SITE NUMBER:
DN01334E
•
lNo DATE DESCRIPTION
A 9/18/14PREllM ISSUE
B 9/22/14PREllM ISSUE o 10.L2/14-CONST I$SUE
II II II
2323 PELGANY STREET DENVER, CO 80216
~-cg"-~--U o/! ~
OCT 2 0 2014
DN01334E-SONNENALP CONDO TOWN OF VAil
oI
,
APPROVAL SIGNATURE BLOCK
THE FOLLOWING PARTIES HAVE REVIEWED THESE DOCUMENTS.
ALL DOCUMENTS ARE SUBJECT TO REVISION BY THE LOCAL ZONING BUILDING DEPARTMt;NTS AND MAY IMPOSE
CHANGES OR MODIFICATIONS.
o APPROVED
o REJECTED
PROJECT MANAGER (PRINT) PROJECT MANAGER DATE o APPROVED
o REJECTED
RF ENGINEER (PRINT) RF ENGINI;:ER DATE
[lAPPROVED
o REJECTED 10/3/2014Geoff Squier ~8!IIJ;ar~SITEJ.~I01~IIII'll8111 dPRINT) DigitallY signed by Jeanne Anderson SITE ACQJisn'lON I DATEIi;;C [T[ 'I 't: DN: cn=Jeanne Anderson. o. OU.
email=Jettnne.AndersonI88@T-QAPPROVED 10.3.14
~ An ders on 'Mobile.com, c=US [j REJECTED
" , Date: 2014.10.0312:36:35-06'00'
~ -T---M-O-BI-LE-Q-UALl-1Y-/JS~SU-RAN-CE (PRINT) T-M08ILE QUALl1Y ASSURANCE DATE C)
~
~ p
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 3:27 pm, Oct 21, 2014
-------
VENDOR:
tF --Mobile
2323 DELGANY S1ReET
DENVER. co 80216
T-MOBILE SITE NUMBER: DN01334E
T-MOBILE SITE NAME: SONNENALP CONDO
SITE ADDRESS: 501 N. FRONTAGE RD. WEST • -Mobile-
VAIL CO 816572323 DELGANY STREET DENVER, CO 80216 NEW EQUIPMENT AND ANTENNAS ON: EXISTING 31' ROOFTOP
~
SITE INFORMATION
SITE TYPE: ROOFTOP
SITE NAME: SONNENALP CONDO
SITE NUMBER: DN01334E
SITE ADDRESS; 501 N. FRONTAGE RD.
VAIL, CO 81657
COUNTY: EAGLE COUNTY
JURISDICTION: CllY OF" VAlL
OCCUPANCY TYPE: UNMANNED
A.DA. COMPUANCE: F"ACIUTY
HUMAN
APPLICANT: T-MOBILE WEST.
2323 DELGANY STREET
DENVER. CO 80216
(303) 313-6930
PROJECT MANAGER:
GREG LAUER
(303) 359-0015
SITE DEVELOPMENT:
GEOFFRY SQUIER
(303) 981-3578
II
II
II
PROPERTY OWNER:
SONNENALP RESORT OF" VAIL
SITE CooROINATES (NAD 83):
LATITUDE: N. 39.646361
LONGITUDE: W. -106.387498
GROUND ELEVATION: 8243' (AMSL)
TOWER OWNER:
SONNENALP RESORT OF" VAIL
20 VAIL ROAD
VAIL. CO. 81658
DESIGNER:
BRANCH COMMUNICATIONS. u.c
1516 SOUTH BOSTON AVE. STE 215
TULSA, OK. 74119
CONTACT: JAMES W MCCOY
PHONE; (918) 261-1875
ENGINEER:
SPECIALlY TELECOMMUNICATIONS SERVICES,
PRQFESSIONAL ENGINEERS AND
13431 N. BROADWAY. STE 120
OKLAHOMA CllY. OK. 73114
CONTACT: SAMUAL CURTIS
PHONE: (405) 753-7167
TELEPHONE COMPANY:
N/A
N/A
WEST
IS UNMANNED AND NOT FOR
HABITATION.
LLC
LLC
CONSULTANTS
POWER COMPANY :
VICINITY MAP N.T.S. I LOCATION MAP N.T.S.
DRAWING INDEX
DESCRIPTIONNO
TlTLE SHEETT1
SITE PLANCl
-~~~
EQUIPMENT PLANSC2
C3 BUILDING ELEVATIONS
RF"l ANTENNA RF DIAGRAM
ANTENNA LAYOUTSRF"2
RF" SCHEDULERF"3
EQl RRU MOUNT OPTIONS
Gl GROUNDING NOTES AND SCHEMATIC
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
NO DATE DESCRIPTION BY
A 9/18/14 PREUd ISSUE JPR
B 9/22/14 PREUM ISSUE JWM
o 10/2/14 CONST ISSUE JWM
SHEET TITLE:
TITLE SHEET
SHEET II: PROJECT II: IREV:T 1 IDNOE3~4£ 0BY: CKD:
_ JPR JWM
DO NOT SCALE DRAWINGS DRIVING DIRECTIONS
DEPART 80216 ON SR-2 [COLORADO BLVD] (SOUTH) 0.1 MI TURN LEFT (EAST) ONTO LOCAL ROAD(S) 21 YDS TURN LEFT (NORTH) ONTO
SR-2 [COLORADO BLVD] 174 YDS TAKE RAMP (RIGHT) ONTO 1-70 100.6 MI EXIT 176, TURN RIGHT 0.2 1.41 VAIL BEAR RIGHT (NORTH) ONTO
LOCAL ROAD(S) 10 YDS BEAR LEFT (WEST) 21 YDS BEAR LEFT 10 YeS BEAR LEFT 32 YeS BEAR RIGHT (SOUTH) ONTO VAIL RD 98 YDS A
ROUNDABOUT. TAKE THE FIRST EXIT ONTO S FRONTAGE RD W 0.6 Mf TURN RIGHT (NORTH) ONTO LOCAL ROAD(S) 142 YeS ARRIVE DN01334E.
:
I A&E DRAWING REVIEW SCOPE OF WORK
I TITLE: SIGNATURE: DATE: 1. REMOVE AND REPLACED (3) EXISTING ANTENNAS ON EXISTING
--ROOFTOP AT 34'.
IPROPERTY OWNER: 2. INSTAu. (3) FRLB GROUND LEVEL
IT-MOBILE CONSTRUCTION UGR: 3. INSTALL (1) F"eOA CABINET AND (1) SSC CABINET.
IZONING APPROVAL:
2
IRF" ENGINEER; ~..~ ~... ......~~"
SITE ACQUISITION:
ACCEPTED-WITH OR NO COt.AMENTS. CONSTRUCTlON IioIAY PROCEED
NOT ACCEPTED-RESOLVE COMMENTS AND RESUBMIT CALL COLORADO ONE CALL 811 n£ FOUDWIHG PNIT1E!! I£RI!IIY APPROVE AND ACCEPT THESE DOCIJIJjEllT!! AND AIJlHORIZE:
THE CON'TlW:TOl< TO PftOCEED WITH THE CONsmuenON DESCRIBED HERE1'N. AU. DOCUMENTS
(800) 922-1987 CALL 3 WORKING DAYS ARE SUBJECT 10 RE'VlEW er THE lDCAl BUIlDING DEPARTIAOO AND MAY IIiPOSE CHANGES OR MODIFICATlON'S. BEFORE YOU DIGI
PRODUCED BY: e
SPECWJY TELECOIIIIUNlCATIONS SERIIICES. u.c. PROFESSIONAL ENGINEERS AND CONSULTANTS
13431 N. BROADWAY. SUITE f20 OKLAHOIoIA CII'Y. OK 73114 {405> 753-7167
COA 120141417918
PRODUCED BY:
8R NCH
COMMlINICA TIONS,LLC
BRANCH CONt.llJNICAllONS 1516 5 SOSTON AVE STE 215 TULSA, OKI.AHOMA 74119
(918) 949-4551
CONTRACTOR SHAu. VERIFY Au. PLANS AND EXISTING DIMENSIONS
AND CONDITlONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY
THE ENGINEER IN WRITlNG OF" ANY DISCREPANCIES BEFORE
PROCEEDING WITH THE WORK OR BE RESPONSIBLE F"OR SAME.
CODE COMPLIANCE
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN
ACCORDANCE WITH THE CURRENT EDITIONS OF THE F"OLLOWING
CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITtES.
NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK
NOT CONFORMING TO THESE CODES.
2011 EDITIONNAnONAL ELECTRIC CODE:
INTERNATIONAL BUILDING: 2009 EDITION
INTERNATIONAL MECHANICAL CODE: 2009 EDITtON
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 3:27 pm, Oct 21, 2014
EXISTING ROOFTOP
ACCESS LADDER
/
I
EXISTINGI PENTHOUSEI
'J-
0 0
I
OVERALL SITE PLAN
SCALE: .....".........-a::
0' 10' 20' 30' 40'
------
II
I
...----EXISTING T -MOBILE
EQUIPMENT TO REMAIN:
(1) ANTENNA PER SECTOR
REMOVE AND REPLACE __
(1) PER SECTOR (TYP.)
L':: =/ EXISTING EQUIPMENT ROOM
EXISTING T-MOBILE
EQUIPMENT AREA
~
EXISTING T -MOBILE
EQUIPMENT TO
REMAIN: (1)
ANTENNA PER
SECTOR
EXISTING MW DISH
i // ~i..A f 21 L7 I ,:-----
GAMMA SECTOR ENLARGED
PLAN RE: RF2
ALPHA & BETA SECTOR
ENLARGED PlANS RE: RF2
EXISTING T-MOBILE _____....J
EQUIPMENT TO REMAIN:
(1) ANTENNA PER SECTOR
VENDOR:
~--Mobile
2323 DELGANY S1REET
DENVER, co 8021 II
PRODUCED BY; e
SPECIALlY Ta.ECQIAIUNICATIOIS
SERVICES, Ll.C. PROFESSlONIIL. ENGINEERS AND C01'4SULTANT'S lm1 N. BROADWII"., sum:: 120 ~C!'IY, OK 1a114
(.ws) 753-1181
COl. 120141417918
PRODUCED BY:
BR.NCH
COMMUNICA TIONS,LLC
BRANCH COMMUNICATIONS 1516 S BOSTON AVE STE 215 'TUlSA, OKlNiOf,jA 74119
(918) 949-<1551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
NOI DATE I DESCRIPTION IBY
@
TRUE NORTH
(9.21' E)
MAG
JPR
JWM
JWM
PROJECT
DN01334E I0SHEET /1:
BY: eKD:C1 JPR JWM
1
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 3:27 pm, Oct 21, 2014
I.
VENDOR:
~--Mobile
2323 DELCANY STR£Er
DENVER, co 80218
PRODUCED BY: e
SPECIALlY TEl.ECO!.INIJNICATItl'IS SEIMC£S, u.c.
PROFESSIONAL ENGINEERS AND OONSIJLTANTS 13431 N. BROADWAY, SUITE 120 OKlAHOMA CI1Y. OK 73114 (405) 753-7167
COA '20141417918
PRODUCED BY:
BR.NCH.I·
COMMUNICATIONS,LLC
BRANCH CONNlJNICAllONS
1518 S BOSroN AVE STE 215 TULSA. OKLAHOIIA 74119
(918) 949-4551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. fRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
NO DATE DESCRIPTION BY
IA 9/18/14 PREUM ISSUE JPR
B 9/22/14 PREUM ISSUE JWM
o 10/2/14 CONST ISSUE JW~
SHEET TITLE:
EQUIPMENT PLANS
SHEET {/: PROJECT H: IREV:
C2 DN01334E 0BY: IICKO: JPR JWM
6'-0" 6'-0·
~
PPC
EXISTING TELCO CABINET
REMOVE
T -MOBILE CABINET
l
r~.EXISTING NODE B STAND
EXISTING CONCRETE ~snNG CONORm
EXISTING BUILDING WALL
llD'
PAD
EXISTING BUILDING WALL.-/ I II ~ II'I
I EXISTING
EXISTING PPC CABINET •en I
EXISTING U2100 STACKED ;.... EXISTING U2100 STACKED
ON TOP OF' EXISTING ON TOP Of EXISTING PPC
CABINET CABINET
(3) PROPOSED T-MOBILE
MOUNTED TO EXISTING WALL
REt..4OVE EXISTING ___
T -MOBILE CABINETS
EXISTING
T-MOBILE
'hMAGNA TEl< BBU .I I")(To BE
REMOVED)
71 j j I Ifitt It j I!
9" k 2'-6" ~ 1'-6" 2'-0·EXISTING T-t..40BILE
STEEL PLATFORM Ii Ii ,/ "EXISTING T -MOBILE 7'-6"7'-6" STEEL PLATfORM
fRLB
o
o
1r==L. ~ ~
I - I -. " \ ,,~
PROPOSED
T-MOBILE
F'COA
CABINET
EXISTING TELCO CABINET
EXISTING PPC CABINET
. <t
. en I ;....
p~rowT-t..40BILE 0
SSC .' I;"CABINET N ~
.-JIIIIIIIII~
@ @
TRUE NORTHTRUE NORTH
(9.21' E)
1 MAGEXISTING EQUIPMENT PLAN 2 ~!!~:~SED EQUIPMENT PLAN I ('~~
!SCALE: I 10' 0' I' 5' 0' l' 5' 10'
DESIGN REVIEW
ADMINISTRATIVE APPROVAL
By jspence at 3:27 pm, Oct 21, 2014
dI\ T-MOBlLE.~NTENNAS
V ELEV. = .,"t
EXISTING T -MOBILE ANTENNAS,
REMOVE (1) ANTENNA PER
SECTOR AND REPLACE (1)
T-MOBILE ANTENNA, REMOVE
(3) TOTAL AND REPLACE (3)
TOTAL
TOP OF PENTHOUSE $
ELEV. = 37'-8"
ROOFTOP .....
ELEV. 31' "
1 NORTH BUILDING ELEVATION
SCALE: N.T.S.
VENDOR:
tF --Mobile
2323 OELGANY S'ffiEET
DEIMR, co B0216
PRODUCED BY: e
SPECW.1Y mEOOMllUNICATIOIIS SER\IlC.ES, W::.
I'ROftSSIONAL EIIGINEERS AND CONSULTANTS 13431 N. B/IOADWAY. SUITE 120
0I<lJ,H0Mi\ CItY, OK 731 H
(..as) 753-7187
COA 120141417918
PRODUCED BY:
BR,c.NCH
COM~UN!cA 770NS,U.C
ElRANCH COI.tt.IUNICA11ONS 1516 S BOSTON AVE STE 215 TULSA. OKtAHO...... 74119
(918) 949-~1
SITE NAME:
SONNENALP CONDO
I
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
a. TOP OF PENTHOUSE
'lip ELEV. '" 37'-S" "'-
EXISTING T-MOBILE ANTENNAS.
REMOVE (1) ANTENNA PER
SECTOR AND REPLACE (1)
T -MOBILE ANTENNA, REMOVE
(3) TOTAL AND REPLACE (3)
TOTAL
,..,---,.....z:==
ROOFTOP ....
ELEV. = 31' "
PROPOSED T -MOBILE CABINETS
lNo DATE DESCRIPTION BY
IA 9/18/14 PREUM ISSUE JPR
B 9/22/14 PRELIM ISSUE JWM
o 10/2114 CONST ISSUE JWM
SHEET TITLE:
BUILDING
ELEVATIONS
SHEET I: PROJECT fJ: p<c.v:
DN01334E 0C3 BY;~eD;---i JPR JWM
2 EAST BUILDING ELEVATION
SCALE: N.T.S.
ANTENNA NOTES:
1. ANTENNA CONTRACTOR SHALL INSURE THAT ALL ANTENNA MOUNTING PIPES ARE
PLUMB.
2. COAXIAL FEEDERS AND FlBER LENGTHS INDICATED ARE APPROXIMATE-VERIFY IN
FlaD PRIOR TO FABRICATION.
3. ANTENNA COAXIAL FEEDERS AND ANTENNA JUMPERS SHALL BE COLOR CODED PER
T -MOBILE REQUIREMENTS.
4. MULTI-ORT ANTENNAS: TERMINATE UNUSED ANTENNA PORTS WITH CONNECTOR CAP
AND WEATHERPROOF THOROUGHLY. JUMPERS FROt-l Tt-lA'S MUST TERt-lINATE TO
OPPOSITE POLARIZATIONS IN EACH SECTOR.
5. CONTRACTOR MUST FOLLOW ALL MANUFACTURERS RECOMMENDATIONS REGARDING THE
INSTALLATION OF COAXIAL CABLES, CONNECTORS AND ANTENNAS.
6. CONTRACTOR SHALL RECORD THE SERIAL NUMBER, SECTOR AND POSITION OF EACH
ACTUATOR INSTALLED A THE ANTENNAS AND FURNISH INFORMATION TO T-MOBILE.
7. WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF AMALGAMATION TAPE.
8. ANTENNA CONTRACTOR SHALL PERFORM A "rAPE DROP' MEASUREMENT TO
CONFIRM/VAUDATE ANTENNA CENTER LINE (ACL) HEIGHT. CONTRACTOR SHALL SUBMIT
A COMPLETED HEIGHT VERIFICATION FORM TO THE CONSTRUCTION MANAGER.
TMA NOTES:
1. ALL TMA'S SHALL BE PROVIDED PER RFDS FOR ASSOCIATED TECHNOLOGY.
RRU NOTES:
1. RRU TYPES
LTE RRU-FRIG
UMTS RRU-FRIA
GSM RRU-F'XFB
covp NOTES:
I. COVP PLACEMENT WHEN HYBRID CABLE USED:
BASE-(1) HIGH CAPACITY
TOP OPTION 1-(1) HIGH CAPACITY (ALL RRU'S WITHIN 15 FT. OF COVP)
TOP OPTION 2-(1) COVP EACH SECTOR
TOP OPTION 3-(2) LOW AND (1) HIGH CAPACITY (ALL RRU'S CANNOT BE PLACED
WITHIN 15 FT. OF COVP AND (4) SECTOR SITE. (2) SECTORS SHARE COVP)
VENDOR:
ql--Mobile
2323 DEJ..GANY STREET OENVER. co 802111
PRODUCED BY: e
SPECIAllY TELECOMNUN1CA11ONS SElMCES. u.e. PROfESStONAL ENGINEERS AND CONSlilT!IN'fS 1J.4.31 N. I!RO.\OWAY, SUITE 120 0t<LAH0MA CITY. OK 7311<4
(o4Il5) 753-7167
CQI\ 1201<41<417918
PRODUCED BY;
BRNCH
COMMUNICATIONS,LLC
BRANCH eot.fMUNlCAllONS 1516 S BOSTON AVE STE 215
TULSA, OKlAHOWI 74119
(918) 9<19-4551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. wEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
Configuration 700C GUN
(FRLB Ground undlplexed on Its oWn antenna)
(Antenna &.cabli/lQ of anesOOor shown for claritY) Drawing Date; 612412014
Biali-T ·C~~~~qlHPlll~nt) ~ uS<iBias-HorL100
"!mIBJma rtelisting Pes
antenna is non-RET
, Upgraded ,. capable.lfPcS
£lquipment
Reconfigured
.eqOJpment
antenna is RET
eapable,daisy chain ___LIO.9tg~siln!e'2n~__ _
I
ANTENNA RF DIAGRAM
SCALE: N.T.S. "DETAIL PROVIDED BY OWNER·
NO DATE DESCRIPTION
I" 9/18/14 PREUM ISSUE
B 9/22/14 PRELIM ISSUE
o 10/2/14 CONST ISSUE
SHEET TITLE:
BY
JPR
JWM
JWM
ANTENNA RF DIAGRAM
PROJECT II: (REV:SHEET 1/:
DN01334E
BY: lCKD:RF1
JPR JWM 1 0
EXISTING T -MOBILE ANTENNAS (TO
REMAIN) (1) PER SECTOR (TYP.)
VENDOR:
q? -Mobile
232.3 DEl.llANY S'lREET
DENVER. co 80216
PRODUCED BY:
SPECIALTY m.ECOIoIIoIUNICATIONS SERlllCES, LLC.
pAOf'tSSlOlW.. OOINEERS AND OONSULTNmi 13431 N. BROADWAY. sum: 1.20 OI<I.AHOIIIA CITY. 01( 131 H
(-lOS) 753-1161
OOA 1201414119111
PRODUCED BY:
BR.NCH
COMMUNICA TIONS.l.LC
BRANCH cot.IMUNICATIONS 1516 S BOSTON AVE SIt: 2HI
TULSA. OI<l.AHOliA 14119
(918) 949-4551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
NO DATE DESCRIPTION BY
IA 9/18/14 PREUM ISSUE JPR
B 9/22/14 PREUM ISSUE JWM
o 10/2/14 CONST ISSUE JWM
SHEET TITLE:
ANTENNA LAYOUTS
SHEET *: PROJECT .~: IKI:.V:
RF2 ~t~ 0JPR JWM
I
I
(RE-USE HEX AS A QUAD)
I
I
r
EXISnNG
EQUIPMENT
ROOM
BETA
I
A-2
ALPHA
I ? 1. AZlMU!li
BETA
EXISTING T -MOBILE ANTENNA WITH
TMA'S (TO REMAIN) (1) PER SECTOR !
(TYP.)
J LII
r I
EXISnNG MW DISH ~ EXISTING MW DISH
EXISTING
EQUIPMENT
ROOM
L
B-1EXISTING T-MOBILE ANTENNAS EXISnNG T -MOBILE ANTENNAS(TO BE REMOVED) (TO REMAIN) (1) PER SECTOR
TMA'S (TO REMAIN) (1) PER SECTOR
EXISTING T-MOBILE ANTENNA WITH AZIMUTH 160'
(TYP.)
I I EXISTING CABLE TRAY EXISTING CABLE TRAY
! I EXISTING ROOFTOP PIPE MOUNTED I EXISTING ROOFTOP PIPE MOUNTED I TO BUILDING ROOFTOP I TO BUILDING ROOFTOPLVr lY;=
EXISTING ROOFTOP TRI-POD
MOUNTED TO BUILDING ROOFTOP
GAMMA
240'AZIMUTH EXISTING T -MOBILE ANTENNA[~I=A24(rl
EXISTING T-MOBILE TMA'S EXISnNG T-MOBILE TMA'S(TO BE REMOVED)
EXISnNG T-MOBILE ANTENNAS (TO EXISTING T -MOBILE ANTIENNAS (TO
REMAIN) (1) PER SECTOR (TYP.) REMAIN) (1) PER SECTOR (TYP.)
GAMMA GAMMA
@
TRUE NORTH (9.21' E)
1 MAGEXISTING ANTENNA AZIMUTH PLAN 2 PROPOSED ANTENNA AZIMUTH PLAN
SCALE: N.T.S. SCALE: N.T.S.
A-2
ALPHA
L Af;f.~'AZ~
BETA
A-I
EXISTING ROOFTOP TRI-POD
MOUNTED TO BUILDING
ROOFTOP
REPLACE
T-MOBILE ANTENNA. WITH L700
ANTENNA
@
TRUE NORTH (9.21' E)
MAG
REMOVE AND
ANTENNA SCHEDULE
STATUS ANTENNA AZIMUTH RAD CENTER ANTENNA MODEL H RRU!TMA TECH fEEDUNE
POSmON (OEG) (fEET) TYPE
<PROPOSED Al 100' 34' ANDREW LNX-6512DS-Al~ (1) FRLB LlE 700 (2) 7/8"
~Q! (E)
0..0 --;;;!8 EXISTING A2 100' 34' ANDREW TMZXX-6516-A3M (2) ADCP-OD 1900 LTE/pCS/ (4) 7/S"
~ AWS/UMTS (E)
"" LTE/PCS/ (2) 7/8"m EXISTING Bl 160" 34' ANDREW TMBXX-6516-R2M (2) ADCP-OD 1900
<~ AWS/UMrS (E)
t:i~ --tIlt) w (1) FRLB (4) 7/S" ~ PROPOSED B2 160" 34' ANDREW LNX-6512DS-Al~ LTE 700 (E)
8 PROPOSED Cl 240' 34' ANDREW LNX-6512DS-Al~ (1) FRLB LTE 700 1 5/S" ~Q! ::E~ -
<5fr\ EXISTING C2 240' 34' ANDREW TMBXX-6516-R2M (1) FXFB LTE/PCS/ 1 5/8"~ AWS/UMrS
COLOR COOING PROVIDED BY T-MOBILE
NOTES:
1. VERIFY RF DESIGN WITH LATEST RFDS AVAILABLE AT TIME OF ISSUE.
2. AZIMUTHS BASED ON TRUE NORTH.
3. EXISTING ANTENNA MODEL NUMBERS PER AUDIT.
VENDOR:
~. -Mobile
2323 IlELGANY STREET
DENIiat co 80216
PRODUCED BY: e
SPECIALTY TIiLECOIoIMUNlCiUIONS SEJM<:E:S, W::. PROFESSIONAL. ENOINEERS AND CONSULTANT'S 13431 N. SROAIlWAY, surrt 120 ClKlJIHOMA CllY, OK 731!-4·
(4(5) 753-1'181'
CO.t. 120141-+17918
PRODUCED BY:
BR.>LNCH
COMMUNICATJONS,LLC
BRANCH COMMUM~nONS 1518 S BOSTON AVE STE 215
TULSA. OI<I..AHONA 74119
(918) 949-4551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
NO DATE DESCRIP110N
IA 9/18/14 PRELIM ISSUE
B 9/22714 PREUM ISSUE
o 10/2/14 CONST ISSUE
BY
JPR
JWM
JWM
SHEET TiTlE:
RF SCHEDULE
PROJEcTt: IRI:.V:SHEET I:
BY: eKD:
JPR olWMRF3 fl~~~ ~, J 0
COMMSCOPE LNX-6515DS-A1M
RAOOME MATERIAL: FIBERGlASS. UV RESISTANT
RAOOME COLOR: LIGHT GRAY
DIMENSIONS. HxWxD.ln (mim) 96,42·x 11.8S·x 7.1" (2449x301 x 181 mm)
ji«-'VALVJ\NILW UNISTRUT
TO MEDIUM OR
TO WALL
SUITABLE ANCHOR
PlPE WEIGHT: 50.27 Ibe
CONNECTORS: TED
{'-'-MOUN11NG BRACKET
",~"""""""',,,', ,
. ' '~ < ...........
, .. " ,"':'~
•IN... .0 en
RF MODULE
RF
MODULE
~~.IJ s
RF CONNECTORS
RF CONNECTORSSIDE V!EW
S!DE VlEW
OUT
1 PLINTH TO WALL DETAIL 2 PLINTH TO POLE DETAIL 3 PROPOSED ANTENNA SPEC. DETAIL
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S.
ol
NEW RRU ~~:::::"'!..o-----Tr"lII" NEW T -MOBILE '1 FRIG
J
1-5/B"'~\UN/-STRUT FRAME ' NEW RRU~ \
NEW RRU PUNTH ~., " , , ' ','
NEW PUNTH ""''\
\ NEW 1-5/8" VNISTRUT X2, ', '1; ID';:!:\ PE~OR~til~y-W:A~~\ '~'" , '>
\1 ,I-Y HARDWAAE?r':I_-,...J.,__~_""""'_"-,.\0..-~,'I
!
GRATING EX. CABLE TRAY.,....., "
"W-SECTION wiTH
CUPS AT 12" OC
!CABLE TRAYSUPPORr vARIEsl
EXlsnNGUHISTRUT e~~;-""-RRU AlTACHMENT Will BEl SURFACEpIN P2346 "INEW W6X9 t SIMIUAR ON ALL cABLE TRA'!5J AlTACH TO SUITABLE ANCHOR (EXPANSION
SUITABLE
1''XIS" GW SERIES BAR
AlTACH TO
lYP£ ....."
(24" )(24!
SECTION)
(24ft LONG) - - ,
SUPPORT WITH '
..,. (4)
PER BEAM MINIMUM
ANCHOR
',...-" ANCHORS OR ~ft THRU-BOLTS)ANCHORS
4 NEW RRU STAND 5 PLINTH TO CABLE TRAY DETAIL 6 _F_R_IG_H_-F_RA~M_E______________
SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. ~, ~
I
VENDOR:
~--Mobile
2323 DELGANY STREET
DENVER. CO 80216
PRODUCED BY:
SPECIALTY 1'E1.ECOI.INUNICATIONS SERVIC£S. LLC. PROFISSIONAL ENGINEERS AND CONSULTANTS
13431 N. III!!WlWAY. SUITE 120
0KlN10"'A CITY, OK 731 H
(405) :153-7167
COA 1201.1+17918
PRODUCED BY:
BRNCH
COMMUNICA noNS.l.l.C
BRANCH COI.IhlUNfCA11ONS 1516 S BOSTON AVE STE 215 TULSA, 0KWt0IIA 74119
(918) 949-4551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAIL CO 81657
PROJECT NUMBER:
DN01334E
BYDATE DESCRIPTIONNO
JPR
B
[A PRELIM ISSUE9/18/14
JWMPREUM ISSUE9/22114
JWMCONST ISSUEo 10/2/14
SHEET TITLE:
RRU MOUNT OPTIONS
PROJECT J IRE.V:
ON01334E
BY: tICKO:
SHEET II:
0EQ1 JPR JWM
GROUNDING NOTES: o All. DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL GROUNDING INSTALl.ATION AND
CONSTRUCTION MAY VARY DUE TO SPECIFIC SITE CONDITIONS.
\i) COAX GROUND BARS: EXTEND (2 EACH) #2 TINNED, SOUD BCW BURIED GROUND RING
UP TO EACH GROUND AND MAKE MECHANICAL CONNECTIONS TO GROUND BARS.
(J;; BEFORE ATTACHING A NEW GROUND TO AN EXISTING, CONTRACTOR IS REQUIRED TO
PERFORM A GROUND TEST TO DETERMINE IF AMOUNT OF RESISTANCE PRESENT IS
WITHIN ALLOWABLE UMITS «5 OHMS). NEW SYSTEM MUST BE TIED OFF AT 2 POINTS
BY EXOTHERMIC WELD WITH INSPECTION PORTS INSTALl.ED AT EACH BONDED POINT. A
SECOND GROUND TEST IS REQUIRED AFTER INSTALUNG NEW GROUND AND MUST BE
WITHIN ALLOWABLE UMITS «5 OHMS).
Q GROUND ROO SPACING IS 10'-0~ MAX.
\£;} THE BURIED GROUND RING CONDUCTORS AND TOP OF GROUND RODS SHALL BE
BURIED A MINIMUM DEPTH OF 2'-6" BELOW FINISHED GRADE, OR 6" BELOW FROST
UNE, WHICH EVER IS DEEPER.
\iJ THE BURIED GROUND RING CONDUCTORS SHALL BE {/2 SOUD BARE TINNED COPPER.
(;) PROVIDE 10 FT. OF GROUND WIRE COILED UP AT TERMINATING LOCATION FOR F1JTURE
CONNECTIONS TO EQUIPMENT (CABINETS, MONOPOLE, COAX BRIDGE, FENCING, ECT.)
BEING INSTALLED AT A LATER DATE THAN THE GROUNDING INSTALLATION.
(i) THE #2 AWG GREEN Isew MAY RUN IN THE CABLE TRAY PARALLEL TO COAX CABLE.
DO NOT ATTACH OR FASTEN THE GROUND IRE TO THE COAX CABLE.
NpTES;NtTENNAS AND CABlE PERPiAN 1. THIS IS A DIAGRAMMATIC REPRESENTATION ONLY.(QUANTRYICONFlGURAlION(1 SEE SITE PLAN FOR FINAL EQUIPMENT LAYOUT.VARIES)
NUt.lBER OF RRU'S AND:~~ 2. oeSERVE NEC.' AND LOCAL UTILITY REQUIREMENTS(XM>'S VIR( (SEE RF RRU ~~ RRUCONFlGURA11ON ..
iX. . GRQUHO
lEAD
HYBRID CABlE
RUN PER PlAN
r~-
l
f1------,-Ie
1--~,''';::' ,:L
WG~r-
sse DR I!'X. IIIlI
j "-~'-~l
i'fX,CIIIINrilt!! llWI1I FRld \ TrP. I ~ ~ ~ ! I I
SHm'j RRU FOR ELECTRICAL SERVICE GROUNDING,~RRU
''-.sPUi:E (lYP)
r~,CABLE PER PLAN I ~ OR J) ~___..."
U,.1"fICU
EX. E'QUIP"ENT~,-_"..;c ORM 00 G Q G G 0 Ii C GG co
., .. ~ -it ....,. . .'. • • • • • •"'"'~~j --~-.
,~~."":O!t~_'......;.;,;",.".~. '-'
1 GROUNDING SCHEMATIC
SCALE: N.T.S. dZ0, ~
NO DATE DESCRIPTION BY
iA 9/18/14 PREUM ISSUE JPR
B 9/22/14 PREUM ISSUE JWM
o 10/2/14 CONST ISSUE JWM
SHEET TITLE:
GROUNDING NOTES &
SCHEMATIC
SHEET 1/: PROJECT .~: ~EV:
G1 DN01334E 0BY; ICKO; JPR JWM
VENDOR:
~--Mobile
2323 DELGNiY STR£ET DENVER, co 80218
PRODUCED BY: e
SPEClALT'I' TElECOIoIIIUNIOI\TIONS SDMCES, LLC. PROFESSlON.II. ENGINEERS AND OONSULTN«S
13431 N. I!I!()AI)WAY, SUITE 120 0I<l.AH0MA CIT'I'. 01< 73114
(-405) 753-7167
COA 120141417918
PRODUCED BY:
BR .•'{:NCH
COMMUNICATIONS,LLC
BRANCH COMI!IUNlCATIONS
1515 S BOSTON AVE STE 215
TULSA. OKlAHOMA 74119
(918) 949-+551
SITE NAME:
SONNENALP CONDO
SITE NUMBER:
DN01334E
SITE ADDRESS:
501 N. FRONTAGE RD. WEST
VAlL CO 81657
PROJECT NUMBER:
DN01334E