Performance: Operating Range:
Nominal Cooling Capacity(Btu/h) 36,000 Cooling(°F DB) 14-118
Cooling Power Input(kW) 2.72 Heating(°F WB) 0-64
Heating Power Input(kW) 3.58 Unit Data:
Cooling Nominal Test Conditions: Heating Nominal Test Conditions: R2f1'Ig2fdllL TYpE R410A
Indoor: 80°F DB/67°F WB Indoor: 70°F DB/60°F WB
Outdoor:95°F DB/75°F WB Outdoor:47°F DB/43°F WB Refrigerant Control EEV
Electrical: Sound Pressure3(Cool/Heat)±3 d6(A) 57/57
Power Supply(V'/Hz/�6) 208-230/60/1 Net Unit Weight(Ibs) 199
MOP(A) 25 Shipping Weight(Ibs) 217
MCA(A) 16.8 Heat Exchanger Coating GoldFin�`"
Cooling Rated Amps(A) 18.6 Min Number of Indoor Units 2
Heating Rated Amps(A) 19.0 Max Number of Indoor Units 4
Compressor(A) 12.1
Compressor:
Fan Motor(A) 1.1
MOP-MaximumOvercurrentProtection MCA-MinimumCircuitAmpacity Quantity 1
Plping: Type Twin-Rotary Inverter
Refrigerant Charge(Ibs) 7.72 Oil/Type FVC68D
Liquid Line(in,OD) 1/4(4 Each) Fan:
Vapor Line (in,OD) 3/8(4 Each)
Max Total Piping(ft)2 246.1 Type Propeller
Max ODU to IDU Piping(ft) 82� Quantity 2
Piping Length(no add'I refrigerant,ft) gg.q Fan Motor/Drive Brushless Digitally Controlled/Direct
Max Elevation between ODU and IDU(ft) 49.2 Airflow Rate(CFM) 2,119
Max Elevation between IDU and IDU(ft) 24.(, Notes:
1.Acceptable operating voltage:187V-253V.
ODU-Outdoor Unit IDU-Indoor Unit 2.Piping lengths are equivalent.
COI�trO�S FeatUre$' 3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
� 4.All power/mmmunication cable to be minimum 1S AWG,4-conductor,stranded,
•Auto operation •Low ambient operation to shielded and must complywith applicable local and national code.
S.Power wiring cable size must mmply with the applicable local and national code.
•Auto restart operation 14F(cooling mode) 6.See Engineering Manual forsensible and latentcapacities.
•Defrost/Deicing •Restartdelay(3-minutes) 7.Powerwiringcablesizemustcomplywiththeapplicablelocalandnationalcode.
S.This data is rated 0 ft above sea level,with 24.6 ft of refrigerant line and a 0 ft level
•Inverter(variable •Selfdiagnosis differencebetweenoutdoorandindoorunits.Allcapacitiesarenetwithacombination
speedcompressor) •Softstart ratiobetween95-105%.
9.Refer to the Engineering Product Data Book for combinatlon capacity tables.
lO.The outdoor unit combined with non-ducted indoor units qualifies for Energy Star.
�ptlOCld�ACCESSOCIES: 11.Must follow installation instructions in the applicable LG installation manual.
�. PI-485 Integration Board-PMNFP14A0
CJ AC Smart Premium-PQCSW421EOA
❑ AC Ez-PQCSZ250S0
❑ Power Distribution Indicator-PQNUD1500 ����S � � �
For a complete list of available accessories,contact your LG representative. Intert�k f
�� Er�EftGYST,�ft
Inverter � ��
✓
For continual product development,LG reserves the right to change specifications without notice.
LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com DFS-58-AD-004-US 014D23 Page 1 of 2
Job Name/Location:
� • Tag#:
r _
� . • ... ,� �� Date:
� �,���RS��� PO No.:
a5-��a
��r3� aa-»n 6
�a-2��3z aa-1ia
2a-15132
�
�
a �
'w ci.
n�
. . m
i�
� 5-3J16 14-9116
15-9116
1-3 !3� lfa-1111d
��QaQDQQ�Q� �
�
� aaa
�
3� � � '� �
!9
T
B71 W .J w M i
V 4� L+1 A W N � �
ttf ot � � � d �
7� � � � � � �
S Q .
m ia ,`�', � -� �3 �n
� � ip � Z3 � t�
�. m � m rb 4
� n � ro �
�
� m � 7 � � Z
7 ^ = a�
N r�P � ��,, p r6 �
C3 r [3 � rp
� � � 3
Q �
�
�
q
�
�
�
�
v
�
co
For continual product development,LG reserves the right to change specifications without notice.
LG Electronics U.S.A.,Inc.,Englewood Cliffs,NJ.All rights reserved."LG Life's Good"is a registered trademark of LG Corp./www.lghvac.com DFS-SB-AD-004-US 014D23 Page 2 of 2