length Identification Size �nch(mm) psi (bar) Tem . Factor Inch Number(SIN) wF wC (mm) Link ��� NPT �/z" (13) 175(12) 100 38 5.8 2.45(62) RA3593 �R'�2) *Baseline flows and pressures for 0.05 density Ordinary Temp. Rating Top of Deflector Minimum Max.Coverage area Max. Spacing (165r Fl74wC) Ft x Ft(m x m) Ft(m) Flow Pressure to Ceiling Spacing GPM(Vmin) PSI (bar) Inch (mm) Ft(m) 18 x 20(5,5 x 6,1) 18(5,5) 29(109) 25(1,72) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8(1,85) � 4 to 6(100 to 152); 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4(2,23) �/2(13)recessed using F2 escutcheon 16 x 24(4,9 x 7,3) 16(4,9) 38(144) 42.9(2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4(3,75) 8(2,4) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4(2,5) � 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9(2,96) 6 to 12(152 to 305); Yz(13)Recessed 16 x 24(4,9 x 7,3) 16(4,9) 42(160) 52.4(3,6) using F2 escutcheon 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9(4,34) For Ceiling types refer to NFPA 13, 13R or 13D �Calculate for a 0.10 density but in no case go below the baseline floor and pressures. Maintenance Model F1 Res 30, 49, F1 Res 58 & F1 Res 76 Sprin- manufacturer's installation guidelines and the appli- klers should be inspected and the sprinkler system cable installation standard. Where pendent residential maintained in accordance with NFPA 25, 13, 13D, and sprinklers are installed under sloped ceilings having 13R. Do not clean sprinkler with soap and water, Am- a pitch from [4/12] to [8/12], the sprinklers shall be monia or any other cleaning fluids. Remove dust by listed for such use. Deflector-to-ceiling distance list- using a soft brush or gentle vacuuming. Remove any ing shall be 1" to 8" maximum. Sprinkler frame and de- sprinkler which has been painted (other than factory flector shall be of bronze frame construction having a applied)or damaged in any way. A stock of spare sprin- '/2" NPT thread. Water seal assembly shall consist of a klers should be maintained to allow quick replacement Teflon� coated Belleville spring washer with top-loaded � of damaged or operated sprinklers. Prior to installation, extruded or cold head cup with 3 mm glass bulb con- sprinklers should remain in the original cartons and taining no plastic parts, and having a temperature rat- packaging until used. This will minimize the potential ing of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall for damage to sprinklers that could cause improper op- have a nominal K-factor of 4.9 & 5.8. Standard finish: eration or non-operation. [Bronze] [Chrome-plated] [White Polyester] [Special Model F1 Res 30, 49 & 58 Pendent Sprinkler finish-specify]. Fiesidential pendent sprinklers shall be S ecifications Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 p (Bulletin 135). Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the � "DuPont Registered Trademark 11. Model F1 Res 30,49&58 Recessed Pendent/F1, Model Fi Res 30,49&58 Recessed Pendent/F2, plate adjustment. Cover plate temperature rating shall be Model F1 Res 30,49&58 Recessed Pendent/FP 135°F (57°C). A plastic protective cap shall be provided Sprinklers shall be [cULus Listed] [New York City MEA and factory installed inside the sprinkler cup to protect Approved (258-93-E)] low flow residential recessed pen- the sprinkler from damage, which could occur during dent sprinklers engineered to provide a minimum design construction before the cover plate is installed. Standard density of 0.10 gpm/ftz over the listed coverage area. cover plate finish: [White] [Custom Color—specify]. ]. Con- Listed flows as specified by the manufacturer's technical cealed pendent sprinklers shall be Reliable Model F1 Res data sheets are to be used. Residential sprinklers shall 49&58 CCP, SIN R3516&R3513(Bulletin 135). be installed in conformance with the manufacturer's instal- Model F1 Res 44, F1 Res 58 Horizontal lation guidelines and the applicable installation standard. Sidewall, F1 Res 58 HSWX & KRes58 HSWX Where pendent residential sprinklers are installed under Residential Sprinkler Specifications sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling Sprinklers shall be [cULus Listed] low flow residen- distance listing shall be 1"to 8" maximum. Sprinkler frame tial horizontal sidewall sprinklers engineered to pro- and deflector shall be of bronze frame construction hav- vide a minimum design density of 0.10 gpm/ft2 over ing a'/2" NPT thread. Water seal assembly shall consist of the listed coverage area. Listed flows as specified a Teflon* coated Belleville spring washer with top-loaded by the manufacturer's technical data sheets are to be � extruded or cold head cup with 3 mm glass bulb contain- used. Residential sprinklers shall be installed in con- ing no plastic parts, and having a temperature rating of formance with the manufacturer's installation guide- [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a lines and the applicable installation standard. Where nominal K-factor of 4.9 (70). Standard finish: [Bronze] horizontal sidewall residential sprinklers are installed [Chrome-plated] [White Polyester] [Special finish— spec- under sloped ceilings having a pitch from [4/12] to ify]. Recessed escutcheon assembly shall be a steel, L8/12],the sprinklers shall be listed for such use. Sprin- two-piece escutcheon [with '/2" adjustment (Model F2)] kler frame and deflector shall be of bronze frame con- [with 3/4" adjustment (Model F1)] [of push-on and thread struction having a '/z" NPT thread. Water seal assem- off design with'/2° adjustment(Model FP)]. Standard finish bly shall consist of a Teflon-coated Belleville spring shall be [brass][bright chrome] [white painted]. Residen- `�`�asher with top-loaded extruded or cold head cup tial recessed pendent sprinklers shall be Reliable [Model With 3 mm glass bulb containing no plastic parts, and F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res having a temperature rating of [155°F (68°C)] [175°F 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 ��g°C)]. The solder element (Link) version, the water Recessed Pendent/FP]SIN R3516&R3513(Bulletin 135). seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed Model F1 Res 30, 49 & 58 CCP Pendent assembly forthe HSWX (Bulb & Link) should be a steel (Concealed) two pieces escutcheon with 1/2" adjustment (Model Sprinklers shall be [cULus Listed] [New York City MEA F2) standard finish should be Bright Chrome and white Approved (258-93-E)] low flow residential concealed painted. The F1 Res 58 HSW is also available with low sprinklers engineered to provide a minimum design den- lead frame. F1 Res 58 HSW and HSWX sprinklers shall sity of 0.10 gpm/ft2 over the listed coverage area. Listed have a nominal K Factor of 5.8 and F1 Res 44 a nomi- flows as specified by the manufacturer's technical data nal K factor of 4.4. Standard finish: [Bronze] [Chrome- sheets are to be used. Residential sprinklers shall be in- plated] [White Polyester] [Special finish— specify]. stalled in conformance with the manufacturer's installa- Residential horizontal sidewall sprinklers shall be Reli- tion guidelines and the applicable installation standard. able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Where pendent residential sprinklers are installed under Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 sloped ceilings having a pitch from [4/12] to [8/12], the (Bulletin 135). sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a '/2" NPT thread. Water seal assembly shall consist of a � Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a '/2" cover � "DuPont Registered Trademark 12. Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Residential recessed pendent sprinklers shall be Reliable Use description for the Model F1 Res 58 horizontal [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res sidewall sprinkler with the following modifications: Re- 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed place "horizontal sidewall sprinkler" with "recessed hori- Pendent/FP] SIN R7618 (Bulletin 135). zontal sprinkler." Add: Fiecessed escutcheon assembly Model F1 Res 76 CCP Pendent (Concealed) shall be a steel, two-piece escutcheon with '/2" adjust- Sprinklers shall be [cULus Listed] low flow residential ment (Model F2). Standard finish shall be [brass][bright concealed sprinklers engineered to provide a minimum chrome] [white painted] [Special finish— specify]. Resi- design density of 0.10 gpm/ft2 over the listed coverage dential recessed horizontal sidewall sprinklers shall be area. Listed flows as specified by the manufacturer's Reliable Model F1 Res 58/F2, SIN R3513(Bulletin 135). technical data sheets are to be used. Residential sprin- Model F1 Res 76 Pendent klers shall be installed in contormance with the manufac- Sprinklers shall be [cULus Listed] low flow resi- turer's installation guidelines and the applicable installa- dential pendent sprinklers engineered to provide a tion standard. Sprinkler frame and deflector shall be of minimum design density of 0.10 gpm/ft2 over the list- bronze frame construction having a 3/4" NPT thread. Water ed coverage area. Listed flows as specified by the seal assembly shall consist of a Teflon-coated Belleville manufacturer's technical data sheets are to be used. spring washer with machined or cold head cup with 3 Residential sprinklers shall be installed in conformance mm glass bulb containing no plastic parts, and having a with the manufacturer's installation guidelines and the temperature rating of 155°F (68°C). Cover plate assem- applicable installation standard. Sprinkler frame and bly shall consist of a brass cover plate and copper alloy deflector shall be of bronze frame construction having retainer flange. Method of attaching the cover plate to the a 3/4" NPT thread. Water seal assembly shall consist of sprinkler cup shall be a push-on and thread-off design a Teflon-coated Belleville spring washer with machined allowing a '/2" cover plate adjustment. Cover plate tem- or cold head cup with 3 mm glass bulb containing no perature rating shall be 135°F (57°C). A plastic protec- plastic parts, and having a temperature rating of[155°F tive cap shall be provided and factory installed inside the (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal sprinkler cup to protect the sprinkler from damage, which K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- could occur during construction before the cover plate ed] [White Polyester] [Special finish—specify]. Residen- is installed. Standard cover plate finish: [White] [Custom tial pendent sprinklers shall be Reliable Model F1 Res Color—specify]. ]. Concealed pendent sprinklers shall be 76, SIN R7618 (Bulletin 135). Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Finishes�'> Model F1 Res 76 Recessed Pendent/F2, Standard Finishes Model F1 Res 76 Recessed Pendent/FP Sprinkler F1, F2, FP Escutcheons Sprinklers shall be [cULus Listed] low flow residen- BronZe Brass tial recessed pendent sprinklers engineered to provide cnrome Piated Bright Chrome Plated a minimum design density of 0.10 gpm/ft2 over the listed White Polyester Coated�?� White Painted � coverage area. Listed flows as specified by the manu- Special Application Finishes facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the Sprinkler F1,F2,FP Escutcheons manufacturer's installation guidelines and the applicable Eie�troiess N��kei Electroless Nickel installation standard. Sprinkler frame and deflector shall PTFE(refion��•�z� PTFE�Tefion��� Bright Brass Bright Brass be of bronze frame construction having a 3/4" NPT thread. B�ack P�ated Black Plated Water seal assembly shall consist of a Teflon-coated Bel- Biack Pa�nt Black Paint leville spring washer with machined or cold head cup with oft wn�te oft wn�te 3 mm glass bulb containing no plastic parts, and having Chrome Dull Chrome Dull a temperature rating Of [155°F (68°C)] [175°F (79°C�]. "�Other finishes and colors are available on special order. S rinklers shall have a nominal K-factor of 7.6. Standard 7 Consult factory for details. I p cULus listed Corrosion Resistant. finish:[Bronze][Chrome-plated][White Polyester][Special finish—specify]. Recessed escutcheon assembly shall be Information a steel, two-piece escutcheon [with '/2° adjustment (Mod- Specify:Ordering el F2)] [with 3/4° adjustment (Model F1)] [of push-on and 1. Sprinkler Model thread off design with '/2" adjustment (Model FP)]. Stan- 2. SprinklerType dard finish shall be[brass][bright chrome] [white painted]. 3. Temperature Rating 4. Sprinkler Finish I "DuPont Registered Trademark 5. ESCUtCheOn FlniSh 13. Rel iable . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and properry for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co.,IIIC. Recycled � d (800)431-1588 Sales Offices Paper � '� � (800)848-6051 Sales Fax (914)829-2042 Corporate OffiCes Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in u.s a.oi/i4 P/N 9999970322