HomeMy WebLinkAboutB14-0048 plans APPROVEDGENERAL NOTES: 1. D O N O T S C A L E D R A W I N G S . V E R I F Y D I M E N S I O N S I N F I E L D P R I O R T O C O M M E N C E M E N T O F W O R K . 2. A L L S U B C O N T R A C T O R S S H A L L B E L I C E N S E D , E X P E R I E N C E D , A N D T H O R O U G H L Y KN O W L E D G E A B L E I N T H E I R R E S P E C T I V E A R E A S O F T H E C O N S T R U C T I O N I N D U S T R Y A N D S H A L L PE R F O R M I N A R E S P O N S I B L E M A N N E R W I T H ES T A B L I S H E D C O N S T R U C T I O N S E Q U E N C E , S H A L L RE C O G N I Z E T H E P R I O R I T Y O F T H E C O N S T R U C T I O N D O C U M E N T S , A N D S H A L L I N F O R M T H E P R I M E CO N T R A C T O R O F P O T E N T I A L P R O B L E M S W H E N T H E C O N S T R U C T I O N D O C U M E N T S A R E U N C L E A R OR I N C O N S I S T E N T . 3. S U B C O N T R A C T O R S S H A L L B E R E S P O N S I B L E T O N O T I F Y T H E P R I M E C O N T R A C T O R O F DI S C R E P A N C I E S O R C O N F L I C T S I N T H E C O N S T R U C T I O N D O C U M E N T S F O U N D D U R I N G B I D D I N G AN D / O R P R I O R T O P E RF O R M I N G T H E W O R K . 4. E X A M I N A T I O N O F B I D D I N G D O C U M E N T S . A. E A C H B I D D E R S H A L L E X A M I N E T H E B I D D I N G D O C U M E N T S C A R E F U L L Y , A N D N O T L A T E R T H A N SE V E N ( 7 ) D A Y S P R I O R T O T H E D A T E O F R E C E I P T O F B I D S , S H A L L M A K E W R I T T E N R E Q U E S T TO T H E C O N S T R U C T I O N M A N A G E R F O R I N TE R P R E T A T I O N O R C O R R E C T I O N O F A N Y DI S C R E P A N C I E S , A M B I G U I T I E S , I N C O N S I S T E N C I E S , O R E R R O RS THEREIN WHICH HE MAY DI S C O V E R . T H E C O N S T R U C T I O N M A N A G E R W I L L I S S U E A N Y I N T E R P R E T A T I O N O R CO R R E C T I O N A S A N A D D E N D U M . O N L Y A W R I T T E N I N T E R P R E T A T I O N O R C O R R E C T I O N B Y AD D E N D U M S H A L L B E B I N D I N G . N O B I D D ER S H A L L R E L Y U P O N I N T E R P R E T A T I O N S O R CO R R E C T I O N S G I V E N B Y A N Y O T H E R M E T H O D . I F D I S C R E P A N C I E S , A M B I G U I T I E S , IN C O N S I S T E N C I E S , O R ER R O R S A R E N O T C O V E R E D B Y A D D E N D U M O R W R I T T E N D I R E C T I V E , CO N T R A C T O R S H A L L I N C L U D E I N H I S B I D, L A B O R M A T E R I A L S A N D M E T H O D S O F CO N S T R U C T I O N R E S U L T I N G I N H I G H E R C O S T . A F T E R A W A R D O F C O N T R A C T , N O AL L O W A N C E O R E X T R A C O M P E N S A T I O N W I L L BE M A D E O N B E H A L F O F T H E C O N T R A C T O R DU E T O H I S F A I L U R E T O M A K E T H E W R I T T E N R E Q U E S T S A S D E S C R I B E D A B O V E . B. F A I L U R E T O R E Q U E S T C L A R I F I C A T I O N D U R I NG T H E B I D P E R I O D O F A N Y I N A D E Q U A C Y , OM I S S I O N , O R C O N F L I C T W I L L N O T R E L I E V E T H E C O N T R A C T O R O F H I S R E S P O N S I B I L I T I E S . TH E S I G N I N G O F T H E C O N T R A C T W I L L B E C O N S I D E R E D A S I M P L I C I T L Y D E N O T I N G T H A T T H E CO N T R A C T O R H A S A T H O R O U G H C O M P R E H E N S IO N O F T H E F U L L I N T E N T A N D S C O P E O F TH E C O N S T R U C T I O N C O N T R A C T D R A W I N G S A N D S P E C I F I C A T I O N S . 6. P R O V I D E A B A S E B I D W H I C H S H A L L I N C L U D E ON L Y S P E C I F I E D E Q U I P M E N T O R E Q U I P M E N T LI S T E D A S E Q U I V A L E N T . N O S U B S T I T U T I O N S F O R T H E L I S T E D E Q U I P M E N T S H A L L B E A L L O W E D I N TH E B A S E B I D . A. T H E M A N U F A C T U R E R O F E Q U I P M E N T O R M A T E R I A L S F I R S T N A M E D O N T H E D R A W I N G S I S TH E B A S I S O F D E S I G N . O T H E R M A N U F A C T U R E R S L I S T E D A R E C O N S I D E R E D G E N E R A L EQ U I V A L E N T S O N L Y . B. C O O R D I N A T I O N O F G E N E R A L E Q U I V A L E N T S A N D S U B S T I T U T I O N S : W H E R E C O N T R A C T DO C U M E N T S P E R M I T S E L E C T I O N F R O M S E VE R A L G E N E R A L E Q U I V A L E N T S , O R W H E R E SU B S T I T U T I O N S A R E A U T H O R I Z E D , C O O R D I N A T E C L E A R A N C E A N D O T H E R I N T E R F A C E RE Q U I R E M E N T S W I T H M E C H A N I C A L A N D O T H E R W O R K . 1) P R O V I D E N E C E S S A R Y A D D I T I O N A L I T E M S S O T H A T S E L E C T E D O R S U B S T I T U T E D I T E M OP E R A T E S E Q U I V A L E N T T O T H E B A S I S O F D E S I G N A N D P R O P E R L Y F I T S I N T H E AV A I L A B L E S P A C E A L L O C A T E D F O R T H E B A S I S O F D E S I G N . 2) P R O V I D E A L L F E A T U R E S W H I C H A R E S T A N D A R D O N T H E B A S I S O F D E S I G N P L U S A N Y SP E C I F I E D O P T I O N S . 3) B E R E S P O N S I B L E F O R A S S U R I N G T H A T P I P I N G , C O N D U I T , D U C T , F L U E , A N D O T H E R SE R V I C E L O C A T I O N S F O R G E NE R A L E Q U I V A L E N T S O R S U B S T I T U T I O N S D O N O T C A U S E AC C E S S , S E R V I C E , O R O P E R A T I O N A L D I F F I C U L T I E S A N Y G R E A T E R T H A T W O U L D B E EN C O U N T E R E D W I T H T H E B A S E D E S I G N . 7. I N A S M U C H A S D E S I G N F O R R E M O D E L A N D / O R R E H A B I L I T A T I O N R E Q U I R E S T H A T C E R T A I N AS S U M P T I O N S B E M A D E R E G A R D I N G E X I S T I N G C O N D I T I O N S , A N D B E C A U S E S O M E O F T H E S E AS S U M P T I O N S C A N N O T B E V E R I F I E D W I T H O U T D E S T R O Y I N G O T H E R W I S E A D E Q U A T E O R SE R V I C E A B L E P O R T I O N S O F T H E B U I L D I N G , T H E E N G I N E E R C A N N O T A S S U R E T H E O W N E R O R TH E C O N T R A C T O R T H A T T H E P R O F E S S I O N A L C O N S U L T I N G S E R V I C E S H E R E I N E N C O M P A S S A L L CO N T I N G E N C I E S . F I E L D C O O R D I N A T I O N D U R I NG C O N S T R U C T I O N I S I M P E R A T I V E . M A K E RE A S O N A B L E A L L O W A N C E S F O R U N S E E N C O N D I T I O N S . 8. T H E E X I S T I N G B U I L D I N G W I L L N O T B E O C C U P I E D B Y T H E O W N E R D U R I N G C O N S T R U C T I O N . 9. B E R E S P O N S I B L E T O F I E L D V E R I F Y E X I S T I N G E Q U I P M E N T O R D U C T W O R K R E M A I N I N G T O B E CO N N E C T E D T O N E W O R E X I S T I N G S Y S T E M S . P R O V I D E D U C T W O R K , P I P I N G , C O N T R O L S , DI F F U S E R S , E T C . , A S R E Q U I R E D T O R E S T O R E C O N T I N U I T Y O F S Y S T E M ( S ) , O R T O M A K E N E W WO R K M E E T E X I S T I N G C O N D I T I O N S , W H E T H E R I N D I C A T E D O R N O T . 10.SUBCONTRACTOR SHALL VERIFY EXISTENCE AND LOCATION OF ALL UTILITY SERVICES AND COORDINATE AS REQUIRED BY THEIR RESPECTIVE AREA OF THE CONSTRUCTION, NOTIFYING THE PRIME CONTRACTOR OF VARIATIONS OR CONFLICTS.11.IF NOT SPECIFICALLY DEFINED IN THESE CONSTRUCTION DOCUMENTS, MATERIALS AND/OR EQUIPMENT SHALL BE IDENTIFIED BY THE SUBCONTRACTOR WITH SUFFICIENT TIME TO ALLOW SELECTION, PURCHASE, AND DELIVERY TO MAINTAIN CONSTRUCTION SCHEDULE.12.PROVIDE MECHANICAL DEMOLITION AS REQUIRED. VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. EXISTING FIXTURES, MECHANICAL EQUIPMENT, ETC., BEING REMOVED SHALL BE OFFERED TO THE OWNER WHOM SHALL HAVE FIRST RIGHT OF REFUSAL.DISPOSE OF ALL REMOVED PIPING, DUCTWORK, ETC. UNLESS NOTED OTHERWISE. PIPES,DUCTWORK, EQUIPMENT, ETC. TO BE REMOVED, ARE SHOWN HATCHED, UNLESS OTHERWISE NOTED.13.OFFSET PIPING, DUCTWORK, ETC. AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS, AND COLUMNS, AND EXISTING EQUIPMENT.14.ALL EXISTING SUPPORT RODS AND STRAPS NOW SUPPORTING DUCTS, PIPES, AIR TUBING,ELECTRICAL CONDUIT, ETC. THAT ARE REMOVED TO ALLOW ROOM FOR INSTALLATION OF NEW EQUIPMENT SHALL BE RELOCATED AND REINSTALLED, OR REPLACED IF DAMAGED.15.WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT, OWNER, AND ENGINEER.16.IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM HIS/HER WORK IN CONFORMANCE WITH ALL APPLICABLE CODES, ORDINANCES AND LIFE SAFETY FEATURES AS REQUIRED BY LOCAL,STATE, OR NATIONAL AUTHORITIES. THE CONTRACTOR SHALL VERIFY WITH THE CONSTRUCTION MANAGER IF MODIFICATION OF HIS/HER WORK IS REQUIRED FOR COMPLIANCE.17.ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE, OR EXCEED THE MINIMUM MATERIAL AND METHOD REQUIREMENTS OF THE 2012 INTERNATIONAL BUILDING, MECHANICAL,PLUMBING, FIRE AND 2011 NATIONAL ELECTRICAL CODES, MOST CURRENT NFPA, ALL LOCAL ORDINANCES AND AMENDMENTS AND MANUFACTURER'S INSTALLATION RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS EXISTS, THE MOST STRINGENT REQUIREMENT SHALL APPLY.18.PAY FOR AND SECURE ALL REQUIRED PERMITS AND INSPECTIONS. PRIOR TO FINAL PAYMENT,TURN OVER TO ARCHITECT ALL CERTIFICATES OF COMPLETION.19.WARRANTY THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP. THE WARRANTY SHALL BE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER.20.SUBMIT RECORD DOCUMENTS TO ENGINEER. DOCUMENTS SHALL INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS, ALTERATIONS, REROUTINGS, ETC.21.SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER.22.SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF TESTS OF WORK ARE DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO ADDITIONAL COST TO OWNER.23.ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED AS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS.24.FAILURE TO ORDER, OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.25.REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY, APPEARANCE OR FUNCTION.26.PROVIDE 4” HIGH CONCRETE EQUIPMENT PADS BENEATH FLOOR MOUNTED MECHANICAL EQUIPMENT, IN ADDITION TO ANY BASE ASSEMBLIES REQUIRED OR RECOMMENDED BY THE MANUFACTURER.27.CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE AVAILABLE. '* ' I S S U E D F O R I N F O R M A T I O N O N L Y ' ' N O T P A R T O F S E T ' ' I S S U E D A S P A R T O F A S E T IS S U E L O G K E Y : # DATE IS S U E L O G S H E E T I N D E X TI T L E ME C H A N I C A L C O V E R S H E E T M0 . 1 50% CONSTRUCTION DOC. 11/01/2013 EN L A R G E D M E C H A N I C A L R O O M D E M O L I T I O N P L A N MD 1 . 0 ME C H A N I C A L W A T E R F L O W D E M O L I T I O N D I A G R A M MD 2 . 0 EN L A R G E D M E C H A N I C A L R O O M P L A N M1 . 0 ME C H A N I C A L W A T E R F L O W D I A G R A M M2 . 0 ME C H A N I C A L D O M E S T I C W A T E R F L O W D I A G R A M S M2 . 1 ME C H A N I C A L D I A G R A M S M3 . 0 ME C H A N I C A L C O N T R O L S M4 . 0 M5 . 0 ME C H A N I C A L S C H E D U L E S M1 . 6 M1 . 7 MO U N T A I N H A U S B O I L E R R E P L A C E M E N T BE A U D I N G A N Z E C O N S U L T I N G E N G I N E E R S 22 2 C H A P E L P L A C E U N I T A C - 2 0 1 AV O N , C O 8 1 6 2 0 PH : 9 7 0 . 9 4 9 . 6 1 0 8 BG C E P R O J E C T N U M B E R : 3 5 4 4 . 2 0 UNIT PRICING 1.PROVIDE UNIT PRICING TO REMOVE AND REPLACE EXISTING NON RATED FIRE DOOR WITH NEW RATED DOOR AND FRAME ASSEMBLY.2.PROVIDE UNIT PRICING FOR FIRE CAULKING EXISTING PIPING PENETRATIONS THROUGH BOILER ROOM WALL.3.PROVIDE UNIT PRICING FOR FLOOR PROTECTION FOR CORRIDOR FROM VAIL'S COVERED BRIDGE TO BOILER ROOM.4.PROVIDE UNIT PRICING FOR DEMOLITION AND REPAIR OF 5/8" GYPSUM BOARD CEILING.5.PROVIDE UNIT PRICING FOR INSTALLATION OF 1-1/2" DHW WITH INSULATION. EA G L E VA I L SC A L E : ST A T E L O C A T I O N P L A N NO N E SC A L E : AR E A M A P NO N E CO V E R S H E E T G0 . 0 PRICING BREAKOUTS 1.Provide pricing breakout for boiler flue pressure test and replacement of boiler flue should it fail the pressure test. EL E C T R I C A L C O V E R S H E E T E 0 . 1 BO I L E R R O O M E L E C T R I C A L D E M O L I T I O N P L A N ED 1 . 0 BO I L E R R O O M E L E C T R I C A L P L A N E1 . 0 EL E C T R I C A L O N E L I N E D I A G R A M A N D S C H E D U L E S E2 . 0 VA I L ' S M O U N T A I N H A U S A T T H E C O V E R E D B R I D G E 29 2 E A S T M E A D O W D R . VA I L , C O 8 1 6 5 7 SC A L E : KE Y P L A N NO N E M6 . 0 EN L A R G E M E C H A N I C A L R O O M S E C T I O N V I E W 100% CD / PE R MIT 03/18/2014 M1 . 1 SI X T H F L O O R M E C H A N I C A L P I P I N G P L A N PE N T H O U S E M E C H A N I C AL P I P I N G P L A N S PA R T I A L L O W E R L E V E L M E C H A N I C A L P L A N G0.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420G00.dwg Printed By: eng-ntt March 18, 2014 - 5:29pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW COVER SHEET '*' ISSUED FOR INFORMATION ONLY' ' NOT PART OF SET' ' ISSUED AS PART OF A SETISSUE LOG KEY:#DATEISSUE LOG MECHANICAL SHEET INDEX TITLE MECHANICAL COVER SHEETM0.150% CONSTRUCTION DOC.11/01/2013ENLARGED MECHANICAL ROOM DEMOLITION PLANMD1.0 MECHANICAL WATER FLOW DEMOLITION DIAGRAMMD2.0 ENLARGED MECHANICAL ROOM PLANM1.0 MECHANICAL WATER FLOW DIAGRAMM2.0 MECHANICAL DOMESTIC WATER FLOW DIAGRAMSM2.1 MECHANICAL DIAGRAMSM3.0 MECHANICAL CONTROLSM4.0 CL G C E I L I N G ( O R C O O L I N G ) EN T E R I N G A I R T E M P E R A T U R E EA T EA E X H A U S T A I R CO N N CO DH R CO N N E C T CL E A N O U T DO M E S T I C H O T W A T E R R E C I R C BE L O W F I N I S H E D G R A D E CU B I C F E E T P E R M I N U T E ( A I R F L O W R A T E ) BO T T O M O F P I P E F R O M F I N I S H E D F L O O R CF M BO P BF G AB O V E F I N I S H E D G R A D E AF G AF F A B O V E F I N I S H E D F L O O R EN T E R I N G W A T E R T E M P E R A T U R E EW T OS A O U T S I D E A I R UN L E S S N O T E D O T H E R W I S E TY P UN O TY P I C A L OP P O S E D B L A D E V O L U M E D A M P E R OCOB D NI C ON C E N T E R NO T I N C O N T R A C T LE A V I N G A I R T E M P E R A T U R E LE A V I N G W A T E R T E M P E R A T U R E LA T LW T FB O F U R N I S H E D B Y O W N E R EX H E X H A U S T PL A N A B B R E V I A T I O N S (N ) N E W CO T G C L E A N O U T T O G R A D E GP M G A L L O N S P E R M I N U T E ( W A T E R F L O W R A T E ) RA R E T U R N A I R SA S U P P L Y A I R WI T H W/ WA L L C L E A N O U T WC O FC O F L O O R C L E A N O U T BA C K D R A F T D A M P E R BD D AU T O M A T I C AU T O AB O V E AB V CO N C C O N C R E T E CO N D C O N D E N S A T E (E ) E X I S T I N G FI R E D A M P E R FD CO M B I N A T I O N F I R E / S M O K E D A M P E R FS D KW K I L O W A T T S MO T O R O P E R A T E D D A M P E R MO D TR A N S F E R XF R T. A . T H R O W - A W A Y DW ( O R C W ) D O M E S T I C W A T E R DH W D O M E S T I C H O T W A T E R DN D O W N MA N U F A C T U R E R MF G BU I L D I N G BL D G DW R D O M E S T I C H O T W A T E R R E C I R C OA O U T S I D E A I R DI A M E T E R ØSP S T A T I C P R E S S U R E HP H O R S E P O W E R CO M B U S T I O N A I R CA HW H O T W A T E R SS S T A I N L E S S S T E E L FC T F O R C O N T I N U A T I O N CO M M O N C NC N O R M A L L Y C L O S E D N0 N O R M A L L Y O P E N GC G E N E R A L C O N T R A C T O R ME C H A N I C A L C O N T R A C T O R MCEC E L E C T R I C A L C O N T R A C T O R CO N T R O L S C O N T R A C T O R CCAA V A I R A D M I T T A N C E V A L V E BU I L D I N G C O N T R O L S Y S T E M BC S CO N T I N U A T I O N D E S I G N B U I L D CD B B C BY C O N T R A C T O R CI P C A S T I N P L A C E CO N T R ' R C O N T R A C T O R LI N E A R F O O T LF NE C N A T I O N A L E L E C T R I C C O D E RE Q ' D R E Q U I R E D RE Q ' M T S R E Q U I R E M E N T S SF S Q U A R E F O O T ( F E E T ) IL O I N L I E U O F VE N T T H R U R O O F VT R BE T W E E N B/ N GH X G R O U N D H E A T E X C H A N G E R WI T H R E G A R D T O WR T WA T E R C O O L E D W/ C RE : R E F E R T O : FI R E A L A R M C O N T R O L P A N E L FA C P FF I F O R F U R T H E R I N F O R M A T I O N AH U AS B CH CC CT CV DE F EB H EC U EF F HC HX AI R H A N D L I N G U N I T AI R S E P A R A T O R BO I L E R ( H O T W A T E R ) CH I L L E R CO I L I N G C O I L CO O L I N G T O W E R CO N S T A N T V O L U M E B O X DI S H W A S H E R E X H A U S T F A N EL E C T R I C B A S E B O A R D H E A T E R EV A P O R A T I V E C O O L I N G U N I T EX H A U S T F A N FU R N A C E FA N C O I L FA N P O W E R E D B O X HE A T I N G C O I L HE A T E X C H A N G E R FC FP HU M I D I F I E R KI T C H E N E X H A U S T F A N RE T U R N ( O R R E L I E F ) A I R F A N SU P P L Y F A N VA R I A B L E V O L U M E B O X VA R I A B L E V O L U M E B O X W / R E H E A T H KE F RF SF VV VR UN I T H E A T E R UHEW H E L E C T R I C W A T E R H E A T E R CU H C A B I N E T U N I T H E A T E R GL Y C O L F E E D E R GF WA T E R H E A T E R WH PU M P ( S E E P I P I N G L E G E N D F O R D E T A I L S ) P MI X I N G V A L V E MV TH E R M O S T A T I C M I X I N G V A L V E TM V ET E X P A N S I O N T A N K EQ U I P M E N T A B B R E V I A T I O N S DC D U C T C O I L MA K E - U P A I R U N I T MA U ST O R A G E T A N K STBT B U F F E R T A N K BB B A S E B O A R D SN O W M E L T A R E A SA RA D I A N T Z O N E RZCP C I R C P U M P HP H E A T P U M P MO T O R C O N T R O L C E N T E R MC C SU M P B A S I N SBER U E N E R G Y R E C O V E R Y U N I T 90 ° E L B O W D O W N ( R O U N D D U C T O N L Y ) RO U N D 9 0 ° E L B O W U P ( R O U N D D U C T O N L Y ) OF F S E T T O C H A N G E E L E V A T I O N (A T 3 0 ° W H E N P O S S I B L E ) D = D R O P R = R I S E RO U N D R A D I U S E L B O W 90 ° S T R A I G H T T E E 90 ° C O N I C A L T E E 45 ° B R A N C H 45 ° C O N I C A L T E E SI Z E O R S H A P E T R A N S I T I O N RO U N D F L E X I B L E D U C T 90 ° E L B O W U P ( N E G A T I V E P R E S S U R E ) 90 ° E L B O W U P ( P O S I T I V E P R E S S U R E ) D D 90 ° R A D I U S E L B O W 90 ° R A D I U S E L B O W W / T U R N I N G V A N E S SQ U A R E D U C T S P L I T RO U N D D U C T S P L I T SP L I T B R A N C H T A K E - O F F WI T H S Q U A R E E L B O W & SP L I T T E R D A M P E R SP L I T B R A N C H T A K E - O F F WI T H R A D I U S E L B O W & SP L I T T E R D A M P E R PO S I T I V E P R E S S U R E R I S E R , TY P I C A L L Y S U P P L Y . NE G A T I V E P R E S S U R E R I S E R , TY P I C A L L Y R E T U R N , E X H A U S T O R OU T S I D E A I R . 90 ° E L B O W D N ( N E G A T I V E P R E S S U R E ) 90 ° E L B O W D N ( P O S I T I V E P R E S S U R E ) F/S CO M B I N A T I O N F I R E A N D S M O K E D A M P E R F/S FI R E D A M P E R MO T O R O P E R A T E D D A M P E R ( M O D ) MA N U A L V O L U M E D A M P E R , S I N G L E B L A D E DA M P E R ( S B D ) F O R R O U N D O R < 1 0 " T A L L , OP P O S E D B L A D E D A M P E R ( O B D ) > 1 0 " T A L L . BA C K D R A F T D A M P E R BD D BD D SM O K E D A M P E R SM O K E D E T E C T O R DU C T S I Z E : F I R S T N U M B E R I S P L A N W I D T H , SE C O N D N U M B E R I S D E P T H . 24 x 3 6 24 x 3 6 DU C T W O R K L E G E N D SD SD FL E X RIG I D SN O W M E L T S U P P L Y SN O W M E L T R E T U R N HE A T I N G W A T E R S U P P L Y ( H I G H T E M P ) HE A T I N G W A T E R R E T U R N ( H I G H T E M P ) CH I L L E D W A T E R S U P P L Y CH I L L E D W A T E R R E T U R N CO N D E N S E R S U P P L Y CO N D E N S E R R E T U R N NA T U R A L G A S ME D I U M P R E S S U R E G A S HI G H P R E S S U R E S T E A M S U P P L Y HP C O N D E N S A T E R E T U R N LO W P R E S S U R E S T E A M S U P P L Y LP C O N D E N S A T E R E T U R N RE F R I G E R A N T S U C T I O N RE F R I G E R A N T L I Q U I D DO M E S T I C W A T E R ( D W ) DO M E S T I C H O T W A T E R ( D H W ) DH W R E C I R C U L A T I O N ( D H R ) FI R E L I N E PR E S S U R I Z E D W A S T E PL U M B I N G V E N T P I P E WA S T E P I P E AC I D W A S T E P I P E ST O R M D R A I N P I P E ST O R M D R A I N O V E R F L O W CO M P R E S S E D A I R P I P E GR E A S E W A S T E P I P E AC I D V E N T P I P E LI Q U I D P R O P A N E G A S SE C O N D A R Y D R A I N SA N D A N D O I L W A S T E FL O O R C O O L I N G S U P P L Y FL O O R C O O L I N G R E T U R N PI P I N G D E S I G N A T I O N S PR O P A N E G A S HE A T I N G W A T E R S U P P L Y ( L O W T E M P ) HE A T I N G W A T E R R E T U R N ( L O W T E M P ) SO L A R H E A T I N G W A T E R S U P P L Y SO L A R H E A T I N G W A T E R R E T U R N GR O U N D L O O P S U P P L Y GR O U N D L O O P R E T U R N GR O U N D W A T E R S U P P L Y GR O U N D W A T E R R E T U R N HE A T I N G W A T E R S U P P L Y HE A T I N G W A T E R R E T U R N HY D R O N I C P I P I N G PL U M B I N G P I P I N G DR A I N P I P E FU E L O I L S U P P L Y FU E L O I L R E T U R N GL Y C O L F E E D GR E A S E V E N T NO N - S O F T E N E D D O M E S T I C W A T E R ME D I U M P R E S S U R E S T E A M S U P P L Y MP C O N D E N S A T E R E T U R N FU E L O I L V E N T FU E L O I L F I L L PU M P E D C O N D E N S A T E ST E A M & C O N D E N S A T E P I P I N G GE O T H E R M A L ( O R G R O U N D ) L O O P S U P P L Y GE O T H E R M A L ( O R G R O U N D ) L O O P R E T U R N HE A T I N G W A T E R R E T U R N ( H E A T P U M P ) HE A T I N G W A T E R R E T U R N ( H E A T P U M P ) CL O S E D C O N D E N S E R S U P P L Y CL O S E D C O N D E N S E R R E T U R N PR O P A N E D R A I N PD CC R CC S HW R ( H P ) HW S ( H P ) GL R GL S PC FO F FO V MP R MP S FC R FC S GVD FO R FO S GF HW R HW S GW R GW S GL R GL S SH W R SH W S HW R ( L T ) HW S ( L T ) HW R ( H T ) HW S ( H T ) PG 14 0 ° SM S NS SOSD LP G LP S LP R HP R HP S CA ST ( O F ) STGWAWAVVWPWFRSRLMGGCRCS CH R CH S SM R PR E S S U R E R E D U C I N G V A L V E FL O W S W I T C H SH O C K A B S O R B E R HO S E B I B B ST R A I N E R W / B L O W - O F F V A L V E RO O F D R A I N SA F E T Y R E L I E F V A L V E FL O O R D R A I N FL O O R S I N K HO R I Z O N T A L C L E A N O U T VA C U U M B R E A K E R VE R T I C A L C L E A N O U T PR E S S U R E G A U G E W / P I G T A I L & C O C K TH E R M O M E T E R PR E S S U R E - T E M P . T A P AI R V E N T PI P E A N C H O R FL E X I B L E C O N N E C T O R PI P E E X P A N S I O N J O I N T PI P E U N I O N ST E A M T R A P : DO U B L E C H E C K B A C K F L O W P R E V E N T E R PU M P & E Q U I P M E N T C O N N E C T O R WA L L H Y D R A N T TE M P E R A T U R E C O N T R O L V A L V E ( 2 - W A Y ) DR A I N V A L V E W / H O S E E N D PL U G V A L V E I N R I S E R FL O W B A L A N C I N G V A L V E GA T E O R G L O B E V A L V E I N R I S E R FL O W C O N T R O L V A L V E BA L L V A L V E PL U G O R B A L A N C I N G V A L V E CH E C K V A L V E GL O B E V A L V E BU T T E R F L Y V A L V E VE N T U R I / F L O W I N D I C A T O R PI P I N G S Y M B O L S TE M P E R A T U R E C O N T R O L V A L V E ( 3 - W A Y ) SO L E N O I D V A L V E S TE M P E R A T U R E C O N T R O L L E R O R S E N S O R 90 ° E L B O W U P 90 ° E L B O W D N TE E U P TE E D O W N DE C K / R O O F D R A I N A B O V E SH U T O F F ( B A L L , G A T E , B U T T E R F L Y ) ST E A M T R A P T E S T C H A M B E R FT - F L O A T & T H E R M O S T A T I C TD - T H E R M O D Y N A M I C IB - I N V E R T E D B U C K E T TS - T H E R M O S T A T I C BP - B A L A N C E D P R E S S U R E TCFS W H H B R E F E R E N C E S A M P L E RE : B / M 4 0 0 F F I SH E E T N U M B E R DR A W I N G N U M B E R O R D I A G R A M LE T T E R RE F E R T O : FF I = F O R F U R T H E R I N F O R M A T I O N FC T = F O R C O N T I N U A T I O N FI R E R I S E R DI A G R A M C O N T I N U A T I O N R E F E R E N C E PL U M B I N G R I S E R HE A T I N G W A T E R R I S E R TH E R M O S T A T HV A C R I S E R PO I N T O F D I S C O N N E C T I O N PO I N T O F N E W C O N N E C T I O N SE C T I O N C U T L E T T E R . / SH E E T S H O W N O N . CA R B O N D I O X I D E S E N S O R CA R B O N M O N O X I D E S E N S O R CO N T R O L P A N E L / R A D I A N T M A N I F O L D DU C T S T A T I C P R E S S U R E S E N S O R RO O M P R E S S U R E S E N S O R HU M I D I S T A T RE M O T E T E M P E R A T U R E S E N S O R EM E R G E N C Y P O W E R O F F S W I T C H PL A N S Y M B O L S AC C E S S P A N E L SN O W M E L T M A N I F O L D SP CO 2 EP OPCOHS ----PT --- GENERAL NOTES:M5.0MECHANICAL SCHEDULESM1.6SIXTH FLOOR MECHANICAL PIPING PLAN M1.7PENTHOUSE MECHANICAL PIPING PLANS 1.THESE DRAWING NOTES ACCOMPANY THE PUBLISHED CONSTRUCTION DOCUMENT SPECIFICATION BOOK (PROJECT MANUAL).2.PROVIDE 4” HIGH CONCRETE EQUIPMENT PADS BENEATH FLOOR MOUNTED MECHANICAL EQUIPMENT, IN ADDITION TO ANY BASE ASSEMBLIES REQUIRED OR RECOMMENDED BY THE MANUFACTURER.3.CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE AVAILABLE.4.PROVIDE ¼” GALVANIZED MESH SCREEN ON ALL COMBUSTION AIR DUCTS OR OPENINGS, AND ALL OPEN END RETURN AND EXHAUST DUCTS.5.ALL DUCTWORK DIMENSIONS ARE OUTSIDE SHEET METAL DIMENSIONS. DUCT LINER HAS BEEN ACCOUNTED FOR.6.REFER TO PLUMBING FIXTURE CONNECTIONS SCHEDULE FOR PIPE SIZES TO INDIVIDUAL PLUMBING FIXTURES.7.PROVIDE SHOCK ARRESTERS AT ALL DOMESTIC HOT AND COLD WATER BRANCHES SERVING FIXTURES AND EQUIPMENT WITH QUICK CLOSING VALVES. SUCH FIXTURES AND EQUIPMENT INCLUDES FLUSH VALVE WATER CLOSETS, DISHWASHERS, ICE MACHINES, AND CLOTHES WASHERS. SHOCK ARRESTERS SHALL BE CONSTRUCTED WITH A PISTON IN A SEALED COPPER TUBE CHAMBER, AND APPROVED FOR INSTALLATION WITHIN WALLS WITHOUT ACCESS PANELS. SIOUX CHIEF OR EQUIVALENT. BELLOWS TYPE NOT ACCEPTABLE.8.PROVIDE EXPANSION JOINTS OR LOOPS ON ALL HEATING WATER PIPING RUNS IN EXCESS OF 50 FEET AND IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.9.FILL BOILER SYSTEM WITH 30% PROPYLENE GLYCOL/WATER SOLUTION. REFER TO SPECIFICATIONS FFI.10.FILL SNOWMELT SYSTEM WITH 50% PROPYLENE GYLCOL/WATER SOLUTION.11.GRADE AND VALVE ALL HEATING WATER PIPING WITH 3/4" HOSE END VALVES TO PERMIT COMPLETE DRAINAGE OF THE SYSTEM.VENT ALL HIGH POINTS IN THE EQUIPMENT ROOMS AS NECESSARY WITH AUTOMATIC AIR VENTS PIPED TO A CONVENIENT DRAIN.PROVIDE ALL HIGH POINTS IN SYSTEM OUTSIDE OF EQUIPMENT ROOMS WITH COMBINATION AUTOMATIC/MANUAL AIR VENTS AS REQUIRED TO RELIEVE AIR IN THE SYSTEM.12.EQUIPMENT LABELS: LABEL ALL PIPING AND EQUIPMENT. PROVIDE FULL BAND OR STRIP TYPE MARKERS AND FLOW ARROWS ON PIPING. PROVIDE ENGRAVED PLASTIC VALVE TAGS WITH VALVE NUMBER AND ATTACH WITH STANDARD CHAIN OR S-HOOKS.PROVIDE ENGRAVED PLASTIC SIGN ON OR NEAR SPECIFIED EQUIPMENT. A B O V E S E A L E V E L PR O J E C T A L T I T U D E 8, 1 0 0 ' BOILER FLUE NOTES 1.DUE TO THE AGE OF THE BOILER FLUE, PROVIDE PRESSURE TESTING OF BOILER FLUE TO DETERMINE FLUE CONDITION. FLUE PRESSURE TEST SHALL FOLLOW SMACNA DUCT PRESSURE TEST GUIDELINES FOR 2 INCHES OF STATIC PRESSURE. IF TEST RESULTS DO NOT MEET SMACNA RECOMMENDATIONS, CONTACT OWNER AND ENGINEER IMMEDIATELY AND ANTICIPATE REPLACEMENT OF FLUE.100% CD / PERMIT 03/18/2014 PRE-CONSTRUCTION MEASUREMENTS NOTES 1.PRIOR TO THE START OF ANY DEMOLITION OR EQUIPMENT TO BE PUT OUT OF SERVICE CONTRACTOR SHALL PROVIDE ENGINEER REPORT OF THE FOLLOWING EQUIPMENT.2.ENGINEER WILL ANALYZE PUMP REPORT AND CONFIRM PUMP SELECTIONS WITH SYSTEM OPERATING POINTS. BASIS OF DESIGN PUMPS ARE SCHEDULED BASED ON EXISTING NAMEPLATE INFORMATION ON PUMPS IN THE FIELD AND PREVIOUS DESIGN DOCUMENTATION.3.FOLLOW PROCEDURES IN SPECIFICATION SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PARAGRAPHS 3.5 AND 3.6. PROVIDE PUMP TEST REPORT PER 230593 PARAGRAPH 3.16 E. REFER TO SHEET MD 2.0 AND M2.1 FOR PUMP LOCATIONS IN SCHEMATIC.3.1.(E) P-5SECONDARY BUILDING HEATING WATER PUMP 3.2.(E) P-6SECONDARY BUILDING HEATING WATER PUMP 3.3.(E) (R) P-7SECONDARY PENTHOUSE MUA HEATING WATER PUMP 3.4.(E) (R) P-8SECONDARY PENTHOUSE MUA HEATING WATER PUMP 3.5.(E) P-9 SECONDARY SNOWMELT HEAT EXCHANGER PUMP 3.6.(E) P-10SECONDARY SPA HEAT EXCHANGER PUMP 3.4.(E) P-11SECONDARY SPA HEAT EXCHANGER PUMP 3.4.(E) P-12SECONDARY POOL HEAT EXCHANGER PUMP 3.4.(E) P-13SECONDARY SNOWMELT HEAT EXCHANGER PUMP 3.5.(E) P-DHR-1DOMESTIC HOT RECIRCULATION PUMP 3.5.(E) P-DHR-2DOMESTIC HOT RECIRCULATION PUMP 3.5.(E) P-DHR-3DOMESTIC HOT RECIRCULATION PUMP 3.5.(E) P-DHR-4DOMESTIC HOT RECIRCULATION PUMP 4.PROVIDE TEMPERATURES OF HEATING WATER SYSTEM IN LOCATIONS INDICATED ON SHEET MD 2.0 SYSTEM STARTUP AND FUNCTIONAL TESTING 1.CONTRACTOR SHALL PROVIDE OWNER WITH FUNCTIONAL TESTING REPORTS AND PROVE SYSTEMS CONTROLS DURING CLOSEOUT OWNER TRAINING.M6.0ENLARGED MECHANICAL ROOM SECTION VIEWPARTIAL LOWER LEVEL MECHANICAL PLANM1.1 M0.13544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M01.dwg Printed By: eng-ntt March 18, 2014 - 5:32pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW MECHANICALCOVER SHEET ELEVATOR S LIFT LIFT ROO M LIFT ROOM G 1" 3" 6" HW S HW S HW S HW S HWS HWS HWS HW R HW R HW R HWR HWR HW R HW S 6" 6" 4"4" HWS 6" 2- 1 / 2 " 2- 1 / 2 " 4" 4" 6" 4" 3" 4" G3" 1- 1 / 2 " 2"3/ 4 " GG G 2-1/2" 2-1/2" 3"3" 2- 1 / 2 " 2- 1 / 2 " G 3" 3" 3" 3" 6" 6" 1- 1 / 2 " 3" 3"6" 6" HW S HW R 4" 3" 3" 4" 4" EX I S T I N G PO O L / S P A P U M P S AN D H E A T EX C H A N G E R S T O RE M A I N . PO O L FI L T E R P- 2 P- 1 25 - 1 / 2 x 1 5 - 1 / 2 FL U E D O W N T O BO I L E R , T Y P ( 2 ) . 6" 6" - 4 " R E D U C E R IN R I S E R . AI R S E P A R A T O R GL Y C O L FE E D EX P TA N K AI R CO M P DO M E S T I C H O T WA T E R ST O R A G E TA N K S , T Y P ( 3 ) . P- 6 3" BO I L E R 2 BO I L E R 1 3- W A Y V A L V E I N R I S E R PO O L FI L T E R 2- 1 / 2 " H W S & H W R DO W N T O P - 6 . CH E C K & G A T E VA L V E S I N R I S E R . PI P E S H O W N O F F S E T F O R CL A R I T Y . P I P E R U N S U N D E R AD J A C E N T P I P E . RE M O V E T W O D O M E S T I C WA T E R H E A T EX C H A N G E R S P I P E D I N PA R A L L E L A N D S T A C K E D . 32 x 1 4 F L U E U P IN C H A S E . 40 x 2 0 C A D U C T DO W N T O 1 8 " A. F . F . PO O L FI L T E R 3" D O M E S T I C H W R T O S T ' S . 3" D O M E S T I C H W S T O PL U M B I N G R I S E R S . DI S C O N N E C T A T HE A D E R . W A L L MO U N T E D S U P P L Y AN D R E T U R N P I P I N G TO R E M A I N . DI S A S S E M B L E B O I L E R S FO R R E M O V A L T H R O U G H BO I L E R R O O M E N T R A N C E . CO O R D I N A T E B O I L E R RE M O V A L W I T H AS B E S T O S R E M O V A L CO N T R A C T O R . 2- 1 / 2 " H W S / R FR O M R - 3 . 3" H W S / R FR O M R - 1 . 4" H W S / R FR O M R - 2 . EX I S T I N G A I R C O M P R E S S O R TO R E M A I N I N P L A C E . C A P AN Y P N E U M A T I C C O N T R O L S EQ U I P M E N T R E M O V E D I N DE M O L I T I O N . EX I S T I N G P - 7 A N D 8 TO B E R E L O C A T E D TO L O C A T I O N SH O W N O N N E W WO R K P L A N . EX I S T I N G S N O W M E L T PU M P S A N D H E A T EX C H A N G E R T O RE M A I N . (E ) E F - 1 1 TO ( E ) T F - 1 . 1.TAG AND RETURN TO THE OWNER ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED IN GOOD CONDITION.2.REPORT ANY EXISTING DAMAGED FIXTURES,EQUIPMENT AND/OR DEVICES TO THE OWNER IN WRITING PRIOR TO STARTING ANY WORK.3.COORDINATE EXTENT OF DEMOLITION WITH NEW WORK. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO DEMOLITION.4.DO NOT DISCONNECT OR PUT OUT OF SERVICE ANY SYSTEM WITHOUT COORDINATION WITH THE G.C./OWNER.5.EXISTING CONDITIONS SHOWN FOR REFERENCE.NOT ALL CONDITIONS ARE NECESSARILY SHOWN.NOTES:REMOVE (E) EXHAUST FAN & DUCTWORK. CAP,SEAL AND INSULATE LOUVER PENETRATION THROUGH EXTERIOR WALL.(E) ELEVATOR TRANSFER FAN AND DUCTWORK TO REMAIN. REMOVE DUCTWORK AS NECESSARY TO INSTALL NEW FIRE DAMPERS.1FLAG NOTES:2 2 2 1 EX I S T I N G P O O L / S P A PU M P S A N D H E A T EX C H A N G E R S T O RE M A I N . - OS A 42 x 7 2 - OS A 42 x 7 2 (E ) 3 / 4 " D H C T O P D H R 3/4" MD1.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420MD10.dwg Printed By: eng-ntt March 18, 2014 - 5:24pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW ENLARGED MECHANICAL ROOM DEMOLITION PLAN HW R HW S HW S HW R HWRHWS 6"HWS 6" HW S 6"HWS 6"HWR 6" HW R 6" HW R 6"HWR 1-1/2" 6"HWS 6"HWS 6"HWS 6"HWS 6" HW S 4" 4" 4" 1"1" 2" 2" 1" 6" 6" 6" 3"HWS2-1/2"HWS2"HWS1-1/2"HWS 1-1/2"HWR 2"HWR 2-1/2"HWR 3"HWR 2"2"6"HWS 2- 1 / 2 " 3"HWS2-1/2"HWS2"HWS1-1/4"HWS 1-1/4"HWR 2"HWR 2-1/2"HWR 3"HWR 1-1/2" P- 1 P- 2 P- 6 P - 5 P- 7 P-8 HX - 1 HX - 2 P- 3 P - 4 P- 9 P-11P-10 BO I L E R 1 BO I L E R 2 TO M U A U N I T S IN P E N T H O U S E WE S T R I S E R EA S T R I S E R FI R S T F L O O R . SE C O N D F L O O R . TH I R D F L O O R . FO U R T H F L O O R . FI F T H F L O O R . SI X T H F L O O R . AT T I C L E V E L . TO ADULT SPA HX-5.TO POOL HX-6. TO S N O W M E L T H X - 4 . TO S P A H X - 3 . DH W H X , T Y P 2 . SC A L E : ME C H A N I C A L W A T E R F L O W D E M O L I T I O N D I A G R A M NO N E P-12 P- 1 3 MEASURE AND RECORD EXISTING PUMPING SYSTEMS WHILE IN SERVICE PRIOR TO DEMOLITION PER SPECIFICATION. RE: PRE CONSTRUCTION MEASUREMENT NOTES ON M0.1.MEASURE AND RECORD SYSTEM TEMPERATURE AT LOCATION IN SYSTEM.1FLAG NOTES:2 2 2 2 2 2 1 1 1 1 1 111 1 2 2 MD2.0MECHANICAL WATER FLOW DEMOLITION DIAGRAM3544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420MD20.dwg Printed By: eng-ntt March 18, 2014 - 5:24pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW (E ) P O O L FI L T E R 2-1/2" HWS(E ) P O O L FI L T E R PO O L E Q U I P M E N T PO T FE E D E R (E ) P O O L EQ U I P M E N T 4" G 1 5" HWS DOWN TO BOILER TYP, 3. (E ) 1 " D H C (E ) 4 " H W R (E ) 4 " H W S 5" HWR DOWN TO BOILER TYP, 3. 1 (E) 3/4" DHC (E ) 4 " G 2-1/2" 1 (E) CW (E) CW IN S T A L L V F D M O T O R S ON ( E ) ( R ) P - 7 , P - 8 . 7 VFD 3" HWR 3" HWS (E) AIR COMPRESSOR. VFD P- 7 A N D P - 8 V F D s . EP O P- 5 A N D P - 6 V F D s . VFD (N ) S T A C K E D VE R T I C A L L Y . VFD 4 (N) TEMPERATURE CONTROL PANEL. 2 9 2 SC A L E : EN L A R G E D M E C H A N I C A L R O O M P L A N 1/ 2 " = 1 ' - 0 " TO (E) TF-1.1.DO NOT SCALE DRAWINGS. VERIFY DIMENSION IN FIELD PRIOR TO COMMENCEMENT OF WORK.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.2.SUBCONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY G.C./ENGINEER OF DISCREPANCIES PRIOR TO STARTING ANY WORK.3.TAG AND RETURN TO THE OWNER ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED IN GOOD CONDITION.4.REPORT ANY EXISTING DAMAGED FIXTURES,EQUIPMENT AND/OR DEVICES TO THE OWNER IN WRITING PRIOR TO STARTING ANY WORK.5.DO NOT DISCONNECT OR PUT OUT OF SERVICE ANY SYSTEM WITHOUT COORDINATION WITH THE G.C./OWNER.6.PATCH AND REPAIR ALL INSULATION ON PIPING AND DUCTWORK DAMAGED DURING REMOVAL AND INSTALLATION OF EQUIPMENT.7.ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILING IN ACCESSIBLE LOCATIONS OR WITH ACCESS PANELS IN HARD-LID CEILINGS. 9 6NOTES:HWS/R TO (E) SNOWMELT & POOL EQUIPMENT. RE:M2.0 FFI.PROVIDE (N) DEEP SEAL TRAP AT BOTTOM OF FLUE STACK. PROVIDE (N) DEEP TRAP AT BOTTOM OF FLUE STACK. PROVIDE TRAP PRIMER & EXTEND TO NEAREST FLOOR SINK.G DN. TO BURNER.(E) LOUVER AND DUCT TO REMAIN.RE: M1.1 FCT.PROVIDE (N) 2HR DUCT WRAP FOR SEPARATION OF BOILER FLUE FROM ELEVATOR MACHINE ROOM.PROVIDE PANIC HARDWARE & EPO AT BOILER ROOM EXIT.BOILER FLUES TO BE ROUTED ABOVE PIPING. FLUES SHOWN BELOW FOR GRAPHICAL QUALITY OF PIPING SYSTEM.FIRE DAMPER EXISTING AIR COMPRESSOR TO REMAIN. CAP AND SEAL ALL REMOVED PNEUMATIC CONTROL LINES.DOMESTIC HOT WATER TEMPERING VALVE AND HOT WATER CIRCULATION PUMP STATION MOUNTED ON UNISTRUT. RE: M-2.1 FFI.1FLAG NOTES: BA R O M E T R I C P R E S S U R E DA M P E R I N V E R T I C A L TE E , T Y P 3 . 2 3 4 5 6 7 8 9 (E) 34x16 FLUE 10 10 4 (E ) P O O L A N D S N O W M E L T HE A T E X C H A N G E R S (N) 14 "ø FLUE (N ) 1 0 x 1 4 F L U E 6" H W S 5" H W S 4" G 6" H W R 5" H W R 11 11 _" _"(E ) P O O L FIL T E R (E ) S N O W M E L T . 5" HWS 120°F DHW DCW HWS2" 3" HWS HW R 3" H W R HWS 5" HWR 4" H W R 6" H W S 4"HWS 2- 1 / 2 " HW R 2- 1 / 2 " 3/ 4 " 14 0 ° F D H R 3/ 4 " 14 0 ° F D H W 4" H W R 3" 2" 1- 1 / 2 " 2- 1 / 2 " 2" 1- 1 / 2 " 3" CW 3" 4" HW R DH C 3" 120°F DHW 1-1/2" 120°F DHR 140°F DHW 140°F DHR 3" D N . T O WH T Y P , 4 . - OS A 42 x 7 2 - OS A 42 x 7 2 DH W HW R 3" DH C 3" DH W HW S 4" HW R 3 3 3 4" H W S 2-1/2" HWR 3" CW 3"CW 2-1/2" HWS 5" H W S 3" HWS 4" H W S 5" H W R 5" H W S 2" 3" HWR HW R 2" 3" HWR (E ) 3 / 4 " D H C . 5 55(E) ELECTRICAL PANELS AND DISCONNECTS. RE:ELEC FFI. 8 8 8 1 M6 . 0 1 M6 . 0 M1.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M10.dwg Printed By: eng-ntt March 18, 2014 - 5:24pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW ENLARGED MECHANICAL ROOM PLAN 1.DO NOT SCALE DRAWINGS. VERIFY DIMENSION IN FIELD PRIOR TO COMMENCEMENT OF WORK.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.2.SUBCONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY G.C./ENGINEER OF DISCREPANCIES PRIOR TO STARTING ANY WORK.3.TAG AND RETURN TO THE OWNER ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED IN GOOD CONDITION.4.REPORT ANY EXISTING DAMAGED FIXTURES,EQUIPMENT AND/OR DEVICES TO THE OWNER IN WRITING PRIOR TO STARTING ANY WORK.5.DO NOT DISCONNECT OR PUT OUT OF SERVICE ANY SYSTEM WITHOUT COORDINATION WITH THE G.C./OWNER.6.PATCH AND REPAIR ALL INSULATION ON PIPING AND DUCTWORK DAMAGED DURING REMOVAL AND INSTALLATION OF EQUIPMENT.7.ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILING IN ACCESSIBLE LOCATIONS OR WITH ACCESS PANELS IN HARD-LID CEILINGS.NOTES:EXISTING DOMESTIC COLD/HOT WATER TO KITCHEN FIXTURES. EXACT ROUTING AND PIPE SIZES NOT KNOWN. CONTRACTOR TO PERFORM SELECTIVE DEMOLITION IN ORDER TO DETERMINE PIPE ROUTES.REMOVE (E) HOT WATER CONNECTION TO BRANCH.CAP (E) TAKE-OFF. PROVIDE (N) ISOLATION VALVE AT CONNECTION AND CONNECT (N) 1" 140°F DHW TO PIPING SERVING KITCHEN.CONNECT (N) 1/2" DHC TO FURTHEST FIXTURE IN KITCHEN AND AT (N) TIE-IN LOCATION.DHW AND RECIRC ROUTING TO RESTAURANT BAR UNKNOWN. CONTRACTOR TO EXTEN 140°F DHW TO BAR.1FLAG NOTES:2 SC A L E : PA R T I A L L O W E R L E V E L M E C H A N I C A L P L A N 3/ 1 6 " = 1 ' - 0 " HW S / R T O R I S E R S 3/ 4 " 3/ 4 " D H C F R O M P13 2-1/2"HWS 2-1/2"HWR 3"DCW DHW HWS HWR 3" 3" 3" 2- 1 / 2 " DC W DH W 2- 1 / 2 " 1" 1" D H C U P T O 1" D H C U P T O P 19 14 0 D H W 14 0 D H W 3 3 3 4 4 14 0 D H W DH C DH W 14 0 D H W P25 2 DC W DH W 1 1 P 24 4 P20 P20 M1.13544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M11.dwg Printed By: eng-ntt March 18, 2014 - 5:25pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW PARTIAL LOWER LEVEL MECHANICAL PLAN BALCONY BALCONY BALCONY BALCONY BALCONY BALCONY BALCONY BALCONY BALCONY BALCONY PATIO PATIO PATIO PATIO PATIO ELEVATORS G.C.E. HALL DN ATRIUM DN DN 2- 1 / 2 " H W S A N D H W R RI S E R T O M U A U N I T S AB O V E . 1/ 1 - 4 " H W R R I S E R . 1- 1 / 4 " H W S R I S E R . 1- 1 / 4 " H W S A N D H W R T O 6T H F L O O R B A S E B O A R D HE A T E R S . R 1 R 3 1- 1 / 2 " H W R R I S E R . 1- 1 / 2 " H W S R I S E R . 1- 1 / 2 " H W S A N D H W R T O 6T H F L O O R B A S E B O A R D HE A T E R S . R 2 SC A L E : SI X T H F L O O R M E C H A N I C A L P I P I N G P L A N 1/ 8 " = 1 ' - 0 " PROVIDE NEW DIFFERENTIAL PRESSURE TRANSDUCER IN DUCT CHASE. EXTENT OF CEILING AND WALL DEMOLITION REQUIRED TO ACCESS PIPING HAS NOT YET BEEN DETERMINED.(E) BOILER FLUE UP TO ROOF. PROVIDE (N)RAIN CAP PER IFGC. INSPECT FLUE TO VERIFY CONDITION SUITABLE FOR CONTINUED SERVICE.1FLAG NOTES:1.DO NOT SCALE DRAWINGS. VERIFY DIMENSION IN FIELD PRIOR TO COMMENCEMENT OF WORK.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.2.SUBCONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY G.C./ENGINEER OF DISCREPANCIES PRIOR TO STARTING ANY WORK.3.TAG AND RETURN TO THE OWNER ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED IN GOOD CONDITION.4.REPORT ANY EXISTING DAMAGED FIXTURES,EQUIPMENT AND/OR DEVICES TO THE OWNER IN WRITING PRIOR TO STARTING ANY WORK.5.DO NOT DISCONNECT OR PUT OUT OF SERVICE ANY SYSTEM WITHOUT COORDINATION WITH THE G.C./OWNER.6.PATCH AND REPAIR ALL INSULATION ON PIPING AND DUCTWORK DAMAGED DURING REMOVAL AND INSTALLATION OF EQUIPMENT.7.ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILING IN ACCESSIBLE LOCATIONS OR WITH ACCESS PANELS IN HARD-LID CEILINGS.NOTES: 1 1 2 2 M1.63544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M16.dwg Printed By: eng-ntt March 18, 2014 - 5:25pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW SIXTH FLOOR MECHANICAL PIPING PLAN CORRIDOR MUA SUPPLY AND EXHAUST AIR RISERS. 1- 1 / 2 " H W R EX H A U S T R I S E R S 3/ 4 " H W S O P E N E N D E D . 2- 1 / 2 " H W S / R D N . EF - 2 (E ) R H - 2 (E ) R H - 1 (E) RH-3 SC A L E : 1 WE S T P E N T H O U S E M E C H A N I C A L P I P I N G P L A N NO N E (E ) C O R R I D O R M U A S U P P L Y AN D E X H A U S T A I R R I S E R S . (E ) C O R R I D O R M U A S U P P L Y AN D E X H A U S T A I R R I S E R S . (E ) 2 " H W S / R DN . I N W A L L . (E ) C O R R I D O R M U A S U P P L Y AN D E X H A U S T A I R R I S E R S . SC A L E : 2 EA S T P E N T H O U S E M E C H A N I C A L P I P I N G P L A N NO N E 1 1.DO NOT SCALE DRAWINGS. VERIFY DIMENSION IN FIELD PRIOR TO COMMENCEMENT OF WORK.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.2.SUBCONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY G.C./ENGINEER OF DISCREPANCIES PRIOR TO STARTING ANY WORK.3.TAG AND RETURN TO THE OWNER ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED IN GOOD CONDITION.4.REPORT ANY EXISTING DAMAGED FIXTURES,EQUIPMENT AND/OR DEVICES TO THE OWNER IN WRITING PRIOR TO STARTING ANY WORK.5.DO NOT DISCONNECT OR PUT OUT OF SERVICE ANY SYSTEM WITHOUT COORDINATION WITH THE G.C./OWNER.6.PATCH AND REPAIR ALL INSULATION ON PIPING AND DUCTWORK DAMAGED DURING REMOVAL AND INSTALLATION OF EQUIPMENT.7.ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILING IN ACCESSIBLE LOCATIONS OR WITH ACCESS PANELS IN HARD-LID CEILINGS.NOTES:PROVIDE NEW DIFFERENTIAL PRESSURE TRANSDUCER IN PIPING UPSTREAM OF BRANCH TO EACH MAKE UP AIR UNIT. EXTENT OF CEILING AND WALL DEMOLITION REQUIRED TO ACCESS PIPING HAS NOT YET BEEN DETERMINED.1FLAG NOTES: 1 1 M1.73544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M17.dwg Printed By: eng-ntt March 18, 2014 - 5:25pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW PENTHOUSE MECHANICAL PIPING PLANS HW R HW S HW S HW R HW R HWS 1"1"2"1" 3"HWS2-1/2"HWS2"HWS1-1/2"HWS 1-1/2"HWR 2"HWR 2-1/2"HWR 3"HWR 2" 2" 3"HWS2-1/2"HWS2"HWS1-1/4"HWS 1-1/4"HWR 2"HWR 2-1/2"HWR 3"HWR 1- 1 / 2 " TO M U A U N I T S IN P E N T H O U S E . WE S T R I S E R . EA S T R I S E R . FI R S T F L O O R . SE C O N D F L O O R . TH I R D F L O O R . FO U R T H F L O O R . FI F T H F L O O R . SI X T H F L O O R . AT T I C L E V E L . TO P O O L H X - 6 . TO SNOWMELT HX-4.TO SPA HX-3. DP T DP T DP T D S LI N E S I Z E SP I R O V E N T AI R - D I R T SP E R A T O R . (N ) E T - 1 TO A D U L T S P A H X - 5 . SC A L E : ME C H A N I C A L W A T E R F L O W D I A G R A M NO N E 26 . 9 G P M 16 . 2 G P M 20 . 9 G P M 20 . 9 G P M 20 . 9 G P M 22 . 6 G P M 15 . 2 G P M 15 . 2 G P M 15 . 2 G P M 15 . 2 G P M 15 . 2 G P M 12 . 5 G P M D S D S TO S P A H X - 8 . 2" 6" H W S 6" H W S 6" H W R 2- 1 / 2 " H W R 2- 1 / 2 " H W S 5" H W R 5" H W S 5" HWR 5" HWS3" HWR (N ) E T - 2 4" HWR 4" H W R 4" 3" H W R 3" H W S 5" HWS6" HWR 6" HWS 4" H W S PR O V I D E N E W IS O L A T I O N VA L V E S A T RI S E R S . D D D D 4" C O N C R E T E P A D , T Y P . AIR VENTS AT ALL HIGH POINTS.M2.0MECHANICAL WATER FLOW DIAGRAM3544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M20.dwg Printed By: eng-ntt March 18, 2014 - 5:26pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW SC A L E : 1 ME C H A N I C A L D O M E S T I C W A T E R F L O W D E M O L I T I O N D I A G R A M NO N E HX - 1 HX - 2 (E ) S T - 1 20 0 G A L (E ) S T - 1 20 0 G A L (E ) S T - 1 20 0 G A L SC A L E : 2 ME C H A N I C A L D O M E S T I C W A T E R F L O W D I A G R A M NO N E P- 1 4 P - 1 5 (E ) P - D H R - 1 ( E ) P - D H R - 3 (E ) P - D H R - 2 ( E ) P - D H R - 4 12 0 ° AS M E R A T E D D I A P H R A G M , TY P E E X P A N S I O N T A N K SU I T E D F O R P O T A B L E WA T E R D U T Y . 1 5 G A L M I N . 10 G A L A C C E P T A N C E M I N . AM T R O L S T - 4 2 V - C O R EQ U I V . (N ) S I N G L E S T A T I O N T H E R M O S T A T I C MI X I N G V A L V E . 2 6 M A X G P M , 1 G P M MI N . S E T T O 1 4 0 ° F M I X TE M P E R A T U R E . P I P E P E R MA N U F A C T U R E S I N S T R U C T I O N S . 14 0 ° EXTEND NEW 140 DEG F DOMESTIC HOT WATER TO KITCHEN.EXISTING DOMESTIC HOT WATER TO RISERS TO BE RE-LABELED AS 120 DEG F DOMESTIC HOT WATER.(N) (N ) (N ) D U A L S T A T I O N T H E R M O S T A T I C MI X I N G V A L V E . 7 5 M A X G P M , 6 G P M MI N . S E T T O 1 2 0 ° F M I X TE M P E R A T U R E . P I P E P E R MA N U F A C T U R E S I N S T R U C T I O N S . EXISTING DOMESTIC COLD WATER SERVICE AND BACKUP.EXISTING DOMESTIC COLD WATER SERVICE AND BACKUP. TH E R M O M E T E R M U S T B E T I E D I N AF T E R R E T U R N L I N E T I E D I N . EXTEND NEW 140 DEG F CIRCULATION TO KITCHEN. (N ) EXISTING DOMESTIC HOT WATER RECIRC LOOPS. RE M-1.0 FOR NEW TIE IN LOCATIONS. EX I S T I N G D O M E S T I C HO T W A T E R R E C I R C LO O P S . R E M - 1 . 0 F O R NE W T I E I N L O C A T I O N S . RE: HORIZONTAL INLINE PUMP DIAGRAM FOR APPURTENANCES REQUIRED. TYP 3. PDHR. EX I S T I N G D O M E S T I C HO T W A T E R T O R I S E R S . TC RE : M 4 . 0 F O R D H W T E M P E R A T U R E SE N S O R A N D E M E R G E N C Y I S O L A T I O N VA L V E . 1FLAG NOTES:PROVIDE FLOW AND PRESSURE OF EXISTING PUMPING SYSTEMS WHILE IN SERVICE PRIOR TO DEMOLITION. RE: PRE CONSTRUCTION MEASUREMENT NOTES ON M0.1 1 1 1 1 M2.1SHEET TITLE:3544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M21.dwg Printed By: eng-ntt March 18, 2014 - 5:26pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW MECHANICAL DOMESTIC WATER FLOW DIAGRAMS FIRE DAMPER AND FIRE/SMOKENO LINING REQ'D.CONCRETE OR MASONRYMETAL STUD NO SCALEWOOD STUDRECOMMENDED MIN. SLEEVE THICKNESS 85" UP55"-84"31"-54"182022BREAKAWAY13"-30"12" DN 2426 .036".047".030".024".018"NOTES:DAMPER ASSEMBLY DIAGRAMWALL.RETAINING ANGLE.CLOSURE DETAIL.RECESSED DAMPER AND LINKAGE ASSEMBLY OUT OF AIRSTREAM.DAMPER FRAME.SHEET METAL DUCT.BREAKAWAY DUCT CONNECTION.FIRE RESISTIVE MATERIAL.ANGLE.SLEEVE.CONNECTION CONNECTION CONNECTIONOPENING TO BE LINED WITH FIRE RESISTIVE MATERIAL OF RATING EQUAL TO THAT ON THE WALL.NO LINING WITH SOLID METAL STUD FRAMING.1.PROVIDE ACCESS PANELS AS REQUIRED.2.THIS DIAGRAM IS NOT INTENDED TO COVER ALL CASES OF FIRE DAMPER AND FIRE/SMOKE DAMPER INSTALLATION.BY U.L. STANDARD 555 ALL DUCTS ARE REQUIRED TO TERMINATE AT SLEEVES OR DAMPER FRAMES. SLEEVE THICKNESS IS CONTINGENT ON TYPE OF CONNECTION. ALL U.L. LISTED DAMPERS ALSO HAVE MAX.DIMENSIONS ASSOCIATED WITH THE TEST RATING.HOWEVER SLEEVE THICKNESS MUST ALSO NOT BE LESS THAN DUCT GAGE OR THAT SPECIFICALLY AUTHORIZED BY A RECOGNIZED AUTHORITY.TYPE OF CONNECTIONDUCT DIM.IN DIA. OR RECTANGULARSLEEVEGAGEMIN. SLEEVE THICKNESS UNCOATED STEELCOATEDSTEELWALL SLEEVE. PI P E H A N G E R S . P R O V I D E D O U B L E DE F L E C T I O N N E O P R E N E T Y P E F O R FI R S T T W O O N E A C H S I D E O F P U M P . MO U N T M O T O R SH A F T I N OR I E N T A T I O N PE R M F G ' S RE C O M M E N D A T I O N . NO T E : SU P P O R T P U M P F R O M P I P I N G O N L Y . D O NO T S U P P O R T P U M P F R O M M O T O R , UN L E S S H A N G E R I S BU I L T I N . M O U N T P U M P PE R M A N U F . R E C O M M E N D A T I O N S . DI R E C T I O N O F WA T E R F L O W . HO R I Z O N T A L I N L I N E PU M P D I A G R A M NO S C A L E AI R C O N T R O L D I A G R A M D HWS NO S C A L E HWS AM T R O L 7 2 0 S E R I E S F L O A T VE N T , O R E Q U I V . AI R S E P A R A T O R . S U P P O R T AS R E Q ' D . TO P U M P TO G L Y C O L F E E D E R . S E E DI A G R A M , T H I S S H E E T DI A P H R A G M E X P A N S I O N TA N K IN D I R E C T TO F . D . 34" TY P I C A L H A N G E R D I A G R A M NO S C A L E PI P E I N S U L A T I O N WI T H S H I E L D A N D IN S E R T . SCALE:END SUCTION PUMP ASSEMBLY NONEPARALLEL BASE MOUNTEDNOT USED.PIGTAIL PRESSURE GAUGE. TYP. GAUGE FEEDS TO BE 1/2".INDIRECT CONNECT TO FLOOR SINK RECEPTOR.PIPING TO SLOPE CONTINUOUSLY TO DRAIN OUTLET WITHOUT PIPING BELLIES OR HIGH POINTS. DO NOT COMBINE DRAINS.PROVIDE 4" HIGH SHOP KEEPING PAD FOR ALL FLOOR MOUNTED EQUIPMENT IN ADDITION TO MFG'S BASE.FLAG NOTES:PROCESS WATER RETURN FROM LOAD.FROM CHEMICAL POT FEEDER.FLEXIBLE PUMP CONNECTOR, TYP.SUCTION DIFFUSER,TYP.SEPARATE DEVICES REQ'D. TRIPLE-DUTY VALVE NOT PERMITTED.1.GROUT BASE-MOUNTED PUMPS AFTER ALIGNMENT.2.PUMP CONNECTION SPECIALTIES (VALVING,FLEXIBLE CONNECTORS, STRAINER, ETC) SHALL BE NO SMALLER THAN PIPE SIZE INDICATED ON PIPING DIAGRAMS. INSTALL PIPE SIZE TRANSITION FITTING AT PUMP CONNECTION.3.SUCTION DIFFUSER OUTLET SIZE TO BE EQUAL TO PUMP SUCTION SIZE. INLET SIZE SHALL BE EQUAL TO PIPE SIZE NOTED ON PIPING DIAGRAMS.NOTES: PA R A L L E L P U M P S S H A L L B E AR R A N G E D I N T R U E R E V E R S E RE T U R N F A S H I O N W I T H E Q U A L LE N G T H D R O P S T O E A C H DE V I C E . D I S C H A R G E TH R O T T L I N G V A L V E N O T PE R M I T T E D . PR O C E S S W A T E R SU P P L Y T O L O A D . TO C H E M I C A L P O T FE E D E R . INERTIA BASE,TYP.D D D D324 4332 3 1 2 3 4 AN C H O R D I A G R A M PI P E G U I D E & NO S C A L E VA R I E S WE L D G U I D E A S R E Q U I R E D TO M O U N T I N G P L A T E . PI P E G U I D E ; I T T G R I N N E L L FI G U R E 2 5 5 O R A P P R O V E D EQ U I V A L E N T . WA L L PI P E A N C H O R ; 5 / 8 " X 1 1 " P L WE L D E D C O N T I N U O U S L Y T O PI P E & M O U N T I N G P L A T E . MO U N T I N G P L A T E . DI A G R A M GL Y C O L F E E D E R NO SCALE SC A L E : IN L I N E P U M P D I A G R A M NO N E PA R A L L E L S T A C K E D V E R T I C A L NO T U S E D . PI G T A I L P R E S S U R E G A U G E . T Y P . G A U G E F E E D S T O BE 1 / 2 " . IN D I R E C T C O N N E C T T O F L O O R S I N K R E C E P T O R . PI P I N G T O S L O P E C O N T I N UO U S L Y T O D R A I N O U T L E T WI T H O U T P I P I N G B E L L I E S O R H I G H P O I N T S . D O N O T CO M B I N E D R A I N S . PR O V I D E 4 " H I G H S H O P K E E P I N G P A D F O R A L L FL O O R M O U N T E D EQ U I P M E N T I N A D D I T I O N T O MF G ' S B A S E . FL A G N O T E S : 1. P R O V I D E S U F F I C I E N T H E I G H T F O R R E M O V A L O F BO T T O M P U M P W H I L E U P P E R P U M P R E M A I N S I N OP E R A T I O N . 2. P U M P C O N N E C T I O N S P E C I A L T I E S ( V A L V I N G , FL E X I B L E C O N N E C T O R S , S T R A I N E R , E T C ) S H A L L BE N O S M A L L E R T H A N P I P E S I Z E I N D I C A T E D O N PI P I N G D I A G R A M S . I N S T A L L P I P E S I Z E TR A N S I T I O N F I T T I N G A T P U M P C O N N E C T I O N . NO T E S : 1 2 3 4 IN L I N E P U M P S S T A C K E D V E R T I C A L L Y . CH E M I C A L P O T F E E D E R . 2 2 D 3 D 3 CG H D E F B A M3.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M30.dwg Printed By: eng-ntt March 18, 2014 - 5:26pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW MECHANICALDIAGRAMS ANALOG INPUT TO BCSCONTROLS SYMBOLS TEMP SENSORAIAOBIBOANALOG OUTPUT FROM BCS BINARY INPUT TO BCS BINARY OUTPUT FROM BCS CARBON MONOXIDE SENSORCARBON DIOXIDE SENSOR CURRENT SWITCH FLOW SWITCH HUMIDITY SENSOR MOTOR STARTER DAMPER MOTOR RELAY SMOKE DETECTOR TEMPERATURE SENSOR VARIABLE FREQUENCY DRIVECPFREEZESTATSENSOR-THERMOSTAT SWITCH SPACE MOUNTED STATEQUIPMENT MANUFACTURER'S CONTROL PANEL DIFFERENTIAL PRESSURE SWITCHDIFFERENTIAL PRESSURE TRANSDUCER FLOW SENSORAIRFLOW MEASURING STATIONAFMS COCO2 CS DPSDPT FRZFSF HE MSDM RLY S SMK TE TSTAT VFDPRESSURE SENSORPEMOTOR (FAN, DAMPER OR OTHER) MEMERGENCY POWER OFFEPO EMERGENCY VENTILATION ONEVO CO N T R O L S G E N E R A L N O T E S : 1. L i g h t l i n e w e i g h t i n d i c a t e s e x i s t i n g c o n t r o l s c o m p o n e n t s & p o i n t s o n BA S . H e a v y l i n e w e i g h t a n d p r e - s c r i p t ' ( N ) ' i n d i c a t e s n e w c o n t r o l s co m p o n e n t s r e q u i r e d f o r f r e e c o o l i n g & c h a n g e - o v e r s e q u e n c e s o f op e r a t i o n . 2. T h e s e d o c u m e n t s d e p i c t t h e e n g i n e e r ' s u n d e r s t a n d i n g o f c o n t r o l s co m p o n e n t ' s c u r r e n t l y e x i s t i n g . D u ri n g p r i c i n g , c o n t r o l s c o n t r a c t o r sh a l l b e r e s p o n s i b l e t o c o n f i r m t h e s e c o m p o n e n t s e x i s t a n d i n c l u d e co s t t o a d d i f f o u n d n o t t o e x i s t . A l l c o n t r o l s c o m p o n e n t s s h o w n (i n c l u d i n g t h o s e n o t e d a s e x i s t i n g ) a r e r e q u i r e d t o a c h i e v e t h e se q u e n c e s o f o p e r a t i o n . 3. C o n t r o l s c o n t r a c t o r t o c o v e r a l l c o s t s o f e l e c t r i c a l p o w e r r e q u i r e m e n t s , if a n y , a n d l i n e v o l t a g e w i r i n g , i f a n y , b y l i c e n s e d e l e c t r i c i a n . 4. S e q u e n c e s o f o p e r a t i o n d e f i n e d h e r e i n d e s c r i b e g e n e r a l i n t e n t a n d d o no t i n c l u d e a l l n e c e s s a r y p r o c e d u r e s / s t e p s r e q u i r e d . A n t i c i p a t e f i n e tu n i n g o f s e q u e n c e s ( i n c l u d i n g , b u t n o t l i m i t e d t o , s e t p o i n t ad j u s t m e n t s , d e a d b a n d r e f i n e m e n t , r e se t c u r v e s e n d p o i n t s , t i m e de l a y s , o f f s e t s , a n d a c t u a l s e q u e n c i n g o f e q u i p m e n t ) , m a y b e re q u i r e d a n d s h a l l b e p e r f o r m e d i n c l o s e c o o r d i n a t i o n w i t h t h e co m m i s s i o n i n g a g e n t w i t h e n g i n e e r i n g o v e r s i g h t a s r e q u i r e d d u r i n g fu n c t i o n a l p e r f o r m a n c e t e s t i n g o f t he s y s t e m s . C o n t r o l s c o n t r a c t o r sh a l l b e r e s p o n s i b l e t o m a k e a n y a n d a l l f i n e t u n i n g a d j u s t m e n t s t o pr o v i d e a c o m p l e t e a n d o p e r a b l e s y s t e m . 5. C o n t r o l s s y s t e m c o m p o n e n t s s h a l l b e c o m p a t i b l e w i t h e x i s t i n g bu i l d i n g a u t o m a t i o n s y s t e m . C o n t r o l s s h a l l b e f i e l d i n s t a l l e d . Co n t r o l s c o n t r a c t o r s h a l l b e r e s p o n s i b l e f o r w i r i n g a n d i n s t a l l i n g a l l de v i c e s r e q u i r e d f o r a f u l l y f u n c t i o na l c o n t r o l s y s t e m f o r t h i s p r o j e c t , re g a r d l e s s o f v o l t a g e . I f t h e c on t r a c t o r c a n n o t s e l f p e r f o r m w o r k re q u i r i n g l i n e v o l t a g e t h e n t h e c o n t r a c t o r s h a l l c o o r d i n a t e w i t h a n d co m p e n s a t e t h e e l e c t r i c a l c o n t r a c t o r as r e q u i r e d . C o n t r o l s c o n t r a c t o r sh a l l c o o r d i n a t e w i t h e q u i p m e n t s u p p l i e r s t o e n s u r e t h a t a l l d e v i c e s ar e c o m p a t i b l e w i t h t h e e x i s t i n g c o n t r o l s s y s t e m a n d e x i s t i n g me c h a n i c a l e q u i p m e n t . C o n t r o l s c o n t r a c t o r s h a l l p r o v i d e r e a d - o n l y ac c e s s t o t h e B A S v i a t h e i n t e r n e t f o r a p e r i o d o f o n e y e a r t o a s s i s t wi t h t r o u b l e s h o o t i n g a n y i s s u e s r e l a te d t o t h e H V A C s y s t e m i n t h e ar e a o f t h i s p r o j e c t . 6. A l l c o n t r o l w i r i n g t o b e i n s t a l l e d i n p l e n u m r a t e d c o n d u i t . 7. N o n e t w o r k e d c o n t r o l p o i n t s a r e a l l o w e d . A l l s e n s o r s t o b e h a r d w i r e d di r e c t l y t o c o n t r o l l i n g m o d u l e . DE S C R I P T I O N - T h e p r o j e c t s c o p e c o ns i s t s o f p r o v i d i n g n e w c o n t r o l s sy s t e m s f o r n e w e q u i p m e n t a s w e l l a s r e v i s i o n s t o p r og r a m m i n g c u r r e n t l y co n t r o l l i n g e x i s t i n g h e a t i n g p l a n t e q u i p m e n t . A. P r o v i d e n e w c o n t r o l h a r d w a r e a n d i n f r a s t r u c t u r e f o r e x i s t i n g eq u i p m e n t t h a t r e q u i r e s n e w s e q u e n c e s o f c o n t r o l t o p r o p e r l y in t e g r a t e w i t h t h e n e w h e a t i n g w a t e r p l a n t . Al l n e w B u i l d i n g A u t o m a t i o n S y s t e m ( B A S ) c o n t r o l s e q u i p m e n t , d e v i c e s , an d c o m m u n i c a t i o n s p r o t o c o l s h a l l b e A S H R A E s t a n d a r d 1 3 5 c o m p l i a n t (B A C n e t c o m p a t i b l e ) . RE M O T E A C C E S S - P r o v i d e r e m o t e a c c e s s v i a w e b b a s e d i n t e r f a c e ( w e b ac c e s s i t s e l f i s n o t p a r t o f t h i s c o n t r a c t ) . R e m o t e a c c e s s s h a l l h a v e , a t a mi n i m u m , t h e f o l l o w i n g v a r i o u s l e v e l s o f c o n t r o l c a p a b i l i t y b a s e d o n cr e d e n t i a l s p r o v i d e d d u r i n g l o g - i n : Le v e l 1 - V i e w o n l y : F u l l v i e w i n g N o a d j u s t m e n t c a p a b i l i t i e s . P r o v i d e 'v i e w o n l y ' r e m o t e a c c e s s l o c a t i o n a n d c r e d e n t i a l s t o e n g i n e e r a n d co m m i s s i o n i n g a g e n t u p o n s t a r t u p o f s y s t e m . C r e d e n t i a l s p r o v i d e d t o en g i n e e r a n d c o m m i s s i o n i n g a g e n t s h a l l n o t e x p i r e d u r i n g t h e pe r i o d o f t h e w a r r a n t y . Le v e l 2 - O c c u p a n t l e v e l : M o n i t o r i n g a n d c o n t r o l o f s p a c e te m p e r a t u r e s e t p o i n t s , s i m p l e o v e r r i d e s , t r e n d i n g s e t u p , a l a r m i n g se t u p a n d a d j u s t m e n t . Le v e l 3 - T e c h n i c i a n l e v e l : F u l l c o n t r o l , o v e r r i d e , a d j u s t m e n t , a n d pr o g r a m m i n g c a p a b i l i t i e s . GR A P H I C S - A l l B A S p o i n t s s h a l l b e r e p r e s e n t e d b y g r a p h i c d i s p l a y o n th e w e b b a s e d i n t e r f a c e . N e w i t e m s s u c h a s p u m p s , b o i l e r s , c o n t r o l va l v e s , a n d d a m p e r m o t o r s s h a l l h a v e a n i m a t e d g r a p h i c s t h a t v a r y de p e n d i n g o n s t a t u s . WA R R A N T Y - C o n t r ' r s h a l l i n c l u d e a l l c o n t r o l p r o g r a m m i n g a d j u s t m e n t s fo r a p e r i o d o f 1 y e a r f o r a n y a n d a l l o p t i m i z a t i o n m e a s u r e s . VA R I A B L E F R E Q U E N C Y D R I V E S ( V F D s ) - P r o v i d e A d d A l t e r n a t e t o in c l u d e B A C n e t c o m p a t i b l e i n t e r f a c e f o r V F D s t o m o n i t o r s t a t u s a n d op e r a t i n g c o n d i t i o n s t h r o u g h i t ' s c o m m unication port. The following points sh a l l b e m o n i t o r e d a n d t r e n d e d t h r o u g h e a c h V F D s : 1.Motor speed (RPM)2.Motor frequency (Hz)3.Load Current (AMPS)4.Line Current (AMPS)5.Motor Runtime 6.VFD status 7.In hand, off, or auto 8.In Fault Condition 9.In Bypass 10.% Torque 11.Power (kW)12.Consumption (kWh) - Resettable AL A R M S - P r o v i d e t h e f o l l o w i n g s p e c i f i c d i a l - o u t a l a r m s t o d e s t i n a t i o n de t e r m i n e d b y t h e O w n e r : 1.Boiler low water limit.2.Generalized equipment failure alarm new equipment and existing equipment with updated sequences. AD J U S T A B I L I T Y - W i t h t h e e x c e p t i o n o f d e s i g n t e m p e r a t u r e s , a l l se t p o i n t s , t i m e d e l a y s , d u r a t i o n s , r e s e t s c h e d u l e s , a n d o t h e r c o n t r o l va r i a b l e s s h a l l b e a d j u s t a b l e . V a r i a b l e s r e q u i r e d f o r c o n t r o l s im p l e m e n t a t i o n t h a t a r e n o t d e f i n e d i n the sequences of control shall be de f i n e d b y c o n t r o l s c o n t r a c t o r i n t h e i r shop drawing submittal. Contractor's su g g e s t e d a d j u s t m e n t s t o v a r i a b l e s d e f i ned in the Sequences of Control, if an y , s h a l l b e s u b m i t t e d i n t h e c o n t r o l s d r a w i n g s . RE S E T C U R V E G R A P H I C S - C e r t a i n c o n t r o l s s e q u e n c e s i n t h i s d r a w i n g se t c o n t a i n r e s e t c u r v e s d e s c r i p t i o n s t h a t a r e p r o v i d e d g r a p h i c a l l y . Th o u g h t h e s e c u r v e s r e p r e s e n t p r o p o r t i onal control only in the simplest in t e r p r e t a t i o n , t h e c o n t r o l s s y s t e m i n tent is to utilize proportional-integral (P I ) a n d / o r p r o p o r t i o n a l - i n t e g r a l - d e r i v a t i v e ( P I D ) l o o p s t o p e r m i t t u n i n g o f co n t r o l s s y s t e m s r e s p o n s e , l i m i t o v e r s h o o t / u n d e r s h o o t , a n d i m p r o v e sy s t e m s t a b i l i t y . R e s e t c u r v e g r a p h i cs are provided as suggested starting po i n t s f o r t h e p r o p o r t i o n a l c o m p o n e n t o n l y; all endpoints, offsets, slopes, et c a r e f l e x i b l e . CO N T R O L S R E C O R D D R A W I N G S R E Q U I R E D - C o n t r a c t o r s h a l l ma i n t a i n , t h r o u g h t h e c o u r s e o f t h e p r o j e c t , a c o m p r e h e n s i v e r e c o r d o f me c h a n i c a l e q u i p m e n t a n d c o n t r o l s r e l a t e d a d d e n d a ( A S I ' s , R F I ' s , a n d CC D ' s ) , a d j u s t m e n t s t o s e t p o i n t s d e f ined herein, initial setpoints not de f i n e d h e r e i n . A n y s u g g e s t i o n s f o r a d j u s t m e n t s a n d / o r m o d i f i c a t i o n t o th e a p p r o v e d c o n t r o l s h o p d r a w i n g s t h a t a r i s e d u r i n g t h e c o u r s e o f co n s t r u c t i o n , s t a r t u p , a n d c o m m i s s i o n i n g s h a l l b e r e v i e w e d b y t h e en g i n e e r . A p p r o v e d c h a n g e s s h a l l b e r e c o r d e d o n t h e c o n t r o l s s h o p dr a w i n g s b e i n g u s e d a s c o n t r o l s r e c o r d d r a w i n g s . A l l s u c h c h a n g e s s h a l l be u p d a t e d e l e c t r o n i c a l l y a n d s u b m i t t e d t o t h e O w n e r d u r i n g p r o j e c t cl o s e o u t . TR E N D I N G - R e f e r t o s p e c i f i c a t i o n s e c t i o n 2 3 0 8 0 0 - C o m m i s s i o n i n g o f HV A C f o r B C S p o i n t t r e n d i n g r e q u i r e m e n t s , i n c l u d i n g t r e n d i n g f r e q u e n c y an d d a t a s t o r a g e . PO I N T S L I S T S - N o t a l l p o i n t s r e q ' d b y t h e s e c o n t r o l s d r a w i n g s a r e ne c e s s a r i l y p r o v i d e d w i t h p o i n t s l i s t s. Controls drawing submittal shall pr o v i d e c o m p l e t e p o i n t s l i s t s a n d n a m e/address of each point occurrence wi t h i n t h e p r o j e c t . SP A R E C A P A C I T Y - P r o v i d e s y s t e m a r chitecture/infrastructure with mi n i m u m s p a r e c a p a c i t y r e q u i r e d t o accommodate future integration of ex i s t i n g A u t o m a t r i x P U P n e t w o r k t o B A C n e t p r o t o c o l a n d c o n t r o l l e r s . SC A L E : 1 CO N T R O L S Y S T E M A R C H I T E C T U R E ( B A C N E T ) NO N E BA C N E T WE B SE R V E R SU P E R V I S O R Y N E T W O R K C O N T R O L L E R (T Y P . ) UN I T A R Y E Q U I P M E N T C O N T R O L L E R (T Y P . ) BA C N E T C O M M B U S ( T Y P . ) GE N E R I C I / O C O N T RO L L E R ( T Y P . ) TE R M I N A L D E V I C E CO N T R O L L E R ( T Y P . ) EX I S T I N G L O W V O L T A G E IN T E G R A T I O N S Y S T E M IN T E R N E T (B Y O T H E R S ) LA N (B Y O T H E R S ) PR O V I D E N E W W E B S E R V E R . CO N F I R M S U I T A B I L I T Y O F U T I L I Z I N G EX I S T I N G E Q U I P M E N T P R I O R T O B I D D I N G . OW N E R F U R N I S H E D D E S K T O P IN E X I S T I N G E N G I N E E R I N G OF F I C E . DE S C R I P T I O N  ‐   TH E  HE A T I N G  WA T E R  PL A N T  CO N S I S T S  OF TH R E E  CA S T  IR O N  BO I L E R S  WI T H  PR I M A R Y  CO N S T A N T VO L U M E  BO I L E R  CI R C U L A T I O N  PU M P S  AN D  FU L L Y MO D U L A T I N G  BU R N E R S ,  TW O  VF D  DR I V E N  BU I L D I N G HE A T I N G  WA T E R  PU M P S  SE R V I N G  VE N T I L A T I O N  CO I L S ,  TW O VF D  DR I V E N  HE A T I N G  WA T E R  PU M P S ,  FO U R  IN D I R E C T ‐FI R E D DO M E S T I C  HO T  WA T E R  HE A T E R S ,  FO U R  CO N S T A N T  VO L U M E DO M E S T I C  HO T  WA T E R  PU M P S ,  SN O W M E L T  HE A T EX C H A N G E R S  AN D  PU M P S ,  AN D  PO O L / S P A  HE A T EX C H A N G E R S  AN D  PU M P S . A HE A T  TI M E R  MU L T I ‐MO D  PL A T I N U M  CO N T R O L  PA N E L PA I R E D  WI T H  A HE A T  TI M E  SY S T E M  CO N T R O L  PA N E L  SH A L L AC T I V A T E  AN D  CO N T R O L  BO I L E R  ST A T I N G  AN D  AS S O C I A T E D BO I L E R  PU M P S .    BA S  SH A L L  CO N T R O L  TH E  BU I L D I N G CI R C U L A T I O N  PU M P S . SC H E D U L I N G  ‐   TH E  HE A T I N G  WA T E R  PL A N T  SH A L L  BE EN A B L E D  TO  PR O D U C E  HE A T I N G  WA T E R  AT  AL L  TI M E S . HE A T I N G  WA T E R  PR O D U C T I O N  ‐ HE A T I N G  WA T E R  SU P P L Y  (H W S )  SE T P O I N T  SH A L L  BE  RE S E T FR O M  18 0 ° F  TO  16 0 ° F  AS  OU T S I D E  AI R  TE M P E R A T U R E  RI S E S FR O M  ‐ 20 ° F  TO  70 ° .    HW S  TE M P E R A T U R E  SE T P O I N T  SH A L L BE  FI X E D  DU R I N G  DO M E S T I C  HO T  WA T E R  PR O D U C T I O N DE M A N D  AS  SP E C I F I E D  BE L O W .    HW S  SE T P O I N T  SH A L L  BE MA I N T A I N E D  BY  HE A T  TI M E R  PI D  LO O P  ST A G I N G  ON BO I L E R S  IN  SE Q U E N C E .        EN A B L E  EA C H  AD D I T I O N A L  BO I L E R ST A G E  UP O N  A DR O P  IN  HW S  TE M P E R A T U R E  OF  5° F  BE L O W HW S  TE M P E R A T U R E  SE T P O I N T  FO R  MO R E  TH A N  15 MI N U T E S  ‐ OR ‐  UP O N  A DR O P  OF  10 ° F  BE L O W  SE T P O I N T  AT AN Y  TI M E .    AL L  BO I L E R S  SH A L L  OP E R A T E  VI A  FA C T O R Y MO U N T E D  CO N T R O L S  TO  PR O V I D E  HW S  SE T P O I N T  AS DI C T A T E D  BY  TH E  BC S .    DI S A B L E  BO I L E R S  ST A G E S IN C R E M E N T A L L Y  UP O N  A RI S E  OF  HW S  TE M P E R A T U R E  TO 5° F  AB O V E  SE T P O I N T  FO R  MO R E  TH A N  15  MI N U T E S  ‐ OR ‐ UP O N  A RI S E  OF  10 ° F  AB O V E  SE T P O I N T  AT  AN Y  TI M E .    UP O N EN A B L I N G  BO I L E R ,  ST A R T  AS S O C I A T E D  BO I L E R  CI R C U L A T I O N PU M P  AN D  CO N F I R M  FL O W  PR I O R  TO  FI R I N G  BO I L E R . HE A T  TI M E R  CO N T R O L  PA N E L  SH A L L  SE N D  BO I L E R  AN D PU M P  ST A T U S  AS  WE L L  AS  BO I L E R  AL A R M  ST A T U S  BA C K  TO BA S  FO R  RE P O R T I N G . PU M P  CO N T R O L  ‐ 1. B U I L D I N G  HE A T I N G  WA T E R  PU M P S  RE M A I N OP E R A T I O N A L  WH E N E V E R  OU T S I D E  AI R  TE M P E R A T U R E IS  BE L O W  60 ° F ,  OR  SH O U L D  AN Y  AI R  HA N D L I N G  UN I T BE  IN  FR E E Z E  PR E V E N T I O N  MO D E .    BU I L D I N G DI F F E R E N T I A L  PR E S S U R E  SH A L L  BE  MA I N T A I N E D  AT SE T P O I N T  (1 0  PS I  IN I T I A L ,  TO  BE  CO N F I R M E D  WI T H BA L A N C I N G  CO N T R A C T O R )    BY  ST A G I N G  ON  TH E PU M P S  IN  SE Q U E N C E  AS  WE L L  AS  RA M P I N G  UP  AN D DO W N  TH E  PU M P S '  VF D S .    MA I N T A I N  LO O P  PR E S S U R E IN I T I A L L Y  WI T H  ON E  HE A T I N G  WA T E R  PU M P .    WH E N LE A D  PU M P  IS  AT  80 %  OU T P U T ,  EN E R G I Z E  LA G  PU M P AN D  CO N T R O L  BO T H  VF D ' S  IN  UN I S O N .    WH E N  BO T H VF D ' S  AR E A  AT  30 %  OR  LE S S ,  DE ‐EN E R G I Z E  LA G  PU M P . RO T A T E  LE A D  PU M P  DE S I G N A T I O N  ON  A WE E K L Y  BA S I S . BU I L D I N G  HO T  WA T E R  SU P P L Y  TE M P E R A T U R E  CO N T R O L  ‐ MO D U L A T E  BU I L D I N G  TH R E E  WA Y  TE M P E R A T U R E  CO N T R O L VA L V E  TO  MA I N T A I N  SU P P L Y  WA T E R  TE M P E R A T U R E  OF 16 0 ° F  AD J .  (T O  BE  CO N F I R M E D  BY  PR E ‐TE S T  AN D ME A S U R E M E N T  EX E R C I S E )  . DO M E S T I C  HO T  WA T E R  PR O D U C T I O N  ‐ TH E  DO M E S T I C  HO T  WA T E R  HE A T E R S  AR E  SU P P L I E D  WI T H AN  IN T E G R A L  TA N K  AQ U A S T A T  TH A T  WI L L  CO N T R O L AS S O C I A T E D  TA N K  CI R C U L A T I O N  PU M P .    BM S  SH A L L MO N I T O R  TA N K  TE M P E R A T U R E ,  PU M P  ST A T U S ,  AN D  HW S SE T P O I N T .    PU M P  SH A L L  ST A R T  UP O N  A DR O P  IN  TA N K TE M P E R A T U R E  TO  15 5 ° F  AD J .    PU M P  SH A L L  ST O P  UP O N  A RI S E  IN  TA N K  TE M P E R A T U R E  TO  18 0 ° F  AD J .  FO R  MO R E  TH A N 5 MI N U T E S .    SH O U L D  DO M E S T I C  HO T  WA T E R  SU P P L Y TE M P E R A T U R E  FA L L  BE L O W  14 0 ° F  AB A N D O N  BO I L E R  RE S E T TE M P E R A T U R E  SC H E D U L E  AN D  OV E R R I D E  HW S  SE T P O I N T  TO 18 0 ° F .    UP O N  A RI S E  IN  DO M E S T I C  HO T  WA T E R  TO  14 5 ° F  FO R 15  MI N U T E S  OR  15 0 ° F  ST O P  WA T E R  HE A T E R  PU M P S  AN D RE T U R N  HW S  TE M P E R A T U R E  TO  RE S E T  SC H E D U L E .    IF DO M E S T I C  HO T  WA T E R  TE M P E R A T U R E  IS  HI G H E R  TH A N 15 0 ° F  TH A N  DO M E S T I C  MI X I N G  VA L V E  MA Y  DE L I V E R  WA T E R IN  EX C E S S  OF  12 0 ° F .    UP O N  A RI S E  IN  DO M E S T I C  HO T  WA T E R SU P P L Y  TE M P E R A T U R E  TO  15 0 ° F  ST O P  AL L  WA T E R  HE A T E R PU M P S ,  SH U T  EM E R G E N C Y  IS O L A T I O N  VA L V E  AN D  AL A R M BM S . BO I L E R  RO O M  EM E R G E N C Y  PO W E R  OF F ‐ BO I L E R  MA N U F A C T U R E R  SH A L L  PR O V I D E  CO N T R O L  WI R I N G SC H E M A T I C  FO R  BO I L E R  SH U T D O W N  SW I T C H E S  LO C A T E D  AT BO I L E R  RO O M  EX I T  DO O R .    SH U T D O W N  CO N T R O L  SY S T E M S SH A L L  CO M P L Y  WI T H  TH E  LA T E S T  ED I T I O N  OF  AS M E  CS D ‐1 “C O N T R O L S  AN D  SA F E T Y  DE V I C E S  FO R  AU T O M A T I C A L L Y FI R E D  BO I L E R S .    DI V I S I O N  15  CO N T R A C T O R  SH A L L  PR O V I D E TH E  SW I T C H E S  AN D  AL L  RE Q U I R E D  CO N T R O L  WI R I N G . FE A T U R E S  ‐ 1. R O T A T I O N A L L Y  SE Q U E N C E  LE A D  BO I L E R  AN D  ON  A WE E K L Y  BA S I S . 2. R O T A T I O N A L L Y  SE Q U E N C E    PU M P S  AS  NO T E D  AB O V E . 3. H O U R L Y  TR E N D  TH E  FO L L O W I N G  ‐ a. H I G H  TE M P E R A T U R E  HE A T I N G  WA T E R  SU P P L Y  & RE T U R N  TE M P E R A T U R E S b. L O W  TE M P E R A T U R E  HE A T I N G  WA T E R  SU P P L Y  & RE T U R N  TE M P E R A T U R E S c. D O M E S T I C  HO T  WA T E R  TA N K  TE M P E R A T U R E S 4. G E N E R A T E  AN  AL A R M  SH O U L D  AN Y  PU M P  OR  BO I L E R ST A T U S  NO T  MA T C H  CO M M A N D SE Q U E N C E O F C O N T R O L (E ) P U P C O M M B U S ( T Y P . ) NE W L O W V O L T A G E IN T E G R A T I O N S Y S T E M AU T O M A T R I X N E X U S SI N G L E P O R T TE AI OSA TEMP LO C A T E S E N S O R O N N O R T H E R L Y WA L L O F F A C I L I T Y A N D P R O V I D E SH I E L D , T Y P . SC A L E : 2 G L O B A L C O N T R O L S C O M P O N E N T S NO N E CP AO BO BI SUPPLY TEMP SETPOINT BOILER ENABLE/DISABLE BOILER STATUS BO BI BOILER CIRC START/STOP BOILER CIRC STATUS BI BOILER ALARM SC A L E : 3 DI F F E R E N T I A L P R E S S U R E S E N S O R NO N E TY P I C A L S Y S E M DP T SY S T E M D I F F E R E N T I A L P R E S S U R E TR A N S D U C E R T Y P . 3 . AI SYSTEM DIFF. PRESSURE LO A D AOBOBIBI P-6 SPEED P-6 START/STOP P-6 STATUS P-6 ALARMAOBOBIBI P-7 SPEED P-7 START/STOP P-7 STATUS P-7 ALARM SC A L E : 4 BO I L E R C O N T R O L S S C H E M T I C NO N E AOBOBIBI P-5 SPEED P-5 START/STOP P-5 STATUS P-5 ALARMAOBOBIBI P-8 SPEED P-8 START/STOP P-8 STATUS P-8 ALARMBOBI P-14 ENABLE/DISABLE P-14 STATUSBOBI P-15 ENABLE/DISABLE P-15 STATUSBOBI P-16 ENABLE/DISABLE P-16 STATUSBOBI P-17 ENABLE/DISABLE P-17 STATUS CP AO BO BI SUPPLY TEMP SETPOINT BOILER ENABLE/DISABLE BOILER STATUS BO BI BOILER CIRC START/STOP BOILER CIRC STATUS BI BOILER ALARM CP AO BO BI SUPPLY TEMP SETPOINT BOILER ENABLE/DISABLE BOILER STATUS BO BI BOILER CIRC START/STOP BOILER CIRC STATUS BI BOILER ALARM BI TANK LOW TEMP CP BI TANK HIGH TEMP BI TANK LOW TEMPCPBI TANK HIGH TEMPBI TANK LOW TEMPCPBI TANK HIGH TEMPBI TANK LOW TEMPCPBI TANK HIGH TEMP1"1"1" 1-1 / 2 " (N ) E T - 1 (N ) E T - 2 3" HWR STATUS DIFF. FROM CMD TREND VALUE TREND STATUS ROTATIONALLY SEQUNCE NO T E S XX Bo i l e r E n a b l e / D i s a b l e ( B - 1 , B - 2 , B - 3 ) X X Bo i l e r A l a r m ( B - 1 , B - 2 , B - 3 ) X Bo i l e r H W S T e m p S e t p o i n t ( B - 1 , B - 2 , B - 3 ) X Pu m p S / S ( P - 5 , P - 6 , P - 7 , P - 8 ) X XX XX X SY S T E M P O I N T S L I S T - - H e a t i n g W a t e r S y s t e m AN A L O G BIN A R Y SY S T E M F E A T U R E IN P U T O U T P U T I N P U T O U T P U T A L A R M S P R O G R A M S SY S T E M P O I N T D E S C R I P T I O N GRAPHIC SCREEN ANIMATED POINT ON GRAPHIC TEMPERATURE PRESSURE RELATIVE HUMIDITY CO2 KWH BTU HR GPM PERCENT CFM DDC (4-20 ma, 0-10 vdc) STATUS STATUS ON/OFF FILTER STATUS STATUS OPEN/CLSD. TIMED OVERRIDE PULSE STOP/START OPEN/CLOSED LOCK OUT ENABLE/DISABLE HIGH/LOW SPEED FLOATING CONTROL HIGH OR LOW VALUE OUT OF RANGE FREEZESTAT LEAD/LAG Em e r g e n c y P o w e r O f f ( E P O ) XX X Bo i l e r S t a t u s ( B - 1 , B - 2 , B - 3 ) XX X X X Pu m p S t a t u s ( P - 5 , P - 6 , P - 7 , P - 8 ) X Pu m p V F D S p e e d ( P - 5 , P - 6 , P - 7 , P - 8 ) XX HW S T e m p e r a t u r e XX X X X HW R T e m p e r a t u r e XX X X X HW D i f f P r e s s ( P - 5 , P - 6 , P - 7 , P - 8 ) XX X X Bu i l d i n g 3 W a y C o n t r o l V a l v e XX X Wa t e r H e a t e r T a n k T e m p e r a t u r e ( H W H X - 1 T H R U 4 ) XX X Bu i l d i n g H W R e t u r n T e m p e r a t u r e XX X Re c i r c P u m p S / S ( P D H R - 1 , P D H R - 2 , P D H R - 3 ) XX X Re c i r c P u m p S t a t u s ( P D H R - 1 , P D H R - 2 , P D H R - 3 ) XX X X GE N E R A L N O T E S : DU P L I C A T E P O I N T S E X I S T . R E F E R T O F L O W D I A G R A M F O R Q U A N T I T I E S . AO BUILDING 3 WAY CONTROL VALVE TANK TEMPERATURE SETTINGS AND SEQUENCE INTEGRAL TO WATER HEATER CONTROLLER. TYP.RE: SEQUENCE OF CONTROL.SPA, POOL, AND SNOWMELT PUMPS AND HEAT EXCHANGERS CONTROLS AND SEQUENCES TO REMAIN. Bo i l e r C i r c P u m p S / S ( B P - 1 , B P - 2 , B P - 3 ) XX Bo i l e r C i r c P u m p S t a t u s ( B P - 1 , B P - 2 , B P - 3 ) XX X X X Bo i l e r H W S T e m p e r a t u r e ( B - 1 , B - 2 , B - 3 ) XX X BO EMERGENCY POWER OFF (EPO)EP O Pu m p V F D A l a r m ( P - 5 , P - 6 , P - 7 , P - 8 ) X Bu i l d i n g H W S u p p l y T e m p e r a t u r e XX X X X Wa t e r H e a t e r P u m p S / S ( P - 1 4 , P - 1 5 , P - 1 6 , P - 1 7 ) XX Wa t e r H e a t e r P u m p S t a t u s ( P - 1 4 , P - 1 5 , P - 1 6 , P - 1 7 ) XX X X IN T E G R A L T O W A T E R H E A T E R R E : S E Q U E N C E BOBI P-DHR-1 START/STOP P-DHR-1 STATUSBOBI P-DHR-2 START/STOP P-DHR-2 STATUSBOBI P-DHR-3START/STOP P-DHR-3 STATUS IN T E G R A L T O W A T E R H E A T E R R E : S E Q U E N C E TE TE TE AI HW S T E M P E R A T U R E AI HW R T E M P E R A T U R E AI BO I L E R H W S T E M P E R A T U R E TE AI BO I L E R H W S T E M P E R A T U R E AI BO I L E R H W S T E M P E R A T U R E TE AIHWS TEMPERATUREAIHWR TEMPERATURE TETETE Bu i l d i n g D H W S u p p l y T e m p e r a t u r e XX X X X LOCATE DOMESTIC HOT WATER DISCHARGE TEMPERATURE SENSOR AND EMERGENCY SHUT OFF IN MAIN HEADER PIPE OF 120F DHW. RE:M2.1 FOR LOCATION. CP CP BACNET PROTOCOL COMMUNICATIONS LINK TO BAS HEAT TIMER BOILER PLANT CONTROL PANELS. PO I N T S A S S O C I A T E D WI T H H E A T T I M E R CO N T R O L S Y S T E M PA N E L S . AO HWS SETPOINT BO HEATING WATER ENABLE PO I N T S AS S O C I A T E D W I T H BU I L D I N G AU T O M A T I O N SY S T E M . AIDHW SUPPLY TEMPERATURE BODHW EMERGENCY SHUT OFF FS FS FS DH W E m e r g e n c y S h u t O f f V a l v e X X M4.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M40.dwg Printed By: eng-ntt March 18, 2014 - 5:27pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW MECHANICALCONTROLS BO I L E R S C H E D U L E MA R K S E R V I C E BO I L E R TY P E FU E L TY P E HE A T I N G C A P A C I T Y L. W . T . (° F ) E. W . T . (° F ) BU R N E R VE N T TY P E MA N U F A C T U R E R * & M O D E L # AC C E S S O R I E S R E M A R K S IN P U T @ S . L . (M B H ) OU T P U T @ A L T . MI N I M U M A. F . U . E . HP R P M VO L T / PH B- 1 HE A T I N G WA T E R CA S T I R O N SE C T I O N A L NA T U R A L GA S 33 4 8 2 7 7 6 8 3 . 5 1 8 0 1 5 0 1- 1 / 2 34 5 0 20 8 / 3 C A T I I I P E E R L E S S T C I I - 1 1 - A, B , C . D B- 2 HE A T I N G WA T E R CA S T I R O N SE C T I O N A L NA T U R A L GA S 33 4 8 2 7 7 6 8 3 . 5 1 8 0 1 5 0 1- 1 / 2 34 5 0 20 8 / 3 C A T I I I P E E R L E S S T C I I - 1 1 - A, B , C , D B- 3 HE A T I N G WA T E R CA S T I R O N SE C T I O N A L NA T U R A L GA S 33 4 8 2 7 7 6 8 3 . 5 1 8 0 1 5 0 1- 1 / 2 34 5 0 20 8 / 3 C A T I I I P E E R L E S S T C I I - 1 1 - A, B , C , D MA N U F A C T U R E R S : * P E E R L E S S , L O C H I N V A R , P A T T E R S O N K E L L Y , V I E S S M A N N O R B U D E R U S GE N E R A L N O T E S : A: BO I L E R G A S T R I M T O I N C L U D E : P I L O T G A S C O C K , G A S P R E S S U R E R E G U L A T O R, S O L E N O I D G A S V A V L E , M A N U A L G A S C O C K , G A S P R E S S U R E R E G U L A T O R , M O T O R I Z E D S A F T E Y G A S V A L V E , M O T O R I Z E D O P E R A T I N G G A S VA L V E , L E A K T E S T V A L V E , B U T T E R F L Y M O D U L A T I N G G A S V A V L E , A N D T W O L E A K T E S T C O C K S . B: PR O V I D E B O I L E R C O N T R O L E R W I T H S E Q U E N C I N G C O N T R O L H O T W A T E R D E M A N D , P R O O F O F F L O W , S T A R T S I G N A L F O R P R I M A R Y P U M P S , C O N T R O L O V E R BO I L E R F I R I N G R A T E A N D S T A G I N G A N D B A C N E T O U T P U T . C: U N I T S T A N D A R D W I T H A U T O M A T I C L O C K I N G B A C K D R A F T D A M P E R . P R O V I D E W I T H 1 4 " B A R O M E T R I C D A M P E R . D: P R O V I D E W I T H F U L L Y M O D U L A T I N G B U R N E R S I Z E D T O M A I N T A I N B O I L E R O U T P U T A T E L E V A T I O N . PUMP SCHEDULE MA R K S E R V I C E T Y P E G P M TDH (FT)FLUIDMOTORMANUFACTURER*& MODEL #ACCESSORIESREMARKSHPRPMVOLT/PH (N ) B P - 1 PR I M A R Y B O I L E R CI R C VE R T I C A L I N L I N E 2 0 0 1 5 30%GLYCOL1.51150208/3BELL & GOSSETT SERIES 80 SC 5X5X7-- (N ) B P - 2 PR I M A R Y B O I L E R CI R C VE R T I C A L I N L I N E 2 0 0 1 5 30%GLYCOL1.51150208/3BELL & GOSSETT SERIES 80 SC 5X5X7-- (N ) B P - 3 PR I M A R Y B O I L E R CI R C VE R T I C A L I N L I N E 20 0 1 5 30%GLYCOL1.51150208/3BELL & GOSSETT SERIES 80 SC 5X5X7-- (N ) P - 5 SE C O N D A R Y BU I L D I N G H E A T I N G WA T E R VE R T I C A L I N L I N E 30 0 3 2 30%GLYCOL51750208/3BELL & GOSSETT SERIES 80 SC 5X5X7-A (N ) P - 6 SE C O N D A R Y BU I L D I N G H E A T I N G WA T E R VE R T I C A L I N L I N E 30 0 3 2 30%GLYCOL51750208/3BELL & GOSSETT SERIES 80 SC 5X5X7-A (E ) ( R ) P - 7 SE C O N D A R Y PE N T H O U S E M U A HE A T I N G W A T E R HO R I Z . CL O S E - C O U P L E D EN D S U C T I O N 14 0 6 2 30%GLYCOL51750208/3AURORA 3341-BF 2 X2.5X9.5-B (E ) ( R ) P - 8 SE C O N D A R Y PE N T H O U S E M U A HE A T I N G W A T E R HO R I Z . CL O S E - C O U P L E D EN D S U C T I O N 14 0 6 2 30%GLYCOL51750208/3AURORA 3341-BF 2 X2.5X9.5-B (E ) P - 9 SE C O N D A R Y SN O W M E L T HE A T I N G W A T E R INLINE - - - - - - - - - (E ) P - 1 0 SE C O N D A R Y S P A HE A T I N G W A T E R INLINE - - - - - - - - - (E ) P - 1 1 SE C O N D A R Y S P A HE A T I N G W A T E R INLINE - - - - - - - - - (E ) P - 1 2 SE C O N D A R Y P O O L HE A T I N G W A T E R INLINE - - - - - - - - - (E ) P - 1 3 SE C O N D A R Y SN O M M E L T HE A T I N G W A T E R INLINE - - - - - - - - - (N ) P - 1 4 SE C O N D A R Y H W H X CI R C VE R T I C A L I N L I N E 82 1430%GLYCOL3/41750208/3BELL & GOSSETT SERIES 60 2X2X5-1/4-- (N ) P - 1 5 SE C O N D A R Y H W H X CI R C VE R T I C A L I N L I N E 82 1430%GLYCOL3/41750208/3BELL & GOSSETT SERIES 60 2X2X5-1/4-- (N ) P - 1 6 SE C O N D A R Y H W H X CI R C VE R T I C A L I N L I N E 82 1430%GLYCOL3/41750208/3BELL & GOSSETT SERIES 60 2X2X5-1/4-- (N ) P - 1 7 SE C O N D A R Y H W H X CI R C VE R T I C A L I N L I N E 82 1430%GLYCOL3/41750208/3BELL & GOSSETT SERIES 60 2X2X5-1/4-- (N ) P D H R - 1 DO M E S T I C H O T RE C I R C IN L I N E 20 12WATER0.17-120/1BELL & GOSSETT PL-45-LEAD-FREE BRONZE CONSTRUCTION (N ) P D H R - 2 DO M E S T I C H O T RE C I R C IN L I N E 20 12WATER0.17-120/1BELL & GOSSETT PL-45-LEAD-FREE BRONZE CONSTRUCTION (N ) P D H R - 3 KI T C H E N DO M E S T I C H O T RE C I R C IN L I N E 3 12WATER0.08-120/1BELL & GOSSETT PL-30-LEAD-FREE BRONZE CONSTRUCTION MA N U F A C T U R E R S : * B & G , G R U N D F O S , T A C O O R A U R O R A E Q U I V A L E N T GE N E R A L N O T E S : A: I N V E R T E R D U T Y M O T O R F O R V F D A P P L I C A T I O N . B: E X I S T I N G M O T O R T O B E F I T T E D W I T H N E W V F D . DO M E S T I C W A T E R H E A T E X C H A N G E R S C H E D U L E MA R K S E R V I C E T Y P E S I D E G P M FL U I D E. W . T . (° F ) L. W . T .(°F)MAX PRESSURE DROP (PSI)FOULING FACTORHEATTRANSFER(MBH)MANUFACTURER* &MODEL #ACCESSORIESREMARKS WH - 1 DO M E S T I C HO T W A T E R IN S T A N T A N E O U S IN D I R E C T HO T 8 2 30 % GL Y C O L 18 0 1 6 0 5.0005800THERMO 2000 TURBOMAX 109-- CO L D 4 4 W A T E R 55 1 4 0 7 . 0 WH - 2 DO M E S T I C HO T W A T E R IN S T A N T A N E O U S IN D I R E C T HO T 8 2 30 % GL Y C O L 18 0 1 6 0 5 .0005800THERMO 2000 TURBOMAX 109-- CO L D 4 4 W A T E R 55 1 4 0 7 . 0 WH - 3 DO M E S T I C HO T W A T E R IN S T A N T A N E O U S IN D I R E C T HO T 82 30 % GL Y C O L 18 0 1 6 0 5 .0005800THERMO 2000 TURBOMAX 109-- CO L D 4 4 W A T E R 55 1 4 0 7 . 0 WH - 4 DO M E S T I C HO T W A T E R IN S T A N T A N E O U S IN D I R E C T HO T 82 30 % GL Y C O L 18 0 1 6 0 5 .0005800THERMO 2000 TURBOMAX 109-- CO L D 4 4 W A T E R 55 1 4 0 7 . 0 MA N U F A C T U R E R S : * T H E R M O 2 0 0 0 , B & G , P A T T E R S O N - K E L L Y , T A C O , T R A N T E R GE N E R A L N O T E S : A: UN I T E Q U I P P E D W I T H A Q U A S T A T T O I N T E R F A C E WI T H C O R R E S P O N D I N G H E A T I N G W A T E R P U M P T O M A INTAIN TANK TEMPERATURE AT SETPOINT MINUS AN ADJUSTABLE DIFFERENTIAL SET TO 20°F. AQUASTAT BREAKS CONTACT WI T H C O R R E S P O N D I N G P U M P W H E N T A N K T E M P E R A T U R E R I S E S O V E R M A X I M U M T E M P E R A T U R E S E T - P O I N T S E T A T 1 8 5 ° F . B: TA N K E Q U I P P E D W I T H F A C T O R Y I N S T A L L E D R E L I E F V A L V E S E T T O 5 0 P S I A N D T H E R M A L L Y I N S U L A T I N G F I B E R G L A S S J A C K E T . T A N K T O B E M O U N T E D ON 4" HOUSEKEEPING PAD. MI S C . H E A T E X C H A N G E R S C H E D U L E MA R K S E R V I C E T Y P E S I D E G P M FL U I D E. W . T . (° F ) L. W . T . (° F ) MAX PRESSURE DROP (PSI)FOULING FACTORHEATTRANSFER(MBH)MANUFACTURER* &MODEL #ACCESSORIESREMARKS HX - 3 SP A WA L L MO U N T E D HO T - - 18 0 1 6 0 ------ COLD - - - - - HX - 4 S N O W M E L T - HO T - - 18 0 1 6 0 ------ COLD - - - - - HX - 5 SP A - HO T - - 18 0 1 6 0 ----- COLD - - - - - HX - 6 PO O L - HO T - - 18 0 1 6 0 ----- COLD - - - - - HX - 8 S P A - HO T - - 1 8 0 1 6 0 - ----- COLD - - - - - MA N U F A C T U R E R S : * B & G , P A T T E R S O N - K E L L Y , T A C O , T R A N T E R GE N E R A L N O T E S : A: MI S C E L L A N E O U S M E C H A N I C A L E Q U I P M E N T S C H E D U L E MA R K S E R V I C E T Y P E C A P A C I T Y EL E C T R I C A L MA N U F A C T U R E R * & M O D E L # AC C E S S O R I E S R E M A R K S VO L T / PH GF - 1 GL Y C O L FE E D E R -5 0 G A L - 12 0 / 1 AX I O M I N D U S T R I E S PL U G A N D C O R D , L O W LE V E L A L A R M P A C K A G E - ET - 1 EX P A N S I O N TA N K BL A D D E R 1 5 8 G A L - - XY L E M B - 6 0 0 -- ET - 2 EX P A N S I O N TA N K BL A D D E R 1 5 8 G A L - - XY L E M B - 6 0 0 -- MA N U F A C T U R E R S : * R E M A R K S : A:B:C: M5.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M50.dwg Printed By: eng-ntt March 18, 2014 - 5:27pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW MECHANICALSCHEDULES SC A L E : EN L A R G E D M E C H A N I C A L R O O M S E C T I O N V I E W 1/ 2 " = 1 ' - 0 " 1.DO NOT SCALE DRAWINGS. VERIFY DIMENSION IN FIELD PRIOR TO COMMENCEMENT OF WORK.REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS.2.SUBCONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY G.C./ENGINEER OF DISCREPANCIES PRIOR TO STARTING ANY WORK.3.TAG AND RETURN TO THE OWNER ALL EXISTING FIXTURES AND EQUIPMENT TO BE REMOVED IN GOOD CONDITION.4.REPORT ANY EXISTING DAMAGED FIXTURES,EQUIPMENT AND/OR DEVICES TO THE OWNER IN WRITING PRIOR TO STARTING ANY WORK.5.DO NOT DISCONNECT OR PUT OUT OF SERVICE ANY SYSTEM WITHOUT COORDINATION WITH THE G.C./OWNER.6.PATCH AND REPAIR ALL INSULATION ON PIPING AND DUCTWORK DAMAGED DURING REMOVAL AND INSTALLATION OF EQUIPMENT.7.ALL VALVES SHALL BE INSTALLED ABOVE DROP-IN CEILING IN ACCESSIBLE LOCATIONS OR WITH ACCESS PANELS IN HARD-LID CEILINGS.NOTES: BO T T O M O F S T R U C T U R E BE A M S R U N P E R P E N D I C U L A R T O S H E E T BO T T O M O F D E C K RO U T E D O M E S T I C W A T E R P I P I N G T I G H T T O S T R U C T U R E . AV O I D D O M E S T I C W A T E R P I P I N G CO N F L I C T S W I T H B O I L E R F L U E S B Y PI P I N G A R O U N D O B S T R U C T I O N S . FL U E B R E A C H I N G T O E X I S T I N G LO C A T I O N (E ) P O O L A N D S N O W M E L T HE A T E X C H A N G E R S LI F T R O O M M6.03544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420M60.dwg Printed By: eng-ntt March 18, 2014 - 5:27pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 PROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ZRWSMW ENLARGED MECHANICAL ROOM SECTION VIEW '*' ISSUED FOR INFORMATION ONLY' ' NOT PART OF SET' ' ISSUED AS PART OF A SETISSUE LOG KEY:#DATEISSUE LOG ELECTRICAL SHEET INDEX TITLE ELECTRICAL COVER SHEETE0.1 11/01/2013BOILER ROOM ELECTRICAL DEMOLITION PLANED1.0 BOILER ROOM ELECTRICAL PLANE1.0 1.THESE DRAWINGS ACCOMPANY THE PUBLISHED CONSTRUCTION DOCUMENT SPECIFICATION BOOK (PROJECT MANUAL).2.DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK.3.VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS.4.SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK.5.SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS,CABLES, OUTLETS, ETC. AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT TO OWNER APPROVAL.6.REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID.7.WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT.8.WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES.9.PROVIDE PERMITS AND INSPECTIONS REQUIRED.10.PROVIDE WITH SHOP DRAWING SUBMITTAL, 1/4” SCALE LAYOUT DRAWINGS OF ROOMS WITH ELECTRICAL SWITCHBOARDS AND TRANSFORMERS. LAYOUTS SHALL SHOW LOCATIONS OF, AND SHALL BE COORDINATED WITH MECHANICAL EQUIPMENT. ALL EQUIPMENT SHALL BE DRAWN TO SCALE.11.CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.12.VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TO TRENCHING.PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS (CONDUIT AND/OR WIRE), PULLBOXES,TRANSFORMER PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED. BACKFILL TRENCHES TO 90 PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE ELECTRICAL UTILITY COMPANY WITH-IN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL, CONSTRUCTION SCHEDULING AND INSTALLATION OF THE UTILITY TRANSFORMER WITH THE UTILITY COMPANY. NOTIFY OWNER OF ANY SCHEDULING CONFLICTS.13.EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCE ONLY”. THE ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER WORK AS REQUIRED 14.PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED.15.PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES, RECEPTACLES, SWITCHES,LIGHTS, FIRE ALARMS DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED.16.ALL (E) EQUIPMENT, LAMPS, BALLASTS, ETC. BEING REMOVED SHALL BE DISCARDED IN ACCORDANCE WITH APPLICABLE EPA REQUIREMENTS.17.EXISTING LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE ITEMS BEING RELOCATED.18.VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN.19.INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION.20.FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED.21.CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.22.ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.23.WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT.24.ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS. EMT FITTINGS SHALL BE MALLEABLE IRON OR STEEL. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM CONDUIT SIZE IS 3/4”. FOLLOW NEC FOR MAXIMUM NUMBER OF CONDUCTORS PER CONDUIT. CONDUIT SHALL BE OF SUFFICIENT SIZE AND CONDUCTOR QUANTITY SHALL BE LIMITED TO ELIMINATE THE NEED TO DE-RATE CONDUCTORS. METAL CLAD CABLE IS [NOT] PERMITTED.25.ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT.26.WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS.27.PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT.28.PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS.29.FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT.30.FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER).31.SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER.32.GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER.33.SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC.SHALL BE CONNECTED AND OPERABLE.GENERAL NOTES:ELECTRICAL ONE-LINE DIAGRAM AND SCHEDULEE2.0 GF C I D U P L E X R E C E P T A C L E DU P L E X R E C E P T A C L E ; H A L F S W I T C H E D IS O L A T E D G R O U N D D U P L E X R E C E P T A C L E WA L L M O U N T E D S P E C I A L O U T L E T A S N O T E D SP E C I A L O U T L E T A S N O T E D JU N C T I O N B O X WA L L M O U N T E D J U N C T I O N B O X FL O O R M O U N T E D JU N C T I O N B O X DU P L E X R E C E P T A C L E M O U N T E D A B O V E C O U N T E R C FL U S H F L O O R M O U N T E D DU P L E X R E C E P T A C L E FL U S H F L O O R M O U N T E D D O U B LE D U P L E X R E C E P T A C L E FL U S H F L O O R M O U N T E D D U P L E X R E C E P T A C L E ; H A L F S W I T C H E D FL U S H F L O O R M O U N T E D D U P L E X R E C E P T A C L E A N D T E L E C O M DI V I S I O N 1 5 E Q U I P M E N T P O W E R C O N N E C T I O N FU S E D D I S C O N N E C T NO N F U S E D D I S C O N N E C T MO T O R S T A R T E R EN C L O S E D C I R C U I T B R E A K E R PU L L B O X PU S H B U T T O N TR A N S F O R M E R PA N E L B O A R D O R L O A D C E N T E R CO N T A C T O R EL E C T R I C M O T O R ME T E R TH E R M O S T A T AT S AU T O M A T I C T R A N S F E R S W I T C H ON E - L I N E D I A G R A M S Y M B O L S CI R C U I T H O M E R U N CO N D U I T R U N CO N D U I T R U N B E L O W G R A D E CO N D U I T U P CO N D U I T D O W N DI S C O N N E C T S W I T C H FU S E CI R C U I T B R E A K E R CU R R E N T T R A N S F O R M E R PO T E N T I A L T R A N S F O R M E R ME T E R SU R G E S U P P R E S S I O N D E V I C E VO L T - M E T E R SE L E C T O R S W I T C H GR O U N D GF GR O U N D F A U L T P R O T E C T I O N AM P - M E T E R ST SH U N T T R I P NO R M A L L Y O P E N C O N T A C T NO R M A L L Y C L O S E D C O N T A C T CO L D W A T E R G R O U N D C O N N E C T I O N BU I L D I N G S T E E L G R O U N D C O N N E C T I O N TI M E R S W I T C H MU L T I - O U T L E T P L U G S T R I P TI M E C L O C K PH O T O - C E L L SW I T C H TH E R M A L O V E R L O A D S W I T C H VA R I A B L E S P E E D S W I T C H KE Y S W I T C H LI G H T I N G F I X T U R E S Y M B O L S RE C E S S E D L I G H T I N G F I X T U R E WA L L M O U N T E D L I G H T WA L L M O U N T E D U P - L I G H T PE N D A N T M O U N T E D L I G H T SU R F A C E M O U N T E D L I G H T DI R E C T I O N A L / A D J U S T A B L E R E C E S S E D L I G H T I N G F I X T U R E MO N O - P O I N T L I G H T I N G F I X T U R E RE C E S S E D S T E P L I G H T FL U O R E S C E N T S T R I P L I G H T WA L L M O U N T E D L I N E A R F L U O R E S C E N T L I G H T RE C E S S E D O R S U R F A C E M O U N TE D F L U O R E S C E N T T R O F F E R FI X T U R E W I T H E M E R G E N C Y B A C K U P O R O N E M C I R C U I T WA L L M O U N T E D E X I T S I G N W / F A C E S & A R R O W S A S S H O W N EM E R G E N C Y L I G H T S CE I L I N G M O U N T E D E X I T S I G N W / F A C E S & A R R O W S A S S H O W N SW I T C H TH R E E - W A Y S W I T C H FO U R - W A Y S W I T C H DO O R J A M B S W I T C H LI G H T I N G C O N T R O L S Y M B O L S AW G - A M E R I C A N W I R E G A U G E AP - A C C E S S P O I N T AH J - A U T H O R I T Y H A V I N G J U R I S D I C T I O N BM S - B U I L D I N G M A N A G E M E N T S Y S T E M CA T V - C O M M U N I T Y ( C A B L E ) A N T E N N A T E L E V I S I O N S Y S T E M CC T V - C L O S E D C I R C U I T T E L E V I S I O N CP U - C E N T R A L P R O C E S S I N G U N I T FA - F I R E A L A R M FA C P - F I R E A L A R M C O N T R O L P A N E L GR D - G R O U N D GC - G E N E R A L C O N T R A C T O R ID F - I N T E R M E D I A T E D I S T R I B U T I O N F R A M E IG - I S O L A T E D G R O U N D IR - I N F R A R E D OC - O N C E N T E R MD F - M A I N D I S T R I B U T I O N F R A M E LA N - L O C A L A R E A N E T W O R K PA - P U B L I C A D D R E S S WA N - W I D E A R E A N E T W O R K WL A N - W I R E L E S S L O C A L A R E A N E T W O R K W - W A T T V - V O L T TT B - T E L E V I S I O N T E R M I N A L B O A R D EX T E R I O R P O L E M O U N T E D L I G H T EX T E R I O R P O S T ( B O L L A R D ) M O U N T E D L I G H T DA Y L I G H T P H O T O S E N S O R KE Y S W I T C H VA R I A B L E S P E E D S W I T C H DI M M E R TH R E E - W A Y D I M M E R LO W V O L T A G E S W I T C H WA L L O C C U P A N C Y S E N S O R / S W I T C H TH E R M A L O V E R L O A D S W I T C H SM A L L R O O M O C C U P A N C Y S E N S O R LA R G E R O O M O C C U P A N C Y S E N S O R CO R R I D O R O C C U P A N C Y S E N S O R S S3 OCOCSTSO SVSK OCSJS4 SKSVSTSPCTCTS AV SSMTCTPBCBN--JJJ AB B R E V I A T I O N S AF C - A B O V E F I N I S H E D C E I L I N G AF F - A B O V E F I N I S H E D F L O O R AF G - A B O V E F I N I S H E D G R A D E AL - A L U M I N U M BF G - B E L O W F I N I S H G R A D E C - C O N D U I T CK T - C I R C U I T CT - C U R R E N T T R A N S F O R M E R EM - E M E R G E N C Y EW C - E L E C T R I C W A T E R C O O L E R (E ) - E X I S T I N G FB O - F U R N I S H E D B Y O T H E R S GF I - G R O U N D F A U L T CI R C U I T I N T E R R U P T E R IC - I N T E R M E D I A T E C R O S S - C O N N E C T IA W - I N A C C O R D A N C E W I T H NI C - N O T I N C O N T R A C T DW - D I S H W A S H E R DI S P - G A R B A G E D I S P O S A L NL - N I G H T L I G H T NT S - N O T T O S C A L E RE F - R E F R I G E R A T O R TV S S - T R A N S I E N T V O L T A G E S U R G E S U P P R E S S O R UG - U N D E R G R O U N D UN O - U N L E S S N O T E D O T H E R W I S E WP - W E A T H E R P R O O F XP - E X P L O S I O N P R O O F +1 8 " - M O U N T I N G H E I G H T T O C E N T E R L I N E O F D E V I C E A B O V E F I N I S H F L O O R PO W E R S Y M B O L S SI N G L E R E C E P T A C L E DU P L E X R E C E P T A C L E DO U B L E D U P L E X R E C E P T A C L E 50% CONSTRUCTION DOC.100% CD / PERMIT 03/18/2014 E0.13544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 C:\Users\eng-ntt\local settings\temp\AcPublish_9024\354420E01.dwg Printed By: eng-ntt March 18, 2014 - 5:21pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 NTTMBSPROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 ELECTRICALCOVER SHEET LIFT LIFT ROO M LIFT ROOM PD H R 3 PD H R 1 B1 B2 P 14 P 15 P 3 P4 P5 P6 P 1 P 2 P7 P 8 1.EXISTING INFORMATION SHOWN IS FROM FIELD OBSERVATION AND MAY HAVE INACCURACIES. ALL EXISTING INFORMATION SHOWN IS FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK.2.THE DRAWINGS ARE DIAGRAMMATIC AND MAY NOT SHOW ALL DEMOLITION THAT IS REQUIRED. THE ELECTRICAL CONTRACTOR MUST VISIT THE SITE TO DOCUMENT ALL SITE CONDITIONS AND DETERMINE THE EXTENT OF DEMOLITION THAT WILL BE REQUIRED TO CONSTRUCT THE PROJECT AS IT IS DOCUMENTED.3.DISCONNECT EXISTING EQUIPMENT WHICH IS TO BE REMOVED AND RELOCATED. COORDINATE WITH OWNER TEMPORARY STORAGE OF SUCH ITEMS.PROTECT EXISTING EQUIPMENT WHICH IS TO REMAIN IN PLACE.4.REMOVE COMPLETELY ALL CONDUIT, BOXES AND WIRE ASSOCIATED WITH EQUIPMENT TO BE REMOVED. NO ELECTRICAL RACEWAY SHALL BE ABANDONED IN PLACE.5.REFER TO ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.NOTES:DISCONNECT MECHANICAL EQUIPMENT FOR RELOCATION. DEMO EXISTING WIRING AND DISCONNECTS WHERE NO LONGER IN USE. SEE SHEET E1.0 FOR NEW EQUIPMENT LOCATION.REMOVE RECEPTACLE FOR GLYCOL FEED PUMP.RELOCATE TO NEW LOCATION AS INDICATED ON E1.0.1FLAG NOTES: 1 1 2 2 PD H R 2 PD H R 4 SC A L E : BO I L E R R O O M E L E C T R I C A L D E M O L I T I O N P L A N 1/ 2 " = 1 ' - 0 " EF 1 (E ) P P A S E C . 1 (E ) P P A S E C . 2 (E ) W I R E W A Y AC1 ED1.0BOILER ROOM ELECTRICAL DEMO PLAN3544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420ED10.dwg Printed By: eng-ntt March 18, 2014 - 2:01pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 NTTMBSPROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 1.COORDINATE ELECTRICAL REQUIREMENTS AND LOCATIONS FOR NEW AND RELOCATED MECHANICAL EQUIPMENT WITH THE MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.2.SEE MECHANICAL EQUIPMENT SCHEDULE AND PANEL SCHEDULES ON SHEET E2.0 FOR ADDITIONAL INFORMATION.NOTES:RELOCATE EXISTING RECEPTACLE TO PROVIDE POWER FOR NEW GLYCOL FEED PUMP. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT TO NEW RECEPTACLE LOCATION.INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT TO RELOCATED EQUIPMENT LOCATION. PROVIDE NEW DISCONNECT.1FLAG NOTES: PD H R 1 PD H R 2 B2 B3 BP2 BP3 B1 BP1 P14 P15 P 7 P 8 P 5 P 6 2 2 (E ) P P A S E C . 1 (E ) P P A S E C . 2 (E ) W I R E W A Y SC A L E : BO I L E R R O O M E L E C T R I C A L P L A N 1/ 2 " = 1 ' - 0 " P16 P17 PD H R 3 1 GF P1 AC 1 E1.0BOILER ROOM ELECTRICAL PLAN3544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420E10.dwg Printed By: eng-ntt March 18, 2014 - 2:01pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 NTTMBSPROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014 SC A L E : EX I S T I N G P A R T I A L E L E C T R I C AL O N E - L I N E D I A G R A M NO N E 1.EXISTING INFORMATION SHOWN IS FROM FIELD OBSERVATION AND MAY HAVE INACCURACIES.ALL EXISTING INFORMATION SHOWN IS FOR REFERENCE ONLY. VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK.2.PANEL SCHEDULES MARKED (E) INDICATE EXISTING BRANCH CIRCUITING AT THE BEGINNING OF THE PROJECT.3.PANEL SCHEDULES MARKED (N) INDICATE BRANCH CIRCUITING AT THE CONCLUSION OF THE PROJECT.4.PROVIDE NEW BREAKERS IN EXISTING PANEL AS INDICATED ON PANEL SCHEDULES.NOTES: PA N E L 'P P A ' SE C . 2 TO ' M D P ' (L O C A T E D I N T H E A D J A C E N T EL E C T R I C A L R O O M ) PA N E L : (E ) P P A S E C T 1 VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:225 LO C A T I O N : BO I L E R R O O M MAIN:MLO MO U N T I N G : SU R F A C E MINIMUM AIC:10,000 NO . LO A D TY P E L O A D D E S C R I P T I O N BREAKERBUSBREAKERTYPELOAD DESCRIPTIONLOADNO. AB CPOLETRIPABCTRIPPOLEABC 1M (E ) E A S T A C U N I T 360+153M(E) (R) P-72 3M +M4 5 M +M6 7M (D ) P U M P # 6 315+153M(E) (R) P-88 9 M +M10 11 M +M12 13 (E ) N O L A B E L 315+153M(D) 5HP HW CIRC PUMP14 15 +M16 17 +M18 19 M (E ) E X F A N - 1 315+203M(E) WEST AHU-220 21 M +M22 23 M +M24 25 (E ) S U B P A N E L 380+153E(E) UNIT HEATER26 27 +E28 29 +E30 31 M (E ) E X F A N - 2 320+153E(E) UNIT HEATER32 33 M +E34 35 M +E36 37 E (E ) U N I T H E A T E R 315+303(E) NO LABEL38 39 E +40 41 E +42 LO A D T Y P E P A N E L T O T A L FE E D T H R U TO T A L SU B F E E D TO T A L FEEDER SUBTOTALDEMANDFEEDER TOTALGENERAL NOTES:A. (L ) L I G H T I N G 0 0125%0B. (R ) R E C E P T A C L E S 0 0NEC 2200C. (L M ) L A R G E S T M O T O R 0 025%0D. (M ) M O T O R S ( A L L ) 0 0100%0E. (E ) E Q U I P M E N T 0 0100%0SPECIFIC NOTES: (A ) A P P L I A N C E S 0 000(1)PANEL TOTAL (KVA):0.0(2)(3)PANEL TOTAL (A):0(4)(5) PA N E L : (E ) P P A S E C T 2 VOLTAGE:120/208V, 3PH, 4W MINIMUM BUS:225 LO C A T I O N : BO I L D E R R O O M MAIN:MLO MO U N T I N G : SU R F A C E MINIMUM AIC:10,000 NO . LO A D TY P E L O A D D E S C R I P T I O N BREAKERBUSBREAKERTYPELOAD DESCRIPTIONLOADNO. AB CPOLETRIPABCTRIPPOLEABC 1E (D ) N O R T H B O I L E R 340+153E(E) NORTHEAST UNIT HEATER2 3 E +E4 5 E +E6 7E (D ) S O U T H B O I L E R 340+153E(E) SOUTHEAST UNIT HEATER8 9 E +E10 11 E +E12 13 M (E ) E A S T A I R H A N D L E R 320+153M(E) HOUSEKEEPING AIR HANDLER14 15 M +M16 17 M +M18 19 M (E ) R A D I A T I O N BA S E B O A R D P U M P 330+403M(D) HOT WATER GEN APT PUMP20 21 M +M22 23 M +M24 25 M (E ) A I R C O M P R E S S O R 330+403M(D) NORTH HEATING PRIMARY PUMP26 27 M +M28 29 M +M30 31 SP A C E +201(E) NO LABEL32 33 S P A C E +SPACE34 35 SP A C E +SPACE36 37 SP A C E +SPACE38 39 S P A C E +SPACE40 41 S P A C E +SPACE42 LO A D T Y P E P A N E L T O T A L FE E D T H R U TO T A L SU B F E E D TO T A L FEEDER SUBTOTALDEMANDFEEDER TOTALGENERAL NOTES:A. (L ) L I G H T I N G 0 0125%0B. (R ) R E C E P T A C L E S 0 0NEC 2200C. (L M ) L A R G E S T M O T O R 0 025%0D. (M ) M O T O R S ( A L L ) 0 0100%0E. (E ) E Q U I P M E N T 0 0100%0SPECIFIC NOTES: (A ) A P P L I A N C E S 0 000(1)PANEL TOTAL (KVA):0.0(2)(3)PANEL TOTAL (A):0(4)(5) PA N E L : (N ) P P A S E C T 1 VO L T A G E : 12 0 / 2 0 8 V , 3 P H , 4 W MI N I M U M B U S : 22 5 LO C A T I O N : BO I L E R R O O M MA I N : ML O MO U N T I N G : SU R F A C E MI N I M U M A I C : 10 , 0 0 0 NO . LO A D TY P E L O A D D E S C R I P T I O N BR E A K E R BU S BR E A K E R TY P E L O A D D E S C R I P T I O N LO A D NO . AB CP O L E TR I P A B C TR I P PO L E AB C 1M (E ) E A S T A C U N I T 36 0 + 15 3 M (E ) ( R ) P - 7 2 3M + M4 5 M + M 6 7 M (N ) P - 5 34 0 + 15 3 M (E ) ( R ) P - 8 8 9 M + M 10 11 M + M1 2 13 (E ) N O L A B E L 31 5 + 40 3 M (N ) P - 6 14 15 + M 16 17 + M 18 19 M (E ) E X F A N - 1 31 5 + 20 3 M (E ) W E S T A H U - 2 20 21 M + M2 2 23 M + M2 4 25 (E ) S U B P A N E L 38 0 + 15 3 E (E ) U N I T H E A T E R 26 27 + E 28 29 + E3 0 31 M (E ) E X F A N - 2 32 0 + 15 3 E (E ) U N I T H E A T E R 32 33 M + E3 4 35 M + E3 6 37 E (E ) U N I T H E A T E R 31 5 + 30 3 (E ) N O L A B E L 38 39 E + 40 41 E + 42 LO A D T Y P E P A N E L T O T A L FE E D T H R U TO T A L SU B F E E D TO T A L FE E D E R SU B T O T A L DE M A N D F E E D E R T O T A L GE N E R A L N O T E S : A. (L ) L I G H T I N G 0 0 12 5 % 0 B. (R ) R E C E P T A C L E S 0 0 NE C 2 2 0 0 C . (L M ) L A R G E S T M O T O R 0 0 25 % 0 D. (M ) M O T O R S ( A L L ) 0 0 10 0 % 0 E. (E ) E Q U I P M E N T 0 0 10 0 % 0 SP E C I F I C N O T E S : (A ) A P P L I A N C E S 0 0 00 (1 ) PA N E L T O T A L ( K V A ) : 0. 0 (2 ) (3 ) PA N E L T O T A L ( A ) : 0 (4 ) (5 ) PA N E L : (N ) P P A S E C T 2 VO L T A G E : 12 0 / 2 0 8 V , 3 P H , 4 W MI N I M U M B U S : 22 5 LO C A T I O N : BO I L D E R R O O M MA I N : ML O MO U N T I N G : SU R F A C E MI N I M U M A I C : 10 , 0 0 0 NO . LO A D TY P E L O A D D E S C R I P T I O N BR E A K E R BU S BR E A K E R TY P E L O A D D E S C R I P T I O N LO A D NO . AB CP O L E TR I P A B C TR I P PO L E AB C 1 M (N ) B P - 1 32 0 + 15 3 E (E ) N O R T H E A S T U N I T HE A T E R 2 3 M + E4 5 M + E 6 7 M (N ) B P - 2 32 0 + 15 3 E (E ) S O U T H E A S T U N I T HE A T E R 8 9 M + E 10 11 M + E1 2 13 M (E ) E A S T A I R H A N D L E R 32 0 + 15 3 M (E ) H O U S E K E E P I N G A I R HA N D L E R 14 15 M + M 16 17 M + M1 8 19 M (E ) R A D I A T I O N BA S E B O A R D P U M P 33 0 + 20 3 E (N ) B - 1 20 21 M + E 22 23 M + E 24 25 M (E ) A I R C O M P R E S S O R 33 0 + 20 3 E (N ) B - 2 26 27 M + E 28 29 M + E 30 31 M (N ) B P - 3 32 0 + 20 1 (E ) N O L A B E L 32 33 M + 20 1 M (N ) P D H R - 1 , 2 , 3 34 35 M + 20 1M (N ) G F - 1 36 37 M (N ) P - 1 4 , 1 5 , 1 6 , 1 7 32 0 + 20 3 E (N ) B - 3 38 39 M + E 40 41 M + E 42 LO A D T Y P E P A N E L T O T A L FE E D T H R U TO T A L SU B F E E D TO T A L FE E D E R SU B T O T A L DE M A N D F E E D E R T O T A L GE N E R A L N O T E S : A. (L ) L I G H T I N G 0 0 12 5 % 0 B. (R ) R E C E P T A C L E S 0 0 NE C 2 2 0 0 C . (L M ) L A R G E S T M O T O R 0 0 25 % 0 D. (M ) M O T O R S ( A L L ) 0 0 10 0 % 0 E. (E ) E Q U I P M E N T 0 0 10 0 % 0 SP E C I F I C N O T E S : (A ) A P P L I A N C E S 0 0 00 (1 ) PA N E L T O T A L ( K V A ) : 0. 0 (2 ) (3 ) PA N E L T O T A L ( A ) : 0 (4 ) (5 ) ME C H A N I C A L E Q U I P M E N T S C H E D U L E MA R K D E S C R I P T I O N VO L T / PH A S E HP W A T T S F L A M C A M O C P DI S C O N N E C T / F U S E SI Z E FE E D E R C I R C U I T S P E C I F I C N O T E S B- 1 B O I L E R 2 0 8 / 3 1. 5 20 / 3 / N F 3# 1 2 , # 1 2 G R D P P A 2 - 2 0 , 2 2 , 2 4 B- 2 B O I L E R 2 0 8 / 3 1. 5 20 / 3 / N F 3# 1 2 , # 1 2 G R D P P A 2 - 2 6 , 2 8 , 3 0 B- 3 BO I L E R 2 0 8 / 3 1. 5 20 / 3 / N F 3# 1 2 , # 1 2 G R D P P A 2 - 3 8 , 4 0 , 4 2 GF - 1 G L Y C O L F E E D E R 1 2 0 / 1 1P M O T O R R A T E D SW I T C H 2# 1 2 , # 1 2 G R D PP A 2 - 3 6 BP - 1 P R I M A R Y B O I L E R C I R C 2 0 8 / 3 1. 5 20 / 3 / N F 3# 1 2 , # 1 2 G R D P P A 2 - 1 , 3 , 5 BP - 2 P R I M A R Y B O I L E R C I R C 2 0 8 / 3 1. 5 20 / 3 / N F 3# 1 2 , # 1 2 G R D P P A 2 - 7 , 9 , 1 1 BP - 3 PR I M A R Y B O I L E R C I R C 2 0 8 / 3 1. 5 20 / 3 / N F 3# 1 2 , # 1 2 G R D P P A 2 - 3 1 , 3 3 , 3 5 P- 5 SE C O N D A R Y B U I L D I N G HE A T I N G W A T E R 20 8 / 3 5 40 / 3 / N F 3# 8 , # 1 0 G R D P P A - 7 , 9 , 1 1 P- 6 SE C O N D A R Y B U I L D I N G HE A T I N G W A T E R 20 8 / 3 5 40 / 3 / N F 3# 8 , # 1 0 G R D P P A - 1 4 , 1 6 , 1 8 (E ) ( R ) P - 7 SE C O N D A R Y P E N T H O U S E MU A H E A T I N G W A T E R 20 8 / 3 5 40 / 3 / N F 3# 8 , # 1 0 G R D (E ) P P A - 2 , 4 , 6 ( 1 ) (E ) ( R ) P - 8 SE C O N D A R Y P E N T H O U S E MU A H E A T I N G W A T E R 20 8 / 3 5 40 / 3 / N F 3# 8 , # 1 0 G R D (E ) P P A - 8 , 1 0 , 1 2 ( 1 ) P- 1 4 S E C O N D A R Y H W H X C I R C 2 0 8 / 3 3 / 4 2 0 / 3 / 7 A F 3# 1 2 , # 1 2 G R D P P A 2 - 3 7 , 3 9 , 4 1 P- 1 5 S E C O N D A R Y H W H X C I R C 2 0 8 / 3 3 / 4 2 0 / 3 / 7 A F 3# 1 2 , # 1 2 G R D P P A 2 - 3 7 , 3 9 , 4 1 P- 1 6 S E C O N D A R Y H W H X C I R C 2 0 8 / 3 3 / 4 2 0 / 3 / 7 A F 3# 1 2 , # 1 2 G R D P P A 2 - 3 7 , 3 9 , 4 1 P- 1 7 S E C O N D A R Y H W H X C I R C 2 0 8 / 3 3 / 4 2 0 / 3 / 7 A F 3# 1 2 , # 1 2 G R D P P A 2 - 3 7 , 3 9 , 4 1 PD H R - 1 D O M E S T I C H O T R E C I R C 1 2 0 / 1 0 . 1 7 1P M O T O R R A T E D SW I T C H 2# 1 2 , # 1 2 G R D PP A 2 - 3 4 PD H R - 2 D O M E S T I C H O T R E C I R C 1 2 0 / 1 0 . 1 7 1P M O T O R R A T E D SW I T C H 2# 1 2 , # 1 2 G R D PP A 2 - 3 4 PD H R - 3 DO M E S T I C H O T R E C I R C 1 2 0 / 1 0 . 1 7 1P M O T O R R A T E D SW I T C H 2# 1 2 , # 1 2 G R D PP A 2 - 3 4 GE N E R A L N O T E S : A. S E E S P E C I F I C A T I O N S F O R E L E C T R I C A L D I V I S I O N A N D M E C H A N I C A L D I V I S I ON M O T O R S T A R T E R C O O R D I N A T I O N . B. P R O V I D E P H A S E P R O T E C T I O N F O R A L L T H R E E P H A S E M O T O R S A B O V E 7 - 1 / 2 H P . C. P R O V I D E A L L E X T E R I O R D I S C O N N E C T S W I T H N E M A 3 R R A T I N G . D. W H E N E Q U I P M E N T I S L I S T E D W I T H O N L Y A H O R S E P O W E R R A TI N G T H E D I S C O N N E C T A N D F E E D ER A R E S I Z E D P E R T H E N . E . C . SP E C I F I C N O T E S : (1 ) PR O V I D E N E W D I S C O N N E C T F O R R E L O C A T E D E Q U I P M E N T . (2 ) (3 ) (4 ) PA N E L 'P P A ' SE C . 1 SU B - PA N E L 80 / 3 LOAD JUSTIFICATION EQUIPMENT REMOVEDWATTS (D) BOILER 19108 (D) BOILER 29108 (D) P-19108 (D) P-29108 (D) P-31728 (D) P-41728 (D) P-56300 (D) P-66300 (D) P-76300 (D) P-86300 (D) P-141050 (D) P-151050 (D) PDHR-1528 (D) PDHR-2528 (D) PDHR-3528 (D) PDHR-4528 TOTAL LOAD REMOVED69300 EQUIPMENT ADDEDWATTS (N) B-12484 (N) B-22484 (N) B-32484 (N) GF-1100 (N) BP-12484 (N) BP-22484 (N) BP-32484 (N) P-56300 (N) P-66300 (N) P-141332 (N) P-151332 (N) P-161332 (N) P-171332 (N) PDHR-1528 (N) PDHR-2528 (N) PDHR-3528 TOTAL LOAD ADDED34516 AS DEMONSTRATED IN CALCULATIONS ABOVE,ABOVE, THE SCOPE OF THIS PROJECT REPRESENTS A NET LOAD REDUCTION.E2.0ELECTRICAL ONE-LINE DIAGRAM AND SCHEDULES3544.20 03/18/2014 SHEET TITLE:NO.Job no.:REVISION Drawn by:Date:Designed by:DATE BYEAUDINANZECOPYRIGHT 2013 BG Vail:Denver:Fort Collins:Albuquerque:Jackson:www.bgce.com(970)949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 S:\BGProjects\3544.20 Mountain Haus, Boiler Replacement\Cad\BGCE CAD\354420E20.dwg Printed By: eng-ntt March 18, 2014 - 2:01pm MOUNTAIN HAUS BOILER PLANT REPLACEMENT50% CONSTRUCTION DOCUMENTSZRW11.01.2013 NTTMBSPROGRESS PRINTZRW03.13.2014 VAIL'S MOUNTAIN HAUS AT THE COVERED BRIDGE 292 EAST MEADOW DR. VAIL, CO 81657100% CD / PERMITZRW03.18.2014