HomeMy WebLinkAboutB14-0075 REScheck T�� � -aa7s
REScheck Software Version 4.5.0
Compliance Certificate
Project Kent & Mary Johnson Project
Energy Code: 2012 IECC
Location: Vail, Colorado
Construction Type: Single-family
Project Type: Addition
Climate Zone: 6 (9248 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
4238 Nugget Lane Kent& Mary Johnson Michaei Rookey
Vail, CO 81657 4238 Nugget Lane Blueprint Construction CO LLC
Vail, CO 81657 Dillon, CO 80435
303-808-7511 970-333-1119
KentlJohnson@aol.com MikeBPC.lIc@gmail.com
. . . ..- .
Complian�e: O.5%Better Than Code Maximum UA: 620 Your UA: 617
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
- . .
Ceiling 1: Cathedral Ceiling 814 49.0 0.0 0.022 18
Ceiling 2: Cathedral Ceiling 744 49.0 0.0 0.022 16
Wall 1:Wood Frame, 16"o.c. 130 21.0 0.0 0.057 3
Door 2: Glass 80 0320 26
Wall 2: Wood Frame, 16" o.c. 308 21.0 0.0 0.057 17
Window 1: Wood Frame:Double Pane with Low-E 7 0.320 2
Window 3:Wood Frame:Double Pane with Low-E 7 0.320 2
Wall 3: Wood Frame, 16" o.c. 261 21.0 0.0 0.057 8
Window 4: Wood Frame:Double Pane with Low-E 6 0.320 2
Window 5: Wood Frame:Double Pane with Low-E 30 0.320 10
Door 1: Glass 80 0.320 26
Wall 4:Wood Frame, 16" o.c. 56 21.0 0.0 0.057 3
Window 6:Wood Frame:Double Pane with Low-E 10 0320 3
Wal) 5:Wood Frame, 16" o.c. 288 21.0 0.0 0.057 14
Window 8:Wood Frame:Double Pane with Low-E 30 0.320 10
Window 16: Wood Frame:Double Pane with Low-E 9 0.320 3
Wall 6: Wood Frame, 16"o.c. 336 21.0 0.0 0.057 17
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 1 of 9
�'' - . .
Window 7: Wood Frame:Double Pane with Low-E 10 0.320 3
Door 3: Solid 21 0.320 7
Wall 7:Wood Frame, 16" o.c. 288 21.0 0.0 0.057 12
Window 9: Wood Frame:Do�ble Pane with Low-E 15 0320 5
Window 10: Wood Frame:Double Pane with Low-E 15 0.320 5
Window 10: Wood Frame:Double Pane with low-E 28 0320 9
Window 11: Wood Frame:Double Pane with Low-E 28 0320 9
Wall 8: Wood Frame, 16" o.c. 70 21.0 0.0 0.057 4
Wall 9: Wood Frame, 16"o.c. 60 0.0 0.0 0.238 5
Window 12: Wood Frame:Double Pane with Low-E 5 0.320 2
Door 4: Glass 35 0.320 11
Wall 10: Wood Frame, 16" o.c. 120 0.0 0.0 0.238 20
Window 13: Wood Frame:Double Pane with Low-E 36 0.320 12
Basement Wall 1: Solid Concrete or Masonry 130 21.0 10.0 0.044 5
Wall height: 9.0'
Depth below grade: 4.0'
Insulation depth: 8.0'
Window 14:Wood Frame:Double Pane with Low-E 18 0320 6
Basement Wall 2: Solid Concrete or Masonry 216 21.0 0.0 0.052 6
Wall height: 9.0'
Depth below grade: 4.0'
Insulation depth: 9.0'
Door 5:Solid 96 0.097 9
Basement Wail 3: Solid Concrete or Masonry 504 21.0 10.0 0.034 16
Wall height: 9.0'
Depth below grade: 4.0'
Insulation depth: 9.0'
Window 15:Wood Frame:Double Pane with Low-E 23 0320 7
Door 6: Solid 21 0.097 2
Basement Wall 4: Solid Concrete or Masonry 240 21.0 10.0 0.027 6
Wall height: 10.0'
Depth below grade: 10.0'
insulation depth: 10.0'
Basement Wall 5: Solid Concrete or Masonry 60 21.0 10.0 0.027 2
Wall height: 10.0'
Depth below grade: 10.0'
Insulation depth: 10.0'
Floor 1: Slab-On-Grade:Heated 400 10.0 0.684 274
Insulation depth:4.0'
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2012 IECC requirements in
REScheck Version 4.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Name-Title Signature Date
�
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent & Mary.rck Page 2 of 9
REScheck Software Version 4.5.0
Inspection Checklist
Energy Code: 2012 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Pians Verified Field Verified
# Pre-inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID __ ___
— -____ ----- ------
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PRl]i energy code compliance for the
,�� building envelope. ❑Not Observable
❑Not Appiicable
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]� lighting and mechanical systems. ❑Not Observable
,�, Systems serving multiple ❑Not Applicable
- dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
_ -------- ---- --
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement wil)be met.
403.6 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Coolin Coolin
Manual J or other methods g' 9� ❑Not Observable
approved by the code official. Btu/hr Btu/hr ❑Not Applicable
� Additional Comments/Assumptions:
�"^�'
1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent & Mary.rck Page 3 of 9
Section Plans Verified Field Verified
# Foundation Inspection Value Value Compiies? Comments/Assumptions
& Req.ID ---—---- --- -
402.1.1 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
d. [FO1]1 � Unheated ❑ Unheated ❑Does Not table forvalues.
;_y,� ❑ Heated ❑ Heated ❑Not Observable
❑Not Applicable
303.2, Siab edge insulation installed per ❑Complies Requirement will be met.
402.2.9 manufacturer's instructions. ❑Does Not
[F02]� ❑Not Observable
,N�
❑Not Applicable
402.1.1 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies
[F03]1 depth/length. ❑Does Not table for values.
:�� ❑Not Observable
❑Not Applicable
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope assembiies
[F04]1 insulation R-value.Where interior R_ R_ ❑Does Not table for values.
,�, insulation is used,verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
- - _ _ -—
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[F05]1 insulation installed per ❑Does Not
�, manufacturer's instructions.
❑Not Observable
❑Not Applicable
— __. __ ___ .___
402.2.8 Conditioned basement wall ft ft ❑Complies See the Envelope Assemb�ies
[F0611 insulation depth of burial or ❑Does Not table for values.
�, distance from top of wall.
❑Not Observable
❑Not Applicable
_ ____ _ - —
303.2.1 A protective covering is installed ❑Complies Requirement wiil be met.
[F011]z to protect exposed exterior ❑Does Not
insulation and extends a
'- minimum of 6 in, below grade. ❑Not Observable
❑Not Applicable
__ _---- _ __ . --__ _ - ---- -
,403.8 Snow-and ice-melting system ❑Complies Requirement will be met.
[F012]z controls installed. ❑Does Not
_ ❑Not Observab�e
( __�Not Applicable
Additional Comments/Assumptions:
�
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent & Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 4 of 9
Section Plans Verified Field Verified
# Framing/Rough-In inspection Value Value Complies? Comments/Assumptions
& Req.ID -_ -- - --
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not tabie for values.
[FRl]1 ❑Not Observable
'�� ❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the EnvelopeAssemblies
402.3.1, average). ❑Does Not table forvalues.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2]1
��
303.1.3 U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
�, with the NFRC test procedure or
taken from the defauit table. ❑Not Observable
❑Not Applicable
----__ _ ____ _.__ __ _
402.4.1.1 Air barrier and thermai barrier ❑Complies Requirement will be met.
[FR23]i instailed per manufacturer's ❑Does Not
instructions.
❑Not Observabie
❑Not Applicable
- ------------- ----
402.4.3 Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]� is listed and labeled as meeting ❑Does Not
,�, AAMA/WDMA/CSA 101/1.5.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
_- ------ — -- --------------------------- - ---- -- —
!402.4.4 IC-rated recessed lighting fixtures ❑Complies Requirement will be met.
'[FR16�z sealed at housing/interior finish ❑Does Not
�, and labeled to indicate <_2.0 cfm ❑Not Observable
leakage at 75 Pa.
❑Not Applicable
-- ------------ -
403.2.1 Supply ducts in attics are R- R- ❑Complies Requirement will be met.
�`° [FR12]� insulated to >_R-8.All other ducts R_ R_ ❑Does Not
�e� in unconditioned spaces or
outside the buiiding envelope are ❑Not Observable
insulated to >_R-6. ❑Not Applicab�e
— - _ __ _ — --
403.2.2 All joints and seams of air ducts, �Compiies Requirement wi�l be met.
[FR13]1 air handlers, and filter boxes are ❑Does Not
,�� sealed.
❑Not Observable
❑Not Applicabie
--- __ -- -- ----
403.2.3 Building cavities are not used as ❑Complies Requirement wiil be met.
[FR15]3 ducts or plenums. ❑Does Not
{_d,� ❑Not Observable '
❑Not Applicable
__----- ----- ----------------------- — --
403.3 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met.
;[FR17]z above 105°F or chilled fluids ❑Does Not
I below 55°F are insulated to ?R-
_ 3 ❑Not Observable
____ — - _
❑Not Applicable
403.3.1 Protection of insulation on HVAC ❑Complies Exception: Requirement is
[FR24]z piping. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
___ _------ ---_- --------------
403.4.2 Hot water pipes are insulated to R- R- ❑Complies Requirement wiil be met.
;[FR18]2 >_R-3. ❑Does Not
� d� ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 5 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID _____ _ __ —
403.5 Automatic or gravity dampers are ❑Complies Requirement will be met.
i[FR19)2 installed on all outdoor air ❑Does Not
i intakes and exhausts. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
�
�
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 6 of 9
Section plans Verified Field Verified
& Re �p! �nsulation Inspection Value Value — Complies? Comments/Assumptions
p' ----- -------------- ---�
—_ _.
�303.1 All installed insulation is labeled Complies Requirement will be met.
�[IN13]� or the installed R-values ❑Does Not
; provided. ❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the EnvelopeAssemblies
402.2.5, mass wall with at least�/�of the � Wood ❑ Wood �Does Not table for values.
402.2.6 wall insulation on the wall � Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
�, requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable
_ _ __ _._____ ____ -- - ---- —
303,2 Wall insulation is installed per ❑Complies Requirement will be met.
[IN4]' manufacturer's instructions. ❑Does Not
;�� ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
�
�
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 7 of 9
Section plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID _..- - --- ----
402.1,1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, � Wood ❑ Wood ❑Does Not table for values.
402.2.2. � Steel ❑ Steel ❑Not Observable
402.2.6
[FI1]i ❑Not Appiicabie
,N�
- ---- __ ___ __.__ __ -
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[F12]i Blown insulation marked every ❑Not Observable
�y�� 300 ftz.
❑Not Applicable
__ ---- --- ---_ ___ --__ --._- ----_ _ _
!402.2.3 Vented attics with air permeable ❑Complies Requirement will be met.
'[F122jz insulation include baffle adjacent ❑Does Not
i to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
-- _ _ .___ ._- -
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[F13]' insulation �R-value of the ❑Does Not
`�, adjacent assemb�y. ❑Not Observable
❑Not Applicabie
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met.
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
�� <=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
_ ___---------- -- _-- --
402.4.2 Wood-burning fireplaces have ❑Complies Exception: Requirement is
�[Fi8lz tight fitting flue dampers and ❑Does Not not applicable.
outdoor air for combustion.
❑Not Observable
❑Not Applicable
--- --. _._._.- -----
403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Requirement will be met.
[F14]1 cfmI100 ft2 across the system or ft2 ft2 ❑Does Not
`� <=3 cfm/100 ft2 without air ❑Not Observable
handler @ 25 Pa.For rough-in
tests,verification may need to ❑Not Appiicable
occur during Framing Inspection.
___- - - -_ _ — - -
403.2.2.1 Air handier leakage designated ❑Complies Exception: Requirement is
[FI24]1 by manufacturer at<=2%of ❑Does Not not applicable.
design air flow.
❑Not Observable
❑Not Applicable
--- - - _ ____ _-------
403.1.1 Programmable thermostats ❑Complies Exception: Requirement is
;[FI9]2 installed on forced air fumaces. ❑Does Not not applicable.
❑Not Observable
❑Not Applitable
_ _.. _.-_ ___. _._ __-- —
C4031.2 Heat pump thermostat installed ❑Complies Exception: Requirement is
[FI10]z on heat pumps. ❑Does Not not applicabie.
' ❑Not Observable
❑Not Applicable
__--- __ _- __ _ ------------ —
'403.4.1 Circulating service hot water ❑Complies Exception: Requirement is
',[FI11I� systems have automatic or ❑Does Not not applicable.
' accessible manuai controls. ❑Not Observable
❑Not Applicable
_...__- ---- _.__._. ---- -_.__ _._ _._..___--- ------- --
',403 5.1 All mechanica�ventilation system ❑Complies Exception: Requirement is
;[FI25]z fans not part of tested and listed ❑Does Not not applicable.
HVAC equipment meet efficacy
� and air flow limits. �Not Observable
Y`_____� ❑Not Appiicable
.�w►
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 8 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions � Value Value Complies? Comments/Assumptions
& Req.ID
--- --.__. . __---- .----- —
403.9.1 Readily accessib�e switch on ❑Complies Exception: Requirement is
[Fi12]3 heaters for swimming pools or ❑Does Not not applicable.
�, permanent in-ground spas. ❑Not Observable
❑Not Applicable
-- ___._._. - ___
403.9.2 Timer switches on heaters and ❑Complies Exception: Requirement is
[FI19]3 pumps serving pools and ❑Does Not not applicable.
�, permanent spas. ❑Not Observable
❑Not Applicable
__ ___.__ ____. _..._...._.. --_--- -.---.--.._._.._ ---
403.9.3 Heated pools and permanent ❑Complies Exception: Requirement is
[F120]3 spas have a vapor retardant ❑Does Not not applicable.
�� cover. ❑Not Observable
❑Not Applicable
_ ____. ____ ---
404.1 75%of lamps in permanent ❑Complies Requirement will be met.
[F16]1 fixtures or 75%of permanent ❑Does Not
`�� fixtures have high efficacy lamps. ❑Not Observable
- Does not apply to low-voltage
lighting. ❑Not Applicable
-- ------ - --—- - --
404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
_------- _.__-- - --_.... _---- - —
I401.3 Compfiance certificate posted. ❑Complies Requirement will be met.
[FI7�� �Does Not
❑Not Observable
❑Not Applicable
- --------- ---- _ _ -------------
303.3 Manufacturer manuals for ❑Complies Requirement will be met.
[Fi18]3 mechanical and water heating ❑Does Not
�, systems have been provided. ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
�.r..
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Kent& Mary Johnson Project Report date: 03/30/14
Data filename: C:\Users\Mike\Desktop\Res Kent& Mary.rck Page 9 of 9
2012 IECC Energy
Efficiency Certificate
. .
Wall 21.00
Floor 31.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
�.. . •
Window 0.32
Door 0.10
. .. . .
Heating System:
Cooling System:
Water Heater•
Name• Date:
Comments
�
�