Loading...
HomeMy WebLinkAboutFP-21 1 / 2 " / 1 2 " T.O. DECKING A.F.F. 10' - 6 1/4"T.O. GWB A.F.F. 12' - 11 7/8" T.O. GWB A.F.F. 15' - 11 3/8" GARAGE 101 MUDROOM 102 LAUNDRY ROOM 103 FAMILY OFFICE 108 PANTRY 105 SECONDARY KITCHEN 104 POWDER 107 KITCHEN 106 HEARTH ROOM 109 BREAKFAST NOOK 110 ENTRY 111 ENTRY CLST. 112 DINING ROOM 113 BAR 114 LIVING ROOM 115 ELECTRICAL CLOSET 118 POWDER 116 ELEVATOR 117 B.O. GWB A.F.F. 9' - 8 1/8" B.O. DECKING A.F.F. 10' - 2 3/4" B.O. DECKING A.F.F. 9' - 11 3/4" B.O. GWB A.F.F. 8' - 6" B.O. DECKING A.F.F. 10' - 2 3/4" STOR. 117 B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 10' - 0 7/8" B.O. GWB A.F.F. 10' - 6 3/8" open to above open to above fire department connection. See FP0 for details. B.O. GWB A.F.F. 7' - 5 1/8" 2" / 12" 1 1 / 2 " / 1 2 " 1 1/2" / 1 2 " 1 1 / 2 " / 1 2 " 1 1/2" / 12" 2" / 12" 1 1/2" / 1 2 " MASTER BEDROOM 201 MASTER BATHROOM 202 W.C. 203 ERIC'S CLOSET 205 SARA'S CLOSET 206 EMMA'S ROOM 207 ERIC'S OFFICE 210 MICHAEL'S ROOM 212 MICHAEL'S BATH 213 MICHAEL'S CLST. 214 ALLIE'S ROOM 215 ALLIE'S BATH 216 ALLIE'S CLST. 217EMMA'S BATH 208 EMMA'S CLST 209 STORAGE 218 ELEVATOR 219 1 1/2" / 1 2 " B.O. GWB A.F.F. 9' - 9 5/8"B.O. GWB A.F.F. 11' - 8 1/2" 1 1/2" / 12" B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 10' - 0" B.O. DECKING A.F.F. 8' - 10 5/8" B.O. DECKING A.F.F. 7' - 3 1/4" B.O. GWB A.F.F. 8' - 6" B.O. DECKING A.F.F. 8' - 10 1/8" B.O. DECKING A.F.F. 11' - 3" 1 1/2" / 1 2 " [No Slope] B.O. GWB A.F.F. 7' - 6" B.O. GWB A.F.F. 8' - 5 1/2" B.O. GWB A.F.F. 8' - 6" 8' - 6" B.O. GWB A.F.F. 9' - 0" B.O. GWB A.F.F. 12' - 1 3/8" 2" / 12" B.O. GWB A.F.F. 9' - 0" B.O. GWB A.F.F. 10' - 3 7/8" B.O. GWB A.F.F. 13' - 1 7/8" B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 8' - 6" B.O. GWB A.F.F. 8' - 6" 8' - 0" 2" / 12" SHOWER DA Name: 1 DA Area: 390.39 113 heads for this project 41 heads for lower level 37 heads for main level 35 heads for upper level This system as shown on company print no dated for at contract no is designed to discharge at a rate of a maximum area of when supplied with water at a rate of Occupancy classification: Commodity classification: Maximum storage height: Storage arrangement: Number of heads flowing: System Type: Maximum velocity: Flow from In-Rack sprinklers: Flow from Overhead sprinklers: Flow from Inside Hoses: Flow from Outside Hoses: Other fixed flows: Total flow in system piping: Additional flow at/beyond source: Total of all flows: Calculation results for Design Area JSPIWð /PLQPð RIIORRUDUHDRYHU - Surplus Pressure at Source: Pressure Required at Source: Pressure Available at Source: at at the base of the riser. Hose stream allowance of is included in the above. 1 Allie's Rm Phoenix Automatic Resnick Res 1027 Ptarmigan Rd 0.05 IWð 56.4 gpm 78.3 psi Res 4 Wet 20.7 ft/s 0 gpm 56.4 gpm 0 gpm 0 gpm 0 gpm 56.4 gpm 0 gpm 56.4 gpm 78.3 psi 89.5 psi 11.2 psi MI L E H I G H DE S I G N G R O U P 51 5 1 B a n n o c k S t . De n v e r , C O 8 0 2 1 6 30 3 - 2 9 1 - 1 0 1 2 30 3 - 3 8 3 - 5 0 2 3 F A X fi r e s p r i n k l e r @ a f s s c o . c o m A F I R E S P R I N K L E R DE S I G N C O M P A N Y ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM - THIS SET OF FIRE SPRINKLER SHOP DRAWINGS HAVE BEEN REVIEWED AND FOUND TO BE ACCEPTABLE BY TIMOTHY N. TROSTEL, JR - N.I.C.E.T. IV # 102055. SR. ENGINEERING TECHNICIAN - FIRE PROTECTION NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINNERING TECHNOLOGIES ____________________________________/____/____ RE S N I C K R E S I D E N C E Va i l V i l l a g e S u b d i v i s i o n , F i l i n g N o . 7 , B l o c k 5 , L o t 2 10 2 7 P t a r m i g a n R o a d , V a i l , C O 8 1 6 5 7 1/8" = 1'-0" MAIN LEVEL FIRE SPRINKLER PLAN 1/8" = 1'-0" UPPER LEVEL FIRE SPRINKLER PLAN