HomeMy WebLinkAboutB13-0477 REV6 plumbing plan GENERAL NOTES: SHEET DETAIL NOTES: V o � � P L U M B I N G F I X T U R E C O N N E C T I O N S C H E D U L E Z W � � 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND 1 O CONNECT%" CW TO SD. INSTALL BACKFLOW PREVENTER PRIOR TO UNIT COLD HOT ~ ^ ^ STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE CONNECTION WITH SD.ADD VALVE TO ALLOW DRAINAGE DURING MANUFACTURER& MODEL NO DESCRIPTION WASTE VENT REMARKS Z G C STRUCTURAL ENGINEER. WINTERIZATION. (MATCH EXISTING CONCESSION ASSEMBLY). TAG WATER WATER �� o � � CONTRACTOR TO VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION. SD SODA DISPENSER 1-1/2" - 1/2" - INSTALL BACKFLOW PREVENTER-ZURN WILKINS 740-OR SIMILAR. INDIRECT WASTE ROUTED TO FLOOR SINK W U W O�p 2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE � Z �,,, O � A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 2O CONNECT 1 �" IW TO DRAIN PAN FOR ICE WELL AND SD. W� PLUMBING FIXTURE SPECIFICATIONS&HARDWARE WATER CLOSEf 3" 2" 1/2" - RE-USE FIXTURES FROM DEtvtOLISHED RESTROOM IN BOX OFFICE � Z � � � � S E L E C T I O N T O B E B Y T H E G E N E R A L C O N T R A C T O R. ` ^ 3. ALL WASTE PIPING SHOWN DASHED SHALL BE LOCATED BELOW THE � �� LV LAVATORY 1-1/2" 1-1/2" 1/2" 1/2" Q O3 ROUTE 1 / IW FROM EACH ICE WELL TO FS AND TERMINATE WITH AIR FIXTUREALLOWANCENOTTOIXCEEDTHE V J H � ,� 0 F L O O R D E C K. G A P. C O N N E C T 2"W& 1 %2"V T O F S. E S T A B L I S H m B U D G E f. a "� E � — DF DRINKING FOUNTAIN 1-1/2" 1-1/2" 1/2" - O � V � p 4. CONFIRM EXISTING PIPE LOCATIONS IN FIELD PRIOR TO STARTING WORK. 4 O CONNE CT 2"W& 1 %" COMMON VENT TO FD. FS FLOOR SINK 2" 1-1/2" - - - V� � ¢ � U � 5. INSTALL CLEANOUTS PER SECTION 708 OF THE 2012 IPC. O5 CONNECT 2"V TO EXISTING 2"OR LARGER VENT PIPE. RD ZURN Z110 ROOF DRAIN IW - - - CONNECT 3" INDIRECT WASTE � � a � � � 6. INSTALL HAMMER ARRESTOR DOWNSTREAM OF FURTHEST WC FD ZURN Z4156 2"FLOOR DRAIN 2" 1-1/2" - - PROVIDE PROSEf TR,4PGUARD W V V -e M J O6 EXISTING 4"W LOCATION, VERIFY IN FIELD.VERIFY FLOW DIRECTION AND � ~ cn � m � V � CONNECTION. FUNCTIONALITY PRIOR TO CONNECTING NEW PIPE. � CO ZURN ZN1400 CLEAN OUT VARIES - - - - Z U Z W .� j Z V O7 EXISTING 1" CW ENTRY. VERIFY LOCATION AND SIZE IN FIELD. CONNECT WCO ZURN Z1441 WALL CLEAN OUT VARIES - - - - �C Q M � O Q p� � Q J N N � NEW 1 Ya" CW LINE WITH SHUT-OFF VALVE AND AIR HOSE CONNECTION AS COTG ZURN Z1400 CLFAN OUTTO GRADE VARIES - - - LOCATE WffHIN 5'OF THE BUILDING V U W U CLOSE AS POSSIBLE TO EXISTING 1"CW ENTRY LOCATION. � W W J W 8 CONNECT�" CW,%Z" HW, 1 %2"W& 1 %Z"V TO LV. � a W a O� „ „ „ EXH AU ST FAN SC H E D U L E OR EQUIVALENT N 9 CONNECT 1 CW, 3 W&2 V TO WC. ELECTRICAL DATA NOISE p � p�p � � UNIT MANUFACTURER& TOTAL FAN OPER. �''� � O M � 10 CONTINUE�" HW TO EXISTING WATER HEATER AND CONNECT TO SERVICE LOCATION TYPE ESP(IN) LEVEL REMARKS � � � M ^ TAG MODEL NO. CFM RPM POWER V/PH/Hz WT.(LBS) EXISTING HW DISTRIBUTION PIPING. (SONES) � � � N � PANASONIC UNISEX/ADAFAMILY INTEGRAL BACKDRAFT DAMPER, INTERLOCK WITH OCCUPANCYSENSOR.FAN TOACTIVATE AFTER N� � � � 11 CONNECT%" CW, 1 %2"W& 1 %2'V TO DF. EF-1 SEE PLAN CEILING 65 1,089 0.25 14.5 W 120/1 /60 0.4 10.4 � — FV-08VQ5 RESTROOM 1 MINUTE OF SUSTAINED OCCUPATION AND REMAIN ON FOR 10 MINUTES. '� V O O O pp O� O� O� 12 CONNECT 1 �"V TO EXISTING 2" OR LARGER VENT PIPE. Y O 1 3 I N S T A L L E F-1 I N E A C H R E S T R O O M A N D I N T E R L O C K W I T H O C C U P A N C Y � � a � O ' SENSOR. AFTER 1 MINUTE OF SUSTAINED OCCUPATION,TURN FAN ON, U �p � AND REMAIN ON FOR 10 MINUTES. UPSIZE TO 6"Q1 DUCT AT JUNCTION > � Q AND TERMINATE IN WEST WALL WITH 6"WALL CAP. I■■I■■I a�i � � mo�+ (� w N � Z � o � � W � � a' � W z W Z J Z zU � Q zW � O W W � p� > a � O uQ � � SEAL �r�-yZ4L��ttr�frl'��,. u`�''{G'sj Kt'� -�t��'' H°,2? ' _ � 4 � � �P �i � I I y' '� .,� .,..,.��5 E . � }�: � � � � i�,, f`L.,ln.ue3irnx°}' I I I _ _ — _ _ — _ _ — _ _ � _ _ _ _ ----�T-----� � - - - - - - - - - - - - - i ii iii � `� ,' � � ii i ii i � i � �� N � � ii � � � � � � i ,��� ii ii � � i ii iiii � � ii � � ii i i � - - - - �- L - � � i i � � - - - - - - - � � � � � " � i � ii � � � ii � ii Z REMOVE (6) EXISTING DRINKING FOUNTAINS AND INSTALL(3) � � � I � � � NEW DRINKING FOUNTAINS ACCORDING TO ARCHITECT PLANS. � I � � I I . I� � W RE-USE WATER AND WASTE CONNECTIONS WHERE POSSIBLE 0 � � II _ _ _ _ _ _ _ _ _ _ JI. AND CAP ANY UN-USED WATER AND WASTE STUBS. � L _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � � � � — � _ � n N.I.C. I � - - - - � � I L - - — - - J � ~ I I :.�. ,. � � \ / � � I — - - - - - � � � � �, � — �., \ / � � � N.LC. O " ' I I j� I I � � I I O p I I � � � � � / � H � � � � Q � � � N.I.C. � � � � / � � � � I I ADD VALVE AT DRINKING FOUNTAINS TO ALLOW DRAINAGE DURING �I 'T y � I � Q � I I WINTERIZATION. (MATCH EAST RESTROOM ASSEMBLY). CONTRACTOR � I 0 � � � � — I � � � TO VERIFY WITH MANUFACTURER PRIOR TO INSTALLATION. • O� � � I I � - - - - - �� — I � � � I � I � _ � J N � ,� � � ; L - - - - - - - ,�� � � � ,��, - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � � , , � - - - - � r - - -, � � J N I _ � - - - — L — � U � � - - - - - - - - J � I�y O - - - - - - - - - � i — Q I I MENS WOMENS I I ' � � � - - - � RESTROOM RESTROOM I I � > �� / 114 113 � O �o / � W �� I I � ,:� � N.I.C. — — — — — _ � � � � � � � � � � � i � � - - - - - - - - - - � I I I � '� � '� � � - - - - - - N.I.C. �\ /� � � � � � � ` � � /\ I � � � � � e — — — — — — � � � I� d _ � r4° cw � 0 L.L I � � /---� �- - - - -11 - - � � jESSION � � � �� I I II - - - - - - - - - - - - - - - - - - O � � � `{� ISSUED FOR: �- I ------- ----- ��_.�f — — — — � No. DATE COMMENT UNISE"� ° D�� � I � - - - - - - - - - - - - - - - - - - - - - J O O C 9/17J13 ortsMiHacexr�u�nori RESTRG s� C04 5 �� 12 I (' 10/16/13 PERMRSET � O 1 %4 CW O '^'�RK RM/ I E 11/6/13 FORCONSTRUCfION F 11/2W13 CHANCES TO PLANS � � I >F F I C E I� — �I G t s/t s/t s coNSixucnoN I — — �Y cw I � — � - - -�� - - -�� � 10 � ' � �� N.I.C. 116 i \\// I � v v x 1 CW v v I - � /\ N.I.C. WCO9 � Q � �" HW � LVO8 O I � I � / \ � I �o SD O 4 j w O � I IL — � N.I.C. N.I.C. 6"Q) EXHAUST CAP N � � � �� B O 1 � � � � : , � 3" IW UP TO RD. � � � � I � I FS O ' II 4"Q1 EX � " .J+ I / I 3" IW TO CONTINUE TO EXISTING �C � � — — — � — — / II - - - - - - - J STORM DRAINAGE. �I-I 3"W - - "r �� —3"W — I I� \� I \� FD 4 WC 9 �� � � I 1 %z" �W e ,' II \\�\ —O 7 � � „ � I \ 1 /z w � I � � � EF I � O 1 %z°V �(' � �I �\� ' N.I.C. N.I.C. I N S T A L L H A M M E R A R R E S T O R � 1 3 ,I, � I � N.I.C. IN CW PIPE, DOWNSTREAM OF LV 8 c'�-� � I S�O " � � � I I� ��� �g O C� WC CONNECTION. O � I � � I � ��� N.I.C. KEY PLAN — -� r� _ � I � � I � 1 1 8 � I / � � �V �� +-� '� (�( �� D F 11 D F 11 � � � � "U" `�' "��" —O —O � � � \ N.I.C. I I � I I I � � � �\ �� � - - - - - - - - - �—� - - - - - - - - - - - - - �� � � � � � ALL PLUMBING SHALL BE PROPERLY DRAINED AND I � \ �� WINTERIZED TO AVOID FREEZING DURING WINTER MONTHS. � \ ADD VALVES AT FURTHEST FIXTURES IF NECESSARY TO MATCH I � \ ` � \\ EAST RESTROOM ASSEMBLIES. I � \\ I I ` ��\\ / � - - - - - - - - - - - - - �-� - � - - - - - - - - - i � � . . _ - - - - -� - - - -, NORTH � PLUMBING PLUMBING PLAN P LAN SCALE: 1/4"= 1'0" PROJECT No. ORICIN DATE 20132266.00 07/01/13 DRAWN BY CHK BY TRV BY KBW TOC SHEET No. P2 . 0 SCALE: y" = 1�