HomeMy WebLinkAboutB14-0331 cut sheets _
�� Owner's Manual
H E AT G L O� -�������:�"� _ .
2���'' -�=��` _>�-�- ��' Installation and Operation
�;;' � //-�
No one builds a better fire -�-a...:�;_:____, ;!�j
-...- �_ �;
_,._ ;/
Models: �� � GAS-FIRED
- �;;,
COSMO-130-C � •�%i�� U
COSMO-135-C L' o � U$
LISTED
����
�. .
• NOTICE �S��O
DO NOT DISCARD THIS MANUAL C,q 1'
� • Important operating • Read,understand and follow • Leave this manual with �Q
and maintenance theseinstructionsforsafe partyresponsibleforuse
instructions included. instailation and operation. and operation.
A WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death. HOT GLASS WILL
CAUSE BURNS.
• DO NOT store or use gasoline or other flam- ���< DO NOT TOUCH GLASS
mable va ors and li uids in the vicini of this ���'
p q tY ���� UNTIL COOLED.
or any other appliance. NEVER ALLOW CHILDREN
• What to do if you smell gas TO TOUCH GLASS.
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO A barrier designed to reduce the risk of burns
NOT use any phone in your building. from the hot viewing glass is provided with this
- Immediately call your gas supplier from a appliance and shall be installed.
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call This appliance may be installed as an OEM
the fire department. installation in manufactured home (USA
• Installation and service must be performed only) or mobile home and must be installed
by a qualified installer, service agency, orthe in accordance with the manufacturer's
gas supplier. instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
In the Commonwealth of Massachusetts installation must be Standard for Installation in Mobile Homes,
performed by a licensed plumber or gas fitter. CAN/CSA Z24O MH SeC72S, in Canada.
A CO detector shall be installed in the room where the appliance This a liance is onl for use with the t @ S
in installed. pp Y Yp � )
of gas indicated on the rating plate. This
Installation and service of this appliance should be appliance is not convertible for use with other
or *�,� performed by qualified personnel. Hearth & Home
1��6 Technologies suggests NFI certified orfactory trained gases, unless a certified kit is used.
•NS,� professionals, or technicians supervised by an NFI Pour demander un exemplaire en fran�ais de ce Manuel
certified professional.
du propri�taire,visitez www.heatnglo.com/translations.
� Heat&Glo • Cosmo-130-C,Cosmo-135-C • 2239-901 Rev.o • 6/14 1
r r-0►�3
�✓
Installation Manual
Installation and Appliance Setup
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Q WARNING: If the information in these
H EAT�G LO instructions is not followed exactly, a fire
No one builds a better fire or explosion may result causing property
damage, personal injury, or death.
Models: • DO NOT store or use gasoline or other flam-
RED40-NNN GAS-FIRED mable vapors and liquids in the vicinity of this
RED40-NM or any other appliance.
C o�� U$ • What to do if you smell gas
RED40-LM ��STED - DO NOT try to light any appliance.
RE�4�ST NN� - DO NOT touch any electrical switch. DO
NOT use any phone in your building.
RED40ST-NM �� - Immediately call your gas supplier from a
��-�'`` neighbor's phone. Follow the gas suppli-
RED40ST-LM�� ;-��, er's instructions.
�,,���j� � - If you cannot reach your gas supplier, call
' � the fire department.
� ;' • Installation and service must be performed
���. � ,� - � by a qua li fie d ins ta l ler, service agency, or t he
%. �'
� � gas supplier.
�
I '
�� %'
, i' �
iI
�, ;
.��
� .
� HOT GLASS WILL
�; CAUSE BURNS.
This appliance may be installed as an OEM ".= DO NOT TOUCH GLASS
y���,�a�
installation in manufactured home (USA UNTIL COOLED.
only) or mobile home and must be installed NEVER ALLOW CHILDREN
in accordance with the manufacturer's TO TOUCH GLASS.
instructions and the Manufactured Home
Construction and Safety Standard, Title 24 A barrier designed to reduce the risk of burns
CFR, Part 3280 in the United States, or the from the hot viewing glass is provided with this
Standard for Installation in Mobile Homes, appliance and shall be installed.
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s) In the Commonwealth of Massachusetts installation must be
of gas indicated OCl the rating plate. This performed by a licensed plumber or gas fitter.
appliance is not convertible for use with other SeeTableofContentsforlocationofadditionalCommonwealth
gases, unleSS a Certlfied kit IS uSed. of Massachusetts requirements.
Heat�Glo • RED40-NNN,RED40-NM,RED40-LM,RED40-NNN,RED40ST-LM,RED40ST-NM Installation Manual • 2155-975 Rev.D • 4l14 �
1 Listing and Code Approvals
A. Appliance Certification D. High Altitude Installations
NOTICE:Ifthe heating value ofthe gas has been reduced,
MODELS: COSMO-130-C,COSMO-135-C these rules do not apply. Check with your loca!gas utility
LABORATORY: Underwriters Laboratories,Inc.(UL) or authorities having jurisdiction.
TYPE: Direct Vent Heater When installing above 2000 feet elevation:
STANDARD:ANSI Z21.88-2009 CSA 2.33-2009 • In the USA: Reduce input rate 4% for each 1000 feet
Vented Gas Fireplace Heaters above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
This product is listed to ANSI standards for "Vented Gas between 2000 feet and 4500 feet. Above 4500 feet,
Fireplace Heaters" and applicable sections of"Gas Burn- consult local gas utility.
ing Heating Appliances for Manufactured Homes and Check with your local gas utility to determine proper
Recreational Vehicles", and "Gas Fired Appliances for orifice size.
Use at High Altitudes".
Heat & Glo gas inserts are designed for installations into E. Non-Combustible Materials Specification
solid fuel masonry or factory built fireplaces that have been Material which will not ignite and burn. Such materials are
installed in accordance with the National, Provincial, State those consisting entirely of steel, iron, brick,tile,concrete,
and local building codes. Fireplaces are to be constructed slate, glass or plasters, or any combination thereof.
of non-combustible materials and, in the absence of local
or regional codes,meet criteria of NFPA211. No additional Materials that are reported as passing ASTM E 136,
outside air source is required. Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 °C shall be considered
NOT/CE: This installation must conform with/oca/codes. non-combustible materials.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in F. Combustible Materials Specification
the U.S.A. and the CAN/CGA 8149 InstaUation Codes in
Canada. Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. and burn, whether flame proofed or not, or plastered or
This appliance is tested and approved as either supplemen- unplastered shall be Considered Combustible materials.
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations. G. Electrical Codes
B. Glass Specifications NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
This appliance is equipped with 5 mm ceramic glass. Re- of local codes, with National Electric Code ANSI/NFPA
place glass only with 5 mm ceramic glass. Please contact 70-latest edition or the Canadian Electric Code CSA
your dealer for replacement glass. C22.1.
C. BTU Specifications • A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection,in compliance
Models Maximum Minimum Orifice
Input Input s�Ze with the applicable electrical codes, when it is installed in
(U.S.oiCenadB) BTUIh BTUIh (DMS) locations such as in bathrooms or near sinks.
US 23,000 13,500 42
(0-2000 F�
COSMO•130-C (NG)
CANADA 20,700 12,150 43
(2000-4500 F�
US Zg,000 15,500 38
(0-2000 FT)
COSMO-135-C(NG)
CANADA 25,200 13,950 39
(2000-4500 F�
US 23,000 13,500 54
(0-2000 F�
COSMO-130-C�LP)
CANADA 20,700 12,150 55
(2000-4500 F7)
US 27,500 14,500 52
COSMO-135-C(LP) (0-2000 Fn
CANADA 24,750 14,000 53
(2000-4500 FT)
6 Heat&Glo • Cosmo-130-C,Cosmo-135-C • 2239-901 Rev.o • 6/14
Read this manual before installing or operating this appliance.
Please retain this owner's manual for future reference.
A. Congratulations This Owner's Manual should be retained for future
Congratulations on selecting a Heat&Glo gas fireplace,an reference. We suggest that you keep it with your other
elegant and clean alternative to wood burning fireplaces. important documents and product manuals.
The Heat&Glo gas fireplace you have selected is designed The information contained in this Owner's Manual, unless
to provide the utmost in safety, reliability, and efficiency. noted otherwise, applies to all models and gas control
systems.
As the owner of a new fireplace, you'll want to read and
carefully follow all of the instructions contained in this Your new Heat & Glo gas fireplace will give you years of
Owner's Manual. Pay special attention to all cautions and durable use and trouble-free enjoyment. Welcome to the
warnings. Heat&Glo family of fireplace products!
Homeowner Reference Information We recommend that you record the following pertinent
information about your fireplace.
Model Name: Date purchased/installed:
Serial Number: Location on fireplace:
Dealership purchased from: Dealer Phone:
Notes:
Listing Label Information/Location The model information regarding your specific fireplace can be found on
the rating plate usually located in the control area of the fireplace.
GAS•FIREO
H E AT�G L O�. Heat 8 Glo.a brand of Heart�8 Home Technologies
No ona builtl:a betror fire 7571 275th Street Weet,Lakeville,MN 55044 � u� ��
Type of Gas Not for use with solid fuel.
(Ne doit pas entre ud�ise avec un combustib�e so�ide). LISTED
Type ol Gas(Sorte Oe Gaz) Tnis appliance must be Installetl in acCOrdanCe wit�locel cotles,if any�,if not,follOw ANSI 2223.1
NA,�URAL GA$ ��meusno�ctwiccne�a���s�auauo��oaas(Insfallerlappareilselonlescodesoureglemenls
�ocaux ou.en I'absence tle te�s reglemenfs,selon les codes d'inslalla(ion CAWCGA-B749.)
ANSI Z27XX-XXXX•CSA 2.XX-MXX
Gas and Electric
Information
Minimum Permissible Gas Supply for Purposes of Input Adjustment.
Approved Minimum(De Gaz)Acceptable 0.0 in w.c. (PO.Col.d'eau)
Maximum Pressure(Pression) p.0 in w.c. (Po.Col.d'eau)
Maximum Manifold Pressure(Pression) 0.0 in w.c. (PO.Col.d'eau)
Minimum Manifold Pressure(Pression) 0.0 in w.c. (Po.Col.d'eau) Model Number
Total Electrical Requirements:OOOVac,OOHz.,less than 00 Amperes MADE IN USA
INCANADA Mode�: Serial Number
AITITUDE 0-0000 FT 0000-OOOOFT �odB1eJ: XXXXXXXX
MAX.INPUTBTUH: 00,000 00,000
MIN.INPUT BTUH�. 00.000 00,000
ORIFICESIZE #XXXXX #XXXXX Serial XX��XX
(Serie):
2 Heat&Glo • Cosmo-130-C,Cosmo-135-C • 2239-901 Rev.o • 6/14
14 Reference Materials
A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only.
A -
•-- H —=� --� S
O
Q
R
1' � G
�
T
1 .
B
, C .
�
F E � I
i �
0
J
d U M
GAS LINE K–�� � AC E SCAL —' •N �
ACCESS �
L
MODEL DIMENSIONS MODEL DIMENSIONS
COSMO-135-C COSMO-130-C COSMO-135-C COSMO-130-C
Location Location
Inches Millimeters Inches Millimeters Inches Millimeters Inches Millimeters
A 23-1/2 597 20-3/16 513 K 4-13/16 122 4-13/16 122
B 34-5/8 879 30-1/2 775 L 10-1/16 256 9 229
C 31-9/16 802 27-7/16 697 M 2-1/4 57 2-1/4 57
D 15-11/16 398 12-13/16 325 N 5 127 3-15/16 100
E 24 610 20-1/2 521 O 5-1/8 130 5-3/16 132
F 21-1/16 535 17-5/8 448 P 8 203 8 203
G' 15-7/8 403 14-5/8 372 Q 1-13/16 46 1-3/4 44
H 11-314 298 10-1/8 257 R 2-1/4 57 2-1/4 57
I 20-3/8 518 17 432 S 4-13/16 122 4-7/16 113
J 1-3/4 44 1-3/4 44 T 10-1/2 267 9-1/2 241
U 4-11116 118 4-9/16 115
*Note: Location G on Figure 14.1 is measuring the appliance depth, for installation depth reference Location G
on Figure 5.1.
Figure 14.1 Appliance Dimensions
Heat&Glo • Cosmo-130-C,Cosmo-135-C • 2239-901 Rev.o • 6/14 35
3 Framing and Clearances
A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
� M
. N -►
? �.
P
I�-- T --�I ' A {�-- ° �_
I
L
. • , �
� K
F �
B
� 1
' T G � •
Q :°, H � o:
.
S � I� J
R . p
E
Location Inches Millimeters Location Inches Millimeters
A 52 1321 K 46-3/4 1187
B 13-3/16 335 L 7 178
C 10-314 273 M 50-1/8 1273
D 42-3/4 1086 N 25-1/16 637
E 48-1/8 1222 O 18-5/8 473
F 21 533 P 9-1/16 230
G 4 102 Q 3-3/4 95
H 4-3/4 121 R 1-1/2 38
I 42-15/16 1090 S 8-1/2 216
J 18-1/8 460 T 14-1/2 368
Figure 3.1 Appliance Dimensions-RED40
Heat&Glo • RED40-NNN,RED40-NM,RED40-LM,RED40-NNN,RED40ST-LM,RED40ST-NM Installation Manual • 2155-975 Rev,D • 4/14 7