Loading...
HomeMy WebLinkAboutA14-0009 Data Sheets Honeywell VISTA°-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL — i � � ��� � , �t, � �� . , � ° �� :_�,. --- ,.��' �`.. , �' �.�� Now UL864 9th Edition Approved The new VISTA-128FBP provides the ultimate protection of initiating devices, notification circuits, communication devices, life and property.This UL Listed commercial fire and burglary keypads, RF receivers and relays are also supported. The control panel supports up to eight partitions and up to 128 VISTA-128FBP has been designed to mount quickly and zones/points using hardwired, wireless and V-Plex° easily in an attack resistant cabinet, and is available in 12V addressable technologies. A diverse line of Honeywell and 24V models. FEATURES • Eight hardwired zones standard, • Supports V-Plex addressable • Supports Internet and GSM expandable to 120 V-Plex VISTAKEY access control alarm reporting� addressable points/zones or (1 to 8 doors) • Supports graphical user interfaces 128 wireless points/zones .Two on-board notification (bell) for burglary use • Can control eight separate areas circuits delivering 2.3A @ 12V . Supports 6160CR-2 multi-LED independently(8 partitions) •Automatic smoke detector sensitivity fire keypad • Supports commercial wireless fire maintenance testing . Listed to UL864 9th Edition and burglary devices • Four-wire smoke reset using . Upload/download via Ethernet` • Stores up to 512 events onboard J2 output trigger • Carbon monoxide (CO) •Accommodates 150 user codes • Supports Dynamic Signaling for zone support and up to 250 access card holders AlarmNet Communicators using VISTAKEY�' � When used with AlarmNet devices. VISTA°-128FBPN128FBP-24 Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Notification Appliance Circuits(two): -Individually assignable to any of - Eight zone-Class B expander module eight partitions - Programmable - Single-zone supervised contact module -Up to 16 two-wire smoke detectors each -Temporal code compliant • UL Listed wireless expansion on zone one and two(32 total) - Individually silenceable - Supports up to 128 wireless zones/points -Up to 50 two-wire glassbreak detectors • Programmable on-board auxiliary relay on zone eight - Supervised by control for check-in signals • False alarm reduction features: • Patented addressable V-Plex polling -Tamper protection for transmitters - Exit error logic loop technology - Individually assignable up to eight partitions - Exit delay reset - Supports 120 two-wire zones points - Supports commercial wireless smoke -Cross zoning - Global polling technology for faster detectors processing • Up to eight doors using VISTAKEY V-Plex -Call waiting defeat - Supervised by panel Access Control - Recent close report -Zones individually assignable to • Event reporting • Supports commercial hardwired, partitions, notification circuit(bell)output addressable V-Plex�' ollin loo and • Local printer for event log printing P g P or auxiliary relay wireless zones •Communication - 4,000 ft.capability without the use of • Hardwired zones shielded cable - Phone line, GSM and IP communicator - Provides ei ht st le B hardwired zones support 9 Y - Extender/Isolation bus modules -EOLR su ervised for Fire and UL bur la - Panel operation during download p 9 ry - Eight zone-Class A and B expander installations-Supports N.O.or N.0 sensors module Honeywell SPECIFICATIONS Applications Main Dialer Agency Listings The VISTA-128FBP control is well suited • Line seize: Double Pole • UL609 Grade A Local Mercantile for a variety of applications as an Premises and Mercantile Safe and Vault • Ringer equiv: 0.7B integrated fire and burglary control. Some of the applications supported are: • Formats: ADEMCO�Low Speed, • UL611/1610 Grades A, AA, Central medical and professional buildings, ADEMCO 4+2 Express, ADEMCO High Station churches or synagogues, office buildings, Speed, ADEMCO Contact ID, Sescoa • UL365 Grades A, AA Police Connect schools, strip malls, larger residences and Radionics • UL864/NFPA72 Local, Central and factory or warehouse environments. gackup Communication Station and Remote Station Electrical • Dual phone line capability using • UL985 • Primary power: 18VAC @ 72VA 5140DLM module • Factory Mutual Honeywell No. 1451 •AlarmNet"GSM, i-GSM and IP • California State Fire Marshal • Control panel quiescent current draw: Communicators 300mA • MEA Cabinet Dimensions • Backup battery: • CAN/ULC S304—Central and • 18" Hx14.5"Wx4.3"D Monitoring Station Burglar Alarm Unit - 12VDC, 12AH min to 34.4AH max Environmental • CAN/ULC S527—Central Unit for Fire - Lead acid battery(gel type) . Storage temp: 14° F to 158° F Alarm Systems •Alarm power: 12VDC, 1.7A max for (-10° C to 70° C) each notification (bell) circuit output • CAN/ULC S303—Local Burglar • Operating temp: 32° F to 122° F Alarm Unit Total 2.3A 12V (0° C to 50° C) • CAN/ULC S525—Audible Signal •Aux. standby pwr: 12VDC, 1A max . Humidity: 85% RH Appliances •Total power: 2.3A at 12VDC . EMI: Meets or exceeds the following • Standby time: 24 hours with 1A requirements: standby load using 34.4AH battery - FCC Part 15, Class B Device • Fusing: Battery input, aux. and - FCC Part 68 notification (bell) circuit outputs are protected using PTC circuit protectors. - IEC EMC Directive All outputs are power limited. • Optional 24-volt kit VISTA°-128FBPN128FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices •4208SNF Class A/B Expander Module • 5806W3 - Photoelectric Smoke • 6160CR-2 - Red Fire Keypad •4190SN Remote Point Module- Detector • 6160- Burglary Keypad two zones • 5809 -Wireless Heat Detector • 4204- Relay Module,four form •4193SN and 4193SNP Two-zone • 5817CB -Wireless Commercial C contacts Expander Modules Transmitter • 4204CF-Two supervised output V-Plex Extender/Isolation Modules • 5869 - Hold-Up Transmitter circuits •4297 Extender/Isolator Module • 5881 ENHC- RF Receiver • 5881 Series RF receiver •VSI Isolator Module • 5883H - RF Receiver • 5883H RF receiver V-Plex Smoke Detectors Access Control • 6220S -System printer used with � 4100SM serial module • 5193SD • VISTAKEY" V-Plex(addressable) •5193SDT Access Control Two-Wire Smoke Detectors • VISTAKEY-SK Starter Kit Conventional V-Plex Passive Infrared Detectors . VISTAKEY-EX Expansion Kit • System Sensor •998MX • ESL • IS2500SN Alarm Communications • DSC • DT7500SN • 7845i-ENT- Internet/Intranet Communicator Horn/Strobes V-Plex(Addressable)Contacts • 7845GSM - Digital Cellular • System Sensor •4939SN-WH Communicator • Wheelock •4944SN-WH • 7845i-GSM - Internet and Digital • Gentex •4959SN Cellular Communicator Manual Pull Stations V-Plex Glassbreak Detectors • GSMCF/iGSMCF- Commercial Fire • FG1625SN Communication Kits(when available) • 5140MPS-1 • IPGSM-DP Internet and Digital Cellular • 5140MPS-2 Optional 24V Kit Communicator V-Plex(Addressable) Devices • Order number: V128FBP924KT •4208U Universal Eight-zone Expansion Commercial Wireless Devices Module • 5808W3- Photoelectric Smoke/Heat • 4101 SN Single Relay/Zone Module Detector Product specifications subject to change. ORDERING V128FBP-9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9-24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information:www.honeywell.com/security Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 Honeywe" P.O. Box 9040 Melville, NY 11747 wsrA,zaFaPOi� 1.800.467.5875 september 20�2 www.honeywell.com OO 20�2 Honeywell International Inc. ���:�:GFI��IF't�IEC;:�::�:�+:,�: = FEHC�',' T��i i��:f°1 6160 �- ALPHA DISPLAY KEYPAD �4 — ��*.r:�ISRR�IE����* i -i = ��AU4' T� ��`M i WITH DOOR ATTACHED ..,,�� .�.. f „ z m 3 ,:. ��_ .� a w s - i s,w. .�r. �,-., a 9.� � .,:;. a x WITHOUT DOOR The 6160 Deluxe Keypad is easy to install and simple to The oversized function keys are easily accessed even when use. The attractive white console blends with any decor and the keypad door is closed, and can be programmed for fire, features a contoured, removable door that conceals burglary, personal emergencies and other operations. Colored illuminated soft-touch keys. The 6160 also features a new self-adhesive labels are included. larger and brighter 32-character display with easy-to-read plain-English status messages. FEATURES • Large, easy-to-use keypad • Zones and system events displayed • System functions clearly labeled • Keys continuously backlit for greater in plain English • Functions performed by just entering visibility • No confusing blinking lights security code plus command • Speaker with audible beeps • Four programmable function keys • White with removable door blends to indicate: with any decor - System status - Entry/exit delay - Other alarm situations SPECIFICATIONS Physical Wiring Compatibility • 5-5/16"H x 7-3/8"W x 1-3/16"D • - (Black): Ground • Fully compatible with all (135mm x 190mm x 30mm) . + (Red): +12 VDC (Aux. Power) VISTA controls. Current • D1 (Green): "Data in"to control panel • Standby-40mA • DO (Yellow):"Data out"from •Activated Transmission-160mA control panel ORDERING 6160 Alpha Display Keypad Honeywell Security&Custom Electronics �������' Honeywell International Inc. PO Box 9035 cooso,o Syosset, NY 11791 U6160/D September 2006 www.honeywell.com o 2oos HoneyWeu inter�at�o�ai i��. Honeywell 5192S D/5192S DT V-PLEX° SMOKE DETECTOR r `�,. � �� �` �i�' • �; -t �� �'",r� - >,�.. ,�,r>`' The Honeywell 5192 Series low profile, addressable V-Plex control, via the V-Plex addressable loop, to indicate locally smoke detectors deliver state-of-the-art features and and at the central station that the detector may not be able benefits in a cost-effective package. These detectors are to detect smoke or may false alarm. This feature works designed to provide open area coverage and are with VISTA-32FB, 128BP, 128FBP, 250BP, 250FBP, 40, compatible with Honeywell's VISTA controls supporting 50P, 100-24 and FAP FA1600C, FA1660C and FA1700C. V-Plex technology. More important is the cost saving associated with An LED on the detector will blink periodically during normal Automatic Maintenance Reporting. The feature is an conditions, remain on steady during alarm and cease to approved alternate to NFPA 72 field sensitivity calibration pulse if the chamber is out of acceptable sensitivity range. testing that require external test meters. This eliminates the need to schedule inspections to determine detector An extremely powerful feature available within the 5192 sensitivity/viability. Another important benefit of these V-Plex Series is the Automatic Maintenance Alert/Reporting (addressable) smoke detectors is their ability to operate on capability-a feature normally found in today's high end existing wiring. analog addressable systems. The detectors continually There is no need to run special twisted pair, data grade or monitor their own sensitivity levels in addition to the basic shielded wires, providing you with the right choice for all normal and alarm conditions. These HIGH and LOW your retrofit applications. That equates to cost savings in SENSITIVITY signals are communicated back to the time and materials! FEATURES • Low profile design •Available with integral heat sensor • Lines on existing or •V-Plex addressable loop device • Simple 2 wire installation conventional wiring •Automatic maintenance reporting • DIP switch or serial number programmable APPLICATIONS The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V-Plex addressable loop technology.These agency listed alarm initiating devices support most commercial and residential applications.They are suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or professional office suites and in factory and warehouse environments. 5192S D/5192S DT V-PLEXT"' SMOKE DETECTOR SPECIFICATIONS Installation Serial number addressing is supported on Mechanical: VISTA-32FB, 128BP, 128FBP, 250BP, The 5192 Series smoke detectors are • Diameter: 5.5 inches(140mm)(including 250FBP, 100-24 and FAP FA1600C, supplied with a convenient mounting FA1660C and FA1700C controls. (Refer to mounting bracket) bracket that allows the detector to be mounted to a variety of electrical control panel and smoke detector • Height: 1.7 inches(43mm) installation instructions for details.) (including mounting bracket) junction boxes.A removable terminal block,that accepts 14 to 22 gauge wire •Weight: 5.3 ounces(150 grams) to provide easy wiring connections.The detectors are designed to meet Automatic Maintenance Reporting Compatibility all applicable requirements for UL Environmental: Commercial and Residential Fire The automatic maintenance feature is installations as well as NFPA 72 compatible with the following control • Installation temperature range: requirements when installed in panels: 32°to 100°F(0°to 38°C) compliance with the National -VISTA-32FB • Installation humidity range: Electric Code and approved/listed control -VISTA-128BP 10%to 93% RH, non-condensing panels. -VISTA-128FBP -VISTA-250BP • Heat sensor(5192SDT only): -VISTA-250FBP 135°F fixed temperature w� -FA1600C electronic thermistor °a -FA1660C • EMI: Meets or exceeds the J� -FA1700C following requirements: �z a + a + The automatic maintenance may be -FCC Part 15, Class B Device w� disabled for all other controls that -IEC EMC Directive �w `�C0 sw�rcH do not support this feature. Refer Q H REMOVABLE �d TERMINALBLOCK to control panel and smoke detector >� � Installation Instructions for details. Agency Listings Wiring diagram for 5192SD/SDT smoke detector • UL268 Commercial System Compatibillty Smoke Detector Electrical: These smoke detectors are compatible • Meets UL 217 Requirements with all VISTA control anels that su ort 'System voltage range: 7-14 V p pp Standby current(maximum @ 12�: for Residential V-Plex(addressable)polling loop technology.The detectors support -LED off: 1.2mA DIP switch or serial number addressing. -LED on: 2.8mA DIP switch configuration are compatible with 5140XM,VISTA-40, and VISTA-50P controls. ORDERING 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 v5i 9vo May 2009 www.honeywell.com o0 2009 Honeywell International Inc. �� SYSTEM � ��� SENSOR° �` -___.� � , '� BI 5600 Series Mechanical � ` Heat Detectors ��� � � + _� � . _ ...s. � � �, System Sensor's 5600 series mechanical heat detectors '� offer a low-cost means for property protection against ; � � fire, and for non-life-safety installations where smoke �` � ,,� detectors are inappropriate. `__ ?�,������� �':-` - , Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations configurations to accommodate a broad range of applications.Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- —Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to use terminal screws Installation flexibility.To satisfy a variety of installation needs, •A broad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5""and 4"Octagonal when used with a square to round plaster ring.The reversible —4""square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides dear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings � u� F M MEA «(�� a roved ��'°°'° LISTED APPROVED pp s_,oi io,aoce i.�-os-e ;zio-;zo���zz, Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate of rise element shall be activated by a rapid rise in temperature,approximately 15°F(83°C)per minute.The detector shall indude a reversible mounting bracket for mounting to 3'/z-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterlor of the housing to identify its temperature rating and activation method.The rate of rise element of combination fixed temperature/rate of rise models shall be restorable,to allow for field-testing.The detectors shall indude an external collector that shall drop upon activation to identify the unit in alarm. •. Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°Q Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(43cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz(170 grams) Rate-of-RiseThreshold 15°F(83°Q rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 3Yrinch octagonal back box 4 inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring . . Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/03A 250VDC/O.IA InputTerminals 14-22 AWG eoai� xi xi aoaixi O O O O O �4� � � o � � i � i- � 5607P 5602,5622 5603,5623 5604,5624 5621 Ordering Information - - � 5601 P Single None 135°F(57°C) Fixed Temperature/Rate of Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5603 Single Lettering 135°F(57°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 15Zm) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7b2m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. l\��� �\��� �ZOCE �_tc n Sen� �� �� 3825 Ohio Avenue•St.Charles,IL 60174 ��a��rspe<�fi��o�ss�u,��<<o�rz ge �mou�,���<e.u�s��sys�emsenso�-�omro� ��� �����R� PhOIl2:80�-SENS�RZ•FdX:63�-3��-6495 currenrproduainformation,�mdudingthelares[verslonofthlsdatasheet. A05-0351-002•11/06•i31676 Honeywell 580000 CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER ` I� � � U� U�C The 580000 is a 3V battery powered wireless carbon The detector consists of an electrochemical carbon monoxide (CO) detector intended for use with Honeywell monoxide sensor assembly coupled with a wireless alarm systems that support 5800 Series wireless devices. transmitter. The transmitter can send alarm, trouble, It provides early warning when its electrochemical sensing end-of-life, tamper and low battery condition messages technology measures carbon monoxide levels in the air. to the alarm panel. The 580000 is specifically designed for system operation Since there are no holes to drill or wires to run, you can and is fully listed to UL 2075 as a system supervised preserve the beauty of the home or building while detector.� It contains a piezoelectric horn which generates protecting its occupants from harmful carbon monoxide the ANSI S3.41 temporal 4 pattern in an alarm condition. gas. The 580000 is an ideal carbon monoxide detector for difficult to wire locations, applications where room aesthetics are critical or where hazardous materials exist. What is Carbon Monoxide and How Can it Harm Consumers? Carbon monoxide (CO) is an odorless, colorless, tasteless and highly toxic gas that is produced when fuels such as wood, gasoline, charcoal and oil are burned with insufficient air. The majority of residential and commercial fatalities caused from these fuels come from heating systems, engine powered tools and charcoal grills. Carbon monoxide is harmful when inhaled because it displaces oxygen in the blood and deprives the heart, brain and other vital organs of oxygen. Large amounts of CO can overcome a person in minutes without warning—causing them to lose consciousness and suffocate. The 580000 is designed to warn the end-user well before the CO reaches a fatal level. The detector's CO sensitivity is evaluated to UL 2034. CO Levels and Time to Alarm CO Concentration Min.Time to Alarm Max.Time to Alarm 30 ppm +/- 5 ppm 30 days Indefinite`* 70 ppm +/- 5 ppm 60 minutes 240 minutes 150 ppm+/- 5 ppm 10 minutes 50 minutes 400 ppm+/- 5 ppm 4 minutes 15 minutes `For a complete list of products that support system operation of the 580000 to UL standard 2075, please visit: www.honeywell.com/security/hsc/resources/agency/co ""Life of product 580oC0 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER KEY FEATURES Electrochemical Sensing Technology- Electrochemical Full Supervision -The 580000 is fully supervised to monitor detectors are the newest, most refined CO detectors available for low battery, case tamper and trouble conditions. and provide the most accurate measurement of CO Test/Hush Button -This dual purpose button allows the concentration obtainable. They can take readings from low end-user to perform periodic testing of the detector. In the levels that may be hazardous over long periods of time to event of a CO alarm, this button will silence the local sounder high concentrations that present an immediate danger. alarm for a five minute period. Note: the Hush feature will not Local Sounder-A built-in piezoelectric horn generates the operate at levels above 350 ppm (parts per million)carbon ANSI S3.41 temporal 4 pattern in an alarm condition. The monoxide (see figure 1). local sounder will also alert the end-user of other conditions Versatile Mounting -Whether you choose to affix the such as low battery, detector trouble and end-of-life. detector to the ceiling or a wall, mounting is made simple LED Status Indicators - Dual LEDs provide local visual with the enclosed hardware. The mounting base has large indication of the detector's status—including normal operation, mounting ports, which accommodate drywall anchors for alarm, low battery, trouble and end-of-life (see figure 1). easy surface mounting (see figure 2). End of Life Timer-When the detector has reached the end Tamper Protection and Tamper Resistant Element - of its life, the detector will send a trouble signal to the panel. The detector has a built-in tamper switch that can This indicates that the CO sensor inside the detector has communicate back to the control panel in the event it is passed the end of its life and the detector needs to be removed from the base. For an added level of security, replaced.The detector's lifespan is approximately six years the detector also includes a tamper resistant element that from the date of manufacture. prevents removal from the base without the use of a tool (see figure 2). � � MOUNTING ' SCREWS � (INSTALLED) i . i � I / ��hJO � \ I /�v�\` � ��'��N,� J \ / � ���f \ ; ��J ' ' �I i � \ TEST BUTTON � � �� � i � ��'°nedd� � � � aa'�ow >eti�ue � ow � � �,°+� snH �o�o � d��N�Hedm I TAMPER e ao� N 1s�1 °6� � s °n+ i RELEASE TAB GREEN LED a� o� i �1l1dlF,� ��� ' CUT OFF �� 5 Q � ��'U���� t� SMALL TAB TO �O o °� i �� � ��� ACTIVATE � �` i ti �� TAMPER RESIST �q ooN°SeP � � �y \ �Z X � FEATURE) RM i Z = O O / , RED LED I � �/ i �'� Z � / � Q � � i �P � i � ENGAGE NOTCH WITH � TAMPER RELEASE TAB � ON BASE AND TURN i CLOCKWISE TO LOCK i Figure 1 ; Figure 2 580oC0 Honeywell CARBON MONOXIDE DETECTOR WITH BUILT-IN WIRELESS TRANSMITTER MOUNTING RECOMMENDATIONS CO is slightly lighter than air and when heated by a fuel-burning source, the lighter weight and warm temperature of the CO causes it to quickly rise to the ceiling and mix freely with the air. Check with the local Authority Having Jurisdiction (AHJ)for CO detector requirements in your area. Some recommendations for installing the 580000 are as follows: - On every floor of the facility - Inside any areas that contain a fuel-burning appliance - In the vicinity of flame-fueled appliances, but no closer than 10 feet ■ • For wall mount BEDROOM - The detector should be at least as high as a light � switch and at least six inches from the ceiling To BEDROOM gR BEDROOM • For ceiling mount � KITCHEN GARAGE - The detector should be at least 12 inches from , CLOSED LIVING DOOR any wall ROOM ■ BASEMENT � CARBON MONOXIDE ALARM LOCATION FOR MULTI-LEVEL RESIDENCE SPECIFICATIONS • Power Source: One 3V CR123A lithium battery (included) • Audible Signal (temporal 4 tone): 85 dB in alarm (at 10 ft.) • Height: 2.3" (58mm) • Diameter: 5.3" (135mm) with mounting base • Weight: 7 oz. (241 g) without battery • Operating Ambient Temperature Range: 32° F to 100° F(0° C to 37.8° C) • Operating Humidity Range: 15%to 95% relative humidity, non-condensing • Agency Listings: - Listed to UL standard 2075, 'CO sensitivity is evaluated to UL 2034 - 580000A ULC Listed - tested to the CAN/CSA 6.19.01 standard ORDERING 580000 Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter 580000A Wireless Carbon Monoxide Detector with Built-in Wireless Transmitter with ULC listing `For a complete list of products that support system operation of the 580000 to UL standard 2075 and 580000A ULC standard, please visit: www.honeywell.com/security/hsc/resources/agency/co Automation and Control Solutions Honeywell Security&Communications Honeywell 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 U580000D/D March 2009 www.honeywell.com oO 2009 Honeyweu�nternationa��nc. �� SYSTEM _ - �. �d� � SENSOR° ,� �n � � =: —_ Mini-Horns ; � _=:�� � - ---�_ � -�-.�.., - - � -_—_�-` � -� - -� -,�--�, i � The SpectrAlert°Advance series of mini-horn sounders are �_�-.� ��--�— `�._� �—��— designed to simplify installations to provide primary and -��``=°�- � — -- �-� � � �- ---� — secondary signaling for fire and security applications. �'+� C?�� SPECTR�ert A � V A N C E Features The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications,where a • 12 and 24V operation smaller notification device is desired.The mini-horns offer high and • High and low volume settings low volume settings,and temporal or non-temporal tones. The horns • Temporal and non-temporal tones can be mounted to single gang back boxes for aesthetically sensitive Mounts to singie gang back box applications. Synchronization is also provided when using the � MDL module. • Compatible with MDL sync module • Mechanically and electrically compatible with PA400 series The MHR and MHW mini-horns can operate between 32 and 120 Mini-AlertT'"sounders degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply.They are listed to Underwriter's Laboratories • Listing for ceiling or wall mounting Standard UL 464 for fire protective signaling systems. Agency Listings U ���� o L F M I I I�+ l=��J=/ IJ Llr �k w LISTED APPROVED 54011 3028007 CS1099 7135-1653:196 SpectrAlert°Advance Mini-Horn Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a deep single gang back box.Mini-horn shall be listed to Underwriter's Laboratories Standard UL464 for fire protective signaling systems.Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified, unfiltered power supply.When used with the Sync•Circuit'M Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.6"L x 2.9"W x .45"D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F(0°C to 49°C) Mounting Surface:deep single-gang back box(23/a'"deep) Flush:Standard 4""x 4""back box with single gang mud ring,which allows sufficient clearance for conduit entrance. .- InputTerminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8-33 Operating Voltage with MDL 9-33 UL Sound Output and Current Draw Data . Switch Setting Pattern Output Level 8-17.5 VDC 8-17.5 VFWR Nominal 12 Nominal 12 16-33 16-33 VDC VFWR VDC VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- High 72 71 75 74 80 79 temporal 4 Non- Low 70 69 73 72 78 77 temporal _ � 8-17.5 Volts 16-33 Volts Switch Position Sound Pattern Volume DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Ordering Information .- MHR Mini-Horn,Red MHW Mini-Horn,White l\��� �STEM 002012 System Sensor. �� 1 ✓ 3825 Ohio Avenue•St.Charles, IL 60174 P�oducts�ecit�icationssubjeatochanyewahoutnotice,Visitsystemse�soccom ��y� SE/VSORr Phone:800-SENSOR2•Fax:630-377-6495 forcurrentproductinto�mation,mdudmgme�atestve�sionofmisdatasheet. AVDS01500•3112 �� SYSTEM ��� SENSOR� � �'� � �. � � ���� . �� � _ .��' . �� Selectable-Output � �'�..� Horns, Strobes, and � � Horn Strobes -_,i� � SpectrAlert°Advanceselectable-outputhorns,strobes, ' ` "���' and horn strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTf��C� A � V A N E Features The SpectrAlert Advance series offers the most versatile and •Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. •Tamper-resistant construction With white and red plastic housings,wall and ceiling mounting options,and plain and FIRE-printed devices,SpectrAlert Advance can •Automatic selection of 12-or 24-volt operation at 15 and 15/75 meet virtually any application requirement. candela •Field-selectable candela settings on wall and ceiling units:15, 15/75, Like the entire SpectrAlert Advance product line,horns,strobes, 30,75,95,1 10,1 15,135,150,177,and 185 and horn strobes include a variety of features that increase their •Horn rated at 88+dBA at 16 volts application versatility while simplifying installation.All devices •Rotary switch for hom tone and three volume selections feature plug-in designs with minimal intrusion into the back box,which make installations fast and foolproof while virtually •Universal mounting plate for wall and ceiling units eliminating costly and time-consuming ground faults.Furthermore, •Mounting plate shorting spring checks wiring continuity before a universal mounting plate with an onboard shorting spring tests device installation wiring continuity before the device is installed,protecting devices •Electrically compatible with existing SpectrAlert products from damage. •Compatible with MDL sync module In addition,field-selectable candela settings,automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. Agency Listings '-=��;;�..�,� SIGNALING I(��,��1 O �� � o� F M MEA `'� a roved �,zs-�bsa�8e���,�oo�s«o�es� LISTED aarAOVeo PP �izs-ies3:�aamo�nsc����s, 540'l(chimes,ho:nstrobes,horn) 3023577 MEA452-OS-E chlrnesvobes) SSSl7(sttobes) 7135-1653:189(homs,chirnes) SpectrAlert Advance Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 1�/z-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 1'/s-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,SpectrAlert Advance products,when used with the SynoCircuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SynaCircult Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts,24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings induding 15,15/75,30, 75,95,1 10,115,135,150,177,and 185. Strobe The strobe shall be a System Sensar SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective serviceThe strobe shall be wired as a primary signaling noiification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4"/,e x 4"/,6 x 2'/a-inch back box.The module shall also control two Style Y(dass B)circuits or one Style Z (dass A)circuitThe module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F(0°C to 49°q Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 175V(12V nominaq or 16 to 33 V(24V nominaD InputTerminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(induding lens) 6.8""diameter x 2.S"high(173 mm diameter x 64 mm high) Wall-Mount Dimensions(induding lens) 5.6""L x 4.7""W x 2.5`D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"'L x 4.7""W x 13`D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Back Box Skirt Dimensions(BBS-2,BBSW-2) 5.9""L x 5.0"W x Z2`D(151 mm L x 128 mm W x 56 mm D) Ceiling-Mount Back Box Skirt Dimensions(BBSG2,BBSCW-2) 7.1""diameter x 2.2`high(180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS,TRW-HS) 5.7"'L x 4.8""W x 035"D(145 mm L x 122 mm W x 9 mm D) Ceiling-MountTrim Ring Dimensions(sold as a 5 pack)(TRGHS,TRCW-HS) 6.9""diameter x 03S"high(175 mm diameter x 9 mm high) Notes: L Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-007 UL Current Draw Data � � 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern d6 DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 U6 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 - � - 8-17.5 Volts 16-33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non Temporal Low 132 154 80 90 105 161 184 202 211 . 16-33 Volts 16-33 Volts DClnput 135 150 177 185 FWRlnput 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data . 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern d6 DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 �Settings 7,8,and 9 are not available on 2 wire horn strobe. A05-0395-007 SpectrAlert Advance Dimensions �4.7" 25" _ 6.8" Dia. ��,e... � 5 ,� , � __ � ��a _.,� /; � � � a� � �� � 0 ' � / _s---�___1- ' , I 2.5' 5.6` 7.`' �� �'�,.`.....,�� — a ' � Wall-mount horn strobes Ceiling-mount horn strobes 7.1" I'-2.25� 5.05'� �«223�I Dia. � I I OOo� a OOo�C� 5.95" 0 0 0 � o � � � ° � � Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information •- �- Wall Horn Strobes Ceiling Strobes P2R*' 2-Wire Horn Strobe,Standard cd$,Red SCR Strobe,Standard cd,Red P2RH* 2-Wire Horn Strobe,High cd,Red SCRH Strobe,High cd,Red P2Wx 2-Wire Horn Strobe,Standard cd,White SCW* Strobe,Standard cd,White P2WH* 2-Wire Horn Strobe,High cd,White SCWH Strobe,High cd,White P4R* 4-Wire Horn Strobe,Standard cd,Red Horns P4RH 4-Wire Horn Strobe,High cd,Red HR Horn,Red P4W 4Wire Horn Strobe,Standard cd,White HW Horn,White Wall Strobes Accessories SR*' Strobe,Standard cd,Red BBS-2 Back Box Skirt,Wall,Red SRH*' Strobe,High cd,Red BBSW-2 Back Box Skirt,Wall,White SW�` Strobe,Standard cd,White BBSC-2 Back Box Skirt,Ceiling,Red SWH' Strobe,High cd,White BBSCW-2 Back Box Skirt,Ceiling,White Ceiling Horn Strobes TR-HS Trim Ring,Wall,Red PQR� 2-Wire Horn Strobe,Standard cd,Red TRW-HS Trim Ring,Wall White PQRH 2-Wire Horn Strobe,High cd,Red TRC-HS Trim Ring,Ceiling,Red PCZW*' 2-Wire Horn Strobe,Standard cd,White TRCW HS Trim Ring,Ceiling,White PC2WH* 2-Wire Horn Strobe,High cd,White PC4R 4-Wire Horn Strobe,Standard cd,Red PC4RH 4Wire Horn Strobe,High cd,Red PC4W 4-Wire Horn Strobe,Standard cd,White Notes: *Add"-P"to model numberfor plain housing(no°FIRE°marking on cover),e.g.,P2R-P. t Add"-SP"to model number for°FUEGO"marking on cover,e.g.,P2R-SP. #"Standard cd"refers to strobes that indude 15,15/75,30,75,95,110,and 115 candela settings."High cd°refers to strobes that indude 135,150,177,and 185 candela settings. �� SYSTEM ozoo�s,,em sen=o�. 3825�h10 f�V2YlUe•St.�{ldY�eS,��6�174 ?roductspe6�ca�onssub�rcttorn gcwithoutnotrce.uis�sysremsensor.comfor ��� �����R Ph0112:8��-SENS�RZ•FdX:63�-3��-6495 curcen[produc[Inforrna[ion,�mduding[helarestversionotthlsdatasheet A05-0395-007•4/09•II2132