HomeMy WebLinkAbout15. B13-0034 reissued permitNOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
m~
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT
Job Address: 3080 BOOTH FALLS CT VAIL
Location ...... : UNIT B (SOUTH UNIT)
Parcel No ..•. : 210102301020
OWNER WINDSURFER LLC 03/15/2013
PO BOX 1644
DUXBURY
MA 02331-1644
Permit#:
Project#:
B13-0034
PRJ12-0705
Applied ..... : 03/15/2013
07/09/2014 Issued ... :
APPLICANT PETE DOBYNS (DBA WINDSURFER 03/15/2013 Phone: 617-908-1647
PO BOX 1644
DUXBURY
MA 02331
CONTRACTOR STYERS, INC. 04/11/2013 Phone: 970-618-4815
ALAN C. STYERS
PO BOX678
SNOWMASS
co 81654
License:C000003753
Description:
NEW CONSTRUCTION OF A DUPLEX -includes snowmelt to driveway
Occupancy: R-3 Type Construction: VB Valuation: $1,089,000.00
******************•************************************************************** FEE SUMMARY *******************************************************************************
Building Permit ----------->
Electrical Permit --------->
Mechanical Permit ------>
Plumbing Permit -------->
$4,288.25 Bldg Plan Check---------->
$483.00 Elec Plan Check ----------->
$480.00 Mech Plan Check--------->
$1,260.00 Plmb Plan Check--------->
$2,787.36
$313.95
$120.00
$315.00
Use Tax Fee----------------------->
Restuarant Plan Review-------->
Additional Fees-------------------->
Recreation Fee-------------------->
Investigation----------------------->
Will Call------------------------------>
TOTAL PERMIT FEES---------->
Payments------------------------------->
BALANCE DUE---------·······-------->
$21,580.00
$0.00
$7,069.82)
$742.50
$0.00
$20.00
$25,540.24
$55,126.05
29,585.81)
*************************************•********************************************************""***************************************************************************************
DECLARATIONS
I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and
other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149
OR AT OUR OFFICE FROM 8:00AM -4:00 PM.
combination permit_012811
***********************************************************************************************************************************'**************************************************
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Perm it #: B 13-0034
Owner: WINDSURFER LLC
UNIT B (SOUTH UNIT)
Address: 3080 BOOTH FALLS CT VAIL
Location:
*************************************************************************************************************************************************************************************
combination permit_012811
*****************************************************************************************************************************************************
REQUIRED INSPECTIONS AND STATUSES
Permit#: B13-0034
Owner: WINDSURFER LLC
UNIT B (SOUTH UNIT)
Address: 3080 BOOTH FALLS CT VAIL
Location:
*****************************************************************************************************************************************************
Item: 00010 BLDG-FOOTING
05/31/2013 By: Martin Action: CR Comments: See
B 13-0033 for corections
06/05/2013 By: sgremmer Action: AP
Item: 00020 BLDG-Foundation/Steel
07/02/2013 By: sgremmer Action: AP
Item: 00021 PLAN-ILC Foundation Plan
11/22/2013 By: Warren Action: AP
Item: 00110 ELEC-Service
08/19/2013 By: sgremmer Action: AP
Item: 00120 ELEC-Rough
08/07/2013 By: sgremmer Action: PI Comments:
service laterals
11/21/2013 By: sgremmer Action: PI Comments:
soffits
12/31/2013 By: sgremmer Action: DN Comments:
notch plate and secure romex where required by code
ufer ground be installed where it is protected
01/06/2014 By: sgremmer Action: AP
Item: 00200 MECH-Rough
08/26/2013 By: sgremmer Action: PI Comments:
lower level infloor heat
11/20/2013 By: JRM Action: PI Comments: SNOW
MELT ENTRY 100 #AIR TEST
12/11/2013 By: sgremmer Action: PI Comments:
infloor heat and boiler flues
02/05/2014 By: sgremmer Action: AP
03/12/2014 By: sgremmer Action: AP Comments: deck
snow melt
06/03/2014 By: sgremmer Action: AP
Item: 00210 PLMB-Underground
08/06/2013 By: sgremmer Action: DN Comments: not
on test
08/07/2013 By: sgremmer Action: AP
Item: 00220 PLMB-Rough/D.W.V.
12/12/2013 By: shane Action: AP
12/19/2013 By: Martin Action: DN Comments:
plumbing in exterior wall cavity causes need for
revision to insulation. Air test ok
02/05/2014 By: sgremmer Action: AP
Item: 00230 PLMB-Rough/Water
12/19/2013 By: Martin Action: DN Comments:
Plumbing against exterior wall, insulation to be
addressed
02/05/2014 By: sgremmer Action: AP
Item: 00240 PLMB-Gas Piping
12/12/2013 By: shane Action: AP
combination permit_012811
07/31/2014 By: sgremmer Action: AP Comments: new
boiler
Item: 00310 MECH-Heating
02/05/2014 By: sgremmer Action: AP
Item: 00320 MECH-Exhaust Hoods
02/05/2014 By: sgremmer Action: AP
Item: 00022 PLAN-ILC FRAMING
11/22/2013 By: Warren Action: AP
Item: 00030 BLDG-Framing
10/17/2013 By: sgremmer Action: PI Comments:
sheathing
11/21/2013 By: sgremmer Action: PI Comments:
soffits
02/05/2014 By: sgremmer Action: DN Comments:
Bearing for double L VL at Roof in living room
grout connections for steel columns
missing bolt at plate in lower south corner
06/18/2014 By: sgremmer Action: AP
Item: 00050 BLDG-Insulation
02/17/2014 By: mdenney Action: AP
Item: 00060 BLDG-Sheetrock Nail
09/16/2013 By: sgremmer Action: PI Comments:
party wall
03/12/2014 By: sgremmer Action: DN Comments: not
complete, fire needs to sign off garage and shared
unit wall
06/18/2014 By: sgremmer Action: AP
Item: 00070 BLDG-Misc.
12/03/2013 By: sgremmer Action: PI Comments: lath
01/03/2014 By: JRM Action: AP Comments:
LATHE AND NAIL BASE
07/07/2014 By: sgremmer Action: AP Comments:
U-values
Item: 00190 ELEC-Final
07/08/2014 By: sgremmer Action: DN Comments:
breaker blanks and label exterior panel board
finish exterior elextrical
GFCI for attic
Disconnect for 240 steamer
07/17/2014 By: sgremmer Action: PI Comments: All
complete except new boiler
07/30/2014 By: sgremmer Action: AP
Item: 00290 PLMB-Final
07/08/2014 By: sgremmer Action: DN Comments:
vacuum breaker for hose bib in mech room
valve for BBQ gas pipe
paint exterior gas pipe
hammer arrestor at all quick closing valves
07/17/2014 By: sgremmer Action: AP
Item: 00390 MECH-Final
07/08/2014 By: sgremmer Action: AP
07/17/2014 By: sgremmer Action: PI Comments: All
complete except new boiler
07/30/2014 By: sgremmer Action: AP
Item: 00534 PLAN-FINAL C/0
07/17/2014 By: Warren Action: NR Comments:
Planning inspection not requested but scheduled.
Final plumbing was requested.
07/24/2014 By: Warren Action: DN Comments:
Install straw tubes, top soil in eroded areas, remove
scaffolding and heaters.
07/28/2014 By: Warren Action: AP
Item: 00091 PW-Final driveway grade
combination permit_012811
07/16/2014 By: Is Action: AP
Item: 00539 PW-FINAL C/0
07/16/2014 By: Is Action: DN Comments: Not
Ready
07/25/2014 By: Is Action: AP
Item: 00540 BLDG-Final C/0
06/26/2014 By: Martin Action: PI Comments:
Blower Door test approved
07/08/2014 By: sgremmer Action: DN Comments:
Plans in revision for boiler and snow melt
Planning, fire, and PW to sign off
rear stair max 7 3/4" riser max 3/8" differance
between risers
handrail for 4 or more risers
guardrail at rear landing that is over 30"
07/30/2014 By: sgremmer Action: PI Comments: TCO
need to finish boiler
combination permit_012811