HomeMy WebLinkAboutB14-0049 Comm Check C�Mcheck Software Version 3.9.2 Interior Lighting Gampliance Certificate 2012 1ECG Section 1; Project Enformation Project Type: A14eration Praject Title : Manor Vail L.odge-Meetirrg Rooms Constructian Site: OwnerlAgent: DesignerlContractor: Uail,CO 81657 Chuck Langston AEC 4�801 US Hwy 6&24 5uite 294 Avon,CO 81620 97€}-74$-$520 charles@aec-vail.cam Sectiorr 2: �nterior Lighting and Power Calculatian A B C D Area Category Floor Area Allowed AlEowed Watts (ft2) Wat�s 1 fk2 (B x C) DininglMeeting Room(Hot�I:Dining area) 6691 3.3 6698 Taial Allawed Watts= 6698 5ection 3: Interior Lighting Fixture Schedule A B C D E Fixfure ID :Oescription!Lamp I Wattage Per Lamp!Ballast �amps! #of Fixfuee (C X D} Fixture Fixfures Watf. DirringlM�et'sng Rooan(Hatel:Dining area 6691 sq.ft.) LED:A:2X2 Grid:Other: 3 71 49 3479 Halogen:B:Recessed Adj MR96: 12V Halogen 75W: 1 11 75 825 LED:C1:Chsndelier:Okher. 2 7 44 308 LED:C2:Chandelier:Qther: 2 6 44 264 LED:C3:Ghandelier:Other: 3 7 66 462 LED:C4:Chandelier:Othar: 4 5 88 44� LED:D:Recessed Downlight 6°':Other: 1 78 13.5 1�53 LED:W:Wall Sconce:Other: 2 17 7 119 Total Psoposed Watts= 6950 Section 4: Requirements Checklist Lighting Wattage: ❑ 1. "fptal proposed watts must be less than or equal io iota3 allowed watts. Allawed W�ttage:8698 Proposed Wattage:695D Complies:YES Mandatory Requiremenfs: � 2. Dwellir�g units(completa independeni Eiving facilities)witt�in commercial buildings are not required to comply with irrterior lighting requirements of this code provided ihat�=75 percent of the permanently installed fixtures oth�r than law valtage fighting contain only high efficacy lamps. � 3. Manual Controls: Each enclosed space has manual lighting ca�teol.Ftemotely iocated manual coc�trols are la�elled for area oi service and indicat�anloff status. Exception{sJ: � Securitylernergency areas with 24-hour operation. Project Titfe: Manor Vail Lodge-Meeting Raoms Report dafe: 03117/14 Data fijename:P:1Current Projects114021.Ofl-Manor Vaif Conference�toom RemodeRCalculationslCOMcheck11402i-Comcheck.cck Page 1 of 0 Siairways/corridors iha�are means of egreas. � 4. Ligh#Reduction Controls:Each space required to have a manual conirol aiso allows for reducing tha cannected lighting load by at least 50 gercent by either controlling all luminaires,dual swiiching of altemai�rows of lurninaires,alternate luminaires,or alternate lamps, switch?ng ihe middle lamp luminaires independenfly of oth�r larnps,or switching each]uminaire or each la�np. Exception(sJ: ❑ Only one luminaire(lamp<10�1 W}in space. � An occupant-sensing device controls the area. � The area is a corridor,equipmenUstore rooms, restrooms, public lobby,elec.lmech.room, or sleeping unit. � Areas that us�<0.6 Wattslsq.fi. � Daylight spaces having ar�tomatic daylighcing controls. � 5. Automatic time switching controls are inslafled and have an override switching device.The override switching device allows for�=2 hour operation cycle withVn sp�ces�=500Q sq.fi.,manu�l operation,and is readily accessibla and l'ocated where the apeeation of the cor�nected leghts are visible or communicated to the switc�. Excepfion(s): 0 Sleeping units,patient care areas;and spaces wher�automatic shutoff would endanger saPety or security or where lighting is intended for 24-hour operation. � Emergency�gress tighting. 0 Spaces where lighting is controlled with occupeney sensors. ❑ Malis,arcades,audiioriums,single tenant retaiG spaces, industrial facilities�nd arenas that are<=20,000 sq.ft.are permitted exceed the 2-haur operation cycle limit when a captive key deuice override switch is installed. � 6. dccupant sens4rs are install�d in the following spaces and aukomatieally turn lighting off within 30 minutes of all occupants lea�ing khe space:Classrooms, conferencelmeetin�/training rooms,emp9oyee lunch and break raoms,private affices,siorageljanitorial rooms, restrooms,and other spaces<=300 sq.ft.Automatic-on sensors set power on <50 percent power. Excspfion(sJ: [] Full power automatic-crn controls are permdtted where manual�on operation would endanger the safety or security ot the room ar building oceupants. � 7. Daylight zones have either individual lighting controts cndependent from that of#he general area lighting that are either ma�ual or automatic and serve zones<=2,500 sq.ft.Zones under skylights more than 15 feet from the perimeter have lighting controls separate fram daylight zones adjacent to vertical fenestration, Exception(s): � Contiguous daylight zoraes spanning no more than two arientations are allowed to be controlled by a single controlling de�ice. [] �aylight spaces enc9osed by walls or cailing height partitions and containing two or fewer fight fixtures are not required to heve a separate switch for ger�era�area Iighting. � 8. Automakic dayfight zone Gontrols are capable af reducing power to�35 percent using contirruous dimmirrg ballasts and daylight-sensing conirols OR,are capatrle of automatie power raduation using step-dimming multi-level switching and daylfght-sensing controls having at least two control channels per zane and at least one control step in the 50-70 percent range and another�=35 �percenf af design pawer. � 9. fvledieal task lighting or ar[Ihistory display lighting claimed to be�xempt from compliance has a control device independent af the control of the nonexempt lighting. 0 10. 5eparate confrol device for displaylaccent lighting,case lighting,tasic lighting,nanvisual lighting,urrder-shelflcabinent lighting,lighting for sale,and demeanstration lighting. 0 11. Hotellrraotel sleeping uniis and guest suites!have control device(s)at the entry door ihai controi all permanent luminaires and switched receptacles. � 12. Exii signs 5 Watts or less per sign. 0 13.Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp batlasts). ExceptioR(s): � Electronic high-frequency ballasts. ❑ Luminaires not on same switch. � Recessed luminaires 1 Q ft.apart ar surFacelpendant not continuous. � Luminaires on emergency circuiis. Section 5: Compliance Statement GampGance 5tatement: The proposed lighting alteration project represented in this document is consistent with the building pEans„ specifications and other calculations submitted with this permik application.The proposed ligh#ing alteration project has been designed ta meet the�012 fECC,Chapter S, requirements in COMcheck Version 3.9.2 and ko comply with the mandatory requirements in ihe Requirements Checklist. - � � �' � ' � � � � � � �__ ti�� '� L --yS�,n - �,r ' / 'l �� � Froject Title: Manor Vail Lodge-Meeting Rooms Rep�rt date: 03I17114 Data filename:P:ICurrent Projects114021.40-Manor Vail Conference Room RernodellCalculatdonslCONfcheck114021-Comcheck.cck Page 2 of Name-Title Signature Date Projeci Tiile: Manor Vail Lodge-Meeting Rooms Report date: 03117/14 Dafa filen�me: P:1Current Proj�cts114029.00-Ar�anor Vail Conference Room R�modellCalculationslCQMcheck114021-Comcheck.cck Page 3 of