Loading...
HomeMy WebLinkAboutB14-0180 CR1 transmittal Department of Community Development 75 South Frontage Road TQWN OF VAIL � vai�, CO 81657 Tel: 970.4792128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance of the permit. Application/Permit#(s) information applies to: � � Atten io ( ) Revisions ,�— —� � ( ) Response to Correction Letter attached copy of correction letter ( ) Deferred Submittal �Other Pr 'ec e d�ress: -�����,-I_.�- ��� ��C� °� � ) �- (Number) (Street) (Suite#) Building/Complex Name: 1 IG � Description of TransmittaU Li t of Changes, Items Attached: . . , � Applicant_Information (architect, contractor, owneNowner's rep) Contact Name: ���I`i CI�tC�� � Address City State: Zip: ContaCt Name: (use additional sheet if necessary) ' + . . . Contact Phone: � ` '� .� G C Building Permits: Revised ADDITIONAL Valuations (Labor&Materials) Contact E-Mail: G c^ ' � r ` (DO NOT include original valuation) I hereby acknow edge that I have read this application,filled out Building: $ in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to ;Plumbing: $ comply with the information and plot plan,to comply with all Town ': ordinances d state laws, and to build this structure according Electrical: $ ' to the tow 'ng and subdivision c s, design review ap- proved, I ematio I Building,and si tial Codes and other Mechanical: $ - ordinan es of the own ap ic e thereto. X �� �,� :Total: $ ner/Ow s Repr e a ' ignature(Required) Date Received: !� � � � �I � �� For Office Use Only: t�A' O� �0�� Fee Paid: J 1'1 Received From: Cash Check# TOWN OF VAIL CC: Visa/MC Last 4 CC# exp.date: Authorization # � ` RadiantWorks Professional Design Report 6/10/2014 Project Information Contact Information Project Assumptions Project Number Designed By Outdoor Temp-20°F Project Name 1�1LAGE INN PLAZA UNIT 110 8 Company Name Hiphland PlumDiny d,Fka�,� Eievation 8200 ft p0.Box 3697 Designed For , Phone Number Edgle,CO $1631-3697 W�nd Speed 8 mph Job Type Residential ,CO • - Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 2 Flow: 0.8 GPM Circuit Length: 225 ft Head: 1.7 ft Manifold Distance: 0 ft Radiant Capacity: 12141 BTU/h Heated Area: Required Heat: 7405 BTU/h Panel Load: 8021 BTU/h %Glycol: 0% Construction -ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h•ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) � : � • Floor Coverings Quantity Area R-Value Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 WaIIS Quantity Area R-Value Infiltration Total Heat Loss Wail 1 1 288 ft' R-21 0 1327 BTU/h WIItdOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 75 ft' R-2.85 0.016 2234 BTU/h DOOf's Quantity Area R-Value Infiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in' Ce11111gS Quantity Area R-Value Infiltration Total Heat Loss No Ceilings 0 0 ft' R-0 0 inZ � GC� � OMC� JUL c, � .���fi4 **Heating 1 ad lculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual*' **Snow melting cal ulations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applieations Manual** .� � Copyright(c)Watts Radiant 2008 Page 1 of 13 � � `0� �0 ��o� e ` RadiantWorks Professional Design Report 6/10/2014 Skylights Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in' GUEST BED 1 8� BATH Heat Loss Summary sz.��io ,, ,. �Oak-5!8":R-0.57 �Wall 1 0.0�o �Window 1 Q No Doors � No Ceilings p No Skylights 37.3% � : • • Floor Coverings Quantity Area R-Value Infiltration Total Heat Loss Tile-w/Mudset:R-0.15 R-0.15 W811S Quantity Area R-Value Infiltration Total Heat Loss Wall 1 1 108 ft2 R-21 0 552 BTU/h WI11dOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 18 ft2 R-2.85 0.016 551 BTU/h DOOI'S Quantity Area R-Value Infiltration Total Heat Loss Door 1 1 21 ftZ R-2.85 0.095 781 BTU/h '*Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual*` **Snow melting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual•* VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 2 of 13 � ` RadiantWorks Professional Design Report 6/10/2014 C@11111gS Quantity Area R-Value Infiltration Total Heat Loss No Ceilings 0 0 ftz R-0 0 in2 SkyllghtS Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft' R-0 0 in' HALL � CLOSET Heat Loss Summary 41.5% Tile-w/Mudset:R-0.15 �Wall 1 ::,_..,...�.. :,.. �Window 1 0.0% 0 Door 1 � No Ceilings 2g.2% p No Skylights 29.3% Zone Notes: • - Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 2 Flow: 0.71 GPM Circuit Length: 200 ft Head: 1.4 ft Manifold Distance: 0 ft Radiant Capacity: 10251 BTU/h Heated Area: Required Heat: 6542 BTU/h Panel Load: 7075 BTU/h %Glycol: 0% Construction-ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h�ft-°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) � : ` • Floor Coverings Quantity Area R-Value Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 W811S Quantity Area R-Value Infiltration Total Heat Loss Wall 1 1 405 ftz R-21 0 1859 BTU/h *'Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual*' *'Snow melting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual** VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 3 of 13 RadiantWorks Professional Design Report 6/10/2014 WIIIdOWS Quantity Area R-Value infiltration Total Heat Loss Window 1 1 85 ftZ R-2.85 0.016 2528 BTU/h DOO�S Quantity Area R-Value Infiltration Total Heat Loss No Doors 0 0 ft' R-0 0 inz C@i1117gS Quantity Area R-Value Infiltration Total Heat Loss No Ceilings 0 0 ft' R-0 0 in' Skyllghts Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 inz GUEST BED 3 8� BATH Heat Loss Summary s�.s�ro � Oak-5/8":R-0.57 _ �Wall 1 0.0°h �Window 1 0 No Doors � No Ceilings 0 No Skylights 42.4% Zone Notes: **Heating load calculations used in RadiantWorks are 6ased on the ASHRAE 2009 Fundamentals Manual'* ""Snow melting calculations used in RadiantWorks are based on the ASHRAE 200�HVAC Appiicatlons Manuaf*• VILLAGE INN PLAZA.rad Copyright(c)watts Radiant 2008 Page 4 of 13 RadiantWorks Professional Design Report 6/10/2014 • - Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 1 Flow: 0.29 GPM Circuit Length: 225 ft Head: 1 ft Manifold Distance: 0 ft Radiant Capacity: 5243 BTU/h Heated Area: Required Heat: 2585 BTU/h Panel Load: 2870 BTU/h %Glycol: 0% Construction -ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h•ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) � � • Floor Coverings Quantity Area R-Vafue Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 WaIIS Quantity Area R-Value �nfiltration Total Heat Loss Wall 1 1 108 ft2 R-21 0 624 BTU/h WIt7dOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 22 ftZ R-2.85 0.016 670 BTU/h DOOt'S Quantity Area R-Value Infiltration Total Heat Loss No Doors 0 0 ft' R-0 0 in= Ce11111gS Quantity Area R-Value Infiltration Total Heat Loss No Ceilings 0 0 ft� R-0 0 in� Skylights Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 *•Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual'* *`Snow melting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applicatlons Manual"' VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 5 of 13 RadiantWorks Professional Design Report 6/10/2014 GUEST BED 2 8� BATH Heat Loss Summary 51.7% _Oak-5!8":R-0.57 __ _._. . . . - �Wall 1 0.0% �Window 1 � No Doors � No Ceilings � No Skylights 48.3% Zone Notes: • Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 12°F #of Circuits: 6 Flow: 4.19 GPM Circuit Length: 250 ft Head: 7.2 ft Manifold Distance: 0 ft Radiant Capacity: 23583 BTU/h Heated Area: Required Heat: 23479 BTU/h Panel Load: 25125 BTU/h %Glycol: 0% Construction-ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h•ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) � � • Floor COVerlllgs Quantity Area R-Value Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 Wa11S Quantity Area R-Value Infiltration Totai Heat Loss Wall 1 1 1335 ft' R-21 0 5298 BTU/h WindOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 108 ft2 R-2.85 0.016 3204 BTU/h DOOI'S Quantity Area R-Value Infiltration Total Heat Loss Door 1 1 192 ft= R-2.85 0.095 7139 BTU/h **Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual" **Snow melting calcufations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual** VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 6 of 13 - Desi n Re ort RadiantWorks Professional 9 p 6/10/2014 CellingS Quantity Area R-Value Infiltration Total Heat Loss Ceiling 1 1 743.11 ft' R-49 0 1358 BTU/h Fireplaces Quantity Area R-Value Infiltration Total Heat Loss Fireplace 1 0 ft2 R-0 14 1921 BTU/h Skylights Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 LIVING, DINING, BAR Heat Loss Summary 37.7% 7.2% ��2 0�0 _ Oak-5/8":R-0.57 �Wall 1 �Window 1 0.0% p Door 1 �Ceiling 1 � Fireplace p No Skylights 16.9% 28.0% Zone Notes: • - Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 4 Flow: 1.25 GPM Circuit Length: 200 ft Head: 1.3 ft Manifold Distance: 0 ft Radiant Capacity: 20586 BTU/h Heated Area: Required Heat: 11503 BTU/h Panel Load: 12499 BTU/h %Glycol: 0% Construction-ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h•ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) . . � Floor Coverings Quantity Area R-Value Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 "Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual" *•Snow melting calculations used in RadiantWorks aie based on the ASHRAE 2007 HVAC Applications Manual** VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 7 of 13 RadiantWorks Professional Design Report 6/10/2014 Walls Quantity Area R-Value Infiltration Total Heat Loss Wall 1 1 558 ft' R-21 0 2599 BTU/h DOOI'S Quantity Area R-Value Infiltration Total Heat Loss Door 1 1 84 ft' R-2.85 0.095 3123 BTU/h Ce1111t9S Quantity Area R-Value Infiltration Total Heat Loss Ceiling 1 1 773.95 ft� R-49 0 1414 BTU/h WiftdOWS Quantity Area R-Value Infiltration Total Heat Loss No Windows 0 0 ft2 R-0 0 in2 SkyllghtS Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft2 R-0 0 in2 KITCHEN, FAMILY, HALL Heat Loss Summary 19.8% 43.8% _Oak-5/8":R-0.57 �Wall 1 0.0% — Door 1 � Ceiling 1 0 No Windows � No Skylights 36.4% Zone Notes: *•Heating load calculations used in RadiantWorks are 6ased on the ASHRAE 2009 Fundamentals Manuaf•' "Snow metting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual`* VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page S oi 13 RadiantWorks Professional Design Report 6/10/2014 - . Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 1 Flow: 0.35 GPM Circuit Length: 250 ft Head: 1.6 ft Manifold Distance: 0 ft Radiant Capacity: 6048 BTU/h Heated Area: Required Heat: 3238 BTUlh Panel Load: 3549 BTUlh %Glycol: 0% Construction-ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h•ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) � : � • . Fioor Coverings Quantity Area R-Value Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 W811S Quantity Area R-Value Infiltration Total Heat Loss Wall 1 1 216 ftz R-21 0 1181 BTU/h WIIIdOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 24 ft2 R-2.85 0.016 729 BTU/h DOOI'S Quantity Area R-Value Infiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 inz Ce11117gS Quantity Area R-Value �nfiltration Total Heat Loss No Ceilings 0 0 ft' R-0 0 in' Skylights Quantity Area R-Value Infiltration Total Heat�oss No Skylights 4 0 fta R-0 0 In2 '•Heating load calculations used in RadiantWorks are 6ased on the ASHRAE 2009 Fundamentals Manual" "Snow melting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual'* ViLLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 9 of 13 . _ _ _ RadiantWorks Professional Design Report 6/10/2014 BED 2 8� BATH Heat Loss Summary ss.2�io + �Oak-5/8":R-0.57 �Wall 1 0.0�o �Window 1 Q No Doors � No Ceilings � No Skylights 61.8% Zone Notes: • - Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 2 Flow: 0.66 GPM Circuit Length: 175 ft Head: 1.1 ft Manifoid Distance: 0 ft Radiant Capacity: 8523 BTU/h Heated Area: Required Heat: 6142 BTU/h Panel Load: 6621 BTU/h %Glycol: 0% Construction-ThinSlab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU/(h•ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft�°F) � • � • FIooP CoVerings Quantity Area R-Value Infiltration Totai Heat Loss Oak-5/8":R-0.57 R-0.57 W811S Quantity Area R-Value Infiltration Total Heat Loss Wall 1 1 513 ft' R-21 0 2549 BTU/h WIt1dOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 24 ft' R-2.85 0.016 729 BTU/h DOOI'S Quantity Area R-Value Infiltration Total Heat Loss Door 1 1 21 ft' R-2.85 0.095 781 BTU/h •'Heating load calcnlations used in RadiantWorks are 6ased on the ASHRAE 2009 Fundamentals Manual*` *"'Snow melting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manuai** VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 10 of 13 RadiantWorks Professional Design Report 6/10/2014 CeIlillgS Quantity Area R-Value Infiltration Total Heat Loss Ceiling 1 1 312.94 ftZ R-49 0 572 BTU/h Skylights Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ftZ R-0 0 in' BED 1, BATH, HALL Heat Loss Summary i s.s�io �s.��ro 12.3% � Oak-5/8":R-0.57 �Wall 1 -0.0% �Window 1 � Door 1 � Ceiling 1 � No Skylights 55.0% Zone Notes: • - : Design Application: Radiant Heating Supply Fluid Temp: 120°F Product: 1/2"RadiantPEX+ Delta T: 20°F #of Circuits: 2 Flow: 0.79 GPM Circuit Length: 250 ft Head: 2 ft Manifoid Distance: 0 ft Radiant Capacity: 13186 BTU/h Heated Area: Required Heat: 7248 BTU/h Panei Load: 7877 BTU/h °/a Glycol: 0% Construction-ThinSiab ThinSlab Thickness: 1.5 in Subfloor Thickness: 0.75 in ThinSlab Conductivity: 1.5 BTU!(h�ft•°F) Subfloor Conductivity: 0.085 BTU/(h•ft•°F) � � : � � : Floor Coverings Quantity Area R-Value Infiltration Total Heat Loss Oak-5/8":R-0.57 R-0.57 W811S Quantity Area R-Value Infiltration Total Heat Loss Wall 1 1 531 ft2 R-21 0 2724 BTU/h '*Heating load calculations used in RadiantWorks are 6ased on the ASHRAE 2009 Fundamentals Manual*' *`Snow melting calculations used in RadiantWorks are 6ased on the ASHRAE 2007 HVAC Applications Manual** VILLAGE INN PLAZA.rad Copyright(c)watts Radiant 2008 Page 11 of 13 RadiantWorks Professional Design Report 6/10/2014 WII7dOWS Quantity Area R-Value Infiltration Total Heat Loss Window 1 1 24 ftz R-2.85 0.016 729 BTU/h CellltlgS Quantity Area R-Value Infiltration Total Heat Loss Ceiling 1 1 483.12 ft' R-49 0 883 BTU/h DOOPS Quantity Area R-Value Infiltration Total Heat Loss No Doors 0 0 ft2 R-0 0 in' SkyllghtS Quantity Area R-Value Infiltration Total Heat Loss No Skylights 0 0 ft� R-0 0 in' MASTER BED 8� BATH Heat Loss Summary �s.a�ro 2o.a�io �Oak-5/8":R-0.57 �Wall 1 0.0% �Window 1 0 Ceiling 1 0 No Doors 0 No Skylights 62.8% *'Heating load calculations used in RadiantWorks are based on the ASHRAE 2009 Fundamentals Manual'* *'Snow melting calculations used in RadiantWorks are 6ased on the ASHRAE 2007 HVAC Applications Manual** VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 12 of 13 RadiantWorks Professional Design Report 6/10l2014 Zone Notes: Project Heat Load Summary �5�io a�io s�ro � Zone 1 �o�ro � Zone 2 Zone 3 � Zone 4 � Zone 5 31 °�° � Zone 6 � Zone 7 � Zone 8 20�ro 3�i° s�ro Project Notes: We assume the following inforrnation for this job: Ceiling R-Values-R49 Wall R-Values-R21 Window R-Values-R2.85 Door R-ValuesR2.85 Ceiling heights-9'EXCEPT FOR GREAT ROOM WHICH IS 15' Floor Coverings-PER DRAWINGS Location-VAIL Elevation-8200' "We assume that all slab areas use"The Barrier"or equivalent insulation around all perimeters. Install tubing under all tubs and showers. "We assume supply&return runs to be run in the most direct manner possible. Please verify all project information for accuracy. Signature: Date: **Heating load calculations used in RadiantWorks a►e based on the ASHRAE 2009 Fundamentals Manual*' '*Snow melting calculations used in RadiantWorks are based on the ASHRAE 2007 HVAC Applications Manual*' VILLAGE INN PLAZA.rad Copyright(c)Watts Radiant 2008 Page 13 of 13