HomeMy WebLinkAboutDRB140114 Plans Approveds`
r
I
i
1
Design Review
Staff Approval
TOWN � By Joe BatcheYer at 3:20 pm, Apr 25, 2014
Second floor deck is being rebuilt due to damage from
9' -6" 9' -6" 5' 9' -6" ice failing. There is engineered drawing by KRM
Engineering. Exterior deck and finishes to be the same
,X�� - _ as the orginal deck. Exisitng deck posts and stucco
-� - -� - -- _ columns to remain unchanged
5068
LOWER LEVEL DECK EXISTING NO DAMAGE TO DECK
EXISTING
2'X 2' STUCCO PILLAR DECK
W/ 6 X 6 CEDAR POST
23' -6" x T -T' (�
In F___] APR 2 1 2014
EXISTING
2'X 2' STUCCO PILLAR
W/ 6 X 6 CEDAR POST
EXISTING
2'X 2' STUCCO PILLAR
W/ 6 X 6 CEDAR POST
24'-
2828FX
I
t 5 �
�eC� rr.�
EXISTING
TX 2' STUCCO PILLAR
'N/ 6 X 6 CEDAR POST
OF VAIL
zeze
T
NEW DECK PER ENGINEERS DRAWING
Required guards shall not have openings which
EXISTING
2'X 2' STUCCO PILLAR
Wl6X6CEDARPOST
°
❑ DECK
allow passage of a sphere 4 inches in
I
o 23'-6" x T-9"
diameter.Required guards at open -sided
❑
walking surfaces, including stairs,porches,
o
balconies or landings, shall be not less than 36
❑ i
inches (914mm) high measured vertically above
the adjacent walking surface, Grards on the
open sides of a
EXISTING
2'X 2' STUCCO PILLAR
W/ 6 X 6 CEDAR POST
-
❑ ❑❑❑❑❑ ❑ ❑❑❑ ❑ ❑❑❑ ❑ ❑ ❑❑ ❑ ❑❑ ❑ ❑❑
❑ ❑ ❑�
(-a
EXISTING
2'X2' STUCCO PILLAR
W/ 6 X 6 CEDAR POST
24'—
co
1111H,
EXISTING
2'X 7 STUCCO PILLAR
W/ 6 X 6 CEDAR POST
W
W
ce
ceit
a
Q
A0 POO�
O
M� •�
w
n
0
U
L�
m
rowN of vnr�- Ji
Design Review
Staff Approval
By Joe Batcheller at 3:20 pm, Apr 25, 2014
2
W
V
W
z
a
P
cu
8
z
P
c
158
0
z �cq
0
� U
�
t Aft. ..
- _ r
MAN
Design Review
-
~���
r �I�IIIII IIIII __ _ _
a �
_ = fr ms's" � •
}
T �s
4 r
W�Wt I tU7
D I ill 1111111111111t�
�� �rii�lll I
-,�. „! "��;,ffi,�. � _ , �:..: of �t r►� � .
4 or
ow
71%
-,� f•�II�* 1 \1111111
x
r S
-_'! a }� S�� ���s"'� [ „•
{[ mmmm�� -
to
Design Review
Staff Approval
TOWN By Joe Batcheller at 3:21 pm, Apr 25, 2014
OF
1
+�o S1
6x10 D.F. #1 OR
— — 5Yax9 G.L. (— �C.) —
J
I
I
(2) - % "0 THRU -BOLTS
BM. PER EA. COL.
PLAN
i
1Y2"
MIN. NOTCH (E) 6x6 AS
SHOWN FOR BM.
SCALE: 3/4" = 1' -0"
REMOVE OUTSIDE 1
LLEDGER PIECES S1
) -2x @ 241 O.C. +`O
�r -__- __ __- _____ - �_ ______��
SIMPSON i I
LUS26 -2, TYP.
II I�
II I
II I� ILA
==
NORTH
DECK FRAMING PLAN SCALE: 1/4" = 1' -0" �®
PLAN NOTES FOR NEW FRAMING:
1. EXISTING POSTS BELOW (ORIGINATING FROM THIS LEVEL OR ABOVE) ARE INDICATED: a
2. ALL POSTS ARE LABELED AT THE TOP.
3. EXISTING CONSTRUCTION (E) IS INDICATED THUS ( - - - - - ), NEW CONSTRUCTION (N) IS INDICATED THUS ( )
4. DECK LIVE LOAD IS 100 psf.
f
D
APR 2 1 2014
TOWN OF VAIL
� n
P 1
�
� O
d
tic
�
za
c c m
a v..
P �y(
J
�
ul
P
z
(01,
� c
la $$
Y°�
2
i a>
�
O
Zr
Q
�1
H-1
o
I a
LOH-1
designed by TDH
drawn by CI.R
checked by
Issued
PERMIT 04/01/14
sheet
S1
JOB 1403 -12