HomeMy WebLinkAboutOTC14-0025 ' ' e� � � � _ /�. � 3 �
07-17-2015 Inspection Request Re orting _62�� Page 17
4�06 om
Requested Inspect Date: Monday July 20,2015 �
Site Address: 1281 N�RONTAGE RD W VAIL
Timber Ridge#L-18
A/P/D Information
Activity: OTC14-0025 Type: OTC Sub Type: AMF Status: ISSUED
Const Type: Occupancy: Use: Insp Area:
Owner: TOWN OF VAIL
Contractor: R&H MECHANICAL LLC Phone: 970-328-2699
Description: Replace water heater in unit L-18
Re4uested Insaection(s)
Rem: 542 PLAN-FINAL Requested Time: 08:30 AM
Requestor:
Phone:
Comments: 1- 79 Entered By: MHAEBERLE K
Assigned To: Time Ex
Action• p�
Item: 90 BLDG-Fi I Requested Time: 01:00 PM
Requestor:
Phone�
Comments: 471-5679 Entered By: MHAEBERLE K
Assigned To: M Time Exp:
Action:
�� �
�
Insaection Historv
Item: 542 PLAN-FINAL
Item: 90 BLDG-Final
REPT131 Run Id: 14641
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
TOWN OF YATL
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
OVER THE COUNTER PERMIT
OVER THE COUNTER Permit #: OTC14 -0025
Job Address: 1281 N FRONTAGE RD W VAIL
Location......: Timber Ridge #L -18
Parcel No....: 210312129001
Valuation.....: $1,000.00
OWNER TOWN OF VAIL 06/11/2014
75 S FRONTAGE RD W
VAIL
CO 81657 -5043
CONTRACTOR R & H MECHANICAL LLC
DAVID YOUNG
825 CHAMBERS AVE / PO BOX 810
EAGLE
CO 81631
License: C000003182
Description:
Replace water heater in unit L -18
Project #:
06/11/2014 Phone: 970-328-2699
#####,#,,,,,,,,,,,,,,,,, r,,,,#,,,,,,,.,.,,,,, # # #...... #,,,,, # # # „ #,.,,,,, # # ## FEE SUMM A Y
R
Building Permit ------ - - - - ->
Electrical Permit ---- - - - - ->
Mechanical Permit - - - - - ->
Plumbing Permit --- - - - - ->
$38.75 Bldg Plan Check ----- - - - - -> $25.19
$0.00 Elec Plan Check ------ - - - - -> $0.00
$20.00 Mech Plan Check ---- - - - - -> $5.00
$0.00 Plmb Plan Check ---- - - - - -> $0.00
Applied.....
Issued.. .
PRJ14 -0275
06/11/2014
06/11 /2014
Use Tax Fee--------------- - - - - -> $0.00
Additional Fees--------------- - - - - -> ($63.94)
Investigation------------------ - - - - -> $0.00
Will Call ------------------------------ > $5.00
TOTAL PERMIT FEES--------- - - - - -> $30.00
Payments ------------------------------- > $30.00
BALANCE DUE ------------------------ > $0.00
fYf,,,,, f#,. F#,# 4## rt####################J f....fYY# 14##########„# f# 1f# itV,#,##################################Mff# R# R####### x## x######################### # # ## ## ## #, # ## #, # # # # # ### # # # # ## ##
DECLARATIONS
agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit-012811
ti��lll1
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: OTC14 -0025 Address: 1281 N FRONTAGE RD W VAIL
Owner: TOWN OF VAIL Location: Timber Ridge
#L -18
Cond: 8
(PLAN): No changes to these plans may be made without the
written consent of Town of Vail staff and /or the
appropriate review committee(s).
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days
following the date of approval, pursuant to the Vail Town
Code, Chapter 12 -3 -3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become
void one (1) year following the date of final approval,
unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
combination permit-012811
TOWN OF VAIL /
Permit #: OTC14 -0025
Owner: TOWN OF VAIL
#L -18
REQUIRED INSPECTIONS AND STATUSES
Address: 1281 N FRONTAGE RD W VAIL
Location: Timber Ridge
Item: 00542 PLAN -FINAL
Item: 00090 BLDG -Final
combination permit-012811
l
TOWN OF VAIL
Community Development
Department
Community Development Department
75 South Frontage Road West
Vail, CO 81657
Tel: 970 -479 -2128
www.vailgov.com
Development Review Coordinator
WATER HEATER REPLACEMENT PERMIT APPLICATION
(Permit fee = standard building fees and design review fee)
Project Information Type of Building:
Owner Name: Timber Ridge Village Apartments
I One Family () Two Family (Duplex) (�)
Parcel #: 2103- 121 -29 -001 V
(For Parcel #, contact Eagle County Assessors Office at (970.328 -8640 or visit
www.eaglecounty.us/patie)
Project Street Address:
1281 North Frontage Road L18
(Number) (Street) (Unit #)
Contractor Information
Business Name: R & H Mechanical
Business Address: P.O. Box 810
City Eagle State: CO zip: 81631
Contact Name: Michael Keyser
Contact Phone: 970- 328 -2699
Contact E -Mail: michaelk @randhmechanical.com
Submittal Requirements:
• Joint Property Owner Written Approval Letter for new vent-
ing (duplex or multi- family HOA)
• Two (2) plan sets indicating: /
• Materials and product cut sheets V
• Type of water heater (gas or electric) ✓
• Location of water heater adjacent to existing rooms (i.e.
bedrooms, garage, etc.)
• Full view elevation photos of exterior venting location
Detailed Scope and Location of Work:
Replacement of existing water heater with like model.
(use additional sheet if necessary)
Applicant Information (fill in if different from contractor)
Applicant Name: Michael Keyser Electrical
Valuation of
Work Included Plans Included Work
( )Yes (�i )No (" )Yes (4i)NO
Applicant Phone: 970- 328 -2699 I )No 42E
)Yes (-~)No (—)Yes (
Va ue of a work being performed: $ 428
Applicant E -Mail: michaelk @randhmechanical.com (value based on IBC section 109.3 & IRC Section 1083)
�fff� ✓�T1�!t�t�t`jl'�u�+c2�16.1�nt� CCaM"'~
I hereby acknowledge that I have read this application, filled out in
full the information required, completed an accurate site plan, and
state that all the information as required is correct. I agree to
comply with the information and site plan, to comply with all Town
ordinances and state laws, and to build this structure according to
the town's zoning and subdivision codes, design review approval,
International Building and Residential Codes and other ordinances
of the Tow tt bie thereto.
Ownd'rKKvn6r's Representative Signature Required (typed or digital
signature)
( ) Checking this box indicates you are electronically signing
this application and agree to the above statement.
Electrical Square Footage
Date Received:
Received
TOWN
OF V�ti� By Carolyn Godfrey at 2:02 pm, Jun 10, 2014
For Office Use Only: , o!70
Fee Paid: Project #: ,/
Received From: Building Permit #: i , _ 1 I 0(3
Cash Check # n.
CC. Visa/MC Last 4 GC # Auth #: Lot #: __,�__ Block #� Subdivision: r� 1W )-t�
5 5 l3'I`)
13 -Jan 18
.0 '1 f7,r119 trq N1 t
YEAR -ROUND RENTAL RESIDENCES IN VAIL
CONVENIENT APARTMENT LIVING
Each spacious two- bedroom apartment
offers all the conveniences of home.
WE'VE INCLUDED:
• Dishwashers
• Garbage Disposals
Mini Blinds
• Wail to Wall Carpeting
The only thing missing is you!
I.II. d 47V?n 979 n)A << LO
IDEALLY LOCATED
Public transportation is right at the door, and
we're within walking distance of major
shopping areas. Our neighbors include Vail
Village, the Cascade Club, and LionsHead
Village - just across the street.
Vail has some of the best restaurants and
shopping for every taste.
CLOSE TO EVERYTHING... INCLUDING NATURE
Stop by for a tour, our leasing staff will be
happy to introduce you to the beauty and
convenience of Timber Ridge Village.
_rt"E*1UE-
v: ZrLX".0 E .
1280 NORTH FRONTAGE ROAD WE)T. VAIL. CO 81657
TELEPI IONE 970. 476.6759
TIMBER .RIDGE(QCORUMREALESTATE.CUM
OFFICE HOURS: MONDAY THRU FRIDAY SAM TO 517M
39aIN899WI1 19 :00 80-90 -tL
BR4DFORD WHITE
W A T E R H E A T E R S
Residential Atmospheric Vent High Performance
Energy Saver Gas Water Heater
Cq+ 4
i
The Atmospheric Vent High Performance Model features:
• High Input Combustion System— Generates enough hot water in the first
hour for hot tubs, garden tubs and body sprays in addition to whole house
duty.
• High Recovery and First Hour Delivery—When tested to the industry
standard residential first hour delivery procedure, the GX1 -55S will deliver
200 gallons.
■ Integrated Mixing Device — Features an accurate, easy to use hand wheel
for adjusting mixed water temperature, a pre -piped stainless steel flexible
connector for quick installation as well as optional water connections (1/2"
NPT recirculation inlet, 1 /2' NPT hot water outlet, 1/4" NPT cold water
outlet). This required system is easily installed and ensures a comfortable
outlet temperature while providing a steady flow of hot water.
■ Helical Fin Flue— Designed to maximize the amount of heat transferred to
water decreasing recovery time. Minimizes air movement in the heater
during standby periods to retard heat loss up the flue.
■ Factory Installed Hydrojet 2" Total Performance System —Cold water
inlet sediment reducing device helps prevent sediment build up in tank.
Increases first hour delivery of hot water while minimizing temperature build
up in tank.
■ Vitraglas" Lining— Bradford White tanks are lined with an exclusively
engineered enamel formula that provides superior tank protection from the
highly corrosive effects of hot water. This formula (Vitraglaso) is fused to the
steel surface by firing at a temperature of over 1800 °F (871'C).
■ Fully Automatic Controls— Automatic temperature selection at your
fingertips. Built -in energy cut -off switch prevents abnormally high water
temperature for extra safety. Built -in gas pressure regulation.
■ 3/4" NPT Side Connections.
■ Non -CFC Foam Insulation— Energy saving insulation covers the sides and
top of the tank, reducing the amount of heat loss while increasing jacket
rigidity. GX1 -55S has 1" of insulation.
■ Water Connections -34" NPT factory installed true dielectric fittings
extend water heater life and eases installation.
■ Two Protective Magnesium Anode Rods — Provide added protection
against corrosion for long trouble -free service.
■ 4" "Snap Lock" Draft Diverter.
■ T&P Relief Valve — Installed.
■ Brass Drain Valve — Durable tamper proof design.
A�` -ud
6 -Year Limited Tank Warranties / 6 -Year Limited Warranty on Component Parts.
(�111J1 For more information on warranty, please visit www.bradfordwhite.com
For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete
copy of the warranty included with the heater.
MANUFACTURED UNDER ONE ON MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526;
6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984;
8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS:
2,314,845: 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,885; 2,239,007; 2,092,105; 2,107,012. tiitraglae and Hydraler are registered trademarks of Gradfard While• Corperstion.
115 -B- 0214 -A
Residential Atmospheric Vent Gas Water Heater
High Performance Energy Saver Models
NATURAL GAS AND LIQUID PROPANE MODELS
Meet at exceed ASHRAE 90.1b (current standard) C.E.C. Listed
82% Thermal Etnciency
Model
Capacity
y
Recovery at
A
B
C
D
E
F
G
H
J
K
Approx.
Number
90"F Rise'
Floorto
Jacket
Vent
Floor to
Floor to
Floor to
Floor to
Floor to
floor to
Depth
Shipping
Flue
pia.
Size
T3P
Gas
Space
Space
Heater
Water
Weight
Nat. LP
Nat. Nat. LP LP
Conn
Conn.
Conn.
Heating
Heating
Top
Conn.f
U.S. Imp.
STU/Hr. BTUAtr,
U.S. Imp. U.S. Imp.
Return
Outlet
Gal. Gal.
Input Input
GPM GPH GPH GPN
in.
in.
in.
in.
In.
in.
In.
In.
in.
In.
lbs.
GX- 1.55SSBN
55 46
80,000 78,000
86 72 84 70
595/s
22
4
50
1413/is
157/is
50
56
60
26' /s
200
Model
Capacity
Recovery at
A
B
C
D
E
F
G
H
J
K
Approx.
Number
50 °C Rise'
Floor to
Jacket
Vent
Floor to
Floor to
Floor to
Floor to
Floor to
Floor to
Depth
Shipping
Flue
OW
Size
TitP
Gas
Space
Space
Heater
Water
Weight
Nat. LP
Nat. LP
Conn
Conn.
Conn.
Heating
Heating
Top
Com i
kW kW
Liters/ Liters/
Return
Outlet
Liters
Input Input
Hour Hour
mm.
mm.
mm.
mm.
mm.
mm.
mm.
mm.
mm.
mm,
kg.
GX-1-55S68N
208
23.5 22.9
326 317
1514
559
102
1270
376
392
1270
1422
1524
667
91
Propane models feature a Titanium Stainless Steel propane burner.
For propane (LP) models, change sufx'BN' to "SX ".
"Based on manufacturers rated recovery efficiency.
tDimension to top of installed mixing device.
J H
PLUG TYPE
ANODE
O
s OK
Integrated Mixinq Device ...
1 {titSliYt.�T�It{itttfi�
is r
RM \%
O
'0
.f'• =1. r1
! Fitt {S130.'�'il)1>>
L�.Il
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3/4' NPT (19mm)
on 8" (203mm) centers. All gas connections are 1/2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI standard Z- 21.10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non - potable water heating appliance.
BRADFORD WHITE'
W A T f R H E A T E R S
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford While sales representative.
Sales 800-523 -2931 • Fax 215.641 -1670 / Technical Support 800- 334 -3393 • Fax 269 -795 -1089 + Warranty B0 -531 -2111, Fax 269- 785 -1089
Intemational: Telephone 215- 641 -9400 a Telefax 215- 641 -9750 / www.bradfordwhke.com
8RADF01 0 H&M- C4NADA'1NC. Sales /Technical Support 866- 690 -0961 / 905 - 238-0100 a Fax 905-2"05/www.Wdfordwhfte,com
Built to be the BestTM
02014, Bradford White Corporation. All rights reserved.
115 -B- 0214 -A Printed in U.S.A.
X
y
Z
Model
Number
Distance
Depth of
Height
Between
Mixing
to
Centers
Device
Center
of Pipe
In,
In.
In.
GX- 1- 55S6BN
8
21/2
6
General
All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All water connections are 3/4' NPT (19mm)
on 8" (203mm) centers. All gas connections are 1/2" (13mm).
All models design certified by CSA International (formerly AGA/CGA), ANSI standard Z- 21.10.3 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water (Potable) Heating and Space Heating.
Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing
heating system or component(s) previously used with a non - potable water heating appliance.
BRADFORD WHITE'
W A T f R H E A T E R S
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford While sales representative.
Sales 800-523 -2931 • Fax 215.641 -1670 / Technical Support 800- 334 -3393 • Fax 269 -795 -1089 + Warranty B0 -531 -2111, Fax 269- 785 -1089
Intemational: Telephone 215- 641 -9400 a Telefax 215- 641 -9750 / www.bradfordwhke.com
8RADF01 0 H&M- C4NADA'1NC. Sales /Technical Support 866- 690 -0961 / 905 - 238-0100 a Fax 905-2"05/www.Wdfordwhfte,com
Built to be the BestTM
02014, Bradford White Corporation. All rights reserved.
115 -B- 0214 -A Printed in U.S.A.
Series PLT
Potable Water Expansion Tanks
Series PLT Potable Water Expansion Tanks are
designed to absorb thermal expansion and to maintain
balanced pressure throughout the potable water supply
system,
Heated water expands, and in a domestic hot water
system, the system may be closed when isolated from
the public water supply by a one -way valve, pressure
reducing valve, backflow preventer, check valve, etc.
Provisions must be made for this expansion.
Series PLT expansion tanks absorb the increased
volume of water created when the hot water storage
tank is heated and keeps the system pressure below
the relief setting of the T&P relief valve. It is a prepres-
surized steel tank with an expansion membrane that
prevents contact of the water with the air in the tank.
This prevents loss of air to the water and ensures long
and trouble -free life for the system. These tanks may
be used with all types of Direct Fired Hot Water Heaters
(gas, ail or electric) and hot water storage tanks.
• Hugged flexible butyl diaphragm
• Field adjustable pre- charge
• In -line and free standing models
• Can be used with most standard
hot water heaters and storage tanks
PLT -5 has 3/4" male connection, tank volume 2.1 gal.
PLT -12 has 3/4" male connection, tank volume 4.5 gal.
PLT -20 has 3/4" male connection, tank volume 8.5 gal.
PLT -35 has 1" female connection, tank volume 14.0 gal
♦7_ •
The potable water expansion tank shall be of drawn steel
construction and include a rigid polypropylene reservoir liner. It
shall have a butyl diaphragm separating the air chamber from
the water containing chamber. Inlet connector shall be stain-
less steel lined. Materials of manufacture for the liner and dia-
phragm shall be FDA approved. The potable water expansion
tank shall be a Watts Series PLT.
For additional information, request literature E5 -PLT.
PLT -20
..
El
PLT -12 PLT -35
PLT -5
Standards
u Pc
Models PLT -5, PLT -12 and PLT -20 are Listed
by IAPMO. Certified to ANSI /NSF 61 NSF.
Model PLT -35 Certified to ANSI/NSF 61
Selection Guide (73 °F /23 °C)
SUPPLY WATER HEATER
PRESSURE Gallons
psi bar
40 207 ___--�-
Max.
Pressure
psi bar
Max.
Temp.
'F C
Tank
Volume
gal liters
Tank
Acceptance
gat insrs
Air
Precharge
psi kPaa
Diameter
tit. mm
so 3
Weight
lbs. kgs.
PLT -5
3/4 M 20
150 10.3
200 93
2.1 8
55 3.7
20 138
8 203
11 279
5.5 2.5
PLT -12
3/4 M 20
60 4
200 93
4.5 17
2.8 10.6
20 138
10.5 267
13' /z 343
10 4.5
PLT -20
3/4 M 20
150 10.3
200 93
8.5 32
3.2 12.1
80 5.5 --_--�_
12.5 318
19.2 488
15 6.8
PLT -35
3/4 M 20
150 10.3
90 6
14.0 53
5.6 21.2
20 138
16.0 406
21.7 551
32 14.5
110 7.5
120 8.2
Q PLT -5 PLT -20
PLT -12 PLT -35
[� Multiple tanks required - consult authorized Watts agent
This table is based upon a relief valve setting of 150psi (10.3 bar),
a maximum of 40 °F (4 °C) temperature rise, and a 20psi (138 kPa)
precharge.'
"It is recommended that tanks be precharged to supply pressure
(up to 80psi (5.5 bar)). Equalizing precharge pressure to supply
pressure increases the application range over those shown in
the table.
Model
Connection
Size (DN)
in. mm
Max.
Pressure
psi bar
Max.
Temp.
'F C
Tank
Volume
gal liters
Tank
Acceptance
gat insrs
Air
Precharge
psi kPaa
Diameter
tit. mm
Length
in. mm
Weight
lbs. kgs.
PLT -5
3/4 M 20
150 10.3
200 93
2.1 8
1.26 4.8
20 138
8 203
11 279
5.5 2.5
PLT -12
3/4 M 20
150 10.3
200 93
4.5 17
2.8 10.6
20 138
10.5 267
13' /z 343
10 4.5
PLT -20
3/4 M 20
150 10.3
200 93
8.5 32
3.2 12.1
20 138
12.5 318
19.2 488
15 6.8
PLT -35
3/4 M 20
150 10.3
200 93
14.0 53
5.6 21.2
20 138
16.0 406
21.7 551
32 14.5