HomeMy WebLinkAboutB14-0243 load calcs Load Calculation Heathers Unit 3
Vail,CO
General Lighting and Receptacle Demand Load:
1300 sq.ft. x 3VA= 3900
1,500 VA x 2= 3000
1,500 VA x 1 = 1500
Total connected load: 8,400
3,000 VA @ 100%= 3,000
VA @ 35%= 1,890.0
661.5
Total general lighting and
Receptacle demand load: 3,662
Range demand load:
12,OOOVA 5,000
Dryer Load:
5,000
Fixed appliance load:
Dishwasher 1 existing 1,200
Garba e dis osal 1 existin 800
microwave 1 existing 1,200
steam shower 1 existing 8,000
subtotal 11,200
demand factor -25% 2,800
Total fixed appliance load: 8,400
Heating load:
Total heating load: �
25%of largest motor: 200
continued next a e
��
y -�y3
Load Calculation Heathers Unit 3
Vail,CO
Totals:
General lighting and receptacles: 3,662
Range: 5,000
D er: 5,000
Fixed appliance: 8,400
Heating: �
25%of largest motor: 200
Total: VA 22,262
AMPS 92.76
Existing Installed Service Size: 100A Single Phase
�4
L �
I
II�'