Loading...
HomeMy WebLinkAboutDRB140127 Plans ApprovedSHT ABBREVIATIONS SHTG & AND HDWR HARDWARE SIMILAR < ANGLE HT HEIGHT SQ AT HORIZ HORIZONTAL SQUARE FEET # POUND(S) or NUMBER HR HOUR STA AB ANCHOR BOLT HVAC HEATING, VENTILATION and STANDARD AFF ABOVE FINISHED FLOOR AIR CONDITIONING STRUCT AS! ARCHITECT'S SUPPLEMENTAL HB HOSE BIB SUSPEND(ED) INSTRUCTIONS HDAS HEADED DEFORMED ANCHOR SYS ABV ABOVE STUD SOFFIT ACOUS ACCOUSTICAL HAS HEADED ANCHOR STUD SPKL ACT ACCOUSTICAL CEILING TILE HWY HIGHWAY TOP AND BOTTOM ADD ADDENDUM HWH HOT WATER HEATER T &G ADJ ADJACENT or ADJUSTABLE HW HOT WATER TOWEL BAR AGG AGGREGATE HTR HEATER TPD AHU AIR HANDLING UNIT IBC INTERNATIONAL BUILDING TOILET PARTITION ALUM ALUMINUM CODE or INSTALLED BY TELE TELEPHONE CONTRACTOR THICK or THICKNESS ALT ALTERNATE THRESHOLD TYP TYPICAL ID INSIDE DIAMETER TEMPORARY or TEMPERATURE AVE AVENUE TEMPERED GLASS TBC TOP OF BACK OF CURB IN INCH(ES) TUBE STEEL ARCH ARCHITECTURAL TOP OF WALL TOS TOP OF STEEL INFO INFORMATION TOP OF CONCRETE ASPH ASPHALT THERMOSTAT USGS U.S. GEOLOGICAL SURVEY INSUL INSULATION or INSULATED UNDERWRITER'S LABORATORY AUTO AUTOMATIC UNLESS OTHERWISE NOTED UOS UNLESS OTHERWISE SPECIFIED INT INTERIOR UNFINISHED AD AREA DRAIN or ACCESS DOOR URINAL V VOLT INCAND INCANDESCENT VAPOR BARRIER ANOD ANODIZED VINYL COMPOSITION TILE VTR APPROX APPROXIMATE INV INVERT VINYL WALL COVERING VERT INTMED INTERMEDIATE VEST AJV AUDIO /VISUAL VINYL or SHEET VINYL AVG AVERAGE INCL INCLUDED) VIF VERIFY IN WELD JST JOIST VERIFY AWP ACOUSTICAL WALL PANEL VENTILATION VOL B.O.F. BY OWNER, FUTURE JT JOINT WOOD BD BOARD JC JANITOR CLOSET W/C WATER CLOSET KD KNOCKDOWN WORKING POINT B.O. BY OWNER WATER RESISTANT WWF BLDG BUILDING KP KICK PLATE WITH BIT BITUMINOUS KIT KITCHEN WF. WIDE FLANGE or WOOD KO KNOCKOUT FLOORING BLKG BLOCKING WINDOW WP BM BEAM or BENCH MARK LH LEFT HAND WAINSCOT WC LLH LONG LEG HORIZONTAL WT BOT BOTTOM W.O. WHERE OCCURS WGL LLV LONG LEG VERTICAL ERG BEARNING LAB LABORATORY BSMT BASEMENT B BASE LAM LAMINATE LAV LAVATORY CJ CONTROL JOINT LBL LABEL CL COLUMN LINE LKR LOCKER CONF CONFERENCE LT LIGHT C.L. CENTERLINE LTL LINTEL CIRC CIRCUMFERENCE LVR LOUVER CAB CABINET LDR LEADER C CAULKING LP LIGHTING PANEL or LIGHT CCD CONSTRUCTION CHANGE PROOF DIRECTIVE MCC, MASONRY OPENING CFL COUNTERFLASHING MAS MASONRY CG CORNER GUARD MATL MATERIAL CM CENTIMETERS MAX MAXIMUM CMU CONCRETE MASONRY UNIT MECH MECHANICAL CO CHANGE ORDER orCLEANOUT MEP MECHANICAL ELECTRICAL CT CERAMIC TILE and PLUMBING CDOT COLORADO DEPARTMENT OF MTL METAL TRANSPORTATION MFR MANUFACTURER CEM CEMENTITIOUS MIN MINIMUM CK CORK TILE MIRR MIRROR CLG CEILING MISC MISCELLANEOUS CLOS CLOSET MEMB MEMBRANE CLR CLEAR MTD MOUNT(ED) cTR COUNTER MUL MULLION COL COLUMN MED MEDIUM CONC CONCRETE MAG MAGNETIC CONSTR CONSTRUCTION CONT CONTINUOUS MACH MACHINERY MM MILLIMETERS COTRTR CONTRACTOR MH MANHOLE CORR CORRIDOR or CORRUGATED MEZZ MEZZANINE CPT CARPET MB MOISTURE BARRIER. CIP CAST IN PLACE N NORTH CONN CONNECTION (N) NEW CATV CABLE TELEVISION NIC NOT IN CONTRACT CCTV CLOSED CIRCUIT TELEVISION NTS NOT TO SCALE CU cuBlo NO NUMBER CY CUBIC YARD NOM NOMINAL DEG DEGREE NRC NOISE REDUCTION DAMP DAMPROOFING COEFFICIENT DF DRINKING FOUNTAIN OSCI OWNER SUPPLIED DEL DOUBLE CONTRACTOR INSTALLED DEPT DEPARTMENT OC ON CENTER DTL DETAIL OD OUTSIDE DIAMETER DIA DIAMETER OTO OUTSIDE -TO- OUTSIDE DIM DIMENSION OFF OFFICE DN DOWN OH OPPOSITE HAND DISP DISPENSER OPNG OPENING DR DOOR OPP OPPOSIT E DS DOWNSPOUT OF OUTSIDE FACE DWG DRAWING PC PRECAST DW R DRAWER PAC PREVIOUSLY AWARDED DIV DIVISION CONTRACT DIAG DIAGONAL P/L PROPERTY LINE DEMO DEMOLISH or DEMOLITION PLAM PLASTIC LAMINATE EJ EXPANSION JOINT PSF POUNDS PER SQUARE FOOT (E) EXISTING PSI POUNDS PER SQUARE INCH EB EXPANSION BOLT PT POST TENSIONED or E EAST PORCELAIN TILE ED EXHAUST DUCT PTDR PAPER TOWEL DISPENSER AND EF EXHAUST FAN or EACH FACE RECEPTACLE EWC ELECTRIC WATER COOLER PVC POLYVINYL CHLORIDE EA EACH PLYWD PLYWOOD EL ELEVATION PREFAB PREFABRICATED ELEC ELECTRICAL PL PLATE ELEV ELEVATOR PLAS PLASTER EMER EMERGENCY PNL PANEL ENGR ENGINEER P PAINT(ED) EOS EDGE OF SLAB PR PAIR or PROPOSAL REQUEST EQ EQUAL PROD PROJECT EQUIP EQUIPMENT PTD PAPER TOWEL DISPENSER EXf EXTERIOR PTN PARTITION ES EACH SIDE PVMT PAVEMENT EWH ELECTRIC WATER HEATER PRESTR PRESTRESSED EW EACH WAY PBO PROVIDED BY OTHERS EST ESTIMATE PAR PARALLEL FAC FIRE ALARM CABINET PREFIN PREFINISHED FA FIRE ALARM POL POLISHED FACP FIRE ALARM CONTROL PANEL PLBG PLUMBING FBO FURNISHED BY OTHER(S) PKG PARKING FD FLOOR DRAIN or FIRE DAMPER PERIM PERIMETER FE FIRE EXTINGUISHER PERF PERFORATED FEC FIRE EXTINGUISHER CABINET PTR PAPER TOWEL RECEPTACLE FFL FINISHED FLOOR LINE PRIM PRIMARY FHC FIRE HOSE CABINET PT POINT OF TANGENCY FR FIRE RESISTIVE or FIRE RATED QTY QUANTITY FDN FOUNDATION QT QUARRY TILE FIN FINISH(ED) (R) REMOVE FIXT FIXTURE R RISER FLG FLASHING RD ROOF DRAIN or ROAD FLR FLOORING) RL RAIN LEADER FLUOR FLUORESCENT RO ROUGH OPENING FRT FIRE RETARDANT TREATED ROD ROOF OVERFLOW DRAIN FRP FIBERGLASS REINFORCED RWC RAIN WATER CONDUCTOR PANELING) RAID RADIUS FT FOOT (FEET) RE REFER TO or REFERENCE FTG FOOTING REINF REINFORCED FURR FURRED or FURRING REC RECESS(ED) FUT FUTURE REF REFRIGERATOR or F FARENHEIT REFRIGERATED FVC FIRE VALVE CABINET REQD REQUIRED FHMS FLAT HEAD MACHINE SCREW RESIL RESILIENT FH FIRE HYDRANT REV REVISE, REVISED or REVISIONS) FF FINISHED FLOOR RFG ROOFING FURN FURNISH(ED) RFL REFLECTED FOM FACE OF MASONRY RM ROOM FOF FACE OF FINISH ROW RIGHT OF WAY FOS FACE OF STUD RBS RUBBER BASE STRAIGHT FOC FACE OF CONCRETE RBC RUBBER BASE COVE FHWS FLAT HEAD WOOD SCREW RB RUBBER BASE FHV FIRE HOSE VALVE RH RIGHT HAND GWB GYPSUM WALLBOARD RF RESILIENT FLOORING GC GENERAL CONTRACTOR RECPT RECEPTACLE GB GRAB BAR RBT RUBBER TILE GYP. BD. GYPSUM BOARD RVS REVERSE (SIDE) GCMU GLAZED CONCRETE MASONRY RPM REVOLUTIONS PER MINUTE UNIT(S) SPIRT SUPPORT GA GAUGE S SOUTH or SEALED GR GRADE SC SOLID CORE GL GLASS or GLAZING SCD SEAT COVER DISPENSER GND GROUND SID SOAP DISPENSER GALV GALVANIZED SNC SANITARY NAPKIN CABINET GYP GYPSUM SND SANITARY NAPKIN DISPENSER GT GLASS TILE SNR SANITARY NAPKIN RECEPTACLE GIRT GROUT SSK SERVICE SINK GI GALVANIZED IRON SS STAINLESS STEEL HC HOLLOW CORE or SR SINK RECEPTACLE HANDICAPPED SCHED SCHEDULE HM HOLLOW METAL SEC SECTION HDR HEADER SHWR SHOWER SHT SHEET SHTG SHEATHING SIM SIMILAR SPECS SPEC! FICATION(S) SQ SQUARE SF SQUARE FEET STL STEEL STA STATION STD STANDARD STOR STORAGE STRUCT STRUCTURE or STRUCTURAL SUSP SUSPEND(ED) SYM SYMMETRICAL SYS SYSTEM SOFF SOFFIT SPKR SPEAKER SPKL SPRINKLER T &B TOP AND BOTTOM T TREAD T &G TONGUE AND GROOVE TB TOWEL BAR TO TOP OF TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TV TELEVISION TELE TELEPHONE THK THICK or THICKNESS THLD THRESHOLD TYP TYPICAL TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS TBC TOP OF BACK OF CURB TS TUBE STEEL TOW TOP OF WALL TOS TOP OF STEEL TOC TOP OF CONCRETE THERM THERMOSTAT USGS U.S. GEOLOGICAL SURVEY UL UNDERWRITER'S LABORATORY LION UNLESS OTHERWISE NOTED UOS UNLESS OTHERWISE SPECIFIED UNFIN UNFINISHED UR. URINAL V VOLT VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VTR VENT THROUGH ROOF VWC VINYL WALL COVERING VERT VERTICAL VEST VESTIBULE VIN VINYL or SHEET VINYL VAR VARY or VARIES VIF VERIFY IN WELD VER VERIFY VENT VENTILATION VOL VOLUME WD WOOD W WEST or WIDE W/C WATER CLOSET WPT WORKING POINT W/R WATER RESISTANT WWF WELDED WIRE FABRIC W/ WITH W/O WITHOUT WF. WIDE FLANGE or WOOD FLOORING WDO WINDOW WP WATERPROOFING) WSCT WAINSCOT WC WALL COVERING WT WEIGHT W.O. WHERE OCCURS WGL WIRE GLASS OCCUPANCY: R1 CONSTRUCTION TYPE(S): 11A SPRINKLERED: YES i iiq iqiii i� i� iii� ALLOWABLE BUILDING HEIGHT: 4 STORIES, 65 FT BUILDING CONSTRUCTION: 11A STRUCTURAL EXTERIOR BEARING WALLS: 1 HR INTERIOR BEARING WALLS: 1 HR EXTERIOR NON - BEARING WALLS: - STRUCTURAL FRAME: 1 HR FLOORS - CEILINGS /ROOFS: 1 HR ROOFS - CEILINGS /ROOFS: 1 HR SHAFT ENCLOSURES (4+ STORIES): 1 HR STAIRWAY CONSTRUCTION: 1 HR GROSS BUILDING AREA: BUILDING HEIGHT: NUMBER OF STORIES: ESTIMATED OCCUPANT LOAD: PLUMBING FIXTURE COUNT: 241 SF /200 SF (OCC.) = 2 OCC. BUILDING CODES: 2012 INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL PUMBING CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2011 NATIONAL ELECTRICAL CODE LOCAL AMENDMENTS: EXTERIOR ELEVATION IDENTIFICATION WINDOW IDENTIFICATION 1 DRAWING NUMBER A4.01 .. SHEET NUMBER C1 WINDOW TYPE INTERIOR ELEVATION IDENTIFICATION KEYNOTE IDENTIFICATION 99 -"' DRAWING NUMBER 99 A7.01 99 NOTE NUMBER SHEET NUMBER 99 DETAIL IDENTIFICATION REVISION IDENTIFICATION 1 DRAWING NUMBER A9.01 --+ -- SHEET NUMBER 001 _ REVISION NUMBER ASI — REVISION DESCRIPTION ELEVATION DATUM IDENTIFICATION r.� LEVEL NAME WALL SECTION IDENTIFICATION _ Name Elevation 1 DRAWING NUMBER ELEVATION A5.11 r SHEET NUMBER SECTION MATERIAL GRAPHICS CONCRETE BUILDING SECTION IDENTIFICATION 1 DRAWING NUMBER 1 A5.01 — SHEET NUMBER UNDISTURBED OR COMPACTED EARTH POROUS FILL (GRAVEL) 11121IRMOMMI S 101401111011 !_ uffKaNK071 - ° AREA OF DRAWING TO r BE ENLARGED ___1 1 -'- DRAWING NUMBER A6.01 -- - - - - -- SHEET NUMBER DOOR IDENTIFICATION 308 • DOOR NUMBER ROOM /SPACE /AREA IDENTIFICATION ROOM NAME ° ROOM NAME 314 ROOM NUMBER 876.00 SF ROOM AREA STEEL ALUMINUM MASONRY - BRICK MASONRY - CONCRETE BLOCK RIDGID INSULATION } GYPSUM PLASTER PARTITION TYPE IDENTIFICATION 23A PARTITION TYPE; RE: PARTITION FINISH WOOD TYPE SCHEDULE ACOUSTICAL PARTITION TYPE IDENTIFICATION 7bH PARTITION TYPE; RE: PARTITION TYPE SCHEDULE STRUCTURAL GRID A COLUMN LETTER j-* -- COLUMN REFERENCE GUIDE COLUMN LETTER OWNER STRUCTURAL VAIL RESORTS MONROE NEWELL PO BOX 959 VAIL, CO 1400 GLENARM ST 81620 DENVER, CO 80202 GRAHAM FRANK CRAIG CARROLL P:303 51 7 -041 9 P:303 623 -4927 gfrank @vailresorts.com ccarroll @monroe- newell.com ARCHITECT MECHANICAL NEO STUDIO BA CONSULTANTS, INC 3560 WALNUT ST. UNIT A 235 FILLMORE ST DENVER, DENVER, CO 80205 CO 80207 MICHAEL NODA ALEX VALDEZ P:303 758 3800 P:303 322 1212 michael @neostudioarch.com aleX.v @ba- consultantsinc.com INTERIOR DESIGN ELECTRICAL OZ ARCHITECTURE MV CONSULTING 3003 LARIMER ST 5980 E 114TH AVE DENVER, CO 80205 THORNTON, CO 80233 KRISTIN SPIVEY MARCUS VAHLING P:303 861 -5704 P:303 325 -3271 kspivey @ozarch.com marcus @mv -c.net i 0"u"""" G E AT VA I L RENOVATIONS 174 Gore Creek Dr, Vail, CO 81657 M r Sheet # I Sheet Name GENERAL G1.01 COVER SHEET I X ARCHITECTURE A2.00 TUNNEL PLAN X A2.21 UNIT 2.1 - PLANS, RCP & INTERIOR ELEVATIONS X A10.01 INTERIOR DETAILS X T .J t • E s 1 • L PROJ. NO. 13 -10 DRAWN: KS CHECKED: MN APPROVED: MN DATE: 04.24.2014 REVISIONS ISSUED FOR: MODEL ROOM UNIT Q i � SCALE: As indicated SHEET TITLE: COVER SHEET G1 *01 x lk Mk 'I UWAAlk 21 EGRESS TRAVEL... ROUTE A I 100'- 7 3/4" ROUTE B 149'- 1 1/Z' WAS 0' 4' 8' 16' 32' 64' A NUNN M200121 rip"Aft -111- PROJ, NO. 13-10 DRAWN: KS CHECKED: MN APPROVED: MN DATE: 04.24,2014 44R 4 • lei, L • PROJ, NO. 13-10 DRAWN: KS CHECKED: MN APPROVED: MN DATE: 04.24,2014 REVISIONS ISSUED FOR: MODEL ROOM UNIT SCALE: As indicated SHEET TITLE: LEVEL 1 - LOCATION PLAN 0 ifflomill IT, 11 IN m-Am l/4r=l'-07 :5 U NIT 2.1 BATH E_ D 3/8" = 1'-0" X± DOK 2. TYP. LINO X 2 UNIT 2.1 DEMOLITION REFLECTED CEILING PLAN ) 1/4"=l'-O" ) 3/8"=I'-O" VVYC-002 0NI l� r� T"ATION �_� F_� / �� | ^�° �-| F-�� �� -��'-���1.l�������� 3/8'=l'�y ) 3/8" = V-0" Im UNIT21,11''ELEVATIONW �� � | ��/ ^ ��� ��^� ��,K ������� '� ��� 3/8 = |'ly jft UNIT 2.1 FLOOR PLAN |/4"=|-07 VWC-00| 8 UNIT 2.1 BATH N ) 3/8" = Y-0" FM 6 UNIT 2.1 REFLECTED CEILING PLAN |/4"=\-O' ===== \ | ` ' ! � | '-=------ } `___'_-, | ~� / / � !! ('_o_� UNIT 7 ELEVATION E 3/8^= l'-O' @ 12 - UNIT 2-.1-11 -[ IE VATU�ON N� � ms UNIT - GENERAL PLAN NOTES I RE: SHEET A 10.02 FOR FINISH SCHEDULE 2. ALL UNIT WALLS TO BE PAINTED P-001 U.N.0 3. ALL UNIT CEILINGS TO BE PAINTED P-003 U.N.0 4. ALL UNIT TRIM, DOOR CASING AND BASE TO BE PT-002 UN.0 5. ALL UNIT INTERIOR DOORS AND INTERIOR SIDE OF ENTRY DOORS TO eo MATCH DESIGNER'S SAMPLE f udio 6. ALL UNIT WINDOWS AND BALCONY SWINGING DOORS TO RECEIVE WINDOW TREATMENT PER SPEC. 7. ALL PAINT TRANSITIONS ARE TO OCCUR AT INSIDE CORNERS U.N.O. 8. IF EXTENT OF FINISH IS NOT SHOWN, ALL WALLS TO RECEIVE FINISH CALLED OUT 9. ANY SPECIFED FINISH CAN BE SUBSTITUTED WITH AN EQUAL ONLY BY ARCHITECTS 10. ALL WALLS TO RECEIVE BASE SHOWN ON I I /A 10.01. APPROVAL 3560 WALNUT ST. UNIT A 11, 302.2, ICC/ANSI A 117.1-2003. CARPET. CARPET OR CARPET TILE SHALL BE DENVER, C(}80205 SECURELY ATTACHED AND SHALL HAVE A FIRM CUSHION, PAD, OR PHONE 303.758.3800 BACKING OR NO CUSHION OR PAD. CARPET OR CARPET TILE SHALL HAVE A LEVEL LOOP, TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL CUT /UNCUT PILE TEXTURE. THE PILE SHALL BE V2 INCH (13 MM) MAXIMUM IN HEIGHT. EXPOSED EDGES OF CARPET SHALL BE FASTENED TO THE FLOOR AND SHALL HAVE TRIM ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH SECTION 303. 12. PAINT EXISTING WALLS, CEILINGS, TRIM, & DOORS IN THEIR ENTIRETY 11. PROVIDE NEW CARPET & PAD AT ALL UNITS AS PER INTERIOR SPECIFICATION 14. (E) BATHROOM FLOOR AND WALL TILE TO REMAIN, PROTECT DURING UNIT - DEMOLITION PLAN KEYNOTES I REMOVE STUCCO/MASONRY WALL UNDER WINDOW FOR NEW PTAC MECH. UNIT. RE: MECH. 1.1 PROVIDE OPENINGS FOR NEW VTAC UNIT, RE: MECH. 2. REMOVE BASEBOARD HEA T AND WOOD ENCLOSURE, RE: MECH. PATCH WALL AND FLOOR FOR FINISH. 3. REMOVE (E) THERMOSTAT, PATCH WALL, RE: MECH. 4, NOT USED 5. REMOVE (E) WOOD BASE IN ITS ENTIRETY. 6. REMOVE (E) HEATED TOWEL BAR, CAP ELECTRICAL CONNECTION. 7. REMOVE (E) MIRROR IN ITS ENTIRETY, REMOVE AND REINSTALL (E) 0 MAKEUP MIRROR. 8. REMOVE (B WOOD BUILT-IN UNDER COUNTER MILLWORK SHELVING UNIT -ADDALTERNATE ~ 9. REMOVE (E)TV AND BRACKET. PATCH WALL FOR NEW FINISH, 10. REMOVE (E) CEILING FAN, USE CIRCUIT FOR ADDITIONAL LIGHTS, RE: ELEC' PATCH (E)CEILING. 11, REMOVE (E) CEILING LIGHT, PREP FOR NEW FIXTURE, RE: ELEC. 12. REMOVE (E) WALL COVERING |N ITS ENTIRETY, PREP FOR NEW FINISH. > 13. REMOVE (E) WINDOW COVERING (N ITS ENTIRETY, PATCH ANY FASTENER HOLES, PREP FOR NEW FINISH. 14. REMOVE (E) RECESSED CAN, MOVE CIRCUIT T{}M|RRDRSCONCE. 0 PATCH CEILING, PREP FOR NEW FINISH. RE: ELEC. 16. REMOVE CARPET AND PAD |N ITS ENTIRETY. 16. REMOVE (E) WALL SCONCE, USE CIRCUIT FOR NEW LIGHT/HEADBOARD POWER. 17. REMOVE WALL AND DOOR |N ITS ENTIRETY, PATCH WALL AND CEILING, PREP FOR NEW FINISH. 18. REMOVE & RELOCATE (E) TELPH[>NEOUTLET 19. REMOVE & RELOCATE OUTLET ��---- 20. REMOVE & RELOCATE FIRE ALARM RENUNC|6TOR 21. REMOVE CLOSET SHELF AND ROD, PATCH WALL FOR NEW FINISH UNIT- KEYNOTES F#7 |. NEW THRU WALL PTAC UNIT (RE:MECH). PATCH (E) MASONRY WALL AROUND NEW PTAC UNIT WITH SPRAY FOAM INSULATION, SEALANT, AND STUCCO. PATCH & PREP (E) WALL FOR NEW FINISH. PROVIDE PTD WOOD ENCLOSURE RE: SHTAlO.Ol. PAINT EXPOSED MTLTDMATCH WALL COLOR. PROVIDE NEW POWER FOR PTAC, RE: ELEC. 2. NEW SURFACE MOUNTED HEADBOARD (RE: INTERIOR SPEC|RCAT|DNG). PROVIDE WOOD CLEAT AND WOOD BLOCKING FOR NEW HEADBOARD. CDNNE[J/HARO\m|RE HEADBOARD SCONCE AND � READING LIGHT INTO EXISTING SCONCE CIRCUIT. 3. NEW WOOD U#DERCOUNTER STORAGE UNIT ' ADD ALTERNATE. RE: 5&6/A 10.01 4, REFINISH/STAIN (E) DDDRJ. MATCH DESIGNER SAMPLE. S. (2) TWO 3/8'' CLEAR TEMPERED GLASS SHELVING {)NADJUSTABLE STANDARDS. |2'' DEEP: l/4` CLEAR TEMPERED GLASS COUNTERTOP PROTECTOR ON(E)COUNTER, N �.: 6. 24^ TOWEL SHELF YY/ TOWEL BAR (CENTER OVER EXISTING YYATERCLDSET). 7. 42' FLAT SCREEN TV(C)SC|) MOUNTED wV ADJUSTABLE WALL MOUNTED 4] BRACKET. PROVIDE OUTLET AND CABLE TVCONNECTION. �o � ) __ O. SKIM C{>ATOVER TEXTURED YYALL3. PAINT ��DOl. U�m�*=� ~� CO 9. 3'-6'x3''6^ WOOD FRAMED MIRROR (Q3C|). CENTER |N WALL, PROVIDE �l NEVYLi(�HTBAR ABOVE ��|kR{>R �/ ' "() 9.1 5'-7~x3''6''vYODOFRA��EDh4|RROR(OS(�|). CENTER |NVVALLPROVIDE p� `' NEW LIGHT BAR ABOVE MIRROR, ';f 9.2 3-6 ~x2'-6' WOOD FRAMED MIRROR (D3C|). CENTER |N WALL, PROVIDE r-~ 0 NEW LIGHT BAR ABOVE MIRROR. ------ - lO. NEW 6^ WOOD (VYALNUT) BASE, STAIN. ll. BUILT -IN WOOD CHARGING SHELVING UNIT. FURR OUT WALL MYl5/8^ wOL STUDS AND S/8'' GYP. BD_ TEXTURE T[) MATCH NEW WALL TEXTURES, PAINT TDMATCH. WALL COLOR, 12. WOOD DESK, PROVIDE lX4 WOOD CLEAT {JN (2) WALLS (SINGLE METAL LEG). RE: INTERIOR DESIGN SPEC. FOR MATERIAL AND PULL OUT DESK pR(�J ��[) ]]-]() UN|T.(O3(�|). PRO J, ` 13. NEW STONE THRESHOLD. FLAME FINISHED, GRANITE TDMATCH [}R/\VVkj: KS DESIGNER'S SAMPLE. 14. REFINISH EXISTING DOOR, FRAME AND HARDWARE. NEW FINISH TO CHECKED: MN MATCH DESIGNER'S SAMPLE. lS. NEW 4Z'WIDE MILLWORK WARDROBE WITH WOOD DOORS. MOVE (E) /\PpR(}\/E[}: MN SAFE INTO UNIT. 16. PROVIDE NEW TELEPHONE OUTLET, RE: |NTELEY3&ELEC. DATE: 04.24.2014 17. PROVIDE NEW DUPLEX OUTLET, RE: |NTELEVS&ELEC. 18. PROVIDE NEW DUPLEX OUTLET |NBU|[T-|N. RE: |NTELEVS&ELEC. REVISIONS 19. PROVIDE NEW VANITY SCONCE, RE: ELEC & INTERIOR SPECIFICATIONS 20. WALL PAPER ON PREPPED WALL SURFACES TDBEYVYC-OD2@GUEST ROOM.VWC'OOl 4DATHROOM 21. REPAIR WALL COVERING ATDEMOED TOWEL BAR. 22. (E) WALL SCONCES & MIRROR TO REMAIN. 23. (E) WALL COVERING/TILE T(JREMAIN. 24. PROVIDE NEW THERMOSTAT FOR PTkC' RE:kAECH B� UNIT - RCP KEYNOTES l. NEW LED REMODEL CANS, TYP.Co., ALL EXIST, CEILING LOCATIONS |N UNIT 2. NEW SURFACE MOUNTED LIGHT FIXTURE ISSUED 3. PAINT CEILING PT'003(TYP) FOR: M[>[}F[ R(}[)M []WIT 4. PAINT EXIST. CEILING BEAMS PT-002 (TYP) UNIT RCP LEGEND @ NE{} STU[l/(] 6' RECESSED REMODEL CAN LIGHT SCALE: AS indicated /-\ L_/ SURFACE MOUNTED CEILING LIGHT FIXTURE SHEET T[[[E' CE|L|N(�FAN ' [)h)IT 2.1 - PLANS, RCP & ' INTERIOR ELEVATIONS (E) WOOD CEILING BEAMS A GYP. 8O. CEILING 6" = Y-0" 1 1/2" = 1 " -0" men$ ♦ is 10 --- OOD R )OD- 13-10 DRAWN: Author (4) CRL CHROME GLASS SHELF CLAMPS, Checker APPROVED: Approver DATE: 04.17.2014 MODEL 1020 CHR I " SOLID of ) TRIM studio . . . . . . . . . . . . . . . . . 3/8" CLEAR TEMPERED 'ES - GLASS SHELVING OOD R (E) WARDROBE )OD BEYOND TO REMAIN, REFINISH/STAIN (E) DOORS TO MATCH DESIGNER'S SAMPLE 1/4" CLEAR TEMPERED GLASS COUNTERTOP PROTECTOR ON (E) COUNTER, REFINISH (E) L C. COUNTERTOP TO L— z MATCH DESIGNER'S 17 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 71h SAMPLE ZE: ).01 "A, A 1 1/2" = 1'-0" NEW 1 "X 1 1/2" WOOD EDGE TRIM, STAIN TO MATCH CABINET (E) BASE CABINET, REFINISH/STAIN (E) DOORS TO MATCH DESIGNER'S SAMPLE 1 1/2" = 1'-0" (E) WALL TO REMAIN 3/4" X V SOLID WOOD TRIM - STAIN 3/4" WOOD VENEER PLYWOOD - STAIN 5/8" GYP. BD. ON 1 5/8" METAL STUDS @ 12" O.C. LMATCH (E) WIDTH THRESHOLD DETAIL 6" = Y-0" DODDOOR - SH PER ,NER'S SAMPLE (E) STONE VANITY TO REMAIN (E) TILE COUNTERTOP EDGE TO REMAIN 3/8" VENEER PLYWOOD BACK - STAIN 3/4" VENEER PLYWOOD - STAIN 3/4!'X I" SOLID WOOD TRIM @ EDGES - STAIN 1 1/2" = 1' 0" 1 1/2" = Y-0" own (E) STONE VANITY TO REMAIN PROVIDE SOLID WOOD BLOCKING FOR NEW CABINET 3/4" VENEER PLYWOOD - STAIN 3/8" VENEER PLYWOOD BACK - STAIN 3/4" X I" SOLID WOOD TRIM @ EDGES - STAIN 7'-9" A.F.F. 9k TO REMAIN 7-2" A.F.F. 9k 7 L STUDS @ GYP. BD. ALL TO (E) WINDOW STEEL HEADER WINDOW, RE: EXTERIOR LOU PTAC UNIT, RE PTAC SLEEVE, SEALANT & BA ROD @ PTAC � PERIMETER, TY 1 1/2" = Y-0" 1 1/2" = 1'-0" (E) WINDOW I X3 WOOD TR STAIN PERFORATED I SCREEN (GRE( PATTERN) IN 1' BRONZE CHAP PTAC UNIT, RE 3X3 WOOD LE PAINT (TYP. @ CORNERS) 1p FRONT ELEVATION SIDE ELEVATION (OPP. SIM.) X2 WOOD TRIM, STAIN X4 WOOD TRIM, STAIN X2 WOOD TRIM, STAIN ERFORATED BRONZE CREEN (GRECIAN ATTERN) IN I" RONZE CHANNEL X3 WOOD LEG (TYP, i) CORNERS), STAIN X3 WOOD TRIM, STAIN BASE, STAIN LINE OF EXTERIOR WALL 3X3 WOOD LEG BELOW (TYP. @ CORNERS), STAIN RE: UNIT INT. ELEVS ELEV. VARIES I X3 WOOD TRIM - PAINT PERFORATED BRONZE SCREEN (GRECIAN PATTERN) IN I" BRONZE CHANNEL I" BRONZE "U" CHANNEL FRAME 3X3 WOOD LEG (TYP. @ CORNERS), STAIN 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 PROD. NO. 13-10 DRAWN: Author CHECKED: Checker APPROVED: Approver DATE: 04.17.2014 REVISIONS of lry studio . . . . . . . . . . . . . . . . . 3560 WALNUT ST. UNIT A DENVER, CO 80205 PHONE 303.758.3800 PROD. NO. 13-10 DRAWN: Author CHECKED: Checker APPROVED: Approver DATE: 04.17.2014 REVISIONS SCALE: As indicated 11 Olin N M111403 mr-Al I