Loading...
HomeMy WebLinkAboutB14-0265 NOTE: THIS PERMIT MUST BE POSTED UN JOBSITE AT ALL TIMES ,. TOWh10F YAII, . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B14-0265 Project #: PRJ14-0312 Job Address: 1767 ALPINE DR VAIL Applied.....: 07/24/2014 Location......: Issued. . . : 09/11/2014 Parcel No....: 210312307008 OWNER 1767 ALPINE LLC 07/24/2014 2525 WEST END AVE STE 1500 NASHVILLE TN 37203 APPLICANT COMMERCIAL & RESIDENTIAL CON 07/24/2014 Phone: 970-688-1872 MATTHEW BOMER PO BOX 273 VAI L CO 81658 License: C000003222 CONTRACTOR COMMERCIAL & RESIDENTIAL CON 07/24/2014 Phone: 970-688-1872 MATTHEW BOMER PO BOX 273 VAI L CO 81658 License: C000003222 Description: windows,skylights,roof,siding,paint Occupancy: R-3 Type Construction: VB Valuation: $40,000.00 ....................,............__....,...........x.............,..,......,+...... FEE SUMMARY ......,..,,...x..,..,.....__,,,.........._.........._..........._.........__..... Building Permit-----------> $542.75 Bldg Plan Check----------> $352.79 Use Tax Fee-----------------------> $600.00 Electrical Permit---------> $0.00 Elec Plan Check-----------> $0.00 Restuarant Plan Review--------> $0.00 Mechanical Permit------> $0.00 Mech Plan Check---------> $0.00 Additional Fees--------------------> $0.00 Plumbing Permit--------> $0.00 Plmb Plan Check---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5.00 TOTAL PERMIT FEES--------------> $1,500.54 Payments-------------------------------> $1,500.54 BALANCE DUE------------------------> $0.00 ..........................................................».....,......................,,...........x.............,........�............�......._............___.........._._.,......... DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4:00 PM. combination permit_012811 � � - f #V����� 1 ..•.wwx��+++.>++.x.wx�x���,r�xwew+xr++xxwx���,rx.�:r..xxxxxxn�,+v.,+w..,r.�xxw�����,r,r...x+.��+e....w.wxxxxs.��xv.ew..,r«xxw,r+.+.+.,r,rwa.+�xx+,r.�.w....rw��++.,..e.wx���+v..,.+.,rx+.��,v,r.x.++.w,r,.,.,.,..+�ww CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit#: 614-0265 Address: 1767 ALPINE DR VAIL Owner: 1767 ALPINE LLC Location: ..................................................................................................................................................................................... combination permit_012811 i . � t V�1l� V� 1�� � *..,,**«„**,,..�.******.*.,..,******,****.****************�*.,*«**„**�****«..*******„******.,**..*************«****„*.,*****«*****.,*,,.****«**.***�****�**„ REQUIRED INSPECTIONS AND STATUSES Permit#: B14-0265 Address: 1767 ALPINE DR VAIL Owner: 1767 ALPINE LLC Location: *„****.**«*******�**«**„«**..**«*«*«**.*****************«***«**«*******«*«*,.***„*********.*************.,.,************,.******.******«******«********** Item: 00090 BLDG-Final Item: 00542 PLAN-FINAL combination permit_012811 � ***�**************�*************+***********�*****+*+***�***********************++****+***** TOWN OF VAIL, COLORADOCopy Reprinted on 09-11-2014 at 11:19:14 09/11/2014 Statement *****************************+*********************************************************+**** Statement Number: R140001424 Amount: $1, 147 .75 09/11/201411: 19 AM Payment Method:Credit Crd Init: CG Notation: visa matthew n bomer ----------------------------------------------------------------------------- Permit No: B14-0265 Type: COMBINATION BLDG PERMIT Parcel No: 2103-123-0700-8 Site Address: 1767 ALPINE DR VAIL Location: Total Fees: $1, 500. 54 This Payment: $1, 147.75 Total ALL Pmts: $1, 500.54 Balance: $0.00 ******+******************+****************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 542.75 UT 11000003106000 USE TAX 40 600. 00 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 ----------------------------------------------------------------------------- � Department of Community Development � 75 South Frontage Road �-��� �� �,r���.•::` � Vail, CO 81657 Te I: 970-479-2128 www.vailgov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm &sprinkler) _ �------ .___�... _.�.._- ..._,.,_ .-------- -------._ .____._ .�______..�. Pro�ect Street Address �� � --� Project#: `� �-� ,� � ' ��-— �� �l�?��� �Q,,��_ .t �'►��fiS , ` , ( ;(Number) (Street) (Suite#)A5',� DRB#: ���I�1l�c��`� ��- Building Permit#: � �� �-(���� � �Building/Complex Name: !Contractor Information Lot#: Block# Subdivision: Business Name:�aN(M�/tc'rl � I�S-r`�P.��r�1 ��c:sl. �l(' `, ...__ __ _._.... _ _ _, �J�K a. Work Class: New� Addition�) Alteration(� ;Business Address: R3 -------------- - ....... ..... . . ..- --..... . - ..- - - - .. City '✓/f��� State: l_e� Zip: �y��b Type of Building: Single-Family�) Duplex�) Multi-Family�) Contact Name: _��t� �i�jvV��+� ',�^ :Commercial � Other�) �7C� ��� �`�" ! �, ----�- .. .... ..,. ... .... _... _; Contact Phone: ---- ,--- ---- --- --. ,Contact E-Mail: �;��C'C �f C.�.,- �p�"� :Work Type: Interior�) Exterior� Both� --------- .....---- - � ........ ......... .....--..._..............., ', I hereby acknowledge that I have read this application,filled out = Valuation of ` ' in full the information required,completed an accurate plot plan, Work Included Plans Included Work ' and state that all the information as required is correct. I agree to '-- ---------------- ---------- --- - — ---- ------ ' comply with the information and plot plan, to comply with all Town ;Electrical Yes )No )Yes )No -- � � -- - � � - , - . I ordinances and state laws, and to build this structure according to _Mechanical �jYes �)No �)Yes �No the town's zoning and subdivision codes, design review ap- = ' proved,Internatio I Building and Residential Codes and other �Plumbing �Yes �)No �Yes �jNo ordinances of ow applicable thereto. � Buildmg )Yes )No Yes )No . ....... ... .......�._---�- -�_ �.. .... �... ..._��: ' ;X � ;Value of all work being performed: $ ��C�.0�� � 'Owner er's esentative Signature(Required) �(value based on IBC Sectio�109.3&IRC Section�os.$) �Electrical Square Footage � ' '---------------------p---------------------------------------------------------------------------------- ;Applicant Information : Detailed Sco e and Location of Work: ApplicantName: ��}��p�l�,�,-- � ��,7���� ��� -K ;Applicant Phone: �PrN•t� c�5 ce �e;�/[ ;��1��� � � �.��� b�.JS 1 l ;,��1��4J �9� ;Applicant E-Mail: �9 ' :Project Informati p 'Owner Name: __���� ��/�� S�j� , ;Parcel#' ����-'roZ.�°'�'70�? �� ;(For Parcel#,contact Eagle County Assessors Office at(970�28-8640 or visit ;www.eaglecounty.us/patie) `--°°..- - --._......--...____................... - - ° ° ° - - `''(u ~- se additional sheet if necessary) ' For Office Use O2nl : Date Received: Fee Paid: J���� Received From: /y I�,�f� � � � � � � Cash 'CJ�eck# � CC: Usa/�M�C� I�as�t�CC# � exp date; ��P JUL 2 4 2014 Auth# C7 ��� TOWN OF VA1L15-Mar- �2 _ *************************++*************************+*****************+****************++*** TOWN OF VAIL, COLORADO Statement �*�************************************+**************************************************** Statement Number: R140001059 Amount: $352.79 07/24/201402:27 PM Payment Method:Credit Crd Init: CG Notation: visa matthew n bomer ----------------------------------------------------------------------------- Permit No: B14-0265 Type: COMBINATION BLDG PERMIT Parcel No: 2103-123-0700-8 Site Address: 1767 ALPINE DR VAIL Location: Total Fees: $1, 500.54 This Payment: $352.79 Total ALL Pmts: $352.79 Balance: $1, 147.75 **********************************************+********************************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 352.79 ----------------------------------------------------------------------------- Department of Community Development 75 South Frontage Road TOWN OF VAII. ' vai�, co s�ss� Te I: 970.479.2128 www.vailgov.com Development Review Coordinator TRANSMITTAL FORM Use this form when submitting additional information for planning applications or building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance of the permit. Application/Permit#(s)information applies to: Attention: Q Revisions LI�iNC� Y�1-!U�� �—�L� a �,j_��,. �Response to Correction Letter �attached copy of correction letter �' ` (� f�_� j�� Q Deferred Submittal .��lJ��i.J �'z ti�� G 1'� � ((�Other Project Street Address: � �_����N� �� (Number) (Street) (Suite#) Building/Complex Name: Description of Transmittal/List of Changes, Items Attached: (.-vl�TI�L C9� �� '-�c1 C�G.�.� V/1 f t1� Applicant Information � � (architect,contractor,ownerlowner's rep) S � �� �`l . Contact Name: ���('�M,�� Address: -�c7 ��;�[ � J�i City lf/4-� t State: '�c�Zip: �� Contact Name: 1�1� 7/ �t�cM C� (use additional sheet if necessary) Contact Phone: � �� G �3 � i�7� Building Permits: Revised ADDITIONAL Valuations(Labor&Materials) Contact E-Mail: /�� C✓�r'��/�(� , C �✓� (DO NOT include original valuation) I hereby acknowledge that I have read this application,filled out Building: $ �� in full the information required,completed an accurate plot plan, � and state that all the information as required is correct. I agree to Plumbing: $ comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according Electrical: $ to the town's zo �ng and s division codes, design review ap- proved,Intern ional Buii ng and Residential Codes and other Mechanical: $ ordinances the Tow applicable thereto. X � -- - Total: $0 Owner/Owner's Re sentative Signature(Required) Date Received: p � � � �� For Office Use Only: � Fee Paid: ��� ��14 Received From: Cash Check# CC: Visa/MC Last 4 CC# exp.date: ��V V N C�F VA I L Authorization# S/22/2014 Home Alpine SnowGuards Snow Reten6on Systems for just about any roof type. Yc HOME OUR PRODUCTS PLACE ORDER REQUEST LAYOUT WHAT'S NEW PAQS RELATED LINKS CONTACT US RENEWABLE ENERGY Pad Style Snow Guard Calculator/Estimator Today is Fr(day,August 22,2014 03:47 PM EST �round Snow 4oad(Pg): 75 psf For your Alpine Roof project: Roof Pitch:(�r:12) 12:12 The rafter length is> 15'you witl need to install the standard three-row pattern and 3 supplemental rows- refer to the illustration below.The calculation is based Eave Lengtl�: 30 on 12 snow 9uards per roofing square. Ratter Length: 20 Ridge �__�.�_.._._�.__�..��_--�-.---�--_ Roofing Squares: 6 ' I � 1 I I � l i t_� [ � I � 1 � Top�0'of rafter 1 I _i 1: I L 1-- _-L __1 does not Snow Quards per squaro: iz l i 1 T T i T 1 generally ! �L�_!�1�1� 1�_1 TL�1 require snow Supplemental Rows: 3 � � � � � � � i � � � � � � i � I in�extreme� I 1 I } � � 1 � � snow�Qad Number of Snow Guards �Z � � � 1 i I � i � I � I � I � � � areas(>75 psfl. Needed: � ( � r � ' ' , ( ( i 1 � 1 C P� I � 1 t 1 I''� i � Rernairrng snow Use the button below to go back and change your numbers. � t-� ` 1 I_� I [ � '.�_I_i_f � �severY Recalculate �I 1 SPaCed Startx►g l ( 3 courses above l � l � l � f � l � l � ! � i I bottompanem. Print this page,add your contact informatlon,and email[o � � �' � � � �' ? 48"on center, r—� info�alpinesnowguards.com. ( ! ! ' I I I � 1 y�� � eve.ryy 3 wurses I have read and agree to Alpine's Terms of Use. ( �'�1 � � � ( � � I � 1 � altile. ��- � � � � � � � � � � � �� � � r� � � �,.� � � t;� Siandard3-row I 1 l �*-24'--�I 1 I 1 P��.2a•on t� I F', i F 1 F' ' center wim the � r i i--�,� �,�I �I middie row �Eave �ered 12°. Home�Contact Us�Terms of Use�Snow Guard layouUQuote Request�Snow Guards�Pad-Style Snow Guards�Pipe�Style Snow Guards Clamp-to-Seam Snow Guards�S-5!Cobrgard��S-5!SnoRaiVSnoFenceO�Snow Guard FAQs t Employee Login�Client Login http:Ucalculator.aipinesnowguards.com/calculator/pad�roc i/1 , • --- ------- Detailed Quote �T B Alpine Lumber � � 111 East Chambers Raod �� Eagle,CO 81631 n 970-328-6306 (���.?��e �i�•; www.m2o.com Project IMormation Project: ALEX ORBISON RES. .32 ProJect ID: 648 Sales Rep: Administrator Created Date: 06/19/2014 Delivery/Plckup: Delivery Modifled Date: OS/05/2014 Print Date: 08/05/2014 Customer: ALEX ORBISON PO: 32025717 Terms: Est.Delivery: Comments: (After Receipt ot Order) I _ I BIIQng Information Shfpping Information � Customer Name: � Jobslte Contact: Address: Address: Customer Phone: Contact Phone: Fax: Fax: (Select Preference) Email: Email: Manufacturer. Milgard Item: 0001 Location: REAR NORTH WALL QuaMlty: 4 Tuscany,8520T,DC,RO 48"x 48" UF:0.3,SGC:0.25,VLT:0.47 664.64 Foam Spacer 49.80 Item Total: $ 714.44 Fin Plac:ement:1 3/8"Setback;Hinge Side:Left/Right;Euterior Finish: Item Quantity Totsl: $ 2857.76 White;Interior Finish:White;Glazing:Dual Glazed(Insulated Glass); Outer Giass Lite Option:SunCoat Low-E;Inner Glass Lfte Option:Clear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W: 12 5/16"H:42 15/16"SQ:3.67 CPD:MIL-A-227-02678-00001 Line Item Comments: Customer Approval: Initials a,ae io: soe � or 8 OB/OS/2014 _ .. � � Manufacturer: Milgard Item: 0002 Location: REAR WEST WAIL Quantlty: 3 Tuscany,8520T,DC,RO 48"x 36" UF:0.3,SGC:0.25,VLT:0.47 617.31 Foam Spacer 41.42 Item Total: $ 658.73 Fin Pfacement:1 3/S"Setbadc;Hinge Side:LefURight;Exterior Finish: ftem Quantity Total: $ 1976.19 White;Interior Finish:White;Glazing:Dual Glazed(Insulated Glass); Outer Glass Lite Option:SunCoat Low-E;Inner Glass Lite OpUon:Glear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fiberglass mesh;Breather Tubes:Yes;Clear OpeNng W: 12 5/16"H:30 15/16"SQ:2.65 CPD;MIL-A•227-02678-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0003 Locatlon: EAST WALL DINING QuanUty: 1 Tuscany,8225T,DH,RO 36"x 56" UF:0.3,SGC:0.27,VLT:0.52 358.45 Gas Filled:Argon 9.86 EdgeGardMAX 22.19 item Total: $ 390.50 Fin Placement:1 3/8"Setbadc;Horizontal Vent Set:28";Vent Height: Item�uantlty Totai: $ 390.50 X One HaK;Exterior Finish:White;Interior Finish:White;Glazing:Dual Glazed(Insulated Giass);Outer Glass Lite Option:SunCoat Low-E; Inner Giass Lite Option:Clear;Glass Thfdc 1:3/32";Glass Thick 2: 3/32";Spacer Type:EdgeGardMAX;Gas Filled:Argon;Screen:Standard X with Fiberglass mesh;Clear Opening W:31 1/4"H:20"SQ:4.34 CPD: MIL-A-234-01562-00001 Line Item Comments: Customer Approval: Inftials Manufacturer: Milgard Item: 0004 Locatlon: LOFT WEST Quantlty: y Tuscany,8420T,FA,RO 48"x 20 1/2" UF:0.3,SGC:0.19,VLT:0.44 304.22 3/32"SunCoatMAX and 3/32"Clear 6.90 Foam Spacer 23.67 ttem Total: $ 334.79 Fin Piacement:t 3/8"Setbadc;EMerior Finish:White;IMerior Finish: Item Quantity Total: $ 334.79 White;Glazing:Dual Glazed(Insulated Glass);Outer Glass Lite Option: SunCoatMAX;Inner Glass Lite OpUon:Ciear;Glass Thick 1:3/32"; Giass 7hidc 2:3/32";Spacer Type:Foam;Screen:Standard wfth Fiberglass mesh;Breather Tubes:Yes;CPD:MIL-A-226-02706-00001 Extensfon pole&hex adapter may be needed if Awning is out of reach. Line Item Comments: Gustomer Approval: Initials o�ae iD: saa 2 a a oa�os�zo+a Manufacturer: Milgard Item: 0005 Location: LOFT EAST Quantity: 1 Tuscany,8420T,FA,Net 45"x 20" UF:0.3,SGC:0.19,VLT:0.44 304.22 3/32"SunCoatMAX and 3/32"Clear 6.41 Foam Spacer 23,17 Item Total: $ 333.80 Fin Placement:1 3/8"Setback;EMerior Finish:White;Interior Finish: ftem(ivantity Total: $ 333.80 White;Glazing:Dual Glazed(Insulated Glass);Outer Glass Lite Option: SunCoatMAX;Inner Glass Lite Optfon:Ciear;Glass Thick 1:3/32"; Glass thick 2:3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;CPD:MIL-A-226-02706-00001 Extension pole&hex adapter may be needed if Awning is out of reach. Line Item Comments: Customer Approval: Initials Manufacturer: Milgazd Item: 0006 Location: KITCHEN Quantity: 1 Tuscany,8420T,FA,Net 49"x 21 1/2" UF;0.3,SGC:0.19,VLT:0.44 353.03 3/32"SunCoatMAX and 3/32"Ciear 7,40 Foam Spacer 25.15 Item Total: $ 385.58 Fin Placement:1 3/8"Setback;Exterior Finish:White;lnterior Finish: Item Quantity Total: $ 385.58 White;Glazing:Oual Glazed(Insulated Glass);Outer Giass Lite Option: SunCoatMAX;inner Glass Lite Option:Clear,Glass Thick 1:3/32"; Glass Thidc 2:3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;CPD:MIL-A-226-02706-00001 Extension pole&hex adapter may be needed if Awning is out of reach. Line item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0007 Locatlon: FRONT UNIT SOUTH KITCHEN Quantity: 1 Tuscany,8120T,HV,RO 36"x 24" UF:0.32,SGC:0.2�,VLT:0.49 178.98 3/32"SunCoatMAX and 3/32"Clear 5.92 Foam Spacer 29.p9 Item 7ota1: $ 213.99 Fin Placement:1 3/8"Setback;Sliding Direction:OX;EMerior Finish: Item Quantity Total: $ 213.99 X White;Interior Finish:White;Glazing:Dual Glazed(Insulated Glass); Outer Glass Lite Option:SunCoatMAX;Inner Glass Lfte Option:Clear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fiberglass mesh;Breather Tubes:Yes;Ciear Openirig W: i6 3/t6"H:20 1/2"SQ:2.16 CPD:MIL-A-224-03149-00001 Line Item Comments: Customer Approval: Initials Quote ID: 648 3 Of B O8/O5/2014 Manutacturer: Milgard Item: 0008 Locatlon: SOUTH UNIT WEST LIVING Quantlty: 1 Tuscany,8225T,DH,RO 42"x 48" UF:0.3,SGC:0.2,VLT:0.48 350.56 3/32"SunCoatMAX and 3/32"Ctear 13.31 Gas Filled:Argon 9.86 EdgeGardMAX 23.17 kem Totat: $ 396.90 Fin Placement:1 3/8"Setbadc;Ho�izontai Vent Set:24";Vent Height: ftem Quantity Total: $ 396.90 X One Half;Exterior Finish:White;Interior Finish:Whfte;Glazing:Dual Glazed(Insulated Glass);Outer Glass l.ite Option:SunCoatMAX;Inner Glass Lite Option:Clear;Glass Thick 1:3/32";Glass Thick 2:3/32"; Spacer Type:EdgeGardMAX;Gas Filied:Argon;Screen:Standard with � Fiberglass mesh;Clear Opening W:371/4"H:16"SQ:4.14 CPD: M I L-A-234-01598-00001 Line Item Comments: Customer Approvak Initials Manufacturer. Milgard Item: 0011 Locatlon: SOUTH UNIT SOUTH WALL LIVING QuanUty: 1 SUB UNIT 1 -Tuscany,8225T,DH,Net 41 1/2"x 39 1/2" UF:0.3,SGC:0.2,VLT:0.48 333.31 NFS:124 1/2"x 39 1/2" SUB UNIT 1 -3/32"SunCoatMAX and 3/32"Clear 11.34 SUB UNIT 1 -Gas Filled:Argon 8.38 SUB UNIT 1 -EdgeGardMAX 21.69 SUB UNIT 2-Tuscany,82257,DH,Net 41 1/2"x 391/2" UF:0.3,SGC:02,VLT:0.48 333.31 SUB UNIT 2-3/32"SunCoatMAX and 3/32"Clear 11.34 SUB UNIT 2-Gas Filled:Argon 8.38 SUB UNIT 2-EdgeGardMAX 21.69 SUB UNIT 3-Tuscany,8225T,DH,Net 41 1/2"x 39 1/2" UF:0.3,SGC:0.2,VLT:0.48 333.31 SUB UNIT 3-3/32"SunCoatMAX and 3/32"Clear 11.34 SUB UNIT 3-Gas Filled:Argon 8.38 SUB UNIT 3-EdgeGardMAX 21.69 COMPOSITE:Total Combinatbn Charge 0.00 DHSP x x x Item Total: $ 1124.16 Fin Placement:1 3/8"Setback;Exterior Finish:White;Interior Finlsh: Item Quantity Total: $ 1124.16 W hfte; Even though the diagram of the grids may nat line up exacUy, manufacturer will line up the grids when being buitt. "'Verify composke coMiguration size availability and pricirig with your Milgard location. Composite�nfiguratlons exceeding 40 sq.ft.may require field glazing. Line Item Comments: Customer Approval: Initials Sub Component Item: 1 RO Size.42`W x 40'H Nat Size=41 1/2'W x 39 7/Y H Sub Component Item Total:$ 374.72 Fin Placeme�t:t 3/8"Setback;Horizontel Vent Set: Sub Component Item Quantity Totel:$ 374.72 20";Vent Height:One HaH;Exterior Finish:White; Interior Finish:Whfte;Giazing:Duai Cilazed(Insulated Glass);Outer Glass L'Re Oprion:SunCoatMAX;Irmer Glass Lite OpUon:Clear;Glass Thick 1:3/32";Glass Thick 2:3l32";Spacer Type:EdgeGardMAX;Gas Filied:Argon;Screen:Standard with Fibergt�s mseh; Gear Opening W:37 1/4"H:12'SQ:3.10 CPD: MIL-A-234-01598•00001 �uote ID: 648 4 Of 8 08lOS/2014 Sub Component Item: 2 RO Size�42'W x 40'H Net Size.41 1/2'W x 391/2"H Sub Component Item Total:$ 374.72 Fln Placement:1 3/8"Setback;Horizon�vent sec: gub Component Item Quandty Total:$ 374.72 20";Vent Height:Ooe Halt;Exterior Fnish:White; Interior Fnish:W hite;Giazing:Dual Glazed(Insulated Glass);Outer Glass Ute Option:SunCoatMAX;Inner Cilass Lite Opdon:Clear;Glass Thidc t:3/32";Glass Thick 2:3/32";Spacer Type:EdgeGardMAX;Gas Filled:Argon;Screen:Standard with Fiberglass mesh; Gear Opening W:37 7/4"H:12"SQ:3.10 CPD: M I L-A-234-01598-00001 3ub Component Rem: 3 RO Sze.42'W x 49'H Net Sixe:41 1/2"W x 391/Y H Sub Component Item Total:$ 374.72 Fin Placement:1 3/8'Setback;Horizontai VeM Set: Sub CompOftBnt Item QuanUty Total:$ 374.72 20";Vent HeigM:One Hatf;Exterior Finish:WhRe; IMeria Finfsh:White;Glazing:Dual Glazed(Insulated Glass);Outer Glass Lite OpHon:SunCoatMAX;Inner Glass lke OpNom Clear;Glass Thick 1:3/32';Glass Thick 2:3/32";Spacer Type:EdgeGardMAX;Gas Filied:Argon;Screen:StandaM with Fiberglass mesh; Clear Opening W:37 1/4'H:12"SQ:3.10 CPD: MIL-A-234-01598-00001 Manufacturer. Milgard Item: 0013 Location: SOUTH UNIT EAST WALL LIYING Quantity: 1 SUB UNiT 1 -Tuscany,8225T,DH,RO 42"x 40" UF:0.3,SGC:0.2,VLT:0.48 333.31 R0:84"x 40" SUB UNIT 1 •3/32"SunCoatMAX arid 3/32"Clear 11.34 SUB UNIT t-Gas Fiiled:Argon 8.38 SUB UNIT 1-EdgeGardMAX 21.69 SUB UNIT 2-TusCany,8225T,DH,RO 42"x 40" UF:0.3,SGC:0.2,VLT:0.48 333.31 SUB UNIT 2-3/32"SunCoatMAX and 3/32"Ciear 11.34 SUB UNIT 2-Gas Filled:ArgOn 8.38 SUB UNIT 2-EdgeGardMAX 21.69 COMPOSITE:Total Combinatlon Charge 0.00 DHSP Rem Total: $ 749.44 X X Fin Placement:1 3/8"Setbadc;Exterior Finish:White;interior Finish: ftem fivantity Total: $ 749.44 X X Whfte; Even though the dlagram of the grids may not line up exactly, manufacturer will Iine up the grids when being buitt. "Verify composite coMiguration size availability and pricing with your Milgard locatbn. Composfte configurations exceedir�g 40 sq.ft.may requlre field glazing. Line Item Comments: Customer Approval: Initials Quote ID: 648 5 Of 8 OB/OS/2014 Sub Component Item: � RO Size.42'W x 40'H Net Size�41 7/2'W z 39 7/Y H Sub Component Item Totai:$ 374.72 Fin Placeme�t:t 3i8•Setback;Hor�zonal vent Set: Sub Component Item Quantity Total:$ 374.72 20";Vent Height:One Half;F_xteria Fnish:White; Interior Finish:Whfte;Glazing:Dual Glazed(Insulated Glass);Outer Glass Lke Option:SunCoatMAX;Inner Glass Lfte Option:Clear;Giass Thick t:3/32";Glass Thick 2:3/32";Spac�Type:EdgeGardMAX;Gas Filled:Argon;Screen:Standard with Fiberglass mesh; Ciear Opening W:37 1/4"H:12"SQ:3.10 CPD: MIL-A-234•01598-00001 Sub Component Item: 2 RO Size a 42"W x 40'H Net Size.41 1/2'W x 39 1/2"H Sub Component item Totel:$ 374.72 Rn Ptacement:1 3/8^setnack;Hortzonca�vem sec: Sub Component Item Quantiry Total:$ 374.72 20";Vent Height:One Half;Euterfor Finish:White; hrterior Finish:W hke;Glazing:Duai Glazed Qnsulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Optioo:Clear,Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:EdgeGardMAX;Gas Filled:Argon;Screen;Standard with Ffberglass mesh; Clear Opening W:37 1/4"H:12"SQ:3.10 CPD: MIL•A-234•01598-00001 Manufacturer: Milgard Item: 0014 �ocatlon: SOUTH UNIT EAST WALL DINING Quantity: 1 Tuscany,8225T,DDH,RO 52"x 40" UF:0.3,SGC:02,VLT:0.48 619.28 3/32"SunCoatMAX and 3/32"Clear 13.81 Gas Filled:Argon 10.35 EdgeGardMAX 32.05 Rem Total: $ 675.49 X X Fin Placement:1 3/8"Setbadc;Horizontal Vent Set:20";Vent Height: item Quantity Total: $ 675.49 One Half;Exterior Finish:White;Interior Finish:White;Glazing:Dual Glazed(Insulated Giass);Outer Glass Lite Option:SunCoatMAX;Inner X X Giass Lite Option:Clear,Glass Thick 1:3/32";Glass Thick 2:3/32"; Spacer Type:EdgeGardMAX;Gas Flled:Argon;Screen:Standard with Fiberglass mesh;Clear Opening W:21 1/4"H:12"SQ:1.77 CPD: MIL-A-234-01598-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0015 Locatlon: SOUTH UNIT UPPER BEDROOMS t]uantity: 2 Tuscany,8120T,HV,RO 52"x 40" UF:0.32,SGC:0.21,VLT:0.49 284.99 3/32"SunCoatMAX and 3/32"Clear 13.81 Foam Spacer 45.85 Item Total: $ 344.65 Fin Placement:1 3/8"Setback;Sllding Directlon:XO;Exterior Finish: ttem Quantlty Total: $ 689.30 X White;Interior Finish:White;Glazing:Dual Glazed(insulated Glass); Outer Glass Lite Option:SunCoatMAX;Inner Glass LRe Option:Clear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W: 23 3li6"H:36 1/2"SQ:5.88 CPD:MIL-A-224-03149-00001 Line Item Comments: Customer Approval: Initials Quote ID: 648 8 Of B OSl05/2014 Manufacturer: Milgard Item: 0016 Locatlon: SOUTH UNIT UPPER BATHROOM Quantity: 1 Tuscany,8120T,HV,RO 52"x 40" UF:0.32,SGC:0.21,VLT:0.49 284.99 1/8"SunCoatMAX Tempered a�d 1/8"P516(Standard Obscure)Tempered 210.04 Foam Spacer 45.85 item Total: $ 540.88 Fin Placement:1 3/8"Setback;SI'�ding Direction:XO;Exterior Finish: ftem Quantlty Total: $ 540.88 X White;Interior Finish:White;Glazing:Dual Glazed(Insulated Glass); Tempered:Ail;Outer Glass Lite Option:SunCoatMAX;inner Glass Lite Option:P516(Staridard Obscure);Glass Thidc 1:1/8";Glass Thick 2: 1/8";Spacer Type:Foam;Screen:Standard with Fiberglass mesh; Breather Tubes:Yes;Clear Openirg W:23 3/i6"H:36 1/2"SQ:5.88 STC:30 CPD:MIL-A-224-03151-00001 Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0017 Locatlon: SOUTH UNIT LaFT QuanUty: 2 Tuscany,8225T,DH,RO 24"x 36" UF:0.3,SGC:0.2,VLT:0.48 249.49 3/32"SunCoatMAX and 3/32"Ciear 5.92 Gas Filled:Argon 4.44 EdgeGardMAX 14.79 Item Total: $ 274.64 X Fin Placement:1 3!8"Setbadc;Horizontal Vent Set:18";Vent Height: Item QuantityTotal: $ 549.28 One Half;Exterior Finish:White;Interior Finish:White;Glazing:Dual Giazed(insulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:Clear;Glass Thidc 1:3/32";Glass Thick 2:3/32"; X Spacer Type:EdgeGardMAX;Gas Filled:Argon;Screen:Standard with Fiberglass mesh;Clear Opening W:19114"H:10"SQ:1.34 CPD: MIL-A-234-01598-00001 line Item Comments: Customer Approval: Initiais OtherCharges: SUBMITTED BY: 3U6 TOTAL(taxable):$ 11218.06 SUB TOTAL(non-taxable):S 0.00 ACCEPTED BY: TAXES( 4.A00 %):; 493.59 DATE: GRAND TOTAI.:$ 11711.66 Notl�(H any): For warranry Informatfon please vislt www.mllgard.com/care-and-warranty! Please note that actuai NFRC energy vaiuea may vaty from those reported in CTB quote due to vaNations that may occur durfng the manufacturing process. In most cases varlatfona will be minimal. Ptease contact your Mllgard location wkh questlons or concerns regarding this poternial vaNatlon. Handing Is viewed from outside looking In"X"indicates operable panel."O"fndicates fixed panel. 21 Itsms. Quote ID: 848 � Of B 08/OS/2014 , , , . ADDITIONAL tNFORMATiON: Thls Quote Is valid ior 30 days.This is an estlmate only and does not include dellvery charges. 1 understand that this order witl be placed according to these specificattons and is non•refundabte. Quote ID: 648 8 Of B 08/OS/20i4 _ _ --_—. ____ _. _ Detailed Quote CT B Alpine Lumber a � 111 East Chambers Raod � • Eagle,CO 81631 970-328-6306 ��-�tr2��.��ce: �iev�•� www.m2o.com �Project Information ' Project: ORBISON RES. Project ID: 613 � Sales Rep: Administrator Created Date: U6/19/2014 � Delivery/Plckup: Delivery Modlfled Date: 06/19/2014 � Print Date: 06/19/2014 Customer: ALEX ORBISON P�' � Terms: Est.Delivery: , i Comments: (After Recefpt of Order) i I I_---- ---------- --- — � Billing Information Shipping Information � Customer Name. Jobsite Contact: Address: Address: � Customer Phone: Contact Phone: ! Fax: Fax: (Select Preference) ; Emall: Email: i ��-- ---L-- Manufacturer: Milgard Item: 0001 Location: REAR NORTH WALL Quantlty: 4 Tuscany,8520T,DC,Net 48"x 48" UF:0.3,SGC:d.25,VLT:d.47 664.64 Foam Spacer 50.29 Item Total: $ 714.93 Fin Placement:1 3/8"Setback;Hinge Side:LeftlRight;Exterior Finish: Item Quanttty Total: $ 2859.72 White;Interior Finish:White;Glazing:Dual Glazed(insulated Glass); Outer Glass Lite Option:SunCoat Low-E;Inner Glass Lite Option:Clear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fibergiass mesh;Breather Tubes:Yes;Clear Opening W: 12 9/16"H:43 7/16"SQ:3.79 CPD:MIL-A-227-02678-00001 C�� Line Item Comments: Customer Aqproval: __ Initials LS � � L �J � ctuoie�o: e�a � rn e �, os�� i � v JUL 2 4 2014 TOWN C)F VAIL � � � � �� Manufacturer: Milgard Item: 0002 Locatlon: REAR WEST WALL Quantity: 3 Tuscany,8520T,DC,Net 48"x 36" UF:0.3,SGC:0.25,VLT:0.47 617.31 Foam Spacer 42.40 Item Total: $ 659.71 Fin Placement:1 3/8"Setback;Hinge Side:LefURight;Exterior Finish: Item Quantity Total: $ 1979.13 White;�nterior Finish:White;Glazing:Dual Glazed(Insulated Glass); Outer Glass Lite Option:SunCoat Low-E;Inner Glass Lite Option:Ciear; Glass Thick 1:3/32";Giass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W: f�\ 12 9/16"H:31 7/16"SQ:2.74 CPD:Mil-A-227-02678-00001 I / �••- Line item Comments: Customer Approvai: Initials Manufacturer: Miigard Item: 0003 Locatlon: EAST WALL DINING �uantity: 1 Tuscany,8225T,DH,Net 35 3/4"x 56" UF:0.33,SGC:0.28,VLT:0.52 358.45 Foam Spacer 44.87 Item Total: $ 403.32 Fin Piacement:1 3/8"Setback;Horizontai Vent Set:28 1/4";Vent Height: Item QuantltyTotal: $ 403.32 X One Half;Exterior Finish:White;Interior Finish:White;Glazing:Dual Giazed(insulated Giass);Outer Glass Lite Option:SunCoat Low-E; inner Glass Lite Option:Clear;Giass Thick 1:3/32";Glass Thidc 2: 3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh; X Breather Tubes:Yes;Ciear Opening W:31 1/2"H:20 1/4"SQ:4.43 CPD:MIL-A-234-01938-00001 f � \ Line item Comments: Customer Approval: _____ / ) Initials t,�� < Manutacturer Milgard Item: 0004 Locatlon: LOFT WEST Quantity: 1 Tuscany,8420T,FA,Net 47 1/2"x 20" UF:0.3,SGC:0.19,VLT:0.44 304.22 3/32"SunCoatMAX and 3/32"Clear 6.90 Foam Spacer 23.67 Item Total: $ 334.79 Fin Piacement:1 3/8"Setback;Exterior Finish:White;Interior Finish: Item Quantity Total: $ 334.79 White;Glazing:Dual Giazed(insulated Glass);Outer Glass Lite Option: SunCoatMAX;Inner Glass Lite Option:Clear;Glass Thick 1:3/32"; C �� Giass Thick 2:3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;CPD:MIL-A-226-02706-00001 Extension pole&hex adapter may be needed if Awning is out of reach. Line item Comments: Customer Approval: _ Initials Quote ID: 673 2 Of 8 O6/19/2014 Manufacturer: Milgard Item: 0005 Location: LOFT EAST ���tY� 1 Tuscany,8420T,FA,Net 47 1/2"x 20" UF:0.3,SGC:0.19,VLT:0.44 304.22 3/32"SunCoatMAX and 3/32"Clear 6.90 Foam Spacer 23.67 Item Total: $ 334.79 Fin Placement:1 3/8"Seffiack;Exterior Finish:White;interior Finish: Item Quantity Total: $ 334.79 White;Glazirig:Duai Glazed(Insulated Glass);Outer Glass Lite Option: C �� SunCoatMAX;inner Glass Lite Option:Clear;Glass Thick 1:3/32"; Glass Thick 2:3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;CPD:MIL-A-226-02706-00001 Extension pole&hex adapter may be needed if Awning is out of reach. Line Item Comments: Customer Approval: Initials Manufacturer: Milgard Item: 0006 Location: KITCHEN �uantfty: � Tuscany,8420T,FA,Net 49 1!2"x 22" UF:0.3,SGC:0.19,VLT:0.44 353.03 3/32"SunCoatMAX and 3/32"Clear 7.40 Foam Spacer 25.15 Item Total: $ 385.58 Fin Placement:1 3/8"Setbadc;Exterior Finish:White;Interior Finish: Item Quantity Total: $ 385.58 White;Glazing:Dual Glazed(Insulated Giass);Outer Glass lite Option: \ SunCoatMAX;Inner Glass Lfte Option:Clear;Giass Thick 1:3/32"; � ; � Glass Thick 2:3/32";Spacer Type:Foam;Screen:Standard with 1' � Fiberglass mesh;Breather Tubes:Yes;CPD:MIL-A-226-02706-00001 Extension pole&hex adapter may be needed if Awning is out of reach. line Item Comments: Customer Approval: Initials Manufacturer: Miigard Item: 0007 Location: FRONT UNIT SOUTH KITCHEN Quantity: 1 Tuscany,8120T,HV,RO 36"x 24" UF:0.32,SGC:0.21,VLT:0.49 178.98 3/32"SunCoatMAX and 3/32"Clear 5.92 Foam SpaCer 29.09 Item Total: $ 213.99 Fin Piacement:1 3/8"Setback;Sliding Direction:OX;Exterior Finish: Item Quantity Total: $ 213.99 X White;interior Finish:White;Glazing:Dual Glazed(Insulated G�ass); Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:Clear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: � A� Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Openirg W: ;o` 15 3/16"H:20 1/2"SQ:2.16 CPD:MIL-A-224-03149-00001 Line Item Comments: Customer Approval: Initials Quote ID: 613 3 Ot 8 08/18/2014 Manufacturer: Milgard Item: 0008 Locatlon: SOUTH UNIT WEST LIVING �uantlty: 1 Tuscany,8225T,DH,R042"x 48" UF:0.33,SGC:0.21,VLT:0.48 350.56 3/32"SunCoatMAX and 3/32"Clear 13.31 Foam Spacer 45.85 Item Total: $ 409.72 Fin Placement:1 3/8"Setbadc;Horizontal Ve�t Set:24";Vent Height: Item Quantlty Total: $ 409.72 X One Half;Exterior Finish:White;Interior Finish:Whfte;Glazing:Dual Giazed(Insulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Giass Lite Option:Clear;Giass Thick 1:3/32°;Glass Thick 2:3/32"; Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather X Tubes:Yes;Ciear Opening W:371/4"H:16"SO:4.14 CPD: MIL-A-234-01974-00001 �H� Line Item Comments: Customer Approval: �,� Initials Manufacturer: Milgard item: 0011 Location: SOUTH UNIT SOUTH WALL LIVING Qua�tlty: 1 SUB UNIT 1 -Tuscany,8225T,DH,Net 41 1/2"x 39 1/2" UF:0.33,SGC:0.21,VLT:0.48 333.31 NFS:1241/2"x 39 1/2" SUB UNIT 1 -3/32"SunCoatMAX and 3/32"Clear 11.34 SUB UNIT 1 -Foam Spacer 42.90 SUB UNIT 2-Tuscany,8225T,DH,Net 41 1/2"x 391/2" UF:0.33,SGC:021,VLT:0.48 333.31 SUB UNIT 2-3/32"SunCoatMAX and 3/32"Ciear 11.34 SUB UNIT 2-Foam Spacer 42.90 SUB UNIT 3-Tuscany,8225T,DH,Net 41 1/2"x 39 1/2" UF:0.33,SGC:0.21,VLT:0.48 333.31 SUB UNIT 3-3/32"SunCoatMAX and 3/32"Clear 11.34 SUB UNIT 3-Foam Spacer 42.90 COMPOSITE:Total Combination Charge 0.00 DHSP x x x Item Total: $ 1162.65 Fin Placement:1 3/8"Seffiack;Exterior Finish:White;Interior Finish: Item Quantity Total: $ 1162.65 W hite; J �� Even though the diagram of the grids may not line up exactly, �� manufacturer will line up the grids when being built. '•Verify composfte configuration size avaiiabiliry and pricirig with your Miigard location. Composite configurations exceeding 40 sq.ft.may require fiekl glazing. Line Item Comments: Customer Approval: Initials Sub Component Item: 1 RO Size�42"W x 40"H Net Size.41 1/2"W x 39 1/2"H Sub Component Item Total:$ 387.55 Fin Placement:1 3/8^Semacic;Horizonrai venc set: Sub Component Item Duantity Total:$ 387.55 20";Vent Height:One Half;Exteria Finish:White; IMerior Finish:White;Glazing:Dual Glazed(Insulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:Clear;Glass Thick t:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen:Standard with Flberglass mesh;Breffiher Tubes:Y�;Clear Opening W:37 1/4"H:12"SQ:3.10 CPD: MIL-A-234-07974-00001 Quote ID: 613 4 Of 8 06/19/2014 Sub Component Rem: p RO Size�42"W x 40"H � Net Size�41 1/2"W x 39 7/2'H Sub Component Item Total:$ 387.55 Fin PlacemeM:1 3/8"Setback;Horizon�vent Set: Sub Component Item Duantity Total:$ 387.55 20";Vent Hefght:One Half;EMerior Finish:W hite; Interior Finish:White;Glazing:Dual Glazed(Insuiated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:Ciear;Glass Thick 1:3/32";(31ass Thick 2:3l32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W:37 1/4°H:12"SQ:3.10 CPD: MIL-A-234-01974-00001 Sub Component Item: 3 ii0 Size e 42'W x 40"H Net Size.41 1/2'W x 39 1/2"H Sub Component Item Total:$ 387.55 Fin Placement:l 3/8"Setback;Horizontal Vent Set: SUb COmponent Item Quantlty TOtal:$ 387.55 20";Vent Height:One Half;Exteria Finish:White; Interior Finish:White;Glazirig:Dual Glazed(Insulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lfte Option:Clear;Glass Thfck 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W:37 1/4'H:12"SQ:3.10 CPD: MIL-A-234-0197400001 Manufacturer: Milgard Item: 0013 Locatlon: SOUTH UNIT EAST WALL LIVING Quandty: 1 SUB UNIT 1 -Tuscany,8225T,DH,RO 42"x 40" UF:0.33,SGC:0.21,VLT:0.48 333.31 R0:84"x 40" SUB UNIT 1 -3l32"SunCoatMAX and 3/32"Clear 11.34 SUB UNIT 1 -Foam Spacer 42•90 SUB UNIT 2-Tuscany,8225T,DH,RO 42"x 40" UF:0.33,SGC:0.21,VLT:0.48 333.31 SUB UNIT 2-3/32"SunCoatMAX and 3/32"Ciear 11.34 SUB UNIT 2-Foam Spacer 42•90 COMPOSITE:Total Combination Charge 0.00 DHSP Item Total: $ 775.10 X X Fin Placement:1 3/8"Setback;Exterior Finish:White;Interior Finish: Item Quantlty Total: $ 775.10 X X White; ��� Even though the diagram of the grids may not line up exactly, manufacturer will line up the grids when being buiit. "Verify composite configuration size availability and pricing with your Miigard location. Composite configurations exceeding 40 sq.ft.may require field glazing. Line Item Comments: Customer Approvai: Initials Sub Component Rem: t RO Size-42"W x 40"H Net Size�41 1/2"W x 39 1/2'H Sub Component Item Totai:$ 387.55 Pin Placement:l 3/8"Setback;Horizontai venc set: Sub Component Item Quantity Totel:$ 387.55 20";Vent Height:One HaM;Exterior Fnish:White; Interiw Finish:White;Glazing:Dual Glazed(Insulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:Clear;Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen:Standard wfth Fiberglass mesh;Breather Tubes:Yas;Clear Opening W:37 1/4"H:12"SQ:3.10 CPD: MIL-A-234-01974-00001 Quote ID: 613 5 Ot B 06/79/2014 Sub Component Item: p RO Size=42"W x 40"H Net Size=41 1/2•W x 39 1/2"H Sub Component item Total:$ 387.55 Fin Placement:1 3!8•Setback;Horizontai vent set: Sub Component Item Quantity Total:$ 387.55 20";Vent Height:One Half;Exterior Finish:White; Interior Finish:Whfte;Glazing:Oual Glazed(Insulated Glass);Outer Glass Lite Optfon:SunCoatMRX;Inner Giass Lite Option:Clear;Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W:37 1/4"H:12"SQ:3.10 CPD: M IL•A-234-0197400001 ManWacturer: Milgard Item: 0014 Locatlon: SOUTH UNIT EAST WALL DINING Quantity: 1 Tuscany,8225T,DDH, RO 52"x 40" UF:0.33,SG�:021,VLT:0.48 619.28 3/32"SunCoatMAX and 3/32"Clear 13.81 Foam Spacer 63.60 Item Total: $ 696.69 X X Fin Placement:1 3/8"Setback;Horizontal Vent Set:20";Vent Height: Item Quantity Total: $ 696.69 One Half;Exterior Finish:White;Interior Finish:White;Glazing:Dual Giazed(Insulated Giass);Outer Giass Lite Option:SunCoatMAX;Inner X v Glass Lite Option:Clear;Glass Thick 1:3/32";Glass Thick 2:3/32"; �� Spacer Type:Foam;Screen:Standard with F' ass mesh;Breather C �� Tubes:Yes;Clear Opening W:21 1/4"H:12" Q:1. CPD: MIL-A-234-01974-00001 --- Line Item Comments: Customer ApprovaL• __ Initials Manufacturer: Milgard Item: 0015 Locatlon: SOUTH UNIT UPPER BEDROOMS Quantity: 2 Tuscany,8120T,HV,RO 52"x 40" UF:0.32,SGC:0.21,VLT:0.49 284.99 3/32"SunCoatMAX and 3/32"Clear 13.81 Foam Spacer 45.85 Item Total: $ 344.65 Fin Piacement:1 3/8"Setback;Sliding Direction:XO;Exterior Finish: Item�uantity Total: $ 689.30 X White;Interior Finish:White;Glazing:Dual Glazed(Insulated Giass); Outer Glass Lite Option:SunCoatMAX;Inner Giass Lite Option:Clear; Glass Thick 1:3/32";Glass Thick 2:3/32";Spacer Type:Foam;Screen: Standard with Fiber sh;Breather Tubes:Yes;Clear Opening W: 23 3/16"H:36 1/2 :5.88 PD:MIL-A-224-03149-00001 � L� Line Item Comments: Customer Approval: Initials Duote ID: 613 6 Oi 8 08/19/2014 Manufacturer: Milgard Item: 0016 Locatlon: SOUTH UNIT UPPER BATHROOM Quantlty: 1 Tuscany,8120T,HV,RO 52"x 40" UF:0.32,SGC:0.21,VLT:0.49 284.99 1/8"SunCoatMAX Tempered and 1/8"P516(Standard Obscure)Tempered 210.04 Foam Spacer 45.85 Item Total: $ 540.88 Fin Placement:1 3/8"Setback;Sliding Direc[ion:XO;Exterior Finish: Item Quantity Total: $ 540.88 X White;Interior Finish:White;Glazing:Dual Glazed(Insulated Glass); Tempered:All;Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:P516(Standard Obscure);Glass Thick 1:1/8";Glass Thick 2: 1/8";Spacer Type:Foam;Screen:Standard with Fiberglass mesh; Breather Tubes:Yes;Clear Opening W:23 3/16"H:36 1/2"SQ:5.88 C�1 STC:30 CPD:MIL-A-224-03151-00001 1 Line Item Comments: Customer Approval: Initiats Manufacturer: Miigard Item: 0017 Location: SOUTH UNIT LOFT Quantlty: 2 Tuscany,8225T,DH,RO 24"x 36" UF:0.33,SGC:021,VLT:0.48 249.49 3/32"SunCoatMAX and 3/32"Ciear 5.92 Foam Spacer 29.09 Item Total: $ 284.50 X Fin Placement:1 3/8"Seffiack;Horizontal Vent Set:18";Vent Height: Item Quantity Total: $ 569.00 One Half;Exterior Finish:White;interior Finish:White;Giazing:Dual Glazed(Insulated Glass);Outer Glass Lite Option:SunCoatMAX;Inner Glass Lite Option:Clear;Glass Thidc 1:3/32";Giass Thick 2:3/32"; X Spacer Type:Foam;Screen:Standard with Fiberglass mesh;Breather Tubes:Yes;Clear Opening W:19 1/4"H:10"SQ:1.34 CPD: M I L-A-234-01974-00001 C 1`� Line Item Comments: Customer Approval: _ _ Initials Other Charges: SUBMITTED BY: SUB TOTAL(taxable):$ 11354.66 SUB TOTAL(non-ta�cable):$ 0.00 ACCEPTED BY: TAXES( 4.400 %):$ 499.61 DATE: __ GRAND TOTAL:$ 11854.27 Notice(If any): For warranty Information please vis(t www.mllgard.com/care-and-warranty! Please note that aclual NFRC energy values may vary from those reported In CTB quote due to varlatlons that may occur during the manufacturing process. In most cases variatlons will be minimal. Please contact your Mligard Iocation with questlons or concerns regarding this potentlal varlatlon. Handing is viewed from outside looking in"X"1�dlcates operable panel."O"indicates flxed panel. 21 items. Quote ID: 613 7 Of 8 O6/79/2014 ADDITIONAL INFORMATION: This Quote fs valid for 30 days.This Is an estimate only and does not include delivery charges. 1 understand that this order will be placed accordfng to these speciflcatlons and is non-refundable. Quote ID: 613 a o} a osnsi2oia � � � � �t�{- d� s- � K■ ■�� ■ CONSULTANTS, INC. P.O. Bpx 4572 . 970-949-9391 � VAIL, COLORAD❑ B 7 658 � . FAX 949-1 577 F/ELD REPORT ro: i DATE.• 4I112015 CRC Design & Remodel ARR/VE: 10:00 am � PA. Box 273 . _. _--. . _.._ _ _ _ _-_ __. __---DEPART.. ___10:30am _- -._ _ _ Vail, CO 81658 WEATHER.• Sunny ' ATTENTlOAI: i I Matt Bomer ' JOB NUMBER: 1408-17 , PROJECT.• 1767 Alpine Drive Remodei � PRESENTATSlTE.� Ryan Schmidt,Jeremy Schinn STATUS OF COMPLET/ON: Partiai � Isolated Footing Rebar Observation � Observation of rebar piacement at the two (2) isolated footings was performed on 4/112015 prior to concrete pour as requested by CRC Design & Remodel. Footing dimensions and rebar placement were observed to be consistent with the Foundation Plan and datails indicated on structural plan S1. This report is limited to the observed rebar locations for the referenced building prior to placement of concrete. Please contact KRM Consultants with any questions. S/GNED• COPY TO: I �r ? Ry . Schmidt REV/EWED: ; Tim D. Hennum, PE � � o�PpO �tE��slF �sssaoe n I Q����p HE/y�Y�°JF , c,..�,� G� o � i �`�lf i�! e ��fl • s i A e,��-, . �•� D^ e �,, - ^ �� •es��° C\.` F��y����,�,� F�� � APR�._0 �, 2015