For a beautiful, open hearth gas 4��_ , � �� �m ' ' � �'�� � ��a�. ,.w.�� �
fire lace ou need a Flue SentineL � ` '��
P , Y � ���
It's an electronic damper thafi automatically opens �
when you turn on your gas logs and closes when ;� ; '��� � ���� � ,t
..� ..J`.�0 �� .�..
you turn them off. It's installed at the top of your `�°
���� �� r� ....
chimney so you never see or hear it operate but you
will immediately notice the difference. No more cold
dra{ts coming down the chimney and na more heated � The first efectronic flue damper for gas
air escaping from the chimney. The Flue Sentinel can log fireplaces
save as much as 30%on your energy bill, paying for • For hearths up to 6'wide
itself in no time.
• For flue diameters 8" to 24"
The invisible solution for • Meets new f+replace codes
� SquareJRectangular models available
the modern fireplace.
A large, open gas fireplace. • Seals chimney and eliminates cold draRs.
`� y " i • Eliminates the need for glass doors to conserve
�Heat loss. Cold, drafty rooms. Wasted energy, heat. Creates an instnnt "wow�' factor with a
��'�� - " ` large, open hearth.
A manual damper, permanent glass panes,
or glass doors. • Ultimate convenience. You never have to
��,�;,�,�,�,z f,��;��.�,p�a� remember to ciose your flue again.
� The Flue Sentinel mounts on top of the �
chimney,opens ond closes automatically, Traps heat inside the chimney.
and saves energy.
� . t''E$;11'd k"1 va 4^C{`.»"t'_� I
..__--------- —__.__..-- —�---...---�— ---�----------------- — ----.___ _.___. ...------ —
; Option Result
Direct Yent Gas Interferes with hearth and building design
Ventless Gas Limited to small fireplaces
Wood Messy,expensive,and restricted in many areas
Glass doors/Enclosures Limits view,heat,and size of hearth
Open Nearth Gas logs with Flue Sentinel Safe,quiet,natural venting that conserves energy.Natural look and feel.
��� � � �� �
' � "�r�t�x�e Y�r�� `�� x t r`�i �'��}"t������'�A'���'�t +,.a ��
; � �rH y e�q,�,�i{�r„�i� ���rq E' �... , a . ����3 t� rr s J,,.,� ,J
d ��i��G}��� `` 1 P� � � �11 ����'� � IG i
�������. ���° � t i ��
�.,��i�,^�'sa�' '� � ���'�� ���� ���'�
s�.nu�r,.... _ ���� � �P
�4C����
We offer four basic models with sizes to fit chimney
diameters from 8" to 24° with low profile options ����
thot are only six inches tall. The Flue Sentinel can
be installed in new or pre-existing chimneys. Each
unit is constructed of high grade stainless steel and , ��
comes with a two year manufacturer's warranty. �'' �' � �
�� .[
�� < ,
FSE 24 Volt Round� ������ �,, ��
For 24 VAC, 6Q Hz intermittent ignition and stpnding �.
� ��'�
pilot ignition systems for gas log fireplaces. �►
fSE 24V Rovnd r„�, e���
FSM Miliivolt Round
Designed to operate with millivolt/standing pilot '�-��,,,,�_ ��� f _
ignition systems for gas log Freplaces. "y � � �J � "'���
hs. ,� � � �����}
FSE/FSM Low Profiles •,:,��
��..
Units are 6" in height and require a vent cap. �,
� ,. ,�,� �
`. �
Recta n g u l a r/Sq u a re ,�� FSM Millivolt Round
Custom units and adapter kits can be special • �;
ordered for any chimney top. �
FSE/FSM Low Profile
Accesso ri es
Electronic Ignition Kit Combustion Air Unit
Simplifies 24 VAC installation. Electronically opens and closes as needed to
Includes: provide additional air for combustion.
• Honeywel) Intermittent Pilot Retrofit Kit • Galvanized steel construction.
• Honeywell Target Type Pilot Burner Paintable.
• Transformer. 24volt 40va Class 2 �- �r • Automatic operation. � " �'�
• l J4" pilot gas (ine - 3 feet �._ � • Two models - 4" 8 6" "+"
• 2"x 4" x 2" Electrical Junctian Box ���� _ �
• 12°x 12"x 6" Gang Box - UL Listed - t ` �
High Temp Wiring Harness Chimney Pipe Adapter Kits
Simplifies retrofit installation. Harness can be We provide adapter kits to connect the
installed in the flue for direct connection to Flue Sentine) to air cooled chimney �
the gas valve. pipe. Our kits connect all major
� '
• UL rated for continuous temps brands of pipe with O.D.s ranging }� ` m
�
to 1000° F from 8" up to 16".
• Works with 24 volt and millivolt systems
• Available in lengths 25'-60'
FSE Series
FSE Series Yolta Fre uen Current Mtiximum Current 0 rutin Tem rdture Timin
24 VAC 50/60 Hz 80 mA 5 A Controiier: -40°-140°F 7 seconds to open
A Pipe: -40°-650°F 30-40 seconds to close
0 1 Model A B C D Wei ht Ibs.
� B FSE-8 7.$ 10.5 17.Q 13.$ 7.$
� FSE-10 9.8 10.5 19.0 15.8 8.9
FSE-1 i 10.8 10.5 2fl.0 1 b.8 9.4
FSE-12 11.8 10.5 21.0 17.8 10.0
ee ^ �` D FSE-13 12.8 12.5 22.0 18.8 11.3
o FSE-14 13.8 12.5 23.0 14.8 12.0
C ° FSE-16 15.8 12.5 25.0 21.8 13.3
° FSE-18 17.8 13.5 27A 23.8 15.6
° �� ° �� FSE-20 19.8 14.5 29.0 25.8 17.8
FSE-22 21.8 15.5 31.4 27.8 20.1
FSE-24 23.8 16.5 33.0 29.8 22.9
FSM Series
FSM Series Controller Volta e Switchin Volta e Batte life 0 rutin Tem rature Timin
^--A 3.6 VDC lOQ-750 mVDC 10 years ControAer: -4Q°-14Q°F 7 seconds to open
1 Pipe: -40°-650°F 30-40 seconds to close
B Model A B t D Wei ht Ibs.
'� FSM-8 7.9 10.5 17.8 13.$ 7.8
1 FSM-10 9.9 10.5 19.8 15.8 8.9
C � FSM-11 10.9 10.5 20.8 16.8 9.4
FSM-12 11.9 1 Q.5 21.8 17.8 10.0
FSM-13 12.9 12.5 22.8 18.8 11.3
FSM-14 13.9 12.5 23.8 19.8 12.0
FSM-ib 15.9 12.5 25.8 2i.8 13.3
FSM-18 17.9 13.5 27.$ 23.8 15.6
FSM-20 19.9 14.5 29.8 25.8 17.8
� FSM-22 21.9 15.5 31.8 27.8 20.1
FSM-24 23.9 16.5 33.8 29.8 22.9
FSE Low Profile&FSM Low Profile-Vent Cap Required
�ow Profile Model A B C D Wei ht (bs. Clearance in.
q FSE-L61 FSM-Lb 5.9 6.0 14.5 11.8 4.Q2 .25
1 FSE-L8/FSM-L8 7.9 6.Q 16.5 13.8 4.25 1.25
B FSE-L]0/FSM-L10 9.9 6.0 18.5 15.8 525 2.25
, FSE-Ll t/FSM-L11 10.9 6.0 19.5 1 b.8 5.81 2.75
p FSE-l12/FSM-L12 11.9 6.0 21.5 17.8 6.3b 3.25
���� FSE-L13/FSM-Ll 3 12.9 6.0 22.5 1$.8 6.55 3.75
•� FSE-L141 FSM-L14 13.9 6.0 23.5 19.8 7.07 4.25
FSE-ll b/FSM-L16 15.9 6.0 25.5 21.8 8.25 5.25
FSE-L18/FSM-Ll 8 17.9 6.0 27.5 23.8 9.8Q 6.25
FSE-L20f FSM-L20 19.9 6.0 29.5 25.8 11.25 7.25
FSE-L22/FSM-L22 21.9 6.0 31.5 27.$ 12.35 8.25
---C-- FSE-L24/FSM-L24 23.9 6.0 33.5 29.8 13.75 9.25
EIELpCONTROLS
fieldcontrols.com
Field Controls,LtC 2630 Airport Road Kinston, NC 28504 t:252.522.3031 f:252.522.0214
m2013 Field Controls Form#4356 Printed in U.SA.(RS13)
HARGROVE GAS L(�GS �
ROBERT SHAW 7000MV (RME-PO-HB) _,
MILLIVOLT GAS VALVE SYSTEM Hargrcave
HEARTH PRO�UCTS
INSTALLATION INSTRUCTIONS
r+47ioNw� ,,y„,�cort^+c�;d ihal our gas
FIREOLAC!
� INiT1TIlTE ��-,��!Fi pfO�UCtS bQ�fI5�2�iGd
t�cd sernced 6y profes-
! -,�-ona4s who are certrt�e0 in
E � !te U S.Oy!he NaUOna1
F��r oF leca InsOtUte"�NPi)as
i CERTIFlEO riF i Gas Spec�i�sls.
�...._,....,..�-_.
This gas pilot safety valve provides 100°Io shut-off of FOR YOUR SAFETY
both pilot and main burner gas supply in the event of
pilot flame failure. This valve is equipped with a
manual gas control knob to provide for pilot lighting. IF YOU SMELL GAS:
It also has a control knob that controls flame height.
1. OPEN WINDOWS
If the pilot flame goes out during normal operation, or
if there is insufficient pilot flame to provide proper 2•DON'T TOUCH ELECTRICAL
thermocouple output, the safety valve will close, SWITCHES
stopping the flow of all gas. This valve is designed for
use on all domestic heating gases up to 1/2" PSI. 3. EXTINGIJISH ALL OPEN FLAMES
4. IMMEDIATELY CALL YOUR GAS
SUPPLIER
CAUTIONS
1. This valve should be installed only by an FLAMMABLE VAPORS MAY BE
experienced service technician trained in gas DRAWN BY AIR CURRENTS FROM
safety equipment. OTHER AREAS OF YOUR HOUSE
2. Turn off gas supply before installing valve. TO THIS APPLIANCE.
3. All piping must meet applicable local codes
and ordinances and the national fuel gas code
(ANSI Z223.1/NFPA NO.54)
4. All wiring must meet applicable electrical FOR YOUR SAFETY
codes and ordinances.
5. Check out the complete system after DO NOT STORE OR USE
installing the valve. GASOLINE OR
6. Prior to installation, verify conformance OTHER FLAMMABLE VAPORS
with burner manufacturer's installation AND LIQUIDS IN THE VICIIVITY OF
instructions. THIS OR ANY OTHER APPLIANCE.
7.Make sure a11 piping is free of foreign matter.
IN5TALLATION INSTRUCTIONS
! WARNING !
Fire hazard. Do not disassemble or attempt repair of this unit. Disassembly, reassembly or internal
adjustment could cause valve to malfunction,resulting in personai injnry,death or property damage.
If the control valve does not operate properly following installatian or service, replace the unit.
DO NOT INSTALL THE RSMVNG-C BEHIND THE
H-BURNER PAN IN THE FIREPLACE. RSMVNG-C
WARNING: Valves may not shut off if flow is not MAY OVERHEAT.
in direction of arrow on valve body.
}'4 �
WARNING:Warranty is void if RSMVNG-C is '��.,;
installed behind the H-Burner. �\��
, �„.
(Fig.1)
----- ----�1-------
,� , - ,
l'�� _�
�`� i
Parts List(Fig.2): - '�
1. (RSMVNG-C(Robertshaw Millivolt Safety Gas Valve , �
2. (RS-HS-225)Millivolt Valve Heat Shield w/Fiberglass Mat �
3.(RSTPG-48)Thermopile&Pilot Burner Assembly
4.Wall Switch and Cover Plate H-BURNER PAN RSMVNG-C
5.20' of 18 Gauge Wire Remote Control(o hn 'onal)-ordered separately
6. (2)#8 x 1/:"Screws
7. (49-6-8)1/z"X 3/8" Brass Elbow A. RC Al2V-J- 12-Volt battery operated remote and receiver
8. (69-6-8) 1/2 Mx3/8FL TANK FTTTING) B. RC 110-V-requires 110-Volt electricity for the receiver
Note: Pinin¢from gas sunnlv to valve and from valve to burner
must be supplied by installer when installed outside the firebox.
Note: Pipin fg rom ag s su�,plv to valve and from valve
to burner must be su�lied bv installer when installed
outside the firebox.
Fi9.2 Parts Included In RME-PO Kit
� , .
� • ��
1 3 �_ ,...
, .
_ y _
5. ,,..�- �,,�
• '�—___.�:/�',—
,
�. _ � ;
� �� �i ,f � �� �*a�. ^-���•
��t { 1 . �f° �� �. '� �,.`\' �.,-�
.t�� � .
'�.� �,%�,'� 1 f, �, 6• t�- � �``--
� r
��' ;"�
4.
2. g, y
a
�,�. 7• q <t
,, . �
INSTALLATION INSTRUCTIONS
Thermopile and Pilot Burner Assembly
1. Attach the pilot generatar (thermopile and pilot burner assembly) to the pilot bracket using the (2) #10-32 x 1/4"
screws. (Fig.3)
2. Connect the pilot bracket to the back side of the burner pan using the (2)#SXl/2 screws. (Fig.3)
3. Connect opposite end of the pilot tubing to the pilot port on the gas valve. (Fig.3)
4. Attach the leads from the thermopile (pilot generator)to the ternunals labeled "TP" on the valve. (Fig.4)
* Make sure the pilot tubing and thermopile leads do not contact any parts that get hot or run through any
areas that may have flames.
FIg.3 TOP VIEW OF
BURNER INSTALLATION �, `=
� �� H-BURNER
� �
49-6- , q ��"�.
,�-
� � '� \
� �`° � �
�^. s�
RSMVNG-C "����' =;� �'�� , .-�"�STPG-48
*
69-6-8 ASSEMBLY ��-'
� �_._
��`�,'.
49-6-6Z �
(INCLUDED IN �'`� ��� �`�.�
�
H-BURNER �
ACCESSORY �� " �"`'
KITI �. ¢
Fig. 4 WIRING SCHEMATIC
SWITCHING DEVICES RECOMMENDED GAUGE
WALL SWITCH, REMOTE OF WIRE
CONTROL, BARK CHIP SWITCH, WALL SWITCH & REMOTE
&PINECONE SWITCH CONTROL
GAS CONTROL
KNOB Mv-C VALVE WIRE MAXIMUM
SIZE LENGTH
0 m o 14 Gauge 100 Ft.
� 16 Gauge 64 Ft.
� � � � 18 Gauge 40 Ft.
0 O ° PILOT 20 Gauge 25 Ft.
aT � e � 22 Gauge 16 Ft.
GENERATOR
WALL SWITCH- (use installation instructions accompanying any other switching device)
1. To install a wall switch mount a standard 3" X 2" electrical box in wall near the fireplace. Run thermostat
wire (18-gauge wire) from the electrical box to the millivolt valve. At the valve, connect the lead wires to the
two outside terminals labeled "TH". On the switch, connect a lead wire to each terminal. (Fig.4)
2. Mount the wall switch to the electrical box and install cover plate.
* If installing a remote control attach the leads from the receiver to the same terminals as the wall switch on the MV-C.
LIGHTING INSTRUCTIQNS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly,a fire or explosion may
result causing property damage, personal injury or loss of life.
A. This appliance has a pilot, which must be lit by be necessa.ry to depress the knob slightly at the pilot
hand. When lighting the pilot, follow these position). Allow five minutes for any gas in the
instructions exactly. combustion chamber to escape (LP gas, which is
heavier than air, may require forced ventilation).
B. Before lighting smell all around the appliance area
for gas. Be sure to smell next to the floor because 2. Turn the gas control knob to the pilot position.
some gas is heavier than air and will settle on the
floor. 3. Push in on the gas control knob and light the pilot
immediately. Hold the knob down for one full minute
FOR YOUR SAFETY �ter lighting the pilot.
"What to do if vou smell gas" 4. When the gas control knob is released, the pilot
flame should continue to burn (if the pilot goes out;
* Do not try to light any appliance. repeat the above steps).
� Do not touch any electrical switch; do not use
any phone in your building. 5. Rotate the gas control knob from pilot to on
* Immediately call your gas supplier from a position (full counterclockwise position) to supply full
neighbor's phone. Follow the gas supplier's flow of gas ta main burner.
instructions.
* If you cannot reach your gas supplier, call the 6. Leaving the control knob in the full on position.
fire department. The main burner can now be controlled by the remote
control or wa11 switch. You can adjust the flame
C. Use only your hand to push in or turn the gas height by the control knob,if you turn it back towards
control knob. Never use tools. ff the knob will not the pilot posi�ion you will decrease the gas flow, in
push in or turn by hand, don't try to repair it. Call a �you will decrease the flame height.
qualified service technician. Forced or attempted
repair may result in a fire or explosion.
PILOT FLAME ADJUSTMENT
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service These controls are factory preset and will not normally
technician to inspect the appliance and to replace any require additional adjustment of the pilot flame. If
part of the control system and any gas control, which field adjustment of the pilot flame is required,remove
has been under water. the pilot adjustment cover screw to expose the
adjusting screw. Turn the adjusting screw clockwise
PILOT LIGHTING PROCEDURE reduce flame, or counterclockwise to increase flame.
Replace pilot adjustment cover screw and tighten
CAUTION: Make sure the wall switch and remote securely.
are in the off position before lighting the pilot.
l. Turn the gas control knob to the off position(it will