Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A14-0034 Data Sheets
GE Security Overview The NetworX NX-8E is a full-featured security system that uses advanced technology for burglary, fire and environmental detection. The NX-8E is a flexible security system that is both easy to install and simple to use. With eight partitions and up to 192 zones, the NX-8E can handle your most demanding commercial and residential security needs. Outstanding features The NX-8E panel comes standard with eight hardwire zone inputs and two relays. Four programmable outputs can be set up to activate external devices during an alarm or other system event. The modular design allows for complete integration of multiple systems within one enclosure. Adding more zones or expanding capability is fast and easy. Convenient and flexible Conduct quick and easy on-site programming with alphanumeric keypads and a menu-driven text interface. Off-site programming is also available with the DL-900 software for Windows. NetworX Control Panel NX-8E Standard features • Expandable to 192 fully programmable hardwire and/or wireless zones • 240 user codes • Up to 192 addressable devices can be used • 512-event history log that provides date, time, event and user number • Up to8 true partitions with separate account codes, entry/exit delays, and feature selections for each partition • Maximum of 32 keypads with up to 8 per partition • Wireless technology with up to 192 supervised zones • 2-wire or 4-wire smoke detector compability • Fire alarm verification for greater false alarm immunity • Dynamic battery test • Standard RS-232 on-board interface GE Security © 2005 GE Security. NetworX is a trademark of GE Security All other trademarks are properties of their owners. 466-2134-KA-0105 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 www.gesecurity.com Specifications •Operating Power – 16.5V AC 40VA •Auxiliary w/40VA or 50VA transformer – 2 Amp •Auxiliary w/NX-320E power supply – 3 Amps* Loop resistance •For standard loop – 300ΩMaximum •For 2-wire smokes – 30ΩMaximum Operating temperature •32°to 120°F Dimensions •6.40 inches wide •4.0 inches high •1.10 inches deep Shipping weight •9 pounds * When using the NX-320E (w/50VA transformer) rated at 2 Amps and NX-8E (w/40VA or 50VA transformer) rated at 1 Amp, the combined available power is 3 Amps. imagination at work NetworX Control Panel NX-8E LED with Removable Door Fixed Display with Removable Door LED with Removable Door LCD with Removable Door Available Keypad Styles Customer Service and Technical Support: 1-888-GE Security (437-3287) GE Security The NX-148E-RF is an integrated 48-zone wireless receiver LCD keypad with traditional design and an easy-to-read, customizable display. It is compatible with all NetworX control panels (except commercial fire). The NX-148E-RF offers the convenience of having an integrated wireless receiver built into the keypad along with standard hardwire features. A removable door allows the user to swing the door down or simply take it off for use. The NX-148E-RF emergency keys are highlighted on the keypad and can be programmed to contact and send complete information to a responding police, fire or EMS unit with just one touch. There are also five pre-programmed touch keys that allow the most common functions to be performed with ease. All keys on the NX-148E-RF are backlit to ensure error-free operation — even in a dark room. The NX-148E-RF is cost-effective and easy to install. Designed for functionality and compatibility, the NX- 148E-RF is the right keypad to fit any application. Features • Integrated 48-zone wireless receiver • Optimize wireless reception by having the keypad/receiver in the best location • LCD, easy-to-read programmable display • Traditional design to go with any decor • Compatible with all NetworX series control panels (except commercial fire) • Easy to install, program and maintain NetworX NX-148E-RF touchpad NetworX NX-148E-RF wireless LCD display keypad Americas 503-885-5700 888-GE-SECURITY (437-3287) faxback 800-483-2495 info@gesecurity.com www.gesecurity.com Asia tel 852-2907-8108 fax 852-2142-5063 Australia tel 61-3-9259-4700 fax 61-3-9259-4799 Europe tel 32-2-725-11-20 fax 32-2-721-86-13 Latin America tel 305-593-4301 fax 305-593-4300 © 2006 GE Security. As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GE Security online at www.GESecurity.com or contact your GE Security sales representative. 20060322_DS_nx-148e-rf_466-70.B Electrical • Current: 75 to 110 mA nominal Environmental • Operating temperature: 32 to 120°F (0 to 49°C) Physical • Dimensions (HxWxD): 5.30 x 6.20 x 1.30 in. (135 x 157 x 33 mm) • Construction: ABS plastic • Color: White Specifications Ordering information NX-148E-RF NetworX 48-zone LCD display keypad with door and integrated wireless receiver P R O D U C T I N F O R M A T I O N B U L L E T I N 449/448 SERIES Self-Diagnostic, Four- Wire, Photoelectric Smoke Detectors Model numbers: 449AT, 449C, 449CT, 449CRT, 449CST, 449CSTE, 449CSRT, 449CSRH, 449CTE •Intelligent, self-diagnostics • On-site maintenance alert •Field replaceable optical chamber •Low-profile design •Plug-in terminal block •Advanced false alarm immunity The ESL 449/448 Series self-diagnostic, four-wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This unique, patented technology meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL’s proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate-of-rise and fixed 135°F (57°C), 50-foot rated, heat sensor is available with all “T” model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non-latching sounder (local alarm) for smoke, making it ideal for motel/hotel and dormitory rooms where smoking is permitted. California State Fire Marshal Approved MEA (New York City) Approved ULC model numbers: 448AT, 448C, 448CT, 448CST, 448CSRH, 448CTE continued E-3965 Rev B-1101 PH 503.692.4052 USA & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 800.483.2495 www.sentrol.com www.interlogixsecurity.com ©2001 Interlogix, Inc. Interlogix, Caddx, ESL, ITI and Sentrol are trademarks of Interlogix,Inc. Architectural and Engineering Specifications The ESL 449 Series low-profile, self-diagnostic, four-wire smoke detectors work on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photodiode as the sensing element. When the amount of light reflected onto the photodiode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient-light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the alarm relay to operate. A trouble indication is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing requirements. An internal 85 dB horn (available in “S” models) emits a temporal 3 when the detector alarms and a steady tone when power polarity is reversed. ESL 449 Series Smoke Detectors Product Data Sensitivity.................................................3.1 - 1.0%/ft. (max.) 3.1 + 0.50%/ft. (min) Operating temp. range...............32°F to 120°F (0°C to 50°C) Operating humidity range....................................0 to 95% RH Minimum voltage - C, CT, CRT, CST, CSRT, CSRH , - CSTE.........................................................................8.5V - AT..............................................................................5.1V Maximum voltage - C, CT, CRT, CST, CSRT, CSRH, - CSTE...........................................................................33V - AT................................................................................27V Maximum ripple (peak to peak)........................................10% Typical average standby current.....................................70µA - CSTE........................................................................23mA Typical alarm current - C, CT and AT............................15mA - CRT..........................................................................31mA The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. This low profile product is equipped with a hinged cover, a concealed tamper-resistant latch, and insect screens. Wiring terminates in plug-in, clamp-type screw terminals. Detectors mount to a standard single-gang electrical box, a four-inch octagonal, four-inch square electrical box, or WIREMOLD 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. - CST..........................................................................40mA - CSRT, CSRH, CSTE................................................51mA Typical avg. polarity reverse current - CST, CSRT, CSTE, and CSRH................................10mA Sounder specifications.........................................85 dB at 10' Heat detector specifications - fixed temperature..................................... 135°F (57.2°C) - rate of rise....15°F/min. & >105°F (8.3°C/min. & >40.6°C) Auxiliary relay contacts2A @ 28 VDC or 120 VAC (resistive) Alarm contacts........................ 500 mA @ 36 VDC (resistive) Field wiring size..................................................14 - 24 AWG Packaging.......................10 detectors are packed in a carton Color....................................................white cover/white base with UV inhibitor to prevent yellowing Listing.............................. UL 268, ULC FM, CSFM and MEA Selection Guide DesignatorFeatureDescription H Isolated Fixed Temp.Isolated fixed 135°F (57°C) and rate of rise heat detector, independently trips the LED and alarm and Rate of Riseoutput. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but Heat Detector does not latch. Approved as both single station smoke alarm and system heat detector. Ideal for hotel, motel and dormitory rooms where smoking is allowed. R Auxiliary RelayUsed to activate other devices such as elevator recall, door holders, strobes, etc. Listed for releasing service. S Built-in Sounder85dB built-in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated FixedIntergrated Fixed 135°F (57°C) temperature and rate of rise heat detector. Temp. and Rate ofEither heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detectorrelay outputs. E Built-in end of lineRelay is normally energized and will trip with loss of power. Can also provide notification power supervision relaywhen detector needs maintenance. Agency Listings 5600 Series Mechanical Heat Detectors System Sensor’s 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: – Single- and dual-circuit models – Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601P) Easy-to-use terminal screws A broad range of back box mounting options: – Single gang – 3.5˝ and 4˝ Octagonal – 4˝ square with square to round plaster ring Reversible mounting bracket • • • • • Multiple configurations. The 5600 series offers a full-line of configurations to accommodate a broad range of applications. Both single- and dual-circuit models are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single-gang and octagonal back boxes. And these models accommodate four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked FX/ROR. The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. S2101 3016008 199-03-E 7270-1209:227 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2006 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0351-002 • 11/06 • #1676 Specifications Architectural/Engineering Specifications Mechanical heat detector shall be a System Sensor 5600 series model number _________, listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 3½-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14–22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Specifications Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601P, 5602, 5621, and 5622 only) Mounting 3½-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6–125VAC / 3A 6–28VDC / 1A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14–22 AWG Ordering Information Model Circuit Identification Method on Exterior Temperature Rating Activation UL Protected Spacing – 10 Foot Ceiling* 5601P Single None 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5602 Single Lettering 194°F (90°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5603 Single Lettering 135°F (57°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5604 Single Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5621 Dual Lettering 135°F (57°C)Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet × 50 feet (15.24m × 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) 5624 Dual Lettering 194°F (90°C)Fixed Temperature 25 feet × 25 feet (7.62m × 7.62m) *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 5601P FX/ROR 194°F/9 0 °C 5602, 5622 FX 135°F/5 7 °C 5603, 5623 FX 194°F/90 °C 5604, 5624 FX/ROR 135°F/5 7 °C 5621 Agency Listings CO1224T Carbon Monoxide Detector with RealTest™ Technology The System Sensor CO1224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest• ™ technology allows installer to test detector with CO gas Full compliance with UL 2075• A code required trouble relay• Wiring supervision with SEMS terminals• A six year end-of-life timer• 12/24 VDC• A current draw of 20mA in standby and 40mA in alarm• Versatile mounting for wall and ceiling• Electrochemical sensing technology• With RealTest™ technology, the CO gas sensing cell of the CO1224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the CO1224T detector will alert residents by sounding and flashing a temp-4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end-of-life signal to the control panel and the central station. It also uses SEMS-type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The CO1224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The CO1224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. 2075 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 ©2008 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet.A05-0437-000 • 8/08 • #1953 Ordering Information Part No.Description CO1224T 12/24 volt, 4-wire system-monitored carbon monoxide detector with RealTest™ Technology CO1224T Carbon Monoxide Detector Specifications Architectural/Engineering Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors. The detector shall be equipped with a sounder and a trouble relay. The detector’s base shall be able to mount to a single-gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end-of-life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end-of-life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The detector shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Electrical Specifications Operating Voltage 12/24 VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A @ 30 VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32°F to 104° F (0°C to 40° C) Operating Humidity Range 22 to 90% RH Input Terminals 14 to 22 AWG Mounting Single-gang back box; surface mount to wall or ceiling Operation Modes Operation Mode Green LED Red LED Sounder Normal (standby)Blink 1 per minute —— Alarm —Blink in temp 4 pattern Sound in temp 4 pattern RealTest™ Feature: The System Sensor CO1224T carbon monoxide detector with RealTest™ can evaluate the functionality of the CO sensing cell using canned test agent. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing the Test/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector’s internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. 1.2.3. Push and hold the Test/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector.Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. PinPoint Addressable Point ID Systems www.GE-Interlogix.com GE Interlogix Product Information Standard Features Single two-wire loop up to two miles means fast and easy installation for new construction or retrofit applications Addressable sensors indicates exact location of alarm or trouble event Supports up to 192 devices Advanced digital communication from the sensors to the panel GE Interlogix — a name you know and trust Supports 3 Class B loops The PinPoint addressable solutions bring together NetworX NX-8E functionality with the reliability of GE Interlogix sensors. Supporting up to 192 devices on a single two-wire loop up to two miles, the PinPoint point ID solution can be installed fast in new construction or retrofit applications. Overview Components NetworX NX-8E Part # NX-8E 4 Input 4 Output Device Part # 4I4O-ID Single Input Device Part # SI-ID ShatterPro® Glassbreak Part # 5845-ID AP Series Motion Sensor Part # AP750-ID PinPoint Interface Card Part # NX-2192E PinPoint Addressable Point ID Systems Description An addressable PIR for use with the NX-2192E Pinpoint ID Bus Interface. Adaptive Single Processing – 3D signal processing with gliding focus mirror optics analyzes size, speed, shape and adaptive alarm threshold. Provides four separate curtain coverage patterns with 50' (15.2 m) range. Flat wall or corner mounting height up to 10' (3m). Ships with two plastic inserts, each covering half the coverage pattern for more flexible mounting options (center curtain always active). Specifications Housing Material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Current draw 250 µA typical avg. 3mA with LED momentarily on Transmit condition Alarm, tamper Detection range 50 ft (15.2m) Mounting height 6 to 10 ft (1.8 to 3m) Number of curtains 7 Operating temperature 32°to 131°F (0°to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 2.9' (74mm) Depth 2.2' (56mm) Height 5.1' (129mm) Listings UL 639, FCC Features AP750-ID Addressable PIR 45°Left 45°Right 50'15.2m 10'3.0m 4.8' 1.4m Coverage Patterns Description An addressable ShatterPro® II glassbreak for use with the NX-2192E PinPoint ID Bus Interface. ShatterPro's Pattern Recognition Technology™for superior detection and false alarm immunity. Protects all glass types up to a standard thickness of 1/4" (6.4 mm) including plate, wired, tempered and laminated glass. Senses through light blinds and unlined drapes. Suitable for use in occupied areas on the perimeter loop. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX 2192) Current draw 250 µA typical avg. 3mA with LED momentarily on Microphone Omni-directional electret Operating temperature 14°to 120°F (-10°to 50°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.13' (80mm) Depth 1.7' (43mm) Height 4.2' (108mm) Listings FCC Features 5845-ID Addressable Shatterpro® Glassbreak 20' (6m) max. Ceiling mount Wall mount 20' (6m)max. Description An addressable single input interface to connect a single non-addressable device to the NX-2192E PinPoint ID bus interface. Supports a single non-addressable device. Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 8 to 27V (as supplied by NX-2192E) Signaling voltage 4 to 9V Current draw 250 µA Operating temperature 32°to 131°F (0°to 55°C) Relative humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 3.3' (84mm) Depth 1.3' (33mm) Height 2.8' (71mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features SI-ID Single Input Device Description An addressable 4 input and 4 unsupervised output interface that allows you to connect up to 4 non-addressable devices to the NX-2192E PinPoint ID Bus Interface. Supports four inputs and four unsupervised outputs (horns, bells, sirens, etc.). Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. Specifications Housing material Flame retardant ABS Operating voltage 12 to 30VDC Signaling voltage 4 to 9V Current draw 100 µA (bus loading) Output current 500mA maximum each Operating temperature 32°to 131°F (0°to 55°C) Relative Humidity 10% to 90% noncondensing Maximum line length 10,000 ft (3km) Dimensions Width 6.8' (173mm) Depth 2.0' (51mm) Height 4.8' (122mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Features 4I4O-ID Four Input Four Output Device From PinPoint loop To single non-addressable device, such as a magnetic contact Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop ResistanceReported to panel (47k EOL included) Addressable Inputs To unsupervised outputs, such as horns and sirens Open Single EOL Double EOL Short >1MΩ 47k±5% 94k±5% >20Ω Input Loop ResistanceReported to panel (47k EOL included) PinPoint Addressable Point ID Systems ©2003 GE Interlogix. Smoke! in a Can is a trademark of GE Interlogix. All trademarks are properties of their owners. M-4301-XXXXKA-0103 GE Interlogix www.GE-Interlogix.com2266 Second Street North North St. Paul, MN 55109 Phone: 651-777-2690 USA & Canada: 800-777-5484 Technical Service: 800-777-2624 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800-547-2556 Technical Service: 800-648-7424 Faxback: 800-483-2495 NetworX NX-8E control panel PinPoint interface card Ge interlogix PIR Ge interlogix glassbreak Single input device 4 input 4 output device NX-8E NX-2192E AP750-ID 5845-ID SI-ID 4I4O-ID Ordering Information – – White White White White Specifications Current Draw 170 mA standby maximum Operating temperature 32°to 122°F (0°to 50°C) Shipping Weight 0.5 lb. Dimensions Width 2' (51mm) Depth 1.25' (32mm) Height 9' (229mm) Features NX-2192E Description Point ID Bus Interface Card. Attaches to the NX-8E control panel. Bus interface that supports up to 192 addressable devices on a two-mile loop. Supports three class B loops. UL UL UL FCC UL UL ModelDescription ListingApprovals PinPoint Addressable Point ID Systems