Loading...
HomeMy WebLinkAboutB14-0095 REV1 letter APPROVED KR M CONSULTANTS, �NC. RECORD P.O.Box 4572 • Vaif,Colorado 8y 658 • 970-949-9391 TO: Steve - SRE � I II DATE.• 04/22/14 JOB NUMBER: 1404-18 i � PROJECT.• Landmark 504 Remodel I I I i ❑ RF/ ❑ MEET/NG NOTES � RESPONSE ❑ CLAR/F/CAT/ON/CHANGE I iI was informed of the desire to penetrate the concrete wall with holes for plumbing behind the kitchen on I the main level and behind the master bathroom on the upper level. I Kitchen: i �, (1) - 3" diameter hole to be added approximately 51" from party wall and 15" above the floor. Master Bath: , (1) - 5" diameter hole approximately 44" from party wall at the floor level. (2) - 1 1/2" diameter holes approximately 102" from party wall at the floor level. I've reviewed these locations, and these hoJes may be cut into the concrete wall with the following Irequirements: I The wall will most likely need to be x-rayed to avoid any reinforcement. The (2)-holes at the master bath shall be spaced at least 6" apart (center to center). I ; Please do not hesitate to call with any questions. KRM Consultants, Inc. I Structural Engineering & Design I � i P�p �j:i,;� o�p�,Q a6�o0o�S� V e�,`\\' H NNG°��� S/GNED: � �:� COPY TO: j � 3 167 : �, 0 Tim D. H nnum, PE �O•. �• !� a � � �F`�S��NAl����\��� � �tw;:,.�_�-;�;� ,�_._, I REV/EWED: I i 22 i