Loading...
HomeMy WebLinkAboutA14-0032 DATA SHEETSNetworX Control Panels Models NX-4, NX-6, NX-8 and NX-8E interlogix.com Intrusion The NetworX line of control panels represent a full-featured security system that uses advanced technology for burglary, fire and environmental detection. A highly flexible security option that is both easy to install and simple to use, NetworX control panels can accommodate smaller residential applications up to the most demanding commercial security needs. The series includes the NX-4, NX-6, NX-8 and NX-8E control panels. Outstanding features Offering up to eight standard hardwire zone inputs, the control panels also provide four programmable outputs that can be set up to activate external devices during an alarm or other system event. The modular design allows for complete integration of multiple systems within one enclosure, and adding more zones or expanding capability is fast and easy. With the addition of a Z-Wave® enabled Cellular Module, with service from Alarm.com, control of automated lights, door locks, thermostats and more is available using almost any Web enabled device. Convenient and flexible Users can conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with DL-900 software for Windows. NX-4 Four hardwire zone inputs, expandable to 8 fully programmable hardwire and/or wireless zones NX-6 Six hardwire zone inputs, expandable to 12 fully programmable hardwire or 16 wireless zones NX-8 Eight hardwire zone inputs, expandable to 48 fully programmable hardwire and/or wireless zones NX-8E Eight hardwire zone inputs and two relays, expandable to 192 fully programmable hardwire and/or wireless zones Overview • Flash memory microprocessor • Expanded event log • Early open/late close reporting • Programmable loop response • Accommodates multiple user codes from 8 up to 240 • Up to 8 true partitions with separate account codes, entry/exit delays and feature selections for each partition • Up to 512-event history log that provides date, time, event and user number • Supports SIA and contact ID communication formats • 2-wire or 4-wire smoke detector compatibility • CP-01 2000 compliant In addition, NX-8E control panel also offers • Fire alarm verification for greater false alarm immunity • Dynamic battery test • Standard RS-232 on-board interface Standard FeatureS Description NX-4 NX-6 NX-8 NX-8E Standard hardwire zones 4 6 8 8 Maximum hardwire zones 8 12 48 192 Maximum wireless zones 8 16 48 192 Partitions 1 2 8 8 Event log 185 512 User codes 8 40 99 240 Smoke loop 4-wire only 2-wire/4-wire Built-in siren driver 2 Tone (Steady & Yelp) Operating power 16.5VAC, 40VA Auxiliary power 1 Amp 2 Amp Operating temperature 0ºC to 49ºC (32ºF to 120ºF) Dimensions (H x W x D)8.3 x 9.3 x 3.5 in.11.3 x 11.3 x 3.5 in. Regulatory UL365, 609, 985, 1023, 1610, 1635, 1637 CAN/ULC-S303-M91; S545-M89; ORD-C1023-1974 Specifications NetworX Control Panels Models NX-4, NX-6, NX-8 and NX-8E North America T 855-286-8889 Asia T 852-2907-8108 Australia T 61-3-9239-1200 Europe T 32-2-725-11-20 Latin America T 561-998-6114 interlogix.com Z-Wave® is a registered US trademark of Zensys A/S. Complies with FCC and Industry Canada regulations. Specifications subject to change without notice. © 2013 Interlogix. All rights reserved. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. 302-3631 2013/06 (73841) Ordering Information NX-4 Four Hardwire Zone Inputs, Expandable to 8 Fully Programmable Hardwire and/or Wireless Zones NX-6 Six Hardwire Zone Inputs, Expandable to 12 Fully Programmable Hardwire or 16 Wireless Zones NX-8 Eight Hardwire Zone Inputs, Expandable to 48 Fully Programmable Hardwire and/or Wireless Zones NX-8E Eight Hardwire Zone Inputs and Two Relays, Expandable to 192 Fully Programmable Hardwire and/or Wireless Zones Accessories 600-1023 Transformer, 16.5VAC, 40VA NX-320E Smart Power Supply and Bus Extender NX-148E LCD Keypad NX-148E-RF LCD Keypad w/Integrated 48-Zone Wireless Receiver NX-548E 48-Zone Wireless Receiver NX-582E AES Long-Range Radio Interface Module NX-584 Home Automation Interface Module with RS-232 NX-590NE TCP/IP Module NX-591NE-GSM 3G/4G GSM Module (Multi-Carrier) NX-592E-GSM-ZX-AT Alarm.com 3G/4G GSM Module w/Z-Wave,® AT&T™ NX-592E-GSM-ZX-TM Alarm.com 3G/4G GSM Module w/Z-Wave, T-Mobile® NX-592E-CDMA-ZX-VZ Alarm.com CDMA Module w/Z-Wave, Verizon® Wireless Intrusion The NetworX wireless LCD display keypad is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to- read, customizable display. It is compatible with all NetworX control panels. The NetworX wireless LCD display keypad offers the convenience of having an integrated wireless receiver built into the keypad along with standard hardwire features. A removable door allows the user to swing the door down or simply take it off for use. The emergency keys are highlighted on the keypad and can be programmed to contact and send complete information to a responding police, fi re or EMS unit with just one touch. There are also fi ve pre-programmed touch keys that allow the most common functions to be performed with ease. All keys are backlit to ensure error-free operation — even in a dark room. The NetworX wireless LCD display keypad is cost-effective and easy to install. Designed for functionality and compatibility, it's the right keypad to fi t any application. OVERVIEW • Integrated 48-zone wireless receiver • Optimize wireless reception by having the keypad/receiver in the best location • LCD, easy-to-read programmable display • Traditional design to go with any decor • Compatible with all NetworX series control panels • Easy to install, program and maintain STANDARD FEATURES NetworX Wireless LCD Display Keypad interlogix.com North America T 855-286-8889 Latin America T 561-998-6114 Ordering Information NX-148E-RF NetworX 48-Zone LCD Display Keypad w/Door and Integrated Wireless Receiver Specifi cations Electrical Current75mA maximum Wireless Frequency319.5MHz Range600ft. (183m) open air Environmental Operating temperature32°F~120°F (0°C~49°C) Physical Dimensions (HxWxD)5.3 x 6.2 x 1.1 in. (135 x 157 x 27 mm) ConstructionABS plastic ColorWhite Specifi cations subject to change without notice. © 2014 United Technologies Corporation. All rights reserved. Interlogix is part of UTC Building & Industrial Systems, a unit of United Technologies Corporation. 305-3662 2014/03 (74998) Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring Reversible mounting bracket • • • • • Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 199-03-E 7270-1209:227 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0351-002 • 11/06 • #1676 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR 194°F/9 0 °C 5602, 5622 FX 135°F/5 7 °C 5603, 5623 FX 194°F/90 °C 5604, 5624 FX/ROR 135°F/5 7 °C 5621 Agency Listings CO1224T Carbon Monoxide Detector with RealTest™ Technology The System Sensor CO1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest• ™ technology allows installer to test detector with CO gas Full compliance with UL 2075• A code required trouble relay• Wiring supervision with SEMS terminals• A six year end-of-life timer• 12/24 VDC• A current draw of 20mA in standby and 40mA in alarm• Versatile mounting for wall and ceiling• Electrochemical sensing technology• With RealTest™ technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the CO1224T detector will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The CO1224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The CO1224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0437-000 • 8/08 • #1953 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T carbon monoxide detector with RealTest™ can evaluate the functionality of the CO sensing cell using canned test agent. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. 1.2.3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector.Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. PinPoint Addressable Point ID Systems www.GE-Interlogix.com GE Interlogix Product Information Standard Features Single two-wire loop up to two miles means fast and easy installation for new construction or retrofit applications Addressable sensors indicates exact location of alarm or trouble event Supports up to 192 devices Advanced digital communication from the sensors to the panel GE Interlogix — a name you know and trust Supports 3 Class B loops The PinPoint addressable solutions bring together NetworX NX-8E functionality with the reliability of GE Interlogix sensors. Supporting up to 192 devices on a single two-wire loop up to two miles, the PinPoint point ID solution can be installed fast in new construction or retrofit applications. Overview Components NetworX NX-8E Part # NX-8E 4 Input 4 Output Device Part # 4I4O-ID Single Input Device Part # SI-ID ShatterPro® Glassbreak Part # 5845-ID AP Series Motion Sensor Part # AP750-ID PinPoint Interface Card Part # NX-2192E PinPoint Addressable Point ID Systems Description An addressable PIR for use with the NX-2192E Pinpoint ID Bus Interface. Adaptive Single Processing – 3D signal processing with gliding focus mirror optics analyzes size, speed, shape and adaptive alarm threshold. Provides four separate curtain coverage patterns with 50' (15.2 m) range. Flat wall or corner mounting height up to 10' (3m). Ships with two plastic inserts, each covering half the coverage pattern for more flexible mounting options (center curtain always active). Specifications Housing Material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Current draw 250 µA typical avg. 3mA with LED momentarily on Transmit condition Alarm, tamper Detection range 50 ft (15.2m) Mounting height 6 to 10 ft (1.8 to 3m) Number of curtains 7 Operating temperature 32°to 131°F (0°to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 2.9' (74mm) Depth 2.2' (56mm) Height 5.1' (129mm) Listings UL 639, FCC Features AP750-ID Addressable PIR 45°Left 45°Right 50'15.2m 10'3.0m 4.8' 1.4m Coverage Patterns Description An addressable ShatterPro® II glassbreak for use with the NX-2192E PinPoint ID Bus Interface. ShatterPro's Pattern Recognition Technology™for superior detection and false alarm immunity. Protects all glass types up to a standard thickness of 1/4" (6.4 mm) including plate, wired, tempered and laminated glass. Senses through light blinds and unlined drapes. Suitable for use in occupied areas on the perimeter loop. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX 2192) Current draw 250 µA typical avg. 3mA with LED momentarily on Microphone Omni-directional electret Operating temperature 14°to 120°F (-10°to 50°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.13' (80mm) Depth 1.7' (43mm) Height 4.2' (108mm) Listings FCC Features 5845-ID Addressable Shatterpro® Glassbreak 20' (6m) max. Ceiling mount Wall mount 20' (6m)max. Description An addressable single input interface to connect a single non-addressable device to the NX-2192E PinPoint ID bus interface. Supports a single non-addressable device. Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Signaling voltage 4 to 9V Current draw 250 µA Operating temperature 32°to 131°F (0°to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.3' (84mm) Depth 1.3' (33mm) Height 2.8' (71mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features SI-ID Single Input Device Description An addressable 4 input and 4 unsupervised output interface that allows you to connect up to 4 non-addressable devices to the NX-2192E PinPoint ID Bus Interface. Supports four inputs and four unsupervised outputs (horns, bells, sirens, etc.). Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 12 to 30VDC Signaling voltage 4 to 9V Current draw 100 µA (bus loading) Output current 500mA maximum each Operating temperature 32°to 131°F (0°to 55°C) Relative Humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 6.8' (173mm) Depth 2.0' (51mm) Height 4.8' (122mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features 4I4O-ID Four Input Four Output Device From PinPoint loop To single non-addressable device, such as a magnetic contact Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop ResistanceReported to panel (47k EOL included) Addressable Inputs To unsupervised outputs, such as horns and sirens Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop ResistanceReported to panel (47k EOL included) PinPoint Addressable Point ID Systems ©2003 GE Interlogix. Smoke! in a Can is a trademark of GE Interlogix. All trademarks are properties of their owners. M-4301-XXXXKA-0103 GE Interlogix www.GE-Interlogix.com2266 Second Street North North St. Paul, MN 55109 Phone: 651-777-2690 USA & Canada: 800-777-5484 Technical Service: 800-777-2624 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 Faxback: 800-483-2495 NetworX NX-8E control panel PinPoint interface card Ge interlogix PIR Ge interlogix glassbreak Single input device 4 input 4 output device NX-8E NX-2192E AP750-ID 5845-ID SI-ID 4I4O-ID Ordering Information – – White White White White Specifications Current Draw 170 mA standby maximum Operating temperature 32°to 122°F (0°to 50°C) Shipping Weight 0.5 lb. Dimensions Width 2' (51mm) Depth 1.25' (32mm) Height 9' (229mm) Features NX-2192E Description Point ID Bus Interface Card. Attaches to the NX-8E control panel. Bus interface that supports up to 192 addressable devices on a two-mile loop. Supports three class B loops. UL UL UL FCC UL UL ModelDescription ListingApprovals PinPoint Addressable Point ID Systems Agency Listings Mini-Horns The SpectrAlert® Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features 12 and 24V operation High and low volume settings Temporal and non-temporal tones Mounts to single gang back box Compatible with MDL sync module Mechanically and electrically compatible with PA400 series Mini-Alert™ sounders • • • • • • The MHR and MHW mini-horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired. The mini-horns offer high and low volume settings, and temporal or non-temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini-horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified, unfiltered power supply. They are listed to Underwriter’s Laboratories Standard UL 464 for fire protective signaling systems. S4011 3028007 MEA7-07-E 7135-1653:196 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2007 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0414-000 • 1/07 • #1743 Ordering Information Part No.Description MHR Mini-Horn, Red MHW Mini-Horn, White SpectrAlert® Advance Mini-Horn Specifications Architectural/Engineering Specifications Mini-horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini- horn shall be listed to Underwriter’s Laboratories Standard UL464 for fire protective signaling systems. Mini-horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. When used with the Sync•Circuit™ Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Physical Specifications Dimensions 4.6˝L × 2.9˝W × .45˝D Weight 2.67 oz. Operating Temperature Range 32°F to 120°F (0°C to 49°C) Mounting Surface: single-gang back box Flush: 4˝ × 4˝ BBD deep back box (23/4˝ deep) Electrical Specifications Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8–33 Operating Voltage with MDL 9–33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8–17.5 VDC 8–17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16–33 VDC 16–33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non-temporal High 72 71 75 74 80 79 4 Non-temporal Low 70 69 73 72 78 77 Sounder Current Draw (mA RMS) Switch Position Sound Pattern Volume 8–17.5 Volts 16–33 Volts DC FWR DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non-temporal High 22 17 29 25 4 Non-temporal Low 17 13 21 19 Agency Listings Features • Electrically compatible with existing SpectrAlert products • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Plug-in design • Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 • Same mounting plate for wall- and ceiling-mount units • Shorting spring on mounting plate for continuity check before installation • Tamper resistant construction • Outdoor wall and ceiling products rated from –40°F to 151°F • Design allows minimal intrusion into the back box • Horn rated at 88+ dbA at 16 volts • Rotary switch for horn tone and three volume selections • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements • Outdoor products rainproof per UL 50 (NEMA 3R) • Compatible with MDL sync module The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field-selectable candela settings for wall and ceiling strobes and horn/strobes. When installing Advance products, first attach a universal mounting plate to a four-inch square, four-inch octagon or double-gang junction box. The two-wire mounting plate attaches to a single-gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn/strobe to the mounting plate by inserting the product’s tabs in the mounting plate’s grooves. The device will rotate into position, locking the product’s pins into the mounting plate’s terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlert® Advance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. MEA452-05-E3023572 7125-1653:186 (indoor strobes)7300-1653:187 (outdoor strobes)7125-1653:188 (horn/strobes, chime/strobes)7135-1653:189 (horns, chimes) S4011 S5512 S3593 A05-0395-003 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 × 4 × 1½-inch back box, 4-inch octagon back box or double-gang back box. Two-wire products shall also mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature –40°F to 151°F (–40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens)6.8˝ diameter × 2.5˝ high (173 mm diameter × 64 mm high) Wall mount dimensions (including lens)5.6˝L × 4.7˝W × 2.5˝D (142 mm L × 119 mm W × 64 mm D) Horn dimensions 5.6˝L × 4.7˝W × 1.3˝D (142 mm L × 119 mm W × 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2)5.9˝L × 5.0˝W × 2.2˝D (151 mm L × 128 mm W × 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, BBSCW-2)7.1˝ diameter × 2.25˝ high (180 mm diameter × 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB)5.7˝L × 5.1˝W × 2.0˝D (145 mm L × 130 mm W × 51 mm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC)7.1˝ diameter × 2.0˝ high (180 mm diameter × 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-003 Horn and Horn/Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts 24 Volt Nominal Reverberant Anechoic DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal Low 75 75 81 81 88 84 96 92 7†Coded High 82 82 88 88 93 92 101 101 8†Coded Medium 78 78 85 85 90 90 97 98 9†Coded Low 75 75 81 81 88 85 96 92 †Settings 7, 8, and 9 are not available on 2-wire horn/strobe. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC FWR DC FWR Standard Candela Range 15*123 128 66 71 15/75*142 148 77 81 30*NA NA 94 96 75*NA NA 158 153 95*NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, Standard Candela Range (15–115 cd) DC Input 8–17.5 Volts 16–33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Horn Tones and Sound Output Data UL Max. Current Draw (mA RMS), 2-wire Horn/Strobe, High Candela Range (135–185 cd) DC Input 16–33 Volts FWR Input 16–33 Volts 135 150 177 185 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Strobe Output (cd) Listed Candela Candela rating at –40°F 15 Do not use below 32°F15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0395-003 • 12/06 • #1676 SpectrAlert Advance Dimensions Model Description Wall Horn/Strobes P2R*†2-wire Horn/Strobe, Standard cd‡, Red P2RH*2-wire Horn/Strobe, High cd, Red P2RK*2-wire Horn/Strobe, Standard cd, Red, Outdoor P2RHK*2-wire Horn/Strobe, High cd, Red, Outdoor P2W*2-wire Horn/Strobe, Standard cd, White P2WH*2-wire Horn/Strobe, High cd, White P4R*4-wire Horn/Strobe, Standard cd, Red P4RH*4-wire Horn/Strobe, High cd, Red P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4W*4-wire Horn/Strobe, Standard cd, White P4WH*4-wire Horn/Strobe, High cd, White Wall Strobes SR*†Strobe, Standard cd, Red SRH*†Strobe, High cd, Red SRK Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW*Strobe, Standard cd, White SWH*Strobe, High cd, White Ceiling Horn/Strobes PC2R*2-wire Horn/Strobe, Standard cd, Red PC2RH*2-wire Horn/Strobe, High cd, Red PC2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC2RHK 2-wire Horn/Strobe, High cd, Red, Outdoor Model Description Ceiling Horn/Strobes (cont’d.) PC2W*†2-wire Horn/Strobe, Standard cd, White PC2WH*†2-wire Horn/Strobe, High cd, White PC4R 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor PC4W 4-wire Horn/Strobe, Standard cd, White PC4WH 4-wire Horn/Strobe, High cd, White Ceiling Strobes SCR*Strobe, Standard cd, Red SCRH*Strobe, High cd, Red SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCW*†Strobe, Standard cd, White SCWH*†Strobe, High cd, White Horns HR Horn, Red HRK Horn, Red, Outdoor HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White SpectrAlert Advance Ordering Information Notes: * Add “-P” to model number for plain housing (no “FIRE” marking on cover), e.g., P2R-P † Add “-SP” to model number for “FUEGO” marking on cover, e.g., P2R-SP ‡ “Standard cd,” refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. “High cd,” refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units ending in “K” include a weatherproof back box. 4.7˝ 5.6˝ 6.8˝Dia. 2.5˝ 2.5˝ 2.23˝5.05˝ 5.98˝ 7.1˝Dia. 2.25˝ 5.1˝ 2.0˝ 5.7˝ 7.1˝Dia. 2.0˝ Wall-mount horn/strobes Ceiling-mount horn/strobes Wall back box skirt Wall weatherproof back boxCeiling back box skirt Ceiling weatherproof back box