HomeMy WebLinkAboutB13-0554 REV2 fire rated outlet Bulletin 20-066/March 2009 The Un�co System° �uc�,�u��rnr�s�EC►�rc�r�onrs UPC-56FR Firestop, Duct Outlet, 1 -hour, UL-555C* Part No. Application UPG56FR — X Designed for floor, ceiling, or wall applications where the supply outlets are located in a 1-hour X = Quantity in box or less F rated structure. The firestop is designed for static conditions, meaning that the fire suppression system should turn off the air Package Contents flow in the event of a fire. -Firestop, White -2 Toggles and Screws per outlet It is dimensionally identical to the standard -Instruction sheet Unico round outlet (UPG56B) and should be installed in the same manner as all other Unico round outlets. *Patent Pending � � ;�� . _ ��„„„ � ;�'. . I P F� ��111 . _ •15 � - �� ��� UPC-56FR �N�ERrEk Listed Duct Outlet v� 1-hour F-Rating :�M per UL 555C �drhockHe�Sea US O Copyright 2006 Unico,Inc Bulletin 20-066— Page 2 UPC-56FR Firestop Duct Outlet* Installation Instructions ���_ ----� ����. 1f � 55 I I �I �. �---� � ' ^ ' ����������M1�—= �� � �4.� � � � _ _ ,. --- , '"� ��I � � - - � `.� ��',� �"� � �� � , i ; �°= ��`� ? 5 �_,__---� � I ,_- `� � � • '�ap �}. _ - k -_-- �� � - . �+I� ~ �� -~ —�— i .. '.�I ��� �r 5 � 'r� � ! � � f� �� �i � � � L �� '� ___ �� � ���. �- �. ___ L Floor or Ceiling Assembly—Minimum 1-inch thick or 2layers 1/2-inch thick fire-rated gypsum board constructed per IMC 2000. Diameter of opening to be 4-inches (102 mm). 2. Firestop Outlet—One firestop outlet centered within opening. The firestop outlet consists of a 3.3 inch diameter x 1 inch galvanized steel tube with an intumescent material lining. The firestop outlet must be installed in accordance with this instruction. The firestop outlet is secured in place with the supplied toggles and screw. UNICO,INC.—UPG56FR 2A.Caulk—(Optional, not shown)—As an option,the firestop outlet can be further sealed with a bead of fire-rated caulk between the back of the firestop outlet and the ceiling assembly. SPECIFIED TECHNOLOGIES INC—SpecSeal 100, 101, 102, 105 3. Screw-#4 x 1.5 inch long screw. Two per device. 4. Toggle—Single-sided toggle. Two per device. 5. Duct—Unico Sound Attenuator or Supply Tubing rated as an Air Duct per UL Standard 181. Peel back the insulation and secure the inner duct to the Firestop device using a metal hose clamp. Straighten the insulation and outer vapor barrier of the duct and stuff into and under the metal tube lined with the intumescent material. UNICO,INC.—UPG25, UPG26C 6. Tape—Secure and seal the duct vapar barrier to the outside of firestop metal tube with aluminum tape listed per UL Standard 181 A-P. Tape must bear the UL mark. 7. Clamp—Metal clamp to secure the duct to the Firestop Outlet. UPC-56FR �N�ERrFk Listed Duct Outlet v� 1-hour F-Rating :�M per UL 555C �drnockHe�yea US OO Copyright 2006 Unico,Inc "Patent Pending