Loading...
HomeMy WebLinkAboutA14-0010 DATA SHEETS Security Standard features Overview Expandable to 192 fully programmable hardwire The NetworX NX-8E is a full-featured security system and/or wireless zones that uses advanced technology for burglary, fire and • 240 user codes environmental detection. The NX-8E is a flexible security system that is both easy to install and simple to use. R Up to 192 addressable devices can be used With eight partitions and up to 192 zones, the NX-8E can � 512-event history log that provides date, time, event handle your most demanding commercial and and user number residential security needs. Up to 8 true partitions with separate account codes, Outstanding features entry/exit delays, and feature selections for each partition The NX-8E panel comes standard with eight hardwire � Maximum of 32 keypads with up to 8 per partition zone inputs and two relays. Four programmable outputs can be set up to activate external devices during an Wireless technology with up to 192 supervised zones alarm or other system event. The modular design allows � 2-wire or 4-wire smoke detector compability for complete integration of multiple systems within one • Fire alarm verification for greater false alarm immunity enclosure. Adding more zones or expanding capability is fast and easy. < Dynamic battery test _ • Standard RS-232 on-board interface Convenient and flexible Conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with the DL-900 software for Windows. NetworX Control Panel N X-8 E - ��� �`�- -_ �. ��� 5,.. � � �l� ��]YI�_• '��+�IJF�� � � �cr qe � °rr � � � !�f� � � � � � Security NetworX Control Panel NX-8E Available Keypad Styles Specifications • Operating Power - 16.SV AC 40VA � � Auxiliary w/40VA or 50VA transformer - 2 Amp • Auxiliary w/NX-320E power supply - 3 Amps* N I ' Loop resistance �' For standard loop - 30052 Maximum For 2-wire smokes - 3052 Maximum LED with LCD with Operating temperature Removable Door Removable Door 32° to 120°F Dimensions � 6.40 inches wide �i�! � � 4.0 inches high �� � �— 0 1.10 inches deep � I Shipping weight � �' 9 pounds Fixed Display with LED with *When using the NX-320E Iw/SOVA transformer)rated at 2 Amps and NX-SE Removable Door Removable Door Iw/40VA or SOVA transformerl rated at 1 Amp,the combined available power is 3 Amps. Customer Service and Technical Support: 1-888-GE Security (437-3287) 12345 SW Leveton Drive Tualatin,OR 97062 Phone:503-692-4052 USA&Canada:800-547-2556 www.gesecurity.com / i � imagination at work OO 2005 GE Security. NetworX is a trademark of GE Security All other trademarks are properties of their owners. 466-2134-KA-0105 NetworX NX-148E-RF touchpad Secu rity The NX-148E-RF is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to-read, customizable display. It is compatible with all NetworX control panels (except commercial fire). The NX-148E-RF offers the are also five pre-programmed touch Features convenience of having an integrated keys that allow the most common wireless receiver built into the keypad functions to be performed with ease. • Integrated 48-zone wireless along with standard hardwire features. All keys on the NX-148E-RF are backlit receiver A removable door allows the user to ensure error-free operation—even . Optimize wireless reception by to swing the door down or simply in a dark room. having the keypad/receiver in the take it off for use.The NX-148E-RF The NX-148E-RF is cost-effective best location emergency keys are highlighted on and easy to install. Designed for • LCD, easy-to-read programmable the keypad and can be programmed functionality and compatibility,the NX- display to contact and send complete 148E-RF is the right keypad to fit any information to a responding police,fire application. • Traditional design to go with any or EMS unit with just one touch.There decor • Compatible with all NetworX series control panels (except commercial fire) N etwo rX N X- 148 E— I \ � ' Easy to install, program and maintain wireless �CD display keypad � _ _ �,. . . .. . ._�.. , �� . ��I 11 ��r��� ���:�ar�j �� Armed Reatly Fire Power � � � o 6"�-r - - ��"�" - �.;'„:: ,:_ �r_� - ��;�� �. � � � � , / / ' S ecifications p Americas Electrical Ordering information 503-885-5700 •Current:75 to 110 mA nominal NX-148E-RF NetworX 48-zone LCD display 888-GE-SECURITY Environmental keypad with door and integrated (437-3287) .Operating temperature:32 to 120°F(0 to 49°C) wireless receiver faxback 800-483-2495 PhySlCql info@gesecurity.com . Dimensions(HxWxDI:5.30 x 6.20 x 1.30 in.(135 x www.gesecurity.com 157 x 33 mm) •Construction:ABS plastic Asia •Color:White te1852-2907-8108 fax 852-2142-5063 Australia tel 61-3-9259-4700 fax 61-3-9259-4799 Europe tel 32-2-725-11-20 fax 32-2-721-86-13 Latin America te1305-593-4301 fax305-593-4300 O 2006 GE Security. As a company of innovation,GE Security reserves the right to change product specifications without notice.For the latest product specifications,visit GE Security online at www.GESecurity.com or contact your GE Security sales representative. 20060322 DS nx-148e-rf 466-70.B •i, L V L P R 0 D U C T I N F 0 R M A T I 0 N B U L L E T I N � � .;.; . . 449 / 448 SERIES ,;;.,.:. ,. � f �f��' _ � �� Self-Diagnostic, Four- ��:f, _ . � � � R�� ` � Wire, Photoelectric ���i�: _ � ,� �{� .�:-v �� ,f,�,:�r f,���.�� Smoke Detectors fas: _ Model numbers: 449AT,449C,449CT,449CRT,449CST,449CSTE, � , 449CSRT,449CSRH,449CTE -•. -Y., � _.:.��;: :. �.�_.. : o L F M U LC :� � LISTED APPROVED _;f � .r - -;;•r,��=r-� California State Fire Marshal Approved MEA(New York City)Approved ULC model numbers: 448AT,448C,448CT,448CST,448CSRH,448CTE • Intelligent, self-diagnostics The ESL 449/448 Series self-diagnostic, four-wire smoke detectors continually monitor their own • On-site maintenance alert sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity • Field replaceable optical chamber range orfail internal diagnostics. This unique, • Low-p rof i l e d esi g n patented technology meets N FPA 72 field sensitivity testing requirements without the need for external • Plug-in terminal block meters. Additional diagnostic information is activated by • Advanced false alarm immunity applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL's proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate-of-rise and fixed 135°F (57°C), 50-foot rated, heat sensor is available with all "T" model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non-latching sounder (local alarm) for smoke, making it ideal for motel/hotel and dormitory rooms where smoking is permitted. continued ESL 449 Series Sl�noke Detectors Architectural and Engineering Specifications The ESL 449 Series low-profile, self-diagnostic,four-wire The proprietary optical sensing chamber is field replaceable, smoke detectors work on the light scattering principle.A allowing quick and easy cleaning and maintenance. pulsed infrared light-emitting diode serves as the light source, Models with auxiliary relays are approved for releasing and a high-speed photodiode as the sensing element. When service. the amount of light reflected onto the photodiode reaches the This low profile product is equipped with a hinged cover, a sensitivity setting,the smoke sampling rate increases. Three concealed tamper-resistant latch, and insect screens. (3)successive smoke sensings above the sensitivity setting Wiring terminates in plug-in, clamp-type screw terminals. are required to sound an alarm.This design has superior Detectors mount to a standard single-gang electrical box, a protection against false alarms caused by dust, insects, RF four-inch octagonal,four-inch square electrical box, or and ambient-light. WIREMOLD 5739 fixture box. A confirmed alarm causes the normally flashing power Smoke Detector Spacing indicator LED to light continuously and the alarm relay to On smooth ceilings(as defined in NFPA 72),spacing of 30 feet operate. A trouble indication is automatically displayed by (g.1 meters)may be used as a guide. Other spacing may be used flashing the LED every second. This meets NFPA 72 field depending on ceiling height,high air movement,and other sensitivity testing requirements. An internal 85 dB horn conditions or response requirements. (available in"S" models)emits a temporal 3 when the detector alarms and a steady tone when power polarity is t reversed. ,.85•�4���m,� 6.,•�,5.5�m) — � I 1 �—0 — Product Data Sensitivit 3.1 - 1.0%/ft. max. -CST..........................................................................40mA y................................................. ( ) 3.1 +0.50%/ft. (min) -CSRT, CSRH, CSTE................................................51 mA Operating temp. range ............... 32°F to 120°F(0°C to 50°C) Typical avg. polarity reverse current Operating humidity range....................................0 to 95% RH -CST, CSRT, CSTE, and CSRH................................10mA Minimum voltage-C, CT, CRT, CST, CSRT, CSRH , Sounder specifications.........................................85 dB at 10' -CSTE.........................................................................8.5V Heat detector specifications -AT..............................................................................5.1V -fixed temperature ..................................... 135°F(57.2°C) Maximum voltage-C, CT, CRT, CST, CSRT, CSRH, -rate of rise .... 15°F/min. &>105°F(8.3°C/min. &>40.6°C) -CSTE...........................................................................33V Auxiliary relay contacts 2A @ 28 VDC or 120 VAC (resistive) -AT................................................................................27V Alarm contacts ........................ 500 mA @ 36 VDC(resistive) Maximum ripple(peak to peak)........................................ 10% Field wiring size.................................................. 14-24 AWG Typical average standby current.....................................70aA Packaging .......................10 detectors are packed in a carton -CSTE........................................................................23mA Color....................................................white cover/white base Typical alarm current-C, CT and AT ............................ 15mA with UV inhibitor to prevent yellowing -CRT..........................................................................31 mA Listin UL 268, ULC FM, CSFM and MEA g.............................. Selection Guide Designator Feature Description H Isolated Fixed Temp. Isolated fixed 135°F(57°C)and rate of rise heat detector,independently trips the LED and alarm and Rate of Rise output.Smoke detector activates intemal sounder(local alarm)and auxiliary relay,but Heat Detector does not latch.Approved as both single station smoke alarm and system heat detector. Ideal for hotel,motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall,door holders,strobes,etc.Listed for releasing service. S Built-in Sounder 85dB built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated Fixed Intergrated Fixed 135°F(57°C)temperature and rate of rise heat detector. Temp.and Rate of Either heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detector relay outputs. E Built-in end of line Relay is normally energized and will trip with loss of power.Can also provide notification power supervision relay when detector needs maintenance. in t e r I o g i►i•.. PH�3.692.�5Z ��,������x.��� US4 8 Canada: 800.547.2556 Irnerlogix,Cadd�c,H,lil and�trol aretraAmiarksof Technical Service: 800.6487424 FaxBack:800.4832495 irnenogix,inc w�vw.sentrd.wrn www.ir�eaiogi�csearity.mm E-3965 Rev B-1101 �� SYSTEM � ��� SENSOR° �` -___.� � , '� BI 5600 Series Mechanical � ` Heat Detectors ��� � � + _� � . _ ...s. � � �, System Sensor's 5600 series mechanical heat detectors '� offer a low-cost means for property protection against ; � � fire, and for non-life-safety installations where smoke �` � ,,� detectors are inappropriate. `__ ?�,������� �':-` - , Features Multiple configurations.The 5600 series offers a full-line of •Multiple configurations for installations configurations to accommodate a broad range of applications.Both —Single-and dual-circuit models single-and dual-circuit models are available for low-and high- —Fixed temp and combination fixed-temp/rate-of-rise temperature ratings with either fixed temperature or combination 135°F or 194°F ratings. fixed temperature/rate-of-rise(ROR)activation.The ROR element of the fixed/ROR models is restorable to accommodate field-testing. •Plain housing for residential installations(Model 5601 P) •Easy-to use terminal screws Installation flexibility.To satisfy a variety of installation needs, •A broad range of back box mounting options: the 5600 series easily mounts to single-gang and octagonal back —Single gang boxes.And these models accommodate four-square back boxes, —3.5""and 4"Octagonal when used with a square to round plaster ring.The reversible —4""square with square to round plaster ring mounting bracket permits both flush-and surface-mount back box installations. •Reversible mounting bracket Visual identification.The 5600 series provides dear markings on the exterior of the unit to ensure that the proper detector is being used.Alphanumeric characters identify the activation method,as well as the temperature rating,in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX,while combination fixed/rate of-rise units are marked FX/ROR.The 5600 series also provides a post-activation indicator in the form of a collector.When the detector is activated,the collector drops from the unit,making it easy to identify the unit in alarm. Agency Listings � u� F M MEA «(�� a roved ��'°°'° LISTED APPROVED pp s_,oi io,aoce i.�-os-e ;zio-;zo���zz, Specifications Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems.The detector shall be either a single circuit or a dual-circuit type,normally open.The detector shall be rated for activation at either 135°F(57°C)or 194°F(90°C),and shall activate by means of a fixed temperature thermal sensor,or a combination fixed temperature/rate-of-rise thermal sensor. The rate of rise element shall be activated by a rapid rise in temperature,approximately 15°F(83°C)per minute.The detector shall indude a reversible mounting bracket for mounting to 3'/z-inch and 4-inch octagonal,single gang,and 4-inch square back boxes with a square to round plaster ring.Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire.The detector shall contain alphanumeric markings on the exterlor of the housing to identify its temperature rating and activation method.The rate of rise element of combination fixed temperature/rate of rise models shall be restorable,to allow for field-testing.The detectors shall indude an external collector that shall drop upon activation to identify the unit in alarm. •. Maximum Installation Temperature 5601 P,5603,5621,and 5623:100°F(38°C) 5602,5604,5622,and 5624:150°F(65.6°Q Operating Humidity Range 5 to 95%RH non-condensing Dimensions with mounting bracket Diameter:4.57 inches(11.6cm) Height: 1.69 inches(43cm) Alarm Temperature 5601 P,5603,5621,and 5623:135°F(57°C) 5602,5604,5622,and 5624:194°F(90°C) Weight 6 oz(170 grams) Rate-of-RiseThreshold 15°F(83°Q rise per minute(models 5601 P,5602,5621,and 5622 only) Mounting 3Yrinch octagonal back box 4 inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring . . Operating Voltage/Contact Ratings 6-125VAC/3A 6-28VDC/1 A 125VDC/03A 250VDC/O.IA InputTerminals 14-22 AWG eoai� xi xi aoaixi O O O O O �4� � � o � � i � i- � 5607P 5602,5622 5603,5623 5604,5624 5621 Ordering Information - - � 5601 P Single None 135°F(57°C) Fixed Temperature/Rate of Rise 50 feet x 50 feet(15.24m x 15.2m) 5602 Single Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5603 Single Lettering 135°F(57°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5604 Single Lettering 194°F(90°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5621 Dual Lettering 135°F(57°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 152m) 5622 Dual Lettering 194°F(90°C) Fixed Temperature/Rate-of-Rise 50 feet x 50 feet(1524m x 15Zm) 5623 Dual Lettering 135°F(57°C) Fixed Temperature 25 feet x 25 feet(7.62m x 7.62m) 5624 Dual Lettering 194°F(90°Q Fixed Temperature 25 feet x 25 feet(7.62m x 7b2m) *NOTE:Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. l\��� �\��� �ZOCE �_tc n Sen� �� �� 3825 Ohio Avenue•St.Charles,IL 60174 ��a��rspe<�fi��o�ss�u,��<<o�rz ge �mou�,���<e.u�s��sys�emsenso�-�omro� ��� �����R� PhOIl2:80�-SENS�RZ•FdX:63�-3��-6495 currenrproduainformation,�mdudingthelares[verslonofthlsdatasheet. A05-0351-002•11/06•i31676 �� SYSTEM _ . ,y _ ,_ , _ ��� SENSOR° � ��;:��� � . � * C01224T Carbon Monoxide � �� Detector ,� with RealTestTmTechnology � ,�,;�� i � .�� � � The System Sensor C01224T CO detector provides early - � _� �,,�: �� warning by using electrochemical sensing technology ° -� to measure carbon monoxide levels in the air. Features With RealTest`"technology,the CO gas sensing cell of the •RealTest�"technology allows installer to test detector with CO gas C01224T CO detector can be tested using a carbon monoxide gas agent Simply hold the test button for two seconds.After the alarm •Full compliance with UL 2075 cyde(temp 4)the green LED will flash about once per second, •A code required trouble relay indicating that the detector is ready to accept CO for testing. •Wiring supervision with SEMS terminals Spray a small amount of CO into the detector per the installation instructions,and within seconds the detector will alarm,indicating •A six year end-of-life timer successful gas entry. •12/24 VDC •A current draw of 20mA in standby and 40mA in alarm If dangerous amounts of carbon monoxide is detected,the C01224T detector will alert residents by sounding and flashing a temp-4 signal •Versatile mounting for wall and ceiling alarm.Protection is guaranteed 24/7 by a central station,regardless •Electrochemical sensing technology of whether residents are away from home,sleeping or already suffering from the efFects of C0. This specific device is designed for system operation.The detector is fully listed to UL 2075.It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station.It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision.The C01224T detector offers a low current draw,allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The C01224T model will operate on most industry security and fire Agency Listings alarm control panels because it is is a 12/24VDC detector. U` LISTED �o�s C01224T Carbon Monoxide Detector Specifications Carbon monoxide detector shall be a System Sensor model number C01224T,listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay.The detector's base shall be able to mount to a single-gang electrical box or direct (surface)mount to the wall or ceiling.Wiring connections shall be made by means of SEMS screws.The detector shall provide dual color LED indication,which blinks to indicate normal standby,alarm,or end-of-Iife.When the sensor supervision is in a trouble condition,the detector shall send a trouble signal to the panel.When the detector gives a trouble or end-of-life signal,the detector shall be replaced.The detector shall provide a means to test CO gas entry into the CO sensing cell.The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA(75 mA test) Alarm Contact Ratings 0.5 A@ 30 VDC Trouble Contact Ratings 0.5 A@ 30 VDC Size Length:5.1 in,Width: 33 in,Height:13 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104°F(0°C to 40°C) Operating Humidity Range 22 to 90%RH InputTerminals 14 to 22 AWG Mounting Single gang back box;surface mount to wall or ceiling Operation Modes .. - � - � Normal(standby) Blink 1 per minute — — Alarm — Blink in temp 4 pattem Sound in temp 4 pattern RealTest""Feature: The System Sensor C01�24T carbon monoxide detector with RealTest` can evaluate the functionality of the CO sensing cell using canned tcst agent. - • • <� '� _ � � \ � i ^ � � �� r � I� � �: � 0 Push and hold theTest/Hush button for Spray canned CO agent Into the detector. Verify CO sensing at the control panel.The two seconds to enter RealTest mode.The detector will automatically exit RealTest green LED will flash once every second to alarm mode after about 20 60 seconds. indicate RealTest mode has started. NOTE:Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an Installation. Hush Feature: Pushing theTest/Hush button will silence the sounder for S minutes(except in RealTest mode). Trouble Feature: When the detector is in a trouble condition,it will send a trouble signal to the panel. End of IifeTimer: After the detector's internal sensor has reached the end of its life,a trouble signal will be sent to the panel.This will indicate that it is time to replace the detector.An electrochemical carbon monoxide detector lifespan is approximately six years,and the detector must be replaced by the date marked on the inside of the product. Ordering Information �- C01224T 12/24 volt,4 wire system monitored carbon monoxide detector with RealTest""Technology �� SYSTEM ozoo8 sy,em sen=o�. w, 3825�h10 f�V2YlUe•St.�{ldY�eS,��6�174 ?roductspe6�ca�onssub�rcttorn gcwithoutnotrce.uis�sysremsensor.comfor �' �l' SE/�/SOR Ph0112:8��-SENS�RZ•FdX:63�-3��-6495 cwren[producUnfom�ation,lndudingehelacestversionofthlsdatasheet. � A05-0437-000•8/OS•H1953 / � � �� :, �� � i � WWW.�IIIt�OgIX.CqII Pi nPoi nt Addressable Fbi�t ID 9�sterrs O✓ervi ew lhe RnF�ir�addres�le sdutiais bring tog�her N�worX MC�E f�.rictia�alitywiththerdiabilityof C�Iriterlogixser�rs. ��' �pporting up to 192 devioes on a single two-wire la�p up to two �' rriles,the RnFbir�poirrt IDsdution can be ir�stalled fast in new oor�stnxtion or retrofit applicatioris. , � Components NetworX NX 8E ` Part#NX 8E ��.4�� � � "t 4 ���_ �, Pi nPoi nt �_'ti� Interface Card - ,� Part#NX-2192E �r`31. � � , -_ , AP Seri es Standard Features Motion Sensor o Single two-wire loop up to two miles means fast and easy Part#AP75QID installation for new construction or retrofit applications o Addressabl e sensors i ndi cates exact I ocati on of al arm or trouble event ShatterPro� o Supports up to 192 devi ces C�assbreak o Advanceddigital communicationfromthesensorsto Part#584.�r I D the panel . o GE I nterl ogi x—a name you know and trust o Supports 3 a ass B I oops Single Input Device Part#SI-ID 4lnput 40utput Device ' Part#41441 D � �• `�• �.�-.• - '� � ` � - AP75al D Addressabl e PI R Descri pti on Speci fi cati ons An addressable RRfa-use with the NX219`LERriparrt ID Bus �using Material Fla�re reta-dant ABS ���{�. Gperati ng voltage 8 to 27V(as supplied by f�DF2192E� CLrrent draw 250 FiA typical avg.3iri4with LID m�n�rrtarily on Features Transmit condition Alami,tarrper Detection range 50ft(15.�n) P�tive9rx�eRooessing-3Dsignalprooessingwith�iding Mountingheight 6to10ft(1.8to3m) foais rrirror optics analy�s si�,speed,shape and adapti� Number of curtai ns 7 alarmthreshold. Gperating terr�erature 32°to 131°F(0°to55°G) �I ati ve humi di ty 10%to 90%norioorider�si ng Rovides fax separate curtai n owe�-age pattems with 50' Maxi mum I i ne I ength 10,000 ft(31�n) (15.2 m)r�ge. Di mensi ons Width 2.9'(74rim) Flat wall or oorrier mourrting h�ight up to 10'(3m). Depth 2.2'(56rrm) Ships with two plastic ir�serts,�ch oo�ing half the owerage ��9ht 5.1'(129imi) pattemfa-m�-efleadblem�u�tingoptions(oentercurt�n �stings 1�639,F� always active). Coverage Patterns 50' 15.2m �� i — I� � �� ���� a 10' � ��,� �ti P 3.Om I 4J� L@ft 1 I _ a.s� q5° Ri ght 1.4m 584�I D Addressabl e Shatterpro°C�assbreak Descri pti on Speci fi cati ons An addressable ShatterF7o°II��eak for use with the Housi ng materi al Fi�ret�-dant ABS M<2192E RnF�i�t ID Bus I�terFaoe. Operati ng vol tage 8 to 27V(as suppl ied by NX 2192) Qarrent draw 250 E�A typical a�g.3rr►4with LID rrprr�rrtarily on Features Microphone Q7ru-diredion�dedret C�erati ng terrp�erature 14°to 1 ZO°F(-10°to 50°G) ShatterRo'sPattemF�oognitionTechndogy'"fors�.iperior Relativehumidity 10°/oto90%nor�oonder�sing detedion arid false alarm irrrrunity. Maxi mum I i ne I ength 10,000 ft(34an) R�ects�I gl�s types up to a starxYard tl�da�ess of 1/4" ��nsi ons (6.4 rrrn)induding plate,wired,terrpered ar�d larririated glass. Width 3.13'(80rrm) Depth 1.7'(4.'irim) �through light blirxls arid unlined drapes.Raitablefor use Height 4.2'(1Q8rrYn) i n oocupied areas on the peri meter loop. Li sti ngs Ftx � Wall mount � 0'(sm) � max. 20'(6m) o max. Ceiling mount r`=' rs'�-- /A�4 SI-IDSingle Input Device Descri pti on Specifi cati ons An adch-essable sirx�Je irput irrterfaoet000nr�ect a single Housing material Rarre retardarit ABS na�raddressable devioe to the NX2192ERnF�ir�ID Operati ng voltage 8 to 27V(as supplied fry N�2192q �i��� Si gnal i ng vol tage 4 to 9V Q.irrent draw 250µ4 operating temperature 32°to 131°F(0°to55°G) Featu res Rel ati ve humi di ty 10%to 90%�ng Maxi mum I i ne I ength 10,000 ft(31a�n) SLpports a single naraddressable clevioe. Di mensi ons Width 3.3'(84rrrn) Uili�s advarioed digital data oorrrrunicatior�s prot000l that Depth 1.3'(33rrm) ens�a-estheir�tegrityofthedataoaim.inication. Height 2.8'(11rrrr�) Li sti ngs UL 365,UL 609,UL 985, l�1023,l�161Q Ftx . ... - --.. -. . .. - To single � �-� non-addressable From PinPoint device,such as a loop O ma netic contact �,�� � 471�+5% 9ngle H1 941�+5% Double Ef'1 >2052 Short 41441 D Four I nput Four Output Devi ce Descri pti on Speci fi cati ons An addressable 4 input and 4 ur�ervised output ir�erfaoe Housi ng materi al A�ne reta�dant ABS that al loavs ynu to oonned up to 4 norradck�essable devioes Cperati ng vol tage 12 to 30�DC to the NX 2192E RnFbi rrt ID Bus Irrterfaoe. Si gnal i ng vol tage 4 to 9V Q.irrent draw 100 uA(kx.�s loading) Features Q.itput current 500rr�4 rr�drrum�ch Operati ng terr�erature 32°to 131°F(0°to 55°G) Slapports four i nputs�d four unsupervised outputs F�I ati ve Humi di ty 10%to 90%�ng (f�oms,bells,sirens,etc.). Maximum line length 10,OOOft(31a�n) Utili�sadvanoeddigitaldataoonYrunicatiaisprotoodthat a�nsions ensures the i rrtegrity of the data oorm�.x�ication. �Ni dth 6.8'(173rrm) Depth 2.0'(51rrm) Height 4.8'(122rmi) Li sti ngs U_.365,U_.609,ll 985,U_.1023,l�1610,FUC To unsupervised Addressable outputs,such as Inputs O O O horns and sirens • •�• ' ''�• -• • •. ' • �'• >1 MS2 � 0 0 0 47k�% Single B1 941�+5% Double 8:1 >2(X2 �a�t ..� �`•'' `I A��d h"_.�.;� ��I. ..�.I . . NX 2192E Descri pti on Speci fi cati ons Ft�i�t ID Bus Imerfaoe C�rd. Clarrent Draw 170 m4 standby rr�arrum C�erati ng terr�erature 32°to 122°F(0°to 50°G) Shipping Weight 0.51b. Features Di mensi ons Width 2'(51mn) Attadies to the NX-8Eoontrd panel. Depth 1.25(3�rm) �s ir�teifiaoe that supports up to 192 addressable devioes on ��9ht 9'(229rrm) a two-rrile Ic�op. 9upports three dass B loops. Ordering Information •.- �- . • . �•• . . N�8E Netwa-Xf�D�8Eoontrd panel — ll f�DF2192E RnFbi rrt i rrterfaoe c�rd — l� AP75aID Ge ir�eiia�ix AR White ll 584�ID Geirrterla,px�assbi-�k White R7C SI-ID 5rx,�e ir�xat devioe White l� 41441D 4 input 4 output deviae White ll � � C�Interlogix wvnv.CLlrrtala,yxam 123455WLe�or�LYi� �Seaa�xlStratNath Ti�atin,Q'Z97IX�7 Nath�.Pat�,MN�5109 Hte�ie:5Q3-652-41.Y�2 Fha�e.�651-7T/-2L� (,54&C�xxk�.'SCn-547-2556 (.54&C�vxx�a:SLn-777-5484 Tedmical Sertdc�:�-6487424 T�cal Servic�:8Cb-7T/-21i14 Fa�dc 8IX}4�3-24�5 �02003 C�Irrterlajx 9xnke!in a Cm is a traden�rk d C�Irrteaiajx Pll traderrnks are properties d thar w✓ne�s. M-0301-X�OO4Vi-0103