Loading...
HomeMy WebLinkAboutB14-0457 ResCheck Generated by REScheck-Web Software Com pl ia nce Certificate Project Antlers #106 Energy Code: 2012 IECC Location: Eagle County, Colorado Construction Type: Multi-family Project Type: Alteration Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: . . : � . ..- . .- -. Project Title: Antlers #106 Report date: 11/11/14 Data filename: Page 1 of 5 REScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Gomments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. � 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not [PR2]z on loads calculated per ACCA Coolin Coolin Manual J or other methods g' g� ❑Not Observable approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Antlers #106 Report date: 11/11/14 Data filename: Page 2 of 5 2012 IECC Foundation Inspection Complies? Comments/Assumptions 403.8 Snow-and ice-melting system controls ❑Complies [F012]z installed. ❑Does Not _ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Antlers #106 Report date: 11/11/14 Data filename: Page 3 of 5 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR12]1 insulated to >_R-8.All other ducts R_ R_ ❑Does Not in unconditioned spaces or ��' ❑Not Observable outside the building envelope are insulated to >_R-6. ❑Not Applicable 403.2.2 All joints and seams of air ducts, ❑Complies [FR13]1 air handlers, and filter boxes are ❑Does Not sealed. _ ❑Not Observable ❑Not Applicable 403.2.3 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not _. ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]z above 105 °F or chilled fluids ❑Does Not below 55°F are insulated to ?R- _ 3 ❑Not Observable ❑Not Applicable 403.3.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.4.2 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not - ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Antlers #106 Report date: 11/11/14 Data filename: Page 4 of 5 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.2.2 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ftz ftz ❑Does Not <=3 cfm/100 ft2 without air '� handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.2.2.1 Air handler leakage designated ❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [F19]z installed on forced air furnaces. ❑Does Not _ ❑Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]z on heat pumps. ❑Does Not _ ❑Not Observable ❑Not Applicable 403.4.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. _ ❑Not Observable ❑Not Applicable 403.5.1 All mechanical ventilation system ❑Complies [F125]z fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. � Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating ❑Does Not systems have been provided. _ ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Antlers #106 Report date: 11/11/14 Data filename: Page 5 of 5 2012 IECC Energy Efficiency Certificate . - Above-Grade Wall 0.00 Below-Grade Wall o.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork (unconditioned spaces): �.. . . Window Door .. . . - Heating System: Cooling System: Water Heater: Name: Date: Comments