HomeMy WebLinkAboutB13-0477 REV14 Architectural plans CORRECTIONS REQDPlanSideElevation LEVASQUARE10'-6"-LS32Designedto90mph,ExpBRatedwhenumbrellaisfullyerected.Umbrellaweight:152lb.Boomweight:234lb.Overalldimensionsrepresentclearancedimensionsforthecompleteumbrella.Membranedimensionsdiffer,dependingonvariationsintensioningandfabrication.Alldimensionsarenominalandhaveatoleranceof+/-2".7'-5"clear11'-9"10'-6"overall8'-10"minimum10"14'-7"overall 10'-11"overallElevation
5'-3"5'-3"5"Note:Theumbrellas
must
be
closedandtied
beforewind
speeds
reachgustsof
60mph
(100km/h)
Refer
note
on
Specification-
Umbrella
Design.
Collar
and
arm
in
closed
position.
NOTE:
Allow
up
to
2"
sag
due
to
stretch
of
membrane
fabric.
Arc
of
arm
when
opening.
7'-4"
7'-5"
6'-1"
4'-5"
3'-5"
3'
2'-11"
6'-7"
4'-11"
3'-3"
1'-8"
0
5"
7"
OPENED
POSITION
CLOSED
POSITION
10'-6"
Side
Support
Square
Umbrella
Leva
-
Model
LS32
BOOM
*HSS4.500"
Powder
coat
finish
BASE
PLATE
1014"x1014"x
34"
pl.
with
Ø234"
service
hole.
4-
34"
hold
down
bolts
at712"
o.c.
F1554
Gr.
36
galvanized
or
stainless
steel
Gr.316.
With
dome
nuts
and
leveling
nuts.
FABRIC,
PVC
PVDF
coated
Standard
color,
whiteCABLE
S.S.
Gr.316
with
S.S.
fittings
ARM
*HSS1.660"
powder
coat
finish
COLLAR
*HSS4.000"
powder
coat
finish
(in
opened
position)
COLUMN
*HSS4.500"
powder
coat
finish
LOCKING
BOLT
stainless
steel
CABLE
S.S.
Gr.316
PVC
coated
ERECTION
POLE
Removed
when
open
POLE
*HSS3.500"
Powder
coat
finish
View
square
to
boom
View
square
to
arm
*All
HSS
and
Pipe
to
befy=50
ksi
min.
Engineering
Framing
EF-LS32-07.10
Architectural
Umbrellas
Leva
Model
LS32
cBirdairInc.Thisdrawingmustnotbecopied,retainedorusedwithoutpermission
Figureddimensionstakeprecedence.Donotscale.
www.birdairumbrellas.com
sales@birdairumbrellas.com
Birdair
Inc.
PlanElevation
Natural
ground
Plan
Elevation
4-
34"
F1554
Gr.
36
galvanized
H.D.
bolts
with
nuts
and
leveling
nuts
-
4"
hook
to
suit
level
of
top
of
paving,
tiling,
etc
238"
min
6"
max.
1'-5"
embedment
(cast
in)
6x6-W5.5xW5.5
wire
mesh
top
&
bottom
Natural
Ground
Non-shrink
grout
712"o.c.Embedment Boltprojection Non-shrinkgrout4-34"
H.D.
bolts
to
be
threaded
rod
grade
F1554
Gr.
36
hot
dipped
galvanized,
or
stainless
steel
Gr.316.
Supplied
with
nuts,
washers
and
leveling
nuts.
Chemical
anchors,
at
712"
x
712"
centers
to
be
'Ramset
Reo
502'
(or
'Hilti
HIT-RE
500'),
orengineer
approved
equivalent,
and
to
be
installed
in
accordance
with
the
manufacturer's
instructions.
Ø1'-6"
1'-6"min
overlap
238"cover
712"
712"
4'-7"
====712"
712"
1'-8"5'2'-6"==Non-shrinkgrout 1'
4-#5
vertical
#2
spiral
at
1'
pitch
238"min
6"max
ChemicalAnchorDetail
LS32
-
Pier
Footing
LS32-PadFooting238"min.6"max.6"min.
H.D.
Bolt
Layout
Plan
Not
to
scale
10'-6"overall
14'-7"overall 5'-3"
5'-3"
5'-3"5'-3"
Footing
Detail
FD-LS32-08.10
Architectural
Umbrellas
Leva
Model
LS32
cBirdairInc.Thisdrawingmustnotbecopied,retainedorusedwithoutpermission
Figureddimensionstakeprecedence.Donotscale.
Notes:
Designed
to
90mph,
Exp
B
Assumed
soil
conditions:
Pad
-
bearing
capacity
14.5
psf
Pier
-
cu=7.25
psf
(stiff
clay)
Minimum
238"
cover
to
all
reinforcement
Concrete
strength
-
f'c
3600
psi
34"
aggregate
size
Slump
212"
Anchor
bolt
location
tolerances
per
Australian
Standard
AS
4800-1998
-
3mm
for
anchor
bolt
centers
within
an
anchor
bolt
group.
-
6mm
for
adjacent
anchor
bolt
group
centers.
-
Maximum
accumulation
of
6mm
per
30m
not
to
exceed
a
total
of
25mm.
-
6mm
from
anchor
bolt
group
center
to
column
line
center.
www.birdairumbrellas.com
sales@birdairumberllas.com
Birdair