HomeMy WebLinkAboutB14-0025 plans APPROVED OWNER VAIL VALLEY MEDICAL CENTER .■■ . . NOTE: CONTRACTOR TO COORDINATE STAGING, STORAGE, PARKING, CONSTRUCTION ACCESS AND ADJ. ADJUSTABLE MECH. MECHANICAL 181 WEST MEADOW DRIVE RELATED ISSUES WITH THE OWNER PRIOR TO COMMENCING WORK. A.F.F. ABOVE FINISH FLOOR MIN. MINIMUM APPLICABLE BUILDING CODE: 2012 INTERNATIONAL BUILDING CODE VAIL, COLORADO 81657 ■■ . ■ - 2012 INTERNATIONAL MECHANICAL AND UNIFORM PLUMBING CODE ■ . AL. A�UMINUM MTL. METAL CONTACT: RYAN MAGILL(970)904-0066 ■ 1. ERECT AND MAINTAIN DUST-PROOF PARTITIONS AND CLOSURES AS REQUIRED AND OUTLINED BY THE 2012 INTERNATIONAL FIRE CODE ■ . B.O. BY OWNER NO. NUMBER HOSPITAL TO PREVENT SPREAD OF DUST, NOISE AND FUMES TO OCCUPIED PORTIONS OF THE BUILDING 2012 INTERNATIONAL PLUMBING CODE AND TO PROVIDE FREE AND SAFE PASSAGE OF PERSONNEL AND GENERAL PUBLIC TO AND FROM CFT. CERAMIC FLOOR TILE O.C. ON CENTER 2012 INTERNATIONAL FUEL GAS CODE ARCHITECT DAVIS PARTNERSHIP, P.C. ■ . ■ - OCCUPIED PORTIONS OF THE BUILDING. CONC. CONCRETE P. PAINT 2012 INTERNATIONAL ENERGY CONSERVATION CODE 0225 MAIN STREET, UNIT C101 . CONT. CONTINUOUS P. LAM. PLASTIC LAMINATE 2012 INTERNATIONAL PERFORMANCE CODE EDWARDS, COLORADO 81632 ■ ■ ■ ■■ 2. GENERAL CONTRACTOR TO PROVIDE PROTECTION FROM DAMAGE DURING DEMOLITION AND CORR. CORRIDOR RB. RUBBER BASE 2011 NATIONAL ELECTRICAL CODE CONTACT: SCOTT NEVIN, AIA(970)926-8960 CONSTRUCTION WORK TO FLOOR AND FINISHED SURFACES TO REMAIN. CONTRACTOR SHALL MINIMIZE COORD. COORDINATE RE: REFER TO 1997 EDITION OF THE UNIFORM CODE FOR THE INTERFERENCE OF CONSTRUCTION WITH ONGOING BUSINESS. CONTRACTOR TO CONTACT OWNER A ABATEMENT OF DANGEROUS BUILDING MINIMUM OF SEVEN DAYS PRIOR TO COMMENCING DEMOLITION TO SCHEDULE WORK. C.M.U. CONCRETE MASONRY UNIT REF. REFRIGERATOR MECHANICAL/ BEAUDIN GANZE CONSULTING ENGINEERS CPT. CARPET RM. ROOM OCCUPANCY CLASSIFICATION: BUSINESS B ABOVE GRADE ELECTRICAL 222 CHAPEL PLACE, UNIT AC-201 DAV I S 3. CONTRACTOR SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS AND CWT. CERAMIC WALL TILE R.O. ROUGH OPENING STORAGE S-2 BELOW GRADE ENGINEER P.O. BOX 9650 DEBRIS. REMOVE PROTECTIONS AT COMPLETION OF WORK. PROMPTLY REPAIR DAMAGES CAUSED TO D.W. DISHWASHER S.F. SQUARE FEET AVON, COLORADO 81620 ADJACENT FACILITIES BY DEMOLITION AND/OR CONSTRUCTION WORK AT NO COST TO THE HOSPITAL. EA. EACH SIM. SIMILAR OCCUPANCY CONTACT: DAN KOELLIKER(970)949-6108 PA RT N E RS H I P „ , ELEC. ELECTRIC S.S. STAINLESS STEEL SEPARATIONS REQUIRED: NONE 4. DO NOT SCALE DRAWINGS. TYPICAL'AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE ELEV. ELEVATION STD. STANDARD A R C H I T E C T S CONDITION IS THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS, UNLESS OTHERWISE GENERAL CONTRACTOR: JACKSON BUILDING COMPANY NOTED. DETAILS ARE USUALLY KEYED AND NOTED "TYPICAL" ONLY ONCE WHEN THEY FIRST OCCUR EQ. EQUAL STDS. STANDARDS ACCESSORY USE AREAS: NONE P.O. BOX 6625 AND ARE REPRESENTATIVE OF ALL SIMILAR CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED. EQUIP. EQUIPMENT STRUCT. STRUCTURE VAIL, COLORADO 81658 I2301 Blake Street, Suite 100 EXT. EXTERIOR SUSP. SUSPENDED Denver Denver, CO 80205 303.861.8555 5. THE CONTRACTOR SHALL MAINTAIN THE EXISTING STRUCTURAL AND FIREPROOFING INTEGRITY EXIST. EXISTING (TYP.) TYPICAL INCIDENTAL USE AREAS: NONE CONTACT: BRICE JACKSON (970)331-6800 THROUGHOUT THE ENTIRE PROJECT AREA. PROVIDE ELECTROLYSIS PROTECTION BETWEEN ALL 0225 Main Street, Unit C101 DISSIMILAR METALS,WHERE THEY OCCUR.ALL EXISTING STRUCTURE TO REMAIN. F.D. FLOOR DRAIN TREAT. TREATMENT VaillEdwards, CO 81632 970.926.8960 GA. GAUGE U.C. UNDER COUNTER/CABINET 6. THE OWNER SHALL BE CONTACTED IN REGARDS TO ANY SALVAGEABLE MATERIAL OR EQUIPMENT. GALV. GALVANIZED U.C.L. UNDER CABINET LIGHT CONSTRUCTION TYPE: TYPE V B ANY SALVAGEABLE ITEMS NOT TO BE REUSED OR WANTED BY OWNER SHALL BECOME PROPERTY OF GYP. BD. GYPSUM BOARD U.N.O. UNLESS NOTED OTHERWISE •� " � THE CONTRACTOR. G.C. GENERAL CONTRACTOR V.I.F. VERIFY IN FIELD ALLOWABLE BUILDING AREA 9,000 SQUARE FEET ALLOWED 7. CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING IN WALLS TO RECEIVE ALL ATTACHED HGT. HEIGHT VCT. VINYL COMPOSITION TILE PER FLOOR: 200% SPRINKLER INCREASE BEAUDIN GANZE CONSULTING ENGINEERS EQUIPMENT, PLUMBING FIXTURES, MILLWORK, CASEWORK, ETC. NOTE: ALL FRAMING OR CONCEALED H.M. HOLLOW METAL W/ WITH 27,000 SQUARE FEET PER FLOOR ADJUSTED ALLOWABLE 222 CHAPEL PLACE, UNIT AC-201 BLOCKING SHALL BE 18 GAUGE SHEET METAL. FACILITY TO BE JCAHO COMPLIANT; JCAHO LIFE SAFETY HR. HOUR P.O. BOX 9650 WB. WOOD BASE AVON, COLORADO 81620 GUIDELINES SUPERSEDE IBC AND LOCAL JURISDICTION'S AUTHORITY, SO NO EXCEPTIONS FOR INSUL. INSULATION WD. WOOD 970.949.6108 NON-COMBUSTIBLE WOOD BLOCKING WILL BE ALLOWED. ACTUAL BUILDING AREA *TYPICAL ABBREVIATIONS. MAY NOT BE USED IN THE DRAWINGS. GROUND FLOOR: 9,677 GSF 8. PROVIDE SEALANT AROUND ALL PLUMBING FIXTURES WHERE THEY ABUT ADJACENT SURFACE. PER FLOOR: SECOND FLOOR: 9,141 GSF 9. CONTRACTOR SHALL PATCH, REPAIR AND PAINT WALLS, FLOOR AND CEILING AS REQUIRED o.o ABBREVIATIONS THIRD FLOOR: 9,197 GSF o o PARTICIPANTS FOLLOWING DEMOLITION OF EXISTING PARTITIONS AND EXISTING FINISHES. ACTUAL TENANT AREA: 21,338 NSF 10.ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR THE PROPER EXECUTION OR INSTALLATION, OR PERFORMANCE OF THE WORK, SHALL BE PROVIDED BY THE 125 DOOR IDENTIFIER SHEET SHEET NAME REV.# REV.# REV.# REV.# REV.# CONTRACTOR.THE CONTRACTOR SHALL PERFORM HIGH QUALITY, PROFESSIONAL WORK. MATERIALS TOTAL BUILDING AREA: 28,015 GSF SHA�L BE JOINED IN A MANNER TO PROVIDE A UNIFORM,ACCURATE FIT; W�TH NEAT STRAIGHT LINES, OFFICE NEW ROOM FREE OF SMEARS OR OVERLAPS. INSTALL EXPOSED MATERIALS APPROPRIATELY LEVEL, PLUMB,AND 000 IDENTIFIER ARCHITECTURAL AT ACCURATE ANGLES, OR FLUSH WITH ADJOINING MATERIALS. REMODEL AREA: 3,767 SF A0.0 I GENERAL INFORMATION INTERIOR ELEVATION A0.1 I SPECIFICATIONS I 11. WHERE PLUMBING FIXTURES, PIPING, MEDICAL GASES, ELECTRICAL FIXTURES, MECHANICAL "��� � REFERENCE EQUIPMENT, OR ANY OTHER EQUIPMENT IS REMOVED,ALL PIPING AND/OR CONDUITS THAT ARE ALLOWABLE BUILDING HEIGHT: TWO STORIES/40 FEET ALLOWED A0.2 DOOR HARDWARE, FRAMES, SCHEDULES,AND DETAILS I ABANDONED SHALL BE CAPPED OFF BELOW THE FLOOR INSIDE WALLS OR ABOVE CEILINGS AS ONE STORY/20 FEET WITH SPRINKLER INCREASE A0.3 INTERIOR FINISHES AND SCHEDULE APPROPRIATE. O KEY NOTE TAG THREE STORIES/60 FEET ADJUSTED ALLOWABLE AR2.0 I LIFE SAFETY PLAN AND NOTES AD2.0 DEMOLITION PLAN, LEGENDS AND NOTES 12. CONTRACTOR SHALL VISIT THE SITE AND BECOME COMPLETELY FAMILIAR WITH ALL EXISTING ACTUAL BUILDING HEIGHT: FRONT: THREE STORIES/43'-4"TO PEAK/39'-9"TO PARAPET A2.0 NEW CONSTRUCTION PLAN, LEGENDS AND NOTES CONDITIONS PRIOR TO SUBMITTING PRICES AND STARTING WORK. THE CONTRACTOR SHALL NOTIFY � 4�_58�� DIMENSION LINE REAR: FOUR STORIES/61'-1" A7.0 INTERIOR ELEVATIONS THE ARCHITECT OF ANY CONDITIONS OR DISCREPANCIES ADVERSELY AFFECTING THE DESIGN � � A7.1 INTERIOR ELEVATIONS INSTALLATION PRIOR TO PROCEEDING WITH THE WORK(INCLUDING CONFLICTS W�TH MECHANICAL PARKING REQUIREMENTS: 21,338/150=143 : DUCTS, STRUCTURE, PIPING, CONDUIT RUNS, MECHANICAL UNITS, LIGHT FIXTURES, CEILING FEATURES ` -� � DETAIL IDENTIFIER HANDICAP REQUIREMENTS: 5/(IBC) A8.0 INTERIOR DETAILS OF FLOOR BELOW, FIRE SPRINKLERS LINES OR HEADS, ETC.)WHETHER EXISTING OR NEW. A1.1 A9.0 REFLECTED CEILING PLAN, LEGEND AND NOTES ACTUAL SPACES: SURFACE:21 13. GENERAL CONTRACTOR TO PROTECT AND CLEAN ANY EXISTING SURFACES WITHIN SCOPE OF WORK WALL TYPE TAG GARAGE: 77 THAT ARE TO REMAIN. � HANDICAP SPACES: SURFACE: 3 GARAGE:2 MECHANICAL 14. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND M0.0 MECHANICAL COVER SHEET ENGINEERING DRAWINGS, SPECIFICATIONS, OR EXISTING CONDITIONS. � DETAIL SECTION FIRE PROTECTION: FULLY SPRINKLERED M0.1 MECHANICAL SCHEDULES � - � - •� �, - 1►� IDENTIFIER Ai.i PROJECT DESCRIPTION: RECONFIGURATION OF OFFICE SPACE. M0.2 � MECHANICAL SPECIFICATIONS I � 15. CONTRACTOR TO CAREFULLY REVIEW AND ASSESS THE VARIOUS SLAB CONDITIONS AND MD1.0 I MECHANICAL DEMO PLAN I I I � \\ COORDINATE FLOOR PATCHING AND ADDITIONAL PREPARATION WITH FINISH TO BE WSTALLED; REFER OF C� M1.0 HVAC PLAN � A� TYPICAL SYMBOL DESIGNATIONS. M2.0 PLUMBING PLAN TO A0.1 FOR SPECIFICATION GUIDELINES� I ,� ��O �� MAY NOT BE USED IN THE DRAWINGS. I ��Q- ��� ` ��Q 16. CONTRACTOR TO SCHEDULE A CHALK WALK WITH THE ARCHITECT AND OWNER TO CONFIRM WALL M3.0 MECHANICAL DIAGRAMS � LAYOUT. CONTRACTOR TO SCHEDULE AN ELECTRICAL BOX WALK WITH THE ARCHITECT AND OWNER. 3 4 M3.1 MECHANICAL CONTROLS SCOTT MICHAEL � CONTRACTOR TO SCHEDULE A FINAL PUNCH WALK WITH THE ARCHITECT AND OWNER. IF MORE THEN � � SYM BO LS p p B U I LD I N G COD E I N FORMATI ON * NEVIN * EOXPE SESH LIST WALK THRU IS REQUIRED, CONTRACTOR IS TO COMPENSATE FOR ARCHITECT'S I I __ I I � 202985 ���,j � ELECTRICAL I I I �� ��.�`V 17. THE PRESENCE OF THE ARCHITECT OR REPRESENTATIVE ON THE JOB SITE DOES NOT IMPLY INSULATION : E0.0 I ELECTRICAL COVER SHEET I I I � � CONCURRENCE OR APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL SPECIFIC ITEMS IN �� CONSTRUCTION RATING E0.1 � ELECTRICAL SPECIFICATIONS I I I 3/3/20 � A�� WRITING TO THE ATTENTION OF THE ARCHITECT TO OBTAIN THE ARCHITECT'S APPROVAL. NO CHANGES � � � � � �X `� � `� Y� � � �/ � �X _ E1.0 ELECTRICAL POWER PLAN - TO THE CONTRACT CAN BE MADE WITHOUT THE OWNER'S CONTACT WRITTEN APPROVAL. ' \/ ' � % � �� � � �� � j � � r, STRUCTURAL FRAME 0 HR E2.0 � ELECTRICAL LIGHTING PLAN � � ;� y� 1 ti �� � �' ;( � � 18. THE CONTRACT DOCUMENTS ARE THE RESPONSIBILITY OF ALL TRADES IN THEIR ENTIRETY. WHERE (INCLUDING COLUMNS, E3.0 ELECTRICAL ONE-LINE DIAGRAM REQUIREMENTS ARE SHOWN IN ONE SECTION OF THE SPECIFICATIONS OR DRAWINGS BUT NOT �� E3.1 ELECTRICAL DIAGRAMS ' � - � • r� . • � ANOTHER, THE CONTRACTOR OR SUBCONTRACTOR IS NOT RELIEVED FROM PROVIDING COMPLETELY WALL TYPE 1 GIRDERS,AND TRUSSES) FINISHED AND PROPERLY FUNCTIONING SYSTEMS. 3 s" METAL STUDS WITH 1 LAYER s"GYPSUM BOARD, BOTH SIDES I I EXTEND GYPSUM BOARD, INSULATION AND STUDS TO DECK. BEARING WALLS 19. ALL WORK UNDER THIS CONTRACT TO BE IN STRICT ACCORDANCE WITH REGULATIONS FOR CONTRACTORS PERFORMING WORK AT THE HOSPITAL AS FOLLOWS: LEAD LINING EXTERIOR 0 HR Vail A. PROVIDE OWNER WITH LIST OF ALL SUBCONTRACTORS, CONTACTS AND TELEPHONE NUMBERS. �� B. CONSTRUCTION HOURS ARE 7:00 AM TO 5:00 PM, MONDAY THROUGH FRIDAY UNLESS OTHERWISE INTERIOR 0 HR Vall� APPROVED BY THE OWNER,WITH AT LEAST 48 HOURS ADVANCE NOTICE. � ' "' � � � r '� , '' " � � " '"� - V C. CONTRACTOR IS RESPONSIBLE FOR BAGGING ALL SMOKE DETECTORS AND IS RESPONSIBLE FOR ANY N� �,' ' � � x � � � � �� r � � � aI COSTS INCURRED FROM DAMAGE TO ALARMS DUE TO DUST OR ANY OTHER CONSTRUCTION ACTIVITY. NONBEARWG WALLS AND PARTITIONS M��1C�1� D.ANY WORK ON THE FIRE PROTECTION SYSTEM OR FIRE ALARM SYSTEM MUST BE COORDINATED ' EXTERIOR 0 THROUGH THE OWNER AND LOCAL FIRE DEPARTMENT. WALL TYPE 2 � E. CONTRACTOR SHALL NOT SHUT OFF OR PUT OUT OF SERVICE ANY SYSTEM/SERVICES WITHOUT FIRST INTERIOR 0 I ; Center COORDWATING WITH THE OWNER AT LEAST 72 HOURS IN ADVANCE. 3 �" METAL STUDS AT 1 6" O.C. WITH 1 LAYER $�" GYPSUM BOARD, BOTH SIDES II F. CONTRACTOR SHALL COORDINATE ALL WELDING VENTING,AND TIMES OF DEMOLITION AND EXTEND GYPSUM BOARD 6 ABOVE FINISHED CEILING U.N.O. ` �� CONSTRUCTION WITH THE OWNER AND CONCURRENT OCCUPANCY OF THE BUILDING. LEAD LINING PER PHYSICIST'S REPORT; X-RAY ROOM S1DE OF WALL. FLOOR CONSTRUCTION 0 HR 20. DIMENSIONS OF AND FROM EXISTING CONDITIONS HAVE BEEN TAKEN FROM EXISTWG DRAWINGS (INCLUDWG SUPPORTING BEAMS I AND/OR FIELD MEASUREMENTS. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PERTAINING NOTES: AND JOISTS) TO EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. 1. PROVIDE SOUND ATTENUATION BATTS IN ALL NEW WALLS (TYPICAL). Vai I S u m m it 2. PROVIDE 6"STUD BEHIND TOILETS AND WHERE FINISHED DIMENSION OF WALL 7 1/4". 6 D RAW I N G I N D EX 21. NOTIFY ARCHITECT OF ANY DISCREPANCIES UNCOVERED BY DEMOLITION; OR IF EXISTING 3. DELETE INTERIOR LAYER OF GYPSUM BOARD AT COLUMN FURRING. �•� Orthopaed ics CONDITIONS PREVENT LAYOUT FROM PROVIDING PROPER CLEARANCES. 4. PROVIDE WALL TYPE 1, UNLESS NOTED OTHERWISE. ROOF CONSTRUCTION 0 HR 5. REFER TO PHYSICIST'S REPORT FOR AMOUNT AND AREAS TO RECEIVE LEAD LINING AT X-RAY ROOM. (INCLUDING SUPPORTING BEAMS 22. CONTRACTOR TO REPAIR ANY DAMAGE FROM REMOVING EXISTING FINISHES OR WALLS TO INSURE THAT SURFACE IS SMOOTH AND PREPPED FOR PAINTING AND WALL COVERING. PROVIDE THE MINIMAL AND JOISTS) US Bank Building RECEIVE N W FI NISH EXISTING WALLS OR DAMAGED WALLS CANNOT BE PROPERLY PREPARED TO �� TYPICAL WALL TYPE Suite 206 SHAFTS *1-2HR SITE LOCATION 23. REVIEW DEMOLITION OF AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH STRUCTURAL (INCLUDING ELEVATOR) 108 South Frontage Road ENGINEER WHERE POTENTIAL OF ENCOUNTERING BEARING MEMBERS OR REINFORCEMENT EXISTS. VaII, COIOf aCIO 81657 NOTIFY ARCHITECT IF EXISTING ASSEMBLIES DESIGNATED AS RATED REQUIRE MODIFICATION. SCOPE OF WORK EXIT STAIR ENCLOSURES *2 HR � _ � � � � W�ST VAIL I ' ' I • 11. � I � � � � MAiN vAi� �xiT NORTH �� ��-i.. � _ _� �' *EXISTING CONDITION DOES NOT COMPLY. Slle@t TItIe: _ _,_s��� ��/�j I1��'�'�S _ fq � 1'`�T wESl ����� ��oNlq�E Roq�� �IC���� � ��sr vAi�_- � � ��'�,-- � G� M�q��w � O �� RE ��,�� � GENERAL NOTES t�.. P� � �' �E� � MEAD Eqsr � I� � C� EPS �W DRIVE M����W �RIVE � � � � � � � � � � � P� R � BRIDGE �� � � BEAVER � �q0 0 �4,, ' o R�AD� w _ I II� _ \ o Permit Set 3/3/2014 � GORE m CREEK �wi��ow RoA� Sheet Number: I -.-..,���-�1�� . �< � .. � .� �_.. F��.Sj ROAD F�RES7 ROAD WILLOW R PLACE ��O I HANSON /�q ROPG l`� R��KLED�E N�/y � � � � RqqG 0 °o � N T = o.o GENERAL NOTES o.o SCOPE OF WORK o.o CONSTRUCTION RATING INFORMATION o o VICINITY MAP NTS DPA Project: 14901.00.000 � 0 COPYRIGHT 20�4-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ GENERAL REQUIREMENTS Concrete Toppings: Acoustical Panel Ceilings: ■■ . ■ - Provide self-leveling underlayments complying with the requirements of ASTM C94 over existing base slab so as to provide a smooth and level surface to receive finished Submit Product Data and Material Samples. Summary of Work: flooring materials. Remove dirt, loose material, oil, grease, paint or other contaminants from existing concrete slab leaving a clean surface to receive topping slab. Repair all cracks in existin concrete floor slab to minimize tele ra hin Prime existin floors in accordance with he re uirements of the manufacturer. Trowel floor to roduce a Acoustical Panel Ceilings: Comply with ASTM E 1264 for Class A materials, as determined by testing identical products per ■ . ■ The work consists of interior renovation with mechanical and electrical work, as described in the Contract Documents. g g p g� g a p ASTM E 84. ■ , finished surface free of trowel marks, uniform in texture and appearance and achieving the following tolerances when tested in accordance with ASTM E 1155. ■ . ■ . - Manufacturer: Ardex, Inc. Ceiling Suspension Systems: Contractor's Use of Premises: Direct-hung suspension system, with intermediate-duty structural classification according to ASTM C 635. During construction, Contractor shall have limited use of space indicated. Contractor's use of premises is limited only by Owner's right to perform work or employ other Size attachment devices for 5 times the design load indicated in ASTM C 635, Table 1, Direct Hung, unless otherwise indicated.ce ■ ■ ■ ■■ �or,tra�tors on po�t�ons ot pro�e�t. Interior Architectural Woodwork: Zinc-coated carbon-steel wire hangers, braces, and ties complying with ASTM A 641 (ASTM A 641M), Class 1 zinc coating, soft temper. Contract Modification Procedures: Upon the Owner's approval of a proposal from the Contractor, submitted either in response to a Proposal Request issued by the Architect or Submit Shop Drawings and Samples specified. Submittal to include fastening/assembly methods, all joinery details per AWI 400 G 10 AWI standards, locations, dimensions, Installation: as a request for change from the Contractor,the Architect will issue a Change Order on AIA Document G701,for all changes to the Contract Sum or Contract Time. finishes and rough-in for MEP devices. Dimensions on shop drawings to match dimension point of architectural drawings. CISCA's "Ceiling Systems Handbook." Payment Procedures: Quality Standard: Architectural Woodwork Institute's"Architectural Woodwork Quality Standards." Flush overlay. WIC Construction Style: Style A, Frameless.WIC Door and CISCA's "Recommendations for Direct-Hung Acoustical Tile and Lay-in Panel Ceilings." Submit a Schedule of Values which breaks down the Contract Sum into at least one line item for each technical Specification Heading. Correlate the Schedule of Values with Drawer Front Style: Flush overlay. D�� I � the Contractor's Construction Schedule. Gaps between doors/drawers to be equal and orthogonal. ASTM C 636, "Standard for Ceiling Suspension System Installations." Materials: U.B.C. Standard 47-18. Submit 3 notorized copies of each Application for Payment on AIA Document G702/703, in accordance with the schedule established in the Agreement. All rid to be Armstron 15/16" relude xl ex osed tee s stem; Wh�te. PA RT N E RS H I P For the Application submitted at Substantial Completion, submit partial releases of liens from each subcontractor or supplier for whom amounts were requisitioned on the Hardboard: AHA A135.4 9 9 p p Y previous payment. Medium-Density Fiberboard: ANSI A208.2 Particleboard: ANSI A208.1, Grade M-2 Car @t: Coordination: p R C H I T E C T S Hardwood Plywood and Face Veneers: HPVA HP-1 Submit Product Data and Color Sam les. Progress meetings will be held at Project site every two (2)weeks. Owner, Architect, Contractor and each subcontractor or other entity concerned with current progress or P High-Pressure Laminate Grade: Grade 51-General Purpose (HGS, nominal thickness 0.050"/1.2mm). Pre floor as re uired and install a self-levelin com ound see Concrete To in Slab section above to rovide a flat and level finished surface. involved with planning or coordination of future activities, shall attend. Minutes of each meeting will be prepared by Contractor and distributed to all parties present. Contractor p a g p � pp g � p Grain Direction: Parallel to cabinet fronts. Installer Qualifications: En a e an ex erienced Installer who is certified b the Floor Coverin Installation Board FCIB or who can demonstrate com liance with FCIB 2301 Blake Street, Suite 100 to provide progress schedule at each OAC meeting indicating project work for the next three weeks. Ed e Treatment: PVC ed es if match available for counter laminate: refer to drawin s and cut on cabinet surfaces. g g p y g � � p Denver g g g certification program requirements. Denver, CO 80205 303.861.8555 Submittal Procedures: Adjustable Shelving: Shelf standards: K&V 255NV Brackets: K&V 256NP with melamine shelves, length of wall indicated, six shelves high. Coordinate submittal re aration with construction schedule,fabrication lead-times, other submittals and activities that re uire se uential o erations. Carpet that have flame-spread and smoke-developed ratings of 25 or less and 450 or less, respectively,when tested according to ASTM E 84. Comply with CRI 104, p p q q P Countertops: Plastic Laminate by Wilsonart Laminate or equal, .048"thick. I0225 Main Street, Unit C101 Section 6, "Site Conditions." Vail No extension of Contract Time will be authorized due to failure to transmit submittals in time to permit processing sufficiently in advance of when materials are required in the Cabinet Interiors: White Melamine; unless noted otherwise Edwards, CO 81632 970.926.8960 Work. Architect to have seven working days to process submittals, unless agreed to by Architect. No product may be substituted or assumed as equal; all deviations from Contact Adhesive: Provide Laminate manufacturer recommendation for the application. At completion of project, deliver to Owner full-width carpet equal to 5 percent of each type and color carpet installed, packaged with protective covering for storage. s ecified roducts must be formall submitted in writin for a roval b Architect and Owner;written a roval issued via AIA documents. Cost for re lacin and work disturbed Plastic laminate to be a lied to all ex osed surfaces unless otherwise noted. Caulk all 'oints where casework meets wall. Seam fill all 'oints at underside of u er cabinets. Provide carpet as scheduled on the Drawings. p p y g pp y pp p g pp p > > pp Comply with CRI 104, Section, "Direct Glue-Down." �� � � by installation of unapproved substitution by Contractor. Casework to be installed level. Underside of upper cabinets to be installed at filler pieces, corners,and panels. ' Prepare submittals by placing a permanent label on each for identification. Provide label to record review and approval markings and action taken. Include the following Resilient Wall Base and Accessories: information on the label: �nterior Wood Trim: BEAUDIN GANZE CONSULTING ENGINEERS Pro ect Name o Submit Product Data and Color Samples. 222 CHAPEL PLACE, UNIT AC-201 J Trim: 6/o moisture content,warp free; white maple; plain sliced with transparent coating to match doors. Nail and screw size and type appropriate. At completion of project, deliver to Owner at least 10 linear feet for each 500 linear feet or fraction thereof, of each type and color of resilient wall base Date Installation: Mitre all joints; no cracks or rough surfaces. P.O. BOX 9650 Name and Address of Contractor installed. AVON, COLORADO 81620 Name and Address of Subcontractor and Supplier Provide resilient rubber wall base and accessories per finish schedule. 970.949.6108 Cabinet Hardware and Accessories: Apply resilient rubber wall base to walls in 80 feet lengths, columns, pilasters, casework, and other permanent fixtures in rooms or areas where base is Title of Appropriate Technical Specification Heading Hinges: Blum 706500 F5 FO with Mounting Plate 175H7100 required. Form wall base corners from straight pieces. Install reducer strips at edges of flooring at dissimilar materials and exposed concrete floors. Roppe Product Data: Submit(3)three copies and mark each copy to show applicable choices and options. Pulls: 4" Brushed Wire pulls. Ives by Schlage, No. 137 US32D. No. 60 or Johnsonite No. CCA-XX Tile - Carpet Joiner between tile and carpet. Shop Drawings: Drawer guides: Accuride Medium Duty3832 easy glide slide with zinc finish. 125 degree opening. Submit newly prepared information drawn to scale. Contractor to indicate deviations from Contract Documents, including any addenda or change to the scope of the Locks: Disc Tumbler Cylinder Cam Locks. National Cam Locks. original scope of work. Do not reproduce Contract Documents or copy standard information. Submit 1 reproducible print and 1 blue-or black-line print on sheets at least 8-1/2 Exposed Hardware Finishes: For exposed hardware, provide finish that complies with BHMA A156.a8; provide BHMA 619/US 15, BHMA 626/US 26D, BHMA 625/US 26, or Y 9 Y P P P BHMA630/US 32D; unless noted otherwise. Sheet Vin I Floorin : b 11 inches but no lar er than 30 b 42 inches. Architect will return the re roducible rint. Contractor to absorb all costs associated with correction of substituted roduct if y g deviation from Contract Documents not brought to Owner's and ArchitecYs attention. Furring, Blocking, Shims and Hanging Strips: Metal.or fire retardant treated only. No combustible material may be used. Submit Product Data and Color Samples. Refer to A0.3 for manufacturer and colors. Refer to A1.0 for location. Samples: Submit(3)three sample finishes as specified and identical with the material proposed. Where variations are inherent in the material, submit at least(3)three units Prep floor as required and install a self-leveling compound (see Concrete Topping Slab)to provide a flat and level finished surface. Remove all debris, that show limits of the variations. Provide shop drawings for the following items: Doors and Frames, Door Hardware, Casework, Casework Hardware, Casework Finishes, substances and other foreign materials. Install in strict accordance with manufacturer's written instructions with a minimum of seams over approved subfloor. Joint Sealants: Perform moisture and concrete PF test rior to delive and installation of floorin testin and results to meet manufacturer's standards. Provide Paint, Acoustical Ceiling Tiles and Grid,tile, rubber base, carpet,wall protection and VCT. Include product name or name of the manufacturer. Architect will review each p �' g� g submittal, mark as appropriate to indicate action taken, and return copies less one retained. Submit Product Data and color Samples. manufacturer's standard warranty. Adhesive and heat-welded seams as recommended by the manufacturer. Compatibility: Provide joint sealants,joint fillers, and other related materials that are compatible with one another and with joint substrates under service and application Temporary Facilities and Controls: conditions. Standards: Comply with NFPA 241, "Standard or Safeguarding Construction, Alterations, and Demolition Operations;ANSI A10 Series standards for"Safety Requirements for Latex Sealant: At perimeter of door frames, plumbing fixtures and casework to walls (recess bead so that clear silicone bead can be applied on top). Pecora AC-20 one part Tile: Construction and Demolition"; and NECA Electrical Design Library's"Temporary Electrical Facilities." Electrical service shall be in accordance with NEMA NECA and UL acrylic latex caulk or equal. Floor Tile,wall tile& pattern per finish schedule. Provide epoxy floor tile grout. Hydroment no.425 acrylic latex grout or equal at walls. standards and regulations for temporary electric service. Install service in compliance with NFPA 70. Elastometric Sealant: Comply with ASTM C 920. Setting Materials: Hydroment"Single-Flex 916" latex modified dryset mortar and waterproof inembrane by Bostik Findley. Temporary Utilities: Acrylic Sealant: One-part, non-sag, solvent-release-curing acrylic terpolymer sealant complying with AAMA 808.3 or FS TT-S-00230, or both,with capability,when tested per Existing floor to be prepped to insure flush, smooth floor. Float floor with consistent slope to floor drains where required. Use of the Owner's existing sanitary facilities will be permitted, so long as facilities are cleaned and maintained in a condition acceptable to the Owner. At Substantial ASTM C 719,to withstand plus or minus 12.5 percent change in joint width existing at time of application without failing. Provide 5/"denzshield, or equal behind tile at walls. Completion, restore these facilities to the condition prevalent at the time of initial use. Acrylic-Emulsion Sealant: One-part, non-sag, mildew-resistant, paintable, acrylic-emulsion sealant complying with ASTM C 834. Temporary Controls: Silicone-Emulsion Sealant: At cap strip of integral sheet vinyl floor and adjacent surface. Product complying with ASTM C 834 and, except for weight loss measured per painting: Maintain existing fire protection until modified system of fire-protection is in place. ASTM C 792,with ASTM C 920,that accommodates joint movement of not more than 25 percent in both extension and compression for a total of 50 percent. Dow Corning 790 Silicone Building Sealant or equal. Submit Product Data and prepared Color Samples. Provide temporary barricades,warning signs, and lights to protect the public and construction personnel from construction hazards. At completion of project, deliver to Owner a 1-gal. (3.8-L)container, properly labeled and sealed, of each color and type of finish coat paint used on Project. Product Requirements: Acoustical Sealant: Non-sag, paintable, non-staining, latex sealant complying with ASTM C 834. Acoustical Sealant for Concealed Joints: Non-drying, non-hardening, non-skinning, non-staining, gunnable, synthetic rubber sealant recommended for sealing interior Paint: Manufacturer's first-line quality paint material of the various coating types as specified and as indicated on the finish plan. The Owner and Architect may consider substitutions of specified materials which provide a savings in Contract Sum and/or Time. The Contract Sum and Time savings shall be concealed �oints to reduce transmission of airborne sound. Comply with paint manufacturer's written instructions for surface preparation, environmental and substrate conditions, product mixing, and application. identified at time of submittal. The request for substitution shall be submitted in reasonable and timely manner for review, as not to delay construction. Substitution submittals � Exterior: provide compressive filler strip between new sidewalks and existing sidewalks, and between new foundation wall and new/old sidewalks. Interior Paint Schedule: shall include product information,test data, samples (if applicable), delivery time, and cost information. If deemed acceptable by the Owner and Architect, the substitution submitted may be used by the Contractor. Acceptance of the substitution by the Owner and Architect does not relieve the Contractor of responsibility in performance or A. Gypsum Board Substrates: workmanshi in relation to the substitution. The re uired warranties of an item of construction shall not be modified b substitutions. Hollow Metal Doors and Frames: p q Y Y 1. Lusterless (Flat) Emulsion Finish System: Two coats. Examination and Preparation: Submit Product Data and Door Schedule. � ��� Interior poor Frames: Provide units with mitered or coped and continuously welded corners formed from 0.0478-inch thick, cold-rolled steel for openings 48 inches or less in a. Primer: White, interior, latex-based primer: - . - •� I�Y.j�� \ • Examine substrates and conditions for compliance with manufacturer's written requirements including, but not limited to, surFaces that are sound, level and plumb; substrates (1) Moore: Moorcraft Super Spec Latex Enamel Undercoater and Primer Sealer#253. --- width and from 0.0598-inch steel for openings more than 48 inches in width. For rated doors and pairs of doors only provide "heavy duty" knock down hollow metal frames at �_ within installation tolerances; surfaces that are smooth, clean and free of deleterious substances; and application conditions within environmental limits. Do not proceed with (2) S-W: PrepRite 200Latex Wall Primer B28W200. � \ all other standard door frames. Provide one floor clip perjamb,4 metal stud anchors perjamb. % installation until unsatisfactory conditions have been corrected. Prepare substrates and adjoining surfaces according to manufap cturer's written instructions. (3) KWAL:118000 EnviroKote Interior Zero VOC Primer/Sealer. OF C�� Cutting and Patching: Prepare doors and frames to receive mortised and concealed hardware according to SDI 107. ' Q Comply with NAAMM's"Metal Finishes Manual for Architecture and Metal Products"for recommendations relative to applying finishes. � �� Before cutting/patching existing surfaces, examine surfaces to be cut and patched and conditions under which cutting and patching is to be performed.Take corrective action b. Finish Coat: Interior,flat, latex based paint. Q' \ Factory prime all surfaces (oven dry primer one mil minimum). All door frames to be painted. � � before proceeding if unsafe conditions are encountered. Protect existing construction during cutting and patching to prevent damage. Temporarily cover openings when not in (1) Moore:Moorcraft Super Spec Latex Flat#275. �jj \ � 2 S-W: ProMar 200Latex Flat B30W200. SCOTT MICHAEL 1 use. Patch with durable seams that are as invisible as possible. Inspect and test patched areas to demonstrate integrity of the installation. Do not cut structural members without � � NEVIN prior written approval of Architect and Structural Engineer. For patching provide materials whose installed performance will equal or surpass that of existing materials. For Wood Doors: (3) KWAL:218010 EnviroKote Zero VOC Interior Latex Flat MPI 144 * * ex osed surfaces, rovide or finish materials to visuall match existin ad'acent surfaces to the fullest extent ossible. Submit Product Data and door schedule. 2. Paint S stem-Ac lic Latex E Shell Enamel: Two finish coats over rimer with total d film thickness not less than 3.5 mils. P p Y 9 J p Y �' 9g- p ry 202985 Installation: Source limitations: Obtain flush wood doors through one source from a single manufacturer. a. Primer: �j Quality Standard: Comply with WDMA I.S.1A-04. (1) Moore:Moorcraft Super Spec Latex Enamel Undercoater and Primer Sealer#253. C� ���'� Comply with manufacturer's written instructions for installation. Anchor each product securely in place, accurately located and aligned. Clean exposed surfaces and protect �� �� Factory Finish: Provide factory finished doors. Comply with WDMA finish requirements. Finish:WDMA TR-6 catalyzed polyurethane. Staining:As selected from (2) S-W: PrepRite 200 Latex Wall Primer B28W200. from damage. If applicable, prepare surfaces for field finishing. manufacturer standard colors or custom color in accordance with he a roved sam le to match existin Facto finished doors to be installed 'ust rior to substantial 3/3/20 A Final Cleaninq: pp p g• ry 1 P (3) KWAL:118000 EnviroKote Interior Zero VOC Primer/Sealer completion. Doors with significant graining deviations from approved sample to be returned/replaced prior to installation. b. First and Second Coats: Clean each surface or item as follows before requesting inspection for certification of Substantial Completion: Examination: Examine doors before hanging. Reject doors with defects prior to hanging. Proceed with installation only after unsatisfactory conditions have been corrected. (1) Moore:Moorcraft Super Spec Latex Egg-Shell Enamel#274. Remove labels that are not permanent. Installation: Install doors per the manufacturers written instructions. Align all doors for uniform clearance at each edge. Restore factory finish before installation if fitting or (2) S-W: ProMar 200Latex Egg-Shell B20W200. Clean transparent materials, including mirrors. Remove excess glazing compounds. machining is required at project site.Adjust all doors to swing and operate freely. (3) KWAL:318010 EnviroKote Zero VOC Interior Latex Eggshell Enamel. Replace chipped or broken glass. Warranty: Provide full lifetime manufacturers warranty for Interior particle board core doors. 3. Paint System: Low-Odor Semi-Gloss Alkyd Enamel finish: Three coats with total dry film thickness not less than 2.5 mils. � � � • �� ' • � Clean exposed finishes to a dust-free condition, free of stains,films and foreign substances. Manufacturer: Marshfield Door Systems a. Primer: White, interior, latex-based primer. Leave concrete floors broom clean. (1) Moore:Moorcraft Super Spec Latex Enamel Undercoater and Primer Sealer#253. Vacuum carpeted surfaces and wax resilient flooring. ACC@SS DOOPS 811d Pall@IS: (2) S-W: PrepRite 200Latex Wall Primer B28W200. Architectural, Mechanical and Electrical Punchlist: (3) KWAL:118000 EnviroKote Interior Zero VOC Primer/Sealer � Submit Product Data. Paint to match adjacent surface. T T��� Provide Architect with a pre-punch list of items yet to be completed prior to request for inspection. Architect to schedule punch list based on completion of installation of all Steel Sheet: ASTM A 366 commercial-quality, cold-rolled steel sheet with baked-on, rust-inhibitive primer. b. First and Second Coats: Interior, Semi-Gloss, Low Odor, Alkyd Enamel. `� finishes and after final cleaning. Trimless, Flush Access Doors for Gypsum Board: Units consisting of frame, concealed edge trim, door, hardware, and complying with the following requirements: (1) Moore:Moorcraft Super Spec Alkyd Semi-Gloss Enamel#274. Closeout Submittals: Frame: 0.0598-inch thick steel sheet. (2) S-W: ProMar 200 Alkyd Semi-Gloss B34W200. V all�y Record Drawings: Maintain a set of Contract Drawings as Record Drawings. Mark to show installation that varies from the Work as originally shown. Door: 0.047-inch thick steel sheet. (3) KWAL:518010 EnviroKote Zero VOC Interior Latex Semi-Gloss Enamel. Operation and Maintenance Data: Organize data into 3-ring binders,with pocket folders for folded sheet information. Concealed, Gypsum Board Edge Trim: 0.0299-inch zinc-coated or galvanized-steel sheet with face flange formed to receive joint compound. � Hinge: Concealed spring pin or continuous type. c. 4. Paint System: Semi-Gloss, Water based, Epoxy Finish. Two finish coats over a primer. MediCU.� Closeout Procedures: Locks: Screwdriver-operated cam. a. Primer: latex-based interior primer applied at spreading rate recommended by the manufacture to achieve a total dry film thickness of not less than 1.2 Request Substantial Completion inspection once the following are complete: mils. Advise Owner of endin insurance chan eover re uirements. (1) KWAL:0880 ProFinish Latex Primer Sealer; �oW�o�. C enter P 9 9 q Door Hardware: b. First and second coats: Semi-gloss, water based epoxy applies at spreading rate recommended by the manufacture to achieve a total dry film thickness of Submit Record Drawings, Maintenance Manuals,Warranties and similar record information. Warranty: 5 year repair or replacement of defective components. Lifetime warranty for replacing sagging levers and cylinder housing. not less than 2.6 mils. Deliver spare parts, extra stock and similar items. Submit Hardware Schedule. For fire-rated openings, provide hardware tested and listed by UL or FM (NFPA 80). On panic exit devices, provide UL or FM label indicating (1) KWAL:3165 Accu-Guard Water Epoxy Polyamide Coating; low VOC. Complete startup testing of systems. "Fire Exit Hardware." All hardware shall be ADA compliant. B. Ferrous Substrates: Remove temporary facilities and controls. Door Hardware: As indicated in the Hardware Schedule on the Drawings. Non-removable hinge pins for exterior and public interior exposure. 1. Paint System: Two finish coats over primary. Complete final cleanup. Cylinders with 6-pin tumblers. Lead lined doors shall receive lead shielded hardware. a. Primer: Synthetic rust-inhibiting primer: . . Touch up, repair, replace and restore marred, exposed finishes. Finishes: Refer to A0.2 (1) Moore:Alkyd Metal Primer M06. Va i I S u m m it Obtain final ins ections from authorities havin urisdiction. Keying: Provide 4 change keys per lock, provide 6 masters. . p 91 (2) S-W: Kem Kromik Metal Primer B50N2/B50W1. Orthopaedics Obtain certificate of occupancy. (3) KWAL:9210 Accu-Pro White Alkyd Rust Inhibiting Metal Primer. Upon receipt of a request for final inspection, Architect will proceed with inspection and advise the Contractor of unfilled requirements. M@tal Fi"11'Yllllg afld SUppOPtS: b. First and Second Coats: Acrylic Latex. Arrange for each installer of equipment that requires operation and maintenance to provide instruction to Owner's personnel. Steel framing components for suspended and furred ceilings complying with ASTM C 645 and ASTM C 754. (1) Moore:Moorcraft Super Sped Latex House and Trim#170. Warranties: Wire Ties: ASTM A 641 (ASTM A 641 M), Class 1 zinc coating, soft temper, 0.062-inch thick. (2) S-W: A-100 Latex House and Trim Paint A82 Series. Submit written warranties to the Architect prior to the date certified for Substantial Completion. If the Architect's Certificate of Substantial Completion designates a Hangers: Wire, ASTM A 641 (ASTM A 641M), Class 1 zinc coating, soft temper, 0.162-inch diameter. (3) KWAL:8200 Accu-Guard Acrylic DTM Semi-Gloss Finish. US BaClk BUIICIIfIg commencement date for warranties other than the date of Substantial Completion for the Work, or as a designated portion of the Work, submit written warranties upon request Carrying Channels: Cold-rolled steel, 2 inches. SUlte ZO6 of the Architect. Furring Channels: 7/8-inch deep, cold-rolled channels. TOII@t ACC@SSOi"I@S: Steel framing for partitions complying with ASTM C 645. �OH SOUtII FrOClta e Road When the Contract Documents require the Contractor, or the Contractor and a subcontractor, supplier or manufacturer to execute a special warranty, prepare a written Submittals: Studs and Runners: In depth indicated and 0.0179-inch thick, unless otherwise indicated. g document that contains appropriate terms and identification, ready for execution by the required parties. Submit a draft to the Owner,through the Architect,for approval prior to Rigid Hat-Shaped Furring Channels: In depth indicated and 0.0179-inch thick, unless otherwise indicated. Submit: Product data for each toilet accessory item specified, including construction details relative to materials, dimensions, gages, profiles, mounting method,specified Vail Colorado 81657 final execution. options, and finishes. � Furring Brackets: Adjustable serrated-arm type fabricated from corrosion-resistant steel sheet 0.0329-inch thick. Schedule indicatin t es, uantities, sizes and installation locations b room for each toilet accesso item to be rovided for Pro'ect. Mountin hei ht to be verified At Final Completion compile(2)two copies of each required warranty properly executed by the Contractor, or by the Contractor, Subcontractor, Supplier or Manufacturer. Provide double 16 gauge studs at each door jamb; extend to structure above. Provide 20 gauge studs at 16" O.C. behind casework; provide 25 gauge studs at 16"O.C. g yp q � y � ry p � g g Organize the warranty documents into an orderly sequence based on each technical Specification Heading. elsewhere; unless UL assembly requires different gauge. with Owner prior to installation. Request inspection for certification of final acceptance and finally payment, once the following are complete: Where new partitions adjoin existing construction, the new finished face shall align with the existing finished face unless noted otherwise. Manufacturer: Bradley corp. or equal. Owner to approve substitution prior to shop drawing submittal. Provide No.4 satin finish. �� _ _ � � �e1 , � � Submit final payment request with releases of liens and supporting documentation. Products: Paper towel dispenser: surface mounted, No.250 Include insurance certificates. �nsulation: Sheet Title: Submit consent of suret to final a ment. Grab bars: 812 series. heavy duty 18 gauge grab bars; concealed with set screws; standard No.4 satin finish; 1-1/2 inches diameter by 36 inches long behind toilet; y p y Thermal Batt Fiberglas Insulation: ASTM C665 Type1 and ASTM E 136 unfaced;fill cavity full height of wall. Owens Corning or equal. 1-1/2 inches diameter by 42 inches long to side of toilet; and provide 18" by 1-1/2"vertical bar per ANSI requirements. Install grab bars to withstand a downward load of On completion of re-inspection, Architect will prepare a certificate of final acceptance. If the Work is incomplete, Architect will advise Contractor of the Work that is incomplete or at least 250 Ib., complying with ASTM F 446. obligations that have not yet been fulfilled. GIaZl11 : g Soap dispenser: surface mounted, No.6562. Submit Product Data and Samples. Comply with written instructions of glass product manufacturers; FGMAs"Glazing Manual"; and publications of AAMA, LSGA, and SIGMA. Toilet tissue dispenser: surface mounted twin roll; No. 5402. Selective Demolition: Warranty: 10 years. Hook: double prong, surface mounted, No. 9124; height not to exceed 54"aff. Provide on back side of toilet and exam and cast room doors. S P E C I F I CAT I O N S Unless otherwise indicated, demolished materials become Contractor's property. Comply with EPA regulations and disposal regulations of authorities having jurisdiction. Interior Windows and Door Lites: 1/4"Tempered,textured glass;Arch Deco Glass "Chalk Sticks". Conduct demolition without disrupting Owner's occupation of the building. Items indicated to be removed and salvaged remain the Owner's property. Remove, clean and pack or crate items to protect against damage. Identify contents of container and Gypsum Board Assemblies: End of Specifications deliver to Owner's designated storage area. Gypsum Wallboard: ASTM C 36, in thickness indicated,with manufacturer's standard edges. All light switches,telephone, electrical, data outlets, etc. indicated to be removed or relocated shall be completely removed. Patch and apply finish indicated. A cover plate will Regular Type, and Type X where required for fire-resistance-rated assemblies. Water resistant. not be acceptable. Moisture Resistant Non-Rated Board:ASTM C 630, in thickness indicated. Regular Type and Type X where required for fire-resistance-rated assemblies. PGI'f'Tllt SG't 3/3/2014 Submit schedule indicating proposed sequence of operations for selective demolition work to Owner's Representative for review prior to start of work. Include coordination for Accessories: shutoff, capping and continuation of utility services as required, together with details for dust and noise control protection. Accessories for Interior Installation: Cornerbead, edge trim, and control joints complying with ASTM C 1047,formed from steel sheet zinc coated by hot-dip process or rolled Sheet Number: Provide detailed sequence of demolition and removal work to ensure uninterrupted progress of Owner's on-site operations. Conduct demolition work in manner that will zinc.Apply appropriate acoustical and water resistant sealants at all penetrations and joints. minimize need for disruption of Owner's normal operations. Finishing Gypsum Board Assemblies: In accordance with GA-214; Level 4 finish, unless otherwise indicated; Level 1 finish for concealed areas, unless a higher level of finish Maintain and rotect existin utilities to remain in service before roceedin with demolition, rovidin b ass connections to other arts of the buildin Locate, identi shut is required for fire-resistance-rated assemblies; and Level 2 finish where panels form substrates for tile. p g p g p g yp p g' �' Extend gypsum board and studs to structure unless noted otherwise. Exterior walls, soffits, and existing walls to remain with orange peel texture to be skim coated to meet off, disconnect, and cap off utility services to be demolished. Protect remaining walls, ceilings,floors, and exposed finishes. Erect and maintain dustproof partitions. Cover and level 4 finish. All new corner beads for be square. o protect remaining furniture,furnishings, and equipment. Promptly patch and repair holes and damaged surfaces of building caused by demolition. Restore exposed finishes of � patched areas and extend finish restoration into remaining adjoining construction. Promptly remove demolished materials from Owner's property and legally dispose of them. ■ z � � � DPA Project: 14901.00.000 0 COPVRIGHT 20'I4-DAVIS PARTNERSHIP,P.C. ■� ■ ■ ■ ■■ ■ ■ � DOOR AND FRAME SCHEDULE ■ . ■ D00 R FRAM E � , 5/8" GYPSUM BOARD 5/8" GYPSUM BOARD ■ - SIZE HARDWARE . FIRE � � 2 METAL STUDS BACK TO BACK OPENING ROOM TYPE WD HGT THK TYPE RATING SET NO NOTES � � � � ,> , „ „ ■ ■ 202 WAITING D3 3 -0 7 -0 1 3 4 F1 -- H MEfAL HEAD TRACK � MEfAL CLOSURE TRACK 203 ADMIN WORK D1 3'-0" 7'-0" 1 3/4" F1 -- A HOLLOW METAL FRAME 204 EXAM D1 3'-6" 7'-0" 1 3/4" F1 -- � DAV I S _ , ,> , >, ,> 5 5 — — -- X—RAY 1 3 4 -N 205 D2 4 0 7 0 F2 C /' _ /' � a s � WELDED STEEL STUD ANCHORS � RECESSED 1/2" FOR STUD AND GYPSUM BOARD 206 CAST D 1 3'—6" 7'—0" 1 3/4" F 1 -- � PA RT N E R S H I P N � N � 208 EXAM D1 3'-0" 7'-0" 1 3/4" F1 -- � A RC H I T ECTS 209 EXAM D1 3'-0" 7'-0" 1 3/4" F1 -- C 210 EXAM D1 3'-0" 7'-0" 1 3/4" F1 -- C WOOD DOOR HOLLOW METAL FRAME 2301 Blake Street, Suite 100 2�2 P/PA D1 3'-0" 7'-0" 1 3�4" F3 -- C DenverlDenver, C080205 303.861.8555 213 ADMIN D1 3'-0" 7'-0" 1 3/4" F1 -- A WOOD DOOR 214 P�PA D1 3'-0" 7'-0" 1 3�4" F1 -- C vail10225 Main Street, UnitC101 Edwards, CO 81632 970.926.8960 215 EXAM D1 3'-0" 7'-0" 1 3/4" F1 -- C NEW PARTITIONS NEW PARTITIONS 217 EXAM D1 3'-0" 7'-0" 1 3�4" F1 -- C � � � � COORD. WITH COORD. WITH 218 EXAM D1 3'-0" 7'-0" 1 3/4" F1 -- C PARTITION SCHEDULE PARTITION SCHEDULE 21g NURSE D1 3'-0" 7'-0" 1 3�4" F1 -- F BEAUDIN GANZE CONSULTING ENGINEERS 220 COATS D1 3�-0�� 7�-0�� 1 3/4�� F1 -- C 222 CHAPEL PLACE, UNITAC-201 222 SERVER D1 3'-0" 7'-0" 1 3 4" F1 -- p P.O. BOX9650 � AVON, COLORADO 81620 224 TOILET D1 3'-0" 7'-0" 1 3/4" F1 -- B 970.949.6108 1 HOLLOW METAL HEAD 2 HOLLOW METAL JAMB 225 BREAK D1 3'-0" 7'-0" 1 3/4" F1 -- C ao.2 3" = i'—o" ,ao.2 3" = i'—o" 227 OFFICE D1 3'-0" 7'-0" 1 3/4" REUSE -- REUSE 228 OFFICE D1 3'-0" 7'-0" 1 3/4" REUSE -- REUSE 229 CONFERENCE D1 3'-0" 7'-0" 1 3/4" F1 -- A 5/8" TYPE X GYPSUM BOARD 5/8" GYP. BD. 230 CORRIDOR D1 3'-0" 7'-0" 1 3/4" F1 -- F LEAD LINING i ��ao ��N�NC HARDWARE NOTES HARDWARE GROUPS 2 METAL STUDS BACK TO BACK 2 METAL STUDS BACK TO BACK Group #A 3 HINGES 5BB1 4.5" US32D IV A TR RA ND50PD RHO MEf L CLOSURE ACK MEfAL CLOSURE T CK 1. ALL WELDED FRAMES WITHIN THE WORK AREA TO BE PAINTED. 1 OFFICE LOCKSET 626 SC 1 WALL BUMPER WS407CCV US32D IV /� _ j� , ' 2. HOLLOW METAL FRAMES TO MEET SDI (STEEL DOOR INSTITUTE) 3 DOOR SILENCERS SR64 X IV � � WELDED STEEL STUD ANCHORS, REQUIREMENTS, INCLUDING SDI-105-91 AND SDI-100-91 . >, RECESSED 1/2 FOR STUD AND GYP. BD. Group #B 3 HINGES 5BB1 4.5 26D IV N � LEAD LINING PER N � LEAD LINING PER 3. INTERIOR WOOD DOORS TO BE 5—PLY MARSHFIELD DOORS 1 PRIVACY LOCKSET ND40S RHO 10-025 626 SC L � PHYSICIST'S REPORT PHYSICIST'S REPORT DOORS TO BE FLUSH DESIGN, 1 -3/4" THICK, SEAMLESS FACE 1 WALL BUMPER WS407CCV US32D IV AND EDGE CONSTRUCTION. 3 DOOR SILENCERS SR64 X IV HOLLOW METAL FRAME HOLLOW MEI�AL FRAME 4. DOOR ASSEMBLIES IN INTERIOR PARTITIONS ARE 6" FROM Group #C 3 HINGES 5BB1 4.5" 26D IV FINISHED FACE OF ADJACENT PARTITION TO THE EDGE OF THE 1 PASSAGE LOCKSET ND10S RHO 626 SC LEAD LINED WOOD DOOR LEAD LINED WOOD DOOR DOOR LEAF UNLESS NOTED OTHERWISE. 1 WALL BUMPER WS407CCV US32D IV 3 DOOR SILENCERS SR64 X IV 5. HINGES AT ENTRY TO BE HEAVY DUTY. LOW USE DOORS NEW PARTITIONS NEW PARTITIONS CAN BE MEDIUM DUTY. PROVIDE BALL BEARING TYPE, Group #D 3 HINGES 5BB1 4.5" US32D IV COORD. WITH COORD. WITH 4-1/2"x4-1/2" 3 PER LEAF FOR DOORS 7'-0" HIGH 1 3 4" 1 STOREROOM LOCKSET ND80PD RHO 626 SC _ � ' � 1 WALL BUMPER WS407CCV US32D IV �' • � r��� 1►� PARTITION SCHEDULE PARTITION SCHEDULE AND LESS, 4 PER LEAF FOR DOORS OVER 8'-0" HIGH. 3 DOOR SILENCERS SR64 X IV HINGES TO BE BRUSHED CHROME, WiTH FLAT BUTTON TIPS � AND NON—REMOVABLE PINS AT EXTERIOR DOORS. Group #E 2 PIVOT HINGES 7230f-3/4—LL US32D IV OF C��O 1 PASSAGE SET WD10S RHO 626 SC � 6. ALL HARDWARE TO BE LEVER TYPE; ADA COMPLIANT. US32D IV �� O� 1 WALL BUMPER WS407CCV 3 LEAD LINED HOLLOW METAL HEAD 4 LEAD LINED HOLLOW METAL JAMB 1 INTERMEDIATE PIVOT HINGE 7230E-3/4—INT—LL US32D IV � SCOTT MICHAEL ao.2 s" = i'—o" ao.2 3" = i'—o" �� ALL HARDWARE TO HAVE US 32D, 26D, 626 OR 689 * NEVIN * FINISH. Group #F 3 HINGES 5BB12800 SERIES US32D IV 202985 � 1 KEYPAD LOCKSET ALARM LOCK DL 2700 626 LO � 1 WALL BUMPER WS407CCV US32D IV �� �,�� LE(a'EN� 3 DOOR SILENCERS SR64 X US32D IV �,�� � i 1 /14/20 �D A� 5/8" TYPE 'X' GYP. BD. 5/8" TYPE 'X' GYP. BD. Group #G 3 HINGES (HEAVY WEIGHT) 35BB1 H3 4.5" 6262D L� � AL — ALUMINUM IV — IVES 1 KEYPAD LOCKSET ALARM LOCK DL 2700 US32D IV GL — GLASS LC — LCN 3 DOOR SILENCERS WS407CCV US32D VD CONTINUOUS DOUBLE STRUCTURAL CONTINUOUS DOUBLE STRUCTURAL HM — HOLLOW METAL LO — LOCKNETICS 1 ELECTRIC STRIKE 6210 US32D LCN � • "• � • '�� • � STEEL STUDS AT EACH JAMB, SILL STEEL STUDS AT EACH JAMB, SILL MIN — MINUTE VD — VON DUPRIN 2 WALL ACTUATOR 8310-856T US32D IV AND HEAD; WELD TOGEfHER AND HEAD; WELD TOGETHER PT — PAINT PE — PEMKO 1 WALL BUMPER WS407CCV US32D LCN AND EXTEND TO STRUCTURE AND EXTEND TO STRUCTURE STL — STEEL RO — ROCKWOOD 1 AUTO OPERATOR 9531 SHIM AS REQUIRED SHIM AS REQUIRED T — TEMPERED RX — RIXSON 8., �.. SC — SCHLAGE Vail ----- �IN _____________ ^� _____- . ___-__-_ _______ ______ _____________ __-___-_ __ N ��N N �,N LEAD LINING PER � L J PHYSICIST'S REPORT Med�cal HOLLOW METAL FRAME HOLLOW METAL FRAME VARIES VARIES VARIES 2 2 2 2 VARIES N � 3-6" N Center 1/2 METAL STOP 1/2 METAL STOP 1/4" TEMPERED GLASS 1/4" TEMPERED GLASS/LEAD LINED GLASS 1 3 PER PHYSICIST'S REPORT A0.2 A0.2 2 4 NEW PARTITIONS NEW PARTITIONS o 0 o Ao.2 0 ,40.2 � Va i I S u m m i t COORD. WITH COORD. WITH ;� ;� ;� 2 ;� 4 ;� PARTITION SCHEDULE PARTITION SCHEDULE Ao.2 Ao.2 Orthopaedics 5 HOLLOW MTL. WINDOW JAMB SILL HEAD 5 LEAD LINED WINDOW JAMB SILL HEAD A0.2 3" = 1'-0" A0.2 3" = 1'-0" US Bank Building D 1 D2 D3 F 1 F2 Suite 206 WOOD DOOR WOOD DOOR WOOD DOOR INTERIOR H.M. FRAME INTERIOR H.M. FRAME 108 South Frontage Road NON—RATED LEAD—LINED W�TH LITE NON—RATED LEAD—LINED VaII, COIOi"aCIO 81657 NON—RATED NON—RATED NON—RATED � - - i � � ��. •� Sheet Title: DOOR HARDWARE, FRAMES, SCHEDULES AN D D ETAI LS Permit Set 1/14/2014 Sheet Number: o ■ 0 N � � 3 � DPA Project: 13917.00.000 0 COPVRIGHT 2013-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ FINISH KEY INTERIOR FINISHES GENERAL NOTES �� � � � � � � � , 1 . ALL FINISH SAMPLES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR TO VERIFY AVAILABILITY AND STOCK ■ . ■ . - FLOOR COVERINGS CEILING FINISH OF MATERIALS AND ALLOW ENOUGH TIME TO RECEIVED GOODS FOR INSTALLATION TO OCCUR AT REQUIRED TIMES. ■ ■ ■ ■■ CPT1 — CARPET, 12' BROADLOOM ACT1 — 2' X 4' ACOUSTICAL CEILING TILE 2• CONTRACTOR SHALL PATCH AND REPAIR EXISITNG WALLS, FLOORS AND CEILINGS AS REQUIRED FOLLOWING DEMOLITION OF EXISTING PARTITIONS MANUF: SHAW MANUF: ARMSTRONG AND EXISTING FINISHES. PATCHED AREAS SHALL BE INVISIBLE. STYLE: #5A036 KENDARI STYLE: CORTEGA SECOND LOOK, DAV I COLOR: #36500 CHOCOLATE FLOWER ANGLED TEGULAR, 9/16" GRID, #2776 3. WHERE NEW PARTITIONS ADJOIN EXISTING BUILDING PARTITIONS, THE NEW PARTITION FINISH SHALL ALIGN WITH EXISTING FINISH. FINISHED S COLOR: WHITE SURFACES OF NEW WORK MEETING EXISTING CONSTRUCTION OF SIMILAR MATERIALS IN THE SAME PLANE SHALL BE FLUSH WITH NO VISIBLE SV1 — SHEET VINYL JOINT SHOWING. WHENEVER EXISTING FINISH MATERIAL AND/ OR SURFACES MUST BE CUT OR OPENED: REPAIR AND RESTORE SO THAT THE PARTN E RSH I P MANUF: SHAW ACT2 — 2' X 2' ACOUSTICAL CEILING TILE FINISHED PATCH IS INVISIBLE AND MATCHES ADJOINING ORIGINAL WORK IN EVERY WAY. STYLE: 0002V NATURELIFE: WOOD MANUF: ARMSTRONG COLOR: 05301 TRAD�TIONAL CHERRY A R C H I T E C T S STYLE: CORTEGA TILE, BEVELED TEGULAR, 4. WHERE CONSTRUCTION HAS DISRUPTED THE EXISTING WALLS, FLOORS, CEILINGS, ETC. THE FOLLOWING SHALL OCCUR: 9/16" GRID, #2195 T1 — 12" X 12" PORCELAIN FLOOR TILE COLOR: WHITE A. WHERE WALLS HAVE BEEN REPAIRED AND PATCHED, THE ENTIRE WALL IS TO BE REPAINTED, SO THAT THE PATCH IS INVISIBLE Denverl2301 Blake Street, Suite 100 MANUF: DALTILE ACROSS THE ENTIRE WALL SURFACE. Denver, CO 80205 303.861.8555 COLOR: SAND P505 OPEN — OPEN TO STRUCTURE B. WHERE WALL BASE HAS BEEN REPAIRED AND PATCHED, NEW BASE TO MATCH EXISTING SHALL INFILL 2'-6" IN EITHER DIRECTION VaiI10225 Main Street, Unit C101 GYP — GYPSUM BOARD OF THE PATCH AND REPAIR (5'-0" LINEAR FEET TOTAL) TO MAKE THE PATCH INVISIBLE. Edwards, CO 81632 970.926.8960 WALL BASE C. WHERE FLOOR HAS BEEN REPAIRED AND PATCHED, NEW CARPET, VCT, VINYL SEAMLESS FLOORING AND/OR TILE TO MATCH EXISTING SHALL INFILL 3'-0" IN ANY DIRECTION OF THE PATCH AND REPAIR (9'-0" SQUARE FEET TOTAL) TO MAKE THE PATCH �� � , � � WALL FINISHES INVISIBLE. RB1 — RUBBER BASE, 4" COVE D. WHERE CEILING HAS BEEN REPAIRED AND PATCHED, NEW CEILING GRID, ACOUSTICAL CEILING TILE, AND/OR GYPSUM BOARD TO MANUF: JOHNSONITE CR — MAPLE CHAIR RAIL, � �� > >� BEAUDIN GANZE CONSULTING ENGINEERS COLOR: 283 TOAST „ „ MATCH EXISTING SHALL INFILL 2 -0 IN ANY DIRECTION OF THE PATCH AND REPAIR (4 —0 SQUARE FEET TOTAL) TO MAKE THE 222 CHAPEL PLACE, UNITAC-201 1 x4 WITH EASED EDGE PATCH INVISIBLE. IF CEILING GRID AND/ OR TILES ARE TO BE REPLACED, THEY SHALL BE REPLACED IN WHOLE INCREMENTS, SO P.O. BOX 9650 TB1 — 6" X 12" TILE COVE BASE „ „ AS TO MAKE THE PATCH INVISIBLE. WHERE GYPSUM BOARD CEILINGS ARE PATCHED AND REPAIRED, THE ENTIRE CEILING IS TO AVON, COLORADO 81620 MANUF: DALTILE WT1 — 4 X 4 CERAMIC WALL TILE BE REPAINTED, SO THAT THE PATCH IS INVISIBLE ACROSS THE ENTIRE CEILING PLANE. 970.949.6108 COLOR: SAND P505 MANUF: DAHL COLOR: ARTISAN BROWN 0144; SEMI—GLOSS 5. ALL VERTICAL DIMENSIONS SHOWN TO FLOOR ARE TO BE FINISHED FLOOR, UNLESS NOTED OTHERWISE. WHERE FINISH IS TO BE CARPET, VERTICAL DIMENSION IS TO SLAB. T2 — 2" X 4" BULLNOSE TRIM TILE WALL FINISH MANUF: DALTILE 6• WHERE EXISTING WORK IS TO REMAIN AND BE REPAINTED, PATCH AND REPAIR AS REQUIRED SO THAT ALL PATCHED AREAS ARE INVISIBLE. COLOR: ARTISAN BROWN 0144; SEMI—GLOSS NEW WORK THAT ADJOINS EXISTING SURFACES SHALL BE FLUSH, TRUE, PLUMB AND/OR IN SAME PLANE AS THE EXISTING WORK AND FINISHED PT1 — PAINT TO MATCH TO BLEND AND MATCH IN TEXTURE AND FINISH WITH ADJACENT SURFACES. FLOAT PATCHES AND JOINTS A MINIMUM OF 24" WIDE TO BLEND MANUF: IC� WT2 — 1 " X 1 " MOSAIC ACCENT TILE AND FINISH INVISIBLY. COLOR: 640 IVORY SAMPLER MANUF: DALTILE # ALTERNATE COLORS: �• CONTRACTOR SHALL TAKE CARE TO PROTECT ALL NEWLY INSTALLED MATERIALS AND FINISHES UNTIL WORK IS FORMALLY ACCEPTED BY THE M1 —WATERFALL D169 ARCHITECT AND OWNER. DAMAGED ITEMS OR FINISHES ARE TO BE REPAIRED OR REPLACED, AS REQUIRED BY THE ARCHITECT. PT2 — PAINT TO MATCH M2—GOLDEN GRANITE D136 MANUF: ICI M3—UPTOWN TAUPE SPECKLE D202 8. ALL FLOOR TRANSITIONS TO OCCUR AT THE CENTERLINE OF THE DOOR UNLESS OTHERWISE NOTED. FLOOR TRANSITION STRIPS SHALL BE COLOR: #530 CAMELCOAT SUBMITTED TO ARCHITECT FOR COLOR SELECTION. FLOOR TRANSITIONS REQUIRED AT ALL CHANGES IN FLOOR MATERIALS. PT3 — PAINT TO MATCH 9. HOLLOW METAL FRAMES TO BE PAINTED PT5. MANUF: ICI COLOR: #1212 MOUNTAIN CREEK 10. ALL WOOD DOORS TO BE WHITE MAPLE, PLAIN SLICED WITH CLEAR FINISH. LITES TO HAVE WOOD STOPS TO MATCH DOOR. PT4 — PAINT TO MATCH 11 . ALL PAINT TO BE EG SHELL OR SATN SHEEN, UNLESS NOTED OTHERWISE. MANUF: ICI COLOR: #308 PADRE ISLAND � 2• PROVIDE CHAIR RAIL (CR) AT EXAMS, CAST AND WAITING ROOM AS SHOWN DASHED ON A2.0. PT5 — HOLLOW METAL FRAMES MANUF: IC� COLOR: #361 COACH HOUSE BROWN ROOM FINISH SCHEDULE - : - .� .t'�� 1'.R.� CASEWORK FINISHES N0. NAME FLOOR BASE WALL CEILING REMARKS PL1 — PLASTIC LAMINATE — ALL VERTICALS � pF C4�0 MANUF: PIONITE � NORTH EAST SOUTH WEST � � � COLOR: #DWC421 OILED CHERRY 200 CORRIDOR --- ME --- --- ME ME --- � SCOTT MICHAEL �O T2 T2 201 RECEPTION CPT1 RB1 PT2 PT2 PT4 PT2 ACT2 � � PL2 — PLASTIC LAMINATE — COUNTERTOPS AND SPLASHES I I I �, * NEVIN * MANUF: FORMICA M1 M2M M1M2 M3 M1M2 202 � WAITING CPT1 R61 PT2 � PT2 � PT3 PT3 ACT2 �,� 202985 COLOR: #3526-58 TRAVERTINE, MATTE SMOOTH FINISH M2M3M1M2M3 M1 M2M3 203 ADMIN WORK I CPT1 RB1 PT1 PT1 I PT1 PT1 ACT1 � <�� ���� 204 I EXAM CPT1 RB1 PT2 PT2 PT4 PT2 ACT1 \, � 205 � X—RAY � SV1 RB1 PT2 � PT2 PT2 PT2 ACT1 PT4 BOTH SIDES OF CONTROL WALL �� p`� ,�, ,�, 3/3/20'I 206 CAST SV1 RB1 PT2 PT2 � PT2 PT2 ACT1 207 HALL CPT1 PB1 PT1 PT1 PT1 PT1 ACT2 208 EXAM I CPT1 RB1 PT2 PT2 � PT2 PT3 ACT1 2pg � EXAM CPT1 RB1 PT2 IPT2 PT4 PT2 ACT1 ' • - � • u. •� 210 I EXAM CPT1 RB1 PT2 IPT2 PT3 PT2 ACT1 211 NURSE CPT1 RB1 PT1 � PT1 PT1 PT1 ACT1 212 I P/PA I CPT1 RB1 PT1 I PT1 I PT1 PT1 ACT1 • 213 I ADMIN CPT1 RB1 PT1 I PT1 PT1 PT1 ACT1 ��1� 214 P/PA CPT1 RB1 PT1 PT1 PT1 PT1 ACT1 s� 215 I EXAM I CPT1 RB1 PT2 I PT4 I PT2 PT2 ACT1 ��llley 216 I HALL I CPT1 RB1 PT1 IPT1 IPT1 PT1 ACT2 � 217 EXAM CPT1 RB1 PT4 PT2 PT2 PT2 ACT1 Medical 218 EXAM CPT1 RB1 PT3 PT2 � PT2 PT2 ACT1 219 I NURSE CPT1 RB1 PT1 I PT1 PT1 PT1 ACT1 Center 220 COATS CPT1 RB1 PT1 PT1 PT1 PT1 ACT1 221 I HALL I CPT1 RB1 PT1 � PT1 PT1 PT1 ACT1 222 I SERVER SV1 RB1 PT1 � PT1 PT1 PT1 OPEN 223 HALL CPT1 R61 PT1 PT1 PT1 PT1 ACT1 Va i I S u m m it 224 TOILET T1 TB1 T2 WT1 WT2 PT3 , T2 WT1 WT2 PT3 PT3 PT3 GYP—PT1 SEMI GLOSS PAINT 225 BREAK SV1 RB1 PT2 PT4 PT2 PT4 ACT1 Orthopaedics 226 STORAGE CPT1 RB1 PT1 PT1 � PT1 PT1 ACT1 227 I OFFICE CPT1 RB1 PT1 PT1 PT1 PT1 ACT1 228 OFFICE I CPT1 RB1 PT1 � PT1 I PT1 PT1 ACT1 US Bank Building 229 II CONFERENCE I CPT1 RB1 PT2 I PT2 I PT3 PT2 ACT1 Suite 206 230 I CORRIDOR --- ME --- I --- --- ME --- � I � I 108 South Frontage Road � � � � Vail, Colorado 81657 �- � . ��. .� Sheet Title: INTERIOR FINISHES AND SCHEDULE Permit Set 3/3/2014 Sheet Number: 0 o ■ N T N � � DPA Project: 14901.00.000 0 COPVRIGHT 2014-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ ■■ ■ ■ � ■ ■ ■ ■ ■ ■ ■ � � � ■ ■ ■ ■■ DAV I S PARTNERSHIP ARCH ITECTS Denverl2301 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 Vail 0225 Main Street, Unit C101 Edwards, CO 81632 970.926.8960 •� . � BEAUDIN GANZE CONSULTING ENGINEERS 222 CHAPEL PLACE, UNIT AC-201 P.O. BOX 9650 AVON, COLORADO 81620 970.949.6108 42 (x.2)=8.4" STAIR WIDTH REQUIRED I � VVMC HUMAN RES URCES � �� �� � �36" PROVIDED , 669 SF � �F O�; , 42 (x.3)=12.6 DOOR WIDTH REQUIRED � �� ��� ` 34" PROVIDED 7 OCC �Q. � 'Qya � o r � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � _ � SCOTTMICHAEL � EXISTING ELEVATOR PROVIDES ACCESS FROM PARKING c � SP * NEVIN * GARAGE AND ACCESSIBLE ROUTE TO TENANT SPACE � � 202985 � � % ���� � �' � � EXIT LIGHTING � � � ' � _ � � � _ VVMC QUALITY m ExiT si�N 3/3/20 � A�� � �� 337 SF �_, 1 �' 16��, FA FIRE ALARM SWITCH � �r� � _�� �_ y _:,� 4 OCCUPANTS 12 FS FIRE ALARM STROBE � '� BUI�LDING CIRCULA`T.lON FP FIRE ALARM PANEL ' � - � � • u .� • � 1 ' � ' � __ ---- 655 SF -;-_ - FEC FIRE EXTINGUISHER CABINET � � � FS FHC FIRE HOSE CABINET �,;;; � 7 OCCUP��TS � j � � VSO _ 23 SP STAND PIPE • -� � o Vall � 3 306 SF s� SMOKE DETECTOR � �_ F��" 34 OCCUPANTS -� - - �alle , _ _ __ , 2 y � � � � � SD FS SD ,--° . � � Med�cal I _ _ 100' COMMON PATH OF EGRESS TRAVEL _ � i � ( M E D EQ U I P ; � � ALLOWED IN FULLY SPRINKLED BUILDING -- —���' r � U ' 2OO SF Center � FS � � 2 OCCUPANTS 1 ,,1`� - 1 i ��'� � ��,, - ' � ' ��� � �� � �� � Vail Summit i 85' ' ' -- -�� i SD Ortho aedics � -- - --- --- -- � � — � ------------ � � r�� � � -. �-------- ------� i 1 j I � � US Bank Building , � � 1 �, � � ' ; j � �2 `� Suite 206 �� WMC IT � � � � � ----- ------ � �__;_ � ' � � � � � I 2,343 S F 108 South Frontage Road 1 1 SDv 24 OCCUPANTS Vail, Colorado 81657 . ::� � w � �� � �� _ FEC 17 � � n � ,�� � �� � � - - � • u. � � 1 --�--, �� 5 � � �--1��� -'� VSO FOUNDATION � Sheet Title: � � 436 SF i Fs � 5 OCCUPANTS �m FA � � � ��"�'�""`�, `� �� ,�'�'"� ��4� �� � L I F E SAF ETY PLAN � � � ! � � t_ p US BANK AND NOTES � � I � , � �P I I I SECOND FLOOR ' � � Permit Set 3/3/2014 �.. � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � .� SheetNumber: 41(x.3)=12.3" DOOR WIDTH REQUIRED 41 (x.2)=8.2" STAIR WIDTH REQUIRED 34" PROVIDED 36" PROVIDED � , SECOND FLOOR LIFE SAFETY PLAN � T = R2.0 " ' " ' ' � 1 /8 = 1 -0 0 4 8 DPA Project: 14901.00.000 s COPYRIGHT 20�4-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ � _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � ■■ ■ ■ � � - � � ■ ■ ■ � —► =T ■ ■ � r!���� �� � � � ► 1 ■ � � � � L'��1JJI �"/I I I I � � I I I I I I II II ' ■ ■ � ■� i i i i ii i ► O UP � ii iiii ii I � � , � � � � � � � � � - � � � � � � � - DAVIS � ii ,� iiiiii _ _ i � � ��� , I � � i �� � � i i i � � � � �-��� PARTNERSHIP _� _`__ _______��. _ � �, � �- � i � i i i i N r T � I i ARCH ITECTS � _ � ii � � � ii � i � � �� � � i � , � I 3 � � � � � � i ' - Denver 2301 Blake Street, Suite 100 � O = _ �J I I / I I / I IDenver, CO 80205 303.861.8555 t I / � � � / � � � / �I � � ' 0225 Main Street, Unit C101 j� �\ I I /� II I I // II I I � Vail lEdwards, CO 81632 970.926.8960 I �\ �, i i � i i i i � i i i i � �.\ _ _. � � �- - - �- - � u � - - - - - - - - - - - - - - - u ' � .� ,. � I � � - - - - - - - - - - �, !� - - - - - - - - - - - - - - - �t , � II � � � � c II I ' BEAUDIN GANZE CONSULTING ENGINEERS /;/ I I /� � 2 lO5 222 CHAPEL PLACE, UNIT AG201 I I I / O ' P.O. BOX 9650 I I � I AVON, COLORADO 81620 II I / --� 970.949.6108 DEMO LEGEND ______________ ___________" � � _ _ � �_______________��_______� � � r� � , � , � � � � „ I I � ' ii i � `� i � ' � `� ii ME� � �' INDICATES EXISTING WALLS OR � I I I � I � � � �� �J PARTITIONS TO REMAIN I � I ���� I � �� � � j iiJ i' II � � � I � II � j � � � � � �� / II 0 � � INDICATES EXISTING WALLS OR / ��\ � u \ � I I � _ _ I � I � � � � - - � �� , PARTITIONS TO BE REMOVED I � �,�,� ��-------- � � � I � � � � ��--� I � / `�°�' \ I I i I � ' :_. i � JAN ITO R j;+ INDICATES EXISTING � I � DOORS TO REMAIN � ________-��. I � � � �� ' � � ., � i� � -� � �� - - - - - -j� j � ��� �` ' � � I �� � � � l�� � I � � � �i �� �J I � — ��� ��� II � � � II � I I �� 0 � � INDICATES EXISTING �_ � � v II � � � � II I � I i �OMEN � DOORS TO BE REMOVED I � I r � � �� i i �� �J � I � I I � I °� I I II II II � I I I � � � � L - - - - - - - - - JJ � � �- - - - - - - - - - - � � I I I I I � � _ ��------ — � i I I I I I � � �� �' - ; - .� �. - � DEMO KEYNOTES � � � r � ' ' � � �� � ' �� i � � a�� �� ; � � �__� _ _ ► i °� °�� �� � i i i i i i i � � - - - - - - � ��i�` ' � �,�� ��� ���a I - - - - - - - - - - - - �L - - - - - - - - L � JL - - - - - - - - - - � I � I � II � � \\�/ ' � SCOTTMICHAEL � 1O NO WORK IN THIS AREA. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - T - - � I i � �� �� � I I * NEVIN * 2 SALVAGE CROWN MOLDING AND BASE FOR REUSE IN RECONFIGURED I I I � � I \� -� I � � 202985 � � �� �� 0 �oBBY aN� HA��waY. � j i I I j j � � TELE ELEC ELEC ' � , 3 CASEWORK TO BE REMOVED. I II I � � I � �� A� 0 � �-� i i i i i i i � � 3/3/20 O4 COORDINATE WALL DEMOLITION WITH NEW CONSTRUCTION PLAN. I I � � I I � � I I � � I I � O5 COORDINATE FINISH DEMOLITION WITH NEW CONSTRUCTION PLAN. � � I i i I I � f I ' � - � � • r� . • � � � � --. -- \ � _ _ � I � L - - - - - - - - - - - - 1� - - - - - - - - - - - - I � I L - - - - - - - - 4- - - - - - - - - - - - - - - �_ I II � � I • � , � Vall � � � � �' Valle , � y � � - - � . , Med�cal � _ _ _ I �� � - - -�—� - - - — _ �- - - �. Il I � � � �� � �t rt�-� �� DEMO NOTES , � _ _ _ _ _ _ _ L _ _ _ _ � � � �� , , ; Center � i � - - - - - - -� �� ii , , � �,� H 3 I �, II I I � 0 � I�I I I '�' 1. EXISTING FLOORING, BASE, CABINETS, CEILING, LIGHTS, DIFFUSERS, � ' � � DEVICES AND WINDOW TREATMENTS TO BE REMOVED IN THEIR ENTIRETY. I �I� I _% Vail Summit 2. WINDOW SILLS TO BE PROTECTED DURING CONSTRUCTION. I � �I 5 � Orthopaedics i � ' �� ' / I US Bank Building � - - - I :_ —. � — — — � Suite 206 I - T _ _ _- _ _ _T _ _ _ ,., .-: T .. . _ _ _ _ _ -- _ _ __ _ _ � — — — �^' , I 108 South Frontage Road � � �I Vail, Colorado 81657 � � � ��\ ._�- '"� � �1 I � - - � . ��. . � I � ii I I Sheet Title: � i i � ��� � 1 I � � ---– _ -- � � I I I � , _� � _ , ❑ I � DEMOLITION � PLAN AND NOTES � — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � Permit Set 3/3/2014 Sheet Number: o , DEMOLITION PLAN . � D2.0 1 /4" = 1 '-0" 0 2' 4' � � � DPA Project: 14901.00.000 s COPYRIGHT 20�4-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ ■■ ■ ■ � ■ ■ ■ ■ ■ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ � ■ � � � � � ; _ , PLAN LEGEND - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - � ■ ■ ■ ■■ I '_ 3 " � � 14 6/ I I - INDICATES EXISTING WALLS OR I ADMIN WORK 203 4'/a" ' I V 203 , DA I S PARTITIONS TO REMAIN I � O o I' � PARTNERSHIP I , „ � � � � INDICATES NEW WALLS � ° � � � -�o Z ARCH ITECTS � WAITING A7.0 2g I I - � � �� 202 I� .�, _ U I N D I CATES EX I STI N G I __ � � �N 2C 202 _ - ' Denver I2301 Blake Street, suite �o0 DOORS TO REMAIN i,'� » , 3 „ , , » 2'-��" , „ � � 0 Denver, CO 80205 303.861.8555 / I � � 0 �2-1Y 4-4/ 5-9" 4'-�" 2-2 3-0 '-11" '"' ' Vail 0225 Main Street, Unit C101 -L_ �-- � 4/» 4/�� 4/�� IEdwards, CO 81632 970.926.8960 I �`/�CR _ � OD A7.0 ' INDICATES NEW DOORS %:-�� i � -' •' � � ' � ;'';�'� / 11,_$�,° � � 5, �» — OC � � � 1 -2/ - - a BEAUDIN GANZE CONSULTING ENGINEERS � COFFEE CO `" ' 222 CHAPEL PLACE, UNIT AC-201 � �� 3-9 _ _ - - - - - i i ��� �' � � � ----� � � � CORRIDOR P.O. BOX 9650 / ' N � � UCREF � �% � '� I � � -�, _ _ _ _ _ _ � �- _ ��� � AVON, COLORADO 81620 // i I `_ ; � ;� � J �' 970.949_6108 /= � - / / ^ � 6A � � --- � � GENERAL NOTES � _ _ _ _ _ _ _ _ � o A�.o , ;; � i� p � � r�� � � I � �� �'-�v o � 6� a�.o I a�.o �B ���.-;��' � � � �- —' � � \1 1 . ALL FURNITURE AND EQUIPMENT BY OWNER. ��� � — - - - - - - - - 3'-0" CAST � ri i� � -03 2. ALL PARTITIONS TO HAVE 3 5/8" STUDS UNLESS I � ExAM 4 ❑ X-RAY �a" ❑ 4 2os °' ° ,�`� � 2oa 205 � 15 � � � � 1 � A7.0 NOTED OTHERWISE. � � A�.o »-� � 4/„ �o-sYa„ 4��� � 4,_�y, � , ��' ; '',. , „� � � � . , „ �� =�Y" �c 2 -o M E�I ,',`, I 4C _, 4��� c� � � 4/» RECEPTION 4%" � � \���_ - 1'-6" 1'-6" � 0 201 � 1.__ ' KEYNOTES � — - - 204 � 205 206 � N ^ 0 J , I �� I O NO WORK IN THIS AREA. I 5 - -- � N � �� � ,' �--i-'� �� � N �r- ;.«<�, 4 � � FIRE EQUIPMENT CABINET; RE: 14�A8.0. � ; � � 4' o'�' I I � Ha�� `° _ � � �� �� zo� � � o J,A��I I O3 ALIGN FINISHED FACES OF GYPSUM BOARD. I � 1 1 D a�.o _ _ _ _ _ _ ' �� � � 5 , ,, � NURSE - - - - - � r - - - - - - - - - - - - ; � ° � O MINIMIZE FRAMING AS POSSIBLE AT ALL COLUMNS. I ^ r� 2„ 210 cR cR 209 208 c� � 217 EXAM � � � t � `== i �I � j � � � � d- 2i� 17A � 1, �/ I=��' �'---' ' 'I 1'-g" � � 1'-g° 1'-g" � � �o � O O CENTER FRAMING ON CENTER OF MULLION. � � � � I A� o �, � WOMEN I 5 4%" EXAM I I4 a�� E2osM 4%" E2osM 4%" � 4$„ I � � _-- I 9'-0" 212 2io 9,-8" 9'-8" 9'-8" 4�-�" 10'-p" � � I � '`,; : .� �. - 1►� I , N I I I O I � I 1 i� � � � �� � �� , �v � � A7.0 � I � �R- - - - - - - - - - � � - Q� C�� \�� �� 0 � � � HA �� A7.0 � LL � 4 � 8 D A7.0 21 s Q- � I _ 12D A7.0 .� � I I 9C � I � ° , ' ,` O I `� P PA 10C � I I I - - — — � � SCOTT MICHAEL � _i 212 12C � I I � I — — — — � � � * NEVIN * �, ��� - � i - - - - - - - - - - - - 218 � - � � � 202985 - I - - 18A _ _ _ _ _ _ _ _ � EXAM i -- � '� O � � � I � - - - � � � � � �—� � 3 �� o � � °' V _� � 218 _ � � �� �� �� � � � 3-5/ �� 4%" I A7.0 � � ���a� �� A��� o rn 5'-11Y j 5'-4" 11'-6" - -= 9,_9},,, 2,_�" i � ( ' ._ s' 3/3/20 � - - - - -— —- - "' -- I -135� _ _ --�4�° � _ _ _ _ _ _ _ _ — _ �4�°° � 215 °� i i I � TELE ELE � 4 _ i i _- �—_ � � ,$„ - �� � �-� � � 4-9%" 4� 4'-9Y" � � I � I � � � � � � � �� _ _ �.o - � . . . , � �- . _� � _�I � � 5A � � � �R- - - - - - - - - -� �� ,� � � �� _ I i i i i � _ ��, I� I _ � � �,, � - � I � � � � , � I � � - � 14A O l/� - � _ i � I _ � , � ; i' � , � � ,� , � , � � - '�' I � �: , �� EXAM �_ - t. � , � �. 4 � / , -- � � � , ��' � � � 215 - - - - - - - � � • � � � 0 _ _. I � � 220 i ' � , � ,,�-� 13A � � P PA4D A7.0 214 � C0� S i, � � = Vall � - r — �' � -�! � 3 � � � �,4 �R_ _ _ _ _ _ _ _ _ ' ° � � � _ ,,' �� _ � � 11 � , � -- Va ey �- 7.0 13A ' � I 19A NURSE M��iC�l� `�,,,� _ 21 s ADMIN 224 HALL 'o � CORRI� R I 213 -� O 221 �- A�.� 21 g � Center � " ^ ^ PANEL FEC ' I � -_ 4$�, �_ ' f 3 I /TOILET \�24 4-6� 5�-9�� 229 224 230 I I -� 24� � SERVER � \ � �, HALL 2 2 2 222 "' ' V a i l S u m m i t I � 24D A7.0� 24B � � 223 - � w =_---, D�h� aedics _ � OPEN OFFICE I � L _ — � � i/ � � 22s �,.� I 24C ,- ` STORAGE O � � g � _ `� US Bank Building � � ° � Suite 206 N � � ^ _ ' __� 108 South Frontage Road � Vail, Colorado 81657 � „ _ 4% _L� �.r � r � !,;�� �` ,'�p» 4'-6%" 5,_g„ � 227 � 228 � ; � � N . 7�" '`�- �' 4'/s" - � - � . i�. . � ',,.-, STORAGE � � ���� BREAK z26 � ��� � Sheet Title: i � � 225 �' � � � �/J _, � ,�225 OFFICE OFFICE � �� � �z� ��$ � ���� N E W -�fi � �,�� ��, I ���-� ` � � � �-� � � �� ' � ` �� CONSTRUCTION PLAN 15-9%" � � 5'-9" � � '��� � \ � . � �' ��� I LEGENDS AND NOTES ,,� , � ��� � � � � ❑ . � 1. � ��� � _ � � - ' Permit Set 3/3/2014 � ' Sheet Number: � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � o � NEW CONSTRUCTION PLAN • N � A2.0 1 /4" = 1 '-0" 0 2' 4' � DPA Project: 14901.00.000 s COPYRIGHT 20�4-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ BORROWED LITE IN PAINTED HOLLOW INCANDESCENT PENDANT BORROWED LITE IN PAINTED HOLLOW ■■ . ■ - 9'-11" 4�-58�� METAL FRAME; RE 5 A0.2 8" 1'-6" 5'-10" 1'-6" 2'-0" 1'-6" 8�� � RE: ELECTRICAL METAL FRAME; RE 5/A0.2 ■ . ■ ■ , o PL2 TRANSACTION TOP W/ , OPEN ■ . ■ . - VAIL SUMMIT � MAPLE BULLNOSE / TO � ORTHOPAEDICS � `� \ i % i SIGNAGE � � OPEN EDGE: W1 FINISH HALL � � 0 0 ��;�� TO WAITING PL2 COUNTER W� MAPLE '� PL2 COUNTE W� MAPLE J E E J USB 3'-0" 4'-6%" � � PUSH � BULLNOSE EDGE: W1 FINISH � P BULLNOSE EDG : W1 FINISH p p p p p � � � o PAD❑ / � G � B �� � COPIER � � � � � � � � � G �SB DAV I �n E4D� �o � E4D PL1 PANELS I E D I u o u�� u o . o o � D E � � � � �� � o / \ / � / \ o � ' , °°� �' �°° °° ' � � �� �� � ' � °° � PARTN E RSH I P /� 0 EN � Fi E �� � � '�' �� � � i �GNA GF�� � i� '� Fi E w ARCH ITECTS 14'-5" 1, 6„ 2'-0" 1'-11" 2, 9° 2,_9» 2,_9» 2,_9„ 2'_p" 2'-103/" 3,_6» 1, 6» 2,_0» 1" �° 6�� Denverl2301 Blake Street, Suite 100 NOTE: INFILL BASE AND CROWN MOLDING AS WARRANTED BY DEMOLITION AND NEW CONSTRUCTION IN ELEVATOR LOBBY. 7 2 � Denver, CO 80205 303.861.8555 A8.0 A8.0 A8.0 Vail 0225 Main Street, Unit C101 SIMILAR SIMILAR SIMILAR Edwards, CO 81632 970.926.8960 MAPLE BULLNOSE EDGE MAPLE BULLNOSE EOGE MAPLE BULLNOSE EDGE CORRIDOR 200 - SOUTH CORRIDOR 200 - WEST RECEPTION 201 - NORTH RECEPTION 201 - EAST RECEPTION 201 - SOUTH RECEPTION 201 - WEST ��� � � 0 C ��4,. _ ,°-o„ 0 D ��4„ _ ,�-o„ 1 A ��4„ = i'-o„ 1 B ��4,. _ ,�-o„ 1 C ��4„ _ ,�-o„ 1 D ��4„ _ ,�-o„ BEAUDIN GANZE CONSULTING ENGINEERS 222 CHAPEL PLACE, UNIT AC-201 9 9 P.O. BOX 9650 A8.0 A8 � AVON, COLORADO 81620 970.949.6108 ��. 18"x24" PAINTED HOLLOW METAL LEAD LINED FRAME; RE: 6/0.2 1'-6" 1'-6" 2'-9" 2'-9" 3'-6" 1'-11„ lY" 1y" 2 2 `° 6" � EQ. EQ OPEN OPEN - _ - - _ � � TO TO `� FLAT - � � /; � � \ °' � RECEPTION RECEPTION "' ��_ �� � .�i ��� SCR�p N � , � / �, �� 4-6%" 3 -0 2 -11 3-0 2 -11 ❑❑ '` � � ° / %/ � E N i � � 1'-11" w \ 0 � � � � N � o / o _ „ �� p � / \ ED e o � o ° - ED � o � 1 3 E � � � � � VALANCE �� �� � 0 � � � �� I �' Q� I � / � w ILE i �' `�' � » 1"x4" MAPLE CHAIR RAIL (CR) � -� 4"x12" SLOT WITH 2�-$�� 2�-�� PVC EDGE AT PERIMEfER 5-2�� 2 -5" 1' 6" 1'-6' CARD READER BY TENANT; 48" TALL X 23" WIDE X 22.5" DEEP 1" 1 1 12 1 1 12 g 6 1"x4" MAPLE CHAIR RAIL (CR) 6 3 1 17 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 SIMILAR 4 A8.0 WAITING 202 HALL 216 - EAST WAITING 202 - SOUTH WAITING 202 - WEST EXAM 204 - SOUTH X-RAY 206 - WEST _ � _ � � �� 1�� 2B ��4„ _ �'-o„ 2C ��4„ = i'-o„ 2D ��4„ = i'-o„ 4C ��4„ = i'-o„ 5D ��4„ = i'-o„ /'=�pF CO� , 15 9 10 9 9 15 9 9 � � ����.Q� A8.0 A8.0 A8.0 A8•0 A8.0 A8.0 A8.0 A8.0 ��Q- '9� � �� 24 24 1" 1' 1" 1 1' � SCOTT MICHAEL � 3'-0» 2' 0" 1,_3" _3„ 2,_9„ 2'_0„ 3,_6» 3,_6„ _6° 2,_6�� 3,_6° 3�_6„ 2,_9„ 2,_9° * NEVIN * 4�„ � 202985 ��� � � � � � � �� � � � � � � � �� � ����� �� i / � / V � � _ � /� / � � � � � 1 ` - � / \ \ � � l-��� , , � � ; � � � �� � _ � 0 3/3/20'I� � � �-- � � � � - � � � � � � / I / N \ N \ \ � N � �. � I / \ 1 N � w �\ V � � � � i� . �� - - �..� � � � / L` \ / V � / � � � � / � / �. �� � � � � � � / �� � � � i i� �,i � ��� � � � � � . E _ , E - , E E , B i UB � � � � / \ � � � � UCL � p � � 0 �� 0 � � ���g o � ' � - � • �� . • � N � N � � � , e e �j- i e � e � e e � ° � - o " ' � DE C - o ° DE l' - i ° `° DE ° � „� ED„�o ° n � - pp _ pp _ - ED ED ° ED d- V ' / e w � � �� � ° � � �0� �� ° � ��0 � � `''- ��`` � ° E DOPEN E �OPE � � PEN �� � OPEN �� - o �� �� . / / � FILE / N � � FILE � � FILE � � 0 EN FILE i � � �� � ���� � OPEN � � Vail � '�� Valley 2'-9" 1'-6" 1'-6" 1'-6' 2'-0" 2'-0" 2-42 1' 6" 1'-6' 2'-6' '-5" 2'-0" 2'-0" 3'-1" 2'-6" 2-6„ �� 6° ��-6' 1'-6" 3'-7Y" 3'-7Y" 3,_5„ 3,_6,� 2,_�° 2,_6,� �� 6" �,_6„ 2�_6° 2,_6„ 14 �a � �'-3$" 1"x4" MAPLE CHAIR RAIL; 1" 1" 1' 1'-4 8" � 1 3 1 3 6 VERIFY HEIGHT WITH OWNER 1 3 6 6 1 3 17 6 7 6 Med�ca� A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 C e n te r CAST 206 - WEST CAST 206 - NORTH EXAM 20812 - WEST EXAM 209 - SOUTH EXAM 210 - SOUTH NURSE 216 - WEST P PA 212 - SOUTH P PA 212 - WEST 6D ��4„ _ ,'-o„ 6A ��4„ _ ,'-o„ 8D ��4„ _ ,'-o„ 9C ��4„ _ ,'-o„ 10C ��4„ _ ,'-o„ 1 1 D ��4„ _ ,'-o„ 12C ��4„ _ ,'-o„ 12D ��4„ _ ,'-o„ Vail Summit A8.° A8.° A8.° A8.° A8.° GENERAL NOTES AND LEGEND Orthopaedics ���� ���� 3„ 1„ �„ 1'-5" 3'-0" 1'-3" '-3" 3'-0" 3'-0" 3'-6" 3'-6" 1'-3" '-3" 3'-3" 3'-3" 3'-3" 3'-6" 2'-0" 3'-6" 2'-0" » » US Bank Buildin 1 . ALL OPEN SPACE INTERIORS OR UNDER COUNTER OPENINGS TO HAVE FINISHED g 1�' 12" 3" PLASTIC LAMINATE PANELS. SUIt@ 2O6 � � � � 2. PROVIDE EQUAL FILLER PANELS AT EACH END OF CASEWORK SECTIONS; FILLER PIECES � �� � � � � � � � � TO BE LESS THAN 3" UNLESS NOTED OTHERWISE. 1 O8 SOUth Fi"OCl�ag@ ROaCI � � � � � � 3. PROVIDE SEAM FILL AT ALL JOINTS. � � i � i � i � � i �_ � � A � - � � � � A � � � � � � » Vail Colorado 81657 w �� �i � � ' w ,� �� � ° � ,� � � , , � � � , ' � 4. PROVIDE 2 RADIUS EDGE AT EXPOSED COUNTER CORNERS. ' '� � � / '�' � � � � � � � � � � ; � � „� � � i � �� � 5. RETURN APRONS AND LIGHT VALANCES TO WALL AT EXPOSED ENDS. ` � ' ` ��' �, �� ���� � �u � �o� � `` E � � E ��� 6. CONTRACTOR TO COORDINATE BLOCKING AND COUNTERTOP SUPPORT MEMBERS. E o USB E � EUSB o E D USBE ` p � °' p � °' 7. ALL BACK AND SIDE SPLASHES TO BE 4" HIGH, UNLESS OTHERWISE NOTED; CAULK TO � - • � • u - � � � �, � � � � �, �� � � � WALL BEHIND. ALL COUNTERS TO RECEIVE BACK SPLASH UNLESS NOTED OTHERWISE. 8. UPPER CABINETS TO BE 15" DEEP, ALL COUNTERTOPS TO HAVE 24" COUNTER DEPTH, Sheet Title: ED ° w � _ � E �� w � w � ED , � ED ;` � / � ED �' �. - � ED � � - o � o UNLESS OTHERWISE NOTED. �� � � OPEN `� �� ' OPEN � � � i� �� � �� `� � � � �� � � � /� ��� ;.�, I ��� ;.�, 9. REFER TO SHEET A8.0 FOR STANDARD CASEWORK DETAILS. FLE N FILE � OP N N OPEN � FILE � OPEN � FILE � � ILE % � ILE % 10. PLASITC LAMINATE TO BE APPLIED TO ALL EXPOSED SURFACES. CABINET INTERIORS TO BE WHITE MELAMINE. 5 � ° � °° ' S " � � ' � ' � ° °° ° ° � ° ° °° ° ° � ° 2-6" 1' 6" 1'-6' 4'-5" 2-6" 1' 6" 1'-6' 11 . ALL TOILET ACCESSORIES TO BE PROVIDED BY, AND INSTALLED BY CONTRACTOR PER INTERIOR 8'-11Y" 1' 6" 2�-2/a�� 2 -1 2 -1 2 -9/ 1 -6 3-3/' 3'-1/" 2-1 2-1 1 -6 2-6 2 6 1 -6 ANSI AND ADA REQUIREMENTS. 1'-0„ �'-�" �„ �» �„ � DESIGNATES INDIVIDUALLY KEYED LOCKS; 2 KEYS PER LOCK ELEVATIONS 6 6 6 7 6 6 3 1 6 3 1 FEP FINISHED END PANEL; FLUSH WITH DOOR FRONTS A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 A8.0 �ii SOAP DISPENSER BY OWNER; CONTRACTOR TO PROVIDE BLOCKING Permit Set 3/3/2014 � ' PAPER TOWEL DISPENSER BY OWNER; CONTRACTOR TO PTD PROVIDE BLOCKING Sheet Number: ADMIN 213 - NORTH ADMIN 213 - EAST P PA 214 - WEST P PA 214 - NORTH EXAM 215 - EAST EXAM 217 - NORTH � 13A ��4„ = i'-o„ 13B ��4„ = i'-o„ 14D ��4„ = i'-o„ 14A ��4„ = i'-o„ 15B ��4„ = i'-o„ 1 7A ��4„ = i'-o' UCL UNDER COUNTER LIGHTING WITH PLASTIC LAMINATE VALANCE RETURN VALANCE TO WALL WHERE APPROPRIATE G GROMMET-TO BE LOCATED BY OWNER; PRIOR TO MOVE IN ° D TELECOMMUNICATION OUTLET � ; E ELECTRICAL OUTLET � usg USB PORT DPA Project: 14901.00.000 0 COPVRIGHT 2014-�AVIS PARTNERSHIP,P.C. ■�■ ■ ■ 9 10 10 15 ■■ . ■ - A8.0 A8.0 A8.0 A8.0 1�� �4�� ��» 1„ ■ . ■ ■ , 3'-6" 2'-0" 1'-6" 3'-0" 3'-0" 1'-6" 3'-0" 1'-6" ■ . ■ . - VANITY LIGHT; ■ ■ 1�" 1�" CENTER OVER SINK 2" X 4" BULLNOSE TRIM TILE ■ ■ ■ �� � �� � � �� � � 1" X 1" MOSAIC ACCENT TILE � � � � ALTERNATE: M 1-SPA D 148, � � a' ' ` GO � / \ w � i �, , � ' , � M2-GOLDEN GRANITE D136 MIRR R; � \ � , A / `��/ �i - �' Fi p�� HOOK BY TENANT DAV I M3-ARTISAN BROWN SPECKLE D204 \ / E � UCL � �Sg UCL �Sg o 36" GRAB BAR 18" GRAB BAR �'���- E � � � � � � � 0 �, 4" X 4" FIELD TILE 42" GRAB BAR �i � � � �� �� '�' PA RT N E R S H I P G G ARTISAN BROWN 0144 � � � � � � E D o � - E D � E D � _ _ _ SEMI-GLOSS _ ' � _ ARCH ITECTS � �� � ��OPEN ��OPEN � � ���P�� 6" X 12" TILE COVE BASE ° � � �� � � � � z \ / w F LE i � � �, - N � N N Q � � � Denverl2301 Blake Street, Suite 100 12�� X 12" FLOOR TILE Denver, CO 80205 303.861.8555 4'-5" 2' 6" 1' 6' 1'-6' 4'-g%" 4'-9%" 2'-0" 1'-6" 2�_��� PIPE INSULATION 3'-0" 1'-6' PORCELAIN - GOLD P521 VaiI10225 Main Street, Unit C101 ��� 2'_2 ��2" � 2 _2 ��2" 1" Edwards, CO 81632 970.926.8960 6 3 1 17 16 A8.0 A8.0 A8.0 A8.0 A8.0 •�� . � BEAUDIN GANZE CONSULTING ENGINEERS 222 CHAPEL PLACE, UNIT AC-201 EXAM 218 — NORTH NURSE 219 — NORTH TOILET 223 — NORTH TOILET 224 — EAST TOILET 223 — SOUTH TOILET 223 — WEST P.O. BOX9650 18A 19A 23A 24A 23C 23D AVON, COLORADO 81620 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 1/4" = 1'-0" 970.949.6108 - � - • 1 I�Y.1(� 1►C�� /'=�pF CO� / � O � � ��� ,�� � Oo � SCOTT MICHAEL * NEVIN * � 202985 ; � \\ �����i �,'�� AR�`% 3/3/20'I� �_� ' . - � . �� . . � Vail Valley Medical C enter Vail Summit GENERAL NOTES AND LEGEND Orthopaedics 1. ALL "OPEN SPACE" INTERIORS OR UNDER COUNTER OPENINGS TO HAVE FINISHED PLASTIC US Bank Building LAMINATE PANELS. SUIt@ ZO6 2. PROVIDE EQUAL FILLER PANELS AT EACH END OF CASEWORK SECTIONS; FILLER PIECES TO BE LESS THAN 3" UNLESS NOTED OTHERWISE. �OS SOUtII Fi"OClta e Road 3. PROVIDE SEAM FILL AT ALL JOINTS. g 4. PROVIDE 2" RADIUS EDGE AT EXPOSED COUNTER CORNERS. Val�, Colorado 81657 5. RETURN APRONS AND LIGHT VALANCES TO WALL AT EXPOSED ENDS. 6. CONTRACTOR TO COORDINATE BLOCKING AND COUNTERTOP SUPPORT MEMBERS. 7. ALL BACK AND SIDE SPLASHES TO BE 4" HIGH, UNLESS OTHERWISE NOTED; CAULK TO WALL � _ � � � �� . � � BEHIND. ALL COUNTERS TO RECEIVE BACK SPLASH UNLESS NOTED OTHERWISE. 8. UPPER CABINETS TO BE 15�� DEEP, ALL COUNTERTOPS TO HAVE 24�� COUNTER DEPTH, UNLESS Sheet Title: OTHERWISE NOTED. 9. REFER TO SHEET A8.0 FOR STANDARD CASEWORK DETAILS. 10. PLASITC LAMINATE TO BE APPLIED TO ALL EXPOSED SURFACES. CABINET INTERIORS TO BE WHITE MELAMINE. ADA REQOUIREMENTSSSORIES TO BE PROVIDED BY, AND INSTALLED BY CONTRACTOR PER ANSI AND I NTERIOR `� DESIGNATES INDIVIDUALLY KEYED LOCKS; 2 KEYS PER LOCK ELEVATIONS FEP FINISHED END PANEL; FLUSH WITH DOOR FRONTS �i SOAP DISPENSER BY OWNER; CONTRACTOR TO PROVIDE BLOCKWG Permit Set 3/3/2014 PAPER TOWEL DISPENSER BY OWNER; CONTRACTOR TO PTD PROVIDE BLOCKING Sheet Number: UCL UNDER COUNTER LIGHTING WITH PLASTIC LAMINATE VALANCE RETURN VALANCE TO WALL WHERE APPROPRIATE G GROMMET-TO BE LOCATED BY OWNER; PRIOR TO MOVE IN � D TELECOMMUNICATION OUTLET � ; E ELECTRICAL OUTLET � usB USB PORT DPA Project: 14901.00.000 0 COPVRIGHT 2014-�AVIS PARTNERSHIP,P.C. ■�■ ■ ■ MAPLE BULLNOSE EDGE MAPLE BULLNOSE EDGE ■■ . ■ - MAPLE ■ . ■ Z'-�° 2'-�° AT RECEPTION CASEWORK 2�_��� 2�_1�� AT RECEPTION CASEWORK 2'-�° BULLNOSE ��� �" �" EDGE AT ■ , � RECEPTION � � GYP. BD. _ casEwoRK � � � , -� GYP. BD. � ` � � '� .� � �, � � �,,�� _�,.��� GYP. BD. �,. ���.��� ����� � � GYP. BD. � :., � GYP. BD. � 4" BACKSPLASH ��>:�� :�� ���� �:��.����� �. °� �.. � ;� „ � 4 BACKSPLASH �' , ' � �� � � � �� � �� � �.,�� _ ,_�_�_� ,� �.;_� ,�,��� PLAM COUNTERTOP WITH PVC EDGE ��, � °� 4 BACKSPLASH ��� DRAWER �� =� 4" BACKSPLASH � � 4" BACKSPLASH -'_ � � � � �` ''�a DRAWER � RECESSED DRAWER �� � TO MATCH LAMINATE � COUNTER TOP STANDARDS -_ � � _ � � - SINK �' 1 1�4" P. LAM. COUNTERTOP � � � �� �;� 1 1�4" P. LAM. COUNTERTOP ; 1 1�4" P. LAM. COUNTERTOP RECESSED ������������ ����� � 3/" FRONTS DAV I � ; : = �; ��.�. � _�,���� �STANDARDS DRAWER � � 20 GA. SHEET METAL BACKING � � �� � 18 GA. SHEET METAL BACKING � � �� __ _ � ADJ. SHELF � CONT. BEHIND CASEWORK � CONT. BEHIND CASEWORK ; � _ 18 GA. SHEET METAL BACKING DRAWER - 34" FRONTS PA RT N E R S H I P - ADJ. SHELF ' � � '� - PLASTIC LAMINATE ON ALL � �� ° � o � ° CONT. BEHIND CASEWORK � `� ° �$ � ° �$ EXPOSED SURFACES � ° / FRONTS ; N /" FRONTS � � � 3 � � GA. SHEET MEfAL BACKING�� � � � ;.�, GA. SHEET MEfAL BACKING�� -� '�' A R C H I T E C T S 3 � 3 � /a" FRONTS ��� CONT. BEHIND CASEWORK � CONT. BEH�ND CASEWORK Ya" PLYWOOD BACKING � Ya" PLYWOOD BACKING � � Ya" PLYWOOD BACKING g 1�2"x11 FILE DRAWER � � Ya" PLYWOOD BACKING ADJ. SHELF �� Ya" PLYWOOD BACKING � Denver 2301 Blake Street, Suite 100 1 x WOOD BLOCKING 1 x WOOD BLOCKING 1 x WOOD BLOCKING I 1 x WOOD BLOCKING 1 x WOOD BLOCKING PRINTER DRAWER IDenver, CO 80205 303.861.8555 - ON GLIDES 2x WOOD BLOCKING �,�,..,�,.���.� _ ,.��,,������ ;. �,�,:�. ; 2x WOOD BLOCKING ��.� , . ,.,�.�.� . �,,,�:, : �,"�..��;; 2x WOOD BLOCKING '- ��� 2x WOOD BLOCKING � � , � , 2x WOOD BLOCKING �'� -_ "' Vai1�0225 Main Street, Unit C101 � Edwards, CO 81632 970.926.8960 �, � � �� � � \\ � `',\ � � � 3°� 3„ 3.� �,_9» 3•� •� � . � � 3" BEAUDIN GANZE CONSULTING ENGINEERS 1 SINK BASE 2 CABINET W ADJUSTABLE SHELF AND DRAWER 3 CABINET WITH DRAWERS 4 CABINET W EQUIPMENT 5 PRINTER DRAWER 222CHAPELPLACE, UNITAC-201 P.O. BOX 9650 A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" AVON, COLORADO 81620 970.949.6108 — �.,_ _ PROVIDE PLASTIC PLASTIC LAMINATE LAMINATE ON ALL PLASTIC LAMINATE -- — FILLER PANEL EXPOSED SURFACES, 2�_�» FILLER PANEL UNLESS NOTED PLASTIC LAMINATE OVER MDF BOARD 2'-1" U.N.O. OTHERWISE �" _ '� � CEILING TILE � COUNTERTOP � -� GYP. BD. ° � � CEILING TILE _ _ - 4" PLASTIC LAMINATE BACKSPLASH GYP. BD. . , - � 4" BACKSPLASH ��° ��°������ `����� �� � ���'�� ���� �� ADJUSTABLE SHELVES; 2" GROMMET AS REQUIRED � � PLASTIC LAMINATE COUNTERTOP „ �- RE:��INTERIORSHELVES; � � RE: INTERIOR _ � ELEVATIONS FOR „ � .. �>� :<� WITH PVC EDGE ; ��A��. � ��A�'`. ��.� ��.�, �. �� �:�.�:�'�� ��°��,_� � � �-�� . �� ��i , A �, \ NUMBER OF SHELVES 4 BACKSPLASH � `� � � ELEVATIONS FOR z � �� �� GYP. BD. o NUMBER OF SHELVES GYP. BD. � ��`���� �� ° z 1 x4 WOOD BLOCKING; �` �� DRAWER ` �. SINK � � ,,� �.. . PAINT TO MATCH WALL � COUNTER TOP ' '_, 3/4" P.LAM. Q �_ �� � ° 1 3 � � n J Q 1'-3" � 1 8 G A. S H E E T M E T A L B A C K I N G ,�, � 18 GA. SHEET METAL BACKING 3 4" P.LAM. REMOVABLE PANEL $ WOOD 18 GA. SHEET METAL BACKING ; CONT. BEHIND CASEWORK w w 1 8 G A. S H E E T M E T A L B A C K I N G DRAWER � _ w _ C O N T. B E H I N D C A S E W O R K _ � � /•, B L O C K I N G C O N T. B E H I N D C A S E W O R K w � �, w � CONT. BEHIND CASEWORK SURFACE MOUNTED TUBE STEEL � o ` 2X2 STEEL TUBE SUPPORT _ �' � , ���� ; ,� ,��,°. � `�' ``' SECURED BEfWEEN TWO (2) �� `� /a' FRONTS � CO SUPPORTS AS REQUIRE � � � 3/a' FRONTS � � 3 � �' ;�, %" FRONTS ,� ���� � ", � Q VERT. STUDS. CLEAT TO WALL, �� > RECESSED Q MAX. SPACING 42" O.C. Ya" PLYWOOD BACKING � �N N Ya PLYWOOD BACKING RECESSED ¢ Ya PLYWOOD BACKING STDS. � 1 x WOOD BLOCKING DRAWER -�' WOOD BLOCKIN t x WOOD BLOCKING STDS. 1 x WOOD BLOCKING , 5" �,���,� 2x WOOD BLOCKING � � � — �� ���`�� ��'�'����"��� � ������ � � NOTE: COMPLETELY �- �' ` �; � NOTE: COMPLETELY IN-FILL UNDERSIDE OF � \ � IN-FILL UNDERSIDE OF CABINEIS INCLUDING � CABINETS INCLUDING �%� CORNERS, SEAM-FILL � 3 CORNERS, SEAM-FILL ALL JOINTS. COMPACT FLUORESCENT ALL JOINTS. FIXTURE; SOME LOCATIONS ' : ' •� ��� 1►� 6 COUNTER TOP 7 3 DRAWER FILE CABINET 8 SINK WITH VALANCE 9 UPPER CABINET W ADJUSTABLE SHELVES 10 UPPER CABINET WITH LIGHT VA�ANCE % � ���� A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" �Q' � `\'Q � �SCOTT MICHAEL 1 O * NEVIN * P-LAM TRANSACTION � � �0���� COUNTER WITH MAPLE ��� ����� BULLNOSE EDGE: W1 FINISH 1' DIA. STAINLESS STEEL SUPPORT ` � PEGS � 3/3/20'I �A� ��-a• 3/4" PL 1 WRAPPED PLYWOOD --— —_ 3/4" PL1 ON HIGH — - DENSITY PART�CLE BOARD �� FRT WOOD BLOCKING �' � 1-1/2" DIA. CORD HOLE MAPLE BULLNOSE EDGE � FIRE EXTINGUISHER IN SEMI-RECESSED, � � - � � ��, �� PLASTIC FRT WOOD BLOCKING ; W1 FINISH w LINED W/ GROMMEf, TrP. � ENAMELED STEEL CABINEf WITH SOLID �STANDARDS FLMERTPANEL P-LAM COUNTERTOP 2�_�• � P-LAM COUNTERTOP 2�-i i�2° ����o• Q - DOOR WITH BLACK, VERTICAL, VINYL � ,, ; � LETTERS; LARSEN'S MANUFACTURING 3/4" MAPLE WOOD - '\ 3/4" MAPLE WOOD � COMPANY OR EQUAL CABINEf TO BE • VENEER PANEL: W1 \ VENEER PANEL: W1 � � PAINTED TO MATCH WALL EXTINGUISHER V��� `""' " ' FwisH FiNisH i� �; � m TO BE MULTIPURPOSE DRY CHEMICAL � ¢ TYPE IN STEEL CONTAINER 5 LB AND UL 3 4" PL 1 WRAPPED PLYWOOD 3 4" PL 1 WRAPPED PLYWOOD� U r.,� MELAMINE / / w INTERIORS; o � Z � o RATED. CONTRACTOR TO PROVIDE AND alley TYPICAL � � o � INSTALL EXTINGUISHER AND CABINEf. 2X2 STEEL TUBE p O � SUPPORT SECURED o 2X2 STEEI TUBE o � Medical BETWEEN TWO (2) VERT. � � SUPPORT SECURED � �i N U O STUDS. CLEAT TO WALL, <., BEfWEEN TWO (2) VERT. �., ' MAX. SPACING 42" O.C. STUDS. CLEAT TO WALL, G° MAX. SPACING 42" O.C. I C enter 4" HIGH MAPLE WOOD � BASE: W1 FINISH � 4" HIGH MAPLE WOOD ' I � I 4" HIGH RUBBER COVE � BASE: W1 FINISH BASE ` 4" HIGH RUBBER COVE BASE ",;, a � , ; ,: , , , � � Vail Summit 11 SECTION AT RECEPTION DESK 12 SECTION AT RECEPTION DESK 13 NOT USED 14 FIRE EQUIPMENT CABINET SECTION OI"tI10 aedics A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1' 0" A8.0 1" = 1'-0" p 1 � � � US Bank Building `' ' ' ' " ' ' ` ""' °"�'�'�� 2'_�" PVC EDGE 2'_�" PVC EDGE SUI�@ ZO6 cYP. B�. ��� — 108 South Frontage Road GYP. BD. ' ' GYP. BD. VaII, Colorado 81657 20 GA. SHEET METAL BACKING� � a � a � � CONT.��3E�1����� '�� P.LAM BACKSPLASH " P.LAM BACKSPLASH � ` ����`° ' � s � o ,,.� x ,.,� Ya" PLYWOOD BACKING I�� � P.LAM COUNTERTOP � P.LAM COUNTERTOP _ %� ATTACH MEfAL STUDS � � � • ��� •� `� � � TO DECK ABOVE ATTACH METAL STUDS � SINK �1� J 3/4" P.LAM. Y 3/4" P.LAM. TO DECK ABOVE Sheet Title: � - z � PIPE INSULATION � 0 v� � o %" FRONT N o � EXTEND GYPSUM BOARD 6 EXTEND GYPSUM BOARD 6" I o I ABOVE FINISHED CEILING A V FINI H IL IN I N TE R I O R x B O E S E D C E E G 2x WOOD BLOCKING ,. ..,.. � ACOUSTICAL CEILING TILE ACOUSTICAL CEILING TILE D ETAI LS � VARIES d- \ � 7'-8" A.F.F. 1'-9" 3" PLASTIC LAMINATE ON ALL PLASTIC LAMINATE ON ALL EXPOSED SURFACES EXPOSED SURFACES 3%" METAL STUDS; UNO. SEE RCP 3%" METAL STUDS; uNO. Permit Set 3/3/2014 VARIES; %" GYPSUM BOARD Sheet Number: %" GYPSUM BOARD 0 o � � 15 SECTION THRU FULL HEIGHT CABINET 16 SECTION THRU SINK ARPON 17 NURSE DESK 18 SOFFIT DETAIL 19 DROPPED HEADER DETAIL � � A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" A8.0 1" = 1'-0" DPA Project: 14901.00.000 0 COPVRIGHT 2014-DAVIS PARTNERSHIP,P.C. � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � •■ ■ • • RC P KEYN OTES � ■■ . ■ - I � ■ � ■ � � ' ADMIN WORK I � ■ . ■ . - 1O NO WORK IN THIS AREA. ' 2 3 O O O � I O ■ ■ ■ ■■ S S S O2 MODIFY CROWN MOLDING AT REQUIRED BY NEW WALL CONSTRUCTION. ' � — O O � O3 MODIFY GRID AT REQUIRED BY NEW WALL CONSTRUCTION. � DAV I S ' O O WAITING O O ❑ � O DROPPED HEADER; RE: 19/A8.0 ' I ° � PARTNERSHIP 8'-0" O DROPPED SOFFIT; RE: 18/A8.0 ' OO OO OO � A R C H I T E C T S 8'-0'> ' � �' I e ' I2301 Blake Street, Suite 100 O SOFFIT; RE: 18/A8.0 SIMILAR Denver Denver, CO 80205 303.861.8555 ' j' I I I I 0 6 +� 0225 Main Street, Unit C101 .���.� :°��. ' V ail ,°. �,.,, ',�:::. F— —� CORRIDOR O E w r 1 2 7 . 2 . I d a ds CO 8 63 9 0 9 6 8960 ,..��`�T , 1::�'. -�8:- �.n� .`:��-'�. �� ���,I..; �.:: ',�.: 2 200 � ��.��:,:",:�^.��i.� ,.�'`;:r`.,`..'.,` ' I .�::,` ❑ � � ;.�; ' R P N TE C O S ' 5 - 5 ' � � � X-RAY � :s":Q::':: ' I 205 I SEPARATE O BEAUDW GANZE CONSULTING ENGINEERS 1 . LIGHTING AND CEILING TO BE CENTERED IN ROOM OR HALL. , � O 9�_�» \\ DIMMER I 222 CHAPEL PLACE, UNIT AC-201 O I � O SWITCH P.O. BOX 9650 ' U ::'J.��� !, ' AVON, COLORADO 81620 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF LIGHT FIXTURES, �,�'�/ EXAM 970.949.6108 REFER TO ELECTRICAL DRAWINGS FOR FIXTURE SIZES AND TYPES, EXIT SIGNS, *y 204 ���� SPEAKERS, SMOKE DETECTORS, AND ADA REQUIRED DEVICES. REFER TO ' � 7'-0" TOP OF � O O -`��•�' �'�' RECEPTION ' SIZESANICAL DRAWINGS FOR LOCATION AND SIZES GRILLE LOCATIONS AND ' , I I WALL BELOW �2 6T O 20� 8 -� •�',:�:'::,;�.;.,;.�:;:, O 0 � 0 � 5 6 '� ' ' I g'-p" O �� I RCP LEGEND ' " — — 8 -� u STRUCTURE ;;-� ' ABOVE GRID 6 :'j ' 1O , „ _ •:.j '>.` `},=. ;:�i 7 - 9 `� I;;` ' :.�:•�.wg: . _ I :�:j:.,'': ;r;;. INDICATES EXSITING WALL � ;'� s,� ., INDICATES NEW WALL I O NURSE O I O H o�� I O 8�_�� � _ 211 �� INDICATES NEW DOOR ' ! � _` —�� INDICATES EXSITING DOOR � -9 ���, � � �..' � � ' O 4 INDICATES NEW 2'x4' CEILING GRID O EXAM WITH NEW ACOUSTICAL CEILING TILE/ACT 1 ' O 217 E2,oM O O E2osM O O � INDICATES NEW 2'x2' CEILING GRID I EXAM 2os ' WITH NEW ACOUSTICAL CEILING TILE/ACT 2 , „ ' 8 -0 . . ' O � a O HALL ' . .. O O 2�s ' • � :. . : INDICATES GYPSUM BOARD CEILING OR SOFFIT P PA , „ r�� 1� ' b 8'-0" . . � . ziz g -0 � F C � � , „ 8�_�» � � � Q � � ���,'� �Q INDICATES NEW 2'x4' RECESSED O ' �� O FLUORESCENT FIXTURE ' EXAM C� � 0 INDICATES NEW 2'x2' RECESSED 8>_�» �E2 5M 218 * SCOTT MICHAEL * 8'-0" ' NEVIN � FLUORESCENT FIXTURE I O g'-p° 202985 � � INDICATES INCANDESCENT FIXTURE , „ O O ' `jC\ � � 8 -0 , INDICATES INCANDESCENT ART LIGHT FIXTURE O O g'-p" � � �� ��� A���� � a � ��� � � � 3/3/20 Q INDICATES INCANDESCENT PENDANT LIGHT FIXTURE O P PA O I � � 214 ��� I-9—I INDICATES UNDER CABINET FLUORESCENT FIXTURE O O I OATS � ' � � '�' � � � INDICATES SUSPENDED FLUORESCENT FIXTURE 220 4 2I INDICATES MECHANICAL ' ADMIN NURSE I � RETURN DIFFUSER �`� 213 219 • � � Va�l HALL > » CORRIDOR INDICATES MECHANICAL O 22i � 8 —� O 230 � SUPPLY DIFFUSER ' ' ��11� , ' O-�� 8'-0" � .. � INDICATES RECESSED SPEAKER FOR OWNER � � I Medical PROVIDED SOUND SYSTEM ' _ . �. � - � �� 3 `.� _^. �. �... �. � . - H223L _�.. ' Center ' . .� . ."' . �;_�.>, .. �--C�—� ' ' .. 2;_6,.. �'-0,` � ..2,_s„ SER 2ER O � O �OIL�T O I ' �. �: '�. � ;224. . . . , � . ' � � OPEN OFFIC ' Vail Summit I 8�-°,. 29 � - Orthopaedics � ' 8�-0�� � I ORAGE 226 US Bank Building I I I Suite 206 � � 8'-0 � OFFIC� � 108 South Frontage Road 22� ' OFFICE�' � Vail, Colorado 81657 I BREAK 22s O J O 225 O O O � ' O ' ' � - - I � � 11. •� � Sheet Title: � ' � �� � � /�, � — � � REFLECTED CEILING PLAN AND NOTES � — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — � Permit Set 3/3/2014 Sheet Number: o � REFLECTED CEILING PLAN . N � A9.0 1 /4" = 1 '-0" 0 2' 4' 3 � DPA Project: 14901.00.000 0 COPVRIGHT 2014-DAVIS PARTNERSHIP,P.C. ■�■ ■ ■ DESIGN CONDITIONS FIXTURE CONNECTION SCHEDULE PLAN ABBREVIATIONS DUCTWORK LEGEND PIPING SYMBOLS PIPING DESIGNATIONS ■■ . ■ � PARAMETER WINTER SUMMER ABBREV. HW CW WASTE VENT AAV AIR ADMITTANCE VALVE SINGLE LINE DESCRIPTION DOUBLE LINE C 90° ELBOW DN HYDRONIC PIPING ■ . ■ WATER CLOSET FLUSH VALVE - ABV ABOVE � 90° ELBOW UP -CHS- CHILLED WATER SUPPLY ■ • OSA DRY BULB(°F) -15 85 ( ) WC I 1" I 4" 2" I ■ . ■ - �� 90° ELBOW DOWN (ROUND DUCT ONLY) � i . OSA WET BULB(°F) - 58 WATER C�OSET(FLUSH TANK) WCT - � 1/2" 4" 2" AFF ABOVE FINISHED FLOOR .. TEE DOWN -CHR- CHILLED WATER RETURN INDOOR DRY BULB(°F) 72 �5 URINAL(BLOWOUT) UR - 1" I 2" _1-1/2"_ AFG ABOVE FINISHED GRADE —O— TEE UP _ -HWS- HEATING WATER SUPPLY ■ ■ ■ ■■ �O ROUND 90° ELBOW UP(ROUND DUCT ONLY) � URINAL(WASHDOWN) UR - � 3/4" 2" 1-1/2" AUTO AUTOMATIC ��� BUTTERFLY VALVE -HWR-I HEATING WATER RETURN URINAL(WATERLESS) UR - - 2" 1-1/2" BCS BUILDING CONTROL SYSTEM � OFFSET TO CHANGE ELEVATION � �Q— SHUT OFF(BALL,GATE, BUTTERFLY) PLUMBING PIPING �� (AT 30°WHEN POSSIBLE) DAV I S LAVATORY LAV 1/2" 1/2" I 1-1/2" 1-1/2" BDD BACK DRAFT DAMPER D= DROP R=RISE � —D�4— GLOBE VALVE —G— NATURAL GAS NOTE: - CONTRACTOR MUST KEEP IN MIND THAT THIS IS A HAND SINK HS 1/2" 1/2" 1-1/2" 1-1/2" BFG BELOW FINISHED GRADE —VF— CHECK VALVE —MG— MEDIUM PRESSURE GAS I I REMODEL PROJECT. READ GENERAL NOTES � ROUND RADIUS ELBOW � ` , CAREFULLY. CONTRACTORS MUST COORDWATE SERVICE SINK SS 1/2" I 1/2" I 3" 2" BLDG BUILDING i �� FLOW CONTROL VALVE —PG— I PROPANE GAS PA RT N E RS H I P v NEW AND EXISTING CONDITIONS FOR MOP SERVICE BASIN MSB 3/4" 3/4" 3" 2" BOP BOTTOM OF PIPE FROM FINISHED FLOOR —�1— BALL VALVE —LPG— LIQUID PROPANE GAS INSTALLATION OF THE WORK. - - - • � -- 90°STRAIGHT TEE - A R C H I T E C T S DRINKING FOUNTAIN/E.W.C. DF - 1/2" 1-1/2" 1-1/2" B/N BETWEEN � --10�— PLUG OR BALANCING VALVE —PD— PROPANE DRAIN KITCHEN SINK W/OR W/O DISPOSER KS 1/2" 1/2" I 2" 1-1/2" C COMMON � FLOW BALANCING VALVE � 90°CONICAL TEE � 2301 Blake Street, Suite 100 BATHTUB/SHOWER SH 3/4" 3/4" 2" 1-1/2" CA COMBUSTION AIR I � PLUG VALVE IN RISER — D —� DRAIN PIPE Denver IDenver, CO 80205 303.861.8555 F I R E P R 0 T E C T I 0 N N 0 T E S . CLOTHES WASHER ROUGH-IN CW 1/2" 1/2" I 2" 1-1/2" CC CONTROLS CONTRACTOR � � GATE OR GLOBE VALVE IN RISER ---I DOMESTIC WATER(CW/DW) 45° BRANCH 0225 Main Street, Unit C101 DISH MACHINE ROUGH-IN DM 3/4" 3/4" 2" 1-1/2" CDBBC CONTINUATION DESIGN BUILD _ � DRAIN VALVE W/HOSE END ---- DOMESTIC HOT WATER(HW/DHW) Vail I Edwards, CO 81632 970.926.8960 1. FIRE PROTECTION ELEMENTS SHOWN HEREIN ARE BY CONTRACTOR FOR COORDINATION PURPOSES ONLY.THE DISHWASHER ROUGH-IN DW 1/2" - 2" 1-1/2" �— TEMPERATURE CONTROL VALVE(2-WAY) ----- I DHW RECIRCULATION(HWC/DHR) ENGINEERING SEAL AFFIXED TO ANY PART OF THIS 45°CONICAL TEE DOCUMENT SET AND ANY RESPONSIBILITY OF BAR SINK BS 1/2" 1/2" 1-1/2" 1-1/2" CFM CUBIC FEET PER MINUTE(AIR FLOW RATE) � � TEMPERATURE CONTROL VALVE(3-WAY) -140°--- DOMESTIC HOT WATER(TEMP.SHOWN) Consultant ENGINEER OF RECORD EXPRESSLY EXCLUDES ANY FLOOR SINK FS - - � 3" 2" CIP CAST IN PLACE ---Da— PRESSURE REDUCING VALVE —NS— NON-SOFTENED DOMESTIC WATER AND ALL FIRE PROTECTION ELEMENTS SHOWN - - �-� SIZE OR SHAPE TRANSITION �Q-� - - HEREIN. FLOOR DRAIN FD - - I 2" 1-1/2" CLG CEILING(OR COOLING) —PQ— SOLENOID VALVE — W — WASTE PIPE 2. THE FIRE PROTECTION CONTRACTOR WHO IS THE TROUGH DRAIN TD - - 3" 2" CONC CONCRETE ��— VENTURI/FLOW INDICATOR —V— PLUMBING VENT PIPE WINNING BIDDER SHALL RETAIN THE SERVICES OF A �� ROUND FLEXIBLE DUCT WORK SINK WS 3/4" I 3/4" I 2" 1-1/2" COND CONDENSATE ��- PUMP&EQUIPMENT CONNECTOR REGISTERED PROFESSIONAL FIRE PROTECTION B EAU DI N ENGINEER.SAID FIRE PROTECTION ENGINEER SHALL HOSE BIB HB - 3/4" - - CONN CONNECT I -��F— PIPE UNION PERFORM ALL DESIGN CALCULATIONS, PROVIDE A - �� 90° ELBOW DN (NEGATIVE PRESSURE) � � AIR DEVICE DESIGNATION KEY Cj ANZE / COMPLETELY DESIGNED FIRE PROTECTION SYSTEM CONTR'R CONTRACTOR -D4V�p4- DOUBLE CHECK BACKFLOW PREVENTER IN A SEPARATE DOCUMENT SET,AND SHALL BE THE I CO CLEANOUT I—r�� �� PIPE ANCHOR Consulting Engineers, Inc. ENGINEER OF RECORD FOR THE FIRE PROTECTION �� 90° ELBOW DN (POSITIVE PRESSURE) � I i x J Vail: (970) 949-6108 COPYRIGHT 2014 SYSTEM. NOTES: COTG CLEANOUT TO GRADE � � PIPE EXPANSION JOINT Denver: (303) 278-3820 Project No:8739.41 TYPE OF AIR DEVICE RE: Fort Collins: (9�0) 221-5s91 1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZES MAY BE CW COLD WATER --�- FLEXIBLE CONNECTOR GRD SCHEDULE. Albuquerque: (505)323-9070 3. THE FIRE PROTECTION SYSTEM SHALL BE DESIGNED �Q 90° ELBOW UP(NEGATIVE PRESSURE) - Jackson: (307)739-3944 IN ACCORDANCE WITH NFPA, LOCAL CODES AND INDICATED ON PLANS WHERE REQUIRED. DHR DOMESTIC HOT WATER RECIRC � SAFETY RELIEF VALVE #=AIR QUANTITY(CFM) www.bece.com ORDINANCES,AND FACTORY MUTUAL WHERE 2. MINIMUM DOMESTIC PIPE SIZE TO 2 OR MORE FIXTURES IS 3/4". - � - CA=COMB.AIR 3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE SIZES. DHW DOMESTIC HOT WATER � AIR VENT APPLICABLE. 4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY. WHERE �e 90° ELBOW UP(POSITIVE PRESSURE) � OSA=OUTSIDE AIR ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZES MAY VARY DN DOWN � PRESSURE-TEMP.TAP A 150 RET=RETURN WHEN CIRCUIT VENTS, COMMON VENTS,WASTE STACK VENTS,WET VENTS,OR 12x6 EXH= EXHAUST DW DOMESTIC WATER PRESSURE GAUGE W/PIG TAIL&COCK XFR=TRANSFER B I D A D D A LT E R N AT I V E S . COMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIOR APPROVAL FROM THE - 90° RADIUS ELBOW � � ENGINEER IS REQUIRED TO USE THESE ALTERNATIVE VENTING METHODS. DWR DOMESTIC HOT WATER RECIRC 5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT LOCATED IN 4 THERMOMETER S I Z E(I N C H E S)O R M I N I M U M FOOD SERVICE AREAS. (E) EXISTING FREE AREA REQUIRED IN 1. AS A SEPARATE LINE ITEM, PR OVIDE PRICE ADD T O REPLACE 90° RADIUS ELBOW W/TURNING VANES SQUARE FEET (E)VAV TERMINALS SERVING BREAK ROOM/STORAGE/ 6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2". EA EXHAUST AIR � VACUUM BREAKER � � RESTROOM WITH FP-7 AND OFFICE/CONFERENCE SPACES 7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT. NOTE: FOR STANDARD MODULE SIZE ���-- ..��� EAT ENTERING AIR TEMPERATURE HORIZONTAL CLEANOUT ii 227-229 WITH FB-6. ASSOCIATED E PNEUMATIC 8. REFER TO APPLIANCE SCHEDULES(BY OTHERS)FOR ADDITIONAL PLUMBING FIXTURE � REGISTERS,SIZE GIVEN IS NECK � J ( '��d � � SQUARE DUCT SPLIT CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS,AND GARBAGE DISPOSALS. SIZE. REFER TO GRD SCHEDULE ''F; THERMOSTATS TO BE REPLACED WITH NEW MODELS. DEMO EC ELECTRICAL CONTRACTOR �1 VERTICAL CLEANOUT +C���' /,y,� tn� AND RELOCATION OF SUPPLY AND RETURN DIFFUSERS STILL 9. PROVIDE ICE MAKER BOX ROUGH IN W/1/2"CW CONNECTION FOR ALL REFRIGERATOR _ . - FOR MODULE SIZE. � (��I�. �. REQUIRED AT BREAK ROOM, STORAGE,AND A RESTROOM LOCATIONS. EWT ENTERING WATER TEMPERATURE Q FLOOR DRAIN � ���fl' ; SPACES TO MEET NEW LAYOUT AND CEILING PROGRAM. � ROUND DUCT SPLIT XFR , �a{�+:� EXH EXHAUST � � FLOOR SINK /1�_ .fg', '� i � FBO FURNISHED BY OWNER � ROOF DRAIN ���� 12x6 � A , . "�. SPLIT BRANCH TAKE-OFF WITH SQUARE � � ���'' "`��� . ELBOW&SPLITTER DAMPER '`�f���'� FCO FLOOR CLEANOUT �—� � STRAINER W/BLOW-OFF VALVE INDICATES AIR WLET DEVICE EQUIPMENT ABBREVIATIONS FCT FOR CONTINUATION � SPLIT BRANCH TAKE-OFF WITH RADIUS � �� SHOCKABSORBER ISSUE LOG AHU AIR HANDLING UNIT FD FIRE DAMPER �—Z ELBOW&SPLITTER DAMPER FS FLOW SWITCH AS AIR SEPARATOR FSD COMBINATION FIRE/SMOKE DAMPER e POSITIVE PRESSURE RISER,TYPICALLY I e H�B HOSE BIBB Issue/Revisions Date IVO. I M E C HAN I CAL S H E ET I N D EX B BOILER(HOT WATER) GC GENERAL CONTRACTOR SUPPLY. _ REFERENCE SAMPLE BB BASE BOARD GHX GROUND HEAT EXCHANGER W H NEGATIVE PRESSURE RISER,TYPICALLY $ � 0 RETURN, EXHAUST OR OUTSIDE AIR. 0 I WALL HYDRANT ��, BT BUFFER TANK GPM GALLONS PER MINUTE(WATER FLOW RATE) n RE: B/M400 FFI � CC COILING COIL HP HORSEPOWER Tc TEMPERATURE CONTROLLER OR SENSOR # TITLE Q�� CH CHILLER HW HOT WATER ��F�g COMBINATION FIRE AND SMOKE DAMPER � �F/S �O� DECK/ROOF DRAIN ABOVE Vp � _ ♦/ FFI=FOR FURTHER INFORMATION CP CIRC PUMP HWC HOT WATER RECIRC FCT=FOR CONTINUATION M0.0 MECHANICAL COVER SHEET �/ I �� FIRE DAMPER � SHEET NUMBER M0.1 MECHANICAL SCHEDULES �/ _ _ � � CT COOLING TOWER ILO IN�IEU OF M0.2 MECHANICAL SPECIFICATIONS �/ � � CUH CABINET UNIT HEATER KW KILOWATTS DRAWING NUMBER OR DIAGRAM CV CONSTANT VOLUME BOX LAT LEAVING AIR TEMPERATURE � SMOKE DAMPER � PLAN SYMBOLS LETTER MD1.0 MECHANICAL DEMO PLAN �/ DC DUCT COIL LF LINEAR FOOT G CONTROL PANEL/RADIANT MANIFOLD REFER TO: M1.0 HVAC PLAN J �_ _I_ - -0 MOTOR OPERATED DAMPER(MOD) - coz CARBON DIOXIDE SENSOR M2.0 PLUMBING PLAN DEF DISHWASHER EXHAUST FAN LWT LEAVING WATER TEMPERATURE ^ J � I EBH ELECTRIC BASEBOARD HEATER MC MECHANICAL CONTRACTOR MAN VOLUME DAMPER, SWGLE BLADE �Y CARBON MONOXIDE SENSOR I I - - - - �, DAMPER(SBD)FOR ROUND OR<10"TALL, Q THERMOSTAT Pro ect Information M3.0 MECHANICAL DIAGRAMS �/ I I ECU EVAPORATIVE COOLING UNIT MFG MANUFACTURER OPPOSED BLADE DAMPER(OBD)>10"TALL. - � s REMOTE TEMPERATURE SENSOR M3.1 MECHANICAL CONTROLS J I I EF EXHAUST FAN MOD MOTOR OPERATED DAMPER � ERU ENERGY RECOVERY UNIT (N) NEW �BDD BACKDRAFT DAMPER - BDD Q HUMIDISTAT ET EXPANSION TANK NC NORMALLY CLOSED SP DUCT STATIC PRESSURE SENSOR � ISSUE LOG KEY: - SD SMOKE DETECTOR SD P ROOM PRESSURE SENSOR Vall U EWH ELECTRIC WATER HEATER NEC NATIONAL ELECTRIC CODE � 'ISSUED AS PART OF A SET - - - U ''NOT PART OF SET � � F FURNACE NIC NOT IN CONTRACT EPO EMERGENCY POWER OFF SWITCH 24x36 DUCT SIZE: FIRST NUMBER IS PLAN WIDTH, Valley 24x36 � "' ISSUED FOR INFORMATION ONLY Q o �—� SECOND NUMBER IS DEPTH. � POINT OF DISCONNECTION FC FAN COIL NO NORMALLY OPEN � Q M � � FP FAN POWERED BOX OA OUTSIDE AIR 9 POINT OF NEW CONNECTION • � GF GLYCOL FEEDER OBD OPPOSED BLADE VOLUME DAMPER ��� ACCESS PANEL Medlcal NP R 0 J E C T A LT I T U D E H HUMIDIFIER OC ON CENTER ��� SNOWMELT MANIFOLD C enter ri HC HEATING COIL OSA OUTSIDE AIR oH�ZOO' ABOVE SEA LEVEL HP HEATPUMP RA RETURNAIR � _ NOTES � HX HEAT EXCHANGER RE: REFER TO: KEF KITCHEN EXHAUST FAN REQ'D REQUIRED 1. ALL SYMBOLS,ABBREVIATIONS,AND DESIGNATIONS � ON LEGEND SHEET ARE NOT NECESSARILY USED ON ■ ■ � MAU MAKE-UP AIR UNIT REQ'MTS REQUIREMENTS THIS PROJECT. Va i I S u m m it � MCC MOTOR CONTROL CENTER SA SUPPLY AIR 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN Orthopaed i cs m - PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES -a MV MIXING VALVE SF SQUARE FOOT(FEET) AND NOTATION CONVENTIONS OCCURRING IN THIS a� - � P PUMP(SEE PIPING LEGEND FOR DETAILS) SP STATIC PRESSURE DRAWING SET ARE NECESSARILY DEFINED ON THESE a LEGENDS. CONSULT THE ENGINEER IN THE EVENT RF RETURN (OR RELIEF)AIR FAN SS STAINLESS STEEL SYMBOLOGY OR NOTATION INTERPRETATION IS US Bank Building -� RZ RADIANTZONE T.A. THROW-AWAY REQUIRED. SUIt@ ZO6 o - � SA SNOWMELTAREA _ TYP TYP�ca� 108 South Frontage Road � SB SUMP BASIN UNO UNLESS NOTED OTHERWISE � SF SUPPLY FAN VTR VENT THRU ROOF Val�, Colorado 81657 w � ST STORAGE TANK WCO WALL CLEANOUT Q —� w TMV THERMOSTATIC MIXING VALVE WRT WITH REGARD TO Sheet Information U m UH UNIT HEATER W/ WITH Sheet Title: � VR VARIABLE VOLUME BOX W/REHEAT W/C WATER COO�ED � �" MECHANICAL W VARIABLE VOLUME BOX _ XFR TRANSFER � WH WATER HEATER � DIAMETER _ - COVER SHEET � � � � � U � N Q O L L O �� CD/PERMIT 03/03/2014 � �, Sheet Number: .� > � � M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ PLUMBING FIXTURE SCHEDULE TERMINAL BOX SCHEDULE �� . � � MANUFACTURER* FAUCET TRIM MFR.* & MAX MIN. PRIM. �N� MIN. INLET HEATING COIL ELECTRICAL ■ . ■ SYMBOL TYPE A.D.A. FINISH ACCESSORIES � REMARKS INLET PRIM. AIR AIR HEATING UNIT FAN STREAM MANUFACTURER* ■ • & MODEL# MODEL# MARK TYPE DIA. (IN.) VALVE/ VALVE/ CFM CFM S.P. (IN. S.P. @ S.L. E.A.T. L.A.T. KW VOLT PH HP VOLT/ & MODEL# ACCESSORIES REMARKS ■ . ■ . - � CLG CFM VENT CFM W C � (IN. W.C.) DB (°F) DB (°F) PH ■ SINGLE BOWL STAINLESS JUST MFG TWO HOLES ON 4"CENTERS, ■ ■ ■ ■ P1 SINK YES STEEL SL-ADA-1617-A-GR T&S B-0892 - CENTER DRAIN PARALLEL BOTTOM ACCESS PANEL, FB-1 FAN 10 700 65 400 335 0.15 0.75 69 85 1.5 208 1 1/6 208/1 TITUS PTQP 2 MANUAL ADJ. FAN SPEED, TITUS II PNEUMATIC POWERED BDD, STANDARD LINER CONTROLS P2 - - - - - - NOT USED PARALLEL BOTTOM ACCESS PANEL, FB-2 FAN 8 350 125 � 350 225 0.15 0.75 66 85 2.0 208 3 1/6 208/3 TITUS PTQP 2 MANUAL ADJ. FAN SPEED, TITUS II PNEUMATIC DAV I S POWERED BDD, STANDARD LINER I CONTROLS ORESTROOM VITREOUS KOHLER BROOKLWE PROVIDE ASSE 1070 MIXWG PARALLEL I BOTTOM ACCESS PANEL, PA RT N E RS H I P P3 LAVATORY YES CHINA K-2202-4 T&S B-0892 - VALVE FOR EACH FIXTURE FB-3 FAN 12 1,250 100 700 600 0.15 0.75 70 85 2.5 208 3 1/4 208/3 TITUS PTQP 3 MANUAL ADJ. FAN SPEED, TITUS II PNEUMATIC AMERICAN STANDARD AMERICAN STANDARD � AMERICAN STANDARD POWERED BDD, STANDARD LINER CONTROLS A R C H I T E C T S P4 WATER CLOSET YES WHITE 3043.528 SELECTRONIC FLUSH 5905.100 SEAT LESS 1.28 GPF PARALLEL BOTTOM ACCESS PANEL, i VALVE 6065.121.002 COVER FB-4 FAN 10 640 160 500 340 0.15 0.75 67 85 2.5 208 3 1/6 208/3 TITUS PTQP 2 MANUAL ADJ. FAN SPEED, TITUS II PNEUMATIC POWERED BDD, STANDARD LINER CONTROLS FAUCET 2301 Blake Street, Suite 100 P5 MOUNTED NO CHROME - GUARDIAN G1100 _ IN ADDITION TO SWGLE BOWL - - - -- � - � Denver IDenver, CO 80205 303.861.8555 FAUCET FOR CAST ROOM SINK PARALLEL BOTTOM ACCESS PANEL, TITUS II PNEUMATIC EYEWASH FB-5 FAN 8 500 125 350 225 0.15 OJ5 61 85 2.0 208 3 1/6 208/3 2 MANUAL ADJ. FAN SPEED, - CONTROLS I0225 Main Street, Unit C101 POWERED BDD, STANDARD LINER Vail KOHLER KATHRYN KOHLER TRITON Edwards, CO 81632 970.926.8960 _ - _ ; P6 BAR SINK YES WHITE WRIST BLADES - PARALLEL BOTTOM ACCESS PANEL, TITUS II PNEUMATIC K-2330-N K-7304-5A-CP FB-6 FAN 8 500 50 i 300 250 0.15 0.75 69 85 1.5 208 3 1/6 208/3 TITUS PTQP 2 MANUAL ADJ. FAN SPEED, CONTROLS; FOR ADD MANUFACTURERS: POWERED BDD, STANDARD LINER ALT#1 Consultant FIXTURE: AMERICAN STANDARD, UNIVERSAL RUNDLE, FIAT STERN WILLIAMS PARALLEL BOTTOM ACCESS PANEL, TITUS II PNEUMATIC FAUCET: SPEAKMAN, DELTA,AMERICAN STANDARD, CHICAGO FB-7 FAN 10 650 65 400 335 0.15 0.75 69 85 1.5 208 3 � 1/6 208/3 TITUS PTQP 2 MANUAL ADJ. FAN SPEED, CONTROLS; FOR ADD DRAIN: JOSAM,WADE SMITH POWERED i BDD, STANDARD LINER i ALT#1 GENERALNOTES: MANUFACTURERS: A: � ENVIROTEC, KRUEGER, PRICE B EAUDIN B: i GENERAL NOTES: A: � Cj ANZE � B: Consulting Engineers, Inc. MECHANICAL VENTILATION (VAV SYSTEM) Vail: (970) 949-6108 COPYRIGHT2014 Denver: (303) 278-3820 project No:8739.41 Fort Collins: (970) 221-5691 EXHAUST FAN SCHEDULE Albuquerque: (505)323-9070 Jackson: (307)739-3944 ZONE OUTDOOR SPACE www.a9ce.com SPACE AREA SQ. FT. CFM/SQ.FT. PEOPLE CFM/PERSON ACH AIRFLOW (Vbz) QUANTITY FAN MOTOR S C H E D U L E N 0 T E S : ESP I MANUFACTURER* EXAM ROOM (BASED �20, 9FT CEILINGS � - - - 2 36 8 MARK TYPE VOLT/ ACCESSORIES REMARKS ON AIA GUIDELINES) 1. ALL STARTERS FOR MECHANICAL EQUIPMENT SHALL CFM SONES @ S.L. @ ALT WATTS PHASE & MODEL# BE FURNISHED UNDER THIS CONTRACT AND SET IN (IN WC� (IN WC� WAITING/ PLACE AND WIRED BY EC. EACH SHALL BE OF ONE RECEPTION 530 0.06 30/1000 SF 5 - 112 1 MANUFACTURER OR AVAILABLE THROUGH ONE BACKDRAFT DAMPER, MANUFACTURER TO FACILITATE EASE OF EF-1 CEILING 90 1.8 0.3 0.25 45 120/1 COOK GC-162 FSC, GRILLE, ISOLATORS ��__� ... �I�� MAINTENANCE. � �� ADMIN WORK 160 0.06 2 5 - 20 1 2. NOT ALL EQUIPMENT REQUIRED UNDER THIS � BACKDRAFT DAMPER, �'.'� � ��..��d CONTRACT IS NECESSARILY SPECIFIED ON THE EF-2 CEILING 400 2.8 0.25 0.2 139 120/1 COOK GC-740 FSC, GRILLE, - � SCHEDULE SHEETS. PLAN&DIAGRAM NOTATIONS ISOLATORS ' �,��I� ' ADMIN 213 120 0.06 2 5 - �� � AND PROJECT MANUAL CONTAIN EQUIPMENT MANUFACTURERS: ' { '� i SPECIFICATIONS AS WELL. -�s': '� �° `�:�c. � GREENHECK, PANASONIC, PENN ��'- �.�`" 3. NOT ALL CAPACITIES,CHARACTERISTICS,AND GENERAL NOTES: �� � �� n��� X-RAY(BASED ON CONSTRUCTION FEATURES REQUIRED ARE ����'�� AIA GUIDELINES) 240, 9FT CEILWGS - - - 2 72 � NECESSARILY INDICATED IN THE EQUIPMENT A: SCHEDULES. RE: PLANS AND SPECIFICATIONS FOR B� i ADDITIONAL REQ'MTS. NURSE 211 70 0.06 2 5 - 15 1 4 CONSTRUCTION FEATURES OF THE 9CHEDULED Issue/Revisions Date IVO. I EQUIPMENTAREHEREBYINCORPORATEDINTOTHE WATER HEATER SCHEDULE (ELECTRIC) HALL 420 0.06 - - - 26 1 PROJECT REQUIREMENTS. EQUIVALENT PRODUCTS _ PERFORMANCE AND CONSTRUCTION FEATURES STORAGE WATER ELECTRICAL SHALL MEET OR EXCEED THAT OF THE SPECIFIED RECOVERY MANUFACTURER* P/PA 212 �05 0.06 2 5 - 17 � EQUIPMENT WHETHER SCHEDULED OR NOT. MARK TYPE CAPACITY TEMP. RISE VOLT/ ACCESSORIES REMARKS (GAL.) �GPH� (°F) KW PH & MODEL# 5. NOT ALL EQUIPMENT AVAILABLE FROM LISTED "EQUIVALENT"MANUFACTURERS LISTED IS TOILET - - - - - 70 CFM EXHAUST - NECESSARILY EQUIVALENT TO THE BASIS OF DESIGN WH-1 STORAGE 66 61 80 12 208/3 AO SMITH DEN-66 HEAT TRAPS �2)6KW ELEMENTS,SIM. EQUIPMENT SPECIFIED.CONTRACTOR SHALL BE OPERATION SOLELY RESPONSIBLE FOR ANY COSTS, RESULTANT CHANGES TO OTHER DIVISIONS,AND SPATIAL MANUFACTURERS: P/PA 214 100 0.06 2 5 - 16 1 REQ'MTS FOR EQUIPMENT OTHER THAN SCHEDULED. * BRADFORD WHITE, RUUD OR STATE EQUIVALENT , - GENERAL NOTES: A: NURSE 219 80 0.06 - - - 5 1 B: vou 5�3 Project Information PUMP SCHEDULE M,4x z =0.�2 = TOTAL OSA 1 4 I p Ev 0.4 (VOt=VOU/EV� ' 35 I MOTOR U MARK SERVICE TYPE GPM TDH (FT) FLUID VOLT/ MANUFACTURER REMARKS � Q WATTS & MODEL# Vall PH � DOM HOT ALL BRONZE CONSTRUCTION � MECHANICAL VENTILATION (100 /o OSA SYSTEM, VIA (E) ERV-1 ) gF� Valley U 0 GRUNDFOS UPS 43-44 � P-1 WATER INLINE 8 13 WATER 1/6 120/1 SUITABLE FOR POTABLE � RECIRC WATER, SPEED 3 � � MANUFACTU RERS: M��1 C�l� � SPACE AREA SQ. FT. CFM/SQ.FT. AREA CFM PEOPLE CFM/PERSON PEOPLE CFM ZONE ZONE OUTDOOR SPACE * B&�,AURORA,w��o,TACO o EFFECTIVENESS AIRFLOW (VOZ) QUANTITY N GENERAL NOTES: �n��� i i c-i A: 0 � OFFICES 227,228 105 0.06 7 1 5 5 0.8 15 2 L � � GRILLE REGISTER DIFFUSER & LOUVER � CONFERENCE > > ROOM 229 215 0.06 13 10 5 50 0.8 80 1 . . � Vail Summit � ° MANUFACTURER* ' m BREAKROOM 180 , o.os 11 4 5 20 o.s 40 � SYMBOL USE PATTERN FINISH & MODEL# ACCESSORIES REMARKS Orthopaedics � a� c 24x24 PANEL SIZE, LAY-IN a TOTAL TOTAL OSA 150 O CEILING 4-WAY �/�/HITE KRUEGER SHR O.B.D. FRAME; NECK AND FACE SIZE � (Vot=Voz) SUPPLY DISCHARGE SHOWN ON PLAN, u.N.o. US Bank Building � CEILING CEILING RADIATION LAY-IN FRAME; PANEL, NECK Suite 206 o OB PERFORATED WHITE KRUEGER 6690 AND FACE SIZE SHOWN ON � RETURN DAMPER PLAN 108 South Frontage Road � MATCH SPLIT SYSTEM SCHEDULE - - vai�, Co�orado 81657 � M EXHAUST � O LOUVER STATIONAIRY RE:ARCH RUSKIN ELF6375DX - - o INDOOR FAN COIL UNIT OUTDOOR CONDENSING UNIT v AIR CONDITIONS ELECTRICAL w MaNUFacruRERS: Sheet Information v * DUTY AMBIENT LOW AMB. * GRD PRICE,TITUS m MARK CFM E.A.T. L.A.T. VOLT/ MANUFACTURER MARK CAPACITY TEMP. CONTROL MANUFACTURER ACCESSORIES REMARKS � DB/WB DB/WB TMBHL SEMBIH LE PH & MODEL# (TONS) DB (°F) DB (°F) MCA VPH� MOCP SEER & MODEL# Sheet Title: LOUVER GREENHECK, L&D, RUSKIN U (°F) (°F) GENERAL NOTES: _ � A� MECHANICAL �� I 1.1 FLA; WIND BAFFLE, LOW AMBIENT B; � FC-1 240 75 55 7.4 6.9 FROM CU-1 CARRIER 40MVC009 CU-1 3/4 95 -20 12 12011 20 13 CARRIER 38MVC009 CONTROL, CRANKCASE HEATER, - � CONDENSATE PUMP S C H E D U L E S � � MANUFACTURERS: ~ ° LENNOX,TRANE � � GENERAL NOTES: a� � A� �- o I� B: O �� CD/PERMIT 03/03/2014 � �, Sheet Number: .� > � � M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ MECHANICAL SPECIFICATIONS : �� � � � 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO DUCT. ABOVE THE CEILING ON EACH FLOOR AS A RETURN AIR PLENUM. ■ • ■ ■ . COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR 37. PRE-TAB EXERCISES REQUIRED FOR THE EXISTING ROOFTOP/AIR CONFORM TO THE REQUIREMENTS OF NFPA AND LOCAL CODE A. INSULATION THICKNESS BELOW BASED ON INSULATION ■ . ■ - ALL DIMENSIONS. 16. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE HANDLING UNITS SERVING THE SCOPE OF WORK AREAS PRIOR TO REQUIREMENTS FOR ALL MATERIAL INSTALLED IN THE RETURN AIR CONDUCTIVITY VALUE NOT EXCEEDING 0.27 BTU'IN/(HR*FT^2�°F): . SATISFACTION OF THE ARCHITECT,OWNER,AND ENGINEER. COMMENCING DEMOLITION. DETERMINE CURRENT TOTAL OPERATING PLENUM. PROVIDE A COMPLETE RETURN AIR PATH BETWEEN ALL ■ 2. ALL SUBCONTRACTORS SHALL BE LICENSED, EXPERIENCED,AND CFMS, ESP,AND LEAVING AIR TEMPERATURES AT HEATING AND COOLING RETURN AIR DEVICES(GRILLES ETC.)AND THEIR RESPECTIVE HVAC 1) DOMESTIC HOT WATER(DHW)AND DOMESTIC HOT WATER ■ ■ ■ ■ THOROUGHLY KNOWLEDGEABLE IN THEIR RESPECTIVE AREAS OF THE 17. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PERFORM HIS/HER WORK OPERATING CONDITIONS OF EACH UNIT. REPORT FINDINGS TO UNIT. MAXIMUM VELOCITY OF RETURN AIR IN PLENUM SHALL CONSTRUCTION INDUSTRY AND SHALL PERFORM IN A RESPONSIBLE IN CONFORMANCE WITH ALL APPLICABLE CODES, ORDINANCES AND LIFE GENERALLY NOT EXCEED 250 FEET PER MINUTE, NOR EXCEED 750 RECIRCULATION: ALL PIPE SIZES-1"THICK. ENGINEER FOR REVIEW AGAINST CALCULATED CFMS FOR THE SPACES. MANNER WITH ESTABLISHED CONSTRUCTION SEQUENCE, SHALL SAFETY FEATURES AS REQUIRED BY LOCAL, STATE,OR NATIONAL CONFIRM SPACE IS CAPABLE OF SUPPLYING SPECIFIED SUPPLY CFMS FEET PER MINUTE AT ANY CROSS-SECTION OF THE RETURN AIR RECOGNIZE THE PRIORITY OF THE CONSTRUCTION DOCUMENTS,AND AUTHORITIES. THE CONTRACTOR SHALL VERIFY WITH THE ARCHITECT IF AND OSA CFMS. PATH. 2) DOMESTIC COLD WATER: ALL PIPE SIZES-1/2"THICK. W EN THE�CO STRUCTI�ON OCUMENOTS AORE UONCLEAR OROBLEMS MODIFICATION OF HIS/HER WORK IS REQUIRED FOR COMPLIANCE. 53. IDENTIFICATION: LABEL ALL NEW PIPING AND EQUIPMENT. PROVIDE DAV I S 38. SUBMIT A WRITTEN BALANCE REPORT BY A NEBB OR AABC CERTIFIED 42. DUCTWORK SPECIALTIES INCONSISTENT. 18. ALL WORK OF ALL TRADES MUST BE IN STRICT COMPLIANCE, OR EXCEED FULL BAND OR STRIP TYPE MARKERS AND FLOW ARROWS ON PIPING. BALANCING CONTRACTOR. BALANCING PROCEDURES SHALL BE IN THE MINIMUM MATERIAL AND METHOD REQUIREMENTS OF THE 2012 ACCORDANCE WITH NEBB OR AABC GUIDELINES FOR PROPORTIONAL A. VOLUME AND SPLITTER DAMPERS: GALVANIZED SHEET METAL WITH PROVIDE ENGRAVED PLASTIC VALVE TAGS WITH VALVE NUMBER AND PA RT N E RS H I P 3. SUBCONTRACTORS SHALL BE RESPONSIBLE TO NOTIFY THE PRIME VERSION OF THE INTERNATIONAL BUILDING, MECHANICAL, PLUMBING, BALANCE. SUBMIT REPORT ON STANDARD NEBB FORMS OR SUBMIT VENTFABRICS, INC.,VENTLOCK OR EQUAL OPERATING HARDWARE. ATTACH WITH STANDARD CHAIN OR S-HOOKS. PROVIDE ENGRAVED CONTRACTOR OF DISCREPANCIES OR CONFLICTS IN THE ENERGY CONSERVATION,AND FIRE CODES AND THE 2011 NATIONAL PLASTIC SIGN ON OR NEAR SPECIFIED EQUIPMENT. A R C H I T E C T S CONSTRUCTION DOCUMENTS FOUND DURING BIDDING AND/OR PRIOR TO ELECTRICAL CODE, MOST CURRENT NFPA,ALL LOCAL ORDINANCES AND FORMS FOR REVIEW PRIOR TO BALANCING. MEASUREMENTS SHALL FOR ACCESSIBLE DAMPERS, PROVIDE NO.620,635 OR 637 DIAL PERFORMING THE WORK. AMENDMENTS AND MANUFACTURER'S INSTALLATION INCLUDE ALL MOTOR AMPERAGE AND VOLTAGE READINGS; MOTOR AND REGULATORS, NO.635 OR 637 SQUARE END BEARING,AND NO.635 RECOMMENDATIONS. IF A CONFLICT BETWEEN THOSE PUBLICATIONS FAN RPMS;STATIC PRESSURE AT INLET AND OUTLET OF ALL PACKAGED SPRING END BEARING,AS APPLICABLE. FOR INACCESSIBLE 54. A COMMISSIONING AGENT, RETAINED BY THE OWNER, MAY ORGANIZE A 4. EXAMINATION OF BIDDING DOCUMENTS. EXISTS,THE MOST STRINGENT REQUIREMENT SHALL APPLY. EQUIPMENT, FANS, COILS,AND FILTERS; PITOT TUBE MEASUREMENT OF DAMPERS, PROVIDE NO.666 CONCEALED DAMPER REGULATOR, FORMAL COMMISSIONING PROCESS.THE CONTRACTOR SHALL SUPPORT SUPPLY, EXHAUST, RETURN,AND OUTSIDE AIR MAIN DUCTS,AT MINIMUM WITH PAINTED COVER(COLOR BY ARCHITECT)AND BEARINGS AS THIS PROCESS AS REQUIRED. Denver I2301 Blake Street, Suite 100 A. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS 19. MECHANICAL WORK SHALL CONFORM TO THE FOLLOWING CODES: OUTSIDE AIR;VELOCITY DISTRIBUTION ACROSS THE FACE OF FILTERS; ABOVE. FOR MEDIUM PRESSURE DUCTS, PROVIDE NO.635 HIVEL Denver, CO 80205 303.861.8555 CAREFULLY,AND NOT LATER THAN SEVEN (7)DAYS PRIOR TO THE AIR INLET AND OUTLETS; INLET AND OUTLET PRESSURE AT PUMPS WITH DIAL REGULATOR AND NO.609 HIVEL END BEARING FOR ACCESSIBLE ALL LOCAL. CITY, COUNTY.AND STATE CODES FLOW CALCULATED FROM THE PUMP CURVE. DAMPERS. 0225 Main Street, Unit C101 DATE OF RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO THE 55. CONTRACTOR TO PERFORM PREVENTATIVE MAINTENANCE ON THE(E) Vail Edwards, CO 81632 970.926.8960 ARCHITECT FOR INTERPRETATION OR CORRECTION OF ANY AABC-ASSOCIATE AIR BALANCE COUNCIL RTU/AHUS INCLUDED IN SCOPE OF WORK. P.M.WORK TO INCLUDE, BUT DISCREPANCIES,AMBIGUITIES, INCONSISTENCIES, OR ERRORS ADC-AIR DIFFUSION COUNCIL A. PROVIDE BELTS AND SHEAVES AS REQUIRED FOR DRIVE CHANGES B. MULTI-LOUVER VOLUME DAMPERS: TITUS AG-35-B OPPOSED BLADE, NOT BE LIMITED TO, BELT INSPECTION, FILTER REPLACEMENT, UNIT THEREIN WHICH HE MAY DISCOVER. THE ARCHITECT WILL ISSUE AGA-AMERICAN GAS ASSOCIATION TO ADJUST FAN SPEED. ANEMOSTAT OR EQUAL. SEE DETAIL REGARDING REMOTE ACCESS CLEANING, ETC. ANY INTERPRETATION OR CORRECTION AS AN ADDENDUM. ONLY A AMCA- AIR MOVING AND CONTROL ASSOCIATION TO VOLUME DAMPERS. COIISUItallt WRITTEN INTERPRETATION OR CORRECTION BY ADDENDUM SHALL ANSI- AMERICAN NATIONAL STANDARDS INSTITUTE B. ADJUST FLOWS TO WITHIN 5%OF REQUIRED QUANTITY. WHERE 56. CONTRACTOR SHALL PERFORM ACCEPTANCE TESTING OF ALL BE BINDING. NO BIDDER SHALL RELY UPON INTERPRETATIONS OR ASHRAE- AMERICAN SOCIETY OF HEATING, REFRIGERATION,AND AIR ROOM AIR PRESSURE RELATIONSHIP ARE REQUIRED TO BE C. FIRE-SMOKE DAMPERS: RUSKIN,AIR BALANCE, INC.OR EQUAL, UL PROTECTIVE MEASURES(FIRE DAMPERS,SMOKE DAMPERS,COMBO CORRECTIONS GIVEN BY ANY OTHER METHOD. IF DISCREPANCIES, CONDITIONING ENGINEERS MAINTAINED AS SHOWN BY A DIFFERENTIAL OF SUPPLY AND LABELED AND IN CONFORMANCE WITH NFPA 90A. ALL DAMPERS TO FIRE/SMOKE DAMPERS)I.A.W. NFPA 90A, CHAPTER 7 TO DETERMINE AMBIGUITIES, INCONSISTENCIES,OR ERRORS ARE NOT COVERED BY EXHAUST/RETURN OR BY NOTE,ADJUST SUPPLY TO WITHIN 5%AND BE OUT OF AIRSTREAM,TYPE B OR C RATED FOR A MINIMUM OF 1-1/2 THAT THEY FUNCTION WHEN NEEDED IN ORDER TO RESTRICT THE ADDENDUM OR WRITTEN DIRECTIVE,CONTRACTOR SHALL INCLUDE ASME-AMERICAN SOCIETY OF MECHANICAL ENGINEERS THEN ADJUST EXHAUST/RETURN TO PROVIDE THE INDICATED ROOM HOURS(2 HOURS WHERE NOTED), UL LABEL AND AS APPROVED BY SPREAD OF FIRE AND SMOKE. IN HIS BID, LABOR MATERIALS AND METHODS OF CONSTRUCTION ASTM-AMERICAN SOCIETY OF TESTING MATERIALS PRESSURE. IF ACTUAL QUANTITY IS LESS THAN 95%, INVESTIGATE LOCAL AUTHORITIES. MOUNT DAMPERS WITHIN 16-GAGE SLEEVES B EAU DI N RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO AWWA-AMERICAN WATER WORKS ASSOCIATION CAUSE,ATTEMPT TO RECTIFY AND NOTIFY ENGINEER. SUBMITTAL HELD IN PLACE WITH RETAINING ANGLES. COORDINATE LOCATION A. RECORDS SHALL BE MAINTAINED ON ACCEPTANCE TEST RESULTS ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE ON BEHALF NFPA-NATIONAL FIRE PROTECTION ASSOCIATION OF BALANCE REPORT WITH LESS THAN REQUIRED FLOWS WITHOUT OF ACCESS PANELS TO PERMIT EASY ACCESS TO FUSIBLE LINK. AND AVAILABLE FOR INSPECTION. G ANZE / OF THE CONTRACTOR DUE TO HIS FAILURE TO MAKE THE WRITTEN OSHA-OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION EXPLANATION IS CAUSE FOR REJECTION OF REPORT. D. TURNING VANES FOR LOW PRESSURE DUCTS: SMACNA SMALL REQUESTS AS DESCRIBED ABOVE. UL-UNDERWRITERS'LABORATORIES DOUBLE VANE, PLATE NO.22B OR EQUAL,WITH AIRFOIL BLADES FOR Consulting Engineers, Inc. DUCTS 36"OR LESS IN WIDTH; SMACNA FIG.3.23 FOR DUCTS B. ALL FIRE/SMOKE/CEILING DAMPERS SHALL BE OPERATED PRIOR TO B. FAILURE TO REQUEST CLARIFICATION DURING THE BID PERIOD OF SMACNA-SHEET METAL AND AIR CONDITIONING NATIONAL C. SUBMIT THREE(3)COPIES OF ALL SUBMITTALS IN ADDITION TO ANY THE OCCUPANCY OF A BUILDING TO DETERMINE THAT THEY Vail: 9�0 949-6108 GREATER THAN 36"WIDE. FOR MEDIUM PRESSURE DUCTS: SMACNA � � COPYRIGHT2014 ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE THE ASSOCIATION REQUIRED BY THE CONTRACTOR AND HIS SUPPLIERS. THESE FUNCTION I.A.W.THE REQUIREMENTS OF NFPA 90A. Denver: (303) 278-3820 Project No:8739.41 GVI-GAS VENT INSTITUTE, EDITION 10-A COPIES SHALL BE RETAINED BY THE OWNER,ARCHITECT,AND FIG. 3-23. FortCollins: (970) 221-5691 CONTRACTOR OF HIS RESPONSIBILITIES. THE SIGNING OF THE Albuquerque: (505)323-9070 CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING THAT ENGINEER. C. FIRE/SMOKE/CEILING DAMPER CONTROLS REQUIRED BY CHAPTER 6 Jackson: (307)739-3944 THE CONTRACTOR HAS A THOROUGH COMPREHENSION OF THE 20. PAY FOR AND SECURE ALL REQUIRED PERMITS AND INSPECTIONS. E. ACCESS PANELS: OF NFPA 90A SHALL BE TESTED FOR COMPLIANCE WITH THE www.bece.com FULL INTENT AND SCOPE OF THE CONSTRUCTION CONTRACT PRIOR TO FINAL PAYMENT,TURN OVER TO ARCHITECT ALL 39. DUCTWORK: (LOW VELOCITY) 1) REINFORCED,GALVANIZED SHEET METAL WITH AIRTIGHT REQUIREMENTS OF NFPA 90A. DRAWINGS AND SPECIFICATIONS. CERTIFICATES OF COMPLETION. GASKETS RATED FOR PRESSURES AND SERVICE INTENDED. A. FLEXIBLE DUCTWORK SHALL HAVE AN OUTER JACKET OF FIRE MILCOR OR EQUAL. PROVIDE HINGES AND VENTFABRICS, INC. D. ACCEPTANCE TESTS OF FIRE PROTECTION DEVICES IN HVAC 5. PROVIDE A BASE BID WHICH SHALL INCLUDE ONLY SPECIFIED RETARDANT POLYETHYLENE VAPOR BARRIER MATERIAL, UNIFORM VENTLOCK LATCHES. EQUIPMENT OR EQUIPMENT LISTED AS EQUIVALENT. NO SUBSTITUTIONS 21. WARRANTY THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND LAYER OF FIBERGLASS INSULATION, HIGH-STRENGTH GALVANIZED 2) DUCT ACCESS PANELS FOR HAND ENTRY ONLY: NO.90 SASH SYSTEMS SHALL,AS FAR AS PRACTICABLE, BE PERFORMED UNDER WORKMANSHIP. THE WARRANTY SHALL BE FOR A PERIOD OF ONE YEAR NORMAL OPERATING CONDITIONS. FOR THE LISTED EQUIPMENT SHALL BE ALLOWED IN THE BASE BID. AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY STEEL HELIX ENCAPSULATED IN REINFORCED"RIP STOP"ALUMINUM TYPE LATCH. MINIMUM SIZE: 18"X 18". REMEDIED WITHOUT COST TO THE OWNER. LAMINATE INTERIOR CORE, UL LISTED AND LABELED, CLASS 1 AIR 3) DUCT AND PLENUM ACCESS DOORS FOR BODY ENTRY: NO.310 57. FIRE PROTECTION DESIGN/BUILD REQUIREMENTS: A. THE MANUFACTURER OF EQUIPMENT OR MATERIALS FIRST NAMED DUCT. WORKING PRESSURE RATING: POSITIVE 6", NEGATIVE 4". LATCH,OPERABLE FROM BOTH SIDES OF DOOR. MINIMUM SIZE: ON THE DRAWINGS IS THE BASIS OF DESIGN. OTHER FLEXMASTER TYPE 5 OR EQUIVALENT. SUBMIT SAMPLES TO 18"X 18". 22. SUBMIT RECORD DOCUMENTS TO ARCHITECT. DOCUMENTS SHALL A. REVISE AND EXTEND AN EXISTING AUTOMATIC SPRINKLER SYSTEM. L � ON Y FACTURERS LISTED ARE CONSIDERED GENERAL EQUIVALENTS INCLUDE ALL ADDENDUM ITEMS, CHANGE ORDERS,ALTERATIONS, DETERMINE EQUIVALENCE. 4) PANERS NCE OTHER SECTIONS FOR CEILING/WALL ACCESS COMPLETE DRAWINGS, SPECIFICATIONS,AND DETAILS SHALL BE R��`�� `��e�`�. REROUTINGS, ETC. SUBMITTED BY THE FIRE SPRINKLER DESIGN-BUILD CONTRACTOR. ' � �'�d B. FLEXIBLE CONNECTION: EQUIVALENT TO VENTFAB, FIREPROOF B. COORDINATION OF GENERAL EQUIVALENTS AND SUBSTITUTIONS: ti,� /,y,� ��fi�� WHERE CONTRACT DOCUMENTS PERMIT SELECTION FROM SEVERAL 23. SYSTEMS SHALL BE COMPLETE,OPERABLE,AND READY FOR GLASS CLOTH, 10"W.C. RATED. F. BACKDRAFT DAMPERS: PROVIDE COUNTER WEIGHT TYPE (��I�. GENERAL EQUIVALENTS,OR WHERE SUBSTITUTIONS ARE CONTINUOUS OPERATION PRIOR TO ACCEPTANCE BY THE OWNER. BACKDRAFT DAMPERS IN ALL DUCTS OPENING TO THE OUTSIDE B. THE FIRE SPRINKLER CONTRACTOR SHALL SERVE AS THE ENGINEER ; �,��H� ' AUTHORIZED,COORDINATE CLEARANCE AND OTHER INTERFACE C. ROUND DUCT: SPIRAL SEAM, GALVANIZED STEEL. DIE STAMPED OR RUSKIN MODEL CBS-7 OR APPROVED EQUAL. OF RECORD FOR ALL WORK PERFORMED UNDER THIS DIVISION. IF ; {t� F � , , REQUIRED BY THE AUTHORITY HAVING JURISDICTION,(AHJ)SUBMIT -r3�� '� �j 6 ` F:�.�'1° 5 GORE ELBOWS. `SNAP-LOCK', LONGITUDINAL SEAM DUCT,OR REQUIREMENTS WITH MECHANICAL AND OTHER WORK. 24. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. PERFORM AT A COMPLETE FIRE SPRINKLER SYSTEM SHOP DRAWINGS AND Q�cA,'�-�__ ADJUSTABLE FITTINGS ARE ACCEPTABLE ON INDIVIDUAL 43. SUPPORT PIPE WITH ROD AND CLEVIS, RING HANGERS,TRAPEZE,OR -- " �' . MINIMUM ALL CODE REQUIRED TESTS OR SYSTEMS. IF TESTS OF WORK HYDRAULIC CALCULATIONS, GENERATED BY CONTRACTOR. SHOP _�`�������� 1) PROVIDE NECESSARY ADDITIONAL ITEMS SO THAT SELECTED ARE DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY GRILLE/DIFFUSER RUNOUTS ONLY. CLAMPS. NO PIPE TAPE OR STRAPPING ALLOWED. ALL HANGERS SHALL DRAWINGS SHALL BE A MINIMUM 1/8"SCALE,AND SHALL SHOW - OR SUBSTITUTED ITEM OPERATES EQUIVALENT TO THE BASIS AT NO ADDITIONAL COST TO OWNER. BE SIZED FOR OD OF INSULATION, IF ANY. PROTECT INSULATED LINES DEVICE AND APPLIANCE LOCATIONS, BUILDING BACKGROUND OF DESIGN AND PROPERLY FITS IN THE AVAILABLE SPACE D. LINER: WITH 20 GA SHEET METAL SHIELDS AND PROVIDE CALCIUM SILICATE INFORMATION, ROOM OCCUPANCY DESCRIPTIONS, DOOR SWINGS, ALLOCATED FOR THE BASIS OF DESIGN. INSULATION INSERTS FOR ALL INSULATED PIPING. MAINTAIN VAPOR FIRE RATINGS AND FIRE PROTECTION SYSTEM LAYOUT AND DETAILS. 25. ALL MATERIALS AND/OR EQUIPMENT SHALL BE HANDLED AND INSTALLED BARRIER ON ALL COLD LINES. ISOLATE BARE COPPER LINES FROM AS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 1) LINE ALL SUPPLY,OUTSIDE AIR, RETURN AIR DUCTS, EXHAUST SHOP DRAWINGS AND HYDRAULIC CALCULATIONS SHALL BE SEALED 2) PROVIDE ALL FEATURES WHICH ARE STANDARD ON THE BASIS HANGERS WITH VIBRASORB OR EQUIVALENT, COPPER COATED AIR RISERS,AND MAKE UP AIR RISERS WITH 1", 1.5 LB/CF, BLACK BY A PROFESSIONAL ENGINEER OR NICET III LICENSED TECHNICIAN -, � OF DESIGN PLUS ANY SPECIFIED OPTIONS. MATTE COATED INSULATING DUCT LINER. HANGERS ARE NOT SUFFICIENT,WRAPPING PIPE WITH TAPE NOT REGISTERED IN THE STATE OF COLORADO. SUBMIT SHOP Issue/Revisions Date IVO. I 26. SUBMIT ALL MECHANICAL DIVISION SHOP DRAWING AND PRODUCT DATA ACCEPTABLE. DRAWINGS AND HYDRAULIC CALCULATIONS TO THE BUILDING AND 3) BE RESPONSIBLE FOR ASSURING THAT PIPING,CONDUIT, DUCT, AT ONE TIME. SUBMITTAL SHALL BE BOUND AND INDEXED IN A NEAT AND FIRE DEPARTMENTS AND OBTAIN THEIR APPROVAL BEFORE FLUE,AND OTHER SERVICE LOCATIONS FOR GENERAL ORDERLY MANNER. PARTIAL SUBMITTALS WILL BE REJECTED. 2) INSULATION CONDUCTIVITY VALUE NOT EXCEEDING 0.27 SUBMITTALS SHALL INCLUDE, BUT NOT BE LIMITED TO: EQUIPMENT, BTU*IN/(HR*FT^2�F). 44. REFER TO PLUMBING FIXTURE CONNECTIONS SCHEDULE FOR PIPE SIZES SUBMISSION TO THE ARCHITECT. EQUIVALENTS OR SUBSTITUTIONS DO NOT CAUSE ACCESS, TO INDIVIDUAL PLUMBING FIXTURES. SERVICE,OR OPERATIONAL DIFFICULTIES ANY GREATER THAT FIXTURES, INSULATION, DIFFUSERS,WATER HEATERS, PUMPS, FANS, PIPING,VALVES,CONTROLS,AND FIRE PROTECTION. 3 LINER SHALL BE COATED AND SEALED AND SHALL MEET ASTM C. WHERE REQUIRED BY THE AHJ,ALL NEW SPRINKLER HEADS SHOULD WOULD BE ENCOUNTERED WITH THE BASE DESIGN. � 45. PROVIDE SHOCK ARRESTERS AT ALL DOMESTIC HOT AND COLD WATER HAVE THE CONNECTING MAIN AND BRANCH PIPE SIZES SHOWN. C1071. BRANCHES SERVING FIXTURES AND EQUIPMENT WITH QUICK CLOSING 6. INASMUCH AS DESIGN FOR REMODEL AND/OR REHABILITATION 27. FAILURE TO ORDER, OR RELEASE ORDER FOR MATERIALS AND/OR VALVES. SUCH FIXTURES AND EQUIPMENT INCLUDES FLUSH VALVE REQUIRES THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE 4) MATERIAL SHALL MEET ALL REQUIREMENTS OF NFPA-90. WATER CLOSETS, DISHWASHERS,AND ICE MACHINES. SHOCK 1) SHOW THE CONNECTING MAIN AND BRANCH PIPE SIZES FOR ALL CONDITIONS,AND BECAUSE SOME OF THESE ASSUMPTIONS CANNOT BE ALTERNATE MATERIALS, EQUIPMENT,OR INSTALLATION METHODS. ARRESTERS SHALL BE CONSTRUCTED WITH A PISTON IN A SEALED NEW, RELOCATED,AND EXISTING SPRINKLER HEADS. VERIFIED WITHOUT DESTROYING OTHERWISE ADEQUATE OR 5) INSTALL WITH ADHESIVE AND WELDED PINS IN ACCORDANCE COPPER TUBE CHAMBER,AND APPROVED FOR INSTALLATION WITHIN SERVICEABLE PORTIONS OF THE BUILDING,THE ENGINEER CANNOT 2g. REPAIR ALL ACCIDENTAL OR INTENTIONAL DAMAGE TO MATCH EXISTING WITH SMACNA"HVAC DUCT CONSTRUCTION STANDARDS". WALLS WITHOUT ACCESS PANELS. SIOUX CHIEF OR EQUIVALENT. 2) CONFORM TO LIGHT HAZARD OCCUPANCY REQUIREMENTS OF ASSURE THE OWNER OR THE CONTRACTOR THAT THE PROFESSIONAL CONSTRUCTION WITH NO NOTICEABLE DIFFERENCE IN CONTINUITY, BELLOWS TYPE NOT ACCEPTABLE. NFPA 13. CONSULTING SERVICES HEREIN ENCOMPASS ALL CONTINGENCIES. APPEARANCE OR FUNCTION. FIELD COORDINATION DURING CONSTRUCTION IS IMPERATIVE. MAKE 6) EXTERNALLY WRAP ALL ROUND SUPPLY AIR DUCTS WITH REASONABLE ALLOWANCES FOR UNSEEN CONDITIONS. FLEXIBLE GLASS FIBER,ANSI/ASTM C612;0.002 INCH FOIL SCRIM 46. DOMESTIC HOT AND COLD PIPING INSIDE BUILDING--NON-BURIED LINES, 3) PROVIDE FLOW TEST INDICATING STATIC AND RESIDUAL 29. TEMPORARY HEAT SHALL BE FURNISHED BY THE GENERAL FACING. TYPE"L"HARD COPPER WATER TUBE,WROUGHT COPPER FITTINGS AND PRESSURED DEVELOPED UNDER FIRE FLOW CONDITIONS AS 7. THE BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONTRACTOR. USE OF THE PERMANENT HEATING SYSTEM WILL NOT BE NO LEAD 95-5 SOLDER. REQUIRED BY AHJ. ALLOWED. CONSTRUCTION. CONTINUED OPERATION OF THE FACILITY SHALL NOT 7) ALL RAW EDGES OF INSULATION SHALL BE NEATLY TRIMMED BE HINDERED BY THIS WORK. ACCOUNT FOR ALL ADDITIONAL COSTS AND SEALED WITH MASTIC. 47. COPPER PIPE VALVES AND SPECIALTIES E. EXTEND THE EXISTING SPRINKLER SYSTEM, RELOCATE EXISTING Project Information WHICH MAY BE INCURRED DUE TO THE DIFFICULTY OF WORKING OVER 30. COORDINATE ALL PENETRATIONS OF THE FLOOR SLAB PRIOR TO AND ADD NEW SPRINKLER HEADS IN ACCORDANCE WITH NFPA 13, AND AROUND EMPLOYEES, FURNITURE, EQUIPMENT, ETC.;AND DUE TO COMMENCING WORK. UTILIZE X-RAY AND VISUAL INVESTIGATION OF E. DUCTWORK: G60 GALVANIZED SHEET STEEL; LOCK FORMING A. GATE VALVES-BRONZE,CLASS 125,200 LB.W.O.G. ALL APPLICABLE CODES AND ORDINANCES AND PROJECT THE HOURS OF THE DAY IN WHICH AN AREA MAY BE ACCESSIBLE WHEN EXISTING CONDITIONS AS REQUIRED PRIOR TO DRILLING OR CUTTING. QUALITY; CONSTRUCTED TO THE LATEST EDITION OF SMACNA"HVAC REQUIREMENTS TO COMPLETE THE NEW WORK. COMPILING HIS BID. COORDINATE ALL NEW PENETRATIONS WITH OTHER DIVISIONS OF THE B. BALL VALVES-BRONZE, CLASS 125,600 LB.W.O.G. DUCT CONSTRUCTION STANDARDS';+/-1"WC PRESSURE C. CHECK VALVES-BRONZE,CLASS 125,200 LB.W.O.G. WORK. ALL CONTRACTORS ARE INDIVIDUALLY RESPONSIBLE FOR ALL F. SYSTEM SHALL BE INSTALLED COMPLETE AND OPERATIONAL, CLASSIFICATION,SEAL CLASS"C°;WITH GALVANIZED STEEL Vail 8. BE RESPONSIBLE TO FIELD VERIFY EXISTING EQUIPMENT OR DUCTWORK PENETRATIONS REQUIRED BY THEIR DIVISIONS. FASTENERS,ANCHORS,ANGLES, STRAPS, ETC. D. BALANCING VALVES-125 PSI W.P. FOR 250 DEGREE FARENHEIGHT INCLUDING WATER FLOW INDICATOR, CONNECTIONS TO EXISTING U REMAINING TO BE CONNECTED TO NEW SYSTEMS. PROVIDE DUCTWORK, SERVICE TIGHT SHUTOFF,TOUR AND ANDERSON STA,ARMSTRONG ALARM, DRAIN PIPING, IDENTIFICATION SIGNS, ETC. Q PIPING, CONTROLS, DIFFUSERS, ETC.,AS REQUIRED TO RESTORE CBV,GERAND, OR FLOWSET, B&G CIRCUIT SETTER. � 31. FIRE STOPPING REQUIREMENT. PENETRATIONS THROUGH RATED F. SEAL ALL SEAMS(LONGITUDINAL AND TRANSVERSE)AIRTIGHT WITH E. DIRECT UNIONS: FURNISH AND INSTALL A DIELECTRIC UNION AT U CONTINUITY OF SYSTEM(S), OR TO MAKE NEW WORK MEET EXISTING WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF G. WORK SHALL BE PERFORMED BY A QUALIFIED FIRE SPRINKLER Valley � CONDITIONS,WHETHER INDICATED OR NOT. PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES WHEN UNITED MCGILL"UNI-GRIP"UL LISTED,WATER BASED, EACH CONNECTION BETWEEN DISSIMILAR METALS. INSTALLER WITH A MINIMUM OF FIVE 5 YEARS EXPERIENCE IN � NON-HARDENING, ELASTIC SEALANT OR EQUIVALENT. TAPE NOT � � ca SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC SIMILAR INSTALLATIONS. • 9. IF NOT SPECIFICALLY DEFINED IN THESE CONSTRUCTION DOCUMENTS, ALLOWED. M���C�� � FOR FIRE STOPS ASTM-E-814. ACCEPTABLE MATERIALS INCLUDE: DOW 48. MATERIALS;SOIL,WASTE,AND VENT PIPING(INSIDE BUILDING) w MATERIALS AND/OR EQUIPMENT SHALL BE IDENTIFIED BY THE CORNING RTV FIRE STOP FOAM FOR BARE PIPE, METAL CONDUIT,AND � , �� H. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO AND � SUBCONTRACTOR WITH SUFFICIENT TIME TO ALLOW SELECTION, ELECTRICAL CABLE;3M FIRE DAM 150 CAULK FOR BARE PIPE, METAL 40. PROVIDE /4 GALVANIZED MESH SCREEN ON ALL COMBUSTION AIR PURCHASE,AND DELIVERY TO MAINTAIN CONSTRUCTION SCHEDULE. DUCTS OR OPENINGS,AND ALL OPEN END RETURN AND EXHAUST A. LINES ABOVE GROUND: STANDARD WEIGHT, CAST IRON SOIL PIPE, DURING INSTALLATION. C enter o CONDUIT,AND BUILDING CONSTRUCTION GAPS; 3M CP-25 CAULK AND AND FITTINGS. HUB AND SPIGOT WITH NEOPRENE GASKETS,OR NO N FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, PLASTIC PIPE OR DUCTS. HUB WITH STANDARD CLAMPS. UP THROUGH 2-1/2"MAY BE � 10. PROVIDE MECHANICAL DEMOLITION AS REQUIRED. REFER TO CONDUIT,AND ELECTRICAL CABLE. SUBMIT UL LISTED APPLICATION I. PROVIDE AN EXTRA STOCK OF SIX(6)SPRINKLER HEADS,THREE(3) o STANDARD WEIGHT, GALVANIZED STEEL PIPE WITH BLACK, U ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT DATA FOR EACH TYPE OF PENETRATION ENCOUNTERED. 41. ALL DUCTWORK DIMENSIONS ARE OUTSIDE SHEET METAL DIMENSIONS. WROUGHT IRON DRAIN FITTINGS,OR DWV COPPER TUBE WITH DWV OF EACH TYPE,AND A SPRINKLER WRENCH. SPRINKLER HEADS � OF DEMOLITION REQUIRED. VISIT SITE PRIOR TO BID TO DETERMINE DUCT LINER HAS BEEN ACCOUNTED FOR IN RECTANGULAR DUCTWORK. FITTINGS AND 95-5 NO LEAD SOLDER. SHALL MATCH EXISTING IN ADJACENT AREAS. g EXTENT OF WORK INVOLVED. EXISTING FIXTURES, MECHANICAL 32. DUCTS, PIPING,AND CONDUITS PENETRATING THROUGH ROOF SHALL EQUIPMENT, ETC., BEING REMOVED SHALL BE RETURNED TO THE � HAVE ROOF FLASHING COMPATIBLE WITH THE ROOFING SYSTEM. SEE 42. DUCTWORK NOTES: 49. GAS PIPING:SCHEDULE 40 BLACK STEEL PIPE, 150 LB. MALLEABLE IRON OWNER. DISPOSE OF ALL REMOVED PIPING, DUCTWORK, ETC. UNLESS ARCHITECTURAL DRAWINGS. IN THE ABSENCE OF ANY OTHER Va i I S u m m it � NOTED OTHERWISE. SCREWED FITTINGS ON ABOVE GROUND PIPE,WELDED FITTINGS WITH � REQUIREMENTS, PROVIDE SHEET LEAD TYPE FLASHING FOR PLUMBING A. DIFFUSER NECK SIZE IS SAME AS FLEXIBLE DUCT SIZE. ALL PIPING COATED AND WRAPPED ON BURIED PIPE. � 11. ALL DUCTWORK, DIFFUSERS, PIPING, FIXTURES,AND EQUIPMENT SHOWN VENTS IN BUILT-UP ROOFS,TALL CONE WITH EPDM BOOT FOR PIPE AND O rth o paed i cs m IN LIGHT LINE WEIGHT IS EXISTING, NEW INDICATED BY HEAVIER LINE CONDUIT IN SINGLE PLY MEMBRANE ROOFS,AND CURBED ROOF g. UNLESS OTHERWISE NOTED,ALL CHANGES IN DIRECTION SHALL BE 50. GAS VALVES: NON-LUBRICATED BALL STYLE VALVE WITH RESILIENT � WEIGHT, EXCEPT WHERE NOTED. PIPES, DUCTWORK, EQUIPMENT, ETC. PENETRATIONS IN ALL TYPES OF ROOF. INSTALLATION SHALL BE MADE WITH RADIUS ELBOWS WITH RADIUS TO CENTERLINE EQUAL SEATS,AND ADJUSTABLE GLAND PACKING NUT,AGA AND UL LISTED FOR � TO BE REMOVED,ARE SHOWN HATCHED. WATERTIGHT. TO 1.5 DUCT WIDTH. NATURAL GAS SERVICE. c a 12. OFFSET PIPING, DUCTWORK, ETC.AS NECESSARY TO ACCOMMODATE 33. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR ALL CEILING US Bank Building � 1) WHERE REQUIRED FOR SPACE CONSTRAINTS, PROVIDE SQUARE 51. SUPPORT EACH FAN BY MASON INDUSTRIES OR EQUIVALENT SPRING � STRUCTURE, BEAMS,COLUMNS,AND EXISTING SYSTEMS. PENETRATIONS AND AIR DEVICE LOCATIONS. THROAT ELBOWS WITH SINGLE WIDTH(NON-AIRFOIL)TURNING TYPE VIBRATION ISOLATORS. SUIt@ ZO6 -° VANES. 0 13. ALL EXISTING SUPPORT RODS AND STRAPS NOW SUPPORTING DUCTS, 34. COORDINATE ARCHITECTURAL, MECHANICAL, FIRE PROTECTION, 52. INDOOR PIPING INSULATION-INSULATE ALL NEW DOMESTIC WATER, � PIPES, ELECTRICAL CONDUIT, ETC.THAT ARE REMOVED TO ALLOW ELECTRICAL,AND INTERIOR DESIGN DRAWINGS PRIOR TO INSTALLATION. 2) FOR DUCT DEPTHS OF 36"OR LESS, PROVIDE MANUFACTURED DOMESTIC HOT WATER,AND DOMESTIC HOT WATER RECIRCULATION 108 South Frontage Road �r ROOM FOR INSTALLATION OF NEW EQUIPMENT SHALL BE RELOCATED SINGLE WIDTH(NON-AIRFOIL)TURNING VANES,WITH SPACING IN PIPING WITH UL APPROVED,WHITE,ALL SERVICE,MINERAL FIBER, Vail Colorado 81657 M AND REINSTALLED,OR REPLACED IF DAMAGED. � � 35. CAREFULLY VERIFY ELECTRICAL SERVICE VOLTAGE AND PHASE ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS SNAP-ON, PIPE INSULATION. INSULATE FITTINGS WITH MINERAL FIBER � 14. ALL"CAPPED"SANITARY AND VENT LINES SHALL BE RECONNECTED OR AVAILABLE. FOR"STANDARD SPACING". USE DOUBLE THICKNESS BLADES BLANKET INSULATION AND PRE-MOLDED PVC COVERS. ALL MATERIALS U FOR DUCT DEPTHS GREATER THAN 36". USE NO TRAILING SHALL HAVE A SMOKE DEVELOPED RATING OF 50 OR LESS AND A FLAME -� RE-ROUTED AS NECESSARY TO PREVENT"DEAD-ENDS"IN THE PIPING. w ALL PIPING SHALL DRAIN TO ACTIVE SANITARY WASTE LINES AND ALL 36. MOUNT ALL STATS AT 48"AFF IN"ACCESSIBLE"AREAS,4'6"AFF IN OTHER EDGES. SPREAD RATING OF 25 OR LESS. PROVIDE CALCIUM SILICATE THERMAL Sheet Information U BRANCHES WITH TRAPS SHALL BE ADEQUATELY VENTED. AREAS, UNLESS NOTED OTHERWISE. COORDINATE LOCATION WITH INSERT AT HANGERS AND SUPPORTS. INSULATION SHALL PASS m WALL FINISH,AND TO AVOID CASEWORK, FURNITURE, DOOR SWINGS, C. ALL FLEXIBLE DUCTS SHALL NOT EXCEED EIGHT FEET IN LENGTH. UNINTERRUPTED THROUGH HANGERS. VAPOR BARRIERS SHALL BE Sheet Title: � 15. CAP ALL DEMOLISHED AND ABANDONED DUCT TAKE-OFFS AT TRUNK HEAT SOURCES,AND EXTERIOR WALLS. NOTIFY ENGINEER OF ANY CONTINUOUS,AND SEALED WITH"NON-BREATHING"VAPOR BARRIER CONFLICTS PRIOR TO BEGINNING THERMOSTAT INSTALLATION. MASTIC ON PIPING OPERATING AT TEMPERATURES BELOW AMBIENT. U D. RETURN AIR PLENUM: THE HVAC SYSTEM WILL USE THE SPACE M E C HAN I CAL � ALL RAW EDGES OF INSULATION SHALL BE NEATLY TRIMMED AND �� SEALED WITH MASTIC. � = SPECIFICATIONS � � � � � U � N Q O L L O �� CD/PERMIT 03/03/2014 � �, Sheet Number: .� > � � M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ DEMOLITION FLAG NOTES : �� . � � ODEMO AND REMOVE(E)SUPPLY AIR DIFFUSER AND ■ . ■ SUPPLY DUCT BACK TO POINT OF CONNECTION AT ■ . ASSOCIATED MAIN DUCT. ROUTING OF(E)SUPPLY - - DUCTWORK NOT FULLY REPRESENTED IN THESE ■ . ■ . DEMO DRAWINGS. ■ 2O DEMO AND REMOVE(E)RETURN AIR GRILLE AND ■ ■ ■ ■ CEILING RADIATION DAMPER. i � 3O (E)PNEUMATIC THERMOSTAT TO BE REMOVED. � i � � j � � � O (E)VAV BOX TO BE REMOVED.APPROXIMATE DAV I S i I I LOCATION OF(E)VAV BOX. CONTRACTOR TO FIELD � O O O O VERIFY EXACT LOCATION AND NUMBER OF VAV i � BOXES SERVING SCOPE OF WORK. PARTN E RSH I P � 2 i j 2 2 � � � O WITIHO NNT MOUNO ED HERMOS AT TYP OARD i 0 , 0 , 0 � ARCH ITECTS � �� '� i i � � � 6� (E)BASEBOARD THERMOSTAT TO BE REMOVED. � � �� �i�i � � Denver �301 Blake Street, Suite 100 i i � i i i r � O7 DEMO AND REMOVE(E)SUPPLY AIR DIFFUSER AND I Denver, CO 80205 303.861.8555 i ' �i i i SUPPLY DUCT BACK TO(E)VAV TERMINAL. � � � i �i I i �� � Vail 0225 Main Street, Unit C101 � � � i I I i �J 8O DISCONNECT AND DEMO SUPPLY AIR FROM(E) I Edwards, CO 81632 970.926.8960 � i i il I I i � ERV-1 TO SUPPLY DIFFUSER CONNECTION POINT. � � ' i i i CAP BRANCH TAP AT MAIN DUCT AND PREPARE FOR I i i i O� O� �i I RECONNECTION. , Consultant � � � � F '� , �i i � � i � i i 1 i I i ��� i I � i \ _ � �, � �� �, i '� A B EAU DI N _ ' ' ' ', ; NOTES : � Cj ANZE � / OO 9O/ � � 1. NOTIFY ENGINEER IMMEDIATELY OF ANY i � I DISCREPANCIES OF WFORMATION REPRESENTED IN Consulting Engineers, Inc. ii THE DOCUMENTS VERSUS WHAT IS FOUND IN THE Vail: (970) 949-6108 COPYRIGHT2014 � � I I FIELD. Denver: (303) 278-3820 project No:8739.41 I i Fort Collins: (970) 221-5691 I i � Albuquerque: (505)323-9070 � � 2. COORDINATE PATCHING AND REPAIRS OF WALLS Jackson: (307)739-3944 WITH ARCHITECT. www.bece.com \ � ___________.__.____________.__.___, _______________.__.________'_ ___— I 3. OTHERBUILDINGSYSTEMSEXISTWITHINTHESPACE � ' ---------------- ---------- -------------------------� i i ' ii � r THAT ARE NOT REPRESENTED ON THESE DRAWINGS. � � �� �! I MODIFICATIONS TO THESE SYSTEMS ARE NOT ii � � � n � � � � ; � i � q � � _ ANTICIPATED. � ii IVI 1O 1O I� i i � � n � 4. (E)WASTE SYSTEM SERVING SPACE IS LOCATED IN ' — THE CEILING OF THE SPACE BELOW. '�-_, ' i ' J _ r � ' � ,-n i� � � � � i � �� II � �� i � i ° r � ,' � i i 1 - - - 5. REMOVE ALL MECHANICAL ITEMS INDICATED. � � �� � c � i , � i i i ��__-- -. �� � �� � i �i ' � � I�.. 6. TEMPORARY SEAL OR CAP PIPING FOR CONNECTION .'� � � � � �O i � �.._----- �_. , � i ' � � � �� ' - - LATER. �� �'�in� _� i i � ------------ --- / I � �. i � � � � ,� � � � � � N�PIPING �MOED CW/DHW TO PREVENT DEAD ENDS "� � �'��� �,� O � , � _ ' �A N I I 0 � '���;�. � ������ � � i � � � 8. CAP ALL DEMOED SUPPLY BRANCHES AT {�� �s�'� -____-- --------- ------ � O � i i Oi ASSOCIATED SUPPLY MAIN. +�1��9�� -------------------� � - 3 i , J �`� � � ' �o� 9. (E)BUILDING PNEUMATIC SYSTEM TO BE - - , � --� - �-- ----- � � � , % � � - --- '-------- � � ' U RECONFIGURED AS REQUIRED TO ACCOMMODATE �-- � � � � � �,, , ,' � �� REMOVAL OF(E)PNEUMATIC THERMOSTATS SHOWN � �� ����� i � IC�" � � HEREIN. � i � i i � � I —, � ��--'� �� �� OO �� i i W O M E � � 10. DISCONNECT, DEMO,AND REMOVE ALL(E) ISSU@�ReVISIO1lS Dat@ IVO. I i i i � - � � i J= CW/HW,HWC AND W/V SERVING SPACE BACK TO � � i � ! � ASSOCIATED MAINS. �� � � � ; _ _ ii � — _`� -- ' � ----------- � ii i � / �� �� � � _ __ � �' -------------- - - O � � � � � 1 � - ��� � i ` �� � �� 4� i E OPEN RETURN AIR DUCT I ---� � ) � i � --� � � TO PLENUM TO REMAIN. -- ----------- � i � j --- 7 -� i�� i ��. / I � � � � � i i � � � � i i i i ��� � ------------------ ------- ---------------- ---- ---------------------- y _ _._.. _ _ — -------------------------------------------------r----- � II II i I �E�24��� ' �� I�i I�i li �i i OI -_ �I i — 1 � � � _ I Project Information , , , ; ; ; O I � �_� �_ �_�c � � ��CJ , O � � � � i O/ i' i' ' f � U � � � 2 i � � � � i � Q O � � � Vall � ; , , , / U J � I I � � alley � , � � 'I � � ' � / _ i �. � � � � � Medical , � a N ,— / � ,�- enter o , � � U � L � c� G � VC------- � � ------- - ------- -, � � - --- -- - ------- -� ------- � . m.} � DISCONNECT AND SALVAGE(E) i i i i T i i � V�I I S U�1 1 1 I` I I I � BDD I I I I � THERMOSTAT FOR REINSTALLATION. � 2 � �______ ___ _____�____ , , �� � � Orthopaedics m � � , , �� � � � O I I _J \,... .I.L I I . --- � II I I .i DISCONNECTAND DEMO DOWNSTREAM �i � \�-�' i i a RETURN DUCT ASSOCIATED WITH ERV-1; � � CAP AND PREPARE FOR RECONNECTION. � / i i�i �� US Bank Building o /� � ` � Suite 206 � � o -, � O 108 South Frontage Road � I Vail, Colorado 81657 M i►i iii ' � � % ERV-1 � I U ��� ��� / � w -,�- ----„--_ ��� � Os � �Os � ! - - , , �� ' � Sheet Information m __1--�---�---u--� ___� � 2 I ' �.� i � ������ ������'r � Sheet Title: � ' BDD � > MECHANICAL � � � O' � B� � - - DEMO PLAN � / �; � . - - � � � ~ O � � ' � O N � �, � � U � I I IJ �` \ � / / I I / 1 L I I � ° '� � CD/PERMIT 03/03/2014 �� . � I % � �� �--� �� T _ fi. � L � O � \ � v _ � Sheet Number: ' i i � MECHANICAL DEMO PLAN M � � SCALE: 1/4" = 1'-0" � U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ NOTES : �� . � � 1. RE:SHEET M3.0 FOR HVAC AND PLUMBING ■ . ■ DIAGRAMS. ■ . DUCT RETURN THRU PARTITION WALL TO - 2. AVOID ROUTING DUCTWORK OVER ELECTRICAL ■ . ■ . - ADJACENT CEILING SPACE SO PLENUM ABOVE ADMIN WORK IS NOT CONSIDERED ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. R.A. PLENUM. CLEARANCES. COORDINATE ROUTINGS WITH DIV.26 ■ ■ ■ ■■ CONTRACTOR. � 3. PROVIDE FLEXIBLE DUCT CONNECTIONS TO ALL MOTORIZED EQUIPMENT. Q �� DAVI S 4. ALL DAMPERS AND ACTUATORS SHALL BE INSTALLED ABOVE DROP-IN CEILINGS IN HALLS AT a c� c� Q Q � ACCESSIBLE LOCATIONS; MINIMIZE INSTALLATION PARTN E RSH I P `� c� AI�MIN � �2K � c� OVER HARD-LID CEILINGS WHEN POSSIBLE. � ��3� p � � � � 5. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS A R C H I T E C T S Q N � � X � X � N � '- � � � / POSSIBLE IN THE CEILING SPACE. UTILIZE OPEN } WEB JOIST SPACE WHEN POSSIBLE, ESPECIALLY � � � � WHERE CROSSING OTHER PIPES, DUCTS,AND r _ r _ 8„� � ELECTRICAL. Denver I De�nv B1 CO 80205 5303.86�1.8555 WP,ITING 6. CEILING COORDINATION OF ALL MEP SYSTEMS /��EXH � � r _ I 202 _ �� � I (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, Vail 0225 Main Street, Unit C101 V �sX�Z m r 1 \J FIRE PROTECTION, ETC.)MUST BE COMPLETED BY I Edwards, CO 81632 970.926.8960 � / i� � THE CONTRACTOR PRIOR TO THE START OF ANY 8"0 � � INSTALLATIONS. m Consultant FIELD COORDWATE EXH FAN I ° \� I 7. THE SPACE ABOVE THE CEILING IS BEING UTILIZED LOCATION WITH REQUIRED � ���� � � - AS A RETURN AIR PLENUM.ALL RETURN GRILLES SUPPORTS FOR X-RAY SHALL BE PROVIDED WITH SOUND BOOTS AND A EQUIPMENT. T DIRECT PATH TO THE AIR HANDLING SYSTEM — m RETURN DUCT, OPEN TO PLENUM,TO MAINTAIN MAXIMUM AIR VELOCITY OF 500 FPM.WHERE FULL EF-2 ¢ X T HEIGHT WALLS ARE INSTALLED AND THE RETURN B EAU DI N — � N � m I I� i AIR PATH IS COMPROMISED,THE SOUND BOOT � - �- CORRI DOI� SHALL EXTEND THROUGH THE WALL OR TRANSFER �ANZE � v 2�5 A a � N ZO��� Consulting Engineers, Inc. AIR DUCTS SHALL BE PROVIDED. 24x2 8. PROVIDE MANUAL BALANCE DAMPER AT EACH Vail: (970) 949-6108 COPYRIGHT 2014 c� SUPPLY DIFFUSER BRANCH. Denver: (303) 278-3820 ProjectNo:8739.41 � I ��, � N AlbuCuelrnue: �970) 221-5691 9. INSTALL VAV BOXES TO ALLOW FOR REQUIRED q 9 (505)323-9070 m �� _ Jackson: (307)739-3944 � � 6" � 100 � ACCESS AND CLEARANCES TO CONTROLS, HEATING www.bece.com � �/-� 2�5 I -- 12x12�=/ � COIL, ETC. A � � � lI 24x�4y�v X 0 2 N � u � 10. IF(E)RTUS WITHIN SCOPE OF WORK DO NOT 20�� — � ��� XZq A � CURRENTLY HAVE A SMOKE DETECTOR IN THE � — ���� RETURN AIR PATH, CONTRACTOR TO PROVIDE IN � — � _ FB-4 M � � - EACH. � / �m RI::���TIO�I � 11. EXISTING RETURN AIR GRILLES FEATURE CEILING - � 201 _ ��, RADIATION DAMPERS. TO MAINTAIN CONSISTENCY � � � - TO ANY RATED ASSEMBLY STRATEGY THAT IS � � �� I / UNCLEAR TO THE DESIGN TEAM,CEILING ��_-- -. �� - I �� m - ��- �-� q / _� RADIATION DAMPERS ARE BEING INCLUDED ON ,- ► � ( �-�d m 16 a� T 12 o T � NEW RETURN GRILLES. � ' � ��''��: FB-3 I ' ����� ' o m — l ; � , o, �f 12"� R.A. � / • F e� �� .��: �j°��C, J H �- � � �A N I I 0 � �� � �. � �` L — A (- __ 24x24 � � 24x24 m o� 300 � FB-5 s i� � ��'u�„������� ' - ' � 24X2�� � � - - - SCOPE NOTES : � � � � � , , �,� ��`'[ �"m II � �_ ( 1 1. OUTDOOR CONDENSING UNITS CU-1 ASSOCIATED 21 1 � FB-2 �2�M 60 q ��� WITH I.T.COOLING LOAD TO BE LOCATED ON ROOF �� 12x12 DIRECTLY ABOVE I.T. CLOSET; NOT SHOWN ON —, � � \' Q � � � I � I W�J M E I �I PLAN. FIELD ROUTE REFRIGERANT LINE SET, Issue/Revisions Date IVO. I ifl io io 8 FXAM c., EXAM E� AM � �/I\� L MAINTAINING DIRECT MOST PATH. �� �1� � � � _ 209 I Ot3 � - i � � 2. ROUTE PUMPED CONDENSATE FROM WALL HUNG 200 � � _ � � � FC-1 INDIRECTLY TO NEAREST SINK TAILPIECE. B � 24x24 1 — U O 6�Oq I 6"� � �_ � 12x12 N � r� � c°� � HA!= I �16 � CONNECT(N)SUPPLY AIR 200 � � r �— Q =. � °' DAMPERS TO(E)MAIN,TYP. 24x24 �� � � � - - � �� I�' ( � 9 9 9 9 �XAM ; ' — --7I � � � (E)24 � � %V � �—� I/ \I — — - _ � � � � „ -� ��+ �'° � � �_� � � �_�� � ���, � Project Information a �60 /� � 6 � � ,V I 2 o N � 12x12 9 � � � o � T � r U A 275 1 � 10"0 r Vail 24x24 / � � � � 6"a � EX I� U 10" � � � � �� ��_ alley � , _ � � �- — P/PA coA � ° Q • � 5 T , 2�4 � , �_ �� 22 , N Medlcal \ � � A 12"� — „a� ,, N � � ���5� Center N / � � 219 ° ADMIN FB-1 R��r� I~ALL 6��° CORRIDO�Z � 24x24 �%� � �'I�j I I 230 � � - �� - � `, . . � I T Y ail Summit � EF-1 BDD ;� o� °�� T ' Ortho aedics m 12x12 12x12 � � � SERVER RA 100 � � �- 222 B � H L� � 24x� 24x24 a � 3 FC-1 e e oPEN oF��cE o N US Bank Building � ��� � � �% Suite 206 0 � ' 108 South Frontage Road M R�A g � Vail, Colorado 81657 % I 24x24 I Q CONNECT(N)SUPPLY MAIN TO III ERV-1 III � _� U (E)VAV TERMINAL BOX,TYP.2. ` w h o R -,T, � � - � Sheet Information � �� � RA Sheet Title: � � � B I� � 24x12 H VAC P LAN � CONNECT(N)OSA AND EXH BRANCH � � , � �c DUCTS TO(E)ERV DUCTWORK. Bpp �R�A� � S��I OrZ GE Q � Bop � �� , G ?" �, BDD— — � � � .r � � L � OFFICE I OF ICE � � m � � J � � � _ � 125 ,--� 24x24 � �� Q �U � 0 200 A 24x24 = 24x24 � p ° N ° � �� _ � T T CD/PERMIT 03/03/2014 �, � Sheet Number: SUP TS FOR X-RAY I > EQUIP ENT. + � �' HVAC PLAN � � . � SCALE: 1/8" = 1'-0" a� .a � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ NOTES : ■■ - 1. RE: SHEET M3.0 FOR HVAC AND PLUMBING . ■ DIAGRAMS. ■ . ■ 2. REFER TO THE PLUMBING FIXTURE CONNECTION ■ . SCHEDULE FOR PIPE SIZES TO INDIVIDUAL ■ . ■ . - FIXTURES. ■ 3. NOT ALL REQUIRED CLEANOUTS ARE ■ ■ ■ ■ NECESSARILY SHOWN ON THESE PLANS. PROVIDE �� CLEANOUTS ON WASTE,VENT AND STORM PIPING I ' ' AS REQUIRED BY CODE AND FOR REASONABLE i �I j MAINTENANCE BASED ON ACTUAL FIELD DAV I S I- — -� INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER. ADMIN WORK � 4. INSTALL THERMOSTATIC MIXING VALVES,ASSE PARTN E RSH I P � - I I n 1070 LISTED,AT EACH PUBLIC HANDWASHING ' ` �o; � � WH 1, ROUT€�P�RV EL EF � LAVATORY/SINK.SIZE TO MATCH HW PIPE SIZE. TO NEAREST(E)FL o A R C H I T E C T S DRAIN OR SINK TAI PI CE. 5. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES.COORDINATE ROUTINGS WITH DIV. Denver 2301 Blake Street, Suite 100 26 CONTRACTOR. Denver, CO 80205 303.861.8555 WAITING `��`� 6. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALL 0225 Main Street, Unit C101 1-1/4"HW AND 3/4"H C TO RVE �I � Vail MULTI-SPECIALTY CLINIC A OVE. � � `�� MOTORIZED EQUIPMENT. Edwards, CO 81632 970.926.8960 COORDINATE CONNECTIQfy POINT IN THE FIELD.; CW 1�C5 7. ROUTE DOMESTIC HOT WATER RECIRC TO WITHIN CLINIC SPACE NOT 10 FEET OF ALL HOT WATER FIXTURES. COIISUItallt , _ � ., FROM THIS LEVEUS, @PE� F _ � WORK. — 8. PEX PIPING SHALL NOT BE ALLOWED TO - i 1" � � ` PENETRATE FIRE BARRIERS WHERE FIRE �____i ir ,i \ 1-1/2" �- ' 1 I CAULKING IS REQUIRED. LOCATE SHUT OFF VALVES FOR �i �i �� 9. ALL VALVES SHALL BE INSTALLED ABOVE DROP IN EAU DI N MAINTENANCE OVER HALLS,TYP// ___� i i � , , � � i - - -' �� CEILINGS IN HALLS AT ACCESSIBLE LOCATIONS; B � P6 i � MINIMIZE VALVES OVER HARD-LID CEILINGS WHEN � i > > POSSIBLE. G ANZE � , I � - c�i�r�i�o'��1 - � �---� n n n � � 200 � � � 10. ALL PIPING SHALL BE ROUTED AS HIGH AS Consulting Engineers, Inc. i i P� � POSSIBLE IN THE CEILING SPACE. UTILIZE OPEN Vail: (970) 949-6108 COPYRIGHT 2014 j � i P5 WEB JOIST SPACE WHEN POSSIBLE, ESPECIALLY Denver. (303) 278-3820 Project No:8739.41 / �----�-------i- � � WHERE CROSSING OTHER PIPES, DUCTS,AND FortCollins: (9�0) 221-5e91 I I I I C :� Jaoksonr ue: �307)739-3944 /� � ELECTRICAL. I i I i �� � 1 i \ www.bece.com 5 5 23-9 7 � � � � � � � 11. CEILING COORDINATION OF ALL MEP SYSTEMS L————�————————�—————————————J � i i TC�T - ' - - (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, EXAM ��— - FIRE PROTECTION, ETC.)MUST BE COMPLETED BY F 20a i i X �RAY � M � THE CONTRACTOR PRIOR TO THE START OF ANY i i - - � i i I ��N � � ^\ ,I INSTALLATIONS. i i M�r I V � L______J — �� - 12. THE SPACE ABOVE THE CEILING IS BEING UTILIZED � � 2��C��TION � � I _ � � AS A RETURN AIR PLENUM. i_�-� BALANCE TO 0.5 GP 2 �- 13. (E)G SERVICE IS OBSERVED TO BE LOW PRESSURE � � ' �: P1 C� �� 3/4" / � � � � I� � �� 1-1/4" / (<0.5 PSI)SYSTEM. ��__� �_ ��� �� - � ( � � LANCE TO 0.5 G . 1-1/4" — � -� 14. WASTE LINES IN CEILING OF SPACE BELOW WILL � •� � �'�fid ` BALANCE TO 0.5 GPM. � � � �� � REQUIRE FLOORS TO BE SAW CUT AND PATCHED �I �r,� BALANCE TO 1.5 GPM. I ' ^ AFTER PIPING IS INSTALLED. � ; ���fl' �� m m co � • � --- �� � 4 � . � ��2 HA! I. � = � I � '�� '� I� 15. STOP VALVES SHALL BE PROVIDED FOR EACH • �a��,ae��, 3/4" - --�—-- - ( 1 �� ��'�. � � � � �07 � I / C�NNLCF(N)1�'/2"� O(E)CW MAIN OF PLUMBING FIXTURE. ��c,� — � - —3/4"— I -- I �-- I EQUAL OR LARGER SI . FIELD DETERMINE -C`� '��'"���� s�f��',�:�- i CONNECTION POINT. TIFY ENGINEER IF(E) 16. WASTE ROUTED IN CEILING OF LEVEL BELOW. � P� I � �� E ENT THAN ASSUMED. �� � ° � - - IV U f�S E � � _� � 2�i� � FXAIV� � � �� % ` W O M �_ �! Issue/Revisions Date No.� , �� � � � 1 E, M � �XAM � EXAM � � 09 1 208 I � � \ 20 _ W W - _ 4" ^ _ - - / � � � � � M I � � � _ � , � -� �-�,�i_i_ , � � � � � � � _ -,� i P�PA � � C P1 e � CONNECT(N)4"W TO(E)W MAIN OF EQUAL OR LARGER SIZE AND CONNECT(N)2-1/2"V TO(E) _. i � � 2" � � �� �' V �-���" ` �� VENT SYSTEM OF EQUAL OR LARGER SIZE. 3/4"-1�— FIELD DETERMINE CONNECTION POINTAS(E) , P� � EXAM PIPING WITHIN SHAFT IS MOSTLY CONCEALED. � I P1 I I 218 OT ENGII�ER', F(E)W O V CATIO A � � �FFER T HAN ,SSUMED. \ � U U U U � -0_ � —L Project Information � � I � � � � �_�C � � � � �� I � N I M � � il �. ' Va U � � � _ EXAM \ J \ I ,� � =� _ --_ Valley � �� � P �A „z�� � � �� � � M i 1 � �4 �; ed ca � _ _ _ ° P� NURS` Center � � ; u o � � ADMIN �,�A_� � � � 213 � 2�1 � CORR D0=2 � � � 230 . � � � � � � � C I.—• — ��__ . — �U � � ..�� . � Vail Summit ;� T �� L � � Ortho aedics m � � � � p � � � sERVER � � , � �' P4 HA�� 222 �� �� 223 a oPEN o��icE � US Bank Building � P3 ' i 2z9 � � Suite 206 ° � ��� 108 South Frontage Road � Vail, Colorado 81657 M � W � Q —� U w � � � � � � _ R Sheet Information U VALVES TO BE NORMALLY CLOSED � Sheet Title: m SERVING CW/HW BRANCH TO �° FUTURE KITCHEN GROUP; LOCATE � � �� U VALVES TO PREVENT DEAD-ENDS c-cn IN BRANCHES. P L U M B I N G � BRFAI�: STORAGE 2�6 '�� P LAN � OFFICE OFFICE � � 227 228 U � � � 3/4"CW/HW,2"V CAPPED AND 2"W U P O � Q- WITH WALL C�EANOUT FOR 0 -� EXTENSION TO FUTURE KITCHEN � O GROUP. i �� � CD/PERMIT 03/03/2014 � � Sheet Number: .� > � �' PLUMBING PLAN � � . � SCALE: 1/4" = 1'-0" .a � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ SUPPORT FROM OVERHEAD USE DUCT SEALANT OR � STRUCTURE. GASKETED FITTING ON HIGH — ■ . ■ - VELOCITY DUCT. �__ ■ . ■ COLD WATER SUPPLY. ■ . 22 GA.SHEET METAL BOOT CONICAL SPIN-IN FITTING W/ I ■ . ■ . - 3'-0" MANUAL DAMPER, HANDLE, HOT WATER TO � ■ W/1"DUCT INSULATION. &LOCK NUT. FIXTURES. ( S HOT WATER CIRC. ■ ■ ■ ■ MINIMUM SIZE= 12x24. FROM FIXTURES. I FLEX DUCT. � PIPE RELIEF VALVE o � DIAPHRAGM TYPE NO TURNING � INDIRECT TO FLOOR EXPANSION TANK. VANES. � DRAIN. EXTROL ST-12-C. D��I � � <,Y I � �� ! � DOMESTIC HW �J PARTN E RSH I P RECIRC PUMP. Q ELECTRIC WATER � A R C H I T E C T S WORM DRIVE S.S.CLAMP. HEATER. USE SPIN-IN FITTING Denver 2301 Blake Street, Suite 100 FOR ROUND DUCT. � NOTE: IDenver, CO 80205 303.861.8555 � DIAGRAM FOR LOW&HIGH VELOCITY RETURN GRILLE DUCTWORK EXCEPT UPSTREAM OF Vail 0225 Main Street, Unit C101 VAV BOXES.OMIT DAMPER&FLEX Edwards, CO 81632 970.926.8960 DUCT UPSTREAM OF VAV BOXES. - Consultant RETURN AIR GRILLE ROUND DUCT SOUND BOOT DIAGRAM TAKE-OFF DIAGRAM DOMESTIC WATER HEATER DIAGRAM NO SCALE O NO SCALE O NO SCALE ( ELECTRIC ) O B EAUDIN ADJUSTABLE GRADE CLEANOUT AND ACCESS ENCLOSURE WITH ANCHOR FLANGE, G ANZE / HEAVY DUTY TOP,AND VANDAL PROOF FASTENERS,ZURN, Z-1400-HD-KBRASS AIR FLOW 1/4 OF"W"OR 6" CLEANOUT PLUG W/COUNTER SUNK HEAD. Consulting Engineers, Inc. ~ MINIMUM. Vail: (9�0) 94s-61o8 COPYRIGHT2014 ADJUSTABLE CLEANOUT 16"CONC. PAD TROWEL Denver: (303) 278-3820 ProectNo:8739.41 FLOOR LINE AND ACCESS COVER ZURN SMOOTH&EDGE. Fort Collins: (9�0) 221-5s91 � RIGID DUCT NO ZB-1400.TOP OF COVER TO Albuquerque: (505)323-9070 FLEX. MIN.36" 45-ENTRY OR BE FLUSH W/TOP OF FLOOR. wwwsbece.com �307)739-3944 LATERAL TEE. FINISHED GRADE STRAIGHT DUCT. —� r � � o � CLEARANCE FOR ����o �� °�° 6 �o�p a °� � D FOR CONTROLS. �p D °�, �D �p D a D � — - 45° I I BEARING. 1/8 C.I. BEND � i i ��� I���� BALANCE OF PIPING SAME 1/8 C.I. BEND / � �%/ i��.�\` �Y AS CLEANOUT TO GRADE. � � � / � ( H C.I.WASTE LINE. ���-- ���� AIR TERMINAL. � �� �' � � LGTH TO SUIT. - ► � ( �-�d � � FLOOR CLEANOUT (FCO) �,•� �'�fi� ACCESS FOR � SLOPE DN @ 1/4"/L.F. �I���� �. PROVIDE FOLLOWING OPTIONS AS APPROPRIATE . HEATER. CARPET MARKER-FOR CARPETED AREAS. �� � { [� MIN.4'-0"STRAIGHT SQUARE TOP-FOR CERAMIC TILE OR WASTE LINE '��` `�'�ee��, SINGLE BLADE DAMPER SIMILAR SQUARE PATTERN FLOOR. � � �6 „ � DUCT, FULL OUTLET � �A''-__ S I Z E, P R I O R T O A N Y IF H<8"OPP O SED BLADE FLA SHIN G CLAMP-FOR AB OVE GRADE ���,������� . ELBOW OR DAMPER IF H>=8" WATER PROOFED AREAS. _ TAKE-OFF. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. SEAL AIRTIGHT AROUND ENTIRE TAKE-OFF. o CLEANOUT TO GRADE (COTG) Issue/Revisions Date No.� ELECTRIC HEAT 45 DUCT TAKE- AIR TERMINAL DIAGRAM OFF DIAGRAM CLEANOUT DIAGRAMS NO SCALE OH NO SCALE O NO SCALE O EXTERIOR DUCT INSULATION. MAY EXTEND AS A CONICAL SPIN-IN FITTING WITH SUPPORT AS REQUIRED WASTE OR VENT. MANUAL VOLUME DAMPER. FOR MIN RADIUS SPECIFIED. CHROME WALLCOVER INSULATED SUPPLY DUCT AS AND SCREW. NOTED IN SPECIFICATIONS. INSULATED ACOUSTIC FLEX DUCT. PLUGGED TEE WITH CLEANOUT. MINIMUM � RADIUS> 1.5 �x�� x�.�; � x FLEX DUCT DIAMETER. x <^ >%9>%9>'><� wa��. Project Information x � � �� O / � U ;_� � :� _� � � � all � SHEET METAL o 0 o g v v o J � � o o v o 0 � STRAP. ° �° � o °�° � � alley E � SHEET METAL o v o 1/8 C.I. BEND. � �n SHIELD. �^����� w � BALANCE OF PIPING o S.S.WORM DRIVE — - N CLAMP. SAME AS CLEANOUT � SQUARE TO ROUND ADAPTER CEILING DIFFUSER TO GRADE. Center 0 AS REQUIRED. � WALL CLEANOUT � TYPICAL DIFFUSER CONNECTION DIAGRAM DIAGRAM U � NO SCALE O NO SCALE O Va i I S u m m it U ;� Orthopaedics m � � � a US Bank Building � Suite 206 � 0 M � 108 South Frontage Road � Vail, Colorado 81657 M � W � Q -� w Sheet Information U m Sheet Title: � � = MECHANICAL � .� � DIAGRAMS _ � � � � � U � N Q O L L O �� CD/PERMIT 03/03/2014 � �, Sheet Number: .� > � � M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ GENERAL CONTROLS NOTES : CONTROLS LEGEND ■ LINE VOLTAGE POWER REQUIREMENTS FOR CONTROLS SYSTEM HAVE BEEN ■ • ■ - ESTIMATED ON PLAN; CONTROLS CONTRACTOR TO FIELD COORDINATE WITH DIV.26 AFMS AIRFLOW MEASURING STATION ■ . ■ CONTRACTOR FOR REQUIREMENTS. DIV. 26 CONTRACTOR TO INCLUDE CONTROLS ■ . POWER IN BASE BID. AI ANALOG INPUT TO BCS ■ . - CONTROLS CONTRACTOR SHALL BE RESPONSIBLE FOR WIRING AND INSTALLING ALL ■ . DEVICES AND AIR TUBING REQUIRED FOR A FULLY FUNCTIONAL CONTROL SYSTEM AO ANALOG OUTPUT FROM BCS ■ ■ ■ ■■ FOR THIS PROJECT, REGARDLESS OF VOLTAGE. IF THE CONTRACTOR CANNOT SELF PERFORM WORK REQUIRING LINE VOLTAGE THEN THE CONTRACTOR SHALL gl BINARY INPUT TO BCS COORDINATE WITH AND COMPENSATE THE ELECTRICAL CONTRACTOR AS REQUIRED. CONTROLS CONTRACTOR SHALL COORDINATE WITH EQUIPMENT SUPPLIERS TO BO BINARY OUTPUT FROM BCS DAV I S ENSURE THAT ALL DEVICES ARE COMPATIBLE WITH THE EXISTING CONTROLS SYSTEM. CO2 CARBON DIOXIDE SENSOR PA RT N E RS H I P CO CARBON MONOXIDE SENSOR A R C H I T E C T S CS CURRENT SWITCH Denver 2301 Blake Street, Suite 100 1 1 �P EQUIPMENT MANUFACTURER'S CONTROL Denver, CO 80205 303.861.8555 PANEL 1 1 Vail 0225 Main Street, Unit C101 DM DAMPER MOTOR Edwards, CO 81632 970.926.8960 ELECTRIC WATER HEATER SHALL OPERATE VIA �PT DIFFERENTIAL PRESSURE TRANSDUCER MS MANUFACTURER'S INTERNAL CONTROLS. COIISUItallt DPS DIFFERENTIAL PRESSURE SWITCH WATER HEATER TANK TEMPERATURE SHALL BE SET TO 120 DEG F. UPON A CALL FOR HEAT MS FROM A TANK MOUNTED AQUASTAT,THE EPO EMERGENCY POWER OFF ELECTRIC HEATING ELEMENT SHALL BE B EAU DI N TSTAT ENERGIZED. CONVERSELY,WHEN A CALL FOR ^�F FLOW SENSOR HEAT IS NO LONGER PRESENT,THE HEATING ELEMENT SHALL DE-ENERGIZE. G ANZE / EXHAUST FAN SERVING THE X-RAY ROOM SHALL BE CONTROLLED BY INDIVIDUAL SPACE MOUNTED COOLING THERMOSTAT SET AT 78°F(ADJ). DURING OCCUPIED HOURS,AN AQUASTAT IN FS FLOW SWITCH Consulting Engineers, Inc. THE HOT WATER CIRC PIPING SHALL CYCLE EXHAUST FANS SERVING RESTROOM SHALL BE ENABLED DURING OCCUPIED Vail: (970) 949-6108 COPYRIGHT 2014 UPON A RISE IN SPACE TEMPERATURE ABOVE SETPOINT PLUS DIFFERENTIAL, DHW RECIRCULATION TO MAINTAIN A DHW EXHAUST FANS SHALL ENABLE.CONVERSELY, UPON A DECREASE IN SPACE HOURS AND SHALL BE DISABLED DURING UNOCCUPIED HOURS. FRZ FREEZSTAT Denver: (303) 278-3820 Project No:8739.41 RECIRCULATION TEMPERATURE OF 110°F FortCollins: (970) 221-5691 TEMPERATURE BELOW SETPOINT PLUS DIFFERENTIAL, EXHAUST FANS SHALL (ADJ.). DURING UNOCCUPIED HOURS,THE DHW Albuquerque: (505)323-9070 DISABLE. RECIRC PUMP SHALL BE OFF. HE HUMIDITY SENSOR Jackson: (307)739-3944 www.bece.com MS MOTOR STARTER EXHAUST FAN ELECTRIC WATER HEATER EXHAUST FAN RLY RELAY THERMOSTAT CONTROL SCHEMATIC CONTROL SCHEMATIC OCCUPIED UNOCCUPIED SCHEMATIC 2 Q SENSOR 3 SCALE: NO SCALE 4 SCALE: NO SCALE SCALE: NONE SMK SMOKE DETECTOR � � �� ��`:_-� . �e�` . J �� '.�`d � SWITCH ��•' ;�, �''��: ��•��� , TE TEMPERATURE SENSOR : {�+�'� .rs�`A '� �° � „ °�` TEMP � �'�-_ ' �` SENSOR ���'���,�;�,.�� TSTAT THERMOSTAT VFD VARIABLE FREQUENCY DRIVE Issue/Revisions Date No.� SPACE MOUNTED STAT SCHEDULING: THE ROOM TEMPERATURE SETPOINT SHALL BE SCHEDULED THROUGH THE OPERATOR �� FROM AHU SA � WORKSTATION SUCH THAT HEATING ROOM TEMPERATURE SETPOINT AND COOLING ROOM TEMPERATURE SETPOINT ARE SET UP AND SET BACK RESPECTIVELY DURING - - UNOCCUPIED MODES. A THERMOSTAT MOUNTED TIMED OVERRIDE BUTTON SHALL DM ALLOW ROOM OCCUPANTS TO OVERRIDE THE VAV BOX INTO AN OCCUPIED MODE FOR TE A SET TIME DURATION SHOULD OCCUPANTS DESIRE TO USE THE SPACE DURING UNOCCUPIED TIMES. THE RESPECTIVE AIR HANLDING UNIT SHALL BE OPERATIONAL WHENEVER VAV BOX IS IN OCCUPIED MODE. �� FROM PLENUM CONTROL THE AIRFLOW PRESSURE TRANDUCER SHALL INDICATE TO THE UNIT MOUNTED DDC CONTROLLER MEASURED AIRFLOW. THE DDC CONTROLLER SHALL MODULATE THE VAV BOX DAMPER TO MAINTAIN AIRFLOW AT SETPOINT. AIRFLOW SETPOINT SHALL BE RESET BASED ON THE DIFFERENCE BETWEEN SPACE TEMPERATURE AND SPACE SETPOINT. UPON A RISE IN SPACE TEMPERATURE ABOVE SETPOINT AIRFLOW SHALL PROGRAMMABLE, PNEUMATIC RLY MODULATE TO THE MAXIMUM SETPIONT. UPON A FALL IN SPACE TEMPERATURE ROOM MOUNTED T-STAT BELOW SPACE TEMPERATURE SETPOINT AIRFLOW SHALL MODULATE TO THE MINIMUM Project Information SETPOINT. SHOULD SPACE TEMPERATURE REMAIN BELOW SPACE SETPOINT PLUS DIFFERENTIAL THE FIRST STAGE OF HEATING SHALL BE TO ENERGIZE THE PARALLEL VAV BOX FAN TO INTRODUCE WARM PLENUM AIR INTO THE AIRSTREAM AND THEN SUBSEQUENTLY ENERGIZE THE ELECTRIC HEAT COIL. OUTDOOR CONDENSING UNIT AND INDOOR FAN COIL Rs UNIT SHALL OPERATE IN ACCORDANCE WITH THE � A SPACE MOUNTED TEMPERATURE SENSOR SHALL INCORPORATE A WARMER/COOLER MANUFACTURER'S PACKAGED CONTROL SYSTEM TO V all U ADJUSTMENT ALLOWING ZONE OCCUPANTS TO BIAS THE SPACE TEMPERATURE OUTDOOR CONDENSING UNIT R� MAINTAIN SPACE TEMPERATURE SETPOINTS. SPACE � SETPOINT BY A FIXED AMOUNT IN EITHER DIRECTION. TEMPERATURE SETPOINT SHALL BE INITIALLY SET AT Vall� J 70°F. FEATURES m SPACE TEMPERATURE SHALL BE TRENDED HOURLY SPACE TEMPERATURE THERMOSTAT SHALL BE SEVEN M � � � SPACE TEMPERATURES 5 DEGREES OR MORE ABOVE OR BELOW SETPOINT SHALL � DAY PROGRAMMABLE TYPE TO ALLOW OCCUPIED AND ed ca � (E)PNEUMATIC CONTROLS ALARM � UNOCCUPIED TIME PERIODS.WHEN IN OCCUPIED � MODE, SYSTEM SHALL CYCLE TO MAINTAIN OCCUPIED o SPACE TEMPERATURE SETPOINT. WHEN IN UNOCCUPIED MODE, SYSTEM IS OFF OR SHALL CYCLE enter c-i 0 � INDOOR FAN COIL UNIT SETPOINT. U L � � SPACE MOUNTED THE OUTDOOR COMPRESSORS ARE CYCLED ON AND � THERMOSTAT. OFF TO MEET COOLING ZONE DEMANDS. � Vail Summit � � PARALLEL FAN POWERED VAV WITH ELECTRIC REHEAT Orthopaedics T � . -� SCALE: NONE SERVER ROOM AIR CONDITIONING � a UNIT CONTROL SCHEMATIC US Bank Building � � Suite 206 � SCALE: NONE � M � 108 South Frontage Road � Vail, Colorado 81657 M � W � Q -� w Sheet Information U m Sheet Title: � �j (E)RTU AND AHU SYSTEMS SERVING SPACE � SHALL HAVE EXISTING CONTROLS STRATEGY M EC HAN I CAL �� REMAIN AS IS. WHEN IN OCCUPIED MODE, ii UNITS ARE DELIVERING SUPPLY AIR, � DISCHARGE TEMPERATURE BASED ON MANUAL C O N T RO L S c SELECTION OF HEATING OR COOLING MODE. °� WHEN IN UNOCCUPIED MODE, UNITS ONLY � � PROVIDE SUPPLY AIR TO MAINTAIN SPACE � SETBACK TEMPERATURES. a� Q 0 � L O �� E RTU AHU SYSTEMS CD/PERMIT 03/03/2014 � NTRO SCHEMATIC Sheet Number: � j SCALE: NO SCALE � � M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ COMMUNICATION SYMBOLS LIGHTING FIXTURE SYMBOLS POWER SYMBOLS ■■ • � � � TELEPHONE WALL OUTLET Q RECESSED LIGHTING FIXTURE Q- SINGLE RECEPTACLE ■ . ■ ■ . N DOUBLE TELEPHONE WALL OUTLET Q� DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE � DUPLEX RECEPTACLE ■ . ■ . - B TELEPHONE FLOOR OUTLET � SURFACE MOUNTED LIGHT C� DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER ■ ■ D DATA WALL OUTLET � PENDANT MOUNTED LIGHT � DOUBLE DUPLEX RECEPTACLE ■ ■ ■ � DATA WALL OUTLET Q-) WALL MOUNTED LIGHT � GFCI DUPLEX RECEPTACLE � DATA FLOOR OUTLET Q-I WALL MOUNTED UP-LIGHT � DUPLEX RECEPTACLE; HALF SWITCHED DAV I � COMBO PHONE/DATA OUTLET M MONO-POINT LIGHTING FIXTURE � ISOLATED GROUND DUPLEX RECEPTACLE S I� � DOUBLE COMBO PHONE/DATA OUTLET II RECESSED STEP LIGHT � MULTI-OUTLET PLUG STRIP PA RT N E RS H I P � COMBO PHONE/DATA FLOOR OUTLET I-O-I FLUORESCENT STRIP LIGHT � FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE OF� VOICE/DATA/FIBER OUTLET � WALL MOUNTED LINEAR FLUORESCENT LIGHT � FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE A R C H I T E C T S POS� POINT OF SALE(POS)OUTLET 0 RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER � FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED ATM � AUTOMATED TELLER MACHINE(ATM)STATION � � FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT � FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM Denver I2301 Blake Street, Suite 100 Denver, CO 80205 303.861.8555 pp� PUBLIC PAYPHONE OUTLET � CEILING MOUNTED EXIT SIGN W/FACES&ARROWS AS SHOWN � WALL MOUNTED SPECIAL OUTLET AS NOTED Vail 0225 Main Street, Unit C101 E� ELEVATOR PHONE OUTLET � WALL MOUNTED EXIT SIGN W/FACES&ARROWS AS SHOWN � SPECIAL OUTLET AS NOTED Edwards, CO 81632 970.926.8960 � POWER/TELECOM POLE � EMERGENCY LIGHTS JQ JUNCTION BOX � CLOCK WALL OUTLET �-o EXTERIOR POLE MOUNTED LIGHT JQ-I WALL MOUNTED JUNCTION BOX Consultant � CLOCK CEILING OUTLET �O EXTERIOR POST(BOLLARD)MOUNTED LIGHT J� FLOOR MOUNTED JUNCTION BOX TT TIME TONE GENERATOR e DIVISION 15 EQUIPMENT POWER CONNECTION OC -) CALLINSWITCH LIGHTING CONTROL SYMBOLS TS TIMERSWITCH M IC MASTER INTERCOM STATION $ SWITCH �I FUSED DISCONNECT B EAU DI N IC INTERCOM STATION S3 THREE-WAY SWITCH � NON FUSED DISCONNECT G ANZE / �A AMPLIFIER S4 FOUR-WAY SWITCH � MOTOR STARTER Consulting Engineers, Inc. J DOOR JAMB SWITCH Vail: (970) 949-6108 COPYRIGHT 2014 � CHIME S �B ENCLOSED CIRCUIT BREAKER Denver: (303) 278-3820 ProjectNo:8739.41 Fort Collins: (970) 221-5691 �B BUZZER SK KEY SWITCH PB PULL BOX Albuquerque: (505)323-9070 Jackson: (307)739-3944 OB BELL SV VARIABLE SPEED SWITCH Q PUSH BUTTON www.bece.com �' GROUNDING BUSBAR ST THERMAL OVERLOAD SWITCH Tc TIME CLOCK � WIRELESS LAN(WI-FI)ACCESS POINT Q DIMMER � PHOTO-CELL �3 THREE-WAY DIMMER Q TRANSFORMER LV LOW VOLTAGE SWITCH G PANELBOARD OR LOADCENTER A B B R E V I AT I 0 N S g� WALL OCCUPANCY SENSOR/SWITCH � CONTACTOR AFC-ABOVE FINISHED CEILING o� SMALL ROOM OCCUPANCY SENSOR � ELECTRIC MOTOR �y �f� ���,. ...... �� AFF-ABOVE FINISHED FLOOR o� LARGE ROOM OCCUPANCY SENSOR g METER �� ;• . ����' ., �` C3 :E �: AFG-ABOVE FINISHED GRADE o� CORRIDOR OCCUPANCY SENSOR Q THERMOSTAT � � AHJ-AUTHORITY HAVING JURISDICTION DL DAYLIGHT PHOTO SENSOR ATS AUTOMATIC TRANSFER SWITCH � . � + � . AL -ALUMINUM —� CIRCUIT HOMERUN �'Q�•.,`•�,^�i4•�,.����r� AP -ACCESS POINT CONDUIT RUN �'�S'�{)��+�,��� AWG-AMERICAN WIRE GAUGE A U D I OV I S U A L SY M B O LS --- CONDUIT RUN BELOW GRADE BFG-BELOW FINISH GRADE TV WALL MOUNTED TELEVISION OUTLET � CONDUIT UP BMS-BUILDING MANAGEMENT SYSTEM TV CEILING MOUNTED TELEVISION OUTLET —� CONDUIT DOWN Issue/Revisions Date IVO. I C -CONDUIT TV FLOOR MOUNTED TELEVISION OUTLET g SWITCH CATV-COMMUNITY(CABLE)ANTENNA TELEVISION SYSTEM �V-� WALL MOUNTED AUDIOVISUAL OUTLET ST THERMAL OVERLOAD SWITCH CCTV-CLOSED CIRCUIT TELEVISION �V CEILING MOUNTED AUDIOVISUAL OUTLET S� VARIABLE SPEED SWITCH CKT-CIRCUIT AV FLOOR MOUNTED AUDIOVISUAL OUTLET SK KEY SWITCH CPU-CENTRAL PROCESSING UNIT OS CEILING MOUNTED SPEAKER CT -CURRENT TRANSFORMER OS -� WALL MOUNTED SPEAKER 0 N E—LI N E D I AG RA M SY M B 0 LS DISP-GARBAGE DISPOSAL VQ-I VOLUME CONTROL —� DISCONNECT SWITCH DW -DISHWASHER Q FLOOR MOUNTED MICROPHONE OUTLET � FUSE EM -EMERGENCY �M -) WALL MOUNTED MICROPHONE OUTLET fL CIRCUIT BREAKER EWC-ELECTRIC WATER COOLER CT CONTROL TOUCH PAD � CURRENT TRANSFORMER (E) -EXISTING � CONTROL KEYPAD �� POTENTIAL TRANSFORMER Project Information FA -FIRE ALARM � CEILING MOUNTED PROJECTOR O METER FACP-FIRE ALARM CONTROL PANEL �� WALL MOUNTED PROJECTOR VO VOLT-METER FBO-FURNISHED BY OTHERS —� SPEAKER ZONE HOMERUN OA AMP-METER Q GC -GENERAL CONTRACTOR SS SURGE SUPPRESSION DEVICE Vail �j GFI -GROUND FAULT CIRCUIT INTERRUPTER � SELECTOR SWITCH J � GRD-GROUND �F GROUND FAULT PROTECTION alley n N � N IAW-IN ACCORDANCE WITH sT � SHUNT TRIP � ' IC -INTERMEDIATE CROSS-CONNECT -� �- NORMALLY OPEN CONTACT � Center ° IDF-INTERMEDIATE DISTRIBUTION FRAME � NORMALLY CLOSED CONTACT N o IG -ISOLATED GROUND = GROUND � � IR -INFRARED O COLD WATER GROUND CONNECTION c� � LAN-LOCAL AREA NETWORK g BUILDING STEEL GROUND CONNECTION � � MDF-MAIN DISTRIBUTION FRAME Va i I S u m m it � � NIC-NOT IN CONTRACT T Orthopaedics � NL -NIGHT LIGHT ISSUE LOG c NTS-NOT TO SCALE a / US Bank Building � PA -PUBLICADDRESS ELECTRICAL SHEET INDEX � / -� OC -ON CENTER Suite 206 0 �° REF-REFRIGERATOR �t�,'� 108 South Frontage Road � TTB-TELEVISION TERMINAL BOARD � Val�, Colorado 81657 Q TVSS-TRANSIENT VOLTAGE SURGE SUPPRESSOR # TITLE oQ�� Q UG -UNDERGROUND � —� w E0.0 ELECTRICAL COVER SHEET � Sheet Information U UNO-UNLESS NOTED OTHERWISE � E0.1 ELECTRICAL SPECIFICATIONS �/ _ _I�___ � V -VOLT E1.0 ELECTRICAL POWER PLAN �/ I I I I I Sheet Title: �j E2.0 LIGHTWG PLAN �/ I I I I I � W -WATT E3.0 ELECTRICAL ONE-LINE DIAGRAM �/ __I. I __I. I _ E L E CT R I CAL �� WAN-WIDE AREA NETWORK � E3.1 ELECTRICAL DIAGRAMS �/ __I. __I. I � WLAN-WIRELESS LOCAL AREA NETWORK I I I I I C OV E R S H E ET c °� WP -WEATHER PROOF � � � XP -EXPLOSION PROOF � ISSUE LOG KEY: Q- +18"-MOUNTING HEIGHT TO CENTERLINE OF ''ISSUED AS PART OF A SET 0 p DEVICE ABOVE FINISH FLOOR ''NOT PART OF SET � � .� '*' ISSUED FOR INFORMATION ONLY QQ M CD/PERMIT 03/03/2014 E �, Sheet Number: .� > � � M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ DIVISION 16-ELECTRICAL SPECIFICATIONS is specified by a generic spec,(no manufacturer's name listed)no prior review by the Engineer is needed unless specifically called for in L Clean and repair existing materials and equipment,wl�icl�remain or are to be reused. 3.03 COMPATIBILITY these specifications. 2. Panelboards: Clean ex osed surfaces and check ti hmess of electrical connections. Re lace dama ed circuit breakers and rovide A. The Contractor is res onsible for all coordination with the utilit c om an for this ro ect,to insure the insta]lation of electrical services ■ - P g P g P P Y ' P Y P 1 ■ . ■ SF,CTION]6010--GENERAL PROVISIONS: C. Contractor to be responsible for any changes and costs to accommodate any equipment except the first named in the specification. closure plates for vacant positions. Provide typed circuit directory showing revised circuiting arrangement. shall be compatible with the entire project,and to insure that electrical service is installed at a time as to provide necessary electrical PART l- GCNERAL D. Substitutions of Material(Contractor and owner initiated) 3. Luminaries: Remove existing luminaires for cleaning. Use mild detergent to clean all exterior and interior surfaces;rinse with clean power as required to the completed project. Single phase equipment on a three phase distribution system shall be connected to insure as I.O1 PROJECT DESCRIPTION 1. Other items of material and equipment not listed as equivalents may be offered(at the Contractor's option)as substitutions to water and wipe dry. Replace lamps,non-operational ballasts,and broken electrical parts. near a balanced system load as possible. ■ . ■ ■ . A. This project is a remodel of an existing medical office building. The project is approximately 3,000 square feet located in Vail, specified items by submitting it as a separate price with his base bid on the Bidder's letterhead. ■ . ■ - Colorado. 2. Such substitute proposals sl�all not be included under the base bid and must be accompanied by full descriptive data on the proposed SECTION 16100--BASIC MATERIALS AND METHODS SFCTION 16500-L[GHTING � equipment,together with a statement of the cost to be deducted for each item and all deviations from specified items. Highlight all PART 1- GENERAL � 1.02 PROVISIONS PART] - GENERAL(Not Used) � � � � difference from specified equipment. If any such substitutions are to be considered,the Contractor shall submit a list of the 1.01 PROViSIONS A. Work performed under this division of the specifications shall conform to the requirements of Division 1,and the electrical drawings and PART 2- PRODUCTS proposed substitution items within 14 days of award of contract. Late requests for proposed substitutions shall not be accepted by all items hereinafter specified. the Engineer due to scheduling or delivery concems. 2.01 RACGWAYS AND FITTINGS A. Provide all interior and exterior lighting fixtures as shown on the plans and hereinafter specified. All items shall beprovided to make a 1. The drawings and specifications for the electrical work are intended to describe a complete electrical system;omission of minor co�nplete and operable lighting system,including lamps,ballasts,poles,hangers,painting,plaster frames,etc. 3. If substitutions are rejected,Electrical Contractor shall supply base bid item as specified. A. Conduit: items obviously necessary to accomplish the above intent shall not relieve the Contractor from providing same. B. Fixtures shall be as shown in the fixture schedule. Catalog numbers shown are the latest available at the time of design. If discrepancies 2.05 PRODUCT HANDLING 1. Conduits subject to mechanical damage or where otherwise required by code shall be galvanized rigid heavy wall conduit;all other occur between descri tion and catalo number,descri tion will take recedence. 2. Prior to any work being performed under this division examine architectural,shuctural,mechanical,and interior design drawings p � p p A. Use all means necessary to proYect electrical system materials before,during and after installation and to protect the insYalled work and conduit may be electric metallic tubing. D��I S and specifications and if any discrepancies occur between them and the electrica]drawings and specifications,report same to the C. Verify trim,finish and general description of all lighting fixtures through shop drawing approval prior to placing order far fixtures. materials of all other trades. 2. Flexible metallic conduit shall be used where vibration or other reasons do not allow solid connections to motors,equipment,etc. Architect in writing and obtain written instructions for the work. Modify catalog numbers accordingly. B. In the event of damage,immediately make all repairs and replacements necessary to the approval of the Architect at no additional cost to Flex may also be used to fish in existing walls or where required to connection in millwork. The use of flex shall be held to a 3. Electrica]drawings are diagrammatic but shall be followed as closely as actual construction ofthe building will permit. All changes PART 2- PRODUCTS ����� ���� � � from drawings necessary to make the electrical wor]<conform to the building as constructed shall be made without cost to the the Owner. minimum. Where flexible metallic conduit is used in areas subject to moisture,PVGcoated flex(Liquidtight)shall be used. Owner. C. U on com letion of all installations,lam m and testin thorou hl ms ect all ex osed ortions of the electrica]installation and B. Fittings 2.01 INCANDESCENT FIXTURES p p p g g� g Y p p p A. Incandescent fixtures to be complete with lamps,and all necessary accessories to provide for their installation. Provide necessary 4. Coordinate the electrical wark with the General Contractor and be responsible to him for satisfactory progress of same. Coordinate completely remove all exposed labels,soil,markings,and foreign materials. 1. Use compression fittings for all EMT conduit. �R� �"'� ������ blocking or other protection to maintain separation of recessed fixtures from combustible material and building insulation system. All electrical wark with all other trades on the project without cost to the Owner. PART 3- EXECUTION 2.02 WIRE AND CABLE recessed fixtures to have thermal protection device. Provide sloping ceiling adaptors where required to place lamp center line beam 5. Do not scale drawings. Verify dimensions on architectural drawings and in field prior to commencement of work. 3.01 WORKMANSHIP AND COMPLLT[ON OF INSTALLATION A. Voltage range 0 to 24:High conductivity copper,thermo-plastic insulation,300 volt rating. candlepower perpendicular to the working plane. 6. All work and materials covered by drawings and speci6cations shall be subject to review at any time by representatives of the A. Contractor's personnel and subcontractors selected to perform the work shall be well versed and skilled in the trades involved. B. Voltage range 24 to 600:High conductivity copper,moisture-resistant thermo-plastic insulation,600 volt 75°C rating for general use. 2.02 FLUORESCENT FIXTURES D@IlV@i' 2301 BI2k0 Stl"28t, SUlte 100 Architect and Owner. If the Architect or Owner's a ent finds an material or installation that does not conform to these drawin s F r HID fixture and wirin within 3 inche f fl ior ,cent alla,t, wire hall be co er �ninimum 90° rated. iz in i ated are f r �D2i1V21', CD 80205 303.861.8555 S Y g B. Coordinate electrical e ui ment and materials installation with other buildin com onents. o s g s o t es b s s, s pp , C S es d c o q p g p A. Fluorescent fixtures to be complete with lamps,and all necessary accessories to provide for their complete installation. Ballasts to be and specifications,Contractor shall remove the material from the preinises and correct the installation to the satisfaction of the agent. installation in a maximum 30°C ambient Conductor ampacity shall be derated for higher ambient installations. C. Sequence,coordinate,and integrate installations of electrical materials and equipment for efficient flow of the Work. Give particular HPF,CBM/ETL,and U.L.listed,class P. Surface fluorescent fixtures to be mounted on low density combustible ceilings to have a U.L. . 0225 Ma111 Stl'22t Ulllt C101 7. In acceptance or rejection of installed electrical systems,no allowance will be made for lack of skill on the part of the installers. attention to lar e e ui ment re uirin ositionin rior to closin -in the buildin C. Conductors used specifically for equipment or service ground may be bare or have insulation to match circuiUfeeder conductors. listing for such mounting. All lenses to be acrylic prismatic plastic types or as shown in the schedule. V811 g 9 p q g p �p � g� Edwards, CO 81632 970.926.8960 1.03 WORK INCLUD�D D. Any changes or deviations from the drawings and specifications must be accepted in wnting by the Arcl�itecUEngineer. All errors in 2.03 WIRE CONNECTIONS B. Fluorescent ballasts shall be electronic programmed-start type,sound rating A,THD less than 10 percent,ballast factor of.88 or higher A. The electrical system required far this work to indude,but is not necessarily limited to: installation shall be correcYed at tl�e expense of the Contractor. All specialties shall be insYalled as detailed on the drawings. Where A. All elech-ical connections shall be electrically and mecl�anically secure,using the following methods: and power factor of 0.95 or higher. 1. Replace fusible switch to two new circuit breakers in main service switchboard. detail or specific installation requirements are not provided,manufacturer's recommendations shall be followed. 1. Wire size#8 and smaller--pressure type connectors(scotch-lok)or equivalent. 2.03 CMERGCNCY OR NIGHT LIGHTfNG Consu Itant E. Upon completion of work,all equipment and materials shall be installed complete,thoroughly checked,correctly adjusted,and left ready A. Fixtures indicated as being on emergency,or nighY light circuits shall be provided with self-contained battery powered inverter uniY for 2. New feeders to new electrical panel on the 2nd floor. 2. Wire size#6 and larger--mechanical ar compression lugs,Burndy,T&B,Ilsco or equivalent. for intended use or operation. All work shall be thoroughly cleaned and all residue shall be removed from surfaces. Cxterior surfaces of direct mounting in fixture. Provide unit with fully automatic two rate charger,nickel cadmium battery,AC"on"pilot light,and test 3. Complete branch circuit wiring for lighting,motors,receptacles,junction boxes,and similar uses. all material and equipment shall be delivered in a perfect,unblemished condition. B. Wire termination provisions for panelboards,circuit breakers,safery switehes,and all other electrical apparatus shall be listed as suitable switch.Design and wire unit to automaYically transFer to battery supply on loss of normal AC power and to operate 32 watt T8 4. Lighting fixtures,wall switches,occupancy sensors,receptacles and similar items. for 75°C. fluorescent lam with minimum out ut of 600 lumens for minimum 1-1/2 hours. F. Contractor shall provide a complete installation,including all required labor,material,cartage,insurance,permits,and taxes. P P 5. Conduits and boxes for data system. 3.02 PROGRESS OF WORK 2.04 OUTLET BOXCS 2.04 LAMPS A. Outlet boxes shall be:one piece steel,galvanized,Steel City Electric,Appleton Llectric,Raco or approved equivalent. Where NMC or 6. Fire alarm system as required by national,state,and local codes. A. Order the progress of electrical work to conform to the progress of the work of the other trades. Complete the entire installation as soon A. Lamps shall be as shown in tl�e fixture schedule as manufactured by Osram-Sylvania,G.E.,Phillips,or approved equivalent. ENT is used,plastic boxes are acceptable. � ������ 1.04 CODfiS AND STANDARDS as the condition of the building will permit. Any cost resulting from defective or ill-timed work performed under this Section shall be PART 3- EXECUTION LJ borne by this Contractor. 2.05 DCVICCS A. The latest editions of the following standards(including supplements and official interpretations)are minimum requirements: 3.01 INSTALLATION ����� � 3.03 CUTTING AND PATCHING A. Wiring devices shall be hospital grade and rated at 20 amperes for light switches and 20 amperes for duplex receptacles. Switches, � 1. NFPA 70-National�lectrica]Code(NEC). A. Install lighting fixtures straight and true with reference to adjacent walls,and securely fasten to and support by structural members of the receptacles,and other devices shall be Leviton Decora style,or Pass Seymour,Cooper,or Hubbell equivalent. Color shall be as directed 2. NFPA 72-National Fire Alarm Code. A. Provide all cutYing,trenching,backfilling,patching and refinishing or resurfacing required for electrical work in a manner meeting the by the Architect. building. Refer Yo archiYectural or interior reflected ceiling plans and elevations for exact location offixtures. C011SU�tlllg Eilglfl2el'S, �11C. approval of the Engineer and at no additional cost to the Owner. B. Provide photocontrols,time clocks,contactors,relays,etc.to control interior and exterior fixtures. All items for lighting controls that are Vail: (970) 949-6108 COPYRIGHT 2014 3. NFPA 101 -Life Safety Code. B. GFCI receptacles shall be straight blade feed through type with indicator light that is lighted when device is tripped. B. All openings made in fire-rated walls,floors,or ceilings shall be patched and made tight in a manner to conform to the fire rating for the to be mounted outdoors or in wet locations shall be installed in weatherproof housings. Denver. (303) 278-3820 project No:8739.41 4. NFPA l 10-Emergency Power Systems surface penetrated. C. Switches shall be 120/277V,20A,rocker type. Fort Collins: (970) 221-5691 C. Recessed light fixtures installed in gyp.board or plaster ceilings shall have plaster frames installed prior to ceiling material. Albuquerque: (505)323-9070 5. Conform to all applicable State and Local Codes. 3.04 DGLIVGRY AND STORAGE OF MATERIALS D. Wall Switch Occupancy Sensors: 120/277V,adjustable time delay up to 20 minutes,180 degree field of view switch a minimum covera e area of 300 s uare feet. Passive infrared t e shall be Watt Sto er WS-200. Ada tive technolo e shall be Watt Sto er D. Multi-ballasted fluorescent fixriires shall be dual switched unless noted otherwise. Jackson: (307)739-3944 6. American National Standards Institute(ANSI). A. Arrange and be held responsible for delivery and safe storage of materials and equipment for electrical installation. g q Yp pp p gy�p pp www.bece.com WA-200. E. Fixtures recessed in"t-bar"ceiling shall be supported independently of ceiling system,with four#12 hanger wires up to structure. 7. National Electrical Safety Code(NESC). B. Carefully check materials furnished to this Contractor for installation,and provide receipt acknowledging acceptance of delivery and Secure hanger wires to corners of fixture. Clip fixture to grid on two sides with factory-furnished dips. Final connection to fixture shall C. Area Occupancy Sensors: 120/277V,adjustable time delay up to 30 minutes 260 degree field of view. Manufacture shall be Watt 8. Americans with Disabilities Acts(ADA)and American National Standards Institute(ANSI)117. condition of the materials received. Thereafter,assume full responsibility for its safekeeping until the final installation has been Stopper or approved equaL Model number as shown in the following applications: be made with a flexible U.L.approved assembly. 9. National Electrical Manufacturer's Associarion(NEMA). reviewed and accepted. 1. Small room sensor-Passive infrared type,minimum coverage of 500 square feet. WS CI-300-1. 3.05 PROTECTION OF WORK AND PROPERTY 10. A.I.A."Guidelines for Design and Construcrion of Hospita]and Healthcare Facilities." 2. Large room sensor-Dual technology with both infrared and ultrasonic type sensing,minimum coverage of 1,000 square feet. WS SECTION 16700--COMMUNICATION SYSTF.MS A. Where there are existing facilities,be responsible for the protection thereof,whether or not such facility is to be removed or relocated. 11. Underwriter's Laboratories(UL). DT-300. PART 1- GENERAL Moving or removing any facility must be done so as not to cause interruption of the work of Owner's operation. 12. lnsulated Cable Engineers Association(10EA). 3. Corridor Sensor: Ultrasonic type. Minimum coverage of 90 linear feet. WS WT-2250. 1.01 FIRE ALARM SYSTEM(DESIGN/BUILD) B. Close all conduit openings with caps or plugs during installation. Cover all fixtures and equipment and protect against injury. At the 13. International Buildiug Code. final completion,clean all work and deliver in an unblemished condition,or refinish and repaint at the discretion of the Architect. F. Wall plates shall be 0.035-inch thick,satin finished stainless steel material for finished spaces. A. GENfiRAL 14. International Mechanical Code. C. Any equipment or conduit syste�lis found to have been damaged or contaminated above"MILL"ar"SHOP"conditions shall be replaced 2.06 DISCONNLCTS 1. Modify existing Notifier panel(located in main electrical room)and annunciator panel to accommodate new notification appliances. 15. International Fire Code. or deaned to the Engineer's satisfaction. A. Safety switches shall be heavy-duty,quick-make,quick-break with cover interlock,fusible or non-fusible,and grounding lugs in 2. The system shall comply with the applicable provisions of the Nationa]Fire Protection Association,(NFPA),Standard 72,Uniform � ���+� enclosure to suit locations and requirements. G.E.,Siemens,Square D,Cutler-Hammer. Building Code,Uniform Fire Code,National Electrical Code,Americans with Disabilities Act(ADA),NFPA 70 and 90A. The ��, ,��/ 16. Sheet Metal and Air Conditioning Contractors National Association(SMACNA). 3.06 FINAL ACCCPTANCG � F,] �. � 2.07 FUSES system shall also meet all requirements of the Fire Marshall or Building Authority Having Jurisdiction. All equipment and devices ����;• •����� �� •, � B. Comply with requirements of Underwriters Laboratories for all items installed for which U.L.standards have been established. A. Final acceptance by the Owner will not occur until all operating instructions are received and Owner's personnel have been thoroughly shall be listed by the Underwriters Laboratories,Ina Fire alarm pauel shall be UL Listed as an assembled unit. �C,1 ;' C. The drawings and specifications take precedence when they are more stringent than codes,statutes,or ordinances in effect. Applicable indoctrinated in the maintenance and operation of all equipment. A. Time delay,rejection type,high capacity or current limiting as shown on the drawings. Manufacturers shall be Bussmann,Littelfuse or �: Gould Shawmut. 3. Provide shop drawings showing equipment and device locations and connecting wiring of entire fire alarm system. Include wiring wdes,ordinances,standards and statutes take precedence when they are more stringent or conflict with the drawings and specifications. B. Operating manual,parts lists,and indoctrination of operating and maintenance personnel:Furnish the services of a qualified dia rams, anel la out drawin s,and descri tive literature oF all com onents. U on com letion of ro'ect, rovide to the Owner as � ��`� re resentative of the su lier for each item or s stem itemized below who shall instruct s ecific ersonnel,as desi nated b the Owner, 2.08 STARTERS � p Y g p p p p p � p 1.05 GXAMINATION OF BIDDING DOCUML'NTS p pp Y p p � Y built system plans and 3 sets of system operation and maintenance manuals. �,� E �� � in the operation and maintenance of that item or system. ���i3 ��, '�'^�1- � ��� A. Gach bidder shall examine the biddin documents carefull and not later than seven da s rior to the date of recei t of bids,shall make A. Single phase manual starters sliall be"quick make-quick break"toggle switch. Single or double pole with a thermal overload heater yp q y y � q p q y p g �y, y p p 4. To establish the t e and ualit of s stem desired,the followin e ui ment is considered e uivalent:P rotronics,Sim lex and 'Q ' .� ��' written re uest to the Architect for inter retation or correction of an discre ancies,ambi ities,inconsistencies,or errors therein which C. Deliver three(3)complete operating manuals and parts lists to the Owner(or his designated representative)at the time of the above element capable of interrupting the circuit in case of overload. �.���`'.t,.,�.�s••'� ti q p y p � Notifier. Other manufacturer's equipment may be considered upon proper submittal per Section 16010. �� � he ma discover. The Architect will issue an inte retation or correction as an Addenduin. Onl a written inte retation or correction required indoctrination. Fully explain the contents of the manuals as part of required indoctrination and instruct the Owner's personnel in B. Ma netic controllers shall be full volta e non-reversin across the line starters with ambient com ensated inverse time-current �� �� Y Y � Y � g g ' �' ' p B. Qualifications of Installers:Tl�e entire fire alarm system shall be fabricated,installed,and tested by a contractor with five years ������ b addendum shall be bindin No bidder shall rel u on inter retations or corrections iven b an other method. If discre ancies, the correct procedure in obtaining service,both during and after the guarantee period. The operating manual and parts lists shall give y g. y p p g y y p characteristic and NEMA ICS2,Class 2 tripping characteristic. minimum experience specializing in such systems. If required within jurisdiction oFproject,contractor shall be a licensed specialist. ambiguities,inconsistencies,or errors are not covered by addendum or written directive,Contractor shall include in his bid,labor, complete information as to whom the Owner shall contact For service and parts,induding the address and phone number. Furnish � evidence that an authorized service or anization re ularl carries a com lete stock of re air arts for these ite�ns or s stems C. Combination Magnetic Controller: Factory-assembled combination controller and heavy duty disconnect switch. materials and methods of construction resulting in higher cost. After award of contract,no allowance or extra compensation will be g g Y P p p ( y ),and that C. Submittals: made on behalf of the Contractor due to his failure to make the written re uests as described above. the organization is available for service. Service shall be furnished within twenty four(24)hours after requested. D. Provide two normally open and two normally closed auxiliary contacts for each single speed motor and for each speed of multi-speed q 1. Shop drawings:Before any fire alarm system materials are delivered to thejob site,submit complete shop drawings to the architect D. Clean tt Reinove all materials,scra motors. B. Failure to request clarification during the bid phase of any inadequacy,omission,or conflict will not relieve the Contractor of their p� p,etc.,relative to the electrical installation and leave the premises and all equipment,lamps, in accordance with the provisions of these specifications. �, � E. Enclosure shall be NI,MA 250 T e 1 for dr indoor locations NCMA 250 T e 3R for outdoor NEMA 250 T e 4 for dam /wet Issue/Revisions Date IVO. I responsibilities. The signing of the contract will be considered as implicitly denoting that the Contractor Ilas a thorough comprehension fixtures,etc.in a clean,orderly condition. Any costs to the Owner for clean up of the site will be charged against the Contractor. , YP Y = � YP > > YP P a. Prior to submittal for architect's review,secure approval and stamp of acceptance of the Fire Marshall/District Having of the full intent and scope of the working drawings and specifications. E. Acceptance Demonstration: Upon completion of the work,at a time to be designated by the Architect,the Contractor shall demonstrate locarions,and NEMA 250,Type4x for kitchens. Jurisdiction. 1.06 EXAMINATION OF PREMISES for the Owner the operation of the entire installation,including all systems provided under this contract. F. Starters which are furnished with control circuits shall have integral transformer(with sufficient capacity to operate connected devices b. Upon request,the Architect with furnish without charge to the contractor one set of reproducible transparencies of those plus 100%spare capacity)and 120 volt control circuit. All starters to have thermal overload relays sized for approximately l 15%of full A. Visit site prior to bid and verify that conditions are as indicated. Contractor shall include in his bid costs required Yo make his work meet F. Operating and Acceptance Tests: Provide all labor,instruments,and equipment for the performance of tests as specified. Submit three drawings included in the contractor documents which may be suitable for use in preparation of shop drawings. 3 co ies of a t ewritten test re ort for the Architect for his a roval. load motor current. existing conditions. � ) P YP P PP a Shop drawings shall include: 1.07 EXISTING CONDITIONS 1. Record d�e full load ctiu-rent in each phase or line at the main service entrance and for each feeder leaving the main distribution PART 3- �XECUTION 1) Layout drawing of the complete fire alarm system indicating relationship of all other overhead items including ceiling air panelboard. Readings shall be taken with the maximum installed load connected and in operation. 3.01 CONDUIT INSTALLATION diffusers,li htin fixtures,and all other items. A. Existing systems and conditions shown on drawings for existing buildings are to be noted"for guidance only". The Electrical Contractor g g shall field check all existing conditions prior to bidding and is to include in his bid an allowance for extension,removal and/or relocaCion 2. Perform a careful inspection of the main switchboard bus structure and cable connections to verify that all connecrions are A. AIl wiring shall be installed in listed EMT raceways. 2) Complete details and secYions as required to clearly define and clarify the design, including a materials list describing all of existing conduits,wires,devices,fixtures,or other equipment as indicated on the plans or as required to coordinate and adapt new and mechanically and electrically kight. B. Make conduit bends with standard conduit elbows or conduit bent to not less than the same radius. All bends s11a11 be free from dents or proposed materials by manufacturer's name and eatalog number. existing electrical system to all other work. 3. Measure the resistance to ground for the service ground,which sl�all not exceed Yen(10)ohins under normal soil inoisYure flattening. 3) As-Built Drawings: During progress of the work, maintain an accurate record of all cllanges made in the 6re sprinkler B. System outages shall be permitted only at times approved by Owner in writing. Wark which could result in an accidental outage eonditions If required,install additional ground provisions in a manner accepted by the Engineer at no additional cost to the Owner. C. Run concealed conduits in a direct line. Run exposed conduits}�arallel to,or at right angles with,lines of the building. Install all system installation from the layout and materials shown on the reviewed shop drawings. (beyond branch circuits)shall be performed with the Owner's maintenance personnel advised of such work. 3.07 IDENTIFICATION conduits at least 6"away From flues,steam and hot water pipes. [nstall horizontal raceway runs above water and steam piping. 4) Manual: Upon completion of this portion of the work,and as a condition of its acceptance, deliver to the architect a copy C. Service shall be maintained to existing areas during construction. Contractor shall provide portable generators,cables,outlets,etc.as A. General: Provide the following services and materials to assist the Owner in operation and maintenance. D. Seal all conduit penetrations oF fire rated walls,floor,or ceilings with U.L.listed"Dow Corning"#2000 or#2001 fire stop sealant or of a manual complied in accordance with the provisions of Sections 16010 and 16100 of these specifications; include a required to maintain continuity of service. Placement of such partable equipment shall be subject to Owner approval.Generator system equivalent. copy of the as-built drawings. B. Directory Cards,Nameplates and Labels:No temporary markings,which are visible on equipment,shall remain after the project is shall be complete and operable and shall include required accessories,fuel tanks,piping,muffler,block heater,battery charger,ete. com lete. Re aint trims,housin etc.,where such markin s cannot be readil removed. Defaced finishes must be refinished. AII E. All em t racewa s stems shall have a ol ro lene ullwire or e ual,and shall be identified at all'unetion, ull and termination p p g, g Y P Y Y Y P YP PY P 9 J P D. Provide new updated panelboard directories for existing and new circuits being utilized for completion of project. engraved metal or plastic nameplates shall be white letters on a black or gray background. Raised letter type tape shall not be used. No points using permanent metallic tags.Tag shall indicate intended use of conduit,origination,and termination points of each individual 1.08 PERMITS,FCES&NOTICI;S abbreviations in labeling will be permitted without special approval. All panelboards shall be labeled as designated on the electrical conduit. drawings. Thoroughly dean surface to which pressure sensitive type labels are applied to assure adherence of labeL Directory cards, F. Conduits penetrating through roof shall have roof flashing with caulk type counter flashing sleeve. Installation shall be watertight. A. Obtain and pay for all necessary permits,inspections and certificates that may be necessary far the full completion of the work. Furnish nameplates,and labels shall indicate Che general area and type of electrical load served by each circuit. Provide the following types of the Owner with a certificate of final inspection and approval from the AHJ over the electrical installation. labels at these locations. 3.02 WIRE INSTALLATION Projeet I nformation B. Notify proper authorities when wark is ready for inspections required by applicable codes,rules and regulations,allowing sufficient time 1. On each feeder switch,combination starter,or circuit breaker located in motor control centers,main service equipment,the main A. Branch circuit conductors shall be as follows: for inspections to be made without hindering progress of the work. Furnish to the Owner copies of inspection certificates of acceptance. switchboard or panelboard,subdistribution panelboards,and all special equipment housed in cabinets,the labeling shall be one 1. For general applications through size#8: THHN/THWN 75oC wire and full size ground,or type THHN 90oC. 1.09 TGSTS fourth inch(1/4")minimum height letters. 2. Branch circuit conductors through size#10 to be solid,#8 and larger stranded. A. Upon completion oF all work and adjustment of all equipment,provide complete operational tests of all electrical equipment provided 2. On each separate mounted disconnect and starter for a motor or fixed appliance,indicate motor or appliance designation,voltage, 3. Unless indicated on the drawings,(the minimum)wire used for branch circuits shall be#12 THWN protected by 20 ampere circuit � under this division. and phase. (Motor or appliance designations shall be as given on the Mechanical or Architectural plans.) Use three-sixteenth inch breakers. ��]�� Q1.10 WARRANTY (3/16")minimum height letters. B. The drawings indicate the general direction of routes of branch circuit home runs. Continue all such home runs to panels as though the �'t' � A. Guarantee that all work overned b this division shall be free of deFects in workmanshi materials and arts for a eriod of one 1 ear 3. On all branch circuit panelboards indicate panel designation,voltage and phase. Use three-fourths inch(3/4")minimum height routes were com letel mdicated. J' g Y P P P � )Y P Y ♦ ����� after written acceptance.Promptly repair,revise,and replace defects as directed with no additional cost to the Owner(latnps and fuses stenciled letters in metal tape or one-half inch(l/2")engraved letters on laminated nameplate. Apply to the inside of each door. AIl 1. Conductors shall be continuous from outlet box to outlet box,or junetion box,with no splices except in such boxes. � are exempt). emergency panels and disconnects shall be painted with red enamel. 3.03 WIRING DEVICC 1NSTALLATION rn 1.1 1 RCCORD DRAWINGS 4. For all branch circuit panelboard directories,provide neatly typed,removable cards and protective plastic faces. Spare circuit � � breakers shall be identified as such. A. Review architectura]and mechanical drawings before installing outlets. Cllanging of outlets to conform to these drawings and any other cy A. During the progress of the work,maintain an accurate record of the installation of the electrical system.Upon completion of the electrical slight change in mounting height or location of outlets required shall be considered as a part of this conh�act. Use outlet boxes of M�d��a� � installation,transfer all record data to prints of the original drawings.Drawings shall indude all addendum items,change orders, 5. For all device plates for switches used to control exhaust fans or other equipment,provide one-eighth inch(1/8")minimum height sufficiene size and shape to best suit the particular location and to contain the enclosed wire and connections without crowding. Size all � alternates,reroutings,etc.As a condition of acceptance of the project,deliver to the Architect one copy of the record drawings. black filled,engraved letters on stainless steel device plates. boxes per N.E.C.Article 370. ������ � 1.12 PROTECTION 3.08 CONSTRUCTION LIGHTING AND POWER B. Switch and receptacle outlet boxes shall be standard boxes with cover plates. Where more than one switch or device is located at one �,j A. Of People:Arrange barriers,signs,etc.as required to minimize the hazard of people. Comply with applicable safety and health A. Provide all temporary facilities required to supply construction power and light Install and maintain facilities in a manner that will point,use gang boxes and gang cover plates. � regulations. Coordinate as necessary with the Owner and the General Contractor. protect the public and workmen. Comply with all applicable laws aud regulations. � C. Receptacles in wet locations shall be installed with a hinged outlet cover/enclosure marked"suitable for wet locations while in use"and i B. Of Work:Take all measures necessary to protect the work both before and after installation,to assure that it will be in clean,undamaged, 3.09 REMODELING PROVISIONS "UL listed".There must be a gasket between the enclosure and the mounting surface,and between and hinged cover and mounting � unbleinished condition when turned over to the Owner. Re air/re lace work dama ed durin construction. late/base to assure ro er seal. Ta mac;s ecification ade or e uivalent. � P P g g A. Existing systems and conditions shown on the drawings are provided for guidance only. The Electrical Contractor shall field check all P P P Y P � 9 PART 2- PRODUCTS existing conditions prior to bidding and shall include in his bid an allowance for the removal and relocation of existing conduits,wires, D. Flush mount lighting switches 4'0"centerline above finished floor unless otherwise indicated. Flush mount wall type receptacles and -�v devices,fixtures,or other e ui ment as indicated on the lans or as re uired to coordinate and ada t new and existin electrical s stems `, . . 2.01 STANDARD FOR MATERIALS 9 P P 9 P g Y other wall mounted wiring devices and outlets ]8 inches centerline above finished floor unless otherwise indicated. Y a i I S u m m i t � to all other work required far this project C. Route dedicated neutral conductors on line and load side of dimmers er manufacturer's instructions. � A. All electrical material shall be new and of the quality and type specified. p N B. Connect new work to existing in a manner that will assure proper raceway grounding throughout in conformance with the National O 1 1,�O a e d i cs � B. Manufacturer and catalo number shown in these s ecifications or on drawin s are intended as a uide to ualit F, uivalent materials F. Identify panelboard and circuit number on receptacles with hot stamped or engraved machine printed label on face of plate. „ � P g g 4 Y� 4 Electrical Code. � T and equipment of other manufacturers will be considered provided such substitutions are requested in accordance with the provisions of 3.04 ELECTRICAL SUPPORTING DEVICES m C. Remodel Work Cutting and Patching: The Contractor shall perform cutting,channeling chasing drilling etc.,as required to install or -6 paragraph 2.03 and shall include all infarmation necessary to support the claim of equivalency. remove electrical e ui ment in areas of remodelin This work shall be erformed so as to ininimize dama e to ortions of wall finishes, A. Support all panels,junction boxes and other electrical devices in a manner as required by the N.E.C. Use extra bracing,supports,etc.as � C. No extension of completion date shall be allowed for time losY in consideration,shipping,or installation of approved substituYions. surfaces,plastering,o rthe structure which are to be reused,resurfaced,p astered or painted under another digvisi n of these necessary to provide a proper and substantial base to which all electrical equipment is attached. '�- Review of substitutions signifies general equality of materials and equipment only. This review does not relieve tl�e Contractor of s ecifications. U S' B a n k B U��d�n g � P 3.05 EQUIPMCNT FURNISHED BY OTHGRS and/or owner responsibility for proper operation of the system,compliance with specifications and necessary changes due to dimensional differences � or space requirements. D. Carefully coordinate with the required remodeling work,cutting and patching ete.,performed by the other trades. Remove or relocate A. Verify exact location and requirements of equipment to be Fiirnished by oYhers prior to rough-in. 3 existing electrical conduits,wires,devices,fixtures and other equipment as necessary. B. See Division 15 drawin s for locatiou of inechanical e ui ment. Provide service to,and connect e ui ment as re uired. ����� ��� � 2.02 SHOP DRAWINGS g q p a p q o' E. All outages on portions of existing electrical systems shall be minimized and shall be at a time and of duration as accepted by the Owner. C. Inspect owner furnished equipment for damage,defects,missing components,ete. Report deficiencies to the Owner immediately. Do A. Shop drawings/project data sheets required for this project are as follows: not install or connect deficient equipment. ��$ �'DUth Fr�ntage R�ad W 3.10 ELECTRICAL DEMOLITION d, 1. Lighting fixtures � A. Examination 3A6 EQUIPMENTCONNECTIONS Vail Colorado 81657 � 2. Panelboards 1. Verity field measurements and circuiting arrangements are as shown on drawings. A. Final connections to motors,transformers and other vibrating equipment shall be with seal tite flex and approved fittings. Do not secure ' � 3. Wiring devices conduits,disconnects,or devices to ductwork or mechanical e ui ment. � 2. Verify that abandoned wiring and equipment serve only abandoned facilities. 9 P 4. Fire alarm and detection system U 3. DemoliCion drawings are based on casual field observation and existing record documenYs. Report discrepancies to ArchiYecY before B. Final connections to equipment shall be in accordance with manufacturer's approved wiring diagrams,details,and insYructions. It shall _� w 5. Disconnects disturbing existing installation. be the Contractor's responsibility to provide materials and equipment compatible with equipment actually supplied. Sheet �nf�rmatl0n U 6. Fuses 4. Beginning of demolition means installer accepts existing conditions. C. Electrical Contractor shall provide controls,interlocics,accessories,etc.in motor control starters as required by the temperature control � B. Provide roduct data sheets/sho drawin s er Division l. Contractor. Starters shall contain 120V control transformer,pilot lighY,and pushbuttons or selector switch as required,in addition to 00 P P B P B. Preparation Sheet Title: � other items(auxiliary contacts,door switches,relays,etc.)required. Submit elementary control diagrams. � C. Place orders for all equipment in time to prevent any delay in construction schedule or completion ofproject. If any materials or I. Disconnect electrical systems in walls,floors,and ceilings scheduled for removal. U equipment are not ordered in time,additional charges made by equipment manufacturers to complete their equipment in time to meet E L E C T R I CA L t 2. Coordination outages with ArchitecUOwner. � construction schedule,together with any special handling charges,shall be borne by the Contractor. SECTION 16400--SERVICE AND DISTRIBOT[ON '� 3. Provide temporary wiring and connections to maintain existing systems in service during construction. When work must be D. Shop drawings: Contractor agrees that shop drawing submittals processed by the engineer are not change orders;that the purpose of PART 1- GENERAL �- performed on energized equipment or circuits,use personnel experienced in such operations. shop drawing submittals by the Contractor is to demonstrate to the engineer that the Contractor understands the design concept,that he PART 2- PRODUCTS ����� ��������� � demonstrates his understanding by indicating which equipment and material he intends to provide and by detailing the fabrication and 4. Fire protection,fire alarm,and detection systems shall be maintained and capable of proper operation during construction. The local � installation methods he intends to use. Contractor further agrees that if deviations,discrepa�icies,or conflicts beYween shop drawing Rire Marshall shall be notified before construction starts,when scheduled interrupeions are expected and after construction is 2.01 Panelboards � submittals and contract documents in the form of design drawings and specifications are discovered either prior to or after shop drawing complete. Protect and support life safery systems routed through areas of demolition. A. Bolt on circuit breaker type with hinged door,indoor circuit directory. Circuit breakers to meet the non-interchangeability requirements � submittals are processed by the engineer,the desig��drawings and specifications sl�all control and shall be followed. 5. Existing telephone system:Maintain existing system in service. Disable system only to make switchovers and connections. Notify of the N.G.C.wliere applicable;all breakers 20 ampere single pole unless otherwise noted;all multiple units common trip. Mains with � 2.03 BID ALTERNAT�(S) Owner/Architect in writing at least 24 hours before partially or co�npletely disabling sysYem. Minimize outage duration. lugs or main circuit breakers as shown on the panelboard schedules. All panels to have neutral and ground bus. General Electric,ITE, Q Square D,Cutler-Hammer equivalent. o A. Refer to Division 1 for additional information. C. Demolition and Extension of Existing Clectrical Work -� B. Molded case circuit breakers with series-connected rating to meet available fault currents. GFCI circuitbreakers shall be single or two � B. Alternate(s)for Material and Equipment ]. Remove,relocate,and extend existing installations to accommodate new construction. pole configurations with Sor 30 mA trip sensitivity. 1. fiquipment and material bid alternate(s)shall be proposed as additive or deductive alternate(s)to specified items by submitting it as 2. Remove abandoned wiring to source of supply. PART 3- �XECUTION �',��PE RM�T Q3�Q3�2��L�. � a separate line item from the base bid on the Bidder's letterhead. 3. DisconnecY abandoned outlets and remove devices. Remove abandoned outlets if conduit servicing tl�em is abandoned and removed. E 3.01 MOUNTING � 2. Such bid alternate proposals shall not be substituted or induded in the base bid. Bid alternate proposal(s)must be accompanied by Provide blank cover for abandoned outlets,which are not removed. S I�eet N U CT�ber. � A. Install distribution equipment in accordance with manufacturer's recommendation,and as shown on the drawings. full descriptive data on the proposed equipment,together with a statement of the cost to be added or deducted for each item. The bid 4. Disconnect and remove electrical devices and equipment serving utilization equipment that has been removed. �ea alternate shall include all materials,equipment,labor,connections,coordination with all other trades,etc.for a complete and B. [nstall wall-mounted equipment 5'0"centerline above finished floor unless otherwise indicated. � o erational s stem. 5. Disconnect and remove abandoned luminaires. Remove brackets,stems,hangers,and other accessories. P Y C. Install top of panelboards 6'6"above finished floor unless otherwise noted on the drawings. Mount plumb and rigid without distortion � 3. The Contractor shall submit the bid alternates at the time the base bids are due. 6. Repair adjacent construcYion and finishes damaged during demolition and extension work. of box. Mount recessed panelboards with fronts uniformly flush with wall finish. M 2.04 SUBSTTTUTiONS 7. MainYain access Yo existing electrical installations,which remain acYive. Modify installation or provide access panel as appropriate. 3.02 identification � 8. Cxtend exisYing installations using maYerials and methods compatible with existing electrical installaTion,or as specified in � A. Bidder's Choice:Material or equipment listed by several manufacturers'names are intended to be bidder's choice,and any of the listed A. Identify panelboard name,voltage and ampacity with engraved machine printed nameplate on panelboard n2ounted with corrosion ■ v manufacturers may be used in the base bid. individual section. resistant screws. � D. Cleaning and Repair 'p B. Performance Specifications:When any item is specified by requirements to meet a performance,industry or regulating body standard,or B. Create a typewritten directory schedule indicating installed circuit loads mounted to inside door cover in removable transparent pocket. � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ _ ■■ ■ ■ � NOTES: � � � � � 1. PROVIDE DEVICE BOX WITH CONDUIT UP TO ■ . ■ . - �� f / CABLING TE MIINA ONOSRAND DEV CESTPROVIDED ■ ■ ■ ■■ 2F-11 2F-11 2F-11 i I � BY OTHERS. REFER TO DIAGRAMS A AND B, SHEET � E3.1 FOR DETAILS. � � 2F-1 alJ��ii� �/V�n✓ 2, REFER TO X-RAY PLANS(SUBMITTALS)FOR FURTHER 203 � �� ���� i DETAILS ON IMAGING EQUIPMENT.COORDINATE ALL _ CONNECTIONS TO EQUIPMENT WITH X-RAY SHOP DAV I S DRAWINGS/SUBMITTALS PRIOR TO ROUGH-IN. 2F-3 i 2 � '� PARTN E RSH I P � 3. REFER TO DIAGRAM C, SHEET E3.1 FOR X-RAY � W�, .N� i EQUIPMENT RACEWAY DIAGRAM. ��» � � ARCH ITECTS � 4. FIRE ALARM DEVICES ARE SHOWN TO INDICATED � -11 � DESIGN INTENT. CONTRACTOR SHALL BE OR OBTAIN � J i ENGINEER OF RECORD. Denver I Denver, CO 80205 303.861.8555 � 2301 Blake Street Suite 100 2F-1 0 �J 2F_3 � � \ J _� 5 EXISTINGR UIDL NG FIRE ALARM SOYSTEMTED TO - i +40�� +40„ � � _ � CONTRACTOR SHALL BE RESPONSIBLE FOR Vai1I0225 Main Street, Unit C101 �� �� 2F-11 P VERIFYING THAT INSTALLED DEVICES ARE Edwards, CO 81632 970.926.8960 � _: � J ; 1 COMPATIBLE TO EXISTING FIRE ALARM SYSTEM. g 2F 2F-46 13 2F-42 �2F-42 � � � i . -, F N1H Consultant _ _ ,, ' 2F-4 ,� ,� � 2F-42 � = � � � FLAG NOTES: ,' i - � r- --2F- 2�-�- �F=�--� ,� i i � � ������ i i C H C CORRIDOQ 1� PROVIDE COMBINATION (2)PORT USB CHARGING �/ � � �� � 2F 9 �9 � 200 OUTLET WITH A SIMPLEX RECEPTACLE,LEVITON# 2F-16 - ---- ---------- �� O � �2 � i � T5830 OR EQUAL. MOUNTED ABOVE COUNTER. , s � � � c �� `� 2F-�s � 2F s B EAUDIN � i 2F 9 O2 DATA AND POWER FOR WALL MOUNTED DISPLAY ���� 2F-4 �---i-- -----i ----------- � 2F-46 � � � ; , i i i � VERIFY MOUNTING HEIGHT OF DEVICE WITH TENANT 10 i i i � i � i PRIOR TO ROUGH-IN. ANZE �,'� / ' 2F-9 F-�� � Consulting Engineers, Inc. � --I--------I------- � � � ) COPYRIGHT2014 � ' � I I � CAST � �� �� _ 3 PROVIDE DEVICE BOX IN CABINET CONDUIT UP TO Vail: 9�0 94s-61o8 2F-4 cXAM �� �� 706 � � ,� ACCESSIBLE CEILING FOR FUTURE AV/SPEAKER Denver. (303) 278-3820 Project No:8739.41 � 2F-44 X-RAY � � � I I WIRING. INSTALL PER DIAGRAMS AAND B, SHEET FortCollins: (970) 221-5691 204 I I � �05 � � � FB � � E3.1. Albuquerque: (505)323-9070 � � � Jackson: (307)739-3944 �' � O �L � � i 2F-11 2F-33 � � ' " O4 PROVIDE WALL HUNG PHONE COVER PLATE. W`N`N.bece.com � � � � RECE�T.O'�I � � J i Z�i PIER i O5 PROVIDE TWIST LOCK RECEPTACLE L5-30R FOR � Z J C 2F-44 O� � � i 3 1 3 � � � � UPS.CIRCUIT TO DEDICATED 120V 30A CIRCUIT. r - ---- I` 2; -4 2F-4 11 r----�F-44 2F-16 i � � _ � � � -!�Q _ u d o ----- -��- 6 8"x8"x4"ELECTRICAL BOX FLUSH IN FINISHED - O CEILING BOX TO BE ATTACHED TO WALL. C 2F-16 F-6f - C 2F-5 2F_5 2F� C �� � O7 3-1/2"x 10"ELECTRICAL WALL DUCT FLUSH r � � FB 2F-5� � Q � Q� 2F-7 j ,/��, ° � MOUNTED, EXTENDING FROM FLOOR TO 12"ABOVE � �q� � FINISHED CEILING. COVER PLATE TO CONTAIN(2) FB " � o ' ,J A I�I I T O R v ��c F-6 �.� 3 e 207 2-1/2"CLOSE NIPPLES 24"ABOVE FINISH FLOOR. ��;�., ��.`�, �� � 2F-15 ��F-15- 2E15 -- � O8 12"x12"x4"ELECTRICAL JUNCTION BOX. BOTTOM OF �� '�•rw ��.`+ ��`� - � � � C H � i � ' BOX AT 18"AFF. LEAVE 6'WIRETAILS IN BOX. EC TO �; - E , 2F 20 � � �� _c o c i , O � CONNECT POWER LINE TO X-RAY POWER CABINET S • F-�0_ . ]� � NURSE � CR i CR tW � �2F-10 �R i EXAM AFTER IT IS SET IN PLACE. , � � � ;� �� �� � I I � 2F-14 i 2F-12 i 217 "�,Ae: �j��-'�� � �,,�[* � �•-.,. , t, 2F�20 �i -�........••• � 2F-10 i �B �� n ^ n\ ,I O9 PROVIDE SWITCHED DUPLEX OUTLET. �� � � 1 _ __ li i � e I � IVI � � V 10 i � i i O PROVIDE 10 FT. LENGTH OF WIREMOLD#2600 CABLE �����'�`� � >XAM �i i EXAM EXAM i �i 2F-15 � � WIREWAY AND 1 EACH#2611 90 DEGREE CORNER. ZF$ 2F-8 �� 2�� i 209 208 i 2F-1 i � � X-RAY INSTALLED WILL CUT AND SCREW TO FLOOR i i i i � � � � � 11 6"x6"x4"ELECTRICAL BOX BOTTOM OF BOX AT —, � � i i i i � / _ � ' � �i / i � � O 42"AFF.COVER PLATE TO CONTAIN 1 EACH 1-1/4" Issue/Revisions Date IVO. I 2 2F 14 i i 2F-12� 2F-10 i i - i i \� i i ,, ' TWO SCREW CABLE CLAMP CENTERED IN COVER. � � I�I� � r� � �� � �� i -i A L L. 12 PROVIDE 150 AMP,2-POLE ENCLOSED CIRCUIT i � 2F�i 10 i 21'� = BREAKER FOR POWER LINE. MOUNT AT 5'AFF TO _ __ � � � i � � � P A 2F-8 � i 2F-17 -��Z- C2�- ;�-� CENTER. �� �i i � � � � 2F-10 i � 21� 2F-14 I � 2�`�2 � �i � i 2F-10 � � 13 6"x6"x4"ELECTRICAL BOX. BOTTOM OF THE BOX AT � +24".COVER PLATE TO CONTAIN 1 EACH 1-1/4"TWO , _ _ ! �I,. _.._._..__. . _ _-.---I_ f l: . r----------- __ _ _ --- EXAM SCREW CABLE CLAMP CENTERED IN COVER. �j � t C 2F-14 ZF-14 2� _. F-1� C 2F-11� � 2F-13 218 � / 2F-13 � 14 EXHAUST FAN TO BE CONTROLLED BY RESTROOM � � � � � 1 �� ' / � OCCUPANCY SENSOR. f� � ��0c �`°��� � ; i '� � i � ------------------- 2F-41 2F-25 2F-2� 2F-25 2F- i i ----- — - -----_�� 2F-18 2F-18�2F-18 � �- � ------- �I - i 2F-17 � � � � � �� � 2F-1 i r I. ,.r \� C �i � i L, i i � � �2 i i �_ i FB � 2F-41 �_, F-�41 i � i � �C� 9_ - � - 'L- � � ���� � - - ----- - - ---- --= � Project Information �i�_, � � ���� , �--- — — � � . � �� � � � F-�3 d � 2�-2 ; � �? � c c \ C ' �� F-�1 � � EXAM �� �i � v �'�� �� 2F�23 i 2�5 F-13� �i LF_21_2F-�-21--F�19- 2F-1�2F 19 �� � ��� ������ C � ° PA � � i C � � � U �_ � � , i � �t4 2F-23 � i 2F-13 �� �0�,]� � Q � ��R_____ ____________ Q � Vall JG/i' � _ F � � � FB N��SE � Valley a � 219 � ADMIN � � • M H A ,. � ,3 � ��, �������R Medlcal � PANEL'2F' �30 0 2F-41 � _._, (2-#10,#10 G)3/4"C 2F-19 H _ _ N - G- � - , � -� Center � � � I 01 L 2F_2g 5 (E) � � E 224 \ � +48" 2F-27 � � � jERV� � � 14 HALL 222 � � +60" � 223 � Vail Summit � Fg Fc 2F-31 0���=::N o����!cr T 6 � 2F-35 2?g Orthopaedics � C � � 2 F-35 � -38 H a - US Bank Building Suite 206 � 2F-66 DISP 2F-38 H � 2F-60 C C o MW 1 2F-60 �W 2F-26 �E� � � �� �_; 108 South Frontage Road � � ,�,� `— 1 Vail, Colorado 81657 � �;�,, � REF lf� ���` ��� I �I � Q 2F-34 �� �� � � U i _ / —� w �!o�z,���� � �� Sheet Information t� V ��� %���� BREAK � 2�6 c� m +4g" 225 _ _ � �� ��� �9 0 �-_ �� � . �� ���//i� /j"��� ��;A�. H Or r I�� 0'-'- C,- heet Title: U �;�i �.. � 2E-39 227 2E-39 2E-39 22� 2E-39 — — � � �f \\'� ELECTRICAL � �� ,�, � � � � 2 E-39 � � �F-6o ��� ������ ���� � � P W E R P LAN � — � >� � �� � � � �E� ���� °��� -- �E �E) �E) � a� n 0 � L O �� CD/PERMIT 03/03/2014 � �, Sheet Number: �� ELECTRICAL POWER PLAN > � SCALE: 1/4" = 1'-0" M � W � N U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ LUMINAIRE SCHEDULE ■■ . ■ - RECESS LAMPS SPECIFIC ■ . ■ TYPE DESCRIPTION MOUNTING DEPTH QTY TYPE INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER NOTES ■ . F1 RECESSED MOUNTED 2'X4'LED FIXTURE. RECESSED 3-1/4" - 3500K LED 48 MVOLT COOPER 24AC-LD3-48-UNV-L835-CD1-U ■ . ■ . - F2 RECESSED MOUNTED 2'X4'LED FIXTURE WITH BATTERY RECESSED 3-1/4" - 3500K LED 48 MVOLT COOPER 24AC-LD3-48-UNV-L835-EL-CD1-U ■ ■ ■ ■■ PACK. I I F3 RECESSED MOUNTED 2'X2'LED FIXTURE. RECESSED 3-1/4" - 3500K LED 30 MVOLT COOPER 22AC-LD3-27-UNV-LS35-CD1-U DAVI S AD M I N WO R K F6 WALL MOUNTED ABOVE VANITY WALL SCONCE. SURFACE N/A - 3500K LED 24 120 COOPER 605-25-W-L5/835-120V-NA z1o�� ' ' i R2 � PARTN E RSH I P � � � � � (�J� � � F7 1'X4'FLUORESCENT WRAP AROUND SURFACE N/A (2)32W T8 3500K 62 MVOLT COOPER WE 2 32 UNV EB8 � ARCH ITECTS i � P� DECORATIVE PENDANT WITH DARK BROWN SHADE AND pENDNAT N/A E26 T9 30W 30 120 LBL LIGHTING LF 581 BR SC 2D SATIN NICKEL FINISH ' �- i '� ' I 2301 Blake Street, Suite 100 � ,�� Denver Denver, CO 80205 303.861.8555 � - I �T R1 OPEN LED RECESSED DOWNLIGHT. RECESSED 6-1/2" - 3500K LED 25 MVOLT COOPER LD610D010-ERM6835-6LMOLI-HB26 � � Vail 0225 Main Street, Unit C101 F1 i LD4A 18 DE010 ERM4A 18 9 34 4LM111 Edwards, CO 81632 970.926.8960 � � �� R2 WALL WASH LED RECESSED DOWNLIGHT SURFACE 5-5/8" - 3500K LED 40 120 COOPER WH WF � � � � �� � Consultant = R2 U1 3'LED UNDERCABINET LIGHT SURFACE NA - 3500K LED 28 MVOLT COOPER UCL 3 LD2 35 A12125 ED UNV n n I �-, UNIVERSAL MOUNT LED EXIT SIGN WITH RED LETTERS X1 AND ALUMINUM HOUSING.PROVIDE MOUNTING AS SURFACE N/A - LED W/FIXTURE 5 MVOLT EVENLITE RZR-EM-X-1-AA I I I I I X1 � 1 INDICATED ON DRAWINGS. R1 I I I � R1 R1 __. _._ ___ __._._ � I � I I I I UI �� �� � ��� � �� �� —��- ��� � CORRI DOi� XR1 X RAY IN USE SIGN LIGHT RECESSED LED W/FIXTURE EVENLITE RCG AC B WH 1 WW W (�� B EAU DI N m I � I I I I �� � �� � �� GENERAL NOTES: �ANZE � I I A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE Consulting Engineers, I11C. I I I I I ' � PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. Vail: (970) 949-6108 COPYRIGHT 2014 R1 I I I I R1 R1 � Denver. (303) 278-3820 Project No:8739.41 I I I I I B. ALL FLUORESCENT LAMPS ARE TO BE 3500°KELVIN COLOR TEMPERATURE Fort Collins: (970) 221-5691 P C. Albuquerque: (505)323-9070 � _ F2 SPECIFIC NOTES: Jackson: (307)739-3944 F1 CAS� www.bece.com y ;� �' I I X PAY I � ?_06 I � (1) PROVIDE CUSTOM GRAFICS TO READ"X RAY IN USE"INTERCONNECT TO X RAY EQUIPMENT. � �-�:' � I � 205 � � ��� I � I � _ F1 � � � �3� � R1 � � � � R1 1 � � / � "F1.. _�.�— � � I�?o��I 0�J � „. ,. --��--- ---- � � 3 2 -�9 � � � � � � �' o o — -- � NOTES: -_ _ _ : F3 b X�1 I I ' � 1. CONTRACTOR TO VERIFY OCCUPANCY/VACANCY �,A� ����� F1 � � F2 � F1 � SENSOR LOCATIONS ARE PER MANUFACTURER'S �� •"'��.�5��`' ,. � C3 ,-'E� �: I � I � RECOMMENDATIONS. INSTALL PER � � i oc i A�. I.. MANUFACTURER'S WIRING DIAGRAMS. SET TIME I j 201 I ° DELAY ON ALL OCCUPANCY SENSORS TO 30 � 22 rJ e , �� ' O ' ; - _ _ : ��{ F� �-- -- - � � :yi �^�_�e,� �:•�� - ___ I� MINUTES. F3 G � I �� 2. CONNECT ALL EXIT SIGNAGE TO NEAREST � � �� ] \ ���"`•.�. .••"��v� "i� ' - - LIGHTING CIRCUIT, UNSWITCHED. ��'e�+ ���i �,� N d_ � � 1�MRL �� o F1 CXAI� � 3. FIELD COORDINATE CEILING LIGHTING WITH F1 L � � HVAC CONTRACTOR. I I_— j ~_ F1 F1 - F1 � `" � � o -� AM E� E- A�I — Issue/Revisions Date No.� - -� 21� 209 � � FLAG NOTES: � F1 � i � � 1� ULTRASONIC 1000 SQ. FT COVERAGE,CEILING F1 F� � � � , _ � j a�I MOUNTED,VACANCY SENSOR. GREENGATE# � VAC-U-1000-R OR EQUAL. PROVIDE SWITCH PACK , �I, ��i -- � �'��. _ � (#SP15). ?�J� F I r � `T F1 _ .. _ � , , � i � O2 INFRARED(IR)500 SQ. FT. COVERAGE,CEILWG � � � � � �� � MOUNTED,VACANCY SENSOR.GREENGATE #VAC-P-0500-R OR EQUAL. PROVIDE SWITCH PACK __ _ __ __(._. _ � i , -XAM (#SP15). � � \ ' � � O3 WALL MOUNTED ULTRASONIC OCCUPANCY SENSOR. --- � F2 GREENGATE#OSW-U OR EQUAL. F1 _ 4O EXISTING LIGHTS AND CIRCUIT TO REMAIN. ------ ----- ---- - � � r--- - ._ ._ __----- -- - I i — i _I F� ��- i �-I� Project Information I � � � � � � � , � � � � , � � � , ; � , � U ' � � EXAM � i �� U1 . � � _ _ Vail Q _�_ � _ 2,5 , ; _ __ . __-__� __ Ui i J , i i � F1 F1 i i ° PA � Va���y i COA S o ! 21a o i 0 2 M • (v) . . .i . . . ... .. .� �:_� N O � L — — Medlcal � o � i FZ F1 FZ NURS � ° AoMN � � �- o� � �� ;, X� Center ��� � � � CORRIDOR �''� 21 230 0 i — ° - I?ANE� — FIEC �--, � � � G 2 F-41 -�--�— v O 3 3 .',5 — i 01I_� ' ' � ��� z�� ° Vail Summit � � � _ F� � � . � I I U .. � . s�R��R rthopaedics m R1 R1 ��-IAL 2F_37 - oc � 22� , - FFICE � � ` a 22 W ' US Bank Building � � F6 r 4 4 4 SUIte ZO6 � � � i i 0 w 108 South Frontage Road � ' Vail, Colorado 81657 � � i � � � Q2F-64 , ; � i I I . U ,-.!.. � ! I. —� w � � �� � Sheet Information � � �� Sheet Title: � � B�E � °c �r 2A � ELECTRICAL c 22 — ji oC Oh=h=ICE OF�ICE = LIGHTING � � � � �J � = PLAN n 4 4 4 4 O 0 � — L O �� � CD/PERMIT 03/03/2014 � �, Sheet Number: .� > � ELECTRICAL LIGHTING PLAN M � 0° SCALE: 1/4" = 1'-0" ■ � U N .O � DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ FLAG NOTES : NOTES : ■■ ■ - 1. ITEMS IN LIGHT LINE WEIGHT ARE EXISTING TO AHU AC • 1O ELECTRICAL CONTRACTOR SHALL CONFIRM THAT � 2 800 AMP FUSES ARE CURRENTLY INSTALLED IN THIS REMAIN. ITEMS IN BOLD LINE WEIGHT ARE NEW. ■ . ■ FUSIBLE SWITCH. NOTIFY ENGINEER IF THIS ■ . SWITCH IS NOT PROVIDED WITH 800 AMP FUSES. 2. EXISTING INFORMATION OBTAINED FROM"RECORD ■ . ■ . - DRAWINGS"AND SURVEY INFORMATION AND IS O2 REMOVE EXISTING WESTINGHOUSE SINGLE FUSIBLE BELIEVED TO BE CORRECT. IF FOUND TO BE ■ SWITCH AND REPLACE WITH TWO CUTLER HAMMER INCORRECT NOTIFY ENGINEER IMMEDIATELY. ■ ■ ■ ■ #HFD3200. TERMINATE EXISTING CONDUCTORS SERVING 2ND FLOOR HOUSE PANEL ONTO NEW CIRCUIT BREAKER. PROVIDE REQUIRED FILLER LOAD SUMMARY SECTION#1 PLATED IN MDP SECTION#3 TO COMPLETELY PEAK DEMAND ON SECTION#1,2000 AMP DAV I S COVER THE BUS OF MDP SECTION#3. RATED 441 KW ROOF LEVEL x 125%PER NEC 551 KW O 30 DAY TEMPORARY METER TO BE PLACED ON CALCULATED LOAD ON PANEL'3D' FEEDER TO"MMC-2"TO VERIFY MAXIMUM DEMAND CONCEIRGE CLINIC 663 KW PA RT N E RS H I P LOAD. DEMAND LOAD SHALL BE SUBMITTED TO TOV BUILDING DEPARTMENT TO VERIFY THE ADDITION CALCULATED LOAD ON PANEL'2F' 63.0 KW OF X-RAY EQUIPMENT TO METER STACK. TOTAL LOAD ON SECTION#1 680.6 KW A R C H I T E C T S EXIST EXIST EXIST EXIST EXIST EXIST TOTAL AMPS ON SECTION#1 1890 AMPS LOAD LOAD LOAD LOAD LOAD LOAD CENTER CENTER CENTER CENTER CENTER CENTER Denver 2301 Blake Street, Suite 100 3A 3C 36 HHPT 3D 3E LOAD SUMMARY SECTION#3 Denver, CO 80205 303.861.8555 PEAK DEMAND ON SECTION#3(METER 0225 Main Street, Unit C101 #95651),800 AMP RATED 126 KW Val�I Edwards, CO 81632 970.926.8960 x 125%PER NEC 158 KW CALCULATED LOAD ON PANEL'3D' CONCEIRGE CLINIC 66.3 KW onsu tant CALCULATED LOAD ON PANEL'2F' 63.0 KW TOTAL LOAD ON SECTION#3 286.9 KW TOTAL AMPS ON SECTION#3 797 AMPS 3RD LEVEL EAUDIN Cj ANZE � Consulting Engineers, Inc. Vail: (970) 949-6108 COPYRIGHT 2014 Denver: (303) 278-3820 project No:8739.41 Fort Collins: (970) 221-5691 Albuquerque: (505)323-9070 4-#2/�,#6 GRD,2-1/2��C Jackson: (307)739-3944 www.bece.com EXIST EXIST EXIST EXIST EXIST NEW EXIST LOAD LOAD LOAD LOAD LOAD PANEL 2ND CENTER CENTER CENTER CENTER CENTER FLOOR 2C 2B 2D 2E 2A 2F HOUSE PANEL ISC= 17,707 A 150 AMP,2-POLE ENCLOSED CIRCUIT BREAKERFOR X-RAY EQUIPMENT. �����D � �f���� � �s � rJ 4-#4/0,#6 GRD,2-1/2"C 4-#3/0,#6 GRD,2-1/2"C ��fr��,, ���_���:�Rtt��� 2ND LEVE� � ``•-t........a•''`��� ��`S�pNRL�t� Issue/Revisions Date No.� EXIST EXIST EXIST LOAD BANK BANK CENTER PANEL PANEL 1B 1ST LEVEL Project Information J EXISTING BANK SERVICE DISCONNECT U SWITCHES IN MAIN Q ELECTRICAL ROOM Vall �j #83891 #76973 #71820 #76770 � o 0 0 o Valley ° n � Medical �'? 150A2P 125A2P 100A2P 125A2P N #83892 SPACE #84017 VSO X-RAY � � � � � � � � n c'i 100A2P 100A2P 150A2P enter ° #83973 #83967 #83890 #83944 EXISTING BANK � OO OO O MO CT CABINET IN MAIN � EXISTING ELECTRICAL ROOM n � METER � 100A2P 150A2P 100A2P 150A2P #95228 #75896 #83834 PANEL Va i I S u m m it m � � O U A� LE Orthopaedics �' 150A2P 150A2P 1 1 m � F2 MODULAR METER CENTER"MMC-3" F3 MODULAR METER CENTER"MMC-2" a 600A,208/120 VOLT, 3 PHASE,4 WIRE, 600A,208/120 VOLT,3 PHASE,4 WIRE, US Bank Buildin 10,000 A.LC. 3 10,000 A.I.C. g � Suite 206 ° M w 2 SETS OF � 108 South Frontage Road � 4#500 KCMIL AL EXISTING Val�, Colorado 81657 � IN WIREWAY � w � #95651 Q -� w Sheet Information EXISTING HOLY CROSS C7 ISC=90,174 A m ENERGY 500 KVA,208/120-VOLT, heet Title: � 3-PHASE,4-WIRE PAD MOUNTED � U TRANSFORMER 4 4 E L E CT R I CAL `!' 600 AS 600 AS 600 AS 400 AS 400 AS 60 AS 200 AF 200 AF 200 AF 200 AF 200 AS �- 600 AF(JJN) 600 AF(JJN) 200 AT � 200 AT 200 AT � 200 AT � � � � ONE—LINE ~ 800AS D IAG RAM � U � N I Q � I 2 p GARAGE LEVEL .� � � Fo I F1 CD/PERMIT 03/03/2014 EXISTING SECTION#1 EXISTING SECTION#2 EXISTING SECTION#3 � � � � 2000 AMPS 800 AMPS 800 AMPS �, i � � Sheet Number: 208/120 VOLT,3-PHASE,4-WIRE 208/120 VOLT 208/120 VOLT j � J L------- I 3-PHASE,4-WIRE 3-PHASE,4-WIRE __—J � MAIN DISTRIBUTION BOARD-"MDP" M 2000A,208/120 VOLT, 3 PHASE,4 WIRE, n EXISTING � 6SETSOF(3#500KCMIL+1#250G)3���. PARTIAL BUILDING ELECTRICAL ONE LINE DIAGRAM � U N .O � SCALE: NONE DPA Project: 14901.00.000 m COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. � ■�■ ■ ■ MECHANICAL EQUIPMENT SCHEDULE ■� . ■ � MARK DESCRIPTION VOLT/ HP WATTS FLA MCA DISCONNECT/ FEEDER CIRCUIT SPECIFIC NOTES ■ . ■ PHASE FUSE SIZE ■ . EF-1 EXHAUST FAN 120/1 45 2-#12,#12 GRD 2F-39 (2) � � I ' ■ . ■ . - I I � �I ■ ■ ■ ■■ EF-2 EXHAUST FAN 120/1 139 2-#12,#12 GRD 2F-30 � � I I� CONDUIT PATHWAY,UP OR DOWN FROM OUTLET BOX. � � I I � FB-1 TERMINAL FAN BOX WITH 208/1 1/6 2000 30A,2P 4-#12,#12 GRD 2F-45,47,49 (1) COMMUNICATIONS CABLING. �� REHEAT COIL DAV I S ,������� —�� TERMINAL FAN BOX WITH FB-2 208/3 1/6 3000 30A,3P 4-#12,#12 GRD 2F-51,53,55 V 1 I I \� (�1 � I V REHEAT COIL I � I --``� I � I SINGLE DEVICE RAISED COVER. THREADED NIPPLE WITH i i � �— r�t�� r��1 � I I � PARTN E RSH I P TERMINAL FAN BOX WITH I FB-3 208/3 1/4 2500 30A,3P 4-#12,#12 GRD 2F-57,59,61 PROTECTIVE BUSHING. REHEAT COIL I I I\ � I � � I � I� I� �ELECTRICAL OUTLET BOX; TERMINAL FAN BOX WITH i i ��i\ �� �---� i � !�►� 4-11/16"x4-11/16"x2-1/2��. A RC H I T E C TS FB-4 208/3 1/6 2500 30A,3P 4-#12,#12 GRD 2F-48,50,52 � � TYPICAL UNO. REHEAT COIL ( I I I � I I � � I I I L_J I TERMINAL FAN BOX WITH FB-5 208/3 1/6 2000 30A,3P 4-#12,#12 GRD 2F-63,65,67 I � � I � � � � I � � I Denver I2301 Blake Street, Suite 100 REHEAT COIL I I I I I I I I I I Denver, CO 80205 303.861.8555 TERMINAL FANBOXWITH I I � I L—J L—J I � I I FB-6 208/3 1/6 1500 30A,3P 4-#12,#12 GRD 2F-66,68,70 I I REHEAT COIL ( I � I �,�� I � I I Vail 0225 Main Street, Unit C101 I I � I � I � I I I Edwards, CO 81632 970.926.8960 FB � TERMINAL FAN BOX WITH 208/3 1/6 1500 30A,3P 4-#12,#12 GRD 2F-69,71,73 ���rt�'--------'�r��� REHEAT COIL Consultant FC-1 FAN COIL 120/1 12.0 20A, 1 P 2-#12,#12 GRD 2F-36 (3) P-1 HOT WATER RE-CIRC PUMP 120/1 85 20A, 1 P 2-#12,#12 GRD 2F-32 COMMUNICATIONS OUTLET BOX DIAGRAM WH-1 WATER HEATER 208/3 6,000 50A,3P 3-#8,#10 GRD 2F-54,56,58 NO SCALE O B EAU DI N GENERAL NOTES: G ANZE / A. SEE SPECIFICATIONS FOR ELECTRICAL DIVISION AND MECHANICAL DIVISION MOTOR STARTER COORDINATION. PROVIDE INSULATED BUSHING B. PROVIDE PHASE PROTECTION FOR ALL THREE PHASE MOTORS ABOVE 7-1/2 HP. ON END OF CONDUIT. C011SUItlllg Eilglfl2el'S, 111C. C. PROVIDE ALL EXTERIOR DISCONNECTS WITH NEMA 3R RATING. D. WHEN EQUIPMENT IS LISTED WITH ONLY A HORSEPOWER RATING THE DISCONNECT AND FEEDER ARE SIZED PER THE N.E.C. Vail: (970) 949-6108 COPYRIGHT 2014 Denver: (303) 278-3820 project No:8739.41 SPECIFIC NOTES: 6"RADIUS MINIMUM FortCollins: (970) 221-5691 (1) TERMINAL FAN BOX HAS BOTH FAN AND ELECTRIC HEATING COIL-LISTED HP IS FOR FAN AND LISTED WATTS IS FOR THE ELEC.HEATING COIL CONDUIT SWEEP. Albuquerque: (505)323-9070 (2) CIRCUIT EXHAUST FAN ON LIGHTING CIRCUIT, EXHAUST FAN TO BE CONNECTED TO RESTROOM OCCUPANCY SENSOR Jackson: (307)739-3944 www.bece.com (3) POWER TO CONDENSING UNIT(ON ROOF)FROM FAN COIL FOR SPLIT COOLING SYSTEM,COORDINATE WITH MECHANICAL CONTRACTOR. 4 ROUTE CONDUIT TO NEAREST CABLETRAY,OR ARLINGTON PANEL: 2F VOLTAGE: 120/208V, 3PH,4W LOOP/J-HOOK, OR DIRECT TO MINIMUM BUS: 225 DISTRIBUTION FRAME ROOM. LOCATION: ADMIN 205 MAIN: MLO MOUNTING: RECESSED MINIMUM AIC: 22,000 1"CONDUIT. �#� LOAD BREAKER BUS BREAKER LOAD � No. TYPE LOAD DESCRIPTION TYPE LOAD DESCRIPTION No. A B C POLE TRIP A B C TRIP POLE A B C �y 1 540 R ADMIN 203 REC. 1 20 + 20 1 R WAITING COFFEE BAR 360 2 Q 3 540 R ADMIN 203 REC. 1 20 + 20 1 R EXAM 204 900 4 � � 5 720 R RECEPTION 201 REC. 1 20 + 20 1 R NURSE 211 720 6 � 7 540 R RECEPTION201 REC. 1 20 + 20 1 R P/PA212 720 8 � ���� 9 1080 R RECEPTION 201 REC. 1 20 + 20 1 R EXAM 212 1080 10 � 11 900 R WAITING 201 1 20 + 20 1 R EXAM 213 900 12 OUTLET ASSEMBLY. 13 900 R EXAM 215 1 20 + 20 1 R EXAM 209 900 14 15 900 R EXAM 217 1 20 + 20 1 R CAST 207 1080 16 WALL SURFACE(GYP BD). 17 900 R EXAM 218 1 20 + 20 1 R P/PA 212 720 18 19 900 R NURSE 220 1 20 + 20 1 R NURSE 216 720 20 21 900 R NURSE 220 1 20 + 20 1 R DISPOSAL 900 22 FINISHED FLOOR. 23 720 R P/PA 214 1 20 + 20 1 R ADMIN 205 540 24 25 900 R P/PA 214 1 20 + 20 1 A DISPOSAL 1200 26 �� � � 27 2880 E SERVERUPS 1 30 + 20 1 A DISHWASHER 1200 28 � . a ° — � � Issue/Revisions Date IVV. I 29 360 R SERVER 222 1 20 + 20 1 M EF-2 139 30 a � d a A ° � a 31 360 R SERVER 222 1 20 + 20 1 M P-1 85 32 33 1000 E COPIER 1 20 + 20 1 A REFRIGERATOR 1200 34 TELECOM OUTLET PATHWAY DIAGRAM 35 360 CONFERENCE RM 1 20 + 20 1 LM FC-1 1440 36 O 37 1440 L LIGHTING 1 20 + 20 1 R TOILET224 360 38 NO SCALE 39 1061 L LIGHTING 1 20 + 20 1 R X-RAY SWITCHED REC. 180 40 41 1080 ADMIN 213 1 20 + 20 1 R X-RAY CONTROL RM 720 42 43 SPARE 1 20 + 20 1 R X-RAY ROOM RECEPT. 540 44 45 790 E + 20 1 R X-RAY ROOM RECEPT. 360 46 3-#12, 1/2��C 47 790 E FB-1 3 20 + E 1120 48 1-1/2��C 49 790 E + 20 3 E FB-4 1120 50 2"C 51 1120 E + E 1120 52 2-1/2��C 53 1120 E FB-2 3 20 + E 4000 54 55 1120 E + 50 3 E WH-1 4000 56 2-$�2/0,#4GRD.2��C 57 1150 E + E 4000 58 59 1150 E FB-3 3 20 + 20 1 R BREAK ROOM 225 540 60 61 1150 E + 20 1 A MICROWAVE 1000 62 TD��MMC-2�� 63 1120 E + 20 1 L LIGHTING 958 64 ss ��zo E FB-5 s zo + E sso ss FINISH CEILING 67 1120 E + 20 3 E FB-6 580 68 69 580 E + E 580 70 O Project Information 71 580 E FB-7 + 20 1 SPARE 72 73 580 E + 20 1 SPARE �4 X-RAY IN-USE 75 SPACE + 20 1 SPARE 76 LIGHT 77 SPACE + SPACE 78 79 SPACE + SPACE 80 LOADTYPE PANELTOTAL FEEDTHRU SUBFEED FEEDER DEMAND FEEDERTOTAL GENERALNOTES: ♦ ail TOTAL TOTAL SUBTOTAL A (L)LIGHTING 3459 3459 125% 4324 B. �� (R)RECEPTACLES 23400 23400 NEC 220 16700 C. O 1 2 V a 11 e y (LM��ARGESTMOTOR 1440 �44� 25% 360 D. (M)MOTORS(ALL) 1664 �664 100% 1664 E. � (E�EQUIPMENT 35260 35260 100% 35260 SPECIFICNOTES: 13 o Medlcal (A)APPLIANCES 4600 4600 0 4600 (1) 5, PANEL TOTAL(KVA): 62.9 �2� 42„ O O �3� Center PANEL TOTAL(A): 175 �5� 24" 24" �$,� Q FINISHED FLOOR -� U J Q N FLAG NOTES: Vail Summit � O6 8"x8"x4"ELECTRICAL BOX FLUSH IN FINISHED 11 6"x6"x4"ELECTRICAL BOX BOTTOM OF BOX AT Orthopaed i cs � CEILING BOX TO BE ATTACHED TO WALL. 42"AFF. COVER PLATE TO CONTAIN 1 EACH 1-1/4' o TWO SCREW CABLE CLAMP CENTERED IN COVER. O7 3-12"x10"ELECTRICAL WALL DUCT FLUSH IN WALL, o EXTENDING FROM FLOOR TO 12"ABOVE FINISHED 12 PROVIDE 150 AMP,2-POLE ENCLOSED CIRCUIT � CEILING. COVER PLATE TO CONTAIN 2 EACH 2-1/2" BREAKER FOR POWER LINE. MOUNT AT 5'AFF TO US Bank Building � CLOSE NIPPLES 24"ABOVE FINISHED FLOOR. CENTER. Suite 206 X O8 12"x12"x4"ELECTRICAL JUNCTION BOX. BOTTOM OF �3 6"x6"x4"ELECTRICAL BOX. BOTTOM OF THE BOX AT ; BOX AT 18"AFF. LEAVE 6'WIRETAILS IN BOX. EC TO +24". COVER PLATE TO CONTAIN 1 EACH 1-1/4"TWO � CONNECT POWER LINE TO X-RAY POWER CABINET SCREW CABLE CLAMP CENTERED IN COVER. �OH SOUtII FrOCltag2 ROaCI � AFTER IT IS SET IN PLACE. VaII, Colorado 81657 >, m � a� a Sheet Information X-RAY EQUIPMENT PATHWAY DIAGRAM � NO SCALE Sheet Title: m OO ELECTRICAL w � � M DIAGRAMS � � � � � � � � N � 7 � U 3 � CD/PERMIT 03/03/2014 � � Sheet Number: � � � � U O U X � � � (9 U � DPA Project: 14901.00.000 ? COPYRIGHT 2013-DAVIS PARTNERSHIP,P.C. U