HomeMy WebLinkAboutB14-0098 CR2 response letter � I Y
���li � f ♦ ! .
May 12, 2014
Mr. Martin Haeberle
Town of Vail
Building Department
75 South Frontage Road West
Vail, Colorado 81657
RE: Read Residence Remodel "
B14-0098
Dear Martin,
The following responses are to the plan review comments for the Read Residence
Remodel project:
1 . Changes to gas systems, mechanical No system changes at this time.
systems? If so pxovide plans and
calculations fox the pxoposed woxk: note
these axe not defexxable.
2. Show occupancy, square footage of Occupancy Group: Residential group R-3,
addition, spxinklei alarm systems, and type Squaze footage of Addition = 372 s.£
No sprinkler system provided.
RE: A1 .0 —Pro'ect Data
3 . Refexence codes designed ro; note UBC Note now references 2012 IRC Re: A1 .0,
has not been used in ovex 10 eaxs additional notes #4
4. Show compliance with light and Light and Ventilation (Per 3031 — 2012
ventilarion requirements of section R303 IRC)
IRC 2012 edition New Bedroom/Family Level:
Required Light: 426 habitable s.f. x 8%
equals 34 s.£ Proposed: 42 s.f.
Rec�u�ired Ventilation: 426 habitable s.f. x
4% e uals 17 s.£ Pro osed: 51 s.£ '
5. Idenrify on plans showing compliance New bedroom — Type "A" window
with egxess xequixements of the section R311 Two 3 '-0"x5 '-6" operable casements
of the IRC (meets egress). Re: A3 .0 Window '
Schedule ';
6. Hand xails design and location, typical. Added information and annotation to the '
Show compliance with section R311 of the drawings. RE: 6/ASA
IRC '
7. Show compliance Eox guaxds pex secdon Added information and annotation to the
R311 IRC drawings. RE: 5/A5.0, 6/A5.0
8. Clarify walkine in compliance with secrion Walkline is in compliance. Min.
R311 IRC dimension is currently shown as 10" at
wall. We haue added the walkline to the
S e g e r b e r g , M a y h e w & A s s o c i a t e s A r c h i t e c t s , P . C . , A . I . A . �
Mail: - P.O. Boc 4700 Vail, CO 81658 e-n�ai7: info�smamhs.00m h��p://www.smazchs.com �
Mai� Offioe: F,agle-Vail 101 Eagle Road, 61dg G • Awq CO RI62� phone: 970 476 4433 • fex: 970 476 4608
Demer Offioe: 72fi00 West Colfax Ave�ue, Suitc A-140 • Lakewood, CO 80215 • phoue: 307 623 3355 • fex: 303 623 2262
� _
plan.
R�: 1/A6.0
9. Show handxaIl Note added showing existing handrail
location. RE: 1/A6.0
10. Provide electrical load calculations, To be provided by Rader Engineering
panel sizes aud locations
11. ldentify special inspections and types Re: S3.0
per Chapter 17 of the IBC 2012 edition
12. Provide design for ne�v stav showing Re: S3.0
com liancc with cutYent live and dcad loads
13. Include design foi pioposed sno�v Snow retention system to match existing
ietention system pex TOV code as amended system. Detail added to drawings. Re:
2/A4.0
These revisions have been incoiporated into the submitted plans for your review and
approval. Thanle you for taking the time today to review the new application process. It
was very helpfiil. Please let me know if you have any further comments or questions.
Sincerely,
�
Kurt Segerberg;�
Segerbeig Mayhew Architects