Loading...
HomeMy WebLinkAboutB14-0354 plans approved . � ' . . SKAAL HUS UNIT 1 � � . . � , ' 1 i41 W . MEADOW DR . VAI L, CO 81657 A,. �;. r� .,�� � � �' ���: �; / . �... � � �: �� � �� �" fy �� '�: L , �.� , .����� � � � . '��'� r _.a���' ��/�/1 ��`� �.� i FC�R PERMIT & �C7NSTRUCTIC�h� // � Q � � _ �L r� ,� D� � ��� _ � KEY PLAN - l�REp OF NEW VIIC�Rl; ���;To sca�E \� � � li � � GENERAL NOTES 1.- DO NOT SCALE DRAWINGS 2.- THE GENERAL CONTRACTOR FOR THIS PROJECT SHALL COORDINATE ALL WORK WITH SUB-CONTRACTORS. GENERAL CONTRACTOR SHALL ORDER ALL MATERIALS UNLESS OTHERWISE NOTED. ALL SUB-CONTRACTORS SHALL VERIFY ALL DIMENSIONS&EXISTING CONDITIONS ON THE JOB SITE PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIAL,NOTIFY OWNER OR ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3.- PLAN DIMENSIONS AT EXG WALL ARE TO FACE OF FINISH WALL,PLAN DIMENSIONS FOR NEW WALLS ARE TO FACE OF STUD OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. 4.- ALL NEW WALLS SHALL ALIGN WITH ADJACENT EXISTING SURFACES. ALL NEW WALLS WHICH REQUIRE PATCHING WILL HAVE THE NEW TEXTURE. PAINT ENTIRE WALL IF ANY PATCHING HAS BEEN PERFORMED. 5.- ALL NEW WALLS SHALL BE 4"(NOM)WOOD STUDS @16"O.C.(MAX)UNLESS OTHERWISE INDICATED WITH ONE LAYER OF e'GYP. BD ON EACH SIDE. 6.- ALL NEW DOORS,UNLESS DIMENSIONED ON PLAN,SHALL BE CENTERED IN WALL WHERE POSSIBLE OR THE ROUGH OPENING SHALL BE PLACED A MINIMUM OF 6"AWAY FROM THE NEAREST WALL. 7: PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS,LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES,CABINEfRY,COUNTERTOPS, SHELVES AND RETAIL FIXTURES. 8: ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR 9: THE G.C.SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE 2012 INTERNATIONAL BUILDING CODE&2012 INTERNATIONAL ENERGY CONSERVATION CODE. CODE COMPLIANCE IS MANDATORY, THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING ALL LOCAL AND REGIONAL CODES. ___ _ _- _ __ ._ __ 5 S - _ . _ �T _ � � i � 'p Y\�iz..�4 i,-S i...A !� ! 'f� �".`f* ,?. �—� �`�%E'.._v'v t_L. .�M Pl., !:� �. �te._- �:�� PROJECT INFORMATION ADDRESS/LOCATION: OCCUPANCY/ZONING: BUILDING CONSTRUCTION TYPE: EXG.BUILDING: EXG.AREA PER STORY: BEARING WALLS,INT.&EXT.: FLOOR CONSTRUCTION: ROOF CONSTRUCTION: SCOPE OF WORK: l�, �� -� 141 W.MEADOW DR. BLDG. SKAAL HUS UNIT 1 VAIL,CO R-2(MULTI-FAMIIY RESIDENTIAL) TYPE VA 3 SOTRIES(NO CHANGE) +/-g,$p0 S.F.(NO CHANGE) 1 HOUR FIRE-RAITNG REQ'D 1 HOUR FIRE-RAITNG REQ'D 1 HOUR FIRE-RAITNG REQ'D NEW FINISHES ON FLOOR 8 WALL$ NEW LOCATION OF MECHANICAL ROOM NEW INTERIOR DOORS NEW LIGHT 8.BATH FIXTURES r. � � �:t�'�`� �a �/e�l� � ������ � �': ,..J�s '�a � ,. �. ��� No�o < E Z � �� < w � � Q` Q / 2 � � 0 `n 3 � O 2 p J Q Q w Q � � w N 3 v � � PR0.IECT NO. zaia-0s-oz � A0.0 ' - 0 � \"J � � �� • 1 • � f Mech Room�3-e� a� ,. , 'o m i�_d. ,�m��rrarT��n�� ,� �._b. z_a. Bathroom 3'-10' � _„jn� �� � ,,�. ��-,�- f �, ,._o. ` ,o• Master Bedroom ,._o. � 1 � � T_s�. Concrete Patio LEVEL 1 Z_9. Qi � O U D DEMOLITION &CONSTRUCTION FLOOR SCALE: 3/16" = 1' LEVEL 2 LEVEL 4 Bedroom#1 Closet � , I• I _-�� f� 8._B. Bathroom L / 3 � Up to UL _ � Bedroom#2 , , y'�a., 'r�V���'V�� r�i e ,P �a� ���3 Close Existing Window . ,� Open wall for new window � Cover With Quiet-rock Existing Block Wall LEVEL 3 � Demolition of Existing Wall €�.ti.�.�.* � �� Remove existing windows/patch with Stuccio to match New Drywall Wall(Regular) ,ti.. �� New Drywall Wall(Water Proo� /�` Z W �� $ �--� 4�W ��� � � W� U� m' � W� `� � E � =H � m� UZ m_ � �� �� � � I z Q � O O ' U Q J � �_ > O � p , � N � _ � O J Q Q N Z � w � � � ; � v I� � 0 � � U Z O ; a o �, PROJECTNO. 2014-09-02 A0. 1 � . ' � ' New location for wash &Dryer w/new plumbing and electrical connections Existing Demising wall-No work New Wall New location of Water Heater New Wall/Adjust framing at bathroom to eliminate notch in bathroom,move existing doors to new locations New Electrical Panel location All new bath fixtures Relocate electrical panel and Boiler to crawl space connect new Mech. Eq.to existing Flue New Wall New Fixed Window Remove 6cg.Window, Patch Exterior with Stucco to match A FIRST FLOOR SCALE: 1/4"= 1'-0" N OTE: NO EXTERIOR WORK WILL BE PERFORMED WITHOUT DESIGN REVIEW APPROVAL. '� +� C � � � � (� � U J U . T__ move existing drywall dropped ceiling in / throom, hallway and staurwell to create more head clearance . �� �i � // � � . . �. �. .� � E � O � N m � N � � t0 � �. � i . ` � i`�- .�; f�,���R g p .., Z � � - .�` i.��;� � ��� _ ���; Vtf� ry � � O �-+ fd a. � � U C 0 U New Fixed Window New Metal Stair 1 1 Risers @ 7-3/4" 11 Trades Q 11" Existing Wall to be Removed New Window Wall 1 A4.5 'VI E���� }'NI P� ie.�.,. �v - � —f 5` �. G� � � a � �W �f� 0 /�� U� N ui �a =�� � W E UZ � m � � Qo �� � Q � O U � � Q > Z � � � �%i > , � � 2 � 0 J w Q � � w � 3 v z Q � � O O � N � J Q � � � w � 2 U � Q PRQIECT N0. 2014-09-02 REV Sepbmber0],2011 REV OcbEer 02.2014 A1 . 1 � i � _ _. ,,,�_ � . , . �Y'�'" A SECOND FLOOR SCALE: 1/4" = 1'-0" NOTE: NO EXTERIOR WORK WILL BE PERFORMED WITHOUT DESIGN REVIEW APPROVAL. :( � U NZ �--+ �N $� � W ��� �o o� �� � n\ U _ O </��J r� a LL E VJ =w � � � �Z m € � Qo gi � a ' � , II I � U J � ¢ % Z Z Q J � � O � � � p O N U � O "' = o ¢ J Q � Q w � � UQ � w � N w I = 3 v v Q G i a S� a S PRO,IECT N0. 2014-09-02 Rev sacremeero�,zoi� REV OeEOber02,201� A1 .2 � --� ♦ • � , Existing CMU Demising wall -no work Relocate handrail to opposie wall. New handrail to comly with 2012 IBC Section 1012 Stairs remain as is Cut down stair wall and replace with glass @36" high New Kitchen cabinets and fixtures. Fixtures remain in place A� THIRD FLOOR SCALE: 1/4"= 1'-0" NOTE: NO EXTERIOR WORK WILL BE PERFORMED WITHOUT DESIGN REVIEW APPROVAL. C N L U Y � z N (� $ J 0 tn J a - ao t Q �,�i F 1,%1��� :�� D C By:�. New Window Wpll Existing Wall to be Removed �`� ' �`�` � `! .� .. .�°7/±�- �j i �. ;. ' ...._ .. . r:' .� � _" V �.. ' � � ,��%� y I I I � I I � SPACE BETWEEN WALL k HAN�RAIL SNALL NOT BE LESS THAN 1-1�2� � O O � � C J Edge of new deck Y U N 0 New Metal Stair 1 1 Risers Q 8" 11 Trades Q 10" HAN�ftAIL SHALL E%TEND — FROM TOP NOSING TO BOTTOM NOSING OF STAIR,U�IN. A� HANDRAIL DETAIL . SCALE: 3/4"= 1'-0" d � � HnNORna sHn��eE nrTncHEO rc wn�� OR NEWEL POST AN�SHALL EXTEND TO TOP STEP MINUMUM GRIP SIZE OF HANDRAIL SHALL HAVE AN OUTSIDE�IAMEiER OF AT LEAST 1-i/4" _ k NOT GREATER THAN 2 INCHES OR COMPLY W/IBC 2012,SECTION 10123 HEIGHT OF HANDRAIL MEASURED FROM PLANE OF NOSING TO TOP OF RqIL �IREC�Y ABOVE / / / / i/ � HAN�RAIL NOTES fPER 2012'BCl U N � � O �° �m� /�\ V� N�� <N F�-0.• a� 'w W E � ¢� �� � � Q � O U � Q > Z � � � `n 3 � O 2 p J Q Q w Q � � � w N 3 � z ¢ a � O O � � _ � Q � � � U w � 2 U � Q PRO,IECE N0. 2014-09-02 REV SBqemExO].ZOf1 REV Ocloper02,2011 � � A1 .3 � J Existing CMU Demising wall -no work Install new metal cable railing between existing posts. Posts rail shall be 36"above the floor and railing shall be less than 4"o.c.horizontally Posts to remain Ships ladder down to level 2 to remain A FOURTH FLOOR SCALE: 1/4" = 1'-0" NOTE: NO EXTERIOR WORK WILL BE PERFORMED WITHOUT DESIGN REVIEW APPROVAL. � 'N^ vI 0 Q � � Q � 0 � � ° 'a � � � � y L 0 M J 0 a � t 3 c� -°a .s�;=t�v ;' ry 4 C*" �f , ,_� ' ✓ a � r"„ , �v. R F'.1� p' �:r',.� . �� ld����% �u- .;,t �,, . REVi�vv� �OMPL1� Date:�_ Bua ._.. ( U � 2 �— ( � / � U ' NZ � �N � � W �m� 0 ^, Hd' N m� W W� a�� /� F W � E V/ ~ u� � Q� �� � Q a � � O U J � a 1 Z � � 0 `n 3 � O _ 0 J �Q Q � � w N 3 � z g � � O � _ � � 0 Q � � H U w F- 2 U � Q � � � � PROJECE N0. 2014-09-02 flEV Seplember0],201d REV Oelo0er02.2011 � A1 .4 � I A WEST ELEVATION SCALE: 1/4"= 1'-0" ` '. ' �� 3 �y 1 a..:��>�V e �• ti= REVI�V�1 �;OMF�° ` �te:.. ;� � { � d _ � - � � � U � Z � $ +� N 0 0 �m�YY 7 N�� ^, U� W WO a'� �W �LL E � �Z ��� Q O g'� � Q � o �. U ' J � � � Q ,f O 3 � � = o W J �Q w Q <L < w> �[ w II > N 3 v � � � PRQIECT N0. 2��4-09—�2 A2. 1 � �� . ' • '. A WEST ELEVATION SCALE: 1/4"= 1'-0" � �' . � . .�Q , .�.� ��� �.��� i�@: �o _ �� _ f � �� Existing Wall to be Removed New Window Wall L LENGTHWISE SECTION SCALE: 1/4" = 1'-0" � / / I � � / � � // LI I G ROOM � � j / � � / MASTER BEDROOM � � ;� ,� , TV LOFT Not for sleeping porpuses / � I 13 KITCHEN 11 10 9 8 7 6 5 4 � 2 1 \ ;� �, � � .�/y BEDROOM 1 u�� � vi :�V I EVi� �MPL� lo Z.� _ r5'� ate:�. � By: .,._,,��,. ROOF 8167.44 THIRD FLO 8153.90 FIRST FLO� 8146.44 � U NZ � �� �� W ��g � O ❑ o� �\ U� y <N WK a_ r -LL E � /^ w .� VJ �z m.m � QD �� � a � O U J � a > Z � � 0 `� 3 � O 2 p J �Q Q �� Q � � w `n 3 � Z O � U w N w � _ � � Z w J W � � � a o �� PRQIECT NO. 2014-09-02 � A2.3 � LEVEL 1 - WATER HEATER LOCATION WATER HEATER SPECS D MECHANICAL FLOOR PLAN &SPCES SCALE: 1/4"= 1'-0" LEVEL 2 - BOILER LOCATION BOILER SPECS TRIANGLE TUBE Prestige Solo It is a sealed unit Condensing High Efficiency Gas Boiler Satinless Steeel Fire Tube Heat Exchanger 95% AFUE Low Presure Drop Has a door closer & sealer for a smoke barrier per IBC 716 �EV���v�r �OMf�� Date:�. By: __.__� �� . Z�- �, � �/ U � Z � �--+ ¢� - O �w _ - �o � �� � � �W/'� U O ¢ ° � w� V/ ~w LLE V~ `� m � � ? m ; ¢� a� � a � � U J � � 1 Z � � 0 � � � O 2p J Q Q w Q � � � N N w 3 � 'o N U w d � z ¢ � � O O � Q U Z Q _ U w � � 3 0 PI20JECT NO 2014-09-02 M . 1 � D MOKE&CO DETECTOR-ALL FLOOR PLAN SCALE: 1/8"= 1'-0" O� SMOKE DETECTOR WILL BE LACATED INSIDE OF ALL BEDROOMS �o CO (CO & SMOKE COMBINED DETECTOR) WILL BE LOCATED IN ALL S� COMMON AREAS INSIDE OF THE UNIT U N Z � � O �° ��� /�, U� N o� W W� a_ //'� �� -LL E VJ ~ � E � �Z m` s� Q❑ $i � Q � Q U J � ¢ � % Z � � � `n 3 = O 2p J Q Q w Q � � � w N 3 v Z Q J d � � � J LL � O � U w � w � � U od w � O � � ..� �•� �� �� �� �� �� �� � � � � � � � � GENERAL NOTES 1. L'IVE LOADS USED IN DESIGN: A. ROOF B. TYPICAL FLOOR C. EXTERIOR DECK D. WIND 3 SECOND GUST FASTEST MILE EXPOSURE 100 PSF 40 PSF 100 PSF 90 MPH 100 MPH B E. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE. F. CODE USED IN DESIGN: INTERNATIONAL BUILDING CODE, 2012 EDITION. 2. TESTING, INSPECTIONS AND OBSERVATIONS: A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION. STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE. B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS SPECIFICALLY WAIVED BY THE BUILDIN6 OFFICIAL. 1. SOIL PREPARATION a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILL AND IN-PLACE DRY DENSITY OF THE COMPACTED FILL FOR CONFORMANCE WITH THE APPROVED REPORT. 2. CONCRETE CONSTRUCTION a. PERIODIC INSPECTION OF REINFORCING STEEL. b. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX. c. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE CONCRETE. d. CONTINUOUS INSPECTION OF CONCRETE AND PLACEMENT FOR PROPER APPLICATION TECHNIQUES. e. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES. 3. STEEL CONSTRUCTION a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTION EXCEPT THE FOLLOWING: 1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN ACCORDANCE WITH SECTION 1704.3. b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS, WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS ARE MADE OF WORK IN PROGRE55; AND A VISUAL INSPECTION OF ALL WELDS IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP WELDING. 1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE. 2. WELDING OF STAIRS AND RAILING SYSTEMS. c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED. d. PERIODIC INSPECTION OF THE STEEL FRAME TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE APPROVED CONSTRUCTION DOCUMENTS SUCH AS BRACING, STIFFENING, MEMBER LOCATIONS AND PROPER APPLICATION OF JOINT DETAILS AT EACH CONNECTION. Monroe & Newell Engineers,Inc. P.O.Box 1577 70 Bcnchmark Road,Suitc 204 Avon.Colorado 8 L620 (970)949-7768 FAX(9"70)949-4054 EMAIL avon@monroe-newell.com e. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFIED MILL TEST REPORTS. f. PERIODIC VERIFICATION OF HIGH STRENGTH BOLTS, NUTS AND WASHERS FOR CONFORMANCE TO ASTM STANDARDS SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE. g. PERIODIC INSPECTION OF BEARING TYPE CONNECTORS WITH HIGH STRENGTH BOLTS. 1. WHILE THE WORK IS IN PROGRESS, THE SPECIAL INSPECTOR SHALL DETERMINE THAT THE REQUIREMENTS FOR BOLTS, NUTS, WASHERS AND PAINT, BOLTED PARTS AND INSTALLATION AND TIGHTENING IN SUCH STANDARDS ARE MET. FOR JOINTS REQUIRED TO BE TIGHTENED ONLY TO THE SNUG-TIGHT CONDITION, THE SPECIAL INSPECTOR NEED ONLY VERIFY THAT THE CONNECTED MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY SNUGGED. 3. FOUNDATIONS A. THE ALLOWABLE SOIL BEARING PRESSURE ASSUMED IN DESIGN IS 2000 PSF. THE CONTRACTOR SHALL RETAIN A LICENSED SOILS ENGINEER TO INSPECT THE FOUNDATION EXCAVATION. SOILS ENGINEER SHALL VERIFY IN WRITING THE ACTUAL SOILS CAPACITY IS EQUAL TO OR GREATER THAN ASSUMED. B. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARING ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE. C. ALL FOOTINGS ARE TO BE PLACED ON FIRM, UNDISTURBED, NATURAL SOIL OR PROPERLY COMPACTED BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL SHALL BE COMPACTED TO 95% (MINIMUM) MODIFIED PROCTOR DENSITY PER ASTM D1557 UNLESS OTHERWISE RECOMMENDED IN THE SOILS REPORT. IF SOFT SPOTS ARE ENCOUNTERED REMOVE SOIL AND RECOMPACT WITH APPROVED FILL (RE: SOIL REPORT FOR DESCRIPTION OF BEARING SOIL). D. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF FOUNDATION WALLS IN 12 INCH MAXIMUM VERTICAL LIFTS OR AS RECOMMENDED IN THE SOILS REPORT. REFER TO SOILS REPORT FOR BACKFILL MATERIAL. E. CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRID LINES UNLESS NOTED OTHERWISE ON PLANS. F G H CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TESTS ON COMPACTED FILL UNDER FOOTINGS AND INTERIOR SLABS-ON-GRADE. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAY BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE. FOR SOIL DRAINAGE REQUIREMENTS REFER TO SOILS REPORT AND CIVIL DRAWINGS. 4. SLAB ON GRADE A'. THE PREPARATION OF THE SUBGRADE FOR THE SLAB ON GRADE SHALL BE IN STRICT ACCORDANCE WITH THE PROJECT SOILS REPORT REFERENCED ABOVE. THE CONTRACTOR SHALL DIRECT QUESTIONS REGARDING THE SUBGRADE PREPARATION REQUIREMENTS TO THE GEOTECHNICAL ENGINEER. B. MOVEMENT OF THE SLAB ON GRADE MAY CAUSE DAMAGE TO ANYTHING CONNECTED TO BOTH THE SLAB AND OTHER PORTIONS OF THE SUPERSTRUCTURE. ISOLATION DETAILS FOR PARTITION WALLS, BASEBOARDS, PIPING AND OTHER ITEMS MAY BE REQUIRED. REFER TO THE APPROPRIATE DRAWINGS OR CONSULT WITH THE RESPONSIBLE MEMBER OF THE DESIGN TEAM PRIOR TO CONNECTING ITEMS TO BOTH THE SLAB ON GRADE AND OTHER PORTIONS OF THE SUPERSTRUCTURE. SKAAL HUS -UNIT 1 RENOVATION VAIL, EAGLE COUNTY, COLORADO NO.#9638 � CONTINUED ON SS TITLE: GENERAL NOTES r� �� � ���� / DATE:09-16-2014 REVISION 9/26/14 C� J SCALE:AS NOTED DRAWN BY:AVN 5. CONCRETE A. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT, STONE AGGREGATE AND SNALL SATISFY THE FOLLOWING REQUIREMENTS: CONCRETE ITEM FOOTINGS FOUNDATION WALLS INTERIOR SLABS ON GRADE F'C MIX TYPE 2500 psi STD 2500 psi STD 3000 psi STD MAX W/C RATIO % AIR REQ. 0.50 --- B. CONTRACTOR SHALL SAWCUT OR TROWELCUT 70INT5 IN SLABS ON GRADE. ]OINTS SHALL BE SPACED 10 FEET AND SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X 3/16" WIDE WITHIN 12 HOURS AFTER POURING. CARRY ALL SLAB REINFORCEMENT THROUGH 70INT. C. SLABS, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE ENGINEER. D. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE STANDARD HOOKS FOR DOWELS UNLE55 NOTED OTHERWISE. ALL EXPOSED EDGES OF CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER. 6. REINFORCEMENT A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BE LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER. C. REINFORCEMENT PROTECTION UNLE55 NOTED OTHERWISE: 1. CONCRETE POURED AGAINST EARTH 3" 2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH) 2" 3. COLUMNS AND BEAMS (TIE BARS) 1-1/2" 4. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4" D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH SECTIONS 7.5, 7.6 AND 7.7 OF ACI 318, LATEST EDITION. E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER UNLESS NOTED OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS. F. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS IN CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY AT EACH CORNER. G. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED AS FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS. 7. STRUCTURAL STEEL A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICH SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B, LATEST EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION. MISCELLANEOUS EMBEDDED ITEMS SHALL BE A36 STEEL. Monroe & Newell SKAAL HUS -UNIT 1 RENOVATION Engineers,Inc. VAIL, EAGLE COUNTY, COLORADO P.O.Box 1597 - 70 Benchmark Road,Suitc 204 Avon,Colorado S 1620 (970)949-7768 FAX(970)949-4054 NO.#9638 EMAIL avon�a monroe-newelLcom B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307 UNLESS NOTED OTHERWISE. C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION." D. EXCEPT WHERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. WHEN LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60� THE TOTAL UNIFORM LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM AND SPAN. E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS-D1.1. F. MINIMUM WELDS TO BE PER AISC TABLE J2.4 BUT NOT LESS THAN 3/16" CONTINUOUS FILLET UNLE55 NOTED OTHERWISE. G. PROVIDE TEMPORARY BRACING AND PRECAUTIONS NECESSARY TO COMPLY WITH ALL STEEL ERECTION STANDARDS AND TO WITHSTAND ALL CONSTRUCTION AND/OR LATERAL LOADS UNTIL ALL FIELD CONNECTIONS ARE COMPLETED AND PERMANENT LATERAL SYSTEMS AND DECKS ARE IN PLACE. 8. NON-SHRINK GROUT A. NON-SHRINK GROUT SHALL BE PROVIDED: 1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS. 2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRY SUPPORTS. 3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE. 9. WOOD A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOU6LAS FIR, LARCH, GRADED BY WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL BUILDING CODE AS FOLLOWS: 2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI 2" TO 4" THICK - 6" AND WIDER N0. 2 Fb = 900 PSI 5" THICK - 5" AND WIDER N0. 1 Fb = 1350 PSI NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITVE USES PRIOR TO ALLOWABLE STRESS INCREASES. B. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER). C. TREATED SILL PLATE LUMBER MAY BE HEM-FIR, STRUCTURAL #1 GRADE. D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X WOOD JOISTS. SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS IS REQUIRED. E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE TABLE 2304-9.1 UNLESS NOTED OTHERWISE. F. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD. 1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD ASSOCIATION. CONTINUED ON S6 TITLE: GENERAL NOTES s�aa�.ia .�.,. , /°�, _ L�— r�/ ( � DATE:09-16-2014 REVISION 9/26/14 C C JJ SCALE:AS NOTED DRAWN BY:AVN 2. 3. 4. 5. 6. 7. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE WEATHER SHALL BE OF THE EXTERIOR TYPE. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG INTERMEDIATE SUPPORTS. FOR ROOF USE 5/8" (40/20 SPAN RATING) EXPOSURE I SHEATHING NAILED WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG INTERMEDIATE SUPPORTS. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR OSB SHEATHING NAILED WITH Sd (OR 10d) NAILS AT 6" ON CENTER ALONG PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES SHALL BE BLOCKED. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS. G. WOOD DECK WOOD DECKING SHALL BE 2x T&G DOUGLAS-FIR LARCH (E=1,700,000 PSI, Fb=1450 PSI). PLANKS SHALL BE SPLICED AT CENTER OF SUPPORT MEMBERS WITH ADJACENT PLANKS SPLICED AT ALTERNATE SUPPORT MEMBERS. EACH DECK PLANK SHALL BE SLANT-NAILED TO THE TONGUE OF THE ADJOINING COURSE WITH 8d NAILS AT 24" ON CENTER WITH ALTERNATE PLANK NAILING OFFSET 12". NAIL EACH PLANK TO EACH SUPPORT WITH (2)-16d NAILS-1 STRAIGHT, 1 SLANTED. WOOD DECKING SHALL BE GLUED IN THE GROOVE 70INT WITH 40� GLUE COVERAGE. H. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS AND SHALL BE "BCI-JOIST" AS MANUFACTURED BY BOISE CORPORATION. ALTERNATES SHALL BE REVIEWED BY THE ENGINEER. TO BE CONSIDERED, ALTERNATES SHALL HAVE A LOAD CAPACITY IN BENDING, SHEAR AND DEFLECTION EQUAL TO OR GREATER THAN THE SIZE SHOWN ON THE DRAWINGS. WEB BLOCKING AND BRIDGING TO BE AS REQUIRED BY THE 70IST MANUFACTURER. I. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI. BUILT UP MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR 5 1/4" WIDE MEMBERS. 10. NON-STRUCTURAL ELEMENTS A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND OTHER STRUCTURAL MOVEMENTS. B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED UNRESTRAINED UNLESS NOTED OTHERWISE. 11. GENERAL A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS. B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY. Monroe & Newell Engineers,Inc. P.O.Box 1597 70 Benchmark Road,Suitc 204 Avon,Colorado 81620 (970)9d9-7768 FAX(970)949-40_54 EMAIL avon@monroe-newell.com SKAAL HUS -UNIT 1 RENOVATION VAIL, EAGLE COUNTY, COLORADO NO.#9638 C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF HIS ITEMS. D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL, MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDED ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLED BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36. E. PROVIDE ASPHALTIC MASTIC-COATING ON ALL STEEI AND WOOD EXPOSED TO EARTH. F Ce � WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD CONDITIONS AND ARCHITECTURAL DRAWINGS. I. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER. F�` TITLE: GENERAL NOTES /,�5 � Z� °<y ��, DATE:09-16-2014 REVISION 9/26/14 SCALE:AS NOTED DRAWN BY:AVN S6 JOINT I 54.1 NEW L8X8X1/� OR NEW L8X8X3/8 LIIVTEL (RE: PLAN FOR SIZE) WITH I/�" � X 6" L_ EPDXY-ANGHOR AT I'-6" (LINTEL SHALL BEAR A MINIMUM OF 6" EAGH END ON SOLIDLY GROUTED. GMU) Monroe & Newell Engineers,Inc. P.O.Box 15J7 70 Benchmark Road,Suitc 204 Avon.Colorado S 1620 (970)949-7768 FAX(970)949-4054 EMAIL avon@monroe-newelLcom EXISTING INTERIOR GMU WALL i I i i � � NEW OPENING IN i i EXISTING WALL i i i � i � � � C � f Oi�l � �,��� _ ��-o„ SKAAL HUS -UNIT 1 RENOVATION VAIL, EAGLE COUNTY, COLORADO NO.#9638 EXISTING GMU WALL � � C T f 01�1 � � �,��� _ ��-o„ .f k��t�i. =_W I/4" X 8" X 8" TEEL PLATE WITH ?)-I/�" � X 4,� XPANSION ANGHOR T BEAM GENTER ND EAGH END EW WI�X50 BEAR N 6" WIDE GMU EARING SEAT �STALL SOL I D GROUT � WALL AT NORTH ND (LINTEL SHALL Ef�R A MINIMUM OF 6" EAGH END ON SOLIDLY CUROUTED. GMU) �v , 2 �- � � G� TITLE: FRAMING DETAILS DATE:09-16-2014 REVISION 9/26/14 C � J SCALE:AS NOTED DRAWN BY:AVN 1 /A� r � I� � � �� � NEW SIMPSON LU28 ' HANGER NEW W6X�5 STEEL BEAM WITH SOLID �X 1NOOD PAGiG BOTH SIDES WITH � � � � I �� I I/�" m THRU-BOLTS � I �l AT�'-O" I I/2" _ �'-O�� EXISTING ROOF SHEATHING � EXISTING ROOF JOISTJ NEW SIMPSON LU�B HANGER NEW W6X�5 STEEL BEAM WITH SOLID �X WOOD PAGiG BOTH SIDES WITH ��4 I/2" m THRU-BOLTS _ AT�'-O" EXISTING ROOF SHEATHING EXISTING ROOF JOIST 12 '--__._--� 2 NEW SIMPSON LU28 HANGER NEW W6X25 STEEL- BEAM WITH SOLID 2X WOOD PAGY BOTH SIDES WITH I/�" m THRU-BOLTS AT �'-O" FASGIA- MATGH 2 EXISTING I 3/4" X '7 I/4"— _'T--`� L�/L SUB-FASGIA ' ...■u�.u.:;. —_— I�981R��lfl��i�� ������ � � � C � f 01�1 2 I 1/�" _ �'-O�� Monroe & Newell SKAAL HUS -UNIT 1 RENOVATION Engineers,lnc. VAIL, EAGLE COUNTY, COLORADO P.O.Box 1597 - 70 Bcnchmark Road,Sui[c 204 Avon,Colorado 81620 (970)949-7768 FAX(970)949-4054 NO.#9638 EMAIL avon@monroe-newell.com HSS 3X3X1/4 AT �'-O" WITH I/4" X '7" X 7" STEEL END PLATE EAGH END WITH (�)-I/�" � LAG-BOLTS 5" � h N L N �� ��i�� � � C �i f Ol�l 3 I I/2" = I'-O" EXISTING ROOF SHEATHING EXISTING ROOF JOIST L8X4X3/8 X 6" STEEL SUPPORT ANGLE WITH (�)-3/4" m X 6" EXPANSION ANGHORS �A��-r�;�� r�' � 2v , �`� ��/ L TITLE: FRAMING DETAILS DATE:09-16-2014 REVISION 9/26/l4 SCALE:AS NOTED I DRAWN BY:AVN �• NEW 3" STONE PA�/ERS AND GROUT NEW WAT�R PROOFING AND PROTEGTION BOARD RE: ARGH. NEW 3/4" DEGiG SHEATHING ,. .. :��. \•. h ry � _ m NEW L�/L DEG� JOIST RE: PLAN I/4" X 6 I/�" X G I/4"- STEEL PLATE WITH (�J-5/8" � X 6.. EXPANSION ANGHORS � .r _ .� "12"I_ 5 I/4" �t' �NEW LVL BEAM ry RE: PLAN L6X4X3/8 X 4" BEAM SEAT WITH I/�" m X 4" LAG-BOLT AT 3" FROM END PLATE � � C � f O1�1 1 I I/�" _ �'—O�. Monroe & Newell SKAAL HUS -UNIT 1 RENOVATION Engineers,Inc. VAIL, EAGLE COUNTY, COLORADO P.O.Box 15)7 - 70 Bcnchmark Road,Suite 204 Avon,Colorado 81620 (970)949-7768 FAX(970)949-4054 NO.#9638 EMAIL avon@monroe-newell.com NEW 3" STONE PA�/ERS AND CUROUT NEW WATERPROOFING - AND PROTEGTION BOARD RE: ARGH. NEW DEGiG SHEATHING- J ..:`•:"��..•..:-: '. . t -------------- NEW '7 I/4" LVL DEG� JOIST WITH NEW SIMPSON HU7 HANGERS 3/8 WITH 3/4" � X 8" EXPANSION ANGHOR AT I'-O" � � � � I I/�" = I'-O" EXISTING GMU WALL �I � � jv � T�� ( G TITLE: FRAMING DETAILS DATE:09-16-2014 REVISION 9/26/t4 C� J SCALE:AS NOTED DRAWN BY:AVN 1 IA� rr I � _ � I/2"�. �.5,. 2 I/2" I/2" X 10" X 10" STEEL BASE PLATE WITH (2)-I/4" � X 4" EXPANSION ANGHOR 4" EXTERIOR GONGRETE SLAB-ON-GRADE WITH bXb W�.IXW2.1 W.W.F. � � � � � �I � � I I/�" = I'-O" Monroe & Newell SKAAL HUS -UNIT 1 RENOVATION Engineers,Inc. VAIL, EAGLE COUNTY, COLORADO P.O.Box 15)7 ' 70 Bc�chmark Road,Suite 204 Avon,Colorado 81620 (970)9a9-7768 FAX(970)949-4054 NO.#9638 EMAIL avon@monroe-newell.com HSS 3X3 GOLUMN RE: PLAN I" NON-SHRINK GROUT SLIP JOINT 10" X 10" GONG'i?ETE PIER WITH (4)-�4 �/ERTIGAL AND #3 TIES AT I'-4" (3)-�4 EAGH WAY �� RE � ��. •��- `�� � �-- TITLE: FOUNDATION DETAILS DATE:09-16-2014 REVISION 9/26/14 C '� rl J � SCALE:AS NOTED DRAWN BY:AVN NEW (4)-I/�" m BOLTS NEW STEEL SHI AS REQUIRED NEW HSS 3X3� GOLUMN WITH I/2" X8" X8" STEEL TOP PL AND (4)-I/2" m BOL TS Monroe & Newell Engineers,Inc. P.O.Box 1597 70 Benchmark Road,Sui[c 20� Avon,Colorado 81620 �y�o)9ay-��bx FAX(970)949-4054 EMAIL xvonQa monroe-newell.com � � � � � �I � � I I/�" _ �'-O,� SKAAL HUS -UNIT 1 RENOVATION VAIL, EAGLE COUNTY, COLORADO NO.#9638 WITH 3/8" EAGH SIDE 2X6 EXTERIOR STUD WALL WITH SHEATHING �X6 TREATED PLATE WITH I/�" m X 10" ANGHOR BOLT AT 3'-O" EXTERIOR PAVERS I I/�" RIGID— INSULATION 3" VOI D FORM �'-O.. I/�" ISOLATION - .101 NT INTERIOR BRIG� PA�/ERS #5 AT I'-4" X 2._6�� ��i x°�z °x—: I ���I I/�" � GLR. _� 11=1 II�;�II ��3)-�6 TOP AND — BOTTOM AND #3 TIES AT I'-O" (EPDXY 8" DOWEL TOP AND BOTTOM BARS 6" INTO EXISTING SIDE WALLS) � � � � 3/4" = I'-O" �I � � i i i j�---REMO�/E EXISTING i STUD WALL i i i i Ii ::f�i-°11\i� TITLE: FOUNDATION DETAILS �o .. Z� ~ � DATE:09-16-2014 REVISION 9/26/14 C � ■ ■ J �l SCALE:AS NOTED DRAWN BY:AVN _... �.v-.,...�_... � �..�:�,4.�. _�.0�.�:���..�.���._.�.�,.�4�.�r w�..�.�. �..����.e�....�.., . _ _. . _�. _ � � � . ,_. . . _ r _ ♦ ��/7�' �!'I� � �YOYtZG �x :��rer � � � Job Name: Skqal Hus Unit 1 Customer: Marce[lo Reyes Engineer. Salesman: Address: 141 Wesfi Meadows City: Vail State: CO Zip: � Phone: , lndoor Design Temperature: 70.0 F Outdoor Design Temperdture:-20.0 System Design Water Temperature: i 80.0 F HEAT L055 C/�LCULP�TIDNS � 1st FEoor k Master Bedro F2oom Height(ft) 8.00 Room Length(ft} 21.Q0 Room Width(ft} 13.25� Doors&Glass{sq ft} 135.00 Door&Glass Factor 0.350Q Exposed Wall Length(ft) 32.00 Exposed Wall Factor 0.0700 Co[ci F'artition Length(ft) Cold Partition Factor Cei[ing Factor ' F}oor Factor 0.0400 Infiltration Factor 0.0120 fndoorTemperature(F) 70.00s Heat Loss(BTU/HR) 8,421 B�SEBO�RD S�LECT[ON� 1st F[oor Bathroom 8.00 7.33 '!1.00 91.00 0.3500 11.00 0.0700 Fine/Line 15{lin.ft.) selecfed FinelLine 30(lin.ft.} selected MuItilPak 80(iin.ft.) selected BaselLine 70{lin.ft.) selecfed BaselLine 200U(lin.ft.) selecfed -9- Copyrighi(C)2000-2004 S1aniJFin Co �/���� J � 0.0400 0.0120 70.00 2,000 n Floor Tota[s � Job Totals 1 100 Forest Drive NY 11548 0 484-2600 www.slantfin.corn r . � i �/c'��� %�� � �YOYi2G �x �..;�-r'er � p . Job Name: Skaal Hus Unit 1 Customer: Marcello Reyes Engineer: Salesman: Address: 141 West Meadows City: Vail State: CO Zip: Phone: _ Indoor Design Temperaiure: 70.0 F Outdoor Design Temperature: -20.0 System Design Water Temperature: 180.0 F H�aT LOSS CaLCULATI0N5 2nd Floor � Bedroom 1 Room Height(ft) $.00 Room Length(ft) 10.75 Room Width(ft) 11.46 Doors�G[ass(sq ft) 32.25 Door&Glass Factor Q.3500 Exposed Wall Length(ftj 22.00 Exposed Wall Factor Q.0700 Co1d Partition Length(ft) Cotcf Partition Factor Ceiiing Factor 0.0700 F1oor Factor 0.0400 Infittration Factor 0.0'180 I Indoor Temperature(F) 70.00 Neaf Loss{BTU/HR} 4,723 B/�S�BOARD SEL�CTIONS 2nd F[oor Fine/Line 15(lin.ft_) selecfed Fine/l.ine 3Q{lin.ft.) selecfed MultilPak 80(lin.ft.) selecfed Base/Line 70(3in.ft.) se/ecfed ; Base/Line 2000(Iin.fL) , selec#ed -2- Copyright(C} 200d-2004 SlanfJFin Bath room s.00 6.25 8.38 11.25 0.3500 6.25 0.0700 0.0700 0.0400 0.012Q 70.00 1,726 Bedroom 2 8.00 11.30 s.�3 21.00 0.3500 9.19 a.a7aa 0.0700 O.Q400 0.012� 70.OQ 2,905 Floor 7otals � Job Totals 100 Forest Drive 9,354 ree 35,831 7 6) www.slantfin.com r / r'N ,/r��� �i7� � G�YOYtZG ��C 'c-��'�rer � � p � � Job Name: Skaal Hus Unit 1 Customer: Marcello Reyes Engineer: Salesman: Address: T41 WestMeadows City: Vail State: CO Zip: Phone: ` Indoor Design Temperature: 70.0 F Oufidoor Design Temperature: -20.0 System Design Water Temperaivre: 180.0 F H�f�T L455 CALCUL�7ION5 3rd Floor , Living; �loor Totals Job Totais Room Height(ft) 8.00 Room Length(ft) 29.00 Room Width(ft} 13.25 Doors 8�Glass{sq 4k) 225.25 Door 8�Glass Factor 0.3500 Exposed Watl Length(ft) 55.50 Exposed Wall Factor 0.0700 Co1d Partition Length(ft) Cold Partition Factor Ceiling Factor 0.0500 Floor Factor 0.0400 Infittration Factor 0.0270 lndoor Temperature{F) 70.00 Heaf Loss(BTU/HR} 19,056 B�S�BDAI�D SELECTIONS 3rd Floor Fine/Line 15(lin.ft.} selected FinelLine 30(lin.ft.) selected Multi/Pak 80(1in,ft,) selected SaselLine 70(lin,ft.) selecfed BaselLine 2000(lin.ft.} se/ecfed 3- Copyright(C}2( SIanUFin Corpo 19,056 n 100 Forest Drive 0 NY 11548 {S16) 484-2600 www.slantFin.com �i-._ � �II�� Skaal Haus Unit #1 ���?Fi�t;;,i�,p r 4��K� ��� Demand Load Calculations ;'�`' fiy� �-f�s r'�� �v �; � �:�_'��:� (Per NEC Article 220 Parts I-III) _�'��� � �, 13 7 `� .� ` , �: � ���� �eral �t�'��vr�ti.��z�� ����� Dwelling unit Square footage General & Lighting (1st 3 KVA) General & Lighting (Remainder) :hen Small Appliances Refrigerator Dishwasher Oven/Range (Re:table220.19) M icrowave Disposal ndrv &Spa Appliances Clothes Washer Clothes Dryer Jacuzzi Tub :hanical Equipment Mechanical heating equipment Electric heater Add'I 25% Max Motor Load uantit 1200 1000 SF X 200 SF X 2 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 EA X 1 LS X Volt-Amps 3 X 3 X 1500 X 1000 X 1200 X 8000 X 1200 X 1000 X 1000 X 5000 X 1500 X 1500 X 1500 X 1500 X For 208V, 1-Phase, 3 Wire Service 24210 (VA) / 100 amp single phase service ional Calc per NEC 220.82 General Load Connected 29500 1 st 10 kVA of General Loads 1 LS X 10000 X Remainder of General Loads 1 LS X 19500 X Heating/AC Load 1 LS X 0 X For 208V, 1-Phase, 3 Wire Service 17800 (VA) / 100 amp single phase service Demand 100% _ 35% _ 35°/a = 75% _ 75% _ 80% _ 75% _ 75% _ 75% _ 100% _ 75% _ 100% _ 100% _ 25% _ TOTAL 208 100% 40% 100% TOTAL 208 = � 3000 210 1050 750 900 750 750 5000 1125 1500 1500 375 24210 116 AMPS 10000 7800 0 1 86 AMPS �v � 2� — �`f GG" � � PANEL UNIT 1 PROJECT: 14060 ENGINEER: SOH PROJECT#: SKAAL HAUS UNIT 1 VOLTAGE: 120/208V, 1 P, 3W MOUNTING: RECESSED MAINS: 100 A MCB TYPE: QO RESIDENTIAL AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION BALLET 900 15 1 1 2 1 15 1500 KITCHEN OUTLET LIVING RM CLOSET 1200 20 1 3 4 1 15 1500 KITCHEN OUTLET HEATER 1000 15 2 5 6 1 20 1200 LOW HALLBATH 1000 7 8 1 15 1200 BOILER AND PUMPS SPACE 0 9 10 1 15 1200 BATHROOM MID DRYER 2500 30 2 11 12 1 20 1200 BED & HALL 2500 13 14 1 20 1200 DISHWASHER DISP HEAT TAPE AT PORCH 500 15 1 15 16 2 50 4000 RANGE JETTED TUB 750 30 2 17 18 4000 GFI 750 19 20 0 SPACE 0 21 22 0 0 23 24 0 0 25 26 0 0 27 28 0 0 29 30 0 0 31 32 0 0 33 34 0 I 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY NOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS AS REQUIRED BY COI X�d�x�.�� CALCULATED POWER FACTOR: RELOCATE PANEL TO NEW LOCATION, REWORK EXISTING FEEDERS & CIRCUITS. „�."��'����''�T#�, 0.98 ADD NEW JETTED TUB `� � ��� t"' � ,.� �� �'�, P:; CONNECTEDLOAD CONNECTED AMPS DEMANDLOAD DEMAND AMPS `' -�- �y4 *- . , APPLIANCES 0 0 0 0 � ��' LIGHTING & RECEPT. 11400 55 5940 29 � � � MECHANICAL 3700 18 4200 20 ��r'���r����r����`'�,;��� KITCHEN OVEN & DRYER 13000 63 13000 63 �'"��:$����'�' TOTAL 28100 135 23140 See demand load calculation 9/26/2014