HomeMy WebLinkAboutB14-0243 load calcs Load Calculation Heathers Unit 3 Vail,CO General Lighting and Receptacle Demand Load: 1300 sq.ft. x 3VA= 3900 1,500 VA x 2= 3000 1,500 VA x 1 = 1500 Total connected load: 8,400 3,000 VA @ 100%= 3,000 VA @ 35%= 1,890.0 661.5 Total general lighting and Receptacle demand load: 3,662 Range demand load: 12,OOOVA 5,000 Dryer Load: 5,000 Fixed appliance load: Dishwasher 1 existing 1,200 Garba e dis osal 1 existin 800 microwave 1 existing 1,200 steam shower 1 existing 8,000 subtotal 11,200 demand factor -25% 2,800 Total fixed appliance load: 8,400 Heating load: Total heating load: � 25%of largest motor: 200 continued next a e �� y -�y3 Load Calculation Heathers Unit 3 Vail,CO Totals: General lighting and receptacles: 3,662 Range: 5,000 D er: 5,000 Fixed appliance: 8,400 Heating: � 25%of largest motor: 200 Total: VA 22,262 AMPS 92.76 Existing Installed Service Size: 100A Single Phase �4 L � I II�'