HomeMy WebLinkAboutB14-0110 plans APPROVED04/15/2014
04
/
1
5
/
2
0
1
4
Fixture TypeLamp TypeQuantityFixture TypeLamp TypeQuantity VINCANDESCENT4DLED5 F FLUORESCENT1 TTRACK LED6 PINCANDESCENT2 CCHANDELIER1 Incandescent Total:4High-Efficacy Total:15 Percent High-Efficacy:78.95%(must be minimum of 75%)FIXTURE SELECTION BY OWNERIncandescent FixturesHigh Efficacy FixturesIECC 2012 CALCULATION
PR
O
J
E
C
T
:
A
N
T
L
E
R
S
U
N
I
T
1
0
9
R
E
M
O
D
E
L
E
N
G
I
N
E
E
R
:
S
O
H
PR
O
J
E
C
T
#
:
1
4
0
2
5
VO
L
T
A
G
E
:
1
2
0
/
2
0
8
V
,
1
P
,
3
W
MO
U
N
T
I
N
G
:
R
E
C
E
S
S
E
D
MA
I
N
S
:
1
2
5
A
TY
P
E
:
Q
O
R
E
S
I
D
E
N
T
I
A
L
AI
C
:
1
0
K
PH
A
S
E
P
H
A
S
E
DE
S
C
R
I
P
T
I
O
N
A
B
B
K
R
P
C
I
R
C
I
R
P
B
K
R
A
B
D
E
S
C
R
I
P
T
I
O
N
DIS
H
W
A
S
H
E
R
1
0
0
0
2
0
1
1
2
1
2
0
1
0
0
0
K
I
T
,
B
A
T
H
,
C
L
O
S
E
T
L
T
S
DIS
P
O
S
A
L
1
0
0
0
2
0
1
3
4
1
2
0
9
0
0
D
I
N
I
N
G
&
L
I
V
I
N
G
T
R
A
C
K
S
MIC
R
O
W
A
V
E
8
0
0
2
0
1
5
6
1
2
0
9
0
0
L
I
V
I
N
G
R
E
C
E
P
T
A
C
L
E
S
(
5
)
RE
F
R
I
G
E
R
A
T
O
R
1
0
0
0
2
0
1
7
8
1
2
0
1
8
0
D
I
N
I
N
G
R
E
C
E
P
T
A
C
L
E
(
1
)
CO
U
N
T
E
R
R
E
C
1
5
0
0
2
0
1
9
1
0
1
2
0
9
0
0
B
E
D
R
O
O
M
R
E
C
(
5
)
CO
U
N
T
E
R
R
E
C
1
5
0
0
2
0
1
1
1
1
2
1
2
0
5
4
0
B
A
T
H
R
E
C
(
3
)
ST
O
V
E
3
0
0
0
5
0
2
1
3
1
4
1
2
0
6
2
4
H
E
A
T
M
A
T
#
1
1
2
W
/
S
F
5
0
S
F
"
3
0
0
0
1
5
1
6
0
G
F
I
AI
R
C
O
N
D
I
T
I
O
N
I
N
G
2
2
5
0
3
0
2
1
7
1
8
1
2
0
4
2
0
HE
A
T
M
A
T
#
1
&
2
1
2
W
/
S
F
3
5
S
"
2
2
5
0
1
9
2
0
0
G
F
I
WA
T
E
R
H
E
A
T
E
R
2
2
5
0
3
0
2
2
1
2
2
2
2
0
1
5
0
0
B
B
H
E
A
T
L
I
V
I
N
G
D
I
N
I
N
G
"
2
2
5
0
2
3
2
4
1
5
0
0
"
WA
T
E
R
H
E
A
T
E
R
2
2
5
0
3
0
2
2
5
2
6
2
2
0
1
2
5
0
B
B
H
E
A
T
B
E
D
R
O
O
M
"
2
2
5
0
2
7
2
8
1
2
5
0
"
SP
A
C
E
0
2
9
3
0
0
0
3
1
3
2
0
0
3
3
3
4
0
0
3
5
3
6
0
0
3
7
3
8
0
0
3
9
4
0
0
0
4
1
4
2
0
LO
A
D
C
A
L
C
U
L
A
T
I
O
N
S
U
M
M
A
R
Y
N
O
T
E
:
P
R
O
V
I
D
E
A
R
C
-
F
A
U
L
T
C
I
R
C
U
I
T
I
N
T
E
R
R
U
P
T
E
R
,
C
O
M
B
I
N
A
T
I
O
N
-
T
Y
P
E
C
I
R
C
U
I
T
B
R
E
A
K
E
R
S
F
O
R
B
R
A
N
C
H
C
I
R
C
U
I
T
S
S
U
P
P
L
Y
I
N
G
A
L
L
1
2
0
V
P
O
W
E
R
O
U
T
L
E
T
S
E
X
C
E
P
T
I
N
K
I
T
C
H
E
N
S
,
B
A
T
H
R
O
O
M
S
.
CA
L
C
U
L
A
T
E
D
P
O
W
E
R
F
A
C
T
O
R
:
E
L
E
C
T
R
I
C
H
E
A
T
E
R
S
R
E
D
U
C
E
D
T
O
4
0
%
O
F
L
O
A
D
P
E
R
N
E
C
2
2
0
.
8
2
C
0.
9
1
R
E
P
L
A
C
E
E
X
I
S
T
I
N
G
P
A
N
E
L
A
N
D
R
E
W
O
R
K
E
X
I
S
T
I
N
G
1
/
0
A
L
U
M
I
N
U
M
C
O
N
D
U
C
T
O
R
S
T
O
N
E
W
L
O
C
A
T
I
O
N
CO
N
N
E
C
T
E
D
L
O
A
D
CO
N
N
E
C
T
E
D
A
M
P
S
DE
M
A
N
D
L
O
A
D
DE
M
A
N
D
A
M
P
S
AP
P
L
I
A
N
C
E
S
0
0
0
0
LI
G
H
T
I
N
G
&
R
E
C
E
P
T
.
1
1
2
2
0
5
4
5
8
7
7
2
8
ME
C
H
A
N
I
C
A
L
2
0
0
4
4
9
6
1
7
2
4
2
.
6
8
3
KI
T
C
H
E
N
O
V
E
N
&
D
R
Y
E
R
6
0
0
0
2
9
6
0
0
0
2
9
TO
T
A
L
3
7
2
6
4
1
7
9
2
9
1
2
0
S
E
E
D
E
M
A
N
D
C
A
L
C
S
PA
N
E
L
U
N
I
T
1
0
9
QuantityVolt-AmpsDemandTotal (VA)General Dwelling unit Square footage637 General & Lighting (1st 3 KVA)637 SF X 3X100%=1911 General & Lighting (Remainder)0 SF X 3X35%=0 Kitchen Small Appliances2 EA X1500X35%=1050 Refrigerator1 EA X1000X75%=750 Dishwasher1 EA X1200X75%=900 Oven/Range (Re:table220.19)1 EA X8000X80%=6400 Disposal1 EA X1000X75%=750 Microwave1 EA X1200X75%=900 Mechanical Equipment Electric In-Floor Heat85 SF X12X40%=408 Electric Baseboard Heat22 LF X250X40%=2200 Mechanical Equipment Air Conditioning Units1 EA X4300X100%=4300 Water Heater2 EA X4500X100%=9000 Add'l 25% Largest Mech. Load1 LS X4500X25%=1125 TOTAL29694 For 208V, 1-Phase, 3 Wire Service29694(VA) /208=143AMPS Optional Calculations - 220.83(B)Volt-Amps Air Conditioning 4300100%4300 1st 8 KVA 8000100%8000 Remainder2483140%9932 TOTAL22232 For 208V, 1-Phase, 3 Wire Service22232(VA) /208=107AMPS(Per NEC Article 220 Parts I-III)Demand Load CalculationsUNIT 109
NO
T
IN
SC
O
P
E
OF
WO
R
K
04/15/2014
Antlers at Vail Unit 109 Plan Index
A-0 Cover Page
A-1 Existing and Proposed Floor Plans
EX-1 Existing Electrical Plan
E1.0 Proposed Electrical Plan