Loading...
HomeMy WebLinkAboutB13-0477 REV14 Architectural plans CORRECTIONS REQDPlanSideElevation LEVASQUARE10'-6"-LS32Designedto90mph,ExpBRatedwhenumbrellaisfullyerected.Umbrellaweight:152lb.Boomweight:234lb.Overalldimensionsrepresentclearancedimensionsforthecompleteumbrella.Membranedimensionsdiffer,dependingonvariationsintensioningandfabrication.Alldimensionsarenominalandhaveatoleranceof+/-2".7'-5"clear11'-9"10'-6"overall8'-10"minimum10"14'-7"overall 10'-11"overallElevation 5'-3"5'-3"5"Note:Theumbrellas must be closedandtied beforewind speeds reachgustsof 60mph (100km/h) Refer note on Specification- Umbrella Design. Collar and arm in closed position. NOTE: Allow up to 2" sag due to stretch of membrane fabric. Arc of arm when opening. 7'-4" 7'-5" 6'-1" 4'-5" 3'-5" 3' 2'-11" 6'-7" 4'-11" 3'-3" 1'-8" 0 5" 7" OPENED POSITION CLOSED POSITION 10'-6" Side Support Square Umbrella Leva - Model LS32 BOOM *HSS4.500" Powder coat finish BASE PLATE 1014"x1014"x 34" pl. with Ø234" service hole. 4- 34" hold down bolts at712" o.c. F1554 Gr. 36 galvanized or stainless steel Gr.316. With dome nuts and leveling nuts. FABRIC, PVC PVDF coated Standard color, whiteCABLE S.S. Gr.316 with S.S. fittings ARM *HSS1.660" powder coat finish COLLAR *HSS4.000" powder coat finish (in opened position) COLUMN *HSS4.500" powder coat finish LOCKING BOLT stainless steel CABLE S.S. Gr.316 PVC coated ERECTION POLE Removed when open POLE *HSS3.500" Powder coat finish View square to boom View square to arm *All HSS and Pipe to befy=50 ksi min. Engineering Framing EF-LS32-07.10 Architectural Umbrellas Leva Model LS32 cBirdairInc.Thisdrawingmustnotbecopied,retainedorusedwithoutpermission Figureddimensionstakeprecedence.Donotscale. www.birdairumbrellas.com sales@birdairumbrellas.com Birdair Inc. PlanElevation Natural ground Plan Elevation 4- 34" F1554 Gr. 36 galvanized H.D. bolts with nuts and leveling nuts - 4" hook to suit level of top of paving, tiling, etc 238" min 6" max. 1'-5" embedment (cast in) 6x6-W5.5xW5.5 wire mesh top & bottom Natural Ground Non-shrink grout 712"o.c.Embedment Boltprojection Non-shrinkgrout4-34" H.D. bolts to be threaded rod grade F1554 Gr. 36 hot dipped galvanized, or stainless steel Gr.316. Supplied with nuts, washers and leveling nuts. Chemical anchors, at 712" x 712" centers to be 'Ramset Reo 502' (or 'Hilti HIT-RE 500'), orengineer approved equivalent, and to be installed in accordance with the manufacturer's instructions. Ø1'-6" 1'-6"min overlap 238"cover 712" 712" 4'-7" ====712" 712" 1'-8"5'2'-6"==Non-shrinkgrout 1' 4-#5 vertical #2 spiral at 1' pitch 238"min 6"max ChemicalAnchorDetail LS32 - Pier Footing LS32-PadFooting238"min.6"max.6"min. H.D. Bolt Layout Plan Not to scale 10'-6"overall 14'-7"overall 5'-3" 5'-3" 5'-3"5'-3" Footing Detail FD-LS32-08.10 Architectural Umbrellas Leva Model LS32 cBirdairInc.Thisdrawingmustnotbecopied,retainedorusedwithoutpermission Figureddimensionstakeprecedence.Donotscale. Notes: Designed to 90mph, Exp B Assumed soil conditions: Pad - bearing capacity 14.5 psf Pier - cu=7.25 psf (stiff clay) Minimum 238" cover to all reinforcement Concrete strength - f'c 3600 psi 34" aggregate size Slump 212" Anchor bolt location tolerances per Australian Standard AS 4800-1998 - 3mm for anchor bolt centers within an anchor bolt group. - 6mm for adjacent anchor bolt group centers. - Maximum accumulation of 6mm per 30m not to exceed a total of 25mm. - 6mm from anchor bolt group center to column line center. www.birdairumbrellas.com sales@birdairumberllas.com Birdair Inc.