Inspection Checklist
Energy Code: 2012 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Gomments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions. �
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.6 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not
[PR2]z on loads calculated per ACCA Coolin Coolin
Manual J or other methods g' g� ❑Not Observable
approved by the code official. Btu/hr Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Antlers #106 Report date: 11/11/14
Data filename: Page 2 of 5
2012 IECC Foundation Inspection Complies? Comments/Assumptions
403.8 Snow-and ice-melting system controls ❑Complies
[F012]z installed. ❑Does Not
_ ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Antlers #106 Report date: 11/11/14
Data filename: Page 3 of 5
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
403.2.1 Supply ducts in attics are R- R- ❑Complies
[FR12]1 insulated to >_R-8.All other ducts R_ R_ ❑Does Not
in unconditioned spaces or
��' ❑Not Observable
outside the building envelope are
insulated to >_R-6. ❑Not Applicable
403.2.2 All joints and seams of air ducts, ❑Complies
[FR13]1 air handlers, and filter boxes are ❑Does Not
sealed.
_ ❑Not Observable
❑Not Applicable
403.2.3 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
_. ❑Not Observable
❑Not Applicable
403.3 HVAC piping conveying fluids R- R- ❑Complies
[FR17]z above 105 °F or chilled fluids ❑Does Not
below 55°F are insulated to ?R-
_ 3 ❑Not Observable
❑Not Applicable
403.3.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.4.2 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
- ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Antlers #106 Report date: 11/11/14
Data filename: Page 4 of 5
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 cfm/100 ft2 across the system or ftz ftz ❑Does Not
<=3 cfm/100 ft2 without air
'� handler @ 25 Pa. For rough-in ❑Not Observable
tests, verification may need to ❑Not Applicable
occur during Framing Inspection.
403.2.2.1 Air handler leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F19]z installed on forced air furnaces. ❑Does Not
_ ❑Not Observable
❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]z on heat pumps. ❑Does Not
_ ❑Not Observable
❑Not Applicable
403.4.1 Circulating service hot water ❑Complies
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
_ ❑Not Observable
❑Not Applicable
403.5.1 All mechanical ventilation system ❑Complies
[F125]z fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. ❑Not Observable
❑Not Applicable
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
� Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
_ ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Antlers #106 Report date: 11/11/14
Data filename: Page 5 of 5
2012 IECC Energy
Efficiency Certificate
. -
Above-Grade Wall 0.00
Below-Grade Wall o.00
Floor 0.00
Ceiling / Roof 0.00
Ductwork (unconditioned spaces):
�.. . .
Window
Door
.. . . -
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments