Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B11-0496 Code Compliant Assemblies approved
BOULDER PHONE: 303 449.8900 1805 29TH STREET, SUITE 2054 FAX: 303.449.3886 DENVER BOULDER COLORADO SPRINGS LAS VEGAS LAKE TAHOE BOULDER, COLORADO 80301 WWW.OZARCH.COM ® ARCHITECTURE URBAN DESIGN INTERIOR DESIGN 12.18.2013 Page 1 of 1 g:\2007\17004 lionshead inn\project management\bldg code 2009\code compliant STRATA VAIL VAIL, COLORADO CODE COMPLIANT ASSEMBLIES FOR RATED CONSTRUCTION 100% CONSTRUCTION DOCUMENTS DECEMBER 20, 2013 12/20/2013 Received By Lynne Campbell at 11:16 am, Jan 13, 2014 B11-0701 Reviewed for Code Compliance Code: 2012 International Building Code (IBC) CODE COMPLIANT ASSEMBLIES FOR RATED CONSTRUCTION Title 1 Hour Exterior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL 263 Design No. V 454 1 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL 263 Design No. U465 1 Hour Joint System/Head detail at 1 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL HW-D-0420 ES Report ESR-2012 CEMCO Slotted Steel tracks Expansion Joint System and FIRESTICK for Interior Partitions 1 Hour or 2 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL 263 Design No. U 493 1 Hour or 2 Hour Interior Bearing Wall Fire Resistant Ratings- ANSI/UL 263 Design No. V 446 2 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL 263 Design No. U411 See Fire Resistant Ratings- GA File No. WP 1522 for STC Sound of 55 -59 2 Hour Joint System/Head detail at 2 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL HW-D-0421 2 Hour Joint System/Head detail at 2 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL HW-D-0453 2 Hour Joint System/Head detail at 2 Hour Interior Non-Bearing Wall Fire Resistant Ratings- ANSI/UL HW-D-0461 2 Hour Interior Non-Bearing Wall/Shaft Wall Fire Resistant Ratings- ANSI/UL 263 Design No. U438 2 Hour Joint System/Head detail at Shaft Wall Fire Resistant Ratings- ANSI/UL HW-D-0476 & HW-D-0480 1 and 2 Hour Masonry or Concrete Wall Fire Resistant Ratings for equivalent thickness per IBC Table 721.1(2) 2 Hour Structural Steel Columns Fire Resistance Ratings- ANSI/UL 263 Design No. Y710 or Y715 2 Hour Perimeter Fire Containment System at balloon framed exterior wall (non-rated and 1 HR rating) UL Classified System No. CW-S-1021 2 Hour Perimeter Fire Containment System exterior slab edge @ 1 HR exterior non- bearing wall UL Classified System No. CW-S-0003 2 Hour Floor/Ceiling Assembly Fire Resistant Ratings- ANSI/UL 263 Design No. D779 1 Hour and 2 Hours Roof/Ceiling Assembly Fire Resistant Ratings- ANSI/UL 263 Design No. P732 THROUGH-PENETRATION FIRESTOP SYSTEMS Plumbing /Mechanical Penetrations Concrete Floors and walls Bare metallic pipe Max 3 HR System No. C-AJ-1353 Multiple metallic Pipe Max 2 HR System No. C-AJ-1361 Fiberglass insulated Pipe Max 2 HR System No. C-AJ-5138 AB/PVC Foam Insulated Pipe Max 2 HR System No. C-AJ-5155 Non-Metallic Pipe (Max 2”, No Collar) Max 2 HR System No. C-AJ-2292 Non-Metallic Pipe (2” to 4” With Collars) Max 2 HR System No. C-AJ-2298 Non-Metallic Pipe (Max 6” With Collars) Max 2 HR System No. C-AJ-2125 Multiple Mixed Penetrations Max 3 HR System No. C-AJ-8093 Framed Gyp Walls Bare metallic pipe 1&2 HR System No. W-L-1222 Bare metallic pipe 1&2 HR System No. W-L-1223 Multiple metallic Pipe 1&2 HR System No. W-L-1168 Fiberglass insulated Pipe 1&2 HR System No. W-L-5121 AB/PVC Foam Insulated Pipe 1&2 HR System No. W-L-5122 Non-Metallic Pipe (Max 2” No Collar) 1&2 HR System No. W-L-2241 Non-Metallic Pipe (2” to 4” With Collars) 1&2 HR System No. W-L-2237 Non-Metallic Pipe (Max 6” With Collars) 1&2 HR System No. W-L-2074 Multiple Mixed Penetrations 1&2 HR System No. W-L-8026 Electrical Penetrations Concrete Floors and Walls Single Conduit Max 3 HR System No. C-AJ-1353 Multiple Metallic Conduits Max 2 HR System No. C-AJ-1354 Bus Ducts Max 3 HR System No. C-AJ-6008 Bus Ducts Max 3 HR System No. C-AJ-6019 Multiple Mixed Penetrations Max 3 HR System No. C-AJ-8093 Framed Gyp Walls Single Conduit 1&2 HR System No. W-L-1222 Single Conduit 1&2 HR System No. W-L-1223 Multiple Metallic Conduits 1&2 HR System No. W-L-1224 Multiple Metallic Conduits 1&2 HR System No. W-L-1168 Bus Ducts 1&2 HR System No. W-L-6001 Bus Ducts 1&2 HR System No. W-L-6005 Multiple Mixed Penetrations 1&2 HR System No. W-L-8026 Electrical Boxes 1&2 HR Guideinfo CLIV Data-Com and High Traffic Openings Concrete Floors and Walls Cable Bundle-single EZ-Path (100% Fill) Max 4HR System No. C-AJ-3214 Cable Bundle - 3 Ganged EZ-Path (100% Fill) Floors only Max 4 HR System No. F-A-3015 Cable Bundle - Single EZ-Path (100% Fill) Walls only Max 2 HR System No. W-J-3099 Cable Bundle - 3Ganged EZ-Path (100% Fill) Walls only Max 4 HR System No. W-J-3098 Cable Bundle (34% Fill) Max 2 HR System No. C-AJ-3177 Cable Bundle (48% Fill) Walls Only Max 2 HR System No. W-J-3043 Multiple Mixed Penetrations Max 3 HR System No. C-AJ-8093 Framed Gyp Walls Cable Bundle - Single EZ-Path (100% Fill) Walls only 1&2 HR System No. W-L-3219 Cable Bundle-3Ganged EZ-Path (100% Fill) Walls only 1,2,3,&4 HR System No. W-L-3218 Cable Bundle (4.5” Dia) 1&2 HR System No. W-L-3169 Cable Bundle (4.5” Dia) 1&2 HR System No. W-L-3170 Cable Bundle (48% Fill) Walls Only 1&2 HR System No. W-L-3132 Multiple Mixed Penetrations 1&2 HR System No. W-L-8026