08-04-2014 Inspection -uest Reporting Page 12
4:09 pm — Vail, CO ity Of ircrat4' 03Thb
Requested Inspect Date: Tuesday August 05 2014
Site Address: 2605 BALD MOUNTAIN RD VAIL
Flat portion of roof
A/P/D Information
Activity OTC14-0037 Type: OTC Sub Type: ADUP Status: ISSUED
Const Type Occupancy: Use: lnsp Area:
Owner ROGERS, BRUCE A.
Contractor: CRW INC Phone: 720-348-0438
Description: Install new.060 mil EPDM roof system-Flat roof only
Requested Inspection(s)
Item• 542 PLAN-FINAL Requested Time: 08:00 AM
Requestor Phone:
Comments 720-301-2776
Assigned To GRUTHER Entered By: MHAEBERLE K
Action Time Exp:
Item. 90 BLDG-Final Requested Time: 02:30 PM
Requestor Phone:
Comments 720-301-2776
Assigned To SGR ER Entered By: MHAEBERLE K
Action la C.!d Time Exp:
Inspection History
Item: 542 PLAN-FINAL
Item: 90 BLDG-Final
4
4
I
I
REPT131 Run Id: 14726
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
7000F OE
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
OVER THE COUNTER PERMIT
OVER THE COUNTER Permit #: OTC14 -0037
Project #: PRJ14 -0378
Job Address: 2605 BALD MOUNTAIN RD VAIL
Applied.....: 07/30/2014
Location......: Flat portion of roof
Issued...: 07/30/2014
Parcel No....: 210103401030
Valuation.....: $36,489.00
OWNER ROGERS, BRUCE A. 07/30/2014
441 PIERMONT AVE
PIERMONT, NY
10968
APPLICANT CRW INC 07/30/2014 Phone: 720 - 348 -0438
PETER HOLT
2310 S RARITAN STREET
ENGLEWOOD
CO 80110
License: C000003986
CONTRACTOR CRW INC 07/30/2014 Phone: 720 - 348 -0438
PETER HOLT
2310 S RARITAN STREET
ENGLEWOOD
CO 80110
License: C000003986
Description:
Install new .060 mil EPDM roof system - Flat roof only
.................................................. ............................... FEE SUMMARY ...,,............_._................................................
...........
Building Permit ------ - - - - -> $512.45 Bldg Plan Check ----- - - - - -> $333.09
Use Tax Fee------------------ - - - - ->
$529.78
Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00
Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00
Additional Fees--------------- - - - - ->
$20.00
Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00
Investigation------------------ - - - - ->
$0.00
will call ------------------------------ >
$5.00
TOTAL PERMIT FEES--------- - - - - ->
$1,400.32
Payments ------------------------------- >
$1,400.32
.................
BALANCE DUE ------------------------ >
$0.00
DECLARATIONS
agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM.
combination permit-012811
rwwx xwxw wxxrrxwrrr* x* r** wwwwwwwxxwxxxxxxxxxrx* xr* w*ww wrww** wr+ xxxx xxxxrxr*** w*** r*w*x***wxwxx xxx+ xxxx* r* rwwwxwwwxxxxx* xxxr x*w wwwxwxrwwxx** xx*r rrxrrwwxwxxtwrrrrrrrrrxwrrxxwxwxxttxwxr
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit #: OTC14 -0037 Address: 2605 BALD MOUNTAIN RD VAIL
Owner: ROGERS, BRUCE A. Location: Flat
portion of roof
w: xrxrxxxrrrrwwwwrxwww xrxwxxxxxr** wrwrwwwwxw* wxx* xxx***r r'*w*w*w wwwwwwwxxxwwxxx* x******+ wwww xwx rxwrx***** rrww+ wwwxwrwxxxxxx****w r* wwxwwwrrr* xrx* rrrrw*w wxwwwxwxwwxrxxxxrrrrrrxrrrrxwwr
Cond: 8
(PLAN): No changes to these plans may be made without the
written consent of Town of Vail staff and /or the
appropriate review committee(s).
Cond: 201
(PLAN): DRB approval shall not become valid for 20 days
following the date of approval, pursuant to the Vail Town
Code, Chapter 12 -3 -3: APPEALS.
Cond: 202
(PLAN): Approval of this project shall lapse and become
void one (1) year following the date of final approval,
unless a building permit is issued and construction is
commenced and is diligently pursued toward completion.
combination permit-012811
TOWN OF V)UL �7
Permit #: OTC14 -0037
Owner: ROGERS, BRUCE A.
portion of roof
REQUIRED INSPECTIONS AND STATUSES
Address: 2605 BALD MOUNTAIN RD VAIL
Location: Flat
Item: 00542 PLAN -FINAL
Item: 00090 BLDG -Final
combination permit_012811
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number: R140001105 Amount: $1,400.32 07/30/201402:34 PM
Payment Method: Check Init: SAB
Notation: 9352 CRW
-----------------------------------------------------------------------------
Permit No: OTC14 -0037 Type: OVER THE COUNTER
Parcel No: 2101 - 034 - 0103 -0
Site Address: 2605 BALD MOUNTAIN RD VAIL
Location: Flat portion of roof
Total Fees: $1,400.32
This Payment: $1,400.32 Total ALL Pmts: $1,400.32
Balance: $0.00
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code
-------------- - - - - --
Description
------------------------
Current Pmts
BP
00100003111100
- - - - --
BUILDING PERMIT FEES
------ - - - - --
512.45
DR
00100003112200
DESIGN REVIEW FEES
20.00
PF
00100003112300
PLAN CHECK FEES
333.09
UT
11000003106000
USE TAX 4%
529.78
WC
00100003112800
WILL CALL INSPECTION FEE
5.00
It fib-- C 0
Community Development flepartment
75 South Frontage Road West
LO TOWN Of VAIL Vail, CO 811157
community Development Tel: 970 -079 -2128
Department www.vailgov.com
Development Review Coordinator
4* RE -ROOF PERMIT APPLICATION
(This permit is applicable to one and two family dwelling units, multifamily buildings)
(Permit fee = standard building fees and design review fee)
Q
0
i
N
I
0
Project anon
Ow �C S
Owner Name:
Parcel#: 02101-05`4-01-030-
{For Parcel S, contact Eagle County Assessors Office at (970.326.8640 o, visit
www.0agle-county.us.1pallel
Project Street Address:
2605 aaAl rte i��
(Number) (Street)
Contractor Information
Business Name: C? tO 1 A( -
(Suite #)
Business Address: 2-6 10 S. , '`1` 6crX S t-
City�Y1:1.-- 1y0C)�` State: Cc Zip: LIn
Contact Name:
_Ce
Contact Phone: x-20 V
Type of Building:
Multiramily (EJ) One Family (F-5) Two Fatuity (Duplex)
&aint Property Owner Written Approval Letter (duplex or
mulli-family HOA)
Two (2) plan sets indicating:
• Site plan showing location of balconies, decks, slair-
ways, sidewalks, pedestrian and vehicular exits from
the building and utility meters
• Roof plan showing pitch and slope
• Snow retention method and location. Multi- family
building snow retention is required to be designed,
signed and sealed by a lioensed engineer
If heat tape is to be used as snow retention, load cal-
culations must be provided
• Material type (I.e. Composite Shingles Class A) and
color
Full
l�%7) • Fu11 view roof photos of the entire building
• Note: Roofs with a horizontal dimension less than 48'
are exempted from snow relenton
Contact E -Mail:
Applicant Information (fill in if different from contractor) Detailed Scope and Location of Work; llS)st.1 / IkId S
Applicant Name:
Applicant Phone:
' Applicant E -Mail:
I hereby acknowledge that I have read this application, filled out
in full the information required, completed an accurate plot plan,
and stale that all the information as required is correct. I agree to
comply with the information and plot plan, to comply with all Town
ordinances and state laws, and to build this slrucdure according to
the town's zoning and subdivision codes, design review ap-
proved, International Building and Residential Codes and other
rdinances fie Town applicabre thereto.
Owner7OWer's Representative Signalure Required (typed or digital
signature)
Checking this box indicates yov are electronically signing
this application and agree to the above statement.
.o o In r-00 ± 5; 11 t.
(use additional sheet if necessary)
Valuation of
Work Included Plans Included Work
Eledricaf (Yes No ((Yes i`)No
Building Yes ((_)No
Varue of all work being performed:
(value based on IBC Sedion 149.3 S IRC SecBm 100.3)
Electrical Square Foolage
Date Received:
For Office Use Only- Project #: / I "[ • () 3) 0
Fee Paid: _ (
RecelJed From: Building Fennit #
Cash Check # - o : `•,
CC: Visa / PAC Last 4 CC 0 Aulh # Lot IIJj:: Blockf a Subdivlslom VY r-IL- l3
13-Jan 18
rowN of va� i�>
JOINT PROPERTY OWNER
WRITTEN APPROVAL LETTER
The applicant must submit written joint property owner approval for applications affecting shared ownership properties
such as duplex, condominium, and multi- tenant buildings. This form, or similar written correspondence, must be com-
pleted by the adjoining duplex unit owner or the authorized agent of the home owner's association in the case of a con-
dominium or multi- tenant building. All completed forms must be submitted with the applicants completed application.
I, (print name)
of property located at ) (, o S— L AL D /'! •• Rfrti
approval of the plans dated
A-13
a joint owner, or authority of the association,
provide this letter as written
which have been submitted to the
Town of Vail Community Development Department for the proposed improvements to be completed at the address not-
ed above. I understand that the proposed improvements include:
c s K r,
I understand that modifications may be made to the plans over the course of the review process to ensure compliance
with the Town's applicable codes and regulations; and that it is the sole responsibility of the applicant to keep the joint
property owner apprised of any changes and ensure that the changes are acceptable and appropriate. Submittal of an
application results in the applicant agreeing to this statement.
Signature
5
Print Name
/ A -/
Date
Town of Vasil 2�
OFFICE
COPY
... ..........
..........
... n
� Vail
E IEWED
FOR Coop
i C 01 ANANCE
D
�—_ ...
i
alcon
,
y g
is 1
f• -
(� ✓ N
Balcony G
(` fi.
0
U)
n
77
East deck
03
Qj
X N
p = 70 _
p
p fl N O' 0 0
o A
7CI n o -u U3 A a 77 c c m
zr
t Q o
Y + S ` (�
� N
�" d
Account
Account: R009619
Location Owner Information
Situs Address 002605 BALD
Owner Name HILL, JAMES R. &
MOUNTAIN RD #W
ALEXANDRA N.
Tax Area SC 103 - VAIL (TOWN) -
In Care Of Name HILL
SC 103
COMPANIES
Parcel Number 2101- 034 -01 -029
Owner Address 8100 E
Legal Summary Subdivision:
MAPLEWOOD AVE STE 220
VAIL VILLAGE FILING 13 Block:
GREENWOOD VILLAGE, CO
2 Lot: 12A WEST UNIT BK -0297
80111 -4806
PG -0137 01 -04 -80
R773489 QCD I 1 -0 1 -0 1
Transfers
Sale Price
$600,00
$475,000
$265,000
$293,200
Images
• Photo
• Sketch
• GIs
Sale Date
09/24/2002
05/30/1997
05101;1984
04/27/1983
Page 1 of 1
Assessment History
Actual (2014) $1,243,440
Primary Taxable $98,970
Tax Area: SC103 Mill Levy: 46.2540
Type Actual Assessed Acres SQFT Units
Improvements $938,000 $74,660 0.000 3310.000 0.000
Land $305,440 $24,310 0.273 0.000 0.000
Reception Number
810379
Book Page
B: 038511:0211
B: 035811: 0973
http: / /property.eaglecounty.us/ assessor / taxweb /account.jsp ?accountNum= R009619 06/25/2014
4M.4"00 VERSIGARD EPDM
Code Approval Guide
Underwriters Laboratories
FM Approvals
January 2013
Versico
P. O. Box 1289, Carlisle, PA 17013 -0925
Phone 800 - 992 -7663
www.Versico.com
VERSIc0
ROOFING SYSTEMS
VERSICO
ROOFING SYSTEMS
CODE APPROVAL GUIDE
January 2013
INTRODUCTION
This Code Approval Guide addresses both general information pertaining to Underwriters Laboratories (UL) and
FM Approvals test criteria as well as specific UL and FM code approvals achieved with Versico's VersiGard
Design "A" Adhered, Design `B" Ballasted and Mechanically- Fastened EPDM Roofing Systems. Various
independent test laboratory results along with national building code approvals are also identified in this guide.
Code approvals available with Versico's VersiFleece®, Hot Mopped, VersiFlexTM and VersiWeld® Roofing
Systems are identified in separately published Code Approval Guides.
Code ratings are categorized by roof system type (Adhered, Ballasted, Mechanically- Fastened) and are separated
into 2 sections; UL Approvals and FM Approvals. Underwriters Laboratories rated roof assemblies are grouped
according to deck type (non - combustible or combustible) and are further categorized by the severity of fire exposure
(Class A, B or Q. FM Approvals assemblies are categorized according to deck type and the specific type of
construction (new, tear -off or retrofit). These ratings can also be found at the FM Approvals web site using
RoofNAV (free subscription) at http: / /roofnay.fmglobal .com/roofnav /login.aspx.
The listed assemblies contained in this guide are grouped generically based on deck classification. Specific
substrate requirements for each Versico Roofing System can be identified in the respective Versico Specifications.
In the UL and FM Approvals throughout this guide, when multiple layers of insulation are referenced, the product
listed first identifies the insulation directly below the membrane. For example; a listing of Recovery
Board/Polyisocyanurate indicates the Recovery Board is installed directly under the membrane. A listing of
Gypsum Board/Polystyrene indicates the Gypsum Board is installed directly under the membrane.
The Table of Contents on the following page identifies the sections contained in this publication.
om.
VERSICO
ROOFING SYSTEMS
Code Approval Guide
January 2013
Table of Contents
Page
General Guidelines for UL and FM Code Compliance ............................................................................ ..............................2
UL and FM Code Approvals:
VersiGardNersiGard White Design "A" Adhered Roofing Systems:
VersiGard Metal Retrofit Roofing Systems:
ULand FM Approvals .................................................................................................................... .............................26
National Building Code & Dade County Florida Approvals
UL Class A Approvals ................................................................................................................ ...............................
ULClass B Approvals ..................................................................................................................... ..............................4
ULClass C Approvals ..................................................................................................................... ..............................4
ULExisting Rating to remain .......................................................................................................... ..............................4
FM 1A -90 Insulation Mechanically Attached ................................................................................ ............................... 5
FM 1A -150 Insulation Mechanically Attached ............................................................................... ..............................5
FM 1A -225 Insulation Mechanically Attached ............................................................................... ..............................5
FM 1A -90 Cover Board Mechanically Attached ............................................................................. ..............................6
FM 1A -465 Insulation or Cover Board /Insulation DASH/FAST Adhesive adhered to Structural Conc ....................... 7
FM 1A -375 OSB Composite DASH/FAST Adhesive adhered to Structural Concrete .................. ............................... 7
FM 1A -90 Insulation Attachment to Poured Gypsum with FAST 100 LV Adhesive (Full Coverage) ......................... 7
FM 1A -465 725 TR with Insulation DASH/FAST Adhesive adhered to Structural Concrete ....... ............................... 8
FM 1A -150 Insulation DASH/FAST Adhesive adhered to Tectum Deck ....................................... ..............................8
FM 1A -90 Base layer of insulation fastened; Top layer of Insulation adhered with DASH/FAST Adhesive ............... 8
FM Ratings with "Extruded" DASH/FAST Adhesive for insulation attachment ........................... ..............................9
FM 1A -300 Hot Asphalt attached Insulation .................................................................................. .............................10
FM 1A -90 Base layer of insulation fastened; Top layer of Insulation adhered with Hot Asphalt .. .............................10
FM Ratings with One Step Insulation adhesive ............................................................................ ............................... l l
FM Ratings with Olybond 500 BA Insulation adhesive ............................................................... ..........................12 -13
FM Ratings for Membranes installed directly on cellular lightweight insulating concrete deck .... .............................13
1 -165 Wind Uplift Equivalency Ratings (Over OSB) .................................................................... .............................14
VersiGard Design "B" Loose Laid Ballasted Roofing Systems:
ULApprovals ............................................................................................................................... ............................... 15
FMCriteria ................................................................................................................................... ............................... 15
VersiGard Design "C" Loose Laid Protected Roofing Systems:
ULApprovals ................................................................................................................................. .............................16
VersiGard Mechanically Fastened Roofing Systems:
ULClass A Approvals .................................................................................................................... .............................17
ULClass B Approvals .................................................................................................................... .............................18
ULClass C Approvals .................................................................................................................... .............................19
ULExisting Rating to remain ......................................................................................................... .............................19
FM Ratings with Mechanically Fastened membrane and Plates ................................................... ............................... 20
FM Ratings with Mechanically Fastened membrane and Bars ....................................................... .............................21
FM Fire Ratings with Mechanically Fastened membranes ............................................................. .............................22
1 -120 Wind Uplift Equivalency Ratings ........................................................................................ .............................23
ANSI -SPRI 4474Approvals with Mechanically Fastened membrane and Plates ........................... .............................24
ANSI -SPRI 4474 Approvals with Mechanically Fastened membrane an
VERSICO VersiGard EPDM Codes — January 2013 Page 1
ROOFING SYSTEMS
dBars ............................ .............................25
VERSICO VersiGard EPDM Codes — January 2013 Page 1
ROOFING SYSTEMS
General Guidelines for
Underwriters Laboratories and FM Approvals
Code Compliance
These guidelines are intended to focus on the essential criteria to be followed when an Underwriters Laboratories (UL) and/or FM Approvals
(FM) approved assembly is specified. Generally, the Versico published specifications reflect the minimum requirements necessary to obtain
the applicable Versico warranty. Code requirements are not specifically covered in the Versico specifications and are considered to be
above and beyond the provisions of the Versico warranty.
Individuals specifying an approved assembly or selecting various products to achieve a specific UL/FM rating must recognize the importance
of ensuring proper component selection to fully comply with the most current listings published. All materials used in the roofing system
must be UL and /or FM approved and must have been tested together as part of a complete roofing assembly.
In addition to the code approval listings in this guide, information pertaining to approved assemblies can also be referenced in the following
directories:
1. Underwriters Laboratories On -Line Certifications Directory (ut:com)
2. FMApprovals Roof/Vav website (roofnay.com). FM RoofNav assembly numbers can be obtained from this website.
Underwriters Laboratories, FM Approvals and ANSI/SPRI WD -1 Clarifications/Enhancements:
A. Underwriters Laboratories
1. The criteria required to obtain UL external fire ratings (Class A, B or C) can be identified in this guide or can be searched for on
the UL website using the UL category code TGFU. UL ratings approved for use on combustible decks are also acceptable on non-
combustible decks.
2. For UL internal fire ratings (hourly constructions - P Numbers), search the UL website using the UL category code BXUV.
B. FM Approvals
Uplift ratings listed in this guide are for the field of the roof. Additional requirements /enhancements are required by FM in the perimeter and
comer areas, for deck securement and for perimeter nailer /edge attachment. Refer to FM Property Loss Prevention Data Sheets 1- 28,1 -29 and
1 -49 for specific requirements. On FM insured projects, the local FM insuring agent MUST review and approve the proposed roofing
assembly prior to installation. When FM is not the insuring entity for the building, use the Approved American National Standard
ANSI/SPRI WD -1 for design purposes
Note: All Versico Roof Systems referenced within this document meet Class 1 construction and Severe Hail (SH) ratings.
C. APPROVED AMERICAN NATIONAL STANDARD ANSI/SPRI WD -1
The ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies should be referenced when a project is not FM insured. This
document was developed as a consensus National Standard and provides a methodology for designing for wind uplift resistances of roofing
system assemblies. Insulation fastening patterns are included in this document. The fastening patterns are approved for use by Versico.
SUMMARY
Due to complexity of the code documents and the variety of information that must be reviewed, it is important to consult with Versico and
other respective manufacturers concerning the most current available approvals.
• Prior to project bid - Products specified by the architect must be thoroughly investigated to determine if the specified rating can be
achieved and local building codes must be consulted regarding any additional requirements.
• Prior to installation - Project managers should review the code requirements with field construction personnel to ensure
compliance with project requirements.
Upon completion of the roofing installation, each project is inspected by a Versico Technical Representative to ensure compliance
with Versico's current specification requirements for the issuance of the applicable warranty. However, this inspection is not for the
purpose of verifying code compliance.
%M0
VERSICO VersiGard EPDM Codes — January 2013 Page 2
ROOFING SYSTEMS
Underwriters Laboratories Approvals
Desien "A" Adhered RoofinE Svstems
* - Maximum slope with Securock is 3" per foot on combustible deck. When used on non- combustible deck, the slope is unlimited.
Notes:
(1) The specified membrane maybe coated with EM -8 Hypalon® Coating in accordance with Versico's Specifications. The deck slope is limited to a 3 -1/2" maximum or
the maximum slope specified for construction without coating, whichever is less.
(2) The specified membrane may be coated with a maximum of two coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal /sq /coat and maintain the slope ofthe
uncoated assembly.
(3) Insulation may be mechanically fastened, attached with DASH/FAST Adhesive, Type III or IV hot asphalt or UL approved cold adhesive.
(4) 7/16" thick non - veneer, APA rated oriented strand board (OSB) may be substituted for Versico Recovery Board in all listed assemblies. The fastening pattern for the
OSB must conform with Versico Detail A -27.4.
(5) Minimum 1/2" thick gypsum board can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot. 1/4" thick Georgia Pacific
DensDeck, Sound Deadening Board (minimum weight of 1.09 pounds per sq. ft.) or 2- layers of Versico FR Base Sheet 1S(max. slope cannot exceed 1/2 ") may be
substituted for 1/2" thick gypsum board beneath the insulation. On Retrofit/No Tear -off projects, where the existing roof is Class A rated, the gypsum board can
be eliminated: Existing roofs that are Class B or C rated require use of gypsum board to achieve a Class A rating, otherwise, the roofing system will retain the existing
UL rating.
(6) Assembly only permitted on non - combustible decks.
(7) Min. Class C rated type III or IV Smooth Asphalt BUR, Modified Bitumen or Mineral Surfaced Cap Sheet to remain.
(8) Insulation joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck.
(9) Combustible Deck ratings can be used on non - combustible decks.
VVIA
VERSIC(D VersiGard EPDM Codes — January 2013 Page 3
ROOFING SYSTEMS
"A"
UL Class
....,.. w
VersiGard
Deck Type
Insulation (3)(4)
(UL Classified)
Insulation
Thickness
Bonding Adhesive
NR FR
.045 ",
060" or
VersiGard
Reinforced
VersiGard
R
Reinforced
VersiGard
White
.060"
.090"
Non - Combustible
Versico Recur cry Board, SecurShield
and Combustible
( For combustible decks,
HD, or SecurShield HD Plus over:
Polyiso
1/2" Min./
Any
G200SA / Low VOC
1"
1"
2 -1/2"
1 -12"
gypsum board must be
installed beneath
insulation listed 5
)O
Insulfoam I or VIII (6)
Aqua Base 120
Versico Polyiso MP -H/ Insulfoam [
or VII
1�� /Any
G200SA / Low VOC
I/2"
1 /�"
314"
L' "
Aqua Base 120
OSB or OSB/Polyiso
7/16 " / Any
G200SA / Low VOC
2 -112"
2 -1/2"
OSB/Insulfoam I or VIII
7/16 " / An
G200SA / Low VOC
1
1
2"
1"
Versico Polyiso MP -H, SecurShield
Any
G200SA /Low VOC
12"
1/2"
3: 3"
12"
Aqua 20
Base 1
Non - Combustible
Existing Roof to remain
None
N/A
G200SA / Low VOC
1/2"
1/2"
1/2"
1/2"
(7)
New Construction:
Approved Cellular
G200SA / Low VOC
Any
1"
4"
1 -1/2"
Concrete, Poured
Structural Concrete
N/A
Pre -Cast Concrete with
Aqua Base 120
V
1"
2 -1/2"
12"
Grouted Joints
Combustible (8)(9)
G200SA / Low VOC
Versico SecurShield
3" Min
1/2"
3!4"
L?"
Aqua Base 120
Versico polyisocyanurate
SecurShield or SecurShield HD
3" Min.
G200SA / Low VOC
Composite
1/2"
1/2"
1/2"
1/2"
Over
1 layer FR Base Sheet IS
1.9" Min. / 1 layer
Aqua Base 120
Versico SecurShield HD EPS
CornComposite
Po
4.5" Min.
G200SA /Low VOC
I/2"
1/2"
1/2"
1/2"
Aqua Base 120
Versico SecurShield HD or HD Plus
Polyisocyanurate
Over
1/2" Min./ 2.5" Min.
1/2" Min. / 1.4"
G200SA /Low VOC
1/2"
1/2"
1/2"
1/2"
1 layer FR Base Sheet IS
Min. / I layer
Aqua Base 120
Versico SecurShield HD or HD Plus /
Insulfoam I or VIII
l/2 " Min / 4" Min.
G200SA / Low VOC
I/2"
I /2"
1/2"
l 2"
Aqua Base 120
Versico SecurShield CD
1" Min.
G200SA / Low VOC
Over
Insulfoam I or VIII
V Min. / 3.5" Min.
1/2"
12"
1/2"
12"
Aqua Base 120
Polyiso listed above over 2- layers
Versico FR Base Sheet IS
Any/
2- layers
G200SA / Low VOC
1/2"
12"
3/4"
12"
Aqua Base 120
Versico Dens -Deck Prime
1/4" Min.
G200SA / Low VOC
An
4"
1 -1/2"
Aqua Base 120
2"
3"
1"
Versico Dens -Deck Prime or
Securock / Polyiso iso
1/4" Min. / Any
G200SA / Low VOC
Any*
4 "*
1 -12"
3"
Aqua Base 120
2"
3"
1"
Versico Dens -Deck Prime or
1/4" Min./
G200SA / Low VOC
Any*
4 "*
1
Aqua Base 120
2"
3"
Securock / Insulfoam I or VIII
An Y
* - Maximum slope with Securock is 3" per foot on combustible deck. When used on non- combustible deck, the slope is unlimited.
Notes:
(1) The specified membrane maybe coated with EM -8 Hypalon® Coating in accordance with Versico's Specifications. The deck slope is limited to a 3 -1/2" maximum or
the maximum slope specified for construction without coating, whichever is less.
(2) The specified membrane may be coated with a maximum of two coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal /sq /coat and maintain the slope ofthe
uncoated assembly.
(3) Insulation may be mechanically fastened, attached with DASH/FAST Adhesive, Type III or IV hot asphalt or UL approved cold adhesive.
(4) 7/16" thick non - veneer, APA rated oriented strand board (OSB) may be substituted for Versico Recovery Board in all listed assemblies. The fastening pattern for the
OSB must conform with Versico Detail A -27.4.
(5) Minimum 1/2" thick gypsum board can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot. 1/4" thick Georgia Pacific
DensDeck, Sound Deadening Board (minimum weight of 1.09 pounds per sq. ft.) or 2- layers of Versico FR Base Sheet 1S(max. slope cannot exceed 1/2 ") may be
substituted for 1/2" thick gypsum board beneath the insulation. On Retrofit/No Tear -off projects, where the existing roof is Class A rated, the gypsum board can
be eliminated: Existing roofs that are Class B or C rated require use of gypsum board to achieve a Class A rating, otherwise, the roofing system will retain the existing
UL rating.
(6) Assembly only permitted on non - combustible decks.
(7) Min. Class C rated type III or IV Smooth Asphalt BUR, Modified Bitumen or Mineral Surfaced Cap Sheet to remain.
(8) Insulation joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck.
(9) Combustible Deck ratings can be used on non - combustible decks.
VVIA
VERSIC(D VersiGard EPDM Codes — January 2013 Page 3
ROOFING SYSTEMS
Underwriters Laboratories Approvals
Design "A" Adhered Roofing Systems
_e..,..
JEF�"-aximumnilopel em rave e
FR
VersiGard
VersiGard
VersiGard
Deck Type
Insulation (3)(4)(5)
Insulation
Bonding
Thickness
Thickness
Adhesive
.045",. 060
Reinforced
Reinforced
White .060"
Combustible - Minimum Class
or .090"
N/A
F12
1/2"
Combustible
Polyiso listed on previous
Any/Base
Modified Bitumen to remain
pageNersico FR Base Sheet IS
Sheet
Versico SecurShield or
SecurShield HD Composite
1.9" Min.
Versico SecurShield HD or HD
Min. 1/2" /
Plus / Polyiso
Min. 1.4"
Versico SecurShield CD /
1" Min. /
Insulfoam I or VIII
Any
Versico Recovery Board,
1/2" Min./
SecurShield HD or SecurShield
1 Min./
G200SA /
1;,,.
1 2"
1/2"
I/2"
HD Plus / Polyiso / Versico FR
Low VOC
Base Sheet
Base Sheet IS
Versico Recovery Board,
1" Min./
SecurShield HD or SecurShield
HD Plus / Versico FR Base
Base Sheet
Sheet 1S
Versico SecurShield
1.9" Min.
Over
1.9" Min. /
SecurShield HD Composite
Maximum Slope/.N embrane "fy pe (1)(2)
FR
VersiGard
VersiGard
Deck Type
Insulation (3)(4)(5)
Insulation Bonding
Thickness Adhesive
.045 „ , .060 „
Reinforced
Reinforced
VersiGard
or .090”
FR
White .060"
Combustible
Versico Recovery Board,
SecurShield HD or SecurShield
1/2" Min.
HD Plus
Versico Recovery Board,
1/2" Min. /
SecurShield HD or SecurShield
Any
G200SA /
HD Plus / Polyiso
Low VOC
Unlimited
Unlimited
Unlimited
Unlimited
1/2" Min. /
Versico / Polyiso
Any
Versico Polyiso MP -H,
Any
SecurShield
Notes:
(1) The specified membrane may be coated with EM -8 Hypalon® Coating in accordance with Versico's Specifications.
(2) The specified membrane may be coated with a maximum of two coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal/sq /coat
and maintain the slope of the uncoated assembly.
(3) Insulation may be mechanically fastened, attached with DASH/FAST Adhesive, Type III or IV hot asphalt or UL approved cold adhesive.
(4) 7/16" thick non - veneer, APA rated oriented strand board (OSB) may be substituted for Versico Recovery Board in all listed assemblies. The
fastening pattern for the OSB must conform to Versico Detail A -27.4
(5) Insulation joints (bottom la er ) are to be staggered a minimum of 6" from joints in the wood deck.
VE RSICO VersiGard EPDM Codes — January 2013 Page 4
ROOFING SYSTEMS
Maximum Slope
Insulation
Bonding
FR .045 ", .060" or
Deck Type Insulation
Thickness
Adhesive
.090" and VersiGard
White Membrane
Combustible - Minimum Class
"C" rated Type III or IV Smooth None
N/A
G200SA / Low VOC
1/2"
Asphalt BUR, Mineral Cap or
Modified Bitumen to remain
VE RSICO VersiGard EPDM Codes — January 2013 Page 4
ROOFING SYSTEMS
Underwriters Laboratories Approvals
Design "B" Loose Laid Ballasted Roofing System (1)(2)
Membrane Type: .045" or .060" thick Non - Reinforced EPDM Membrane
.060" or .075" thick VersiGard Reinforced EPDM Membrane
_,r_ ' (Classified) I Thickness I Slope
Non - Combustible and Combustible I Any UL Classified Insulation Any 2"
New Construction: I None or HP Protective Mat (Refer to Versico I N/A I 2"
Approved Lightweight Insulating Concrete Specifications for requirements)
Notes:
(1) Ballast to be nominal 1 -1/2" diameter, river washed stone at a minimum 10 pounds per square foot. Individual concrete pavers (minimum
18 pounds per square foot) or approved lightweight interlocking pavers (minimum 10 pounds per square foot) may also be used. 1/8"
maximum spacing between pavers is permitted.
(2) Versico HP Protective Mat may be used between the ballast and the membrane without altering the rating.
FM Approvals Research
Calorimeter Tests for the Design "B" Ballasted Roofing System
All constructions listed in the FM Approvals (FM) Approval Guide are Class 1 A, B or C fire rated and minimum Class 60 uplift rated.
Because of the nature of the uplift testing (pressurizing the underside of the deck to minimum 60 pounds per square foot), ballasted
systems cannot be tested. If the ballasted system was tested, it would only require approximately 10 -15 pounds per square foot of uplift
pressure before movement of the stone and membrane would occur. In reality, ballasted systems are capable of resisting much higher
wind forces.
Although ballasted systems are not formally FM approved, FM Approvals conducted research fire tests on Versico's VersiGard Design
"B" Ballasted Roofing System. Two (2) test panels were constructed which consisted of a 22 gauge steel deck, 5/8" thick Type X core
gypsum board, 0.0015" aluminum vapor retarder and 4 -1/4" Versico EPS insulation. The following results were obtained.
Maximum Average Rate of Fuel
Contribution (Btu /Square Feet/Minutes) for various intervals of time
* The fuel contribution rates developed for Test Panel No. 2 were equivalent to Test Panel No. 1
The conclusion of the research report was that the Ballasted System panels had met the fire hazard requirement for Class 1 insulated
steel deck roof construction.
Additionally, FM Approvals has published Loss Prevention Data Sheet 1 -29, Above Deck Roof components that outlines general
guidelines for ballast criteria depending on project conditions (building height, parapet height, location, etc.). According to this
bulletin, FM Approvals' loss experience has been very favorable for single -ply Ballasted Roofing Systems when designed in
accordance with this published criteria.
Although FM does not formally approve Ballasted Systems, job-by-job acceptance can be obtained when FM Approvals is the
insurance underwriter by contacting the local FM office for requirements.
VERSICO VersiGardEPDMCodes — January 2013 Page 15
ROOFING SYSTEMS
3 Minutes
5 Minutes
10 Minutes
Average
FM Class 1 Standard
385
365
340
270
Allowable Deviation
+25
+25
20
+15
Test Panel No. 2 *
124
103
88
31
* The fuel contribution rates developed for Test Panel No. 2 were equivalent to Test Panel No. 1
The conclusion of the research report was that the Ballasted System panels had met the fire hazard requirement for Class 1 insulated
steel deck roof construction.
Additionally, FM Approvals has published Loss Prevention Data Sheet 1 -29, Above Deck Roof components that outlines general
guidelines for ballast criteria depending on project conditions (building height, parapet height, location, etc.). According to this
bulletin, FM Approvals' loss experience has been very favorable for single -ply Ballasted Roofing Systems when designed in
accordance with this published criteria.
Although FM does not formally approve Ballasted Systems, job-by-job acceptance can be obtained when FM Approvals is the
insurance underwriter by contacting the local FM office for requirements.
VERSICO VersiGardEPDMCodes — January 2013 Page 15
ROOFING SYSTEMS
Underwriters Laboratories Approvals
Design "C" Loose Laid Protected Roofing System (1)(2)
Membrane Type: .045" or .060" thick Non - Reinforced EPDM Membrane
.060" or .079' thick VersiGard Reinforced EPDM Membrane
Notes:
(1) Ballast to be nominal 1 -1/2" diameter, river washed stone at a minimum 10 pounds per square foot. Individual concrete pavers
(minimum 18 pounds per square foot) or approved lightweight interlocking pavers (minimum 10 pounds per square foot) may also
be used. 1/8" maximum spacing between pavers is permitted.
(2) Versico HP Protective Mat must be used between the ballast and the extruded polystyrene insulation.
(3) Insulation products listed are for use above the EPDM membrane. One layer of any UL classified insulation may be added below
the membrane without altering the rating.
AM ,.
VERSlCO VersiGard EPDM Codes — January 2013 Page 16
ROOFING SYSTEMS
Underwriters Laboratories Approvals
VersiGard Reinforced Mechanically - Fastened Roofing System
Membrane Type: .045, .060 or .075" inch thick VersiGard Reinforced or VersiGard Reinforced
FR EPDM Membrane (1)(2)
Notes:
(1) The specified membrane may be coated with EM -8 Hypalon Coating in accordance with Versico's Specifications.
(2) The specified membrane may be coated with a maximum of two coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal/sq /coat and
maintain the slope of the uncoated assembly
(3) Minimum 1/2" thick gypsum board can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot. 1/4"
thick Georgia Pacific DensDeck, Sound Deadening Board with a minimum weight of 1.09 pounds per square foot may be substituted for
1/2" thick gypsum board (not for use directly over existing roofing membrane). On RerooVNo Tear -off projects, where the existing roof is
UL Class A rated, the gypsum board may be eliminated. Existing roofs that are Class B or C rated will require the use of gypsum board to
achieve a Class A rating, otherwise, the new roofing system will retain the existing UL rating.
(4) Assembly not permitted on combustible decks, even with gypsum board underneath.
(5) Insulation joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck.
(6) Combustible deck ratings may be used on non - combustible decks.
QWA0
VERSICCG VersiGard EPDM Codes —January 2013 Page 17
ROOFING SYSTEMS
Maximum Slope
VersiGard
VersiGard
Deck Type
Insulation
Insulation
Reinforced
Reinforced
FR
Non - Combustible
Versico Recovery Board, SecurShield HD or
1/2 " -3"
1"
2 -1/2"
And Combustible
SecurShield HD Plus
(For combustible decks,
Versico Recovery Board, SecurShield HD or
gypsum board must be
SecurShield HD Plus/Polyisoc anurate
1/2" Min. /Any
1"
2 -1/2"
installed beneath the
Versico Recovery Board, SecurShield HD or
insulations listed 3
) O
SecurShield HD Plus /Insulfoam I or VIII(4)
1/2" Min. /Any
I"
1"
Versico Polyiso MP -H, SecurShield
Any
1/2"
3/4"
Versico Pol iso MP -H / Insulfoam I or Vlll (4)
l" / Any
1/2"
3/4"
Tenneco PB -6 over min. Class C Type III or IV
Min. 3/8"
N/A
1"
Asphalt BUR or Ca Sheet
New Construction:
Lightweight Insulating
None
N/A
3/4"
41'
Concrete or
Gypsum (Grouted Joints)
Combustible (6)
Versico SecurShield (5)
Over
3" Min.
1
Insulfoam I or VIII
Versico Poly isocyanurate SecurShield or
3" Min.
SecurShield HD Composite
Over
1.9" Min. / I layer
1 layer FR Base Sheet 1S
Versico SecurShield HD or HD Plus / Insulfoam 1
1/2" Min. / 4" Min.
or VIII
Versico SecurShield HD EPS Composite
4.5" Min.
Versico SecurShield HD or HD Plus /
1/2" Min./ 1.4"
Polyisocyanurate
Min.
Over
1/2"
1/2"
1 layer FR Base Sheet 1 S
Min./
Min. layer
Mn. / 1 la er
Versico SecurShield CD
1" Min.
Over
Insulfoam I or VIII
1" Min. / 3.5" Min.
Two layers of Versico FR Base Sheet IS
2 layers
112"
3/4"
Poly isocy anurate listed above over 2- layers FR
Any /2- layers
1/2"
3/4"
Base Sheet 1S
Gypsum Board (3)
1/2" Min.
3"
4"
Gypsum Board/Polyisocyanurate (3)
1/2" Min. /Any
3"
4"
Gypsum Board/Insulfoam I or VIII (3)
1/2" Min. /An
3"
4"
Notes:
(1) The specified membrane may be coated with EM -8 Hypalon Coating in accordance with Versico's Specifications.
(2) The specified membrane may be coated with a maximum of two coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal/sq /coat and
maintain the slope of the uncoated assembly
(3) Minimum 1/2" thick gypsum board can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot. 1/4"
thick Georgia Pacific DensDeck, Sound Deadening Board with a minimum weight of 1.09 pounds per square foot may be substituted for
1/2" thick gypsum board (not for use directly over existing roofing membrane). On RerooVNo Tear -off projects, where the existing roof is
UL Class A rated, the gypsum board may be eliminated. Existing roofs that are Class B or C rated will require the use of gypsum board to
achieve a Class A rating, otherwise, the new roofing system will retain the existing UL rating.
(4) Assembly not permitted on combustible decks, even with gypsum board underneath.
(5) Insulation joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck.
(6) Combustible deck ratings may be used on non - combustible decks.
QWA0
VERSICCG VersiGard EPDM Codes —January 2013 Page 17
ROOFING SYSTEMS
Underwriters Laboratories Approvals
VersiGard Reinforced Mechanically- Fastened Roofing System
Membrane Type: .045 ", .060" or .075" thick VersiGard Reinforced or VersiGard Reinforced FR
EPDM Membrane (1)(2)
Notes:
(1) The specified membrane may be coated with EM -8 Hypalon Coating in accordance with Versico's Specifications.
(2) The specified membrane may be coated with a maximum oftwo coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal /sq /coat and maintain the slope of
the uncoated assembly.
(3) Minimum 1/2" thick gypsum wallboard can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot. 1/4" thick Georgia
Pacific DensDeck or Sound Deadening Board with a minimum weight of 1.09 pounds per square foot may be substituted for 1/2" thick gypsum wallboard (not for
use directly over existing roofing membrane). On Retrofit/No Tear -off projects, where the existing roof is Class B or C rated, the gypsum board may be
eliminated and the new roofing system will retain the existing UL rating or achieve the new system rating, whichever is less (i.e., existing Class B roof is overlaid
with new Class B system - resultant rating will be Class B without the requirement for gypsum board; existing Class C roof is overlaid with new Class B system -
resultant rating will be Class C without the requirement for gypsum board).
(4) Insulation joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck.
V E RSI CCG VersiGard EPDM Codes — January 2013 Page 18
ROOFING SYSTEMS
1Vfaximum`
VersiGard
VersiGard
Deck Type
Insulation
Insulation
(UL Classified)
Reinforced
Reinforced
FR
Combustible
Polyisocyanurate listed on previous pageNersico FR
Any/Base Sheet
1/27'
1/2"
Base Sheet 1S
Versico Polyiso SecurShield or SecurShield HD
1,9" Min.
1/2"
1/2"
Composite
Versico Recovery Board, SecurShield HD or
1/2" Min. /1" Min/
3/4"
V
SecurShield HD Plus/Polyisocyanurate/FR Base Sheet 1S
Base Sheet
Versico Recovery Board, SecurShield HD or
1"/ Base Sheet
3/4"
1"
SecurShield HD Plus/FR Base Sheet 1S
Versico SecurShield (4) Over
1.9" Min.
SecurShield HD Composite
Versico SecurShield CD / Insulfoam I or VIII
V Min. / Any
1/2"
1/2"
1/2" Min. / 1.4"
Versico Securshield HD or HD Plus / Pol iso
Min.
Inverted G3 Cap Sheet
Base Sheet
Non - Combustible and
Combustible
New wood deck
construction or over
Versico SecurShield
1.9" Min.
1/2"
1/2"
minimum Class `B"
smooth surfaced BUR
Maximum Slope
Insulation
Insulation
Deck Type
(UL Classified)
Thickness
VersiGard
VersiGard
Reinforced
Reinforced FR
Non - Combustible and
Combustible
Versico Recovery Board, SecurShield
(For combustible decks, gypsum
HD or SecurShield HD Plus
1/2 " -3"
N/A
4"
board must be installed beneath
the insulations listed) (3)
Versico Recovery Board, SecurShield
HD or SecurShield HD Plus/
1/2" Min. /Any
N/A
4"
Poly isocyanurate
New Construction:
Lightweight Insulating Concrete
None
N/A
N/A
4"
and Gypsum (grouted joints)
Gypsum Board
1/2"
N/A
4"
Combustible
Gypsum Board/Polyisocyanurate
1/2" /Any
N/A
4"
Notes:
(1) The specified membrane may be coated with EM -8 Hypalon Coating in accordance with Versico's Specifications.
(2) The specified membrane may be coated with a maximum oftwo coats of Versico Acrylic Coating applied at the rate of 1 -1/2 gal /sq /coat and maintain the slope of
the uncoated assembly.
(3) Minimum 1/2" thick gypsum wallboard can be a classified or unclassified material with a minimum weight of 1.84 pounds per square foot. 1/4" thick Georgia
Pacific DensDeck or Sound Deadening Board with a minimum weight of 1.09 pounds per square foot may be substituted for 1/2" thick gypsum wallboard (not for
use directly over existing roofing membrane). On Retrofit/No Tear -off projects, where the existing roof is Class B or C rated, the gypsum board may be
eliminated and the new roofing system will retain the existing UL rating or achieve the new system rating, whichever is less (i.e., existing Class B roof is overlaid
with new Class B system - resultant rating will be Class B without the requirement for gypsum board; existing Class C roof is overlaid with new Class B system -
resultant rating will be Class C without the requirement for gypsum board).
(4) Insulation joints (bottom layer) must be staggered a minimum of 6 inches from joints in wood deck.
V E RSI CCG VersiGard EPDM Codes — January 2013 Page 18
ROOFING SYSTEMS
VersiGard Reinforced Mechanically- Fastened Roofing Systems
1 -120 (120 psf) Wind Uplift Equivalency Ratings*
Wind uplift testing has been completed in accordance with the FM Approvals 4470 Test Procedure which was witnessed and certified
by Architectural Testing, Incorporated, an industry recognized Independent Testing Laboratory. Over a 22 gauge steel roof deck, the
following results were obtained. (Performance Test Report is on file and available from Versico.)
Membrane Requirements:
Maximum 7 foot wide VersiGard Reinforced .060" thick EPDM membrane with Versico HPV Fasteners and 2" diameter
Polymer Seam Plates spaced 6" on center. *
120 psf Uplift Resistance's (1 -120 Approval Equivalency on 12'X 24' Table) (1)
Insulation
7Any
Minimum Thickness
Insulation Fastening Density
a�pproved insulation
Minimum Approved Thickness (2)
1 per 8 square feet
Notes:
1. Testing conducted on minimum 22 gauge steel roof deck secured to the structural steel supports having a maximum span of 6' on
center. The deck is fastened to the minimum 1/4" thick steel supports with ITW Buildex Traxx/5 fasteners spaced a maximum of
6" on center. Deck side laps are secured with Traxx/1 Fasteners spaced a maximum of 30" on center.
2. 1/2" thick Recovery Board cannot be installed as a single layer directly over wide rib (type B) or intermediate rib (type F) steel
decks. For flute spanability criteria with Polyisocyanurate insulation, contact the respective insulation manufacturer.
A formal FM Approvals (FM) Class 1 -120 rating is available using 10 -foot wide VersiGard
Reinforced .075" EPDM membrane and HPV Fasteners/Polymer Plates. In addition, formal FM 1-
120,1 -135 and 1 -150 ratings are available when Sure -Tite Fasteners /ST Fastening Bars are used for
membrane securement. Refer to page 21 for requirements.
i..I
VERSK: CQ VersiGard EPDM Codes — January 2013 Page 23
ROOFING SYSTEMS
ANSI -SPRI 4474 Approvals
VersiGard Reinforced Mechanically- Fastened Roofing System
Membrane Type: .045",.060" or .075" Thick VersiGard Reinforced or VersiGard Reinforced
FR EPDM Membrane
Approved Deck
Field Sheet
Max. Fastener
Required
Versico Fastener
Uplift
Type
Width
Spacing
Fastening Plates
HPV Fasteners (wood);
Wood or Structural
10'
6" o.c.
Seam Fastening
Concrete
Plates
CD -10 or MP 14 -10
(concrete)
1 -60
HPV Fasteners (wood);
Grade E Steel or
Structural Concrete
8
12" o.c.
Polymer
CD -10 or MP 14 -10
(concrete
HPV Fasteners
Steel (min. 22
(steeUwood);
gauge), Wood or
10'
6" o.c.
Polymer
1 -90
Structural Concrete
CD -10 or MP 14 -10
(concrete)
HPV Fasteners (steel);
Grade E Steel or
Structural Concrete
10'
6" o.c.
Polymer
CD -10 or MP 14 -10
1 -105
(concrete)
10'
Steel (min. 22
6" o.c.
Polymer
HPV Fastener
1 -105
VersiGard
gauge)
Reinforced
.075" only
HPV Fasteners
Steel (min. 22
(steel/wood);
gauge) or Structural
8'
6" o.c.
Polymer
1 -105
Concrete
CD -10 or MP 14 -10
(concrete)
10'
6" o.c.
HPV Fasteners (steel);
1 -120
Grade E Steel or
Polymer
CD -10 or MP 14 -10
VersiGard
Structural Concrete
Reinforced
12" o.c.
1 -60
.075" only
(concrete)
2 -3/8" HPV -XL
Steel (min. 22
10'
12" o.c.
Polymer Seam
HPV -XL Fastener
1 -75
gauge)
Plate
10'
2 -3/8" HPV -XL
Grade E Steel
VersiGard
12" o.c.
Polymer Seam
HPV -XL Fastener
1 -90
Reinforced
Plate
.060" or .075"
only
Notes:
(1) Refer to the following pages for insulation requirements, maximum roof slopes and acceptable roof construction types (new, Tear -off or
retrofit).
VERSICO VersiGard EPDM Codes — January 2013 Page 24
ROOFING SYSTEMS
ANSI -SPRI 4474 Approvals
VersiGard Reinforced Mechanically- Fastened Roofing System
Membrane Type: .045",.060" or .079' Thick VersiGard Reinforced or VersiGard Reinforced
FR EPDM Membrane
Notes:
(1) Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types
(new, Tear -off or retrofit).
W1 ,,
VERSICO VersiGard EPDM Codes — January 2013 Page 25
ROOFING SYSTEMS
Uplift Rating (1)
Grade E
Steel (Min.22
Approved Deck Type
Field Sheet
Max. Fastener
Versico Fastener With
ST Fastening Bars
Deck Type
Width
Spacing
Steel Decks or
Structural Concrete
gauge) Decks
\N ith Polymer Batten or
10'
12" o.c.
1 -90
1 -60
Metal Fastening Bars
10'
6" o.c.
1 -120
1 -105
Steel (type noted) or
Sure -Tite Fasteners (steel
Structural Concrete
10'
6" o.c.
1 -90
1 -90
decks); CD -10 or MP 14-
8'
12" o.c.
1 -105
1 -90
10 (Concrete Decks)
8'
6" o.c.
1 -120
1 -120
1 -120
decks); CD -10 or MP 14 -10
(Concrete Decks)
Sure -Tite Fasteners
Steel (18 gauge) or
10'
12"
1 -90
(Steel Decks)
Structural Concrete
CD -10 or MP 14 -10
(Concrete Decks)
Notes:
(1) Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types
(new, Tear -off or retrofit).
W1 ,,
VERSICO VersiGard EPDM Codes — January 2013 Page 25
ROOFING SYSTEMS
Uplift Rating
Grade E
Approved
Field Sheet
Max. Fastener
Versico HP -X Fastener
Deck Type
Width
Spacing
Steel Decks or
Steel (Min.22 gauge)
\N ith Polymer Batten or
Structural
Decks
Metal Fastening Bars
Concrete
10'
6" o.c.
1 -90
1 -90
Steel (type noted) or
HP -X Fasteners (steel
Structural Concrete
8'
6" o.c.
1 -120
1 -120
decks); CD -10 or MP 14 -10
(Concrete Decks)
8'
12" o.c.
1 -60
1 -60
Notes:
(1) Refer to the following pages for insulation requirements, maximum roof slopes, approved insulation and acceptable roof construction types
(new, Tear -off or retrofit).
W1 ,,
VERSICO VersiGard EPDM Codes — January 2013 Page 25
ROOFING SYSTEMS
VERSIGARD METAL RETROFIT
ROOFING SYSTEM
UNDERWRITERS LABORATORIES (UL) APPROVALS
The UL ratings achieved with the Metal Retrofit Roofing System are identical to the approvals listed for the
VersiGard Reinforced Mechanically- Fastened Roofing System over non - combustible decks depending on the
membrane selected (Standard Reinforced or FR Reinforced EPDM). These ratings are listed on pages 17 -19.
FM APPROVALS
As referenced in FM Approvals Loss Prevention Data Sheet 1 -31, the method of recovering an existing metal
roof system with a single -ply mechanically fastened roofing system where the membrane is secured through the
existing metal roof directly to the structural purlins is recognized as an appropriate recovery system when
installed per the recommendations of FM.
FM Approvals has accepted the securement of Versico's reinforced EPDM membrane with RTS (Reinforced
Termination Strip) as an alternate to "in -seam fastening" as used in our VersiGard Reinforced Mechanically -
Fastened Roofing System. As such, the wind uplift resistance of the VersiGard Metal Retrofit Roofing System
will be equivalent to an FM 1 -90 system when structural purlins are spaced a maximum of 6 -1/2' on center and
the RTS is secured with Versico HPV or Purlin Fasteners and Polymer Seam Plates a maximum of 6" on center
into the purlins. For FM Class 60 wind uplift equivalency, the purlins could be spaced a maximum of 6 -1/2' on
center with the RTS secured with Versico Fasteners and 2" diameter Polymer Seam Plates spaced a maximum of
12" on center into the purlins.
As a standard FM Approvals requirement, additional membrane and insulation securement is necessary in
the corner and /or perimeter areas as outlined in FM Loss Prevention Data Sheets 1 -28, 1 -29 and 1 -31. These
bulletins should be reviewed in their entirety for specific requirements concerning insulation types,
fastening enhancements and other items that may be necessary.
VERSICO VersiGard EPDM Codes — January 2013 Page 26
ROOFING SYSTEMS
NATIONAL, STATE & CITY BUILDING CODE APPROVALS
Authority
Approval
Approved Systems
Cementitious Wood Fiber
Report ESR -1184
"B"
ICC - International Code Council
06- 0403.03
6/28/2011
Gypsum
Report ESR -1463
"A" and "W"
SBCCI
06- 0403.04
"B"
BOCA
"B"
6/28/2011
These Code Bodies merged to
form ICC as of March 2003
06- 0403.01
6/28/2011
"B"
NES — National Evaluation Service, Inc.
Refer to ICC approval
"A" and "MF"
«B„
1CB0
"A" and "W"
Metropolitan Dade County, Florida Building Code Compliance
Product Control Notice of Acceptance
Deck Type
Acceptance No.
Expires
Cementitious Wood Fiber
06- 0331.03
6/28/2011
Concrete
06- 0403.03
6/28/2011
Gypsum
06- 0403.02
6/28/2011
Lightweight Concrete
06- 0403.04
6/28/2011
Steel
06- 0403.05
6/28/2011
Wood
06- 0403.01
6/28/2011
Recover
06- 0331.02
6/28/2011
Versico, a division of Carlisle Construction Materials Incorporated, P. O. Boa 1289, Carlisle, PA 17013
(800)4SYNTEC (800- 479 -6832)
Versico and VersiGard, are Trademarks Versico
Foamular and DuraPink are Trademarks of U. C. Industries, Inc.
Hypalon is a Trademark of E. I. du Pont de Nemours & Company, Inc.
DensDeck is a Trademark of Georgia - Pacific
Styrofoam is a Trademark of Dow Chemical Company
The contents of this issue represent the applicable information available at the time of publication. The contents of older issues are no longer accurate due to
subsequent changes.
2013 Copyright Carlisle Construction Materials Incorporated
VERSICO VersiGard EPDM Codes — January 2013 Page 27
ROOFING SYSTEMS