HomeMy WebLinkAboutB14-0362 Structural Steel Cover Report Date: November 6,2014 Location: Site Job Number: 14-6601 As scheduled, a representative arrived to perform special inspection services. The following is a summary of services provided on this date. As directed by Alex Coleman with Alpine Mountain Builders,GROUND inspected the following in unit 405: 1)Inspected welded connection of angle to existing HSS column and angle clip to new beam per section 3 on S2.1. These connections were found in compliance with project plans and in general compliance with AWS D1.1-10 clause 6. 2)Inspected bolted connections of column cap plate to new beam.These connections were found in the"snug tightened"condition,per project plans and in general compliance with Research Council of Structural Connections(RCSC). 3)Inspected anchor connections at HSS column base to foundation and found these were fully tightened per project plans. 4)Received and reviewed Welding Procedure Specification(WPS)and Welder Qualification Test record(WQTR)in accordance with AWS D1.1 for Vail Manufacturing. Alex was present during the inspections. Alex was E-mailed a copy of this report. Yes No Outstanding Discrepancies Reported this Date? © No. of Pages Attached: o Field Representative: Josh Bash DATE(MMIDDIYY' ) ,ace® CERTIFICATE OF LIABILITY INSURANCE 11/06/2014 �/ NEGATIVELY AMEND, EXTEND F ALTER IGH S UPON T AFFORDED TE HOLDER. POLICIES THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON ENSURER(S)HAUTDHORIZED BELOW. THIS DOES NOT AFFIRMATIVELY OF IN INSURANCE OR NE BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. must be endorsed. If SUBROGATION IS WAIVED,subject to tM terms and If the certificate holder policy,is rt ADDITIONAL may require INSURED,the policy(ies) the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). coNTA T Kyle Shimkus NAME: y FAX No 970-315-0147 PRODUCER PHONE , 970-328-0714 ' Kyle Shimkus(0707522) E-MAIL (ii -.ltt-l-.--•-t .t NAIC a 241 Broadway St Ste 101 ADDRESS: , a u INSURE' S AFFORDING COVERAGE 709 CO 81631-4327 INSURER 21 suRERA: Truck Insurance Exchan•e Eagle INSURER e: Fanners Insurance Exchange 21709 INSURED INSURER c: Mid Century Insurance Company EOM DESIGN PERFORMANCE ELECTRONIC - PO BOX 4257 -ilrill EDWARDS CO 81632 REVISION NUMBER: COVERAGES CERTIFICATE NUMBER: HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE THIS INDICATED.IS TO CERTIFY THAT DING POLICIES OF INSURANCE LISTED TERM OR CONDTION OF ANY COT CIES DE THEREDOCUREINTS TH ECP C ALOLLTHE H THIS CERTI ICA NOTWITHSTANDING BE ISSUED CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE EXCLUSIONS AND CONDITIONS OF SUCH PP�OTTL7SII1CIIEES.LIMITS SHOWN MAY HAVE BEEN REDUCED EBY PAID CLAIMS.EX P ILSRR TYPE OF INSURANCE IC61:a ,�"t`1�a POLICY NUMBER MMlDD MMIDDlYYYY EACH OCCURRENCE $ 1,000,000 GENERAL UABIUTY , , 100,000 PREMISESeEeoaurrence $ 5,000 © COMMERCIAL GENERAL LIABILITY MEO EXP(Any one person) $ X OCCUR 12/14/2013 12/14/2014 PERSONAL&ADV INJURY $ 1,000,000 ■■ CLAIMS-MADE 603294643 A ■ GENERAL AGGREGATE $ 2,000,000 ■ PRODUCTS-COMP/OP AGG $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER' $ PRO- . COMBINED SINGLE LIMIT 1,000,000 ■ POLICY LOC Ea accident $ AUTOMOBILE LIABILITY BODILY INJURY(Per person) $ I a ANY AUTO 046000238 05/03/2014 05/03/2015 BODILY INJURY(Per accident)- ■ALL OWNED ■ SCHEDULED PROPERTY DAMAGE NON-OWNED Per accident III HIRED AUTOS :AUTOS EACH OCCURRENCE $ ■ UMBRELLA LIAR ■ OCCUR AGGREGATE $ ■ EXCESS UAB ■ CLAIMS-MADE $ 111 DED 11 RETENTION$ ■ ai; ■ WORKERS COMPENSATION AND EMPLOYERS'UABIUTY Y/N E.L.EACH ACCIDENT $ ANY PR OR/PARTNER/EXECUTIVE I , E.L.DISEASE-EA EMPLOYE a $ OFFICER/MEMBER EXCLUDED? u (Mandatory in in NH) E.L.DISEASE-POLICY LIMIT S If yes,describe under DESCRIPTION OF OPERATIONS below I 1111 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remarks Schedule,It more apace Is required) 210 EDWARDS VILLAGE BLVD#C209,EDWARDS,CO 81532 CANCELLATION CERTIFICATE HOLDER SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Alpine Mountain Village aged Blvd ACCORDANCE WITH D T POLICY EOF, NOTICE WILL BE DELIVERED IN 105 Edwards Village Blvd / AUTHORIZED REPRESE A r'- Edwards CO 81632 Kyle Shimkus (4 1988-2� 0�a CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD Fire Health Hazard reHazard Cl) MATERIAL SAFETY DATA SHEET gyp Reactivity ® (OSHA 29 CFR 1910.1200) Personal Protection Q HMIS RATING NFPA RATING Effective Date: July 14, 2011 Supersedes: July 26, 2010 Page 1 of 2 SECTION I —PRODUCT INFORMATION 1. MANUFACTURER'S NAME AND ADDRESS: United States Mineral Products Company dba Isolatek International/CAFCO INDUSTRIES 41 Furnace Street Stanhope.NJ 07874 973-347-1200 2, EMERGENCY TELEPHONE NUMBER: CHEMTREC 703-527-3887 3. CHEMICAL NAME AND SYNONYMS Spray-Applied Fire Resistive Materials(SFRMs). 4. CHEMICAL FAMILY: Silicates and Calcium Sulfates 5. FORMULA: Slag Wool and Inorganic Binders 6 TRADE NAMES AND SYNONYMS: CAFCO® BLAZE-SHIELD®, CAFCO BLAZE-SHIELD WHITE, CAFCO BLAZE-SHIELD CHARCOAL, CAFCO BLAZE-SHIELD II, CAFCO BLAZE-SHIELD II WHITE, CAFCO BLAZE-SHIELD II CHARCOAL, CAFCO BLAZE-SHIELD HP, CAFCO BLAZE-SHIELD HP WHITE, CAFCO BLAZE-SHIELD HP CHARCOAL, SECTION II—HAZARDOUS INGREDIENTS/IDENTITY INFORMATION INGREDIENT CAS NUMBER OSHA PEL ACGIH TLV-TWA Slaa Wool 65997-17-3 NE 1 fiber/c Powdered Binders& Fillers N/Ap Total Dust: 15mg/m' 10mg/m Nuisance Particulates Respirable fraction: 5mg/m3 3mg/m3 SECTION III -PHYSICAL/CHEMICAL CHARACTERISTICS 1. Boiling Point("F). N/Ap 2 Vapor Pressure(mm Hg): N/Ap 3 Vapor Density(Air=1): N/Ap 4 Solubility in Water: Negligible 5 Specific Gravity(H2O=1): >1 6. Melting Point(°F): >1800 7 Evaporation Rate: N/Ap 8 Appearance and Odor: White to charcoal,low odor. 9. Physical State: Solid SECTION IV- FIRE AND EXPLOSION HAZARD DATA Flash Point(Method used): N/Ap 2, Flammable Limits. Noncombustible 3 Extinguishing Media: N/Ap 4 Special Fire Fighting Procedures: N/Ap 5. Unusual Fire and Explosion Hazards: None SECTION V-REACTIVITY DATA 1. Stability: Stable Conditions to Avoid: Contact with strong acids 2 Incompatibility(Materials to Avoid): Strong Acids 3. Hazardous Decomposition Products: CO,CO2 4. Hazardous Polymerization: Will not occur Conditions to Avoid: N/Ap NE=Not Established N/Ap=Not Applicable United States Mineral Products Company dba ISOLATEK INTERNATIONAL/CAFCO INDUSTRIES Page 2 of 2 MSDS (CAFCO" BLAZE-SHIELD`, CAFCO BLAZE-SHIELD WHITE, CAFCO BLAZE-SHIELD CHARCOAL, 7/14/11 CAFCO BLAZE-SHIELD II, CAFCO BLAZE-SHIELD II WHITE, CAFCO BLAZE-SHIELD II CHARCOAL, CAFCO BLAZE-SHIELD HP, CAFCO BLAZE-SHIELD HP WHITE, CAFCO BLAZE-SHIELD HP CHARCOAL) SECTION VI -HEALTH HAZARD DATA Primary Routes of Entry: Inhalation,Skin and Eye Contact,Ingestion. Acute: Slag wool and other nuisance particulates may cause transitory skin irritation(itching)and possible irritation of eyes and upper respiratory tract. Carcinogenicity: NTP-NO OSHA-NO IARC—3(Not classifiable as to human carcinogenicity) Medical Conditions Aggravated by Exposure: Any condition,which may be aggravated by mechanical irritants Emergency and First Aid Procedures: Eye Contact: *Flush with water. Skin Contact: 'Wash with water. Launder clothing separate from other garments. Inhalation: `Remove to fresh air. Ingestion: Do not induce vomiting. Seek immediate medical attention. 'If irritation persists,seek medical attention. USE NORMAL PERSONAL HYGIENE AFTER CONTACT TO REMOVE ANY MATERIAL CONTAMINANTS. California Proposition 65 Warning: This product contains substances known to the State of California to cause cancer,birth defects,or other reproductive harm. Chemical Name: Silica,crystalline CAS#14808-60-7 SECTION VII -PRECAUTIONS FOR SAFE HANDLING AND USE 1. Steps to be taken in case material is released or spilled: Sweep up and place in disposal containers. Avoid inhalation of dust. 2. Waste Disposal Method: Land Fill-In accordance with local,state,and federal regulations 3. Precautions to be taken in handling and storing: Avoid inhalation of dust during use. Avoid skin and eye contact. Use normal personal hygiene to remove material contaminants. SECTION VIII-CONTROL MEASURES 1. Respiratory Protection: Use NIOSH approved dust mask or equivalent for nuisance dust 2. Ventilation: Sufficient to maintain dust levels below TLV. 3. Protective Gloves: Wear gloves. 4. Eye Protection: Wear proper eye protection. 5. Other Protective Equipment: Wear Loose fitting long sleeve shirt and pants SECTION IX-PREPARATION INFORMATION Prepared By: Research Department, U.S.A. Telephone: (973) 347-1200 Effective Date:July 14, 2011 Supersedes:July 26, 2010 The information contained herein is based on data considered accurate. However, no warranty is expressed or implied regarding the accuracy of this data or the results to be obtained from the use thereof. VENDOR SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event shall the vendor be liable for special, indirect or consequential damages. Vendor assumes no responsibility for injury to vendee or third persons proximately caused by the material if reasonable safety procedures are not adhered to as stipulated in this data sheet. Additionally, vendor assumes no responsibility for injury to vendee or third persons proximately caused by abnormal use of the material even if reasonable safety procedures are followed. Furthermore,vendee assumes all risks in his use of the material. United States Mineral Products Company dba ISOLATEK INTERNATIONAL/CAFCO INDUSTRIES Page 2 of 2 MSDS (CAFCO" BLAZE-SHIELD, CAFCO BLAZE-SHIELD WHITE, CAFCO BLAZE-SHIELD CHARCOAL, 7/14/11 CAFCO BLAZE-SHIELD II, CAFCO BLAZE-SHIELD II WHITE, CAFCO BLAZE-SHIELD II CHARCOAL, CAFCO BLAZE-SHIELD HP, CAFCO BLAZE-SHIELD HP WHITE, CAFCO BLAZE-SHIELD HP CHARCOAL) SECTION VI - HEALTH HAZARD DATA Primary Routes of Entry: Inhalation,Skin and Eye Contact, Ingestion. Acute: Slag wool and other nuisance particulates may cause transitory skin irritation(itching)and possible irritation of eyes and upper respiratory tract. Carcinogenicity: NTP-NO OSHA-NO IARC—3(Not classifiable as to human carcinogenicity) Medical Conditions Aggravated by Exposure: Any condition,which may be aggravated by mechanical irritants. Emergency and First Aid Procedures: Eye Contact: *Flush with water. Skin Contact *Wash with water. Launder clothing separate from other garments Inhalation: `Remove to fresh air. Ingestion: Do not induce vomiting. Seek immediate medical attention. `If irritation persists,seek medical attention. USE NORMAL PERSONAL HYGIENE AFTER CONTACT TO REMOVE ANY MATERIAL CONTAMINANTS. California Proposition 65 Warning: This product contains substances known to the State of California to cause cancer,birth defects,or other reproductive harm. Chemical Name: Silica,crystalline CAS#14808-60-7 SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE 1 Steps to be taken in case material is released or spilled: Sweep up and place in disposal containers. Avoid inhalation of dust. 2. Waste Disposal Method: Land Fill-In accordance with local,state,and federal regulations. 3. Precautions to be taken in handling and storing: Avoid inhalation of dust during use. Avoid skin and eye contact. Use normal personal hygiene to remove material contaminants. SECTION VIII - CONTROL MEASURES 1. Respiratory Protection: Use NIOSH approved dust mask or equivalent for nuisance dust. 2. Ventilation: Sufficient to maintain dust levels below TLV. 3. Protective Gloves: Wear gloves 4. Eye Protection: Wear proper eye protection. 5. Other Protective Equipment: Wear Loose fitting long sleeve shirt and pants. SECTION IX- PREPARATION INFORMATION Prepared By: Research Department, U.S.A. Telephone: (973) 347-1200 Effective Date: July 14, 2011 Supersedes: July 26, 2010 The information contained herein is based on data considered accurate. However, no warranty is expressed or implied regarding the accuracy of this data or the results to be obtained from the use thereof. VENDOR SPECIFICALLY DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event shall the vendor be liable for special, indirect or consequential damages. Vendor assumes no responsibility for injury to vendee or third persons proximately caused by the material if reasonable safety procedures are not adhered to as stipulated in this data sheet. Additionally, vendor assumes no responsibility for injury to vendee or third persons proximately caused by abnormal use of the material even if reasonable safety procedures are followed. Furthermore, vendee assumes all risks in his use of the material. i .; INTERNATIONAL Fire Protection Products Leadership in Energy and Environmental DesignTM (LEED) Certification As the world's leading manufacturer of structural steel fire protection products, Isolatek International recognizes the value of designing buildings to meet the standards of the LEED Program. The LEED Green Building Rating System certifies entire projects on the basis of design and environmental impact. In addition to offering the broadest product selection of any structural steel fire protection manufacturer, our products combine high-recycled content in addition to local manufacturing locations. The following table identifies applicable LEED points: LEED Points: LEED Requirements: Applicable CAFCO LEED Guide Product: Reference: 10 Building achieves a All CAFCO SFRMs EA Credit 1 high level of energy performance. 1 Building Materials All CAFCO SFRMs MR Credit 5.1 manufactured within 500 miles of the project site. 3 Renovation Projects All CAFCO SFRMs MR Credit 1.1, 1.2, maintain existing and 1.3 building elements 2 Building materials See Table Below MR Credit 4,1 and contain recycled 4.2 content. 2 Low Volatile Organic All CAFCO SFRMs EQ Credit 4.1 and Compound (VOC) 4.2 Content 1 Construction Waste CAFCO 300, MR Credit 2.1 and Management; CAFCO 400, 2.2 recyclable waste FENDOLITE M-11 Bags (Kraft Paper) - All CAFCO SFRMs (wooden Pallets) 1 Raw Materials Supplied All CAFCO SFRMs MR Credit 5.2 Within 500 Miles of the Manufacturing Site. These values and credits should be confirmed prior to final acceptance The table below identifies the Isolatek International fire protection or thermal/acoustical product, its percent-recycled content, type of recycled content, and manufacturing location. Isolatek International Product %Recycled Type of Recycled Manufacturing Location Content Content CAFCO BLAZE-SHIELD' II 67% Post-Industrial Huntington, IN, (Pre-Consumer) Birmingham, AL CAFCO" BLAZE-SHIELDF HP 56% Post-Industrial Huntington, IN (Pre-Consumer) CAFCO' 300/400 10% Post-Consumer Stanhope, NJ CAFCO' 300/400 10% Post-Consumer Houston, TX CAFCO® 300/400 10% Post-Consumer Chandler, AZ FENDOLITE'" M-II 0% Not Applicable Stanhope, NJ Houston, TX CAFCO" HEAT-SHIELD' 90% Post-Industrial Huntington, IN 11 (Pre-Consumer) CAFCO-BOARDTM >75% Post-Industrial Wabash, IN (Pre-Consumer) SprayFilmTM WB 2 0% Not Applicable Lawrence, MA SprayFilmTM WB 3 0% Not Applicable Lawrence, MA SprayFilmTM WB 4 0% Not Applicable Lawrence, MA CAFCO BLAZE-SHIELD II and BLAZE-SHIELD HP are structural steel fire protection products that satisfy all AIA (American Institute of Architects) physical performance requirements for commercial and medium-density products, respectively. In addition to their fire protection capabilities, BLAZE-SHIELD II and BLAZE-SHIELD HP offer exceptional thermal value and acoustical benefits. BLAZE- SHIELD II and BLAZE-SHIELD HP are composed of 100% inorganic binders which make them mold/mildew resistant. CAFCO-BOARD is a rigid board fire protection product that provides hourly rating requirements for structural steel members, including floor and roof decks. CAFCO-BOARD is ideally suited to address sequencing issues such as roof construction and construction roof traffic, where sprayed fire protection is required. Due to CAFCO-BOARD being mechanically fastened to the substrate, it is unaffected by roof traffic during and after application. CAFCO-BOARD also offers exceptional thermal value and acoustical benefits. CAFCO HEAT-SHIELD, although not a fire protection product, is an effective thermal and acoustical treatment product. It can be applied at varying thicknesses dependent upon the R-Value or NRC (Noise Reduction Coefficient) Value required for the project. CAFCO 300 and CAFCO 400 are structural steel fire protection products that satisfy all AIA (American Institute of Architects) physical performance requirements for commercial and medium-density products, respectively. We appreciate your interest in CAFCO Fire Protection and Thermal/Acoustical products. Should you have further questions related to this matter, please do not hesitate to contact Isolatek's Technical Department at (800) 631-9600 • Commercial Density CAFCO® BLAZE-SHIELD® II Page 1 of 1 Cnmmerr.a!fireproofrng • IS T K We Save Lives® INTERNATIONAL i. 3i ani Products Application Projects Support About Us Industry Contact Us Corn m e rc i a l Density Products I Commercial Density I Medium Density I High Density C A F C O R BLAZE-SHIELD I E LD I I Intumescent Coatings I Thermal/Acoustical I Rigid Board l System Components CAFCO BLAZE-SHIELD II I CAFCO 300 I CAFCO 300 ES I CAFCO 300 SB I CAFCO 3304 Overview Testing Physical Properties CAFCO BLAZE-SHIELD'11 is the industry-leading commercial density Dry Mix Spray-Applied Fire Resistive Material(SFRM) It is art inorganic,environmentally friendly Portland cement-based formulation Mat provides superior fire resistance for structural steel and concrete in commercial construction environments This is the product of choice particularly when exposure to severe weather conditions during the construction phase is necessary when application efficiency. along with excellent thermal and acoustical insulation properties are desired VNth all of these added benefits it s wise to follow the advice of many of our customers -Don't just fire proof it BLAZE-SHIELD it CAFCO BLAZE-SHIELD II is the only commercial density product that is classified as investigated for exterior use by Underwriters Laboratories,thus allowing it to remain exposed to extreme weather conditions during the construction process ✓Benefits • Part of the most widely specified Dry Mix Spray family throughout • Inorganic material formulation does not promote mold or fungal the world for over forty years growth • Meets or exceeds all major fire protection specifications for • Portland cement-based formulation makes it suitable to remain Commercial structures including ANSI/UL 263,ASTM E119 and exposed to a variety of extreme weather environments during CANT ULC-5101 construction providing exceptional flexibility to sequencing and schetlul • Provides up to 4 four fire resistance ratings scheduling of projects • Low pressure pneumatic spray application equipment requires • Exceptionally high recycled content(67%pre-consumer)and other less manpower to operate environmentally friendly characteristics provide significant LEED credits • High thermal and acoustical properties provide thermal insulation and noise abatement capabilities Product Uses Applied directly to decking,steel beams columns or concrete surfaces for concealed commercial environments which may be exposed for prolonged periods of time during the construction cycle • • • • http://isolatek.com/cd-blazeshield-ii/ 4/5/2013 Commercial Density CAFCO® BLAZE-SHIELD® II Page 1 of 2 Commercial Fireproofing Aakvr.as , LATEK We Save Lives INTERNATIONAL Elf3n!' Products Application Projects Support About Us Industry Contact Us Commercial D e n s i tyy Products I Commercial Density I Medium Density I High Density C AF C O BLAZE-5 H I E L D• I I Intumescent Coatings I Thermal/Acoustical I Rigid Board i System Components CAFCO BLAZE-SHIELD II I CAFCO 300 I CAFCO 300 ES I CAFCO 300 SB I CAFCO 304 Overview Testing Physical Properties Fire Tests&Approvals In order to meet the performance and durability criteria set forth by the Amencan institute of Architects(AIA)and other major industry specifying organizations. CAFCOu BLAZE-SHIELD'II has undergone the most rigorous testing in accordance with the world's most demanding safety protocols Cellulosic-ANSI/UL263(ASTM E119) UL Classification Mark Factory Mutual New York City Materials and Equipment Acceptance iMEA) International Code Council-Evaluation ServtcetlCC-ES)Report Major Specification and Approval Compliance c c Cellulosic-ANSI/UL263(ASTM E119)-Fire Tests of ANSUULM).ASTM E-119 11$Ti TIme.Tempefmum Cone Building Construction and Materials Ye This cellulosic fire test is traditionally used to evaluate materials for use in the protection of modern day commercial structures This test reaches 1000"F(537°C)after 5 minutes and gradually reaches a temperature of E,-. I 2000`F 11093'C)alter a penod of up to 4 hours CAFCO BLAZE-SHIELD a is classified by Underwriters Laboratories for up I Ne"" to 4 hours protection in accordance with the cellulosic fire test and is listed within venous UL Designs • ?5 R T 7,, RN our • ae T> Yo w Top _ I UL Classification Mark •, SSIP/A The UL Classification Mark indicates compliance with global requirements as it relates to a O specific risk or casualty 'Nth the Classification service UL determines that a manufacturer has demonstrated the ability to produce a product complying with UL's requirements with respect to C US one or more of the following US is Specific risk e g casualty fee etc • Performance under specific conditions • Compliance with regulatory codes • Compliance with specific standards Such as international standards • Other condition as determined by UL All of the products carrying a UL Classification Mark are covered by UL's Follow-Up Services program to verify that products carrying the UL Classification Mark continue to be manufactured in compliance with UL s safety requirements Top A Factory Mutual CAFCO BLAZE-SHIELD II is a Factory Mutual(FMI approved product APPROVED E Top http://isolatek.com/cd-blazeshield-ii/ 4/5/2013 Commercial Density CAFCO® BLAZE-SHIELD® II Page 2 of 2 New York City Materials and Equipment Acceptance(MEA) An MEA Number is the number assigned to a product that has been approved for use in New York City by the MEA Division CAFCO BLAZE-SHIELD II has been reviewed and MEA numbers have been assigned BUILDINGSThe MEA division regulates certain materials and equipment(that)require Department of Buildings acceptance•These manufactured items affect public safety.health and welfare pndudmg structural stability and fire safety I and are usually a permanent part of a building Top r. International Code Council-Evaluation Service(ICC-ES)Report I CC International Code Council-Evaluation Services(ICC-ES)has conducted a technical evaluation t . of CAFCO BLAZE-SHIELD II The result of the evaluation process assures that the CAFCO BLAZE-SHIELD II is in compliance with the International Building Code LES . • • I Top r. Major Specification and Approval Compliance CAFCO BLAZE-SHIELD II complies with the requirements of the following specifications • General Services Administration(GSA) AIA/SCIGSA:07811 ■ Department of the Navy NAVFACENGCOM Guide Specification NFGS 07810.Sprayed-On Fireproofing is Veterans Administration(VAy H-08-1 • U.S ARMY Corps of Engineers CEGS-07811 ■ U S Environmental Protection Agency(EPA) Regulation 40 • Construction Specification Canada(CSC)TEK•AID Top^ 1 http://isolatek.com/cd-blazeshield-ii/ 4/5/2013 Commercial Density CAFCO® BLAZE-SHIELD® II Page 1 of 1 ti Commercial Fireproofing Anrerias IS 1LATEK We Save Liveso INTERNATIONAL Brand Products Application Projects Support About Us Industry Contact Us Commercial Density Products J Commercial Density ( Medium Density J Hugh Densay C AF C O; BLAZE-SHIELD I I Intumescent Ceatrngs I Thermal/Acoustical I Rigid Board ( System Composers CAFCO BLAZE-SHIELD It I' CAFCO 300 I CAFCO 300 ES I CAFCO 300 SB I CAFCO 304 r Overview Testing Physical Properties ASTM Physical Performance Standards Test Performance' Spray-Applied Fire Resistive Materials (SFRM's) Physical Property ASTM AIA MasterSpec/GSA CAFCOe BLAZE-SHIELD*II Standard Performance Requirements Surface Burning• ASTM E84 Flame Spread 10 or less 0 Characteristics Smoke Developed 0 0 Density ASTM E605 15 pcf(240 kg/ml) 16 pcf(256 kg/mi) Cohesion/Adhesion ASTM E736 150 psi(7 2 kPa) 375 psi(17 9 kPa) (Bond Strength) Deflection ASTM E759 No cracks.spatting or delamination No cracks spalling,or delamination Bond impact ASTM E760 No cracks.spelling or delamination No cracks spatting or delamination Cornpressve Strength ASTM E761 750 psf(35.9 kPat 2380 pit(114 kPa) Corrosion ASTM E937 Does not promote corrosion of steel Does not promote corrosion of steel Air Erosion ASTM 6859 Max 0 025 g/ft: 0 000 g/ft 2(0 000 g/m_i Fungal Resistance ASTM G21 Zero Growth After 28 days Zero Growth After 28 days Combustibility ASTM E136 Noncombustible Noncombustible 0 75 NRC 1/2"(13mm)on deck and beam Sound Absorption ASTM C423 0.75 NRC 1°125 mm)on solid base Thermal Properties ASTM C518 Conductivity(kJ-0 30 BTU in/hr fb=F @,,,75°F(0.043 W/mK a 25°C) Resistance 1Rlmch]-3 33 `Oared on independent laboratory tests under controlled conditions. http://isolatek.com/cd-blazeshield-ii/ 4/5/2013 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES mww or . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B14 -0362 Job Address: 728 W LIONSHEAD CIR VAIL Location......: Ritz Carlton Unit 405 Parcel No....: 210107223075 OWNER VAIL 202 LLC 09/16/2014 MASSMUTUAL 1295 STATE ST SPRINGFIELD MA 01111 Project #: PRJ14 -0508 Applied.....: 09/16/2014 Issued...: 09/30/2014 APPLICANT ALPINE MOUNTAIN BUILDERS INC 09/16/2014 Phone: 970 - 926 -8703 PO BOX 69 EDWARDS CO 81632 License: C000003134 CONTRACTOR ALPINE MOUNTAIN BUILDERS INC 09/16/2014 PO BOX 69 EDWARDS CO 81632 License: C000003134 Description: Add floor above kitchen. Remodel kitchen /living room. New interior door. New railing /interior glass wall. Kitchen includes: cabinets, countertops, plumbing fixtures, appliances & electrical Occupancy: R -2 Type Construction: IA Phone: 970 - 926 -8703 Valuation: $237,000.00 } w# R} RRt#**## Y# w##* w*} f}}}}} RRR*#* wwwwwMYR} fR}}} RRRrt *Y #YH*Rw }RYRRRRRRRRfRR * # * #Y FEE SUMMARY ## 1rt} w# wwR}} R* RR}**#*###### www} ww}} RR}} R* R*** YwYR # ####w }ww }wfR }RR}RRRRRR *R ** *w# Building Permit -- - - - - -> $1,760.95 Bldg Plan Check - - - - -> $1,144.62 Use Tax Fee------- - - - - -> $4,540.00 Electrical Permit - -- - -> $172.50 Elec Plan Check - -- - -> $112.13 Restuarant Plan Review - -- $0.00 Mechanical Permit - - - - -> $200.00 Mech Plan Check -- - - - - -> $50.00 Additional Fees------- - - - - -> $0.00 Plumbing Permit - - - - -> $75.00 Plmb Plan Check - - - -> $18.75 Recreation Fee------------ - - - - -> $0.00 Investigation ------ ---- ----- - - -> $0.00 Will Call----------- - - - - -- -> $20.00 TOTAL PERMIT FEES -- --> $8,093.95 Payments - - - -- — ---- -> $8,093.95 #*#} R}}}} RR }R }R *R * * # # #ww #wR }wRR *RR } } * # ## wwwwww# RRx} RRRRRww # # #www # #RRR #R }R } }RRR * * * ## wwwwww# x} R» RR} RRwRRwwx# wwxwwwwR}}} BALANCE DUE - - - - -- - - -> Rw# R}} R*## ww## ww}} R}}}} w*** Y* R*## # : #x #Rw }}R #RRRR $0.00 }RRRR*wwR * #Yww ## DECLARATIONS I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. combination permit - 012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B14 -0362 Address: 728 W LIONSHEAD CIR VAIL Owner: VAIL 202 LLC Location: Ritz Carlton Unit 405 Cond: CON0013940 CONTACT Vail Fire Dept for alarm and sprinkler requirements combination permit-012811 7DWNOF VAILV Permit #: B14 -0362 Owner: VAIL 202 LLC Unit 405 REQUIRED INSPECTIONS AND STATUSES Address: 728 W LIONSHEAD CIR VAIL Location: Ritz Carlton Item: 00120 ELEC -Rough Item: 00200 MECH -Rough Item: 00220 PLMB- Rough /D.W.V. Item: 00230 PLMB- Rough/Water Item: 00240 PLMB -Gas Piping Item: 00320 MECH- Exhaust Hoods Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00060 BLDG - Sheetrock Nail Item: 00070 BLDG -Misc. Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00420 Special Inspect -final rept Item: 00390 MECH -Final Item: 00090 BLDG -Final combination permit-012811 Department of Community Development -J 75 South Frontage Road TOWN OF VAIL ` Vail, Co 81657 Tel: 970 -479 -2128 www.valigov.com Development Review Coordinator BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 728 west lionshead circle 405 (Number) (Street) (Suite #) Building /Complex Name: Ritz Carlton Contractor Information Business Name: Alpine Mountain Builders Business Address: po box 69 City Edwards State: co Zip: 81632 Contact Name: alex Coleman Contact Phone: 970 376 4900 Contact E -Mail: alex @ambvail.com I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision coP s review - proved, International Building and Re ntial odes d o er ordinances of the Town applicable eto. Signature (Required) Applicant Information Applicant Name: Alex CQk PY���� Applicant Phone: 970 376 4900 Applicant E -Mail: alex @ambvail.com Project Information �1--� Owner Name: F\/a' o(,- ' (L('_ Parcel #: 210107223075 (For Parcel #, contact Eagle County Assessors Office at (970328 -8640 or visit www.eaglecounty.us/patle) For Office Use Only: r— Q Fee Paid: S Received From: Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Project #: DRB #: Building Permit #: _61q. 17310 a Lot #: c2—Block # Subdivision: L_)L*t- Work Class: New (mil Addition (0) Alteration ((� Type of Buildin Single- Family Duplex 0 Multi - Family Other, Work Type: Interior G Exterior O Both O Valuation of Work Included Plans Included Work Electrical Mechanical eyes O)No OYes Plumbing "Yes ONO OYes Building Mes ONo OYes Value of all work being performed: (value based on IBC Section 109.3 & IRC Section 11 Electrical Square Footage ONO '*e6 ° 6 ONo 6 1 ®)N G Dd U 0 )8.3) j as Detailed Scope and Location of Work: `(coy QCC%yc I �L �- CV_L/`J C06s5 tra:a t wile itA<.Ckiz — N -eLA-j � (use additional sheet if necessary) C t�CJ/v 1rtJ�5 �g=aU v is 2 014 in SEP 16 TOWN OF VAI "of upck4,�> cl �I Co-( 12- Mar -2012